R 9.0.0 Release Notes Preface A further CADISON release is available with the present CADISON Version. Extensive new developments and further processing, special customer development and error correction has been under taken since the release 8.6.0. The new CADISON functions must be known before the use by users and the CADISON system administrators , since with this an appropriate use of important changes can be under taken in the projects. This document can also be found in PDF format on our internet site: http://www.cadison.com/Customers_Care/Updates.aspx

R 9.0.0 Release Notes - CADISON · CADISON R9.0.0 Release Notes ISOGEN ISOGEN-Licenses Impact of MLD entries for ISOGEN-piece list Additional MLD features for elements of a screw

Embed Size (px)

Citation preview

R 9.0.0

Release Notes

Preface

A further CADISON release is available with the present CADISON Version. Extensive newdevelopments and further processing, special customer development and error correctionhas been under taken since the release 8.6.0.

The new CADISON functions must be known before the use by users and the CADISONsystem administrators, since with this an appropriate use of important changes can beunder taken in the projects.

This document can also be found in PDF format on our internet site:

http://www.cadison.com/Customers_Care/Updates.aspx

2

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Inhaltsverzeichnis

CADISON R9.0.0 Release Notes 3Installation 4Overview of new functions 6Overview of function changes 9Overview of Bug fixes 14CADISON general 21 General 21 ACIS-Converter 32 Archiver 33 Report generator 34 Object model 36Designer 39 Designer General 39 PID-Designer 46 3D-Designer 48 Electric-Designer 51 ISOGEN 52 Visio PID 54Project-Engineer 57MATPIPE 60 Selector 66Project-Navigator 67Engineer2Web 68Administration 69 General 69 ITFTOOLS 71 API 73Conclusive Information 74

3

ITandFactory GmbH

CADISON R9.0.0 Release Notes

CADISON R9.0.0 Release Notes

Module Internetressourcen

Changes in CADISON:General | ACIS-converter | Archiver | Reportgenerator | Object model

www.cadison.com

Changes in CADISON Designer:General | P&ID-Designer | 3D-Designer |Electric-Designer | ISOGEN

Support:

FAQHotlineTrainingChanges in Project-Engineer

Changes in MATPIPE

Changes im Project-Navigator

Changes in Engineer2Web

Neu!New functions | Changes functions | Bugfixes

Admin General | ITFTOOLS | API

Copyright 2009, ITandFactory GmbHDate: 01.12.2009

ITandFactory GmbHAuf der Krautweide 32D-65812 Bad Soden

4

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Installation

Prerequisites

Please read the installation instructions before installation.Further information is found under "Installation requirements" in the document availableon the installation-DVD: "CADISON_Installation.pdf".

Updating existing installations

Category: AdministrationPlease read the installation instructions beforehand.Further information is found under "Notes regarding update installation" in documentavailable on the installation-DVD: "CADISON_Installation.pdf".

The actual installation

Category: AdministrationPlease read the installation instructions beforehand. Further information is found under "Installation procedure" in the document available onthe installation-DVD: "CADISON_Installation.pdf".

Re-installation of CADISON R9.0

Please read the installation instructions beforehand. Further information is found on the installation-DVD: "CADISON_Installation.pdf".

Subsequent installation / uninstalling of a module

The setup supports the subsequent installation and thus the uninstalling of a module.The setup "CADISON" can be started through "Start > Settings > Control Panel > Add orremove programs" and "Change" can be selected. Please read the installation instructionsbeforehand. Further information is found in the document available on the installation-DVD:"CADISON_Installation.pdf".

Installing the network license manager (NLM)

Start the setup under NLM\Setup.exe from the CADISON R9 DVD.Further information is found in document available on the installation-DVD:"CADISON_Licensemanager.pdf".

5

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Licensing

Catagory: AdministrationFurther information is found in the document available on the installation DVD:"CADISON_Licensemanager.pdf".

Scope of delivery

Along with the delivery of CADISON R9.0, you receive:

A program-DVD CADISON Release R9.0 A DVD with customised customer object model Release notes CADISON R9.0 (as PDF and CHM on the DVD)

6

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Overview of new functions

CADISON General

Units with unicode signs/ special signs

Define a pattern object with alternative graphic

Request of the features from the revision documents

Internal file name comparison now not depending on small and capital wiriting

New functions for tables and column filters

Sub-divide other objects in CADISON table

Table dialouge can now been displayed internally in additonal columns

Archiver

New storing options

Report generator

New keyword SUMHIDE for word report generator

CADISON Project-Engineer

Entering files and emails using DragAndDrop

MATPIPE

Reference of LINK-Objects in formula

Copy catalouge

Open dialouge box anew

7

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Update all duplicate objects

Language neutral attributes

Backup of sub-directories

User log in und user rights in MATPIPE

The search function in MATPIPE and Selector

Export and Import of a catalouge

Name and description for configuration

Process and change configuration

Updating configurations

Selector

Display of selected configuration

Load the current catalouge status

General administration

Renaming the users

Changing the GROUP.FLG files and unicode-Systems

Recreate GROUP.FLG correctly

ITF-Tools

Correction of dupilicate connecting points

ITF Dialouge box

New option -RESOLVEDEADTRANSACTION [Log-file]

New Option -DELDBSINRB [Log-file]

New Option -TRANSFERDOCS

8

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Engineer2Web

Engineer2Web view of DWG and DXF files

9

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Overview of function changes

CADISON General

Scroll bars in filter selection lists

Filter line in ListFromFile-selection dialogue

Selection of user defined table configuration

New selection window for the date

Background colors of the filter selection list in the table

Memory optimisation in case of several changes

Display of the project name in search result

Copying the memo texts

PDF-generation from XLS-files

New Versant Version

PDF-generation for new Microsoft Office file formats

"Cancel"-button in CADISON Tree-Dialogue

Display of the attribute "P_project"

Filling and numbering of unit fields

Takeover of a dictionary entry

Simultaneous read access to Unicode-files

Automatic re-filtering in case of change to a column filter

Issue of "Object description" in case of object locks

Takeover of column width in dialogue "Modify table configuration"

New function "Set property to default value"

Size of the selection list in case of table filter

Allocating and removing catalogue entries in case of locked objects

ACIS-converter

Undesired file name

10

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Report generator

FILTERSUB with sub-ordinate components

Object model

Allocation of transmitter, transducer and devices to pipe

New default value of feature SETVISIBILITY

EX-features in case of object types PHI-ROOM and PHI-REGI

Heat changer, max 10KW

Min-value in case of temperature sepcifications changed to 273.15

Properties for drop in pressure calculation, Lambda-value is entered

Properties for drop in pressure calculation, Zeta value is entered

Type classes entered in case of „Valve [straight]" [PHI-PVLS]

Designer general

Sorting in dialogue "Object Designation"

Input of DWG-file names in symbol editor

"Merge objects" does not combine any labels

Problems while accessing character elements

Conversion of container assistants from VBA --> C++

Updating all currently loaded characters

Display of definition of configured labels

Highlighting function from the tree and the table that is to be docked

Data from / data to

Property ATTEXCHANGE not any longer dependent on case

11

ITandFactory GmbH

CADISON R9.0.0 Release Notes

3D-Designer

Segment curve

Flangs and coils were not correctly exchanged while changing the nominal diameter

Highlighting a 3D-graphic shows the diagram as a seperate point

Counter in section name

Extrusion while conversion in bent pipe

CADISON Project-Engineer

Selection of a display configuration in case of active table parts

Display of write protected MEMO-features in the table

New system error message

MATPIPE

Coloring of configurable duplicate objects in Matpipe-Tree

Input field enlarged

Log in name in CCC

Upgrading the processing of design specifications

Sorting the attributes in the main table

Retaining the object codes while changing the links

Commands for storing the configurations

ITF-Tools

Clearing up of unused graphical representations

12

ITandFactory GmbH

CADISON R9.0.0 Release Notes

ISOGEN

ISOGEN-Licenses

Impact of MLD entries for ISOGEN-piece list

Additional MLD features for elements of a screw type

Engineer2Web

Engineer2Web Timeout Problem

Visio PID

Performance optimization

Arbeiten mit mehreren Zeichnungen gleichzeitig

"Nächste" und "Vorherige" - Zeichnung Schaltfläche zum Wechsel zwischen den Zeichnungen

Baukasten

Rückgängig machen

Grafik austauschen

Copy&Paste zeichnungsübergreifend

Konfigurierbare Strukturansicht

Rohrleitungsfarbe und -Typ medienabhängig

Objekt in Rohrleitung bewegen

RGB Farbzuordnung, benutzerdefinierte Linientypen und benutzerdefinierteFließrichtungssymbole

.def Dateierstellung im Befehl "Neues Symbol erzeugen"

Erstellung einer benutzerdefinierten Anlage

13

ITandFactory GmbH

CADISON R9.0.0 Release Notes

ObjectInspector

Zeichnungen Synchonisieren

Objekt Skalieren Befehl

Neuer Separator im Befehl der Objekt Kennzeichnung

Design-Checker Befehl versteckt die Objekte nicht durchgehend

Hilfedatei kann nicht geöffnet werden

Das Auswählen mehrerer Verbindungspunkte für ein neues Symbol war nicht möglich

Leitung fortführen Dialog zeigte nicht die korrekten Rohrleitungsdurchmesser

Beibehalten der Flächen Verbindungen

14

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Overview of Bug fixes

CADISON general

Importing existing characters as HookUp's

Abnormal end while selecting a deleted object

Unicode- database conversion

Blank session after integration

Input of a unit in dialogue "process attribute"

Abnormal end while generating report with unnamed property

Unicode characters in the selection list of the table headings

No icons in Tree in selector

Search in Tree

Abnormal end while importing existing documents

Excluded working copy cannot be incorporated

Abnormal end after unlocking the computer

Aborting the function "Attach catalog item"

Filter on "undefined" in table

Dialogue for "Find object..."

Incorrect display in selection list

File name "<<overwritten>>"

Text in waiting dialogue during the license test

Unicode-dictionary

Abnormal end while using the copy option "Reset document reversion"

"Check out to Working Copy" outsources several characters

Selecting a display configuration does not change the Tree-text of the project

Calculation of DNMAX in case of pipelines

Problem with Unicode in the ConfigManager-Dialogue box

Entries of file enhancements in CADISON.INI

Character revisions while incorporating

15

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Updating the project object in CADISON-Tree

Abnormal end in case of opened Matpipe selector

Changing the column width in the CADISON table

Icon in title list of Memo-process-dialogue

Incorrect filter in table without class selection

Problems in case of huge project data with several objects

Resetting the order number

ACIS-converter

Abnormal end while converting flanges and dished boiler ends

Freezing of AutoCAD while converting N-edges

Archiever

Files are reconverted to "Transfered to database" while archiving

Change of the database project directory through archiving

Report generator

AutoCAD-command "Publish"

Report pattern with use of a wildcard property filter

Hanging of Word while creating / updating reports

The dialogue "Server is busy" while creating reports

Old report cannot be updated

Release of P_name in report

Object model

Incorrect text for ISOGEN-connection types MP and LN

16

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Feature SALES_PRICE is calculated

Designer general

Problem with creating the active field while working with XREF

Duplicating connection points by using Copy&Paste

Copying/renaming dialogue after character verification

No SLD files creating symbols

Overwriting file as per "Save as"

Duplicate characters as per "Save as"

Elements are stored in incorrect layer

Duplicate copy dialogue while copying objects

Abnormal end during labelling

"Create revision table" shifts plot mode

Entering a file name in case of "Save as"

Bent pipe cannot be labelled with block and leader

Updating graphics while loading characters

Abnormal end of designer after moving a symbol

Infinite loops after processing a block

Graphics do not change as per "Copy Data from / Copy Data to"

Exceeding maximum number of selection sets

Changes to graphic of objects in loaded characters

Abnormal end while "Rotate object in line"

Symbols in characters change as per update on R8

Selection of a writing field while plotting

Loading the AutoCAD-Architectural-Functions

Leader of the text screen labelling is not drawn in the selected form

Creation of modules

Creating PDF- for DWG-files

17

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Route look up in character adjustment

Highlighting in layout

Creating section in Russian AutoCAD-Version

Incorrect presentation of graphic as per "Move object in piperun or line"

Change in the flow direction deletes the database objects

Updating Excel-Reports

Error message "Unsupported event" while batch plotting

Incorrect result display in consistency test

Create a standard in dispaly window / in case of section

P&ID-Designer

Color of the leader changes while copying the layout

Character with MPL-line shows errors while opening

There is no flow direction arrow in case of MPL-pipelines

Error with the connection on end cap

Graphic variants swap with unsupported elements

Error in case of "Create visible pipe crossings"

Unicode sign within MPL style

3D-Designer

ISOGEN Layout-object and start point object hampers centre allocation

Bent pipe is generated with remarkable geometry

Bent pipe with incline

Selection of read files in XREF-Manager

Abnormal ending of AutoCAD while updating / exporting of 3D-elements

Abnormal end while labelling with block

18

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Incorrect presentation of "New" primitive

Error in case of presentation and ACIS-converting of N-Edge MATPIPE-Primitive

Matpipe-Elements were no longer displayed in 3D-Mode

Abnormal end while drawing pipes

3D-display of wrongly parametrised Matpipe-Elements in Designer

Pulling the elements "Duct transition rectangular/round"

Electric-Designer

Display of graphic in dialogue "Allocate measuring point typical"

Error message in case of invalid object selection

Creation of HookUps

VBA-function "Batch processing of contact sets" replaced by C++ function

CADISON Project-Engineer

Adjustments for AKH - multiple Windows

On closing the window, parts of the symbol list disappear

Abnormal end while updating CADISON tree

Login-Dialogue appears on highlighting the object

Changeover between windows changes the structure view

Faulty menu and tool bar after incorporation

Changing the width of table column

Sorting in ascending order in the last column

Activating the table parts

Missing context menu for EDITABLEONETIME features in tables

Help button is referred to a wrong path

19

ITandFactory GmbH

CADISON R9.0.0 Release Notes

MATPIPE

Importing '999999999' from CSV-files

Display of links not selected while configurations

Cyrillic signs in parametric module

Duplication of duplicates

Field ReplicaID_ not filled in TGfxObject

Transfer problems of graphic parameters while replicating objects

Storing of configurations with CONFIGOBJ

Faulty error message in parametric module

Problem with opening of a second catalogue

Sorting in MATPIPE Report generator

Updating problem in MATPIPE Tree

Drag & Drop error in MATPIPE Tree

Abnormal end of program

Project-Navigator

Enter catalogue object

Administration general

Reading the variable "PHI_CONFIGPATH" in the correct sequence

Reading the variable PHI_CONFIGPATH

Abnormal ending of conversion tools in case of simultaneous conversion of several databases

Query of the user

NOMAT is marked as INVALID by DEFREAD

Option "Convert databases" in program UpdateDbs

20

ITandFactory GmbH

CADISON R9.0.0 Release Notes

ISOGEN

Abnormal end of the MLD-Editor

Extrusions on bent pipes in isometry

Creation and updating / revising isometric drawings

Feedback of ISOGEN position number as per CADISON

Engineer2Web

Special signs in dialogue "Über..."

API

Setting of feature values using CADISON API

21

ITandFactory GmbH

CADISON R9.0.0 Release Notes

CADISON general

General

New functions

#22405Units with Unicode sings / special signs

So far only the west European signs could be used for description of units (like e.g."Meter"). After this version it is also possible to use special signs or Unicode signs.

Note: It was necessary to change the internal database for this functionality. Due tothis reason, the existing databases must be first converted in the R9 database format.This conversion takes place automatically or the conversion program "Convertdatabases" can be used for that.

Definig a document object with alternative graphic

After this version CADISON is in the position to select an object graphic depending on anyproperties. Several graphics can be stored for one drawing type in case of one documentobject, and based on any one of the freely defined properties, CADISON can automaticallyuse one the graphics.

#21052Question of feature of revision documents

After this version, in case of documents, CAD drawings and reports, the following newproperties are available:

o P_lastrevisiono P_lastrevisiondateo P_lastrevisiondatetime und o P_lastrevisionuser

If in case of one the document object, the value of one of these properties is questioned,then all attached revision documents are determined internally from the document object.These are sorted as per date of creation (Property P_creationdatetime). The respectivefeature is returned from the last created revision date:

o P_lastrevision returns REVISION of last revision document.o P_lastrevisiondate Returns P_creationdate of last revision document.o P_lastrevisiondatetime returns P_creationdatetime from the last revision

document.o P_lastrevisionuser returns P_creationuser from the last revision document.

#22661Internal file name comparison is now case sensitive

CADISON internally sets a file name, sometimes only in upper case, sometimes lower

22

ITandFactory GmbH

CADISON R9.0.0 Release Notes

case, as it has been entered by the user (or as already available). In case of internal filename comparison, CADISON had evaluated the internally set file names differently andtherefore saves the new names, which pulls back further updates. Now at this point thename comparison is carried out irrespective of case.

New functions for tables and column filter

Some enhancements for the column filter / table filter are reconverted in the main table ofCADISON project engineer. For one, a list of three of the last used filters is directed per column. The last used filters are displayed in the selection list under the entries "All","Userdefined", "Empty" and "Not empty". If "Userdefined" is selected then automatically the last set filter, defined by the user isdisplayed in the dialog for definition of user defined filter, If in case this is still listed in thelist with three of the last used filters.

"Activate table filter" on: This entry in the context menu is provided with hook, if a filter isactive.

the hooks are removed while selecting the command and all filters in the table are reset. Thereby, which columns were filtered is stored (The names of the properties are stored). If this command is accessed again, then these columns are filtered anew. If the propertiesto be filtered are not present in the current table configurations then they are ignored.If a user defined filter is created, then this appears in the list of the last used filters with asyntax from which the parameter of the user defined filters are visible. The list of the last used column filter and the property name of all currently filteredcolumns is stored in the LocalCFG-folder in the file last.cpf.

#22507Other object sub-ordinated in the CADISON table

So far the command "Attach to another object..." was available only in context menu ofthe CADISON Trees or in extra menu of CADISON Project-Engineer. After this version, thiscommand can also be used from the context menu of CADISON table.

Table dialog can now be displayed in additional internal columns

Normally the columns to be displayed are specified in the table-dialog of the tableconfigurations. Now internally it is made possible to add additional columns per programming, at the startof the table.All other table functions must be by-passed. For example, these additional columns are not displayed when the current tableconfigurations are processed with "Configure table...".

Function changes

Scroll bars in filter selection lists

After this version, a horizontal scroll bar is displayed in the selection lists of the columnfilter, if the entries of filter lists are wider than the selection window.

23

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Filter lines in ListFromFile-selection dialog

The handling of filter lines in selection dialog of ListFromFile-feature has been changed.Filters are work only after second entered letter. Thus a long list can be filtered quickly.Additionally the filtration is optimized so that longer lists are filtered quickly.

#21241Selection of user defined table configurations

If a table is available in a dialog, a user defined table configuration is selected in thistable. Then the name of the selected configuration is stored on the computer permanently.The list of previously selected configuration appears at the start of the next dialog.

#21184New selection window for the date

After this version, a new window is used for selecting the date while processing the datefields. Furthermore, the window which shows the calendar is displayed in better way inWindows Vista.

Background color of filter selection list in table

After this version, the entries in the filter selection list of a table column is presented withdifferent background colors. The fixed entries like e.g. "All", "Userdefined" are displayed inlight grey background, the entries of the last used filters in dark grey and the standardentry in white background.

#22020Display of project name in search result

If specific objects are searched with the function "Find object..." using several projects /databases and the search result has objects of several projects / databases, then thesearch result is displayed in the table dialog, the name of the project is displayed in thefirst column.

Copying the memo text

While copying the memo text, internal control signs can be changed using the Memo-process-dialog in CADISON. If the original text e.g. contains only the control sign 10 for anumber change, the this is copied and entered in other memo-feature (Likewise againusing the memo-process-dialog), So far the number change is automatically changed tocontrol sign 13 and 10. This could lead to problems in a separate object comparison inCADISON.After this version, the clipboard is corrected in this reference. If a text is copied from theMemo-process-dialog and the memo-process-dialog is closed an automatic adjustment ofthe text is carried out in CADISON - clipboard. If a different memo-process-dialog isaccessed and the text is added from the clip board, then the original text is receivedwithout any changes.

PDF-Generation of XLS-files

24

ITandFactory GmbH

CADISON R9.0.0 Release Notes

After this version, the spread sheet "CADISON_SYS" is ignored while creating PDF filesfrom the XLS-files. The "CADISON_SYS"-spread sheet is automatically created byCADISON. While using the Excel report generator has the parameters of report generator.This information is not required in case of PDF-file and hence it is no longer present thePDF-file after this version.

Break the connection to database

There is always an active database in Versant, which is within the Versant database (notto be confused with CADISON defdb). Sometimes the connection to the default database isbroken by the system. Later this can take of internal error messages in CADISON.Therefore, a change was given here. If in case the system breaks the connection to thedefault database, then the system reconverts the Versant default database to CADISONdefdb um. Thus no more errors are actuated later.

New Versant Version

After this version, CADISON uses Versant 7.0.1.4 with patch 12.

PDF-creation for new Microsoft Office file formats

After this version it is possible to create new Microsoft office file formats ".docx" and ".xlsx" by CADISON PDF files.

#20906"Abort"-button in CADISON Tree-Dialog

If a CADISON-command for creating object selection displays the CADISON tree dialog,then there was a possibility to break the object selection since the dialog does not have aabort button or a close button. After this version, an "Abort"-button is available for mostof the commands which use the tree-dialog for object selection. Thus the CADISON-command can be aborted.

Display of attribute "P_project"

All objects return the project name for the attribute "P_project", where the objects belong.If this attribute is added manually in a table configuration file then so far this attribute isdisplayed as editable, even tough changes have not been stored. After this version theattribute is no longer displayed as editable.

Filling and numbering the unit fields

When so far, the filling and numbering dialog was accessed for unit properties, then thedialog offered only a new input line for entering a new value. No units were displayed. Sofar the user was to enter the used un it manually.Through the available update, one receives one more selection list for the units in dialogin addition to the input lines for the value, whereby the basis unit has already been set. Ifa value is entered and subsequently the unit is changed, then automatically the enteredvalue is recalculated.

Note: With the recalculation, the entered value is displayed with a different numberwith decimal places.

25

ITandFactory GmbH

CADISON R9.0.0 Release Notes

#20411Takeover of a dictionary entry

If in dialog "Language support" an entry is taken over as per CADISON and the entry endswith a space, then the space at the end is automatically removed after this version.

Simultaneous read access on Unicode-files

If CADISON has a reading access to the text files, then this happens in so-called Sharemode, so that several CADISON-applications can be read simultaneously in the same files(Like e.g. the central configuration files). This share mode however does not work if itdealt with a Unicode text file in case of file which is to be read. The error has beenresolved.

Automatic re-filtering while changing a column filter

If in the table several columns have been filtered and one column filter is removed, thenin the previous versions (before R8.5) all currently filtered columns were filtered again. Sofar only the column was re-filtered in R8.5, where the filter was removed. Thus, it couldhave happened that the content was displayed in other filtered columns, which were notaccording to the current filter.The performance is changed through this update. As soon as a column filter is changed(not only when it is removed), all the currently delivered columns are automatically re-valuated. Thus, the display is correct anytime.

#21840Issue of "Object description" in case of object locks

If a database object cannot be locked for processing, then information about this object isdisplayed in dialog information. After this version, the objects labeling is displayedadditionally, if the objects have the information.

#21189Take over of column width in the dialog "Modify table configuration"

After this version, the current column width is taken over while accessing the function"Configure table..." in dialog "Modify table configuration". So far the column width wasdisplayed in dialog, how it was originally defined for table configuration.

New function "Set property to default value"

There is a new command "Set property to default value" in the context menu for a feature.If this command is accessed, then the selected feature is reset to default value, as it isstored in the object model.If only one object is marked (in a table), the context menu entry is displayed only if theselected attribute does not match the default value. If several objects are selected in onetable, then the command is displayed in the context menu.

Size of the selection list in case of the table filters

The selection list displays maximum 8 entries in the table filters. After this version theheight of the selection list is directed as per the size of the table. If the table is high

26

ITandFactory GmbH

CADISON R9.0.0 Release Notes

enough, then up tp 30 entries can be displayed in the selection list. If the table height isless then the size of the selection list is adjusted automatically (reduced).

Allocating and removing catalog entries in case of locked objects

After this version, in case of locked objects (e.g. locked using the command "WorkingCopy - Add object-locks within the database" no more catalog entries can be removed orallocated.If the context menu is accessed on a separate object, then the commands are de-activated in the context menu. If the context menu is accessed on several objects in thetable, then commands are available, however no action is taken in case of locked objects.

Bug fixes

#23676Importing existing drawings as HookUp's

So far, if using a command "Import existing documents", it was attempted to create aHookUp-drawing, then a red color cross was found in CADISON tree for the newly createddrawing. This error has been resolved.

Abnormal end while selecting a deleted object

It may happen that an object is displayed in a CADISON application, CADISON tree ortable, which is already deleted in a different CADISON application. As soon as this deletedobject is clicked a message appears saying that the object has been deleted.In very rare cases it could happen that CADISON ends abnormally instead of showing thismessage. This error has been resolved.

Unicode-Database conversion

In rare cases there could be problems with the Unicode-conversion of old data. Especiallyin case of databases which were present in outsourcing / integration, it may happen thatthe Unicode conversion was aborted by an error.

Blank setting after integration

In some cases it may happen that a blank outsourcing setting is displayed afterincorporating in the original database. This error has been resolved.

Input of a unit in dialog "Edit attribute"

The dialog "Edit attribute" is opened using the function "Change attribute for this objectonly...". A different display unit can be selected in this. In previous versions it waspossible to enter a completely new text. If this text is not defined in CADISON as a unit,the CADISON can no longer execute any recalculations.Because of this reason, after this version, new text cannot be entered in the selection listbut only the existing units can be selected.

27

ITandFactory GmbH

CADISON R9.0.0 Release Notes

#21963Abnormal end while generating reports with unnamed property

If an Excel-Report is started on an object, which contains unnamed property, then thereport generator ends abnormally. This error has been resolved.

#22262Unicode signs in the selection list of table heading

In some of CADISON-Dialogs an old version of CADISON is used. The selection list of thesetables, which were available in the title of the tables using Drop down lists, were usingolder signs. This cannot show any Unicode signs.After this version, the same signs were used for the selection lists, which is also used forthe tables. Thus Unicode signs were also displayed in selection lists.

No icons in tree selector

While accessing the CADISON CCC-test, as a first function followed by opening of theselector and display of catalogs which was used last during the CCC test, the Icons in thetree of the selector are not correctly displayed. This error has been resolved.

#22258Search in Tree

The search function in CADISON Tree had only worked for the Tree function, where thesearch function was accessed the first time. If e.g. several tree windows have beenopened in CADISON Project-Engineer, the search works only for that window which wasfirst started in the search functions. After this version, the search works in tree for allwindows.

#22273Abnormal end while importing existing documents

CADISON could end abnormally while using the context menu command "Import existingdocuments", if this command was used more than once. As long as no project databasewas opened, CADISON ends abnormally while using the command the second. If a projectdatabase was opened, this command was accessed and subsequently exchanged on theproject, the a fresh access of the command could lead to abnormal end. After this version,the command can be used with any problems.

#22495Outsourced spread sheet cannot be integrated

If an outsourced database is operated on several computers before integration, then onlythe data of first operation can be integrated. In existing versions the integration processused to freezes while the complete setting was deleted. After this version, the changes tothe first operation are integrated and the other operations are ignored so that at least thesetting in the source database is deleted.

#22092Abnormal end after unlocking the computer

28

ITandFactory GmbH

CADISON R9.0.0 Release Notes

When CADISON Project-Engineer starts CADISON PDM or CADISON Project-Navigator,then a CADISON login-screen appears. If at this point the computer is locked, thenCADISON ends abnormally without logging in and subsequently unlocking in CADISON.This error has been resolved.

#21647Aborting the function "Attach catalog item"

When the function "Attach catalog item" was used for an object which already containssub-elements, then CADISON asks if the existing sub-objects are to be deleted. There arethree options in the question dialog "Yes", "No" and "Cancel". In the existing versions theoption "Cancel" was reconverted as "No". The process could not be aborted. Afert thisversion, the process of catalog allocation can be aborted by selecting this option.

#21620Filter on "undefined" in table

If in a column the user defined filter was processed and thereby the filter value "--" wasselected, in most cases the filtering did not work correctly. After this version, the filteringis executed correctly on "undefined".

Dialog for "Find object..."Search routines can be stored and deleted in the dialog for object search. The safetyqueries or other notes did not have completed text till now, but only a code was given.After this version, the messages contain the complete text while deleting and addingsearch routines.

#23027Incorrect display in the selection list

If one CADISON feature is processed using a selection list, then it may happen that theavailable entries are wrongly displayed in the selection list. If the entry has a semi colon,then the entry is displayed as two entries. This error has been resolved.

#22661File name "<<overwritten>>"

If a document contains a file name in a project, which is already in used in the projectthen CADISON automatically sets this file name to "<<overwritten>>". After this versionthe text "[[overwritten]]" is used as the sign "<" und ">" [and] is not allowed to be usedas filename and therefore CADISON cannot change the file name. Due to this CADISONcould end abnormally.

#23052Text in waiting dialog during license test

Text was adjusted in CADISON project engineer, AutoCAD Designer and Visio Designer,which is displayed during the license test.

Unicode-dictionary

29

ITandFactory GmbH

CADISON R9.0.0 Release Notes

The dialog "Language support" allows CADISON to process the currently set dictionary. Forthis the buttons "Add the language", "Delete the language", "Insert entry" and "Deleteentry" are present the dialog. When in case of the current dictionary it deals with Unicodefile, then these buttons are not available. This error has been resolved.

#22661Abnormal end while using the copy option "Reset document revision"

If the current diagram revision was attached in Designer and copied with "Save as", acopy dialog appears. If the option "Reset document revision" is selected then Designer endabnormally. This error has been resolved.

#22949"Check out to Working copy" outsourced several drawings

While outsourcing the data it may happen that the drawings, which are not neededdirectly, have not been outsourced, in order to process the primary selected data. Afterthis version, all the indirectly connected drawings are no longer outsourced whileoutsourcing but just the direct ones.

Selecting a view configuration does not change the Tree-Text of the project

If a view configuration has been selected in tree or the table using context menu entry"Select configuration...", all display texts of the objects are updated according to thenewly selected configuration.Till now however the texts of the project object are not updated on the tree but alwaysUpdate Tree must be actuated by pressing F5. After this version the project-object text is immediately updated on selecting a different view configuration.

Calculation of DNMAX in case of pipelines

The feature DNMAX in case of pipelines determines the largest nominal diameter of allpipe runs. This does not work if the nominal diameter specifications were integral inchspecifications, like e.g. 20".

#23439Problems with UniCode in the ConfigManager-Dialog box

Unicode signs were not correctly displayed in the ConfigManager Dialog box. This errorhas been resolved in the current version.

Entries of file enhancement in CADISON.INI

If a file is opened with context menu command "Display file..." or "Open file..." fromCADISON, then CADISON searches a matching file enhancement in CADISON.INI. If noapplication key has been entered in case of document in CADISON (under the PropertyAPPLICATION_CD), then file enhancement is used. Thereby till now the file enhancementin CADISON.INI should have started with a point (like e.g. ".JPG"). After this version,point must not be entered.

#21607Drawing revisions while integration

30

ITandFactory GmbH

CADISON R9.0.0 Release Notes

If during outsourcing, a drawing revision is outsourced, then it is not taken back in theoriginal database while integrating the project (Since a revision is write protected and isnot allowed to be overwritten).Since CADISON R8.0.1 this drawing revision is left in setting, so that the settings cannotbe automatically deleted by CADISON after integration. This error has been resolved.

#21614Updating the project object in CADISON-Tree

If an object has been changed in CADISON, the display text of the object is automaticallyupdated for CADISON-Tree. This, however does not work for project features P_prjnumberand P_prjstate. If these features were used for the display text and the values of thesefeatures were changed, then till now the display text were not updated in tree.

#21262Abnormal end in case of opened matpipe selector

If the Matpipe selector was opened in Engineer and subsequently CADISON tree inEngineer is clicked in case of opened selector window, then CADISON 8.5 endsabnormally. This error has been resolved.

Changing the column width in CADISON table

In CADISON R8.5.x, in some functions, the tables were not correctly evaluated after somecolumns were moved through Drag and Drop. Thus the print function did not note thechanged columns in the table. There could be display problem even while activating anddeactivating the adding function, if some columns have been moved. These problems havebeen resolved.

Icon in title list of Memo-process-dialog

The Icon in the title list of the Memo-process- window has been drawn with an incorrectscale under Windows Vista. After this version the Icon is displayed with the correct pageratio.

#20850Incorrect filter in table without class selection

The filter does not work correctly if the table configuration was changed in a table wherethe class selection is not available. When the filter list was opened in a column, then thecontent of previous columns is displayed.

Problems with larger project databases with several objects

CADISON uses internally storage optimized function after a specific number of object in aproject database, in order to access the objects. These functions could cause severalproblems. So e.g. it may happen that the changes to project object were not written in thedatabase reliably or that CADISON ended abnormally with the error E3003. This error hasbeen resolved.

#20266

31

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Resetting the contract number

If a current order number has been set in a project then it was always automatically resetevery time new objects were entered. This error has been resolved.

32

ITandFactory GmbH

CADISON R9.0.0 Release Notes

ACIS-Converter

Function changes

#22789Undesired file name

When the ACIS converter is accessed, an option dialogue appears, where the parametercan be set. In case of entered file names, till now, always an entered file enhancement isremoved and replaced by ".sat" or ".dwg". After this version, ".sat" or ".dwg" is stillattached, if in case the entered file name does not end with this file enhancement. Thuseven the file names like "ausgabe.test.sat" can be generated.

Bug fixes

#22922Abnormal end while converting hoses and dished boiler end

The converter may crash when the ACIS-converter converts a character which containsthe hoses and dished boiler ends or angular curves. After this version, characters whichcontain these object types can be converted without any problems.

#23119Freezing of AutoCAD while converting N-corners

In rare cases, it may happen that the AutoCAD does not react anymore, if an N-corner isto be converted in ACIS-element. This problem was resolved in this version.

33

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Archiver

New functions

New archiving options

New options have been incorporated in Archiver. Now the following two additional entriesare supported in the configuration section [ITF_ARCHIV]:

[ITF_ARCHIV]ArchivFailedFolder=Archiving failed AutoExpireTimeInMonth=0 MaxSizeToExportInMB=0

If while archiving a database, an error occurs, then the database in CADISON tree ismoved in database group, which is entered in the line ArchivFailedFolder=, whereby thedatabase group is created manually.Using the AutoExpireTimeInMonth= it can be specified that the database is archivedautomatically. This database cannot be changed for the specified time. This option worksonly on the database server as the database server is directly checked for this purpose. Avalue of '0' (this means the default value) means that the Archiver does not search the olddatabase (Only the database from the Archive-folder is archived).The maximum size can be specified with the line MaxSizeToExportInMB. This line permitsa database with that it can be still archived. A value of '0' (which is the default value)means that the size is not limited.

Bug fixes

The files are reconverted to "Transfered to database" during archiving

The document was always automatically reconverted to "transfered to database" when itwas not read previously and if archiving a database, in case of a document, had problemsin reading or copying the file. There appears an error message that the document was notcopied and the archiving was aborted. However the document is subsequently on"transfered to database". The read status is no longer changed after this version.

Change of the database project folder through archiving

After archiving a database it is moved in CADISON-Tree (either in the database group forfaulty logs or in the recycle bin-database group). Thereby, till now the project folder waschanged by the database without however renaming the project folder. If project wasaccessed, CADISON was not able to find the project files. After this version the projectfolder of the database is no longer changed after archiving.

34

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Report generator

New functions

New keyword SUMHIDE for Word-Report generator

After this version the new keyword $SUMHIDE$ is available. This keyword adds up objectssame as the keyword $SUM$, however there is no output in the report. Thus, it is nolonger necessary to format the text "$SUM$" as "hidden" in the report form.

Function changes

#23298FILTERSUB with sub-ordinate components

A FILTERSUB can be defined using the "P_treeobjects" during report query. Using thisthose objects which do not have sub-objects of specified types can be removed. Until nowonly the sub-ordinated structure elements were searched. The FILTERSUB- part of thereport query was enhanced in this version so that even sub-ordinated components can besearched. The new syntax of FILTERSUB-share of the report query is:TYP_S1,TYP_S2,TYP_Sn:TYP_K1,TYP_K2,TYP_KnThe types of colon are searched as structure sub-element, while the types search thecolon as components -sub-elements.

Bug fixes

#19843AutoCAD-command "Publish"

If the AutoCAD-command "Publish" has been used when several drawings were loaded,then either a dialog with question - if the current drawing is to be copied or renamed, or adialog with note - already a file of same name is present, appears in designer.This error has been resolved in this version.

Report pattern with use of a Wildcard-Propertyfilter

It possible to use a property filter in a report pattern. It is possible to work with the wildcrads signs "*" and "?" within this filter. If these signs have been used, then the reportcould not have been created correctly. This error has been resolved through this update.

#23164Hanging of word while creating / updating reports

While using Office 2007 with SP1 / SP2 it may happen that word hangs and does not reactwhile creating a report. The performance dependend on the used report pattern. After thisversion, such a problem never occurs.

35

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Dialog "Server is busy" while creating report

While creating a report, it may happen that a dialog "Server is busy" is shown by theoperating system and thus report generation is interrupted. After this version, this dialogis disabled so that reports can be generated without interruption.

#22947Old report cannot be updated

When, in case of an old report the absolute path to report pattern originally used has beensaved in the feature VIEWTYPE, then it was not possible to update this report in CADISON.This error has been resolved. After this version, report can be updated but however report-replacement file REPORT.TPM is not noted.

#23299Issue of P_name in report

If in a report form, the report syntax "$P_project.P_name$" and also "$P_name$" is used,then the property "P_name" of the project is issued twice. This is generally applicable forall properties, which have been requested using "$P_project...$". This error has beenresolved.

36

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Object model

Funktion changes

Allocation transmitters, transducers and measuring devices to pipeline

Until now a transmitter/ tranducer/ measuring device were not automaticallysub-ordinated to pipeline, when such an object in flanged execution had been entered in a3-D pipeline. The allocation is executed automatically after this version.

#21630New default value of the feature SETVISIBILITY

The ground value for the feature SETVISIBILITY was changed from "Yes" to "No" in theuser adminstration. This was executed for user objects and also for user groups. After thisversion, explicit authorisations must be issued in the user adminsitration in order to givethe user an access to the functionalities of visibility control.

#21617EX-Features in case of object types PHI-ROOM and PHI-REGI

In case of these object types, the text of selection lists for feature EX_TCLASS(Temperature class) was changed.In addition to that the selection list of the feature EX_GROUP was enhanced to a newvalue and a new feature EX_GROUP_KEY was added. Furthermore the new featureEX_GROUP_KEY is used in the EX_IDENT formula.

Heat exchaning device, max 10KW

The maximum value for the object classe "Heat exchanger" (PHI-HEXC) was increased incase of the feature "Heat transmission power" (HEAT_PWR).

Min-value in case of temperature specification changed to 273.15

In case of all temperature specification, the minimum input value was set to -273,15°C

Properties for pressure drop calculation, Lambda-value entered

In case of the following object classes, the feature "Pipe friction coefficient (Lambda)"[VALUE_LAMBDA] was newly accepted:Pipe (PHI-PIPE), bent pipe (ITF-BNDP)

Properties for pressure drop calculation, Zeta-value entered

In case of the following object classes the feature "Resistance factor (Zeta)"[VALUE_ZETA] was newly accepted:Compressor (PHI-CMPR); Pumps (PHI-PUMP), Filter (PHI-STRN), Hose (PHI-PHOS), curve(PHI-PARC), T-piece (PHI-PTEE), four way connector (PHI-PCRO), reducer (PHI-PRED),

37

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Dev. RLT (PHI-PEQI), compensator (PHI-PCMP), Strainer (PHI-PFLT), fittings (corner)(PHI-PVLE), fitting (three way) (PHI-PVL3), fitting (four way) (PHI-PVL4), fitting (straight)(PHI-PVLS), Muffler(PHI-PSIL), connector (PHI-PFIT), Flange (PHI-PFLG), connectionelement (ITF-COUP), Bushing (PHI-PSCK), bushing (PHI-PCOP), Nippel (PHI-PNIP), Bolting(PHI-PJNT), Flange (PHI-PBRD), coil (PHI-PBND), Weldseam (PHI-PWLD), Couppling(PHI-PCON), fitting (Multiport) (PHI-PVLM), extrusion/outlet (PHI-POLT), Y-Stück(PHI-PYTE), device heating/cooling jacket (PHI-THEC), branch saddle(PHI-PSAD),connecting branch (PHI-PELT).

Type classes in case of "Valve [straight]" [PHI-PVLS] entered

In case of object class "Valve [straight]", the feature "Type Class" [TYPECLASS] was newlyaccepted:

following selection list is stored:Blocking fitting, straight;Blocking valve;Stop cock, general;Gate valve;Shut-off valve;Check valve, general;Check valve;Check valve;Fitting with constant adjustment characteristic;Fitting with safety function;Ventilation and exhaust fitting

The background of this adjustment is a differentiation for Matpipe selector. In order to beable to use this function, the following basic conditions are to be adhered to:

o The an_art.flt must be amended for the object class "Valve [straight]" to searchcriterion [TYPECLASS].

o The feature [TYPE CLASS] must be added as main entry and as per the catalogobject an entry must be selected from the selection list.

If the entry matches with "Valve [straight]" in Engineer with the catalog object, then therespective catalog object is displayed in the "Search result" tab of the selector.

Bug fixes

#22011Incorrect text for ISOGEN-connection types MP and LN

For the JOINTYPE-feature in CADISON, until now the ISOGEN-Option MP was displayedwith "Liner" and the option LN with "Male Part". This allocation is interchanged. After thisversion, for ISOGEN-option MP, the text "Male Part" is displayed and for option LN "Liner",exactly like it is documented in the CADISON ISOGEN help file.The actual database content remains unchanged. The inventry data is displayed only witha different text after a CADISON-Update on this version.

#21516Feature SALES_PRICE is calculated

38

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Until now, in case of object model "Commercial Extension" the feature [SALES_PRICE]"Sales price total" was not automatically calculated in case of all object types. Oneformula was stored in the object model, however the feature type EDITABLE is used. Afterthis version, the type CALCULATE is used, so that the sales price is calculatedautomatically.

39

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Designer

Designer General

Function changes

#21688Sorting in dialog "Object Designation"

The entries in the list of dialogs "Object Designation" and "Configured Designations" aresorted. Thereby, until now however the numbers in the entries were not sorted correctlye.g. "Userfield 10" before "Userfield 2". After this version the number were correctlysorted in the texts.

#22314Input of DWG-file name in symbol editor

In symbol editor in AutoCAD Designer, an input field is present for entering file names forthe graphic files for the symbols to be created. Until now maximum 8 characters could beentered. After this version, up to 200 characters can be entered in the field.

#20570"Merge objects" does not merge labels

If an object has been labeled and then processed with Designer-command "Mergeobjects", then the original object is deleted, since the labeling has not been transferred tothe objects to be merged.If the command "Merge objects" has been accessed from the Engineer, then the labeling isautomatically merged.

Reconversion of the container assistant from VBA --> C++

The container assistant has been implemented in AutoCAD under VBA. Since all sourceshave been reconverted to C++ and MFC, now only the container assistant was in line.In container assistant, it is possible to store a configuration of a container in a file. Here achange was given. Old files are naturally compatible with the new container assistant. Thefiles generated with the new container assistants do not operate in all versions. It couldend abnormally if used in old container assistants.

Updating all presently loaded drawings

If several drawings have been loaded in designer and processed in active drawingCADISON-Objects, then all presently loaded drawings are updated. During this process,until now the docking tree dialog was updated a number of times (for each loadeddrawing). Since while updating drawing is not necessary, this process is not executed afterthis version.

Display of definition of configured labeling

The current setting of labeling is displayed in just one line in the dialog to configure labels(general labeling functions). In case of longer definitions, only the start of the definition isseen. After this version, the setting is displayed in multiple lines.

40

ITandFactory GmbH

CADISON R9.0.0 Release Notes

#20702Highlighting function from the docking tree and tables

If one of the Illumination-Functions is accessed from the docking tree and table and thedialog is not docked at present, then it is faded while highlighting the docking tree ortables so that the drawing of these dialogs is hidden.Thereby the docking dialog is faded, using which the Illumination-Function has beenaccessed.

#20898Data from / Data to

While selecting the objects in Designer, in case of both the functions a note "Selectobjects" appears.This is changed now:

o In case of function "Copy Data to" --> select target object o In case of function "Copy Data from" --> select source object.

#20693Property ATTEXCHANGE no longer dependent on case

Until now the feature ATTEXCHANGE is always entered in upper case and thus thematching attribute file was found. After this version it is no longer necessary.

Bug fixes

#22931Problem with setting the active field while working with XREF

If a drawing contains several XREF's and these drawings as well as the XREF filesassociated with it are loaded in the same designer-setting it could have problems underArchitectural Desktop 2009, if these drawings were active in different (e.g. in XREF-files ofmodel field, while the paper field is active in the main drawing).Partly, the processing of XERF files could lead to the fact that an incorrect field wasdisplayed by ADT 2009 as active in the main drawing.

#22607Duplication of connection points by using Copy&Paste

If in AutoCAD elements are copied and entered with Copy&Paste and thereby theassociated database elements are also copied, then while entering the graphics, it couldhappen that in case of some database objects the connection points are doubled. Thishappens in case of database objects which were additionally copied as sub-ordinatedobjects of the original objects selected graphically. After this version, the connectionpoints are no longer duplicated in case of these objects.

#22095Copying /renaming dialog after character test

41

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Start Designer and wait till it is automatically stored by AutoCAD.Subsequently access the drawing verification: The copy/rename dialog appears, whichshould be then broken with Task- manager so as to prevent further damage.

#21547No SLD files while creating symbol

1. If in symbol-editor a default object is generated and the new default object "Scale block1x1x1" is selected, then preview cannot be seen. *.sld-files are not created 2. If the selected graphic presentation (2D/3D/Symbol) does not match the drawingsetting, then preview is not created. *.sld-files are not generated

#22661Overwritten file as per "Save as"

When the current drawing has been copied with "Save as", it may happen that the originaldrawing in the database is set on "<<overwritten>>" and thus will not be available anymore. This error has been resolved in this version.

#22661Duplicate drawings as per "Save as"

If in the design, the current drawing is copied with "Save as", then it may happen that thedatabase creates two copies of the drawing and one of it is set on "<<overwritten>>".This error has been corrected.

#22769Elements are stored on incorrect layer

If a layer name is defined using the object model, then a corresponding layer isautomatically created in AutoCAD and used accordingly. If e.g. in case of a pipeline a layername is defined, then this layer name is used for the graphical pipeline elements.Thereby, until now it is not tested if the layer name has characters, which are not allowedto be used in AutoCAD. Thus till now the objects are stored in the incorrect layer.After this version, the layer name is checked for invalid characters (The characters are <> / \ " : ; ? * | , = '). If invalid characters are present, then these are replaced by aunderscore _ .

Note: The original name database is retained, the name will be adjusted at runtime,only within AutoCAD.

Double copy dialog while copying objects

If objects are copied in a drawing by graphical selection, then depending on the selectedobjects a CADISON copy dialog appears, where the database objects which are copiedmust be selected. In some rare cases it may happen that the copy dialog appears again,after the objects have been copied (or have been added again). This error has beenresolved.

#22527Abnormal end while designate objects

42

ITandFactory GmbH

CADISON R9.0.0 Release Notes

The control of some buttons was faulty in the "Object designation"-dialog. So it waspartially possible to use "Apply"-button, although "With labels" and "With leaders" wasselected. This could lead to abnormal ending of the Designer. After this version the buttonis available in case of respective option selection.

#22755"Create revision table" adjusts plot mode

In a layout multiple drawing revisions are created, then it may lead to change in thePlot-setting of the display window. Especially the option "Hidden" could thereby adjustedby the AutoCAD to "As displayed". This error has been resolved.

#22661Input of a file name in case of "Save as"

When the current file is saved with "Save as" in Designer then a dialog box appears forinput for new file name. Thereby it is checked whether the file name is already in use, asnew files names must be same within the project. Until now the test did not workcorrectly, a file name, which already exists in the project could have been given here.Thus the existing files are overwritten.

#22749Bent pipe cannot be labeled with block and leader

Until now a bent pipe could not be labeled with a block and leader since the layerdefinition for the leader is not available. After this version the layer for the leader isdefined.

#22240Updating the graphics while loading characters

While loading a drawing in the designer, it is tested if the graphics of drawings are stillactive. If not then these are updated automatically.Thereby there could be problems if the same drawing has been already loaded and loadedanew in the current designer setting. The graphics were not updated partially in thecorrect manner.

#22345Infinite loops after processing a block

If a block is directly processed in the current drawing in Designer using theAutoCAD-command REFEDIT and the current drawing or AutoCAD has been closed withouthaving to end REFEDIT-command, until now CADISON loaded in an infnite loop, since itwanted to save the drawing. However this dose not happen as long as theREFEDIT-command is active.After this version CADISON no longer runs in the infinite loops. The drawing cannot besaved. When the question "Save drawing" appears in AutoCAD, then it must be answeredwith "Yes", since at this point AutoCAD issues an error message and the close command isbroken. After that REFEDIT must be ended before AutoCAD is completed again.

#21955Graphic does not change as per "Copy Data from/Copy Data to"

43

ITandFactory GmbH

CADISON R9.0.0 Release Notes

When the data of one object with catalog entry is transferred to another with thecommands "Copy data from" or "Copy data to", then the graphic available on originalobjects is transfered to the target object. Thereby in case of target objects, a new defaultgraphic is activated.When the target object has already been placed in a drawing, then until now the graphicrepresentation of the target object is not updated automatically. This error has beenresolved.

#22365Maximum number of selection sets has exceeded

An AutoCAD selection list is used if while using CADISON explorer an option is selected ora different input point is reconverted with the space bar. This selection set was so far notreleased in existing CADISON. If the maximum number of available selection sets, i.e. 127has been achieved, then AutoCAD releases a corresponding error message in theAutoCAD-command line.after this version, the selection sets are released in correct manner so that the AutoCADmessage is no longer visible.

#22249Graphic presentation of objects in loaded drawings

If several drawings are loaded in Designer and if in one of the drawings changes are madein an object, which has an effect on graphics in other drawings, then these graphics areautomatically updated in other drawings.Until now, in some rare cases it could have happened that such graphic changes were notexecuted. This error has been resolved.

#21668Abnormal end incase of "Rotate object in line"

If the older CADISON explorer is activated in Designer and the command "Rotate object inline" is accessed then Designer ends abnormally. This error has been resolved.

#21599Change symbols in drawings as per Update in R8

In some cases it may happen in CADISON R8.x some symbols are replaced by othersymbols. This error has been resolved.

#21623Selection of a title block while plotting

While plotting CADISON searches for title blocks that contains the attributes RECEIVERand PRINTDATE. If a matching title block has been found, then these attributes areupdated automatically. If more than one matching title block is found, then the user mustselect one so as to end the plotting process.Thereby until now all layouts of the current drawing are analysed and not just the activelayout. If a different layout title block was available but not presently, then in spiet of thatCADISON asks for the title blocks which are to be updated. Since none were available inthe current layout, the user was not able to select any and thus the plot process could notbe ended. The Designer must be then ended in Task manager.

44

ITandFactory GmbH

CADISON R9.0.0 Release Notes

#22757Loading the AutoCAD-Architectural-Functions

So far if CADISON Designer was used based on the AutoCAD Architectural 2009, then notall Architectural commands are available, if the CADISON-Profile has been used. After thisversion, while using AutoCAD Architectural 2010, the Architectural commands areavailable even while using CADISON-Profile.

#23389Leader of the text screen labeling is not drawn in the selected form

Leader of the text screen labeling is always drawn with an arrow, eve though the user hadselected a different form (with full stop/slash/without).

Creation of modules

If modules are created in Designer, it may happen that the creation of these modules isinterrupted with a message that documents could not be read. If in existing versions,subsequent objects were added in the drawing, then these are not permanently stored inthe drawing. This error has been resolved after this version.

PDF-creation of DWG-files

The PDF-creation of DWG-files was not working till the path for DWG file or the DWGfilename had a point. This error has been resolved.

Route look up in drawing storage

Route search in drawing storage dialog does not work any more since CADISON R8.Always a message appears that no rout was found. This error has been resolved.

#21421Highlighting in layout

If one of the highlighted function is used in paper field of a layout, then it may happenthat after removing the highlight, the layout view has been destroyed and the layout mustbe restarted.After this version, while highlighting a layout, the previous view is no longer reset. If theview is changed in the layout while highlighting, then CADISON does not return to theprevious view after completing the highlighting.

Section creation in Russian AutoCAD-Version

The CADISON-section creation function does not work under Russian AutoCAD. This errorhas been resolved.

#21306Incorrect graphic presentation as per "Move object in piperun or line"

45

ITandFactory GmbH

CADISON R9.0.0 Release Notes

If in a 2D-drawing the Designer command "Move object in piperun or line" is used, then itmay happen in case of some objects that an incorrect graphic or too many attributes aredisplayed at the end of the command. Especially those symbols which used a graphicalreconversion of the attribute "Normally open/Normally closed" (RESTPOS).

#22127Change to the flow direction deletes database objects

If during connection the flow direction has been changed, then a new copy is internallycreated by the database objects associated with it and the original database object isdeleted.While deleting the original database objects, even the sub-ordinated components weredeleted, thus database objects could be deleted by changing the flow direction.After this version, the sub-ordinated components of the original database objects aretransferred to the copy, thus deleting of the original database objects does not delete thecomponents. These are automatically sub-ordniated to the new database object afterchanging the flow direction.

Updating Excel-Reports

So far there was the option "Create in background" in the dialog "Update report". If thisoption was selected for Excel-Reports, thus the excel-report file is destroyed.Nor can the creation or updating of Excel reports executed in the background, then thisoption is de-activated in "Update report"-dialog.

#21491, 22444, 22718Error message "Unsupported event" while staple plotting

Under AutoCAD 2009, a message saying "Unsupported event" may appear when the stapleplotting functions has been accessed. This message may appear after entering the nameof the recipient. The error message does not appear after this version.

#22964Incorrect result display in consistency test

During the consistency test the nominal diameter and nominal pressure are tested. Theresult table has two columns "DN" and PN". Thereby it may happen that one nominaldiameter has been displayed in "PN"-column. The result display was changed in such away that both (different) nominal diameters are displayed in the "DN" column if there areany different nominal diameters.

#21213Set measuring point in the display window/ section

So far, the setting of measuring points in a display window or while creating a sectiondisplay did not work in the Russian version of CADISON. This error has been resolved.

46

ITandFactory GmbH

CADISON R9.0.0 Release Notes

PID-Designer

Bug fixes

#22703color of the leader changes while copying the layout

The color of the leader changes when the layout is copied while labelling in layout.

#22761Drawing with MPL-lines shows errors on opening

While opening those drawings which have MPL lines, it may happen that a message"vcdb_MPL::dwgInFields Style ID NULL" appears, points that the used MPL-style is notavailable. Although the concerned MPL-lines were shown till now, but could not bedeleted. This status could lead to abnormal end of AutoCAD / the designer.After this version the concerned MPL-lines is reset to MPL-Style "Standard". With this theMPL lines can be correctly selected as per the loading process and processed further

#21586No flow direction arrow in case of MPL-pipelines

The flow direction arrow in case of MPL-pipelines, under some conditions is not displayedunder AutoCAD 2009. This error has been resolved.

#21854Error on connection on end caps

In CADISON R8.5, it is now not possible to place a connection on an automatically createdend cap.

#22089Graphic variants exchange with unsupported elements

The command "Exchange graphic representation" works only with AutoCADBlock-Elements (Insertion). If other graphics have been selected, (like e.g. Poly lines)then the command cannot exchange any graphics. Till now the command did not give anymessages when an invalid element was selected. After this version, a message is given atthe start that a block is to be selected and an appropriate error message is given when noblock is selected.

#23039Error in case of "Create visible pipe crossings"

If the command "Create visible pipe crossings" is executed and a pipe run (which isselected as constant pipeline) crosses a drive shaft then it is broken.Thereby the drive shaft loses the allocation to main object and subsequently remains"lose" in the database. In order to correctly execute "Create visible pipe crossings" withmechanical connection, signal line or working line, the attribute "Breakmode" has beenadded in the object model for the three classes "PHI-MCON", "PHI-SIGL" and "PHI-EFFL".

47

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Unicode sign within MPL style

The MPL module of CADISON was not able to handle Unicode signs correctly till now. Forone there were problems in dialogues for definition of MPL-styles, for some no MPL-stylecould be saved or loaded, Unicode signs which were present in the definition (e.g. Stylename or block name). These problems have been resolved in this version.

48

ITandFactory GmbH

CADISON R9.0.0 Release Notes

3D-Designer

Change of function

Segment curve

Segment curves have now been converted from VBA to MFC.

#23131Flanges and coils were not correctly exchanged while changing the nominaldiameter

In case of a pipe line the nominal diameter can be changed in a 3D drawing. For thispurpose the available elements are automatically exchanged by other elements usingMatpipe Selector. Until now flanges and coils were not exchanged correctly as these werenot entered in the FLT configuration files and thus mergeobject search was not possible inthe catalogs. The FLT-configuration files were enhanced for flanges and coils.

#22982Highlighting a 3D-drawing shows the drawing as a separate point

In some cases it may happen while highlighting 3D drawings that the limits of the objectsto be highlighted have not been determined correctly. Thereby, the drawing is zoomed outso much that it appears as a point. After this version the geometrical measurementscannot be determined from the 3D object, instead of that the input point of the 3D objectwas used.

#22819Counter in section names

A code letter has been determined by CADISON in the "Section"-Dialog for a section to becreated. Until now this code letter was increased on every access of the section function,even when the section-dialog has been ended with "Abort"-button. After this version, thesection letter is increased only when the dialog has been closed with "OK"-button.

#22522Extrusion while conversion into bent pipe

If an existing pipe line is made out of separate pipes and curves and extrusion has beenplaced there and this pipe line was then transformed in to a bent pipe, then the availableextrusions were deleted. After this version, the available sub-objects of the existing pipesand bents are transferred on the bent pipe so that other sub-components are not lostbecause a bent pipe is created.

Bug fixes

#22714, 21886ISOGEN Layout-Object and Start point -Object hampers centre allocation

49

ITandFactory GmbH

CADISON R9.0.0 Release Notes

If in case of a 3D pipe line ISOGEN layout- objects (like e.g. ISOGEN flow direction arrow)or ISOGEN start point has already been placed and subsequently the centre allocation isaccessed, then the center was not correctly allocated with pipes and curves. After thisversion, these ISOGEN objects were ignored by the centre allocation

#22762Bent pipe is created with remarkable geometry

The function for creating a bent pipe expects a specific sequence in case of connectionpoints. It is expected that a pipeline element is connected with connection point 2 withconnection point 1 of the next pipeline element. As soon as a pipeline element had beendrawn with a different flowdirection, this sequence was no longer given. From thisgeometry if a bent pipe was created, then this would have has an incorrect line flow.After this version, the creation of bent pipes is no longer dependent on a specificconnection sequence.

#22934Bent pipe with incline

Until now only the pipe lines could be transformed into bent pipe, if the pipe run had a 90degree bent. After this version even the bents can be used with different angles.

#22929Selection of read files in XREF-Manager

When a new file is to be allocated or super imposed in XREF-Manager, CADISONautomatically transfers the selected file, if it has already been read in the database. Untilnow the file was not transferred and no note appears.

#22097, 22717AutoCAD-Abnormal end while updating/ exporting 3D-Elements

In some cases it may happen that while updating a Matpipe 3D elements AutoCAD mayend abnormally with "Unhandled Access Violation"-Message. Likewise AutoCAD could endabnormally while exporting a drawing to NavisWorks or NavisWorks could abnormally enda DWG file if opened directly.For this the actuator can be 3D graphic which cannot be created (If e.g. The parametricfrom the matpipe cannot be built). Since the 3D-Graphic can be a basis for furtherauthorization (like e.g. Object start, Volumes calculation, etc.), till now it endedabnormally when a different CADISON function needed this information.

From this version CADISON no longer ends abnormally, but the required informationis not available (eg, the volume with "0" is calculated, or there are no object catches) are available..

#22602Abnormal end while labeling with block

When in a layout it is worked with the CADISON command "Designate objects with block"and positioning of the blocks of the caption is achieved under a viewport, then in rarecases, AutoCAD could end abnormally. This error has been resolved.

50

ITandFactory GmbH

CADISON R9.0.0 Release Notes

#22081Incorrect presentation of "New" primitives

If 3D graphic is built in a Matpipe, then with each one of the most primitive identifications,one of the codes "Unite", "Subtract" oder "New" can be used. So far, it could have lead todisplay errors while using the "New" option in AutoCAD, when an object was rotated, anda 3D display had been activated (eg, "3D Wireframe").Similarly, an incorrect graphic was made, if such a Matpipe element was initiated inAutoCAD with the command EXPLODE.

#23192Error while presentation and ACIS conversion of N-Edge MATPIPE-Primitive

Error while displaying and ACIS conversion of the N-Edge MATPIPE primitives. Especiallywhen the body is eccentrically extruded with holes.

#22980Matpipe-Elements are no longer displayed in 3D-Mode

In rare cases, it could happen that after opening a 3D drawing some 3D elements fromMatpipe are no longer displayed, as soon as a 3D display (eg, 3D wireframerepresentation) has been activated in AutoCAD. This error has been resolved.

#23220Abnormal end while pulling the pipes

When it is worked in AutoCAD with the command STRETCH and CADISON 3D pipes wereselected then it could lead to abnormal ending of AutoCAD depending on the set view.This error has been resolved.

#220863D-Display of wrongly parameterized Matpipe-Elements in Designer

In Matpipe, in case of graphic parametrization it can be specified for each primitive,whether a new primitive or a primitive to the previous primitive is to be added orsubtracted. It is possible to set the first primitive to subtract. From CADISON R8 suchMatpipe objects in CADISON designers in a 3D display are no longer displayed. After thisversion such Matpipe objects are displayed again, whereby naturally the first Subtraction-Primitives not displayed.

#21269Moving the element "Transition rectangular/round"

When a ventilation device of the type "Duct-Transition rectangular/round" was movedwith the CADISON Move command, the length of the object is changed. Likewise with theuse of CADISON command "Copy and rotate objects" would temporarily change the objectlength. After this version, the object length is no longer changed while moving andcopying.

51

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Electric-Designer

Bugfixes

Display of graphics in dialogue "Allocate measuring point typical"

The graphic of the selected typical is displayed in the dialogue. Till now this was active fortypicals, which were saved as .DEF-files. The graphic is displayed even for newly createdtypicals which were still not saved in .DEF-files.

Error message in case of invalid object selection

If in case of cable router, an invalid object is selected in the graphic, then till now perhapsan internal error message like "Zugriffsverletzung" [Access violation] or something similaris dispalyed. This error has been resolved.

Creation of HookUps

The function for automatic creation of HookUps among others cerates piece lists in thegraphic. The definition of piece lists was present in the fixed defined DWG-pattern. Afterthis version, it can be freely defined, as to which DWG-pattern is to be used for the pricelists.

VBA-Function "Batch processing of contact sets" replaced by C++ function

VBA-Macros for command "Batch processing of contact sets" are re-programmed in C++.

52

ITandFactory GmbH

CADISON R9.0.0 Release Notes

ISOGEN

Function changes

ISOGEN-License

After this version a license is required for isometric generation using ISOGEN. This iswritten off on accessing the isometric generation and released after ending the designer.

#21324Effect of MLD-entries for ISOGEN-piece lists

During isometric generation, similar objects are entered in the ISOGEN-piece list. Theobject feature ISOGEN-DESCRIPTION is used for consolidating similar objects. It ishowever, possible to release additional object features in the ISOGEN piece list, if the MLDfile is enhanced accordingly. While consolidating similar objects no entries from the MLDfile were considered till now. So it would happen that the objects in the piece list havebeen consolidated in the piece list although separate entries could have been created.Thus, after this version, the entries from MLD file is noted during object comparison.

#21295Additional MLD features for elements of a screw group

If in ISOGEN-Stil in .MLD-file, additional features are defined for the piece list, then tillnow these are not used for all elements of a screw group but only while moving the screwgroups. After this version the additional features for all elements (Screw, nut, and discs)are released.

Bug fixes

#21852Abnormal end of the MLD-Editor

Because of abnormal ending of the program, the working folder for ISOGEN MLD editor ischanged from (…\CADISON\App\Alias) to (…\CADISON\Config\VCS-IGEN) in CADISONR9.

#22522Extrusion on bent pipes in isometry

If extrusions are attached in a 3D drawing on a bent pipe and ismoetry is to be createdfrom the pipeline, the process breaks with ISOGEN-error message "Disconnected Pipeline".After this version, the extrusions can be released in the isometry, when the feature"ISOGEN component-identifier" is set to "OLET" during extrusion.

Creation und updating / revising of isometric drawings

While creating isometric drawings, all isometric pages (dxf-files) of pipeline created byISOGEN are imported and stored as layout in a Dwg-file, when the project has

53

ITandFactory GmbH

CADISON R9.0.0 Release Notes

"ISOGEN-PIPE-SINGLEDWG" attribute and it is set on "1(Ja/Yes)". Thereafter it is possiblefor the user to control the user interface if while creating the new isometr the currentisometry is just updated or revised automatically.

#21378Feedback of the ISOGEN position number as per CADISON

If in designer, a pipeline isometry is generated, then CADISON automatically creates aposition number for all positions. This number can be automatically imported in CADISON.This was not working till now when specific characters were present in pipeline names(Which were invalid for creating a file name). This error was resolved.

54

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Visio PID

Function changes

Performance optimizationConsiderable improvement in performance while moving multiple object at a time.

Working with multiple drawing at a time

Now it is possible to open multiple drawing in a single Visio instance and can work withthem by switching from one to another.

Next and previous button for the drawing switch

It is possible to switch to other drawings in current project through direct command.

Construction set

It is possible to create construction set for existing CADISON objects.

Undo

It is possible to undo the previous operations from drawing and also reflectd in database.

Exchange Graphic

It is possible to change the graphic representation of object placed in the drawing.

Copy paste across the drawing

It is possible to copy object/objects from one drawing to another along with databaseassociated with it across drawings which are open in single instance of Visio.

Configurable structure view

It is possible to configure the number of items in the structure view combo box in thecustom tree (This is applicable only to new tree dialog available only in Visio Designer).

55

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Pipeline color/Line type based in the mediaPipe line color and line type can be changed based on its superior media object.

Move object in pipeline

It is possible to move objects by maintaining its existing connections to other objects.

RGB color mapping, user defined line type and user defined flow directionsymbol

Now it is possible to map AutoCAD color to VISIO in the RGB format. Also AutoCAD linetype and Arrow symbol can be mapped with user defined line type and Arrow in VISIO.

.def file creation in Create new symbol command

One definition file will be created after creation of a new symbol from creates new symbolcommand which can be used to create.objects in other default databases.

Creation of user defined logical plantIt is possible to create logical plant with non-rectangular shape through assign graphiccommand.

Object Inspector

·         New better look of object inspector with vertical show hide button at tab level andalso this dialog is made dockable.

·         Changing the selection object in drawing will automatically update the contents ofObject Inspector.

Synchronize drawingWhile placing the object in the drawing, first object will attach to the mouse cursor andthen user will be able to place at desired location with left or right mouse button click.

Scale Object CommandCurrent scale of the object will be displayed in the scale dialog.

New separator in the Object Designation commandNew designation separator like "-", "." and new line are added in this command.

Design checker command doesn't hide objects consistentlyDesign checker was not hiding objects consistently. Sometimes object use to remainhidden after re-opening the drawing.

56

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Unable to open Help fileVisio online help was not getting invoked from certain dialog.

Unable to select multiple connection points for new symbolCreate new symbol was not allowing to select multiple symbolic connection points in onesymbol.

Continue pipeline dialog doesn't show correct pipe diameterContinue pipe line dialog was not displaying the correct diameter of selected pipe run.

Maintain shapes connectivity

It is possible to move objects by maintaining its existing connections to other objects.

57

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Project-Engineer

New functions

Adding of files and eMails per DragAndDrop

After this version, it is possible to add files from Windows explorer and emails fromMicrosoft Outlook through Drag and Drop in the opened project.

Function changes

#21133Selection of display configuration in case of active table separator

If the table separator is active in the main window of Engineer and until now a new displayconfiguration (via the"Select configuration ..." context menu has been selected in thetree, then the table has not been updated. After this version, the table is rebuilt accordingto the selected configuration. Thereby it is attempted to get the current position of thetable separator. If the new table does not have enough column, the previous position ofthe table divider cannot be restored, then the table separator is moved to extreme left.

#21154Display of write protected MEMO-features in the tables

If in older versions of CADISON (prior to release 8.5.0) MEMO feature has beendouble-clicked in the table, then it is was always reconverted to input mode. This wasdone for read protected-MEMO features, since with that by activating the input mode, thebutton for opening the MEMO editor was available. Therefore the complete text wasdisplayed even in case of write protected MEMO features. Changes were not saved in caseof write protected MEMO features.In version R8.5.0 it was no longer possible to reconvert in Engineer main window in theinput mode in the table. After this version, this functionality is available again.

#23368New system-error message

From this version, the new error message "Invalid parameter for CRT function" appears onscreen in the Project Engineer in case of internal errors. The same message is alsorecorded in CADISON.ERR. Previously, the Project Engineer would end abnormally becauseof these internal errors, after this release the error message appears. Subsequently, theProject Engineer is no longer stable and should be ended as soon as possible.

Renaming of documents without enhancing the file name

While renaming the documents, the new document name should always include a filenameenhancement. the following rules apply while changing the document name:

1. When a filename enhancement is specified, then this is used.

2. If name no name enhancement is entered for the new document, then the file name

58

ITandFactory GmbH

CADISON R9.0.0 Release Notes

enhancement is automatically taken over from the old names, provided it was available.

3. Renaming of documents without enhancement is no longer possible. A message thatthe filename enhancement has failed appears.

Bug fixes

#22822-22824, 22826Adjustments for AKH - multiple Windows

Diverse problems were resolved in the more window operation of Engineer within thescope of AKH specified version:

1. After starting the program, now 2 windows are opened in the AKH-version in thecorrect layout (30/70). The Tree in additional window is now sorted. Now in the leftwindow the structural view "not processed" is set.

2. 2 new windows are opened in the AKH version with the command "New Window".Now, only one window is opened correctly that one which lies exactly over theexisting window.

3. While closing one of these windows, an unsystematic part of the symbol list iseliminated. Now the symbol list is reduced only then when the last window isclosed.

4. Now the structural view a d the associated TOP5 lists are directly displayed andevaluated in AKH-Version after starting the program.

5. The name of the AKH specific TOE-Export-Function was changed to EDS-export incontext menu.

#22826Parts of symbol list dissapear while closing a window

If an existing window is closed at start, then a part of tool bar in the symbol listdisappears. The menu is completely visible only after restarting the Engineer.

#22468Abnormal end while updating the CADISON Tree

When F5 is pressed in Tree to updated CADISON-Tree, the Engineer ends abnormallywhen the project-object is visible in the tree outside the drawing.

#21667Login-Dialog appears while highlighting the object

If an object is edited in Engineer and highlighted, then it is required to login to CADISONwhile opening the Designer. This login window did not appear in 7th version.

#23332Changeover between windows changes the structured view

When several tree windows have been opened and a different structure view is selectedfor the current window using the "Structured view"-Dialog, then an incorrectly activestructure view is displayed in the selection list of the structure view after activating thetree window. This error has been resolved.

59

ITandFactory GmbH

CADISON R9.0.0 Release Notes

#21394Faulty menu and error toolbar after integration

If a project is opened in Engineer, which has a drop down and the project is integratedagain, then this project is deleted in the drop down. Thus by deleting the project the treewindow is automatically closed in Engineer. In the previous version however, the toolbarand menu is not updated so that then engineer ends abnormally while selecting a toolbarcommand or menu command.After the integration and deletion of the project, automatically the menu bar is removedafter closing the tree window and the tool bar is reset, so that a new project can bestarted from there.

#21337Changing the width of the last table column

In CADISON R8.5, it was partially not possible to change the column width of the lastcolumn in the table in main window. This error has been resolved.

#20954Ascending order of sorting in the last column

In R8.5 it was not possible to sort the last column in the table in ascending order in themain window of Engineers. This error has been resolved.

Activating the table section

If the table in main window of Engineer has already been scrolled towards right andsubsequently the heading lines of the tables are displayed on the context menu of tables,then until now the table heading was displayed on incorrect position. After this version,the table is compeletly scrolled to the left and only then the table heading is displayed.

Missing context menu for EDITABLEONETIME features in table

The context menu entry "Clear and unlock property" is not available on the table in themain window of the Engineers for the feature of type EDITABLEONETIME. This error hasbeen resolved.

#20978Help button refers to an incorrect path

There is a help button in engineers Dialog "Structured view->Modify Structured ViewDefinition...". The error message: "The file …\cadison.chm was not found" appears afterclicking the help button. This error message referes to an incorrect path. This error wasresolved in CADISON R9.

60

ITandFactory GmbH

CADISON R9.0.0 Release Notes

MATPIPE

New functions

Refernce to LINK-Objects in the formula

So far it was necessary to use the name of the Link object in order to relate to a feature ofsub-object in a formula (e.g. the term "LINK1.P_name" refers to the feature "P_name" ofthe sub-object, which has been defined under "LINK1").After this version it is also possible to relate to a special sub-object using the link positionnumber. For this purpose, the new keyword "POSx" is added, whereby "x" must bereplaced by the position number of the link object.For example, the term "POS2.P_name" refers to the feature "P_name" of the sub-objectwhose link has position number 2.

Copy Catalog

After release 9, the user can directly create a copy or a revision of Catalog in MATPIPE.This new command was implemented in the form of a context menu in the new Catalogselection dialogue box.

New opening dialogue box

In MATPIPE R9, the standard dialogue box to open the Catalog was replaced by a newone. The new dialogue box offers a better handling and overview of all available Catalogsand its content. The Catalog can be represented in a list or a tree format. The user canimmediately see which objects are found in the Catalog by clicking a Catalog in the list.Furthermore, additional information like the Catalog labelling and revision is alsodisplayed. Using the user rights, only those Catalogs can be displayed in this dialogue box, where theregistered user orders the respective rights.

#15629Update all dupilicate objects

Now, the duplicate objects of all available Catalogs or all selected Catalogs can be updatedin MATPIPE with one command. The new command can be accessed from MATPIPE menu"Extras-->Update Replica". Besides, the command can be executed from "Commandprompt", when the MATPIPE is started with parameter "UPDATEREPLICA" . Furtherinformation is available in MATPIPE Online help.

#16031Language neutral attributes

In addition to checkbox "Multi Lingual" one more option "Language Neutral" is available inthe dialogue box for attribute features. This option can be activate only then when "MultiLingual" has been selected.Activation of "Language Neutral" results in display of attribute names in MATPIPE tables asjust one single entry, e.g. "Material (Language neutral)" and not as "Material (german)","Material (english)" etc. as until now. This means that the labelling in all languages issame and it is handled accordingly in MATPIPE as well as in CADISON.Maintenance of data for language neutral attributes is not necessary in CADISON

61

ITandFactory GmbH

CADISON R9.0.0 Release Notes

dictionary.

Back-up of sub-folders

After release 9, MATPIPE finds those Catalogs which are found in the sub-folders withinthe Catalog path. Closed Catalog folders are not supported, i.e. if a Catalog is found in asub-folder then MATPIPE igonres all Catalogs under it, if some more Catalogs are found inthe folder or sub-folders present in it.

#19903 User login and user rights in MATPIPE

Now, after release 9, MATPIPE has access adminstration. Each CADISON user can beallowed or denied the access to Catalogs and functions in MATPIPE by the CADISONadministrator. Each user who starts MATPIPE must login yo the CADISON system. He canuse a function in MATPIPE or open a Catalog only after successful login. Thereby he can use only those functions and open those Catalogs for which he has authorisation.The access rights for MATPIPE are assigned in CADISON user adminstration.Following three rights for MATPIPE can be assigned to a user:

o MATPIPE Administratoro Change Catalog structure o Datamaintence

The authorisation can be idividually assigned to each user.

The search function MATPIPE and selector

After release 9, a new search function is available in Matpipe and also in selector in orderto quickly find Catalog objects. In Matpipe, the function can be accessed from the menupoint "Edit-->Catalog ObjectFind" and in selector using the button "Find object". Thesearch screen appears using this command. In the search screen, one can choose theobject type and filter, define as well as specify in what Catalog the object search is carriedout, for the desired feature. The result is displayed in a list. If an entry is selected in thelist, then the datalogue is opened directly and directed to the selected object in tree.

Export and Import of a Catalog

In MATPIPE R9, a MATPIPE Catalog can be exported with all files and then imported to thesame or a different computer. The new commands can be executed using the menu point"Catalog-->Export..." or "Catalog-->Import...". These functions are implementeddepending on the user rights in MATPIPE. If a catalouge in CADISON domains has beenassigned with specific users, then it cannot be used overall in the domain, if same usersare not available in other domains. The new export function removes all authorisationinformation from the Catalog and subsequently packs up all Catalog data in anunrestricted zipfile "*.mpex". This file "xxx.mpex", can be imported anytime with the helpof MATPIPE Import function.

#14977 Name and description for a configuration

While creating a configuration, it is possible to give a name and description for thisconfiguration in MATPIPE as well as in Selector.Here Matpipe / Selector automatically assigns a defualt text for configuration description.The current user name, date and time is entered by default. If a user does not want to

62

ITandFactory GmbH

CADISON R9.0.0 Release Notes

save this information then he must manually change this text.With the help of this process, additional information desired by most of the customers isreceived automatically without further user interaction (Creator and creation date).If it is reconverted to "Configuration" view in Matpipe or in Selector, then configurations ofthe same names appear in the tab "000-Favorites" of the detail table. If a configurationhas been selected, then a window appears which otherwise displays main entries anddescription of selected configuration. "Edit Configuration description" from the contextmenu can edit this data.

#20859Process and change configuration

After this version, if a configuration in the detail tabel is right clicked, thenMatpipe/Selector checks if this configuration has a sub-object "CONFIGOBJ". If anything isindeed available, then a new command "Edit configuration" is displayed in the contextmenu. On accessing this command a dialogue appears to change the data processor"CONFIGOBJ"-Objects, "CONFIGOBJ". If the dialogue has been ended with "OK" , then anew sub-entry is stored in the Catalog for "CONFIGOBJ". "CONFIGOBJ" uses the newsub-entry.

Updating configurations

After this version, the context menu in tree offers a new command "Update configuration"in Matpipe and in Selector. If an existing configuration has been selected in"Configuration"-tab and reconverted to "Catalog"-tab, then the selected configuration isdisplayed as active in green. The configuration can be changed there (e.g. select othersub-elements). New command "Update configuration" can be used from the existingconfiguration in order to complete the change so as to overwrite the existingconfiguration. However, a new configuration can be stored with "Save configuration".Note: In case of active CCC-functionality, a new time stamp is created by updatingconfiguration, in case of main object and the name of the last operator is updated. Thus,the CCC test in CADISON can determine that the configuration has been changed. Theconfiguration can be automatically updated there.

Functions changes

#20531coloring of configurable duplicate objects in Matpipe-tree

Duplicates in Matpipe tree are always shown in blue. If it deals with a configurable object,then it is displayed in red as a normal configurable object. Thus it was not clear that itdeals with a duplicate.After this version, the configurable duplicates are displayed in a different color. Likewise anew color is used in tree for the configured duplicates.

Enlarge input fields

The input fields in the dialogue box to create a new Catalog are enhanced. This change isexecuted in reference to the change in release 8.0, where the length of Catalog search hasbeen changed to 65 characters.

Login name in CCC

63

ITandFactory GmbH

CADISON R9.0.0 Release Notes

The name of registed user in MATPIPE/CADISON is taken over as the login name for CCCchanges. If MATPIPE is executed in stand alone mode, then the windows login name isused as before.

Improvisation of processing of Assembly rules

An entry must be made in the dialogue box for processing assembly rules by doubleclicking in the bottom field "moved" so that it can be edited. But it was deleted in the listabove and should have been added anew with "Insert" after changing and moved to theold place with "Up arrow"/ "Down arrow".Additional to the "Insert" button a new buttom "Change" implements which changes of theselected entry serves in the list.In order to simplfy the processing of entries in this list, along with "Insert" button,"Change" button is implemented in release 9, which serves the changes of the selectedentries in the list.Furthemore the size of the dialogue box can be changed now.

#20458Sorting of attributes in the main table

A sorting function is implemented in MATPIPE main table, which sorts the attributes withinthe tab. The sorting is in alphabetical order.

Retaining the object codes while changing links

In case of CCC functionality activated in Matpipe, all matpipe objects automatically get aunique code. Until now this code was reset, if it dealt with a configurable object inmatpipe, in this case a link was added or deleted. After this version, the object code wasretained with addition or deletion of links. Instead of that only the internal time stamp andname of the processor is updated.

Commands for storing configurations

The commands for storing configurations in tree context menu is now highlighted in grey,after this version, if the configurable obejct has still not been completely configured. Thisis same in Matpipe as well as selector.

Bug fixes

#22462Importing '999999999' from CSV-files

While importing CSV-files (not only in case of CSV import, even for neutral import), it mayhappen that the unit fields of value '99999999' has been saved as '1000000000' afterimporting. This error has been resolved.

#22180Display of links not selected during configurations

64

ITandFactory GmbH

CADISON R9.0.0 Release Notes

In the display tab for configurations, all features of the main object and those ofsub-objects (link-objects) are directly displayed in the detail table. When a sub-object isan optional sub-object and has not been selected for configuration, then the default valuefrom the feature definition appears in the detail table as value for this feature. After thisversion, the text "Link not configured" is displayed in the table.

Note: The text is displayed in red to cleary identify that it does not deal with regular text.In Matpipe red is used for showing errors, in this case however it does not deal witherrors.

#23311Cyrillic sign in parametric module

Until now Unicode signs like e.g. cyrillic signs were not used in the formula window inparametric module of Matpipe. These were partially displayed as question marks or theentire formula was considred invalid. After this version, even Unicode signs can be used informula input fields.

Duplication of duplicates

In Matpipe, it is possible to create new duplicates from the replaced data. Thereby, tillnow in target catalog, the references were partially created on the original cataloge,partially even on the catalog which has the first duplicate. After this version the entiredata of duplicates refers to original catalog.

Field ReplicaID_ is not filled in TGfxObject

When objects are duplicated in other catalogs, till now the field ReplicaID_ has not beenentered in the table TGfxObject. Normally, the record ID from the original catalog is to befound there.

#23231Transfer problem of graphic parameter while makeing object duplicates

In MATPIPE Release 8.6, there is a program error concerning the duplication of catalogobjects. I.e the graphic parameters are not transfered in the target catalog whiledupilcating the objects, if the name of source catalog was longer than 16 characters. Thiserror has been resolved in the current version.

Storing of configurations with CONFIGOBJ

When a configuration, which has an optional CONFIGOBJ, then a dialog appears where thethe data for CONFIGOBJ can be entered. If no data has been entered in this dialog thenan invalid configuration was stored till now, which was not able to be entered in CADISON.This errror has been resolved. After this version, storing such a configuration creates anew entry in the detail table of CONFiGOBJ-Object. This entry is uses the default valuefrom the object model. The configuration subsequently uses this new object.

Faulty error messages in parametric module

An error message is issued, when numerical value, which is outside the defined interval,has been entered in parametric module. Since R8, this error message could have signswhich cannot be read. This problem is resolved in this version.

65

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Problem with opening two catalogs

One catalog is open and attempt is made to open another catalog.If the second catalog cannot be opened, then following error occurs in the catalog view:Now only the catalog tree can be seen. The fields for object class lists, master or detail listview and the preview is highlighted in grey. This porblem can ne solved only by openingthe catalog again. This error was resolved in release 9.

#19720Sorting in MATPIPE Report generator

The MATPIPE Report generator was until now not in a position to correctly sort the texts,which comprises of alphabets and numbers. i.e. it was sorted just alphabetically. Thus theresult was that the text "DN20" was larger than text "DN100". This error is resolved inRelease 9.

#21175Updating problem in MATPIPE Tree

Updating had not properly workd while entering the data in a newly created catalog. Whena new section is created in new catalog or the features at the section level have beenprocessed, then the desiredpresentation for this level is updated only after closing the treeor after quiting the catalog. If, e.g. a new object was created, then it could happen thatthe symbols for already existing objects in tree have been replaced by Quader or cylinder.This error was resolved in the current version.

#21382Drag & Drop error in MATPIPE Tree

MATPIPE ends abnormally, when one has moved a specification object in an open catalogthrough Drag and drop on the top most source object. The error has been resolved.

# 21261Abnormal end of program

MATPIPE abnormally ends while accessing an object if a property has been defined in thisobject and whose name had a point. In MATPIPE R9, it is no longer possible to define aproperty name, which contains a point.

66

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Selector

New functions

Display of selected configuration

When a configuration is selected in selector and subsequently changed to tab "Catalog",then all modules of the selected configuration are displayed as configured. This meansthat all the configured links and the detailed table entries associated with it arehighlighted in green. The tree in selector can be redesigned by pressing F5 and thecoloring can be reversed.

Loading the current catalogue status

Till now it was not possible to get the current status of the catalogue in CADISON Selectorif in case the catalogue has been changed in the background. In CADISON R9 there is anadditional button "Reload catalogs". This command, like "Update index", also includes allcatalogues so that the internal "Selektor Cache" is emptied. Subsequently, the currentcatalogue status is loaded anew.

67

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Project-Navigator

Bugfixes

Enter catalouge object

The command "Insert object from catalogue" was till now available from the tool bar aswell as the menu. As the Project-Navigator permits only reading access, no action isexecuted during selecting the command. After this version, the command is deactivated inthe tool bar and also in the menu.

68

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Engineer2Web

New functions

Engineer2Web view of the DWG and DXF files

A new menu was added for displaying the DWG and DXF files.

Function changes

#21938Engineer2Web Timeout Problem

The Timeout for script manager consists of just 90 seconds.

Bugfixes

#21935Special character in dialogue "Über..."

In Engineer2Web Administrator Tool, the special character was displayed in the dialogue"Über...".

69

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Administration

General

New functions

Renaming the users

After this version, it is possible to rename the user in the CADISON- user adminstrationwithout compelling to transfer the new user in the existing project database.

#20993Change of GROUP.FLG files to Unicode-Systems

When the additional programs startalldbs, stopalldbs and emptylogfiles are used on thesystems, in case of which a Unicode -code page is active (like e.g. in case of Russianoperating system), then incorrect content of the GROUP.FLG-files is written with by theseprograms. After this version the GROUP.FLG-files are correctly changed.

Correctly restore GROUP.FLG

Till now it could have happen that the CADISON additional programs startalldbs,stopalldbs and emptylogfiles have changed the GROUP.FLG-files of the database and havenot been corrected till the end as after using these programs, a different content was to befound in the GROUP.FLG files. After this version, the original content was rewritten at theend in the GROUP.FLG-files.

Bug fixes

#21749Transferring the variable "PHI_CONFIGPATH" in correct sequence

Transferring the variables "PHI_CONFIGPATH" for determining LocalCfg path was notcorrectly executed by CADISON administration tool "Configmanager". These variablesshould be transferred from the section of the current domains. If unavailable, then fromthe section "PHi-CADISON"."Modules.ini".

#21749 Importing the variables PHI_CONFIGPATH

The CADISON Config-Manager had imported the variable "PHI_CONFIGPATH", in incorrectsequence from CADISON.INI.The access to these variables must be in the collowing sequence:Transferring the variables from the section of the domain, if unavailable, then from thesection PHi-CADISON.

#21331Abnormal end of the conversion tool in case of simultaneous conversion of

70

ITandFactory GmbH

CADISON R9.0.0 Release Notes

several databases

The database conversion program can convert several databases simultaneously. efollowing entry was not available in CADISON.INI:[PHi-CADISON]FAST_RELEASE_OBJECT_COUNT=0

After this version, it is no longer necessary to create this entry in CADISON.INI, beforeseveral databases are simultaneously converted with the conversion tool.

#21937Queries of the user

The CADISON API offers a function to to request the available user. Till now this functionreturns all use objects, which were available in the system database. Thereby it is nottested if found user has been actively allocated to a user adminstration. After this versionthose users are informed who belong to active user adminstration.

NOMAT is marked as INVALID by DEFREAD

The value "NOMAT" can be entered in the object model files in the columnCATALOG_LEVEL. Till now DEFREAD.EXE infoms this value as invaild. After this versionDEFREAD.EXE identifies it as valid value.

#20981Option "Convert databases" in program UpdateDbs

The option "Update only Object modell"in the database conversion program was notcorrectly placed while changing the size of a window. Besides the "Maximieren"[maximise]-button of the window was not available till now.

71

ITandFactory GmbH

CADISON R9.0.0 Release Notes

ITFTOOLS

New functions

#22607Correction of dupilcate connection points

While using the Copy&Paste function in AutoCAD, it may happen that in case of some dataobjects, the existing connection points may become double. These unnecessary connectionpoints are searched in database and deleted using this option. This option gives outcorresponding messages when unnecessary connections points were removed. In thiscase, the ITFTOOLS -XCLEAN tools must be used in order to ensure that the databasestructure is correct after removing the connection points.

ITF Dialog box

The ITF-Dialog box was renewed.

New option -RESOLVEDEADTRANSACTION [Log-file]

If during operating CADISON, project database is deleted, then in most of the cases it mayhappen that the so-called Dead-transactions are created. Through these dead-transactionsthe file logical.log always keeps getting bigger in the default-database, thus CADISONkeeps getting slower.These dead transactions can be resolved only when databases of same names are createdand the default database is restarted. Subsequently, databases created temporarily can bedeleted again.This option executes this setp automatically. -RESOLVEDEADTRANSACTIONS can only be executed directly on the server if no otherCADISON work stations have started a CADISON application.The parameter [Log-file] is optional. Here, the name of a file which is to be created can bespecified (including the path). The file is always created anew by this option and theessential specifications are retained.

New option -DELDBSINRB [Log-file]

Databases, which have been stored in so-called recycle bin-database groups can beautomatically deleted with this option. The option is executable only direct on the serverand no CADISON-applications must be active.iAny number of recycle bins can be defined using the entry in CADISON.INI, in section[PHi-CADISON]:[PHi-CADISON]RecycleBinFolder=1 recycle bin;recycle bin department 1;recycle bin department 2

If a database is not reqiured any more, then the CADISON user can move this in to therecycle bin without having to delete it immediatly.These databases are automatically deleted when the new ITFTOOLS-Option is accesse.Thereby it is ensured thatno dead transactions are created in the default database bydeleting a project database.The project folders associated with database are also deleted when the database isdeleted. Likewise the entries in CADISON-Tree are also deleted.The parameter [Log-file] is optional. The name of a log file can be given here (includingthe path). When a name is specified, then DELDBSINRB creates a new log file and recordsall the essential messages. An already existing log file is deleted.

72

ITandFactory GmbH

CADISON R9.0.0 Release Notes

New option -TRANSFERDOCS

After this version, ITFTOOLS offers a new undocumented option. With this option alldocuments of a project can be read or transferred in the database.The syntax of the option is:ITFTOOLS -TRANSFERDOCS <dbname> READITFTOOLS -TRANSFERDOCS <dbname> WRITE

The READ-sub-option reads all documents, the WRITE-sub-option transfers all documents.At the end of the process information containing the number of documents successfullyprocessed, how many had errors and how many were to be omitted based on these errors(e.g. "missing documents", which were not associated with the project).

Function changes

Correction of unused graphical representations

After this version, the correction function of ITFTOOLS (e.g. -xclean) can no longer identifyand delete referred graphical representation, which were not connected other objects fromthe CADISON tree.

73

ITandFactory GmbH

CADISON R9.0.0 Release Notes

API

Bug fixes

Setting of feature values using CADISON API

Till now, no new feature value in case of the object CDSNProperty was set with theCADISON API, if the feature was a unit field with one fixed selection list and a minimumand maximum value. This error is now resolved.

74

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Conclusive Information

The CADISON Hotline is available during the time mentioned below:

Mon. – Thurs. 08:30 bis 17:00 Uhr Fri. 08:30 bis 15:00 Uhr

Telephone: +49 6196 6092-500Fax: +49 6196 6092-202Email: [email protected]

In case of special questions you are welcome to contact our employees.

CADISON Training:

Training officeTelephone: +49 6196 6092-510Fax: +49 6196 6092-202Email: [email protected]

CADISON Sales:

Sales officeTelephone: +49 6196 6092-310Fax: +49 6196 6092-202Email: [email protected]

Further information can be found on our Internet homepage:

www.cadison.com

or contact us at

[email protected]

We wish you great success with CADISON.

Your CADISON-Team

75

ITandFactory GmbH

CADISON R9.0.0 Release Notes

Index

- 3 -3D-Designer 48

- A -ACIS-converter 32Actuator is on incorrect layer 39Allocation of measuring point 36API 73Archiever 33AUTO_DUCTSPEC 48AUTO_PIPESPEC 48, 39

- C -Calculation of the length of screws 48Conclusive information 74Consistency checker 39Consistency test 39Copy 60Cross references 21

- D -Designer general 39Drawings of new pipelines 39

- E -Electric-Designer 51Engineer2Web 68

- F -FILEREFERENCE 34

- G -General 21General 69Graphic entries 60

- I -Invalid characters 21Invalid graphical representations 21ISOGEN 52ISOGEN-module-code ffor screws 52ITFTOOLS 71ITF_DUCT 48

- K -Key word"hasTableOnly" 34

- L -Labeling dialog 39Links 60

76

ITandFactory GmbH

CADISON R9.0.0 Release Notes

- M -Manual counter 39MATPIPE 60MATPIPE 60Memo fields 21Moving of numbers 21

- N -N-Edge incorrectly presented 48

- O -Object locking while report generation 34Object model 36ObjectInspector 39Overview of bug fixes 14

- P -Parametrization dialog box 60Performance optimisation 21PID-Designer 46Project comprehensive copying 21Project-Navigator 67

- R -Reinstallation 4Report generator 34Report-Mappingdatei report.tpm 34Right “create object“ 34

- S -Selector 66Symbol editor 39

- U -Uninstallation 4Use of SelectionMarker '0' in 3D-Elements 48

- V -Ventilation channels 48Versant-Patch 2 21Versions stand of report documents 34Visio PID 54

- W -Windows Vista 39

- X -XREFS 39