[email protected] • 425-584-7206 nu-bird.com ©2016 Nu-Bird Inc. All rights reserved. Nu-Bird Suction Mirror is a registered trademark of Nu-Bird Inc. 1. Plug adapter into the HVE. Loop hose as shown using the Ergo Clip attach to the top of the curved metal tube. Point curved metal tube and hose end towards patient’s head. Insert the Nu-Bird suction mirror into the hose end until it clicks in and freely rotates with out falling out. 2. Prep mirror with medium grit Prophy paste. Select proper Insert, adjust power and water to appropriate settings. 3. Assess patient for hypersensitivity/gingival sensitivity and treat prior to procedure. 4. Turn on HV suction and practice retraction of the cheek and tongue moving about to develop a saliva coating on the mirror Face. Have patient to close on mirror saying, “Close on this like a spoon,” to remove excess residual water 5. INDIRECT VISION can now be used. • Start on the distals of the maxillary molars and slowly work toward the anterior of the mouth. • Keep the mirror face “wet” with ultrasonic spray occasionally “dipping” the mirror back against the tongue to the sides and back of the oral cavity to manage any excess pooling water. Additional details located in the User Guide section QUICK START UP GUIDE

QUICK START UP GUIDE · Mucosa. Place suction mirror distal lingual to Lower 2nd molar to retract tongue and manage pooling water and saliva. STEP 2 Place etchant on occlusal surface

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • [email protected] • 425-584-7206nu-bird.com©2016 Nu-Bird Inc. All rights reserved. Nu-Bird Suction Mirror is a registered trademark of Nu-Bird Inc.

    1. Plug adapter into the HVE. Loop hose as shown using the Ergo Clip attach to the top of the curved metal tube. Point curved metal tube and hose end towards patient’s head. Insert the Nu-Bird suction mirror into the hose end until it clicks in and freely rotates with out falling out.

    2. Prep mirror with medium grit Prophy paste. Select proper Insert, adjust power and water to appropriate settings.

    3. Assess patient for hypersensitivity/gingival sensitivity and treat prior to procedure.

    4. Turn on HV suction and practice retraction of the cheek and tongue moving about to develop a saliva coating on the mirror Face. Have patient to close on mirror saying, “Close on this like a spoon,” to remove excess residual water

    5. INDIRECT VISION can now be used.

    • Start on the distals of the maxillary molars and slowly work toward the anterior of the mouth.

    • Keep the mirror face “wet” with ultrasonic spray occasionally “dipping” the mirror back against the tongue to the sides and back of the oral cavity to manage any excess pooling water.

    Additional details located in the User Guide section

    QUICK START UP GUIDE

  • [email protected] • 425-584-7206nu-bird.com©2016 Nu-Bird Inc. All rights reserved. Nu-Bird Suction Mirror is a registered trademark of Nu-Bird Inc.

    STEP 1Place Dry Angle on Buccal Mucosa. Place suction mirror distal lingual to Lower 2nd molar to retract tongue and manage pooling water and saliva.

    STEP 2 Place etchant on occlusal surface for 30 seconds. Use Suction mirror for retraction and HV suction to manage water/saliva.

    STEP 3Rinse thoroughly with air/water spray, Keeping mirror stationary, retracting the tongue and... DO NOT DRY TEETH YET

    STEP 4Carefully slide cotton roll under tongue and move suction mirror over to rest on top of cotton roll, keeping the water/saliva away from tooth.

    STEP 5Now carefully dry teeth with air blowing water toward the face of the suction mirror and dry until tooth surface appears chalky or etched.

    STEP 6Place Sealant. Keep the suction mirror in a continued stationary position retracting the tongue and suctioning water/saliva away from teeth

    STEP 7Light cure for 20-30 seconds

    Dental sealants are easily completed in minutes without compromising quality and integrity or the need of an assistant.

    SEALANT PLACEMENT