1
Our Platform. Your Touch.
QuickStartCREW+CoDeSyS
1
Index
HMI IPC I/O SCADA
1. CREW
1.1. Configuration of protocol Modbus RTU Master 1 1.2. Adding a new project page 21.3. Creation of variables or Tags 31.4. Creation of a “Switch Button” and connection to a specified Tag 51.5. Objects events 7
2. CoDeSys
2.1. CoDeSys Settings 102.2. How to save a Project 16
3. From CoDeSys to CREW
3.1. Import files from CoDeSys 173.2. Import Tags 18
4. SoftPlc Operating Mode 20
Pag.
1 1.1. Configuration of protocol Modbus RTU Master
From Esaware Software CREW:
1. Create an HMI project and connect an Esaware product ( i.e. EW112AA ) to “Modbus RTU Master”:
1
EW112AC
2
1.2. Adding a new project page1
1. A new project page can be created and managed in a very easy way.
3
1.3. Creation of variables or Tags 1
1. 1A Tag list (Tags) can be created and managed in a very easy and intuitive way. Use the Tags manager to create a project Tag or variable list.
2. You can use different protocols, for example “RTU Master”.
4
1
3. Then select for each Tag the Modbus driver.
1.3 Creation of variables or Tags
5
1.4. Creation of a “Switch Button” and connection to a specified Tag1
1. Each object in the library can be easily dragged and dropped in the project page.
2. After selecting “Switch Button”, click on “ Property” and then on “Tag”. Select the button and it will appear in the below page.
6
1 1.4. Creation of a “Switch Button” and connection to a specified Tag
3. Choose from the list the variable to associate and click“Ok”.
7
1 1.5. Object events
1. 1. Both Scripts and Functions can be associated to each object present in the page.
2. Here a couple of examples of association of the functions “ShowPageNext” and “bitSet” to Switch Button.
8
1 1.5. Object events
1
2CoDeSyS
10
2 2.1. CoDeSys Settings
1. For the first time open the ARCHIVE PROJECT provided by ESA in order to install, if necessary, some CoDeSys libraries not installed yet.
11
2
2. Create STANDARD PROJECT.
2.1. CoDeSys Settings
12
2
3. “Tools” >> “ Install device” to add step by step all ESA libraries ( XML-files).
2.1. CoDeSys Settings
13
2
4. “Application” >> “Add Object” >> “SymbolConfiguration”.
5. “PLC_PRG” >> to define Project Tags.
2.1. CoDeSys Settings
14
2
6. In “Symbol configuration” build a project.
7. If there are ESA I/O (EW600), add “ESA I/O (PlugDevice)”.
2.1. CoDeSys Settings
15
2
8. Associate program Tags to I/O mapping.
9. Compile the project (F11).
10. Create boot application file.
2.1. CoDeSys Settings
16
2 2.2. How to save a Project
• NOTE 1: now we have at our disposal 3 CoDeSys files (.PROJECT/.APP/.XML), that can be imported in CREW PROJECT (SoftPlc) and downloaded in the panel.
11. Now we can test the correct communication between CoDeSys Software and ESA EW100AB-EW100AC SoftPlc.
12. ONLINE > LOGIN to download the application into EW100 SoftPlc.
• NOTE 2: Follow 2.7 and 2.8 if you are using a Esaware Panel EW100AC.
• NOTE 3: Follow 2.12 and 2.13 only for TEST. You can skip them and go to CREW section.
17
3 3.1. Import files from CoDeSys
• NOTE: To create a CREW project refer 1.1: the following steps are referred only to CoDeSys section in a CREW project.
1. After you have installed CREW and you have created a project with a EW100AB (SoftPlc) or a EW100AC (SoftPlc) panel, you can IMPORT files ( .PROJECT/.XML) from CoDeSys to CREW:
18
3 3.2. Import Tags
2. “Import Tags” allows to visualize tags created in CoDeSys project:
3. Now it is possible downloading CREW project in EW100 panel; After download-window you can visualize CoDeSys options:a) Shut down CoDeSys software and let CREW compile CoDeSys project.b) Download “boot application” of CoDeSys ( file “.APP”).
1
Now your CREW+CoDeSys SoftPlc projects can worktogether on EW100 panel
On EW100 panel it is possible setting different operatingmodes of your SoftPlc.
20
4 SoftPlc Operating Mode
RUN MODE
OFF MODE
21
4 SoftPlc Operating Mode
STOP MODE
SHOW MODE
ESA elettronica S.p.A. via Padre Masciadri 4/a22066 Mariano Comense (CO) -ItaliaTel. +39 031 757400Fax +39 031 751777
ESA Technology, Inc. 320 Tesconi Circle, Suite JSanta Rosa CA 95401 – U.S.A. Tel. +1 707 5447300Fax +1 707 5447360
ESA Elettronica GmbH Carl-Zeiss-Strasse, 3563322 Rödermark - DeutschlandTel. +49 6074 486 45 0Fax +49 6074 486 45 66
ESA Software & Automation India Pvt. LtdB.R. House, 3RD Floor Hennur Main Road, Bangalore 560 043 - IndiaTel. +91 80 25435656Fax +91 80 25435658
ESAElektronik Technology Ticaret Limited Şirketi Şerifali Mah., Çetin Cad. Kıble Sk.No: 6 Of Plaza Kat: 5 D.: 7Ümraniye/İstanbul - TürkiyeTel.: +90 216 466 70 33Fax: +90 216 466 70 99
ESA Europa S.L.U. Passeig del Ferrocarril, 33508860 Castelldefels (Barcelona) - EspañaTel. +34 936455014Fax +34 936455013
意萨萨子科技(上海)有限公司中萨上海市宜山路889萨萨萨工萨城4萨萨6萨D1ESA Electronic Technology (Shanghai) Co. LtdUnit D1, 6F, Bldg. 4#, No. 889 Yishan RoadShanghai 200233 - P.R.ChinaTel. +86 21 6090 7250Fax +86 21 6090 7258
ESA energy S.r.l.Via Fortunato Zeni 838068 Rovereto (TN) - ItaliaTel. +39 0464 443272Fax +39 0464 443273