Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached
to the main framing members using extruded aluminum "retainers" or "pressure plates". These
retainers are typically fastened to the main framing members with Torx fasteners, which are
sealed with a vinyl washer and located at a maximum spacing of 12" on center. EPDM glazing
gaskets separate the glass from the aluminum above and below. Retainers are then continuously
wet-sealed in the field with high performance silicone sealant and covered with a finished
aluminum "snap-on cap" extrusion to conceal the retainer fasteners.
At horizontal framing members, the glass is retained to the frame by using structural silicone
sealant joints between the glass edges and the crossrafter glass stop. This design creates a flush
joint that eliminates water damming and debris build-up. A slide-in PVC glass stop is standard at
this detail to reduce thermal transfer from exterior to interior. All crossrafter structural joints and
continuous pressure plate weather seal joints are married together to create a complete
water-tight installation.
WEATHER SEALANTSTRUCTURAL SEALANTGLASS STOPBACKER RODGLAZING STRIP
EXTR. ALUM. CAPEXTR. ALUM. RETAINER
GLAZING STRIPWEATHER SEALANT
EXTR. ALUM. CAPEXTR. ALUM. RETAINER
GLAZING STRIPFASTENERS
SPACER BLOCKWEATHER SEALANT
STRUCTURAL SEALANTBACKER RODGLASS STOPSETTING BLOCK
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
RAFTER CROSSBAR
ISOMETRIC
GLAZING STRIP
Super Sky Products' total flush glazing system (TFG) is based on silicone sealant technology and
uses unique continuous extruded aluminum retainers and intermittent hold-down clips for the
attachment of the glass to the frame. The retainers are adhered to the glass using structural
silicone sealant which is applied and cured in the glass fabricator's controlled factory environment.
There are no exterior fasteners or aluminum caps beyond the glass surface, thereby providing a
true thermal break system.
Each lite is independent of its adjacent lites, and can be replaced without removal of others. The
exterior weather seals are high performance silicone, which is applied after all lites have been
secured. The entire exterior surface of the glass is one flat plane with no obstructions to dam
water or cause dirt and debris build-up.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
14" MACHINE SCREW
EXTR. ALUM.RETAINER CLIP(SWIVEL)
WEATHER SEALANTSETTING BLOCK
GLASS STOP
EXTR. ALUM. FACTORYAPPLIED GLASSRETAINER CHANNEL
EXTR. ALUM.FIELD INSTALLEDRETAINER CLIP (SWIVEL)
EXTR. ALUM. RAFTER
EXTR. ALUM. CROSS RAFTER
RAFTER CROSSBAR
ISOMETRIC
SILL & HEADS assure proper perimeter interface with the adjacent construction, and are fitted with
formed sheet metal flashing to provide a water tight condition between the skylight and the
adjacent construction. Sill conditions are typically the low point for the skylight condensation
guttering system and allow for evacuation of any potential condensation collection through the use
of weep holes, which are shop located and drilled in the sill extrusion. Typically the weep holes are
located at each rafter.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
GLASSEXTR. ALUM. SILLEXTR. ALUM. SELF-FLASHING
SILL BASE
EXTR. ALUM. SILL
WEEP HOLE
WEATHER SEALANTFLASHING
VARIABLE SILL
VARIABLE SILL
CROSS RAFTER SILL
GLASSEXTR. ALUM. SILL
WEEP HOLEWEATHER SEALANTEXTR. ALUM. SILL BASE
EXTR. ALUM. CAP & RET.
EXTR. ALUM. TUBE
GLASS
SELF-FLASHING SILL
ZEE-CLIP, IF REQ'D,BY ENGINEERING
w/ INSULATED CLOSURE
FLASHING
GLASS STOPSTRUCTURAL SEALANT
SILL & HEADS assure proper perimeter interface with the adjacent construction, and are fitted
with formed sheet metal flashing to provide a water tight condition between the skylight and the
adjacent construction. Sill conditions are typically the low point for the skylight condensation
guttering system and allow for evacuation of any potential condensation collection through the use
of weep holes, which are shop located and drilled in the curb extrusion. Typically the weep holes
are located at each rafter.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
LOW-PROFILE FORMED SILL
SILL
GLASS
STRUCTURAL SEALANT
FORMED ALUM. SILL
EXTR. ALUM. ANGLE
SETTING BLOCK
WEATHER SEALANT
FLASHING
EXTR. ALUM. TUBE
ALUM. GLASS STOP
WEATHER SEALANT
FLASHING
E5
E5
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
HEAD
HEAD
FLASHING
WEATHER SEALANT
GLASS
EXTR. ALUM. TUBE
FLASHING
WEATHER SEALANT
GLASS
EXTR. ALUM. TUBE
EXTR. ALUM. RAFTER SUPPORT
WEATHER SEALANT
E5
E5
HEAD
FLASHING
GLASSEXTR. ALUM. TUBE
SEALANT
PRESSURE BAR
FASTENER
FLASHING
BATT INSULATION
SUPPORT & MOUNTING methods are used to connect Super Sky extrusions to supporting
structures when all aluminum structures may be impractical due to spanning length. Even with
accurate support structures, the ability to level, adjust and permit thermal movement is important.
Plate and fastener sizes are engineered for each particular project, based on project specific
loading requirements.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
RAFTER CROSS RAFTER
RAFTER CROSS RAFTER
ALUM. SUPPORT POST
EXTR. ALUM.RAFTER SUPPORT
ALUM. BASE PLATEANCHORS
FASTENER
STEEL FIN & C-CHANNELBY OTHERS
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
EXTR. ALUM. TUBE
RAFTER SUPPORT
RAFTER SUPPORT
THRU-BOLT
EXTR. ALUM. RAFTERSADDLE SUPPORT
ANCHORS
EXTR. ALUM. TUBE
THRU-BOLT
EXTR. ALUM. RAFTERSADDLE SUPPORT
ANCHORS
RIDGES & HIPS allow changes in the planes of the glass, often with single extruded
members. Structural analysis governs the sizes. The shapes are governed by the
skylight geometry and the angles of the intersecting rafters.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
RIDGE
HIP
EXTR. ALUM. HIPCAP & RETAINER
EXTR. ALUM. HIP TUBE
INTERNAL GUSSET PLATE
EXTR. ALUM. HIPCAP & RETAINER
EXTR. ALUM. HIP TUBE
EXPOSED TRUSSHEADFASTENERS
CONNECTIONS are as important as the size of spanning members to the skylight design. This
section shows methods employed to join multiple members together.
CLIPS, PLATES and FASTENERS are shown at standard configuration for detailing purposes, but
all connections will vary according to the specific design loads & resultant calculations.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
INTERNAL ANGLE &CHANNEL CLIPS
APEX (4 BARS) APEX (8 BARS)
CROWN
HIP/RAFTER
APEX (HIP END)
CROSS RAFTERRAFTER /
HIP / SILL
RAFTER / SILL
ANCHORBLOCK
ALUM.PIPE
INTERNAL ANGLE &CHANNEL CLIPS
FORMED ALUM.ANGLE CLIPS
GUTTERS have many possible forms and are primarily detailed at the base of a skylight to quickly
drain water to a discharge point. Eave gutters provide water and ice control at the transition from
sloped to vertical glass planes over doors and walkways. Gutters are also used at skylight
clusters with a built-in slope for quick discharge.
Gutters can be formed or extruded, and contain pitched sheet metal or neoprene liners, sloped to
scuppers or drain locations. Gutters are to be insulated to reduce formation of condensation on
the interior and provide support for the pitched liners. Gutter details can be directly related to
support details.
200RT2W/O
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
CANTILEVERED GUTTER
INTERIOR GUTTER
FORMED ALUM. GUTTER
FASTENERS
EXTR. ALUM. TUBE
STRUCTURAL SEALANT
EXTR. ALUM. SILL
GUTTER HIGH POINT
GUTTER LOW POINT
GUTTERS have many possible forms and are primarily detailed at the base of a skylight to quickly
drain water to a discharge point. Eave gutters provide water and ice control at the transition from
sloped to vertical glass planes over doors and walkways. Gutters are also used at skylight
clusters with a built-in slope for quick discharge.
Gutters can be formed or extruded, and contain pitched sheet metal or neoprene liners, sloped to
scuppers or drain locations. Gutters are to be insulated to reduce formation of condensation on
the interior and provide support for the pitched liners. Gutter details can be directly related to
support details.
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
GUTTER
GUTTER
EXTR. ALUM. TUBE
GRATING
EXTR. ALUM. ANGLE
FORMED ALUM. SUPPORT
FORMED GUTTER LINER
EXTR. ALUM. TUBE
ALUM. SUPPORT BRACKET
THERMAL EXPANSION provisions are typically included in each horizontal crossrafter, so that
thermal expansion is managed incrementally, not accumulated at one end. There are also
expansion joints in the sills and heads every 10 to 20 feet, to accommodate movement yet
maintain water-tightness.
There are some combinations of size, geometry, and supporting structure which may require
double members bridged by expansion materials. This condition will always occur when the
skylight frame intersects building expansion joints, and the frame needs to be separated to
accommodate movement of the building.
Seismic activity in some areas requires specific engineering, using sliding connections and
expansion type joints to avoid racking of the frame (not shown).
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
EXPANSION JOINT
EXTR. ALUM. TUBE
NEOPRENE
EXPANDABLEALUM. FLASHING
ALUM. CLIP
NEOPRENE FLASHING
EXTR. ALUM. TUBE
EXPANSION JOINTEND RAFTER w/
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
CONT. 14" ALUM. ANGLE
FABRICATED TEESUPPORT @ EA.RAFTER
CONT. 14" ALUM. ANGLE
FABRICATED TEESUPPORT @ EA.RAFTER
SNOW GUARD
STAINLESS STEELRETAINER PLATES
58" ST. STEEL TUBE
316" ALUM. TUBE
STAINLESS STEELRETAINER PLATES
38" SPLICE PIN
58" ST. STEEL TUBE
SNOW GUARD
EXTR. ALUM.RAFTER TUBE
ALUMINUMSUNSCREEN
SUNSCREEN
SNOW GUARDS
SUNSCREEN SHADES
G1
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
ALUM. FLASHING
EXTR. ALUM. TUBEVENTED RIDGE
CLEVIS & CABLE
EXTR. ALUM. TUBE
FORMED ALUM. PLATE
CABLE BRACING
CLEVIS & CABLE
FORMED ALUM. PLATE
EXTR. ALUM. TUBE
CABLE BRACING
VENTED RIDGES
CABLES
L2 - L
2 O
PP
.
350RT2
L2 - L
2 O
PP
.
350RT2
GS
1.2
*
GS
1.2
*L
2 - L2
OP
P.
350RT2
L2 - L
2 O
PP
.
350RT2
GS
1.2
*
GS
1.2
*
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
OPERABLE VENT
OPERABLE VENT
ALUM. VENT FRAME:FIXED SIDE
ALUM. VENT FRAME:OPERABLE SIDE
ALUM. VENT FRAME:FIXED SIDE
ALUM. VENT FRAME:OPERABLE SIDE
24V-DC LINEAR ACTUATORS
24V-DC LINEAR ACTUATORS
OPERABLE VENTS
10301 N. Enterprise Drive
Mequon, Wisconsin 53092
Phone: 262.242.2000
Fax: 262.242.7409
www.supersky.com
FLASHINGRETAINER(IF REQ'D)
TYPICAL SILLFLASHING
TYPICAL FLASHINGLAP JOINT(6" LAP & SEAL)
FLASHINGRETAINER(IF REQ'D)
WEATHER SEALANT
SILL FLASHING
BATTEN CLOSUREBY OTHERS
REGLET &COUNTERFLASHING
BY OTHERS
SASH FLASHING
ISOMETRIC
SECTION
FLASHINGAT STANDINGSEAM ROOFS
REGLETDETAILS
SAW CUT SURFACE MOUNT
GABLE END FLASHING
ISOMETRIC:GABLE END
ISOMETRIC:FLASHINGTRANSITION