Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
radio frequency, high voltage and custom
reed relays
radio frequency, high voltage and custom
reed relays
radio frequency, high voltage and custom
reed relays
our aim is
to form closepartnerships withour customers,working withthem at all levels
Crydom Magnetics Limited, an ISO9001
registered production facility based in
Wimborne, England, has been set up as
CrydomÕs centre of excellence for reed switches
and relays, liquid level, flow, proximity sensors
and transformers.
The company has been manufacturing reed switch and coil
based products for over thirty years. This site is equipped with
a state-of-the-art class 100 clean room facility, supplying high
quality reed switches into many of CrydomÕs reed-based
products. This ensures that Crydom controls production,
delivery and above all else, quality.
The companyÕs objective is to achieve profitable growth every
year by providing high quality products, backed by innovative
engineering and quality driven manufacturing processes.
With design, development and manufacturing under one roof,
our aim is to form close partnerships with our customers,
working with them at all levels from early feasibility studies to
delivering production quantities.
markets.
For further details visit the Crydom Magnetics
website at www.crydom.co.uk.
In order to achieve this, Crydom have established a team of
Agents and Distributors world-wide to service customer
requirements in local
radio frequency reed relays (DC to 30MHz)Developed from Crydom’s expertise in high vacuum RF reed switches, the RF
Reed Relay range offered today is a result of many years research and
development, working with the worldÕs top HF radio system manufacturers. With
relay solutions to suit all HF applications requiring voltage isolation up to 9kV and
carry currents up to 20Amps (RMS at 30MHz), Crydom has the engineering
expertise and experience to meet your exacting requirements.
Crydom Magnetics is unique in the industry as being a manufacturer of RF
vacuum reed switches and reed relays, not a relay manufacturer primarily
packaging other company’s reed switches. As a result, Crydom have full control
of the whole RF reed relay product ensuring the best in performance and quality.
A wide range of Crydom standard designs are offered with many coil screening
options to suit performance requirements and budgets. Two new miniature RF
reed relay designs are introduced for the first time. The 4 Series offers a low
cost and flexible package in all popular contact and coil configurations and
the 5 Series extends the RF performance with the first fully screened
miniature coil assembly offering ultra-low RF losses.
high voltage reed relaysCrydom’s 30 year experience in manufacturing high vacuum reedswitches
is prominent with the D and S-Series High Voltage Reed Relays. Capable
of withstanding up to 15kV DC, the D-Series High Voltage Reed Relay is
suitable for high reliability applications such as cardiac defibrillators, cable,
transformer and semiconductor test applications as well as high voltage
power supplies. New mounting and electrical connection options are now offered
alongside the popular PCB ‘through-hole’ relay.
If PCB space is at a premium, the miniature S Series High Voltage Reed Relay
is available in a 30mm size package. Capable of isolating up to 5kV DC, the
S Series was developed specifically for the
high voltage ATE market, where size,
performance and reliability are paramount.
custom reed relaysIf the products featured in this catalogue
do not quite meet your application requirements, please contact us. Having
supplied many hundreds of relay designs to the marketplace over the last
20 years, Crydom are geared towards providing custom RF, high voltage
and general purpose reed relays, drawing on standard, readily available
components, thus minimising development costs. A Custom Relay Selector is
provided on page 26 to help you specify your requirements. Please fill in and
return the form and we will be pleased to consider your specifications.
Alternatively fill in the on-line form at www.crydom.co.uk
radio frequency,high voltageand custom
reed relays
ISO 9001 registered
productionfacility, high
voltage & radiofrequency reedrelays for over
thirty years
selector guideradio frequency reed relays
Page
FRD12000 Series 8-9
Screened. 8kV, 6A
FRD13000 Series 10-11
Fully Screened. 9kV, 6A
FRD30000 Series 12-13
Fully Screened. 6.5kV, 20A
FRS12000 Series 14-15
Miniature Single RF
FRS22012 18-19
Fast Latching, Screened. 3.5V, 1.5A
4 Series 20-21
Screened. 3.5kV, 3.5A
6 Series 22-23
Fully Screened. 3.5kV, 4A
S Series 26-27
15kV, 50W
custom products
Application Notes 7
Custom Relay Selector 32
Dip Series 28-29
Sip Series 30-31
dip and sip reed relays
high voltage reed relays
D Series 24-25
15kV, 50W
FRS12000 Series 16-17
Screened. 2kV, 5A
General
Contact ArrangementRelays manufactured by Crydom have one of the following contactarrangements:
Form A : Normally open - energise to close contactsForm B : Normally closed - energise to open contactsLatching : Contact is bistable - energise ÒsetÓ coil to close
contacts; energise ÒresetÓ coil to open contacts
Coil SuppressionIt is recommended that all relay coils be suppressed by a diode. Thisis essential for latching relays. Operate and release times for therelays are quoted with coil suppression fitted.
Soldering & CleaningCrydomÕs reed relays are high performance products and thematerials and methods of construction are significant factorsin achieving performance specifications. The following guidelinesshould therefore be followed when adopting assembly, soldering andcleaning processes:
1) Soldering. Crydom propose that either low residue fluxes areused in the soldering process (to eliminate the need for cleaning),or that the reed relays are fitted onto the PCB after the cleaningprocess has taken place. If a solder bath is employed themaximum immersion time recommended is 10 seconds at 250¡Cor 3 seconds at 350¡C.
FRD12000/13000 Series: Electrical connection to the contacts ofthe FRD12000/13000 Series relay is via the reedswitch leadout.Care must be taken when hand soldering, as physical andthermal shocks can damage the glass to metal seals. A thermalshunt (aluminium clamp) carefully applied to the reedswitchleadout, adjacent to the glass seal will reduce the chances ofbreakage due to thermal shocks.
Alternatively, the relays should be warmed prior to soldering.
2) Cleaning. It is impossible for Crydom to offer blanket approval ofmethods, due to the many and varied automatic cleaning systemsnow available to conform to recent legislation.
If, after the soldering process, the customer wishes to clean PCBÕscontaining Crydom reed relays then the use of post operativecleaners such as IPA or HCFC based solvents with low pressurebrush applicators is recommended. Any customer wishing to usean alternative cleaning system should ensure that the fluids andprocesses are appropriate for application on Crydom reed relays.CrydomÕs devices are not hermetically sealed and as such,exposure to certain fluids can result in the degradation of therelay materials and subsequently a reduction in the electricalperformance. Please contact Crydom for further information onthe suitability of various cleaning solutions.
High Voltage Reed Relays
The principal function of a high voltage reed relay is to isolate as higha voltage as possible. In order to achieve this all Crydom high voltagereed relays employ evacuated reed switches. These switches areavailable with either Tungsten or Rhodium contacts depending uponthe switching characteristics required. As with all reed relays theyare susceptible to mutual magnetic interference when mountedin close proximity to each other. These parameters are discussed ingreater detail below.
Isolation VoltageThe isolation voltages specified correspond to DC or AC peak. Atmains frequencies (e.g. 50 or 60Hz) the two may be considereddirectly equivalent.
Contact Material - Rhodium vs TungstenRhodium contacts should be used where very low contact resistanceis required or when power switching at <1000V is undertaken.Tungsten contacts perform best when switching high voltages (1-10kV) at very low current. It should be noted that switchingpower will reduce relay operating life - the factory should becontacted for advice on specific applications.
Magnetic ScreeningCrydom high voltage reed relays are generally supplied withmagnetic screening fitted. However, this is not absolute and so, if theminimising of interference is critical, the mounting configuration infigure 1 below is recommended.
6
application notes
Figure 1 : Recommended Mounting for ‘S’ and ‘D’ Series High Voltage Reed Relays
RF Reed Relays
The basic requirements of RF reed relays are to provide minimal RFsignal loss and very low contact resistance over a long operatinglifetime. This is achieved in Crydom RF reed relays through the use ofcopper plated reed switches with Rhodium contacts in conjunctionwith carefully designed coil assemblies. They are intended for useacross the frequency range 1-30MHz and typical RF parameters foran RF reed relay across this band (measured in a 50 Ohm system) areshown in figure 2 below:
Particular to RF reed relays are the effects of RF and magneticscreening and these are discussed in more detail below. Also, highvoltage isolation considerations are specific to RF conditions.
RF ScreeningWhen an RF current is passed through the switch of a reed relay anelectromagnetic coupling between reed switch and coil results in someenergy being dissipated in the coil. This dissipation manifests itself asan addition to the effective series resistance (ESR) of the relay and, atcurrents of several amps, heating of the relay coil. RF coil heating isgreatest at high frequencies and varies in proportion to the square ofthe RF current carried in the switch. It is this factor which limitsmaximum carry current at high frequencies and ambient temperatures.The purpose of RF screening is to reduce these losses and extendrelay performance at high frequencies and high ambient temperatures.
Crydom RF reed relays are available with no screening, partialscreening and full RF screening of the coil, depending upon therequirements of the application.
Relays without an RF screen have restricted current carryingcapability at high ambient temperatures and frequencies (and ahigher associated ESR). However, this suits many typical ATUapplications well, as the highest currents occur only at the lowerfrequency bands (e.g. 2MHz).
Relays with partial RF screening have extended current carryingperformance at elevated ambient temperatures over unscreenedvariants.
Relays with full RF screening represent the ultimate in low loss RF reedrelay design. The ESR and resulting coil heating are significantly lowerthan for other types and this makes them suitable for applicationsin high ÒQÓ circuits where high currents are present over the wholefrequency range.
As an illustration of the effect of relay screening on ESR,measurements taken under load at 30MHz (i.e. the worst casefrequency) are shown in figure 3 below for fully, partially andunscreened ÒFRDÓ series reed relays.
Magnetic ScreeningWhen power is supplied to the coil of a reed relay a magnetic field isproduced. When relays are mounted in close proximity this can resultin mutual magnetic interference. However, Crydom RF reed relaysare generally not fitted with magnetic screens, as the presenceof ferromagnetic material around the coil can adversely affect ESRand RF coil heating as described above. For applications whererelays are mounted in close proximity the recommended mountingconfiguration is shown in figure 4 below.
Isolation VoltageAll withstand voltages are specified and tested at DC. However, highvoltage breakdown mechanisms at high frequency differ to those atDC. In general, breakdown across the reed contacts occurs at ahigher RF peak voltage than DC. Conversely, breakdown outside theswitch (e.g. switch to coil or screen), caused by surface tracking, canoccur more readily at high frequency than at DC. Verification of anyparticular voltage and frequency combination can be undertaken byCrydom upon request.
Figure 2 : Typical Parameters of Crydom RF Reed Relays
Figure 3: Effects of screening on ESR
Figure 4 : Mounting Configurations to Minimise Magnetic Interference ( *Note Orientation)
7
Up to 8kVDCIsolation
6A CarryCurrent (up to 30MHz)
Excellent RFPerformance
Ideal forAntenna TuningUnits
Form A/BContactConfiguration
CustomisingFacility
8
FRD12000 Series Screened. 8kV, 6A
The FRD12000 series was one of Crydom’s first RF reed relay designs. With 8kV(DC) withstand voltage and 6A (30MHz) carry current capability, the FRD12000series has satisfied countless HF radio system specifications over the years,finding applications in commercial maritime (GMDSS) equipment and military HFradio units worldwide.
COIL at 20¡C
Nominal Working Voltage VDC 24 12 12 24
Must Operate VDC max 15 8 8 14
Must Release VDC min 2 2 2 4
Nominal Resistance ohms +/10% 1000 380 340 1500
RF Screening Part - Part -
RF Screening Connection pin position 1 & 4 1 & 4
Coil Connections pin position 2 & 3 2 & 3 2 & 3 2 & 3
RELAY
Operate time (including bounce) ms 2 3 3 3
Release time ms 1 2 1 2
Isolation contact to all
other terminals kV DC max 10 10 10 10
Isolation coil to screen kV DC max 0.5 N/A 0.5 N/A
Capacitance contact to
all other terminals pF contacts open 2.0 2.5 2.0 2.5
ENVIRONMENTAL
Storage temperature range ¡C -55 to +125
Operating temperature range ¡C Limited current* -40 to +85
Shock g 11ms 1/2 sine pk 100
Bump g 6ms 1/2 sine pk 40
Vibration g 10- 500Hz 10
*see graphical data
CONTACT UNITS CONDITIONS FRD12015 FRD12021 FRD12014 FRD12049
Action (form A, B or Latching) A B A B
Switching Voltage V DC max 20 20 20 20
Switching Current A DC max 1 1 1 1
Carry Current A RMS max 6 6 6 6
Isolation kV DC max 8 8 8 8
Capacitance pF coil/screen gnd 0.4 0.6 0.4 0.6
9Lifetime operations dry switching 10 109 109 109
Contact Resistance mOhms maximum (typical) 50 (15) 50 (15) 50 (15) 50 (15)
Insulation Resistance Ohms minimum (typical) 1010(1013) 1010 (1013) 1010 (1013) 1010 (1013)
ESR at 4.5A, 30MHz mOhms typical 100 150 100 150
CONTACT US NOW
UNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
9
MECHANICAL
Available with either 12 or 24V coils, in both form A and B contactconfigurations, this proven design is fully approved to MIL standards ofbump, shock and vibration and features one of Crydom’s in-housemanufactured, high vacuum reed switches for unsurpassed RFperformance and reliability.
Offering a cost effective alternative to vacuum ceramic relays, theFRD12000 Series RF Reed Relay has a greater lifetime, imperative forfrequency hopping systems. As well as HF radios, the FRD12000 Serieshas also found applications in electromedical, sonar and test equipment,which require high isolation and inherent reliability.
radio frequency reed relays
10
● New FullyScreened Coilfor Low RF Loss
● Up to 9kVDCand 6A at30MHz
● Drop-inreplacement forFRD12000Series
● Ideal forAntenna TuningUnits
● CustomisingFacility
FRD13000 SeriesFully Screened. 9kV, 6AA development of the FRD12000 series, this design has a complete RF screenaround the coil assembly, offering a very low loss transmission path. This resultsin better carry current performance at elevated temperatures. This device alsofeatures an anti-corona sleeve shrouding the reed switch contact for improvedpeak RF voltage isolation.
COIL at 20°C
Nominal Working Voltage VDC 24 24
Must Operate VDC max 15 16
Must Release VDC min 3 3
Nominal Resistance Ohms +/10% 900 900
RF Screening Full Full
RF Screening Connection pin position 1 & 8 1 & 8
Coil Connections pin position 4 & 5 4 & 5(+)
RELAY
Operate time (incl. bounce) mS 2 1
Release time mS 1 2
Isolation contact to all other terminals kV DC max 9 9
Isolation coil to screen kV DC max 0.5 0.5
Capacitance contact to all other terminals pF contacts open 1.5 1.5
ENVIRONMENTAL
Storage temperature range °C -55 to +125
Operating temperature range °C Limited current* -40 to +85
Shock g 11ms 1/2 sine pk 100
Bump g 6ms 1/2 sine pk 40
Vibration g 10- 500Hz 10
*see graphical data
CONTACT UNITS CONDITIONS FRD13503 FRD13504
Action (form A, B or Latching) A B
Switching Voltage V DC max 20 20
Switching Current A DC max 1 1
Carry Current A RMS max 6 6
Isolation kV DC max 9 9
Isolation kV RF peak (f=2MHz) 8 8
Capacitance pF coil/screen gnd 0.5 0.5
Lifetime operations dry switching 109 109
Contact Resistance mOhms maximum (typical) 50 (15) 50 (15)
Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)
ESR at 4.5A, 30MHz mOhms typical 30 30
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
11
radio frequency reed relays
MECHANICAL
12
● Up to 20A Carry Current at 30MHz
● 6.5kV DCIsolation
● Fully ScreenedCoil for Low RFLoss
● Cost Effectivealternative to VacuumCeramicDevices
● Suitable for 1 kW HFTransmitters
FRD30000 Series Fully Screened. 6.5kV, 20AThis flagship relay series offered by Crydom employs multiple high vacuum reedswitch contacts ensuring excellent performance and reliability for high voltageand heavy carry current applications. The two basic models, FRD32061 andFRD32062 will carry currents of 12 and 20A respectively at 30MHz and featuresilver plated, fully screened coil assemblies for ultra-low RF losses. Typicalapplications include over the horizon (OTH) HF radar systems and 1kW basestation transmitters.
COIL at 20’C
Nominal Working Voltage VDC 24 24
Must Operate VDC max 16 16
Must Release VDC min 4 4
Nominal Resistance Ohms +/10% 430 270
RF Screening Full Full
RF Screening Connection pin number Via Mounting Screws Via Mounting Screws
RELAY
Operate time (incl. bounce) mS 5 5
Release time mS 3 3
Isolation contact to all
other terminals kV DC max 10 10
Isolation coil to screen kV DC max 0.5 0.5
Capacitance contact to
all other terminals pF contacts open 6.0 6.0
ENVIRONMENTAL
Storage temperature range °C -55 to +125
Operating temperature range °C -40 to +85
CONTACT UNITS CONDITIONS FRD32061 FRD32062
Action (form A, B or Latching) A A
Switching Voltage V DC max 20 20
Switching Current A DC max 1 1
Carry Current A RMS at 30MHz max 12 20
Isolation kV DC max 6 6.5
Capacitance (max.) pF coil/screen gnd 2 2
Lifetime operations dry switching 109 109
24V, 1A 107-108 107-108
Contact Resistance mOhms maximum (typical) 50 (10) 50 (10)
Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
13
radio frequency reed relays
MECHANICAL
( . "
14
Operating temperature range ¡C -40 to +85
CONTACT UNITS CONDITIONS FRS12517 FRD32062
CONTACT US NOW
UNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
F
T
• Up to 3KV Isolation
• 3A Carry Current(up to 30MHz)
• Excellent RF
Characteristics
• Designed for HF
Applications
• Compact Package
on 0.1 " Pin Pitch
• Full Customising Facility
FRS12000 SeriesMiniature Single RF Reed Relay
Offering outstanding RF performance for their size, the FRS12000 series can
withstand RF voltages up to 3kV and carry RF currents of 3A at 30MHz. Utilising
plastic and encapsulant materials with exceptional RF and temperature
characteristics, the FRS12000 Series RF Reed Relays feature in house manufactured
reedswitches, with copper plating and high vacuum much revered in the industry for
their high power performance and reliability.
Designed on a standard 0. 1" pin pitch (some variants available on 0.15"), the
FRS12000 series can be fully customised to your requirements, with options for open
frame or encapsulated, magnetic screening, coil voltages, and contact configuration.
Crydom have also recently developed a 5kV version with contact pins exiting the cover
for flying lead connection. Contact Crydom for details.
Typical applications for the FRS12000 Series include antenna tuning units, as well as
harmonic and co-site filtering over the HF band.
CONTACT
COIL at 20°C
RELAY
ENVIRONMENTAL
UNITS CONDITIONS FRS12517 FRS12518
Action (form A, B or Latching) A A
Switching Voltage V DC max 20 20
Switching Current A DC max 0.5 0.5
Carry Current A RMS at 30MHz max 3 3
Isolation kV DC max 0.3 3
Capacitance pF coil/screen gnd 0.2 0.2
Contact Connections pin position 5 & 8 5 & 8
Nom. Working Voltage VDC 24 12
Working Voltage Range VDC 18-32 8-16.5
Must Operate VDC max 16 7
Must Release VDC min 2 1
Nominal Resistance ohms +/10% 1500 700
RF Screening Inner/Outer/Full I I & 0
RF Screening Connection pin position 11 11
Coil Connections pin position 3 &10 3 &10
Construction Single SingleOpen Frame With Cover
Operate time (incl. bounce) mS 0.6 1
Release time (incl. bounce) mS 0.4 0.5
Contact to all
other terminals kV DC max 0.1 1.5
Coil to screen kV DC max 0.1 0.5
Capacitance contact to
all other terms pF contacts open 1.5 2.0
Storage temperature range °C -55°C to +125°C
Operating temperature rang °C -40°C to +85°C9Lifetime ops dry switching 10
ops Rated load Consult factoryShock g 11ms 1/2 sine pk 100Bump g 6ms 1/2 sine pk 40Vibration g 60-500Hz 20
F
E
W
T
15
radio frequency reed relays
MECHANICAL
SINGLE OPEN FRAME
10.00(0.39“)
SINGLEOPEN FRAME
20.32
(0.80“)
(0.38“)
9.80 Max
SINGLE WITH COVER SINGLEWITH COVER
1 2 3 4
96 8
10 11 127
1 2 3 4
9
5 8
10 11 12
7
1513 14
517
16
28.65 Max
(1.13“)
2.54
(0.10“)
30.60
(1.20“)
25.40
(1.00“)
8.00 Max
(0.31“)
2.54
(0.10“)
5.08
(0.20“)
PIN SIZE (DOUBLE-EXTENDED FOOT)PINS 3, 11 & 17 0.63 SQUARE (0.025“)PINS 5 & 8 0.7 (0.027“) dia.
PIN SIZE (SINGLE)PINS 3, 10 & 11 0.63 SQUARE (0.025“)PINS 5 & 8 0.7 (0.027“) dia.
11.50(0.15“)
11.50(0.45“)
6
16
Up to 3KVIsolation
5A CarryCurrent (up to 30MHz)
Excellent RFCharacteristics
Designed for HF Applications
CompactPackage on 0.1" Pin Pitch
FullCustomisingFacility
FRS12000 SeriesScreened. 2kV, 5A
Crydom’s FRS12000 series feature two Crydom reed switches connected inparallel for higher current capability. Available in both open frame and coveredconstruction (depending upon voltage isolation requirements), the FRS12000series utilises materials with exceptional RF and temperature performancecharacteristics. In addition the coils are partially screened offering extendedRF performance over the HF band.
COIL at 20¡C
Nominal Working Voltage VDC 24 24
Must Operate VDC max 15 15
Must Release VDC min 4 4
Nominal Resistance ohms +/10% 1150 1000
RF Screening Part Part
RF Screening Connection pin position 17 15
Coil Connections pin position 3 & 11 4 & 13
RELAY
Construction Open Frame Covered
Operate time (incl. bounce) mS 2 2
Release time (incl. bounce) mS 1 1
Contact to all
other terminals kV DC max 0.5 2
Coil to screen kV DC max 0.5 0.5
Capacitance contact to
all other terminals pF contacts open 2.5 3.0
ENVIONMENTAL
Storage temperature range ¡C -55 to +125
Operating temperature range ¡C Limited current* -40 to +85
Shock g 11ms 1/2 sine pk 100
*see graphical data
CONTACT UNITS CONDITIONS FRS12030 FRS12208
Action (form A, B or Latching) A A
Switching Voltage V DC max 20 20
Switching Current A DC max 0.5 0.5
Carry Current A RMS 5 5
Isolation kV DC max 0.5 2
Capacitance pF coil/screen gnd 0.3 0.3
Contact Connections pin position 5 & 8 5 &12
9Lifetime operations dry switching 10 109
Contact Resistance mOhms maximum (typical) 80 (30) 80 (30)
Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)
ESR at 4.5A, 30MHz mOhms typical 90 90
CONTACT US NOW
UNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
F
T
F
E
W
T
Coil Connections pin position 3 & 11 4 & 13
RELAY
17
radio frequency reed relays
Many other variants in the FRS12000 family are available with differentcoil and contact configurations, as well as a number of pin footprints fordrop-in replacements.
MECHANICAL
18
BistableLatching Relay
0.5 ms CoilPulse length
3.5kV DCIsolation
1.5A CarryCurrent
RF & MagneticScreening
Approved to MILstandards forBump, Shockand Vibration
FRS22012 Fast Latching, Screened. 3.5kV, 1.5A
The FRS22012 latching RF reed relay designed for manpack portableHF radio systems where power resources are limited. The relay is capable ofwithstanding 3.5kV between contacts and carrying 1.5A current at 30MHz.The device features RF and magnetic screening, allowing close mounting, anda unique coil design enabling switching with coil pulse lengths down to 0.5ms,further reducing power supply demands. The FRS22012 is an ideal choice forapplications where board space is at a premium but where RF performanceis demanded.
COIL at 20¡C
Nom. Working Voltage VDC 12
Min. pulse length ms Minimum 0.5
Operate time ms diode fitted 0.5
Release time ms diode fitted 0.5
Nominal Resistance ohms +/10% 500
RF Screening Part
RF Screening Connection pin number 7
Coil Connections Set pin number 1 & 2(+)
Reset 5 & 6(+)
RELAY
Isolation contact to coil/screen kV DC max 4
Capacitance contact to all other terminals pF contacts open 2.5
Capacitance contact to all other terminals pF contacts closed 4.0
ENVIRONMENTAL
Operating temperature range ¡C -40 to +85
Storage temperature range ¡C -40 to +125
CONTACT UNITS CONDITIONS FRS22012
Action (form A, B or Latching) Latching
Switching Voltage V DC max 20
Switching Current A DC max 0.5
Carry Current A RMS at 30MHz 1.5
Isolation kV DC max 3.5
Capacitance pF coil/screen gnd 0.2
Contact Connections pin number 3 & 4
9Lifetime operations dry switching 10
Contact Resistance mOhms maximum (typical) 80 (30)
Insulation Resistance Ohms minimum (typical) 10 10 (1013)
ESR at 1.5A, 30MHz mOhms typical 400
CONTACT US NOW
UNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
F
T
F
E
W
T
19
radio frequency reed relays
MECHANICAL
1
7
● Low Cost● Form A, B
or LatchingContacts
● Excellent RFCharacteristics
● High IsolationVoltage
● ExcellentLifetimeCharacteristics
● Reed switchconnections via PCB‘through-hole’ or flying lead
4 SeriesScreened. 3.5kV, 3.5ADeveloped for RF applications (in the band 1-30MHz) the 4 series reed relay offersa highly fexible, low cost package available with form A (NO),form B (NC) andlatching (bistable) contact configurations as well as switch connections for eitherPCB or flying lead mounting. The use of Crydom’s vacuum reed switches withrhodium contacts means that high isolation voltages, low contact resistance andlong operating lifetimes are achieved. Additionally, RF screening is available tofurther enhance RF performance for more demanding applications.
COIL AT 20°C 5V 12V 24V 5V 12V 24V 5V 12V
Must Operate V DC 3.5 8 15 3.5 8 15 3 7
Must Release V DC 1 2 4 1 2 4 N/A N/A
Min Pulse Length ms N/A N/A N/A N/A N/A N/A 2.0 2.0
Operate Time ms 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Release Time ms diode fitted 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0
Resistance Ohms 70 380 1500 65 350 1200 100 500
RELAY
Isolation contact to coil kV DC or AC peak 3 3 3.5
Capacitance contact to
all other terminals pF Contacts open <1.0 <1.0 <1.0
Capacitance contact
to all other terminals pF Contacts closed <1.5 <1.5 <1.5
ENVIRONMENTAL
Operating temperature range °C Limited Current* -40 to +100 -40 to +100 -40 to +100
Storage temperature range °C -40 to +125 -40 to +125 -40 to +125
*see graphical data
CONTACT UNITS CONDITIONS FORM A FORM B LATCHING
Contact Material Rhodium Rhodium Rhodium
Isolation across contacts kV DC or AC peak 3 3 3.5
Max. carry current A DC or AC rms* 3.5 3.5 1.5
Max. switching power W 10 10 10
Max. switching voltage V DC or AC peak 20 20 20
Max. switching current A DC or AC peak 0.5 0.5 0.5
Capacitance across contacts pF coil/screen grounded <0.1 <0.1 <0.1
Lifetime operations dry switching 109 109 109
Lifetime operations 10W switching 108 108 108
Contact Resistance mOhms maximum (typical) 80 (30) 80 (30) 80 (30)
Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013) 1010 (1013)
ESR at 30MHz (no screen) mOhms typical 95 @ 3A rms 95 @ 3A rms 200 @ 1.5A rms
ESR at 30MHz (part screen) mOhms typical 80 @ 3A rms 80 @ 3A rms 180 @ 1.5A rms
PART NUMBERING SYSTEM S A R 4 05 S U
Reedswitch Size - SContact Form A: Form A, B: Form B, L: LatchingContact Material R: RhodiumRelay Series NumberCoil Voltage 5: 5V, 12: 12V, 24: 24VScreening S: Screened, N: Unscreened Contact Pin Orientation D: PCB U: Flying Lead
20
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
21
MECHANICAL
°
radio frequency reed relays
22
ENVIRONMENTAL
*see graphical data
PART NUMBERING SYSTEM S A R 5 05 S U
Reedswitch Size - S
Contact Form A: Form A, B: Form B, L: Latching
Contact Material R: RhodiumRelay Series NumberCoil Voltage 5: 5V, 12: 12V, 24: 24V
Screening S: Fully Screened Contact Pin Orientation D: PCB U: Flying Lead
6 SeriesMiniature, Fully Screened, Open Frame. 3.5kV, 4A
Developed closely with RF design Engineers in the radio communications industry,
this new fully screened reed relay series, offers low RF loss and high current
carrying capability. The robust shell construction enables the customer to specify
contact pin configuration. The relay coil section is totally enclosed in a copper
screen, resulting in lower self-heating and RF loss. Together with Crydom's vacuum
reed switches, benefits include higher carry currents for a given frequency and
ambient temperature. Peak RF isolation voltages up to 3.5kV are achieved by
clever coil design maximising pin spacing. Switch connections are offered for
either PCB or Flying Lead mounting
Contact Units Conditions Form A Form B Latching
Contact Material Rhodium Rhodium Rhodium
Isolation across contacts kV DC or AC peak 3 3 3.5
Max. carry current A DC or AC rms* 4 4 1.5
Max. switching power W 10 10 10
Max. switching voltage V DC or AC peak 20 20 20
Max. switching current A DC or AC peak 0.5 0.5 0.5
Capacitance across contacts pF coil/screen grounded <0.1 <0.1 <0.1
9 9 9Lifetime operations dry switching 10 10 10
8 8 8Lifetime operations 10W switching 10 10 10
Contact Resistance mOhms maximum (typical) 80 (30) 80 (30) 80 (30)
10 13 10 13 10 13Insulation Resistance Ohms minimum (typical) 10 (10 ) 10 (10 ) 10 (10 )
COIL 5V 12V 24V 5V 12V 24V 5V 12V
CONSTRUCTION
Must Operate V DC, 20°C 3.5 8 15 3.5 8 15 N/A N/A
Must Release V DC, 20°C 1 2 4 1 2 4 3 7
Min Pulse Length ms N/A N/A N/A N/A N/A N/A 2.0 2.0
Operate Time ms 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Release Time ms diode fitted 0.5 0.5 0.5 0.5 0.5 0.5 1.0 1.0
Resistance Ohms 20°C 70 380 1500 65 350 1200 100 500
Isolation contact to coil kV DC or AC peak 3 3 3.5
Operating temperature range °C Limited Current* -40 to +100 -40 to +100 -40 to +100
Storage temperature range °C -40 to +125 -40 to +125 -40 to +125
! Robust shell construction
! Versatile contactpin configuration
! Fully screenedminiature relay
! Excellent RFCharacteristics
! Carry current up to 4 amps (RMS) @30 MHz
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
23
MECHANICAL
radio frequency reed relays
SAR6xxSx / SBR6xxSx
Max Current vs. Frequency
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 5 10 15 20 25 30Frequency (MHz)
Cu
rre
nt
(A)
65°C
85°C
100°C
SLR6xxSx
Max Current vs Frequency
0
0.5
1
1.5
2
0 5 10 15 20 25 30
Frequency (MHz)
Cu
rre
nt
(A)
up to 100°C
Set Reset
Circuit diagram, Form A Circuit diagram, Form B
(all views from above)
--
++
--
(+)(+)
Circuit diagram, Latching
Pins require 1mm diameter holes
(0.59”)15.0 max.
(0.39”)
10.0 max.
25.4
29.5 max.
(0.59”)15.0 max.
29.5 max.
(1.16”)
(1.0”)
(1.16”)
5.08
(0.2”)
10.16(0.4”)
5.08
(0.2”)
24
15kV Isolation
Low ContactResistance
High PowerSwitching
PCB or PanelMount
Flying Lead &Solder TurretOptions
Excellent ACCharacteristics
D Series15kV, 50W
Capable of withstanding voltages up to 15kV, the D-series High Voltage ReedRelay is suitable for high reliability applications such as cardiac defibrillators, test equipment and high voltage power supplies. Two contact materials areavailable for low contact resistance or power switching applications. Standard coil voltages of 5, 12 and 24 volts are available with form A and Bcontact configurations.
The D-series, range is now available with a new panel mounting option via nylonstuds, as well as a choice of electrical connection methods (solder turret tag andflying lead) complementing the standard PCB ‘through-hole’ device. Choose themost appropriate device for your application using the part numbering systembelow.
COIL AT 20¡C 5V 12V 24V 5V 12V 24V 5V 12V 24V
Must Operate V DC 3.7 9 20 3.7 9 20 3.7 9 20
Must Release V DC 0.5 1.25 4 0.5 1.25 4 0.5 1.25 4
Operate Time ms diode fitted 3.0 3.0 3.0 2.0 2.0 2.0 3.0 3.0 3.0
Release Time ms diode fitted 2.0 2.0 2.0 3.0 3.0 3.0 2.0 2.0 2.0
Resistance Ohms 28 150 780 38 240 925 16 95 350
RELAY
Isolation contact to coil kV DC or AC peak 17 17 17
Insulation resistance contactto all other terminals Ohms minimum (typical) 10 10 13(10 ) 10 10 (10 13) 10 10 (10 13)
ENVIRONMENTAL
Operating temperature range ¡ C - 20 to +70 -20 to +70 -20 to +70
CONTACT UNITS CONDITIONS 10KV FORM A 10KV FORM B 15KV FORM A
Contact material Rhodium Tungsten Rhodium Tungsten Tungsten
Isolation across contacts kV DC or AC peak 10 10 5 5 15
Max. switching power W 50 50 50 50 50
Max. switching voltage V DC or AC peak 1000 7000 1000 7000 10000
Max. switching current A DC or AC peak 3 2 3 2 2
Capacitance across
contacts pF coil/screen grounded <0.2 <0.2 <0.2 <0.2 <0.2
Lifetime operations dry switching 10 9 9 9 9 910 10 10 10
Lifetime operations 50W switching 10 6 6 6 6 810 10 10 10
Contact resistance mOhms maximum (typical) 50 (15) 250 (100) 50 (15) 250 (100) 250 (100)
Insulation Resistance Ohms minimum (typical) 10 10 (10 13) 10 10 (10 13) 10 10 (10 13) 10 10 (10 13) 1010 (10 13)
PART NUMBERING SYSTEM D A T 7 24 15 F
Reedswitch Size - D
Contact Form
A: Form A, B: Form B
Contact Material
R: Rhodium T: TungstenMoulding Ref. No.Coil Voltage
05: 5V, 12: 12V, 24: 24V
Mounting Style:
No suffix standard PCB mount
F: Flying lead contact terminals T: Turret contact terminals
P: Panel mount via nylon studs,turret contact/coil terminals
Isolation Between Contacts10: 10kV 15: 15kV (DAT only)
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
25
MECHANICAL
+
-
T
T71210P)
high voltage reed relays
0.63mm square pin
0.63mm square pin
0.63mm square pin
26
● CompactFootprint
● DesignedSpecifically forHigh Voltage
● RhodiumContacts for Low Resistance
● 3 or 5kV Isolation betweenContacts
● ExcellentLifetimeCharacteristics
S Series5kV, 10WDeveloped for the high voltage ATE market, where PCB space is at a premium,the S Series High Voltage Reed Relay offers a 3 or 5kV isolation performancein a 30mm size package. With low contact resistance, the S Series HighVoltage Reed Relay will satisfy the many high voltage applications at DC andlow frequency, where performance and reliability are paramount.
COIL AT 20°C 5V 12V 24V 5V 12V 24V
Must Operate V DC 3.7 9 20 3.7 9 20
Must Release V DC 0.5 1.25 3 0.5 1.25 3
Operate Time ms diode fitted 1.0 1.0 1.0 1.0 1.0 1.0
Release Time ms diode fitted 0.5 0.5 0.5 0.5 0.5 0.5
Resistance Ohms 140 600 1000 140 600 1000
CONSTRUCTION
Isolation contact to coil kV DC or AC peak 5 5
to all other terminals Ohms minimum (typical) 1010 (1013) 1010 (1013)
ENVIRONMENTAL
Operating temperature range °C -20 to +70 -20 to +70
CONTACT UNITS CONDITIONS 3KV FORM A 5KV FORM A
Contact material Rhodium Rhodium
Isolation across contacts kV DC or AC peak 3 5
Max. carry current A DC or AC rms (60Hz) 2 2
Max. switching power W 10 10
Max. switching voltage V DC or AC peak 20 20
Max. switching current A DC or AC peak 0.5 0.5
Capacitance across contacts pF coil/screen grounded <0.1 <0.1
Lifetime operations dry switching 109 109
Lifetime operations 10W switching 108 108
Contact resistance mOhms maximum (typical) 80 (30) 80 (30)
Insulation Resistance Ohms minimum (typical) 1010 (1013) 1010 (1013)
PART NUMBERING SYSTEM S A R 9 12 05
Reedswitch Size - SContact Form A: Form AContact Material R: RhodiumMoulding Ref. No.Coil Voltage 05: 5V, 12: 12V, 24: 24VIsolation Between Contacts03: 3kV 05: 5kV
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
27
high voltage reed relays
MECHANICAL
28
DIP SeriesReed Relay
Moulded Dual-in Line package reed relays designed for ATE, telecom, alarm and
other general purpose systems. Coils with optional diodes and/or screens and
mercury wetted contacts are available. Please contacts sales office for details.
CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED
FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE POWER
+/-10% MAXIMUM MINIMUM 20°C 60°C
COIL VDC Ohm voc VDC VDC VDC mw
01 01L/D/A 5 500 3.5 0.75 23.0 14.0 50
1A 02 02L/D 12 1000 8.4 1.8 33.0 20.0 144
05 15 2000 10.5 2.2 48.0 30.0 113
Flat package 24 2000 16.8 3.6 48.0 30.0 288
1A 01 02 01L H 5 1000 3.5 0.75 33.0 20.0 25
Flat package High ohms type 12 2000 8.4 1.8 48.0 30.0 72
01 03L 5 500 3.5 0.75 6.5 6.5 50
1B 02 03D 12 1000 8.4 1.8 15.6 15.6 144
05 15 2000 10.5 2.2 19.5 19.5 113
High package 24 2000 16.8 3.6 31.2 30.0 288
01 04L 5 200 3.5 0.75 14.0 9.0 125
2A 02 04D 12 500 8.4 1.8 23.0 14.0 288
05 15 2000 10.5 2.2 48.0 30.0 113
High package 24 2000 16.8 3.6 48.0 30.0 288
Flat package 05L 5 200 3.5 0.75 14.0 9.0 125
1C 20 12 500 8.4 1.8 23.0 14.0 288
15 2000 10.5 2.2 48.0 30.0 113
High package 05D 24 2000 16.8 3.6 48.0 30.0 288
Please note that the types with contact 05 form 1A and 1B have a reduced coil resistance of 2OOohms and 120ohms respectively.
(0.08“)2
5.10 max(0.20")
2.54
(0.10")
15.24
(0.60")
7.00 max(0.27")
7.50 max
(0.30")
0.50
(0.02")
15°
3.20(0.126")
19.30 max(0.76")
7.62
(0.30")
0.25 x 0.50(0.01") (0.02")
3.20
(0.126“) 15.24
(0.60")
15°
19.30 max(0.76")
7.62(0.30")
0.25 x 0.50(0.01") (0.02")
6.40 max
(0.25“)2.80
(0.11“)
2.54
(0.10")
5.70(0.22“)
Flat packageHigh package
MECHANICAL
D 12 - 1A 01 01 - L H
High Resistance Version
Options
L : without diode
D : Diode on pins 2 & 6
A : Diode on pins 6 & 9
Configuration
01, 02, 03, 04, 05
01, 02, 03, 04, 05
SeriesDual in line package (DIP)
Coil Voltage
5V, 12V, 24V
Contact Form1A, 1B, 2A, 1C
Contact Type
01, 02, 05, 20
PART NUMBERING SYSTEM - DIP SERIES
• Low Profile Package
• Standard and Non Standard Pin Configurations
available
• IC-pin compatible
• Interface Directlywith TTL-logic
• Up to 4.25 KVDCInsulation available
in 02L configuration
• Variants UL approved
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
29
high voltage reed relays
Contact Form A/dry A/dry A/d ry C/d ry
Rated Power max W 10 15 10 3
Switching Voltage max VDC 200 200 500 175
Switching Current max A 0,5 1,0 0,5 0,25
Carry Current A 1,0 1,25 1,0 1,2
Contact resistance max 0Q 150 150 200 150
Breakdown Voltage (contact/contact) min VDC 250 250 1'500 200
Operate time incl. bounce MS 0,5 0,5 0,5 0,7
Release time MS 0,1 0,1 0,1 1,0
CONTACT CONDITIONS UNITS 01 02 05 20
Shock at 11ms max G 35
Vibration at 50-500Hz max 920
OperatingTemperature oc 20+70
Storage Temperature oc 35 +95
Isolation coil/contact min kV 1,5 DC (4,25 DC /3,0 AC diagram 02L)
Insulation coil/contact min GQ 100
Life expectancy Dependent upon load, consult sales office
Solder time/temperature max 10 sec,/260'C
Washability Fully Sealed
Data at 140% of the nominal voltage and 20'C. Other switches against inquiry.
RELAY CONDITIONS UNITS
0201 03
04 05
14
1414
14
1
14
11
2
8
71
8
8
6
7
8
7
8
7
CONFIGURATION
30
SIP SeriesReed Relays
PART NUMBERING SYSTEM-SIP SERIES
The SIP series reed relays are available in both voltage and current driven (line sense)
versions. The SIP range requires only half the PCB area of the DIP series.
The construction of the SIP series corresponds to the creepage and clearance
requirements of the new European Standards; EN60950.
CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED
FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE
POWER +/-10% MAXIMUM MINIMUM 20°C 60°C
COIL VDC Ohm VDC VDC VDC VDC mW
01 5 500 3.5 0.75 23 14 50
1A 02 12 1000 8.4 1.8 33 20 144
05 15 2000 10.5 2.2 47 29 112
24 2000 16.8 3.6 47 29 288
1A 02 01L M 5H 1000 3.5 0.75 33 20 25
02LM 12H 2000 8.4 1.8 47 29 72
Please note that the 5V types with contact 05 have a reduced coil resistance of 2OO.
CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED
FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE POWER
+/-10% MAXIMUM MINIMUM 20°C 60°C
Line Sense Ohm VDC VDC VDC VDC mH
Relay
1A 11 01M 15 15 5 240 149 3,45
Other coils on request
02 0301
CONFIGURATION
S 12 - 1A 02 01 - L H
High Resistance Version
Options
L : without diodeM : with magnetic screen
01D : Diode on pins 3 & 5,no magnetic screen
01Q : diode pins 3 & 5,with magnetic screen
02D : diode pins 2 & 6,no magnetic screen
02Q : diode pins 2 & 6,with magnetic screen
Configuration01, 02, 03
SeriesDual in line package (SIP)
Coil Voltage
5V, 12V, 24V
Contact Form1A
Contact Type
02, 05, 11
L/M/D/Q02
L/M/D/Q03L
• Designed to EN60950
• High Sensitivity Coils
up to 2,000 Ohms
@ 12V
• Line Sense Relay
Option available
• Magnetic and Diode
option available
• Insulation Voltage up
to 4.25kVdc
• Variants UL approved
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
31
high voltage reed relays
Contact Form A/dry A/d ry A/d ry
Rated Power max W 15 10 5
Switching Voltage max VDC 200 500 90
Switching Current max A 1,0 0,5 0,5
Carry Current A 1,25 1,0 1,0
Contact resistance max mohms 150 200 200
Breakdown Voltage (contact/contact) min VDC 250 1'500 100
Operate time incl. bounce ms 0,5 0,5 0,5
Release time ms 0,1 0,1 0,1
CONTACT CONDITIONS UNITS 02 05 11
Shock at 11ms max g 35
Vibration at 50-500Hz max g 20
OperatingTemperature °C -20/+70
Storage Temperature °C -35/+95
Isolation coil/contact min kV 1,5 DC (4,25 DC /3,0 AC at diagram 03L)
Insulation coil/contact min Gohms 100
Life expectancy Dependent upon load, consult sales office
Solder time/temperature max 10 sec,/260°C
Washability Fully Sealed
Data at 140% of the nominal voltage and 20°C. Other switches against inquiry.
RELAY CONDITIONS UNITS
5.00**** max
(0.196“)
3.5±0.20
(0.14") (0.008")
0.25
(0.10")
2.54
(0.10")
19.60* max
(0.78")
0.60 max
(0.023")
4.60 max
(0.18")
15.24
(0.60")
5.08 max
(0.20")
3.5±0.20
(0.14")(0.008")
0.25
(0.10")
Dimension with *(20.50 max)** (8.30 max) Magnetic screen(0.807") (0.33") (0.27") (0.24")
***(6.80 max) **** (6.00 max)
5.08
(0.20")
0.60 max
(0.023")
7.80** max
(0.31")
3.20 min
(0.126")
MECHANICAL
19.80* max
(0.78")
15.24
(0.60")
32
Custom Relay Selector
Contact Specifications
Number of Poles 1 Other 2 3 4
Contact Form normally open
Isolating Voltage
Across contacts (kV) _____________________ DC/peak AC/RMS*
Contact to Contact (kV - for multiple contact relays) _______________________ DC/peak AC/RMS*
Contact to Coil/Screen (kV) _________________ DC/peak AC/RMS*
Switched Power
Switching Voltage (kV) ____________________
Switching Current (A) _____________________
Total Switching Power (W) _________________
Contact Carrying Current (A) ________________ If not resistive please describe ________________
closed latching
Signal Type DC/AC ........... Hz
RF parameters: (dB or m
Insertion loss/ESR ____________ isolation (dB) __________ return loss (dB) ________________
Contact resistance (m
)
Coil Drive Specifications
Nominal Coil Voltage (V) 5
) __________________________________
Operating Voltage Range (V - if nominal voltage varies) ____________________________________
Maximum Coil Drive Current (A) ____________________________
12 24
General
Electrostatic Shielding?
Physical dimensions (mm) L__________ W__________ H
Mounting method PCB
Magnetic Shielding?
Temperature Range (
Panel Mount Flying Leads
C) ___________________ Shock and Vibration approvals ___________¡
Any other requirements? _____________________________________________________________
Briefly describe the application: _______________________________________________________
_________________________________________________________________________________
Customer Name: ______________________________ Position: _________________________________
Company Address: ______________________________________________________________________
______________________________________________________________________________________
Tel. No. _________________________ Fax No. _______________________ Date: _________________
Quantity required: ___________ Purchase date: ____________ Purchasing contact: _________________
*Delete as applicable
Circuit Diagram/Contact Form/pin layout
Please return to your local representative or fax directly to +44 (0) 1202 891918
Please photocopy,complete andreturn this formand Crydom willreview your customrequirements.Alternatively, fill inthe on-line form atwww.crydom.co.uk
CONTACT US NOWUNITED KINGDOMCRYDOM
+44 (0)1202 897969+44 (0)1202 [email protected]
USACRYDOM
+1 858 715 7200+1 858 715 [email protected]
E
F
T
W
E
F
T
our aim is to form closepartnerships withour customers,working with
levelsthem at all
Liquid Level Sensors
Liquid Flow Sensors
Fluid Control
Reed Switches
RF Reed Relays
High Voltage Reed Relays
General Purpose Reed Relays
DIP/SIP Reed Relays
Transformers
lnductors
Crydom Magnetics’ Product Portfolio
UNITED KINGDOMCRYDOM MAGNETICS LTD7 Cobham RoadFerndown Industrial EstateWimborneDorsetEngland BH21 7PEPhone: +44 (0) 1202 897969Fax: +44 (0) 1202 891918email: [email protected]:www.crydom.co.uk
USACRYDOM CORPORATION9525 Chesapeake DriveSan DiegoCA 92123USAPhone: +1 858 715 7200Fax: +1 858 715 7280e-mail: [email protected]: www.crydom.com
© 2000 CRYDOMEvery effort has been made to ensure that the information in this brochure isaccurate. Crydom is not responsible for printing/clerical errors or omissions.Specifications subject to change without prior notice.
Printed in UK - Design by Visual Assets. VA7670. 10.00 RR2000UK