802263UK - Residential Chilled - Quick start guide - Sept 2016 - V2.03
Quick Start Guide
• Before proceeding, read the Installation instructions and User guide.• Check all the components are present and correct.• Check that you have all the necessary tools.• Ensure the under-counter cupboard floor can support the product weight when full of
water,(check the specifications in the Installation instructions and allow an extra 2kg when full of water).
Note This Quick start guide must be read in conjunction with the Installation instructions and User guide.
Prior to installation, ensure that the following have been provided at the installation site.
• Sufficient space in the cupboard to install the Command-CentreTM and it’s ancillary components. Refer to the Technical specification of the Installation instructions for dimensions.
• A potable water supply connection with min / max working pressures of: (refer to the Technical specification of the Installation instructions for specific model information).
• An isolating valve inside the cupboard within reach of the flexible braided hose and positioned so that the connection point and the stop cock will not be obstructed when the Command-CentreTM and it’s ancillary components are installed.
• For Zip HydroTap®G4, a single 220-240V AC, 13A socket is required. • The Command-CentreTM must be installed in accordance with IEE regulations. See
Technical specification, page 9 Installation instructions for power ratings.
Note Check the cable lengths and outlet positions before proceeding and ensure that the tap location will allow the tap spout to drain into the sink. • The Command-CentreTM must be mounted in an upright position, with its base
mounted horizontally.
IMPORTANT! Do not proceed with the installation if these requirements are not met.
* Tap options supplied are dependant upon configuration purchased.
Step 1- Prepare and install the taps.
HydroTap®G4 Classic & Elite tap installation
All thread rod
Stainless steel
washer
Spider clamp
6mm nut
Black plastic spacer
Note Feed each of the tubes and USB cable evenly in between the legs of the spider clamp during installation.
Fit the stainless steel washer, spider
clamp, and 6mm nut.
6mm nut
Spider clamp
Stainless steel washer
Black plastic spacerØ35mm hole
HydroTap®G4 & Elite taps cut a 35mm hole in the worktop / sink.
Cut a Ø35mm hole in the worktop / sink.Ø35mmApply a light smearing
of silicon sealant on the underside of the spacer to ensure a watertight fit.
Example Classic HydroTap® installation
Hole positioning Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory. (See Major components and accessories, Installation instructions).
HydroTap®G4 Arc / Cube tap installation
The HydroTap Arc / Cube has a spout that may be fixed in one of 6 angular positions (depending on the position of the rotary control) and fixed in one of two height positions. The spout is fixed and does not swivel.
Configuring the tap
• Remove the 2 x spout locating screws and lower the spout to expose the plastic spring clip.
Note The plastic spring clip has two internal dimples that may be positioned in the 6 upper or 6 lower, pre drilled holes in the spout (see diagram below).• To reposition the spout, gently
spread the plastic spring clip to release the dimples from the spout
holes. When released, slide the clip on the spout so that it ends up between the two rows of holes.• Rotate the plastic clip on the spout
to orient the dimples, so they are in line with the newly selected holes.
Note When determining which of the 6 holes are required for the new spout height and orientation, check the new plastic clip position will clear the undercut and that the USB lead will not be pinched,when assembled.• Slide the plastic clip up/down to
engage with the selected holes, making sure the two dimples engage simultaneously with the two selected holes.
Note The clip will not fit correctly if one dimple engages before the other.
Both dimples must engage at the same time.• With the clip fitted to the newly selected holes,carefully raise the spout (ensure the USB lead is a neat fit in the
undercut and is located between the open ends of the clip) until the clip locating holes are in line with the spout locating screws.
• Replace the 2 x locating screws.• If mounting on an uneven surface, apply a light smearing of silicon sealant on the
o-rings to ensure a watertight fit.• Pass the assembly (ensuring upper o-ring, base ring and lower o-ring are in place)
through the Ø35mm hole and position the tap so it discharges into the sink.
• Fit the lower rubber seal to the threaded extension.
• Secure the tap in position with the metal washer and nut.
Dimples
Plastic spring clip
Spout locatingscrews (2)
Undercutfor loom
Lower locating positions
Plastic spring clip
Upper locating positions
Clip locating holes (2)
Upper o-ringBase Ring
Lower o-ring (above worktop / sink)
Lower rubber washerMetal washer
Nut (below worktop / sink)
Cut a Ø35mm hole in the worktop / sink.
NoteMake sure the tap location will allow the tap spout to drain into the sink.
Ø35mm
Parts supplied Description Parts supplied Description
1 x HydroTap®G4* Classic, Elite or #Arc / Cube#(inc. Tube kit)
1 x User guide and 1 x Quick start guide
1 x Installation instruction
1 xCommand-
CentreTM with air and water filters
1 x Mains water connection hose
Duct kit1 x Outlet vent1 x Inlet vent
1 x Installation fittings (supplied
with Celsius taps)
801599 - HydroTap User Guide - Nov 2013 UK - V1.05 Page 1 of 20
ZIP HydroTapUser Guide
®
• Tap Operation...................(Pages 2-5)• LCD Screen & Menu .......(Pages 6-18)• Maintenance.................... (Pages 18-20)• Date of Installation.........
Affix Model Number Label Here
801599
BC160/125G4BC240/175G4BCH160/125G4BCH240/175G4AV160/125G4AN160/125G4AV240/175G4AN240/175G4
801600 - Zip Quick Start Guide - October 2013 - V1.06
Parts Supplied Description Parts Supplied Description
1 offHydrotap Tap
and hoses
Duct kit1x Air Duct
1 x Mounting plate
1 offUndersink Unit
with air and water-filter
Vent kit
1 x Kickboard louvre
1 x Door vent louvre
1 x front vent grill
1 x Restrictaflow valve and Tee piece for Mixer
Taps
1 offHydroTap
Booster heater and hoses
(Supplied with 240/175 models)
1 off Mains water connection hose
QUICK START GUIDENote: This quick start guide must be read in conjunction with the main installation and user instructions • Before proceeding, read the installation and user instructions• Check all the components are present and correct.• Check that you have all the necessary tools• Ensure the underbench can support the product weight when full of water,
(Check the specifications in the main book and allow an extra 5-8kg when full. )
Before installing ensure the following have been provided at the installation site:• Sufficient space in the cupboard to install all of the undersink units in accordance
with these Installation Instructions. Refer to technical specification for dimensions. If required, make allowance for a booster heater. (Refer to the main book, for detailed installation instructions).
• A potable water supply connection with isolating valve inside the cupboard within reach of the flexible braided hose and positioned so that the connection point and the stop cock will not be obstructed when all the undersink units are installed.
• For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be required. (One GPO is for the Zip HydroTap and the other for the Booster heater). NOTE: Check the cable lengths and outlet positions before proceeding.
• A potable cold water supply with a minimum working pressure of 172kPa and a maximum working pressure of 700kPa connected via an isolation valve.
• For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.• The undersink appliances must be mounted in upright positions as shown in the
diagrams.
IMPORTANT! Do not proceed with the installation if these requirements are not met.
STEP 1- Prepare and fit the Taps
Hole positioning: Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, avail-able as an accessory.
Apply a light smearing of silicon sealant on the underside of the upper spacer to ensure a watertight fi t.
For HydroTap and Mixer taps cut a 35mm hole in the bench / sink top.
BENCH TOP
Ø35mm
HydroTap Tap
Mixer Tap 4-in-1 (If required)
NUT
LOWER RUBBER WASHER
UPPER RUBBER WASHER
WASHER
BRAIDED HOSE x 3
UPPER RUB-BER WASHER
LOWER RUB-BER WASHER
WASHER
NUT
White HoseExt. Mains
Blue bandMixer IN
Red bandMixer Out
O-RING
BASE BLOCK SPIDER
BASE BLOCK NUT
USB CABLE
ALL THREAD ROD
NOTE: feed each of the tubes and elec-trical cable evenly in between the legs of the BASE BLOCK SPIDER.
All-In-One Tap (If required)For AIO mains and vented TapsCut a 50mm hole in the bench / sink top.
NOTE: make sure the tap location will allow the nozzle to drain into the sink.
SINK TOP
50mmALL THREAD
ROD
STAINLESS STEEL
WASHER
SPIDER CLAMP
NUT
BLACK PLASTIC SPACER
NOTE: feed each of the three tubes and electrical cable evenly in between the legs of the SPIDER CLAMP when installing.
Fit the STAINLESS STEEL WASHER, SPIDER CLAMP, AND 6mm NUT.
6mm NUT
SPIDER CLAMP
Stainless washer
Black plastic spacer
35mm dia hole
SinkO-RING
SINK TOP
Fit the O-ring to the underside of the AIO tap then pass all hoses through the 50mm hole.
Chiller connection BLUE
From Mixer OUT to Tap - Vented version only
Boiler connection RED
Blue ring on RHS mains IN to Mixer IN
White ringon LHS to Mains in
Tap
O ring Base
Clear tube to Vent
Note VENTILATION IS ESSENTIAL Read ‘Step 2’ ‘Ventilation’ before you start.
802263UK - Residential Chilled - Quick start guide - Sept 2016 - V2.03
Step 3- Installing the Command-CentreTM.
Note The braided hose and connection tubes cannot be lengthened. Use insulation supplied to cover the blue chilled water tube.
Command-CentreTM installation
BLU
E
BR
AID
ED
POWERCABLE
USBMAINS IN
CHILLEDOUT
280mm
Note Ambient mains water braided hose length is 750mm.Electrical power
cable length is 3.0m nom.
Position the Command-CentreTM
according to the hose and cable lengths
supplied.
Clearance Envelope
535m
m
50mm50mm
Note All silicon tubes / plastic pipes must be cut to size. They must have
a constant fall back to the Command-CentreTM.
Example HydroTap®G4 Classic chilled model (for Arc / Cube, also refer to the tube kit assembly instructions supplied with the tap head).
Arc / Cube Elite Classic
Commissioning
OPEN Position
CLOSED Position
ON
OFF
Stop cock
Filter flushHave a bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation. Open the filter access door on the front of the Command-CentreTM and the filter cartridge will be exposed. Located to the rear right hand side of the cartridge is a flush line, approx 600mm long, and the flush line stop cock. Place the free end of the flush line into the bucket or container (not supplied).
Note at first commissioning, the system will select the filter flush screen automatically.
Step 4- Commissioning.
Initial commissioning screen
To set the language
• Press the [Language] button for main menu.
• Select [English] or [Deutsch].
Language selection screen
Step 2- Cut cupboard holes and fit the air vent ducts.
Ventilation
Ventilation for all models • The clearance envelope dimensions stated in the specification sheets and
installation instructions must be observed.• Adequate ventilation must be provided to ensure that the cupboard space
temperature does not exceed 350C.
Preferred arrangement
4mm door buffers (at the four corners of each door) supplied with the Command-CentreTM should be used to provide adequate ventilation in normal usage, (as shown in the diagram below).
Door buffer
Braided hose fitting Install the mains water braided hoses to the Command-CentreTM before locating in place.
Zip Chilled Zip Chilled
Prepare filter flush as per instructions and press START
03:01 PM, TUE 12, Feb 2013BoilingZip
START STOP
NEXT
Zip Chilled
To calibrate flow sensorpress START button
NEXT
03:01 PM, TUE 12, Feb 2013ChilledZip
START
Pulses/L (360 - 440)
• Press [START] / [STOP] button to start and stop the filter flush.
• Turn the flush stop cock on.• Allow at least 10 litres of water to flush
through the filter.• Once the filter flush is finished, Turn
the stop cock off then press [STOP] to end filter flush mode.
• Press [NEXT] for the flow calibration screen.
The HydroTap®G4 is now ready to be commissioned. • Turn the electrical power on at the mains and the ON/OFF switch on the
side of the Command-CentreTM.• Turn the water on and check for any leaks.• Familiarise yourself with the operation of the tap, in preparation for use.
Important See Command-CentreTM installation, adjacent.