34
radio frequency, high voltage and custom reed relays

radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

radio frequency, high voltage and custom

reed relays

Page 2: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

radio frequency, high voltage and custom

reed relays

radio frequency, high voltage and custom

reed relays

Page 3: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

our aim is

to form closepartnerships withour customers,working withthem at all levels

Crydom Magnetics Limited, an ISO9001

registered production facility based in

Wimborne, England, has been set up as

CrydomÕs centre of excellence for reed switches

and relays, liquid level, flow, proximity sensors

and transformers.

The company has been manufacturing reed switch and coil

based products for over thirty years. This site is equipped with

a state-of-the-art class 100 clean room facility, supplying high

quality reed switches into many of CrydomÕs reed-based

products. This ensures that Crydom controls production,

delivery and above all else, quality.

The companyÕs objective is to achieve profitable growth every

year by providing high quality products, backed by innovative

engineering and quality driven manufacturing processes.

With design, development and manufacturing under one roof,

our aim is to form close partnerships with our customers,

working with them at all levels from early feasibility studies to

delivering production quantities.

markets.

For further details visit the Crydom Magnetics

website at www.crydom.co.uk.

In order to achieve this, Crydom have established a team of

Agents and Distributors world-wide to service customer

requirements in local

Page 4: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

radio frequency reed relays (DC to 30MHz)Developed from Crydom’s expertise in high vacuum RF reed switches, the RF

Reed Relay range offered today is a result of many years research and

development, working with the worldÕs top HF radio system manufacturers. With

relay solutions to suit all HF applications requiring voltage isolation up to 9kV and

carry currents up to 20Amps (RMS at 30MHz), Crydom has the engineering

expertise and experience to meet your exacting requirements.

Crydom Magnetics is unique in the industry as being a manufacturer of RF

vacuum reed switches and reed relays, not a relay manufacturer primarily

packaging other company’s reed switches. As a result, Crydom have full control

of the whole RF reed relay product ensuring the best in performance and quality.

A wide range of Crydom standard designs are offered with many coil screening

options to suit performance requirements and budgets. Two new miniature RF

reed relay designs are introduced for the first time. The 4 Series offers a low

cost and flexible package in all popular contact and coil configurations and

the 5 Series extends the RF performance with the first fully screened

miniature coil assembly offering ultra-low RF losses.

high voltage reed relaysCrydom’s 30 year experience in manufacturing high vacuum reedswitches

is prominent with the D and S-Series High Voltage Reed Relays. Capable

of withstanding up to 15kV DC, the D-Series High Voltage Reed Relay is

suitable for high reliability applications such as cardiac defibrillators, cable,

transformer and semiconductor test applications as well as high voltage

power supplies. New mounting and electrical connection options are now offered

alongside the popular PCB ‘through-hole’ relay.

If PCB space is at a premium, the miniature S Series High Voltage Reed Relay

is available in a 30mm size package. Capable of isolating up to 5kV DC, the

S Series was developed specifically for the

high voltage ATE market, where size,

performance and reliability are paramount.

custom reed relaysIf the products featured in this catalogue

do not quite meet your application requirements, please contact us. Having

supplied many hundreds of relay designs to the marketplace over the last

20 years, Crydom are geared towards providing custom RF, high voltage

and general purpose reed relays, drawing on standard, readily available

components, thus minimising development costs. A Custom Relay Selector is

provided on page 26 to help you specify your requirements. Please fill in and

return the form and we will be pleased to consider your specifications.

Alternatively fill in the on-line form at www.crydom.co.uk

radio frequency,high voltageand custom

reed relays

ISO 9001 registered

productionfacility, high

voltage & radiofrequency reedrelays for over

thirty years

Page 5: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

selector guideradio frequency reed relays

Page

FRD12000 Series 8-9

Screened. 8kV, 6A

FRD13000 Series 10-11

Fully Screened. 9kV, 6A

FRD30000 Series 12-13

Fully Screened. 6.5kV, 20A

FRS12000 Series 14-15

Miniature Single RF

FRS22012 18-19

Fast Latching, Screened. 3.5V, 1.5A

4 Series 20-21

Screened. 3.5kV, 3.5A

6 Series 22-23

Fully Screened. 3.5kV, 4A

S Series 26-27

15kV, 50W

custom products

Application Notes 7

Custom Relay Selector 32

Dip Series 28-29

Sip Series 30-31

dip and sip reed relays

high voltage reed relays

D Series 24-25

15kV, 50W

FRS12000 Series 16-17

Screened. 2kV, 5A

Page 6: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

General

Contact ArrangementRelays manufactured by Crydom have one of the following contactarrangements:

Form A : Normally open - energise to close contactsForm B : Normally closed - energise to open contactsLatching : Contact is bistable - energise ÒsetÓ coil to close

contacts; energise ÒresetÓ coil to open contacts

Coil SuppressionIt is recommended that all relay coils be suppressed by a diode. Thisis essential for latching relays. Operate and release times for therelays are quoted with coil suppression fitted.

Soldering & CleaningCrydomÕs reed relays are high performance products and thematerials and methods of construction are significant factorsin achieving performance specifications. The following guidelinesshould therefore be followed when adopting assembly, soldering andcleaning processes:

1) Soldering. Crydom propose that either low residue fluxes areused in the soldering process (to eliminate the need for cleaning),or that the reed relays are fitted onto the PCB after the cleaningprocess has taken place. If a solder bath is employed themaximum immersion time recommended is 10 seconds at 250¡Cor 3 seconds at 350¡C.

FRD12000/13000 Series: Electrical connection to the contacts ofthe FRD12000/13000 Series relay is via the reedswitch leadout.Care must be taken when hand soldering, as physical andthermal shocks can damage the glass to metal seals. A thermalshunt (aluminium clamp) carefully applied to the reedswitchleadout, adjacent to the glass seal will reduce the chances ofbreakage due to thermal shocks.

Alternatively, the relays should be warmed prior to soldering.

2) Cleaning. It is impossible for Crydom to offer blanket approval ofmethods, due to the many and varied automatic cleaning systemsnow available to conform to recent legislation.

If, after the soldering process, the customer wishes to clean PCBÕscontaining Crydom reed relays then the use of post operativecleaners such as IPA or HCFC based solvents with low pressurebrush applicators is recommended. Any customer wishing to usean alternative cleaning system should ensure that the fluids andprocesses are appropriate for application on Crydom reed relays.CrydomÕs devices are not hermetically sealed and as such,exposure to certain fluids can result in the degradation of therelay materials and subsequently a reduction in the electricalperformance. Please contact Crydom for further information onthe suitability of various cleaning solutions.

High Voltage Reed Relays

The principal function of a high voltage reed relay is to isolate as higha voltage as possible. In order to achieve this all Crydom high voltagereed relays employ evacuated reed switches. These switches areavailable with either Tungsten or Rhodium contacts depending uponthe switching characteristics required. As with all reed relays theyare susceptible to mutual magnetic interference when mountedin close proximity to each other. These parameters are discussed ingreater detail below.

Isolation VoltageThe isolation voltages specified correspond to DC or AC peak. Atmains frequencies (e.g. 50 or 60Hz) the two may be considereddirectly equivalent.

Contact Material - Rhodium vs TungstenRhodium contacts should be used where very low contact resistanceis required or when power switching at <1000V is undertaken.Tungsten contacts perform best when switching high voltages (1-10kV) at very low current. It should be noted that switchingpower will reduce relay operating life - the factory should becontacted for advice on specific applications.

Magnetic ScreeningCrydom high voltage reed relays are generally supplied withmagnetic screening fitted. However, this is not absolute and so, if theminimising of interference is critical, the mounting configuration infigure 1 below is recommended.

6

application notes

Figure 1 : Recommended Mounting for ‘S’ and ‘D’ Series High Voltage Reed Relays

Page 7: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

RF Reed Relays

The basic requirements of RF reed relays are to provide minimal RFsignal loss and very low contact resistance over a long operatinglifetime. This is achieved in Crydom RF reed relays through the use ofcopper plated reed switches with Rhodium contacts in conjunctionwith carefully designed coil assemblies. They are intended for useacross the frequency range 1-30MHz and typical RF parameters foran RF reed relay across this band (measured in a 50 Ohm system) areshown in figure 2 below:

Particular to RF reed relays are the effects of RF and magneticscreening and these are discussed in more detail below. Also, highvoltage isolation considerations are specific to RF conditions.

RF ScreeningWhen an RF current is passed through the switch of a reed relay anelectromagnetic coupling between reed switch and coil results in someenergy being dissipated in the coil. This dissipation manifests itself asan addition to the effective series resistance (ESR) of the relay and, atcurrents of several amps, heating of the relay coil. RF coil heating isgreatest at high frequencies and varies in proportion to the square ofthe RF current carried in the switch. It is this factor which limitsmaximum carry current at high frequencies and ambient temperatures.The purpose of RF screening is to reduce these losses and extendrelay performance at high frequencies and high ambient temperatures.

Crydom RF reed relays are available with no screening, partialscreening and full RF screening of the coil, depending upon therequirements of the application.

Relays without an RF screen have restricted current carryingcapability at high ambient temperatures and frequencies (and ahigher associated ESR). However, this suits many typical ATUapplications well, as the highest currents occur only at the lowerfrequency bands (e.g. 2MHz).

Relays with partial RF screening have extended current carryingperformance at elevated ambient temperatures over unscreenedvariants.

Relays with full RF screening represent the ultimate in low loss RF reedrelay design. The ESR and resulting coil heating are significantly lowerthan for other types and this makes them suitable for applicationsin high ÒQÓ circuits where high currents are present over the wholefrequency range.

As an illustration of the effect of relay screening on ESR,measurements taken under load at 30MHz (i.e. the worst casefrequency) are shown in figure 3 below for fully, partially andunscreened ÒFRDÓ series reed relays.

Magnetic ScreeningWhen power is supplied to the coil of a reed relay a magnetic field isproduced. When relays are mounted in close proximity this can resultin mutual magnetic interference. However, Crydom RF reed relaysare generally not fitted with magnetic screens, as the presenceof ferromagnetic material around the coil can adversely affect ESRand RF coil heating as described above. For applications whererelays are mounted in close proximity the recommended mountingconfiguration is shown in figure 4 below.

Isolation VoltageAll withstand voltages are specified and tested at DC. However, highvoltage breakdown mechanisms at high frequency differ to those atDC. In general, breakdown across the reed contacts occurs at ahigher RF peak voltage than DC. Conversely, breakdown outside theswitch (e.g. switch to coil or screen), caused by surface tracking, canoccur more readily at high frequency than at DC. Verification of anyparticular voltage and frequency combination can be undertaken byCrydom upon request.

Figure 2 : Typical Parameters of Crydom RF Reed Relays

Figure 3: Effects of screening on ESR

Figure 4 : Mounting Configurations to Minimise Magnetic Interference ( *Note Orientation)

7

Page 8: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

Up to 8kVDCIsolation

6A CarryCurrent (up to 30MHz)

Excellent RFPerformance

Ideal forAntenna TuningUnits

Form A/BContactConfiguration

CustomisingFacility

8

FRD12000 Series Screened. 8kV, 6A

The FRD12000 series was one of Crydom’s first RF reed relay designs. With 8kV(DC) withstand voltage and 6A (30MHz) carry current capability, the FRD12000series has satisfied countless HF radio system specifications over the years,finding applications in commercial maritime (GMDSS) equipment and military HFradio units worldwide.

COIL at 20¡C

Nominal Working Voltage VDC 24 12 12 24

Must Operate VDC max 15 8 8 14

Must Release VDC min 2 2 2 4

Nominal Resistance ohms +/10% 1000 380 340 1500

RF Screening Part - Part -

RF Screening Connection pin position 1 & 4 1 & 4

Coil Connections pin position 2 & 3 2 & 3 2 & 3 2 & 3

RELAY

Operate time (including bounce) ms 2 3 3 3

Release time ms 1 2 1 2

Isolation contact to all

other terminals kV DC max 10 10 10 10

Isolation coil to screen kV DC max 0.5 N/A 0.5 N/A

Capacitance contact to

all other terminals pF contacts open 2.0 2.5 2.0 2.5

ENVIRONMENTAL

Storage temperature range ¡C -55 to +125

Operating temperature range ¡C Limited current* -40 to +85

Shock g 11ms 1/2 sine pk 100

Bump g 6ms 1/2 sine pk 40

Vibration g 10- 500Hz 10

*see graphical data

CONTACT UNITS CONDITIONS FRD12015 FRD12021 FRD12014 FRD12049

Action (form A, B or Latching) A B A B

Switching Voltage V DC max 20 20 20 20

Switching Current A DC max 1 1 1 1

Carry Current A RMS max 6 6 6 6

Isolation kV DC max 8 8 8 8

Capacitance pF coil/screen gnd 0.4 0.6 0.4 0.6

9Lifetime operations dry switching 10 109 109 109

Contact Resistance mOhms maximum (typical) 50 (15) 50 (15) 50 (15) 50 (15)

Insulation Resistance Ohms minimum (typical) 1010(1013) 1010 (1013) 1010 (1013) 1010 (1013)

ESR at 4.5A, 30MHz mOhms typical 100 150 100 150

CONTACT US NOW

UNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 9: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

9

MECHANICAL

Available with either 12 or 24V coils, in both form A and B contactconfigurations, this proven design is fully approved to MIL standards ofbump, shock and vibration and features one of Crydom’s in-housemanufactured, high vacuum reed switches for unsurpassed RFperformance and reliability.

Offering a cost effective alternative to vacuum ceramic relays, theFRD12000 Series RF Reed Relay has a greater lifetime, imperative forfrequency hopping systems. As well as HF radios, the FRD12000 Serieshas also found applications in electromedical, sonar and test equipment,which require high isolation and inherent reliability.

radio frequency reed relays

Page 10: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

10

● New FullyScreened Coilfor Low RF Loss

● Up to 9kVDCand 6A at30MHz

● Drop-inreplacement forFRD12000Series

● Ideal forAntenna TuningUnits

● CustomisingFacility

FRD13000 SeriesFully Screened. 9kV, 6AA development of the FRD12000 series, this design has a complete RF screenaround the coil assembly, offering a very low loss transmission path. This resultsin better carry current performance at elevated temperatures. This device alsofeatures an anti-corona sleeve shrouding the reed switch contact for improvedpeak RF voltage isolation.

COIL at 20°C

Nominal Working Voltage VDC 24 24

Must Operate VDC max 15 16

Must Release VDC min 3 3

Nominal Resistance Ohms +/10% 900 900

RF Screening Full Full

RF Screening Connection pin position 1 & 8 1 & 8

Coil Connections pin position 4 & 5 4 & 5(+)

RELAY

Operate time (incl. bounce) mS 2 1

Release time mS 1 2

Isolation contact to all other terminals kV DC max 9 9

Isolation coil to screen kV DC max 0.5 0.5

Capacitance contact to all other terminals pF contacts open 1.5 1.5

ENVIRONMENTAL

Storage temperature range °C -55 to +125

Operating temperature range °C Limited current* -40 to +85

Shock g 11ms 1/2 sine pk 100

Bump g 6ms 1/2 sine pk 40

Vibration g 10- 500Hz 10

*see graphical data

CONTACT UNITS CONDITIONS FRD13503 FRD13504

Action (form A, B or Latching) A B

Switching Voltage V DC max 20 20

Switching Current A DC max 1 1

Carry Current A RMS max 6 6

Isolation kV DC max 9 9

Isolation kV RF peak (f=2MHz) 8 8

Capacitance pF coil/screen gnd 0.5 0.5

Lifetime operations dry switching 109 109

Contact Resistance mOhms maximum (typical) 50 (15) 50 (15)

Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)

ESR at 4.5A, 30MHz mOhms typical 30 30

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 11: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

11

radio frequency reed relays

MECHANICAL

Page 12: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

12

● Up to 20A Carry Current at 30MHz

● 6.5kV DCIsolation

● Fully ScreenedCoil for Low RFLoss

● Cost Effectivealternative to VacuumCeramicDevices

● Suitable for 1 kW HFTransmitters

FRD30000 Series Fully Screened. 6.5kV, 20AThis flagship relay series offered by Crydom employs multiple high vacuum reedswitch contacts ensuring excellent performance and reliability for high voltageand heavy carry current applications. The two basic models, FRD32061 andFRD32062 will carry currents of 12 and 20A respectively at 30MHz and featuresilver plated, fully screened coil assemblies for ultra-low RF losses. Typicalapplications include over the horizon (OTH) HF radar systems and 1kW basestation transmitters.

COIL at 20’C

Nominal Working Voltage VDC 24 24

Must Operate VDC max 16 16

Must Release VDC min 4 4

Nominal Resistance Ohms +/10% 430 270

RF Screening Full Full

RF Screening Connection pin number Via Mounting Screws Via Mounting Screws

RELAY

Operate time (incl. bounce) mS 5 5

Release time mS 3 3

Isolation contact to all

other terminals kV DC max 10 10

Isolation coil to screen kV DC max 0.5 0.5

Capacitance contact to

all other terminals pF contacts open 6.0 6.0

ENVIRONMENTAL

Storage temperature range °C -55 to +125

Operating temperature range °C -40 to +85

CONTACT UNITS CONDITIONS FRD32061 FRD32062

Action (form A, B or Latching) A A

Switching Voltage V DC max 20 20

Switching Current A DC max 1 1

Carry Current A RMS at 30MHz max 12 20

Isolation kV DC max 6 6.5

Capacitance (max.) pF coil/screen gnd 2 2

Lifetime operations dry switching 109 109

24V, 1A 107-108 107-108

Contact Resistance mOhms maximum (typical) 50 (10) 50 (10)

Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 13: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

13

radio frequency reed relays

MECHANICAL

( . "

Page 14: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

14

Operating temperature range ¡C -40 to +85

CONTACT UNITS CONDITIONS FRS12517 FRD32062

CONTACT US NOW

UNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

F

T

• Up to 3KV Isolation

• 3A Carry Current(up to 30MHz)

• Excellent RF

Characteristics

• Designed for HF

Applications

• Compact Package

on 0.1 " Pin Pitch

• Full Customising Facility

FRS12000 SeriesMiniature Single RF Reed Relay

Offering outstanding RF performance for their size, the FRS12000 series can

withstand RF voltages up to 3kV and carry RF currents of 3A at 30MHz. Utilising

plastic and encapsulant materials with exceptional RF and temperature

characteristics, the FRS12000 Series RF Reed Relays feature in house manufactured

reedswitches, with copper plating and high vacuum much revered in the industry for

their high power performance and reliability.

Designed on a standard 0. 1" pin pitch (some variants available on 0.15"), the

FRS12000 series can be fully customised to your requirements, with options for open

frame or encapsulated, magnetic screening, coil voltages, and contact configuration.

Crydom have also recently developed a 5kV version with contact pins exiting the cover

for flying lead connection. Contact Crydom for details.

Typical applications for the FRS12000 Series include antenna tuning units, as well as

harmonic and co-site filtering over the HF band.

CONTACT

COIL at 20°C

RELAY

ENVIRONMENTAL

UNITS CONDITIONS FRS12517 FRS12518

Action (form A, B or Latching) A A

Switching Voltage V DC max 20 20

Switching Current A DC max 0.5 0.5

Carry Current A RMS at 30MHz max 3 3

Isolation kV DC max 0.3 3

Capacitance pF coil/screen gnd 0.2 0.2

Contact Connections pin position 5 & 8 5 & 8

Nom. Working Voltage VDC 24 12

Working Voltage Range VDC 18-32 8-16.5

Must Operate VDC max 16 7

Must Release VDC min 2 1

Nominal Resistance ohms +/10% 1500 700

RF Screening Inner/Outer/Full I I & 0

RF Screening Connection pin position 11 11

Coil Connections pin position 3 &10 3 &10

Construction Single SingleOpen Frame With Cover

Operate time (incl. bounce) mS 0.6 1

Release time (incl. bounce) mS 0.4 0.5

Contact to all

other terminals kV DC max 0.1 1.5

Coil to screen kV DC max 0.1 0.5

Capacitance contact to

all other terms pF contacts open 1.5 2.0

Storage temperature range °C -55°C to +125°C

Operating temperature rang °C -40°C to +85°C9Lifetime ops dry switching 10

ops Rated load Consult factoryShock g 11ms 1/2 sine pk 100Bump g 6ms 1/2 sine pk 40Vibration g 60-500Hz 20

F

E

W

T

Page 15: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

15

radio frequency reed relays

MECHANICAL

SINGLE OPEN FRAME

10.00(0.39“)

SINGLEOPEN FRAME

20.32

(0.80“)

(0.38“)

9.80 Max

SINGLE WITH COVER SINGLEWITH COVER

1 2 3 4

96 8

10 11 127

1 2 3 4

9

5 8

10 11 12

7

1513 14

517

16

28.65 Max

(1.13“)

2.54

(0.10“)

30.60

(1.20“)

25.40

(1.00“)

8.00 Max

(0.31“)

2.54

(0.10“)

5.08

(0.20“)

PIN SIZE (DOUBLE-EXTENDED FOOT)PINS 3, 11 & 17 0.63 SQUARE (0.025“)PINS 5 & 8 0.7 (0.027“) dia.

PIN SIZE (SINGLE)PINS 3, 10 & 11 0.63 SQUARE (0.025“)PINS 5 & 8 0.7 (0.027“) dia.

11.50(0.15“)

11.50(0.45“)

6

Page 16: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

16

Up to 3KVIsolation

5A CarryCurrent (up to 30MHz)

Excellent RFCharacteristics

Designed for HF Applications

CompactPackage on 0.1" Pin Pitch

FullCustomisingFacility

FRS12000 SeriesScreened. 2kV, 5A

Crydom’s FRS12000 series feature two Crydom reed switches connected inparallel for higher current capability. Available in both open frame and coveredconstruction (depending upon voltage isolation requirements), the FRS12000series utilises materials with exceptional RF and temperature performancecharacteristics. In addition the coils are partially screened offering extendedRF performance over the HF band.

COIL at 20¡C

Nominal Working Voltage VDC 24 24

Must Operate VDC max 15 15

Must Release VDC min 4 4

Nominal Resistance ohms +/10% 1150 1000

RF Screening Part Part

RF Screening Connection pin position 17 15

Coil Connections pin position 3 & 11 4 & 13

RELAY

Construction Open Frame Covered

Operate time (incl. bounce) mS 2 2

Release time (incl. bounce) mS 1 1

Contact to all

other terminals kV DC max 0.5 2

Coil to screen kV DC max 0.5 0.5

Capacitance contact to

all other terminals pF contacts open 2.5 3.0

ENVIONMENTAL

Storage temperature range ¡C -55 to +125

Operating temperature range ¡C Limited current* -40 to +85

Shock g 11ms 1/2 sine pk 100

*see graphical data

CONTACT UNITS CONDITIONS FRS12030 FRS12208

Action (form A, B or Latching) A A

Switching Voltage V DC max 20 20

Switching Current A DC max 0.5 0.5

Carry Current A RMS 5 5

Isolation kV DC max 0.5 2

Capacitance pF coil/screen gnd 0.3 0.3

Contact Connections pin position 5 & 8 5 &12

9Lifetime operations dry switching 10 109

Contact Resistance mOhms maximum (typical) 80 (30) 80 (30)

Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)

ESR at 4.5A, 30MHz mOhms typical 90 90

CONTACT US NOW

UNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

F

T

F

E

W

T

Coil Connections pin position 3 & 11 4 & 13

RELAY

Page 17: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

17

radio frequency reed relays

Many other variants in the FRS12000 family are available with differentcoil and contact configurations, as well as a number of pin footprints fordrop-in replacements.

MECHANICAL

Page 18: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

18

BistableLatching Relay

0.5 ms CoilPulse length

3.5kV DCIsolation

1.5A CarryCurrent

RF & MagneticScreening

Approved to MILstandards forBump, Shockand Vibration

FRS22012 Fast Latching, Screened. 3.5kV, 1.5A

The FRS22012 latching RF reed relay designed for manpack portableHF radio systems where power resources are limited. The relay is capable ofwithstanding 3.5kV between contacts and carrying 1.5A current at 30MHz.The device features RF and magnetic screening, allowing close mounting, anda unique coil design enabling switching with coil pulse lengths down to 0.5ms,further reducing power supply demands. The FRS22012 is an ideal choice forapplications where board space is at a premium but where RF performanceis demanded.

COIL at 20¡C

Nom. Working Voltage VDC 12

Min. pulse length ms Minimum 0.5

Operate time ms diode fitted 0.5

Release time ms diode fitted 0.5

Nominal Resistance ohms +/10% 500

RF Screening Part

RF Screening Connection pin number 7

Coil Connections Set pin number 1 & 2(+)

Reset 5 & 6(+)

RELAY

Isolation contact to coil/screen kV DC max 4

Capacitance contact to all other terminals pF contacts open 2.5

Capacitance contact to all other terminals pF contacts closed 4.0

ENVIRONMENTAL

Operating temperature range ¡C -40 to +85

Storage temperature range ¡C -40 to +125

CONTACT UNITS CONDITIONS FRS22012

Action (form A, B or Latching) Latching

Switching Voltage V DC max 20

Switching Current A DC max 0.5

Carry Current A RMS at 30MHz 1.5

Isolation kV DC max 3.5

Capacitance pF coil/screen gnd 0.2

Contact Connections pin number 3 & 4

9Lifetime operations dry switching 10

Contact Resistance mOhms maximum (typical) 80 (30)

Insulation Resistance Ohms minimum (typical) 10 10 (1013)

ESR at 1.5A, 30MHz mOhms typical 400

CONTACT US NOW

UNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

F

T

F

E

W

T

Page 19: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

19

radio frequency reed relays

MECHANICAL

1

7

Page 20: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

● Low Cost● Form A, B

or LatchingContacts

● Excellent RFCharacteristics

● High IsolationVoltage

● ExcellentLifetimeCharacteristics

● Reed switchconnections via PCB‘through-hole’ or flying lead

4 SeriesScreened. 3.5kV, 3.5ADeveloped for RF applications (in the band 1-30MHz) the 4 series reed relay offersa highly fexible, low cost package available with form A (NO),form B (NC) andlatching (bistable) contact configurations as well as switch connections for eitherPCB or flying lead mounting. The use of Crydom’s vacuum reed switches withrhodium contacts means that high isolation voltages, low contact resistance andlong operating lifetimes are achieved. Additionally, RF screening is available tofurther enhance RF performance for more demanding applications.

COIL AT 20°C 5V 12V 24V 5V 12V 24V 5V 12V

Must Operate V DC 3.5 8 15 3.5 8 15 3 7

Must Release V DC 1 2 4 1 2 4 N/A N/A

Min Pulse Length ms N/A N/A N/A N/A N/A N/A 2.0 2.0

Operate Time ms 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

Release Time ms diode fitted 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0

Resistance Ohms 70 380 1500 65 350 1200 100 500

RELAY

Isolation contact to coil kV DC or AC peak 3 3 3.5

Capacitance contact to

all other terminals pF Contacts open <1.0 <1.0 <1.0

Capacitance contact

to all other terminals pF Contacts closed <1.5 <1.5 <1.5

ENVIRONMENTAL

Operating temperature range °C Limited Current* -40 to +100 -40 to +100 -40 to +100

Storage temperature range °C -40 to +125 -40 to +125 -40 to +125

*see graphical data

CONTACT UNITS CONDITIONS FORM A FORM B LATCHING

Contact Material Rhodium Rhodium Rhodium

Isolation across contacts kV DC or AC peak 3 3 3.5

Max. carry current A DC or AC rms* 3.5 3.5 1.5

Max. switching power W 10 10 10

Max. switching voltage V DC or AC peak 20 20 20

Max. switching current A DC or AC peak 0.5 0.5 0.5

Capacitance across contacts pF coil/screen grounded <0.1 <0.1 <0.1

Lifetime operations dry switching 109 109 109

Lifetime operations 10W switching 108 108 108

Contact Resistance mOhms maximum (typical) 80 (30) 80 (30) 80 (30)

Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013) 1010 (1013)

ESR at 30MHz (no screen) mOhms typical 95 @ 3A rms 95 @ 3A rms 200 @ 1.5A rms

ESR at 30MHz (part screen) mOhms typical 80 @ 3A rms 80 @ 3A rms 180 @ 1.5A rms

PART NUMBERING SYSTEM S A R 4 05 S U

Reedswitch Size - SContact Form A: Form A, B: Form B, L: LatchingContact Material R: RhodiumRelay Series NumberCoil Voltage 5: 5V, 12: 12V, 24: 24VScreening S: Screened, N: Unscreened Contact Pin Orientation D: PCB U: Flying Lead

20

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 21: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

21

MECHANICAL

°

radio frequency reed relays

Page 22: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

22

ENVIRONMENTAL

*see graphical data

PART NUMBERING SYSTEM S A R 5 05 S U

Reedswitch Size - S

Contact Form A: Form A, B: Form B, L: Latching

Contact Material R: RhodiumRelay Series NumberCoil Voltage 5: 5V, 12: 12V, 24: 24V

Screening S: Fully Screened Contact Pin Orientation D: PCB U: Flying Lead

6 SeriesMiniature, Fully Screened, Open Frame. 3.5kV, 4A

Developed closely with RF design Engineers in the radio communications industry,

this new fully screened reed relay series, offers low RF loss and high current

carrying capability. The robust shell construction enables the customer to specify

contact pin configuration. The relay coil section is totally enclosed in a copper

screen, resulting in lower self-heating and RF loss. Together with Crydom's vacuum

reed switches, benefits include higher carry currents for a given frequency and

ambient temperature. Peak RF isolation voltages up to 3.5kV are achieved by

clever coil design maximising pin spacing. Switch connections are offered for

either PCB or Flying Lead mounting

Contact Units Conditions Form A Form B Latching

Contact Material Rhodium Rhodium Rhodium

Isolation across contacts kV DC or AC peak 3 3 3.5

Max. carry current A DC or AC rms* 4 4 1.5

Max. switching power W 10 10 10

Max. switching voltage V DC or AC peak 20 20 20

Max. switching current A DC or AC peak 0.5 0.5 0.5

Capacitance across contacts pF coil/screen grounded <0.1 <0.1 <0.1

9 9 9Lifetime operations dry switching 10 10 10

8 8 8Lifetime operations 10W switching 10 10 10

Contact Resistance mOhms maximum (typical) 80 (30) 80 (30) 80 (30)

10 13 10 13 10 13Insulation Resistance Ohms minimum (typical) 10 (10 ) 10 (10 ) 10 (10 )

COIL 5V 12V 24V 5V 12V 24V 5V 12V

CONSTRUCTION

Must Operate V DC, 20°C 3.5 8 15 3.5 8 15 N/A N/A

Must Release V DC, 20°C 1 2 4 1 2 4 3 7

Min Pulse Length ms N/A N/A N/A N/A N/A N/A 2.0 2.0

Operate Time ms 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

Release Time ms diode fitted 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0

Resistance Ohms 20°C 70 380 1500 65 350 1200 100 500

Isolation contact to coil kV DC or AC peak 3 3 3.5

Operating temperature range °C Limited Current* -40 to +100 -40 to +100 -40 to +100

Storage temperature range °C -40 to +125 -40 to +125 -40 to +125

! Robust shell construction

! Versatile contactpin configuration

! Fully screenedminiature relay

! Excellent RFCharacteristics

! Carry current up to 4 amps (RMS) @30 MHz

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 23: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

23

MECHANICAL

radio frequency reed relays

SAR6xxSx / SBR6xxSx

Max Current vs. Frequency

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

0 5 10 15 20 25 30Frequency (MHz)

Cu

rre

nt

(A)

65°C

85°C

100°C

SLR6xxSx

Max Current vs Frequency

0

0.5

1

1.5

2

0 5 10 15 20 25 30

Frequency (MHz)

Cu

rre

nt

(A)

up to 100°C

Set Reset

Circuit diagram, Form A Circuit diagram, Form B

(all views from above)

--

++

--

(+)(+)

Circuit diagram, Latching

Pins require 1mm diameter holes

(0.59”)15.0 max.

(0.39”)

10.0 max.

25.4

29.5 max.

(0.59”)15.0 max.

29.5 max.

(1.16”)

(1.0”)

(1.16”)

5.08

(0.2”)

10.16(0.4”)

5.08

(0.2”)

Page 24: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

24

15kV Isolation

Low ContactResistance

High PowerSwitching

PCB or PanelMount

Flying Lead &Solder TurretOptions

Excellent ACCharacteristics

D Series15kV, 50W

Capable of withstanding voltages up to 15kV, the D-series High Voltage ReedRelay is suitable for high reliability applications such as cardiac defibrillators, test equipment and high voltage power supplies. Two contact materials areavailable for low contact resistance or power switching applications. Standard coil voltages of 5, 12 and 24 volts are available with form A and Bcontact configurations.

The D-series, range is now available with a new panel mounting option via nylonstuds, as well as a choice of electrical connection methods (solder turret tag andflying lead) complementing the standard PCB ‘through-hole’ device. Choose themost appropriate device for your application using the part numbering systembelow.

COIL AT 20¡C 5V 12V 24V 5V 12V 24V 5V 12V 24V

Must Operate V DC 3.7 9 20 3.7 9 20 3.7 9 20

Must Release V DC 0.5 1.25 4 0.5 1.25 4 0.5 1.25 4

Operate Time ms diode fitted 3.0 3.0 3.0 2.0 2.0 2.0 3.0 3.0 3.0

Release Time ms diode fitted 2.0 2.0 2.0 3.0 3.0 3.0 2.0 2.0 2.0

Resistance Ohms 28 150 780 38 240 925 16 95 350

RELAY

Isolation contact to coil kV DC or AC peak 17 17 17

Insulation resistance contactto all other terminals Ohms minimum (typical) 10 10 13(10 ) 10 10 (10 13) 10 10 (10 13)

ENVIRONMENTAL

Operating temperature range ¡ C - 20 to +70 -20 to +70 -20 to +70

CONTACT UNITS CONDITIONS 10KV FORM A 10KV FORM B 15KV FORM A

Contact material Rhodium Tungsten Rhodium Tungsten Tungsten

Isolation across contacts kV DC or AC peak 10 10 5 5 15

Max. switching power W 50 50 50 50 50

Max. switching voltage V DC or AC peak 1000 7000 1000 7000 10000

Max. switching current A DC or AC peak 3 2 3 2 2

Capacitance across

contacts pF coil/screen grounded <0.2 <0.2 <0.2 <0.2 <0.2

Lifetime operations dry switching 10 9 9 9 9 910 10 10 10

Lifetime operations 50W switching 10 6 6 6 6 810 10 10 10

Contact resistance mOhms maximum (typical) 50 (15) 250 (100) 50 (15) 250 (100) 250 (100)

Insulation Resistance Ohms minimum (typical) 10 10 (10 13) 10 10 (10 13) 10 10 (10 13) 10 10 (10 13) 1010 (10 13)

PART NUMBERING SYSTEM D A T 7 24 15 F

Reedswitch Size - D

Contact Form

A: Form A, B: Form B

Contact Material

R: Rhodium T: TungstenMoulding Ref. No.Coil Voltage

05: 5V, 12: 12V, 24: 24V

Mounting Style:

No suffix standard PCB mount

F: Flying lead contact terminals T: Turret contact terminals

P: Panel mount via nylon studs,turret contact/coil terminals

Isolation Between Contacts10: 10kV 15: 15kV (DAT only)

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 25: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

25

MECHANICAL

+

-

T

T71210P)

high voltage reed relays

0.63mm square pin

0.63mm square pin

0.63mm square pin

Page 26: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

26

● CompactFootprint

● DesignedSpecifically forHigh Voltage

● RhodiumContacts for Low Resistance

● 3 or 5kV Isolation betweenContacts

● ExcellentLifetimeCharacteristics

S Series5kV, 10WDeveloped for the high voltage ATE market, where PCB space is at a premium,the S Series High Voltage Reed Relay offers a 3 or 5kV isolation performancein a 30mm size package. With low contact resistance, the S Series HighVoltage Reed Relay will satisfy the many high voltage applications at DC andlow frequency, where performance and reliability are paramount.

COIL AT 20°C 5V 12V 24V 5V 12V 24V

Must Operate V DC 3.7 9 20 3.7 9 20

Must Release V DC 0.5 1.25 3 0.5 1.25 3

Operate Time ms diode fitted 1.0 1.0 1.0 1.0 1.0 1.0

Release Time ms diode fitted 0.5 0.5 0.5 0.5 0.5 0.5

Resistance Ohms 140 600 1000 140 600 1000

CONSTRUCTION

Isolation contact to coil kV DC or AC peak 5 5

to all other terminals Ohms minimum (typical) 1010 (1013) 1010 (1013)

ENVIRONMENTAL

Operating temperature range °C -20 to +70 -20 to +70

CONTACT UNITS CONDITIONS 3KV FORM A 5KV FORM A

Contact material Rhodium Rhodium

Isolation across contacts kV DC or AC peak 3 5

Max. carry current A DC or AC rms (60Hz) 2 2

Max. switching power W 10 10

Max. switching voltage V DC or AC peak 20 20

Max. switching current A DC or AC peak 0.5 0.5

Capacitance across contacts pF coil/screen grounded <0.1 <0.1

Lifetime operations dry switching 109 109

Lifetime operations 10W switching 108 108

Contact resistance mOhms maximum (typical) 80 (30) 80 (30)

Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)

PART NUMBERING SYSTEM S A R 9 12 05

Reedswitch Size - SContact Form A: Form AContact Material R: RhodiumMoulding Ref. No.Coil Voltage 05: 5V, 12: 12V, 24: 24VIsolation Between Contacts03: 3kV 05: 5kV

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 27: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

27

high voltage reed relays

MECHANICAL

Page 28: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

28

DIP SeriesReed Relay

Moulded Dual-in Line package reed relays designed for ATE, telecom, alarm and

other general purpose systems. Coils with optional diodes and/or screens and

mercury wetted contacts are available. Please contacts sales office for details.

CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED

FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE POWER

+/-10% MAXIMUM MINIMUM 20°C 60°C

COIL VDC Ohm voc VDC VDC VDC mw

01 01L/D/A 5 500 3.5 0.75 23.0 14.0 50

1A 02 02L/D 12 1000 8.4 1.8 33.0 20.0 144

05 15 2000 10.5 2.2 48.0 30.0 113

Flat package 24 2000 16.8 3.6 48.0 30.0 288

1A 01 02 01L H 5 1000 3.5 0.75 33.0 20.0 25

Flat package High ohms type 12 2000 8.4 1.8 48.0 30.0 72

01 03L 5 500 3.5 0.75 6.5 6.5 50

1B 02 03D 12 1000 8.4 1.8 15.6 15.6 144

05 15 2000 10.5 2.2 19.5 19.5 113

High package 24 2000 16.8 3.6 31.2 30.0 288

01 04L 5 200 3.5 0.75 14.0 9.0 125

2A 02 04D 12 500 8.4 1.8 23.0 14.0 288

05 15 2000 10.5 2.2 48.0 30.0 113

High package 24 2000 16.8 3.6 48.0 30.0 288

Flat package 05L 5 200 3.5 0.75 14.0 9.0 125

1C 20 12 500 8.4 1.8 23.0 14.0 288

15 2000 10.5 2.2 48.0 30.0 113

High package 05D 24 2000 16.8 3.6 48.0 30.0 288

Please note that the types with contact 05 form 1A and 1B have a reduced coil resistance of 2OOohms and 120ohms respectively.

(0.08“)2

5.10 max(0.20")

2.54

(0.10")

15.24

(0.60")

7.00 max(0.27")

7.50 max

(0.30")

0.50

(0.02")

15°

3.20(0.126")

19.30 max(0.76")

7.62

(0.30")

0.25 x 0.50(0.01") (0.02")

3.20

(0.126“) 15.24

(0.60")

15°

19.30 max(0.76")

7.62(0.30")

0.25 x 0.50(0.01") (0.02")

6.40 max

(0.25“)2.80

(0.11“)

2.54

(0.10")

5.70(0.22“)

Flat packageHigh package

MECHANICAL

D 12 - 1A 01 01 - L H

High Resistance Version

Options

L : without diode

D : Diode on pins 2 & 6

A : Diode on pins 6 & 9

Configuration

01, 02, 03, 04, 05

01, 02, 03, 04, 05

SeriesDual in line package (DIP)

Coil Voltage

5V, 12V, 24V

Contact Form1A, 1B, 2A, 1C

Contact Type

01, 02, 05, 20

PART NUMBERING SYSTEM - DIP SERIES

• Low Profile Package

• Standard and Non Standard Pin Configurations

available

• IC-pin compatible

• Interface Directlywith TTL-logic

• Up to 4.25 KVDCInsulation available

in 02L configuration

• Variants UL approved

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 29: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

29

high voltage reed relays

Contact Form A/dry A/dry A/d ry C/d ry

Rated Power max W 10 15 10 3

Switching Voltage max VDC 200 200 500 175

Switching Current max A 0,5 1,0 0,5 0,25

Carry Current A 1,0 1,25 1,0 1,2

Contact resistance max 0Q 150 150 200 150

Breakdown Voltage (contact/contact) min VDC 250 250 1'500 200

Operate time incl. bounce MS 0,5 0,5 0,5 0,7

Release time MS 0,1 0,1 0,1 1,0

CONTACT CONDITIONS UNITS 01 02 05 20

Shock at 11ms max G 35

Vibration at 50-500Hz max 920

OperatingTemperature oc 20+70

Storage Temperature oc 35 +95

Isolation coil/contact min kV 1,5 DC (4,25 DC /3,0 AC diagram 02L)

Insulation coil/contact min GQ 100

Life expectancy Dependent upon load, consult sales office

Solder time/temperature max 10 sec,/260'C

Washability Fully Sealed

Data at 140% of the nominal voltage and 20'C. Other switches against inquiry.

RELAY CONDITIONS UNITS

0201 03

04 05

14

1414

14

1

14

11

2

8

71

8

8

6

7

8

7

8

7

CONFIGURATION

Page 30: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

30

SIP SeriesReed Relays

PART NUMBERING SYSTEM-SIP SERIES

The SIP series reed relays are available in both voltage and current driven (line sense)

versions. The SIP range requires only half the PCB area of the DIP series.

The construction of the SIP series corresponds to the creepage and clearance

requirements of the new European Standards; EN60950.

CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED

FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE

POWER +/-10% MAXIMUM MINIMUM 20°C 60°C

COIL VDC Ohm VDC VDC VDC VDC mW

01 5 500 3.5 0.75 23 14 50

1A 02 12 1000 8.4 1.8 33 20 144

05 15 2000 10.5 2.2 47 29 112

24 2000 16.8 3.6 47 29 288

1A 02 01L M 5H 1000 3.5 0.75 33 20 25

02LM 12H 2000 8.4 1.8 47 29 72

Please note that the 5V types with contact 05 have a reduced coil resistance of 2OO.

CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED

FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE POWER

+/-10% MAXIMUM MINIMUM 20°C 60°C

Line Sense Ohm VDC VDC VDC VDC mH

Relay

1A 11 01M 15 15 5 240 149 3,45

Other coils on request

02 0301

CONFIGURATION

S 12 - 1A 02 01 - L H

High Resistance Version

Options

L : without diodeM : with magnetic screen

01D : Diode on pins 3 & 5,no magnetic screen

01Q : diode pins 3 & 5,with magnetic screen

02D : diode pins 2 & 6,no magnetic screen

02Q : diode pins 2 & 6,with magnetic screen

Configuration01, 02, 03

SeriesDual in line package (SIP)

Coil Voltage

5V, 12V, 24V

Contact Form1A

Contact Type

02, 05, 11

L/M/D/Q02

L/M/D/Q03L

• Designed to EN60950

• High Sensitivity Coils

up to 2,000 Ohms

@ 12V

• Line Sense Relay

Option available

• Magnetic and Diode

option available

• Insulation Voltage up

to 4.25kVdc

• Variants UL approved

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 31: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

31

high voltage reed relays

Contact Form A/dry A/d ry A/d ry

Rated Power max W 15 10 5

Switching Voltage max VDC 200 500 90

Switching Current max A 1,0 0,5 0,5

Carry Current A 1,25 1,0 1,0

Contact resistance max mohms 150 200 200

Breakdown Voltage (contact/contact) min VDC 250 1'500 100

Operate time incl. bounce ms 0,5 0,5 0,5

Release time ms 0,1 0,1 0,1

CONTACT CONDITIONS UNITS 02 05 11

Shock at 11ms max g 35

Vibration at 50-500Hz max g 20

OperatingTemperature °C -20/+70

Storage Temperature °C -35/+95

Isolation coil/contact min kV 1,5 DC (4,25 DC /3,0 AC at diagram 03L)

Insulation coil/contact min Gohms 100

Life expectancy Dependent upon load, consult sales office

Solder time/temperature max 10 sec,/260°C

Washability Fully Sealed

Data at 140% of the nominal voltage and 20°C. Other switches against inquiry.

RELAY CONDITIONS UNITS

5.00**** max

(0.196“)

3.5±0.20

(0.14") (0.008")

0.25

(0.10")

2.54

(0.10")

19.60* max

(0.78")

0.60 max

(0.023")

4.60 max

(0.18")

15.24

(0.60")

5.08 max

(0.20")

3.5±0.20

(0.14")(0.008")

0.25

(0.10")

Dimension with *(20.50 max)** (8.30 max) Magnetic screen(0.807") (0.33") (0.27") (0.24")

***(6.80 max) **** (6.00 max)

5.08

(0.20")

0.60 max

(0.023")

7.80** max

(0.31")

3.20 min

(0.126")

MECHANICAL

19.80* max

(0.78")

15.24

(0.60")

Page 32: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

32

Custom Relay Selector

Contact Specifications

Number of Poles 1 Other 2 3 4

Contact Form normally open

Isolating Voltage

Across contacts (kV) _____________________ DC/peak AC/RMS*

Contact to Contact (kV - for multiple contact relays) _______________________ DC/peak AC/RMS*

Contact to Coil/Screen (kV) _________________ DC/peak AC/RMS*

Switched Power

Switching Voltage (kV) ____________________

Switching Current (A) _____________________

Total Switching Power (W) _________________

Contact Carrying Current (A) ________________ If not resistive please describe ________________

closed latching

Signal Type DC/AC ........... Hz

RF parameters: (dB or m

Insertion loss/ESR ____________ isolation (dB) __________ return loss (dB) ________________

Contact resistance (m

)

Coil Drive Specifications

Nominal Coil Voltage (V) 5

) __________________________________

Operating Voltage Range (V - if nominal voltage varies) ____________________________________

Maximum Coil Drive Current (A) ____________________________

12 24

General

Electrostatic Shielding?

Physical dimensions (mm) L__________ W__________ H

Mounting method PCB

Magnetic Shielding?

Temperature Range (

Panel Mount Flying Leads

C) ___________________ Shock and Vibration approvals ___________¡

Any other requirements? _____________________________________________________________

Briefly describe the application: _______________________________________________________

_________________________________________________________________________________

Customer Name: ______________________________ Position: _________________________________

Company Address: ______________________________________________________________________

______________________________________________________________________________________

Tel. No. _________________________ Fax No. _______________________ Date: _________________

Quantity required: ___________ Purchase date: ____________ Purchasing contact: _________________

*Delete as applicable

Circuit Diagram/Contact Form/pin layout

Please return to your local representative or fax directly to +44 (0) 1202 891918

Please photocopy,complete andreturn this formand Crydom willreview your customrequirements.Alternatively, fill inthe on-line form atwww.crydom.co.uk

CONTACT US NOWUNITED KINGDOMCRYDOM

+44 (0)1202 897969+44 (0)1202 [email protected]

USACRYDOM

+1 858 715 7200+1 858 715 [email protected]

E

F

T

W

E

F

T

Page 33: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

our aim is to form closepartnerships withour customers,working with

levelsthem at all

Page 34: radio frequency, high voltage and custom reed relays...radio frequency reed relays (DC to 30MHz) Developed from Crydom’s expertise in high vacuum RF reed switches, the RF Reed Relay

Liquid Level Sensors

Liquid Flow Sensors

Fluid Control

Reed Switches

RF Reed Relays

High Voltage Reed Relays

General Purpose Reed Relays

DIP/SIP Reed Relays

Transformers

lnductors

Crydom Magnetics’ Product Portfolio

UNITED KINGDOMCRYDOM MAGNETICS LTD7 Cobham RoadFerndown Industrial EstateWimborneDorsetEngland BH21 7PEPhone: +44 (0) 1202 897969Fax: +44 (0) 1202 891918email: [email protected]:www.crydom.co.uk

USACRYDOM CORPORATION9525 Chesapeake DriveSan DiegoCA 92123USAPhone: +1 858 715 7200Fax: +1 858 715 7280e-mail: [email protected]: www.crydom.com

© 2000 CRYDOMEvery effort has been made to ensure that the information in this brochure isaccurate. Crydom is not responsible for printing/clerical errors or omissions.Specifications subject to change without prior notice.

Printed in UK - Design by Visual Assets. VA7670. 10.00 RR2000UK