Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it
Quick user guide to Sevio – Elco Elettronica
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 2
© 2017 Sevio. All rights reserved.
Trademarks
Sevio is a Sevio S.r.l. trademark. Top7 is a Elco Elettronica registered brand. Other product names and
brands are registered brands or trademarks of their respective owners.
Declaration of terms
In the interest of improving internal design and operational aspects, Sevio S.r.l. reserves the right to make
changes to the products described herein without any prior warning.
Sevio S.r.l. disclaimes any liability for the application of the products or circuit diagrams described herein.
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 3
Preface
Industrial production demands in the era of globalization or delocalization are becoming increasingly more
complex. Within this context, creating a network of systems, processes and information is critical in order
to ensure success in a perpetually competitive environment and guarantee a continuous presence. Thus,
the possibility to remotely manage a production system becomes a keystone allowing reduced processing
times and costs, subsequently increasing and enhancing the performance of your business. Our objective
is to offer a system that complements existing computer technology, offering Clients simple, efficient and
secure control solutions.
The aims of the Sevio system are:
to offer Clients a private, affordable and continuously available network;
to relieve Clients of the need to perform complex configurations and subsequent maintenance;
to guarantee the highest standards of security;
to offer an efficient and timely system during all stages of a project's development.
The Sevio solution does not require the installation of any particular software or supplementary hardware.
Through the Sevio Portal, a Web application accessible from https://sevio.it/, parameters can be edited
remotely, system statuses can be viewed, and much more still.
So at this point, happy working!
Sevio S.r.l.
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 4
The Sevio system has been designed to offer Clients a solution for the connection of multiple independent
and physically dislocated networks, transforming them into numerous Sevio networks. Each Client is the
owner of a Realm which is the set of all Sevio networks and Control Stations (PC, tablet, smartphone).
This document explains how to use the Sevio system combined with Elco Elettronica products.
Index
Requirements ................................................................................................................................................... 5
1 Use of Sevio system ............................................................................................................................. 6
2 Sevio and Elco Elettronica ................................................................................................................... 7
2.1 Preliminary configuration ............................................................................................................... 8
2.2 Remote access through New TightVNC ..................................................................................... 10
3 Declaration of conformity and warranty ........................................................................................... 11
For Sevio system functions and characteristics refer to the Sevio User Guide.
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 5
Requirements
The fundamental requirements for use of the Sevio system with Elco Elettronica products are:
the Sevio Router;
the Registration Sheet document (supplied in the Sevio Router packaging);
an Elco Elettronica PLC with Ethernet connectivity;
a PC with an up-to-date web browser and Elco Elettronica applications installed;
an Internet access.
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 6
1 Use of Sevio system
Each Sevio Router is distinguished by a specific Sevio network. In the example above, the Sevio network
of plant A is 10.254.12.x, while the Sevio network of plant B is 10.128.71.x.
To access the PLC of plant A from the Control Station, it’s sufficient to combine the first three bytes of the
specific Sevio network with the fourth byte of the PLC address:
Control Station
10.254.12.30
Plant A
IP: 192.168.1.30
IP: 192.168.1.31
IP: 192.168.1.1
Sevio Network
10.254.12.x
Plant B
IP: 192.168.1.30
IP: 192.168.1.31
IP: 192.168.1.1
Sevio Network
10.128.71.x
Sevio Network plant A…...….
virtual:
PLC address plant A…...….
Remote PLC address plant A…...….
10 . 254 . 12 . x
10 . 254 . 12 . 30
192 . 168 . 1 . 30
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 7
2 Sevio and Elco Elettronica
The Sevio system allows Control Stations to communicate with all devices connected to the various Sevio
Routers.
Another exclusive feature of the Sevio system is routing, or rather the possibility for communication
between devices connected to different Sevio networks, yet forming part of the same Realm.
To use the routing feature, it is required to configure the Sevio Router as the default Gateway IP address
into all the network devices that communicate with each other.
Plant A
IP: 192.168.0.104 IP: 192.168.0.1
Sevio Network
10.254.12.x
Plant B
IP: 192.168.1.83
IP: 192.168.1.1
Sevio Network
10.128.71.x
Realm
IP LAN….192.168.0.1
IP Address..……192.168.0.104
Subnet Mask….. 255.255.255.0
Gateway………..192.168.0.1
IP Address..……192.168.0.105
Subnet Mask….. 255.255.255.0
Gateway………..192.168.0.1
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 8
2.1 Preliminary configuration
The procedure below describes the preliminary configuration of devices that need to be accessible
remotely.
A Sevio Router is sometimes installed in existing systems by personnel that is not qualified to modify the
software configuration. Using the Masquerade mode (see chapter Sevio Router Parameters in Sevio User
Guide) it is possible to access devices remotely omitting the procedure below.
NOTE: that enabling masquerade mode prevents the PLC/HMI device from originating connections to the Sevio Network.
Start TOP7 then press on progress bar to access to network setup.
Digit Password, then press ENTER to confirm.
Then tap the OK button to confirm.
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 9
Select Test IO button.
Select Network from Resources menu.
Identify the IP address, which in the example is 192.168.0.114.
Go to the Sevio Router parameters through the Sevio Portal and assign a /24 IP LAN address (see chapter Sevio Router Parameters in Sevio User Guide).
Insert the Sevio Router LAN address in the Gateway field, which in the example is 192.168.0.1
Press Yes to confirm.
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 10
2.2 Remote access through New TightVNC
Start New TightVNC and digit remote IP address in Remote Host field:
Then press Connect.
From this moment on, it is possible to perform all activities online.
Virtual IP:………….
Local PLC:………..
Remote PLC:..…….
10 . 255 . 254 . x
10 . 255 . 254 . 114
192 . 168 . 0 . 114
Document ID: sv_elco_elettronica_en_v17_05
https://sevio.it 11
3 Declaration of conformity and warranty
Sevio S.r.l. declares that the Sevio Basic device is compliant with the essential requirements and all
relevant provisions of Directive 1999/5/EC.
Sevio S.r.l. declares that the Sevio One device is compliant with the essential requirements and all
relevant provisions of Directive 2014/30/EU.
Extended Declarations of Conformity may be requested by contacting [email protected].
Every request for replacement under warranty must be sent before the expiry of the 2-year warranty and
must be transmitted together with the product that has allegedly presented an anomaly.
SEVIO
Sevio S.r.l.
Via Dei Caniana, 6/a – Bergamo (IT)
Tel. (+39) 035 0514333
Email customer assistance: [email protected]
Email sales department: [email protected]
https://sevio.it