37
2201 LOW COST NUCLEAR THERMAL ROCKET CERMET FUEL ELEMENT ENVIRONMENT TESTING (CFEET) David E. Bradley Nuclear Systems, NASA MSFC Huntsville, AL DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. https://ntrs.nasa.gov/search.jsp?R=20120002970 2020-07-28T08:28:16+00:00Z

search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

2201 LOW COST NUCLEAR THERMAL

ROCKET CERMET FUEL ELEMENT ENVIRONMENT TESTING (CFEET)

David E. Bradley

Nuclear Systems, NASA MSFC Huntsville, AL

DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.

https://ntrs.nasa.gov/search.jsp?R=20120002970 2020-07-28T08:28:16+00:00Z

Page 2: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Purpose of Test Hardware

• Low-Cost, small scale testing of NTR fuel element samples to obtain non-fissile materials data.

• Concentrated heating of fuel sample to near-prototypical temperatures (and expose to Hydrogen) to identify material failure modes.

• Allow for rapid turnaround testing of fuel elements manufactured using variety of materials and techniques.

Page 3: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Illustration of Test Setup

Vacuum Chamber

Fuel Element

Pyrometer Sight Glass RF Coil

Fuel Element Pedestal

Pyrometers

Page 4: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Test Setup Dimensions

Page 5: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

RF Coil, Fuel Element, Pyrometer Detail

Page 6: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Fuel Sample Pedestal Details

Page 7: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Vacuum Chamber Setup – front view

Analog Vacuum Gauge – since replaced

by digital sender.

Chamber Relief Valve

Pyrometer Sight Glass

Vacuum Chamber

RF Coil Feedthrough

Page 8: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Vacuum Chamber Setup – rear view

Chamber Relief Valve

Turbo Pump

Vacuum Chamber

Turbo Pump Isolation Valve

Roughing Pump (under table)

Pyrometer Sight Glass

Page 9: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

View Inside Vac Chamber Showing RF Coil

Page 10: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Non-Contact Pyrometers

Vacuum Chamber

Sight Glass

FAR Pyrometer Lens and Optical Fiber

Mikron M770S Pyrometer

Page 11: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

View Into Sight Glass During Heating Test

Temperature Scale Shown for Reference – NOT ACTUAL ELEMENT TEMPERATURE

* http://www.blksmth.com/heat_colors.htm

Page 12: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample

201106241306 winplot format.csv

Mik

ron

Pyro

met

er 8

00 -

1500

°C,F

AR P

yrom

eter

Low

800

- 25

00°C

,RF

Powe

r 0 -

15 k

WEd

it w/

men

u St

yle-

>Nom

encl

atur

e->S

et S

ub-T

itle

105 200 295 390 485 580 675 770

1200

1000

800

600

400

200

0

1200

1000

800

600

400

200

0

2.0

1.5

1.0

0.5

0.0

-0.5

-1.0

Time sec Mikron Pyro FAR Pyrom RF Power 0

WinPlot v4.50

1:43:18PM 06/24/2011

Mikron Pyrometer 800 - 150 FAR Pyrometer Low 800 - 2 RF Power 0 - 15 kW

RF Power

Mikron Pyrometer (Orange)

FAR Pyrometer (Green)

Page 13: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Pyrometer Viewport During Melt Test

Page 14: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Melt Test Videos

• melt test view 1.mp4 • melt test view 2.mp4

Page 15: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

304 Fuel Element in RF Coil Before and After Melt

Page 16: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Estimated RF Heating Efficiency during Melt Test, no shielding

Page 17: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Thermodynamic Modeling

• Using simple equations for conduction and thermal radiation heat transfer, heat loss rates were predicted.

• Conduction heat loss is proportional to the element temperature.

• Thermal radiation heat loss is proportional to the fourth power of element temperature.

• At higher operating temperatures, thermal radiation dominates.

Page 18: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Shielding Techniques

• Reducing thermal radiation heat loss from the fuel element to the vacuum chamber requires a shield of some kind.

• An Alumina ceramic insulator was fabricated to fit between the fuel element and the RF coil.

Page 19: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Alumina Sleeve Insulator as Installed

Page 20: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Alumina Sleeve Insulator during Test

Page 21: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Low Power Heating Tests, Element Temp During Heating

600

700

800

900

1000

1100

1200

1300

1400

0 60 120 180 240 300 360 420 480

Tem

pera

ture

(°C)

Time (seconds)

No insulation, vacuum pumps isolated.

With insulation, vacuum pumps isolated.

With insulation, vacuum pumps operating.

No insulation, vacuum pumps operating.

Page 22: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Low Power Heating Test, Element Temp During Cool Down

500

600

700

800

900

1000

1100

1200

0 60 120 180 240 300 360 420 480 540 600

Tem

pera

ture

(°C)

Time (seconds)

No insulation, vacuum pumps isolated.

With insulation, vacuum pumps isolated.

With insulation, vacuum pumps operating.

No insulation, vacuum pumps operating.

Page 23: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

High Power Heating Tests

• Some estimate of maximum system performance was desired.

• An in-coil ceramic insulator provided potential gains in heating efficiency.

• A heavier wall Zirconia ceramic insulator was cast and installed around a high-melting point cermet surrogate fuel element for this testing.

Page 24: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Cermet Surrogate Fuel Element Specifications

• W: Tungsten, 63% by weight, Cp=132 J/Kg ∙K, MP=3422 °C • Rh: Rhenium, 5% by weight, Cp=136 J/Kg∙K, MP=3186 °C • HfN: Hafnium Nitride, 32% by weight, Cp≈249 J/Kg∙K, MP=

3305 °C • Sample Mass: 92.881 g • Estimated properties (based on mass percentages): Cp=169.8

J/Kg∙K, MP=3373 °C • Dimensions: ½ in. in diameter x 1.5 in. in length • Sample Density: 19.2 g/cm3

Page 25: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

RF Coil, Fuel Element and Insulator Setup for High Power Test

Note hole in ceramic insulator for pyrometer temperature measurement.

Page 26: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Time Lapse Photos of High Power Test

Page 27: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

High Power Test Video

• high power test with W-Rh-HfN.mp4

Page 28: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

High Power Heating Fuel Element Temperature Plot

500

1000

1500

2000

2500

38:58.3 41:58.3 44:58.3 47:58.3 50:58.3 53:58.3

Tem

pera

ture

(°C)

Time (mm:ss.s)

FAR Internal Data

Mikron Pyrometer Data

Page 29: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

High Power Testing Results and Discussion

• RF Power supply tripped off on high water temperature limit (40°C).

• Water temperature dropped sufficiently to resume heating after about 60 seconds.

• Maximum fuel element temperature achieved: 1931°C

• Heating was limited by a cooling water limit and not insufficient heating power.

Page 30: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

High Power Testing Results and Discussion (continued)

• The hardware was observed post-test and physical contact between the in-coil insulator and the water-cooled RF coil was detected.

• Excessive conduction of heat from ceramic insulator to cooling water most likely cause of high water temperature trip.

• Eliminating physical contact and increasing cooling water flow rate should preclude further high temperature water trip.

Page 31: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

System Upgrades – Water Supply

Custom 6” CONFLAT™ RF Power Feed-through

New RF Coil with 3/8” diameter Copper Tubing

Page 32: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

System Upgrades – New Ceramic Insulator with Clearance Fit to Coil

New RF Coil with 3/8” diameter Copper Tubing

New Two-Piece Ceramic Casting: Improves Stress Relief Due to Thermal Expansion

Cermet Sample

Page 33: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Upcoming Future Work • Integrate new and upgraded components into system. • Install thermocouples on vacuum chamber outer wall. • Run system check-out and ceramic bake-out tests using stainless

steel sample. • Run identical heating power profiles with all available combinations

of insulation/shielding. • Install Tungsten/Rhenium/Hafnium sample in chamber. • Bake-out ceramics pulling active vacuum. • Hard bolt chamber top flange, pull deepest possible vacuum and

isolate pumps (observe vacuum decay). • Test to highest possible fuel sample temperature or to system

failure whichever comes first.

Page 34: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

BACKUP CHARTS

Page 35: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

RF Power Supply Specs

• Radyne Flexitune +15 2-255750-001 • 15kW, 150 VAC, 2400A, 20-60kHz

Page 36: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

FAR Full Spectrum Pyrometer Specs

• Temperature range – FMP2: 800 - 2500°C nominal; lower limit is dependent upon the absorption of

the optical path and emissivity of the target. – FMP2x: 2000 - 4000°C nominal.

• Resolution: 0.1°C • Repeatability: 0.015% • Accuracy: 0.15% on gray targets; typically better than 0.75%

on targets with nongray or changing emissivity or with absorbing atmospheres

• Wavelength range – 500 - 1000 nanometers

Page 37: search.jsp?R=20120002970 2020-06-17T09:05:53+00:00Z 2201 ... · Data Plot from 1.5kW Non-Melt Test of 308 stainless steel sample Mikron Pyrometer 800 - 1500°C,FAR Pyrometer Low 800

Mikron M770S Pyrometer Specs

• Temperature Range, 600 – 1400°C • Accuracy: ±0.5% of full scale span • Repeatability: 0.1% of full scale span • Temperature Resolution: 1 °C/°F • Spectral Response: One or two narrow bands near

infrared