2
quickstart guide DM-TX-200-C-2G-FLOOR/WALL www.crestron.com 888.273.7876 201.767.3400 Specifications subject to change without notice. DM-TX-200-C-2G-FLOOR/WALL QUICKSTART DOC. 7256B (2032217) 10.11 Floor Box/Wall Plate DigitalMedia 8G+™ Transmitter 200 Installation Overview Installation 1 3 1 For details, refer to the latest version of the DM-TX-200-C-2G-FLOOR/DM-TX-200-C-2G-WALL Operations and Installation Guide, Doc. 7255. DM-RMC-100-C Ground DM OUT 24 G 24V 0.7A POWER PACK PoDM Via Connection to DM Switcher (DM-TX-200-C-2G-FLOOR and DM-MD8X8 Shown) Connection to DM Receiver/Room Controller—External Power Pack Required (DM-TX-200-C-2G-FLOOR and DM-RMC-100-C Shown) When installing the DM-TX-200-C-2G-FLOOR into a floor box (not included) or the DM-TX-200-C-2G-WALL into an electrical box (not included), verify that the required wiring has been fed through the floor box/electrical box before connecting the rear panel of the device. DM 8G+™ Output Connection Connect the DM OUT port of the transmitter to the DM 8G+input of a DM ® switcher, receiver/room controller, or other DM device. If connecting to a DM switcher, connect the transmitter to the DM IN port of a DMC-C/DMC-C-DSP input card of the switcher. For DM 8G+wiring up to 330 feet (100 meters) between devices, use any of the following cables (sold separately): Crestron ® DM-CBL-8G DigitalMedia 8G™ cable Crestron DM-CBL DigitalMedia™ cable Crestron DM-CBL-D DigitalMedia D cable Generic CAT5e (or better) UTP or STP Power Connection If the transmitter is not to be powered using PoDM, connect the 2-pin terminal block to the included power pack. Ground Connection Connect the chassis ground lug to earth ground (building steel). NOTE: Shielded cable and connectors are recommended to safeguard against unpredictable environmental electrical noise which may impact performance at resolutions above 1080p. NOTE: Connecting the 24 VDC 2-pin terminal block is not required if the transmitter is to be powered using Power over DM (PoDM). Rear Panel Connections 2 The DM-TX-200-C-2G-FLOOR is designed for installation in a 6 inch (153 mm) floor box (not included) or in an open, ventilated area (for example, under a table). The DM-TX-200-C-2G-WALL is designed for installation in a 2-gang electrical box (not included) in an insulated wall, floor, or ceiling. DM-TX-200-C-2G-FLOOR (Rear Panel) DM-MD8X8 Ground DM OUT 24 G 24V 0.7A DM-TX-200-C-2G-FLOOR (Rear Panel) Refer to Section below for information about installing the DM-TX-200-C-2G-FLOOR in a floor box (not included). Refer to Section on the following page for information about installing the DM-TX-200-C-2G-WALL in an electrical box (not included). 3A 3B The DM-TX-200-C-2G-FLOOR fits in a 2-gang opening in a 6 inch (153 mm) floor box (not included). A minimum mounting depth of 2.5 inches (64 mm) is required. Using a Phillips head or straight blade screwdriver, attach the DM-TX-200-C-2G-FLOOR to an installed floor box using the four included #6-32 x 3/4 inch truss combo head screws (2009211). #6-32 X 3/4” Truss Combo Head Screws (4) (2009211) DM-TX-200-C-2G-FLOOR (6503983) Floor Box (Not Included) DM-TX-200-C-2G-FLOOR Installation into Floor Box DM-TX-200-C-2G-FLOOR Installation 3A

Quickstart Guide: DM-TX-200-C-2G-FLOOR/DM-TX-200-C …

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Quickstart Guide: DM-TX-200-C-2G-FLOOR/DM-TX-200-C …

qu

icksta

rt g

uid

e

DM-TX-200-C-2G-FLOOR/WALL

www.crestron.com 888.273.7876 201.767.3400Specifications subject to change without notice.

DM

-TX

-20

0-C

-2G

-FLO

OR

/WA

LL

QUICKSTART DOC. 7256B (2032217) 10.11

Floor Box/Wall Plate DigitalMedia 8G+™ Transmitter 200

Installation Overview Installation1 3

1 For details, refer to the latest version of the DM-TX-200-C-2G-FLOOR/DM-TX-200-C-2G-WALL Operations and Installation Guide, Doc. 7255.

DM-RMC-100-C

COM

HDMI OUT

GND

TXRXRTS

CTS

SGSS

1

2

IR

LAN

DM IN

RESET

SETUP

24 V

0.75A MAX

DM-RMC-100-C

DM ROOM CONTROLLER

Ground DMOUT

24 G

24V0.7A

POWERPACK

PoDM Via Connection to DM Switcher (DM-TX-200-C-2G-FLOOR and DM-MD8X8 Shown)

Connection to DM Receiver/Room Controller—External Power Pack Required (DM-TX-200-C-2G-FLOOR and DM-RMC-100-C Shown)

When installing the DM-TX-200-C-2G-FLOOR into a floor box (not included) or the DM-TX-200-C-2G-WALL into an electrical box (not included), verify that the required wiring has been fed through the floor box/electrical box before connecting the rear panel of the device.

DM 8G+™ Output ConnectionConnect the DM OUT port of the transmitter to the DM 8G+™ input of a DM® switcher, receiver/room controller, or other DM device. If connecting to a DM switcher, connect the transmitter to the DM IN port of a DMC-C/DMC-C-DSP input card of the switcher.

For DM 8G+™ wiring up to 330 feet (100 meters) between devices, use any of the following cables (sold separately):

● Crestron® DM-CBL-8G DigitalMedia 8G™ cable● Crestron DM-CBL DigitalMedia™ cable● Crestron DM-CBL-D DigitalMedia D cable● Generic CAT5e (or better) UTP or STP

Power Connection

If the transmitter is not to be powered using PoDM, connect the 2-pin terminal block to the included power pack.

Ground ConnectionConnect the chassis ground lug to earth ground (building steel).

NOTE: Shielded cable and connectors are recommended to safeguard against unpredictable environmental electrical noise which may impact performance at resolutions above 1080p.

NOTE: Connecting the 24 VDC 2-pin terminal block is not required if the transmitter is to be powered using Power over DM (PoDM).

Rear Panel Connections2

The DM-TX-200-C-2G-FLOOR is designed for installation in a 6 inch (153 mm) floor box (not included) or in an open, ventilated area (for example, under a table). The DM-TX-200-C-2G-WALL is designed for installation in a 2-gang electrical box (not included) in an insulated wall, floor, or ceiling.

DM-TX-200-C-2G-FLOOR (Rear Panel)

DM-MD8X8Ground DMOUT

24 G

24V0.7A

DM-TX-200-C-2G-FLOOR (Rear Panel) Refer to Section below for information about installing the DM-TX-200-C-2G-FLOOR in a floor box (not included). Refer to Section on the following page for information about installing the DM-TX-200-C-2G-WALL in an electrical box (not included).

3A

3B

The DM-TX-200-C-2G-FLOOR fits in a 2-gang opening in a 6 inch (153 mm) floor box (not included). A minimum mounting depth of 2.5 inches (64 mm) is required. Using a Phillips head or straight blade screwdriver, attach the DM-TX-200-C-2G-FLOOR to an installed floor box using the four included #6-32 x 3/4 inch truss combo head screws (2009211).

#6-32 X 3/4”Truss Combo

Head Screws (4)(2009211)

DM-TX-200-C-2G-FLOOR(6503983)

Floor Box(Not Included)

DM-TX-200-C-2G-FLOOR Installation into Floor Box

DM-TX-200-C-2G-FLOOR Installation3A

Page 2: Quickstart Guide: DM-TX-200-C-2G-FLOOR/DM-TX-200-C …

qu

icksta

rt g

uid

e

DM-TX-200-C-2G-FLOOR/WALL

www.crestron.com 888.273.7876 201.767.3400Specifications subject to change without notice.

DM

-TX

-20

0-C

-2G

-FLO

OR

/WA

LL

QUICKSTART DOC. 7256B (2032217) 10.11

Floor Box/Wall Plate DigitalMedia 8G+™ Transmitter 200

DM-TX-200-C-2G-WALL Installation

The DM-TX-200-C-2G-WALL installs in a 2-gang electrical box (not included) in an insulated wall, floor, or ceiling. A minimum mounting depth of 2.5 inches (64 mm) is required. To install the DM-TX-200-C-2G-WALL in an electrical box:

1. Using a Phillips head or straight blade screwdriver, attach the DM-TX-200-C-2G-WALL to the electrical box using the four included #6-32 x 3/4 inch truss combo head screws (2009211).

2. Attach the included black faceplate (2032185) or the included white faceplate (2032202) to the front panel of the DM-TX-200-C-2G-WALL.

3B

2 For details, refer to the latest version of the DM-TX-200-C-2G-FLOOR/DM-TX-200-C-2G-WALL Operations and Installation Guide, Doc. 7255.

IP Address Setup

Setup of the IP address of the DM-TX-200-C-2G-FLOOR/DM-TX-200-C-2G-WALL depends on the way the transmitter is configured within the DigitalMedia system:

● If the transmitter is connected to a receiver/room controller, the transmitter uses its own configuration settings. The transmitter ships with DHCP enabled; however, the default IP address can be assigned by holding down the SETUP button while the unit boots up. The default IP address is 192.168.1.239. The default IP address overwrites the current setting.

● If the transmitter is connected to a DM switcher, the transmitter is automatically configured by the switcher.

If manual configuration of the IP address of the transmitter is desired, use Crestron Toolbox™ to set the IP address.

5

Crestron, the Crestron logo, Crestron Toolbox, DigitalMedia, DigitalMedia 8G, DigitalMedia 8G+, DM, and DM 8G+ are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and other countries. HDMI and the HDMI logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others.© 2011 Crestron Electronics, Inc.

5

BLU-RAY

TMTM

PWR

AUDIOIN

USBHID

HDMI

HDMIIN

PC

PCIN

LAPTOP

Front Panel Connections (DM-TX-200-C-2G-FLOOR Shown)

RESET

SETUP

8G LINK

8G ACTV

Front Panel Faceplate,

Black (2032185)or

Front Panel Faceplate,

White (2032202)(Both Included)

#6-32 x 3/4”Truss Combo

Head Screws (4) (2009211)

DM-TX-200 -C-2G-WALL(6505711)

2-Gang Electrical Box(Not Included)

Front Panel Connections

Audio Input ConnectionUsing an unbalanced 3.5 mm TRS mini phone jack cable (not included), connect the AUDIO IN port to an unbalanced audio source.

HDMI® Input ConnectionUsing an HDMI® cable (not included), connect the HDMI IN port to the HDMI output port of an audio/video source.

PC Input ConnectionUsing a VGA cable (not included), connect the PC IN port to an RGB (VGA), component, S-video, or composite video source.

4

DM-TX-200-C-2G-WALL Installation into Electrical Box

DM-TX-200-C-2G-FLOOR (Front Panel)