2
QUICK SET-UP GUIDE FOR AQUA SMART® SYSTEM FRONT FOR DETAILED INSTRUCTIONS FOR EACH FEATURE SIDE AND FUNCTION, SEE OWNER’S MANUAL. © 2012 AQUA SMART, INC. STEP 1: TURN OFF POWER. STEP 2. REMOVE WIRING FROM WATER HEATER 1. TURN OFF POWER TO WATER HEATER 2. REMOVER WATER HEATER JUNCTION BOX COVERS 3. TO BE SURE POWER IS OFF, TEST WIRES WITH CIRCUIT TESTER 4. REMOVE WIRES FROM WATER HEATER STEP 3: ATTACH RECEIVER BASE TO THE WATER HEATER 5. POSITION RECEIVER BASE OVER WATER HEATER JUNCTION BOX AND MARK FOR DRILLING 6. DRILL MOUNTING HOLES ON TOP OF WATER HEATER 7. ATTACH THE RECEIVERBASE TO TOP OF WATER HEATER WITH SCREWS IMPORTANT: BE SURE TO ATTACH GROUND WIRE TO WATER HEATER 8. REATTACH INCOMING CONNECTOR/WIRES TO BASE STEP 4: INSTALL MTA (MAGNETIC THERMAL-SENSOR ASSEMBLY) VERY IMPORTANT INSTRUCTIONS THE PROPER INSTALLATION OF THE MTA IS ONE OF MOST IMPORTANT STEPS IN THE INSTALLATION OF THE AQUA SMART® SYSTEM. THIS COMPONENT CONTROLS THE REMOTE TEMPERATURE OPERATIONS OF THE SYSTEM AND SUFFICIENT ATTENTION MUST BE PAID TO THE PROPER PLACEMENT OF THE MTA 1 2 3 4 5 Exiting the back of the receiver, locate the MTA consisting of a wire attached to a thermal-sensor and magnet, encased in a plastic box. The MTA is to be attached to the METAL WATER TANK of the hot water heater, as illustrated above. 1. Remove the top access panel. 2. Expose the “on-board” thermostat removing any insulation and the plastic protector (if one) covering the thermostat. Then, view the areas near the thermostat that show exposed the metal tank. 3. There are 2 preferred areas, next to the “on-board” thermostat, where the metal tank is exposed, marked with a ( * ), in the above illustration. In most water heaters, the best location is to the LEFT of the thermostat. 4. Position the MTA against the bare metal on water the tank. The magnet should firmly attach the MTA to the metal. Be sure the “rib” on the top of the MTA faces out. 5. Replace access panel and replace receiver cover. The MTA records the temperature of the water tank and sends the temperature reading to the RECEIVER. The RECEIVER then sends the data to the TRANSMITTER. This step is necessary to minimalize the effects of any ambient temperature differences between the THERMAL-SENSOR head and the location of the water heater. Review OWNER’S MANUAL for importance of installation of the MTA (MAGNETIC THERMAL-SENSOR ASSEMBLY). * *

QUICK SET-UP GUIDE FOR AQUA SMART® SYSTEM FRONT … · 2019. 12. 6. · REVIEW OWNERS MANUAL FOR THESE 2 SET-UP PROCEEDURES STEP 8: PROGRAMMING THE AQUA SMART® TRANSMITTER The AQUA

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: QUICK SET-UP GUIDE FOR AQUA SMART® SYSTEM FRONT … · 2019. 12. 6. · REVIEW OWNERS MANUAL FOR THESE 2 SET-UP PROCEEDURES STEP 8: PROGRAMMING THE AQUA SMART® TRANSMITTER The AQUA

QUICK SET-UP GUIDE FOR AQUA SMART® SYSTEM FRONT FOR DETAILED INSTRUCTIONS FOR EACH FEATURE SIDE AND FUNCTION, SEE OWNER’S MANUAL. © 2012 AQUA SMART, INC.

STEP 1: TURN OFF POWER. STEP 2. REMOVE WIRING FROM WATER HEATER

1. TURN OFF POWER TO WATER HEATER 2. REMOVER WATER HEATER JUNCTION BOX COVERS 3. TO BE SURE POWER IS OFF, TEST WIRES WITH CIRCUIT TESTER 4. REMOVE WIRES FROM WATER HEATER

STEP 3: ATTACH RECEIVER BASE TO THE WATER HEATER

5. POSITION RECEIVER BASE OVER WATER HEATER JUNCTION BOX AND MARK FOR DRILLING 6. DRILL MOUNTING HOLES ON TOP OF WATER HEATER 7. ATTACH THE RECEIVERBASE TO TOP OF WATER HEATER WITH SCREWS IMPORTANT: BE SURE TO ATTACH GROUND WIRE TO WATER HEATER 8. REATTACH INCOMING CONNECTOR/WIRES TO BASE

STEP 4: INSTALL MTA (MAGNETIC THERMAL-SENSOR ASSEMBLY) VERY IMPORTANT INSTRUCTIONS THE PROPER INSTALLATION OF THE MTA IS ONE OF MOST IMPORTANT STEPS IN THE INSTALLATION OF THE AQUA SMART® SYSTEM. THIS COMPONENT CONTROLS THE REMOTE TEMPERATURE OPERATIONS OF THE SYSTEM AND SUFFICIENT ATTENTION MUST BE PAID TO THE PROPER PLACEMENT OF THE MTA 1 2 3 4 5 Exiting the back of the receiver, locate the MTA consisting of a wire attached to a thermal-sensor and magnet, encased in a plastic box. The MTA is to be attached to the METAL WATER TANK of the hot water heater, as illustrated above. 1. Remove the top access panel. 2. Expose the “on-board” thermostat removing any insulation and the plastic protector (if one) covering the thermostat. Then, view the areas near the thermostat that show exposed the metal tank. 3. There are 2 preferred areas, next to the “on-board” thermostat, where the metal tank is exposed, marked with a ( * ), in the above illustration. In most water heaters, the best location is to the LEFT of the thermostat. 4. Position the MTA against the bare metal on water the tank. The magnet should firmly attach the MTA to the metal. Be sure the “rib” on the top of the MTA faces out. 5. Replace access panel and replace receiver cover. The MTA records the temperature of the water tank and sends the temperature reading to the RECEIVER. The RECEIVER then sends the data to the TRANSMITTER. This step is necessary to minimalize the effects of any ambient temperature differences between the THERMAL-SENSOR head and the location of the water heater. Review OWNER’S MANUAL for importance of installation of the MTA (MAGNETIC THERMAL-SENSOR ASSEMBLY).

*

*

Page 2: QUICK SET-UP GUIDE FOR AQUA SMART® SYSTEM FRONT … · 2019. 12. 6. · REVIEW OWNERS MANUAL FOR THESE 2 SET-UP PROCEEDURES STEP 8: PROGRAMMING THE AQUA SMART® TRANSMITTER The AQUA

QUICK SET-UP GUIDE FOR AQUA SMART® SYSTEM BACK FOR DETAILED INSTRUCTIONS FOR EACH FEATURE SIDE AND FUNCTION, SEE OWNER’S MANUAL © 2012 AQUA SMART, INC.

SWITCH IN AUTO POSITION

STEP 7: INITIAL SET-UP OF TRANSMITTER INITIAL SET-UP: Push and hold SET button for more than 5 seconds to enter into initial set-up. The initial settings include settings for TIME, °F/°C conversion, DAY of the Week, BALANCING and WATTAGE of Water Heater.

FOLLOW THE PROMPTS TO SET THE VARIOUS SETTIGS ON THE TRANSMITTER

STEP 6: TRANSMITTER SET-UP TWO IMPORTANT SETTINGS THAT MUST BE MADE OR THE SYSTEM WILL NOT ACCURATELY CALCULATE DATA. IT IS RECOMMENDED THAT USER REVIEW THESE TWO SET-UP PROCEEDURES, AT THIS TIME, SO THAT THE DATA REQUIRED IS READILY AVAILABLE TO ENTER INTO THE TRANSMITTER WHEN PROMPTED. #1 - BALANCING FEATURE

#2 - WATER HEATER WATTAGE RATING REVIEW OWNERS MANUAL FOR THESE CRITICAL SET-UP PROCEEDURES

BALANCING THE THERMAL SENSOR TEMPERATURE: During the initial set-up process, user MUST adjust the SENSOR TEMP to the actual water temperature coming from a HOT water faucet in the home. A small THERMOMETER has been supplied to allow user to measure the ACTUAL temperature of the hot water coming out of a water faucet supplied by the water heater. User can compare this reading to the SENSOR TEMP reading on the LCD screen. WATER HEATER WATTAGE RATING:

The water heater WATTAGE rating must be entered into the transmitter during the INITIAL SET- UP procedure. User MUST match the WATTAGE rating of the water heater to the RECEIVER that the AQUA SMART® has been installed on. This procedure is necessary to allow the system’s software to accurately calculate the kWh electrical usage when the water heater is operating. REVIEW OWNERS MANUAL FOR THESE 2 SET-UP PROCEEDURES

STEP 8: PROGRAMMING THE AQUA SMART® TRANSMITTER The AQUA SMART® can operate from a factory-installed program or one entered by the user. A description of both these programs can be found in the owner’s manual with reprogramming instructions.

STEP 9: PROGRAMMING THE RECEIVER Each transmitter for the AQUA SMART® system has one of 1,048,576 unique security codes embedded into its memory. It will be necessary to program the RECEIVER to LEARN the security code of the transmitter, upon initial use. 1. Standing approximately 3 feet from the hot water heater, where the RECEIVER has been permanently mounted, program the transmitter’s security code into the RECEIVER. 2. To program the RECEIVER to LEARN the transmitter's security code, push the LEARN button on top of the RECEIVER case. There will be a LONG BEEP signaling that the RECEIVER is ready to learn the transmitter’s security Code. 3. Now press the MODE button on the transmitter and 5 RAPID BEEPS will be heard confirming that the LEARN process has been completed. When first powered, all 4 of the LEDs, on the RECEIVER, will remain ON for a short period of time confirming that the LEDs are operational. FOLLOW ADDITIONAL PROGRAMMING INSTRUCTIONS AS WELL AS THE OPERATION OF THE 4 MODES IN THE OWNER’S MANUAL.

MODE

SET UP/DOWN BUTTONS

STEP 5: CONNECT THE INCOMING POWER LINES TO THE RECEIVER IMPORTANT IMPORTANT IMPORTANT IT IS CRITICAL TO FOLLOW THESE WIRING CONNECTIONS FOR RELIABLE OPERATION OF THE AQUA SMART® SYSTEM AND TO RESTART THE WATER HEATER’S OPERATION.