2
MOBILE APP Go to the tab on the Controller Settings page. WEB Use Alerts Page, or Multi-Controller Alert Report from weathertrak.net. CONTROLLER While at the controller, use the following process: Press Button. The first screen is the showing any alert or warning that exists on your controller. Each two letter code is an Alert Category. An or appear beneath any category that has an alert present. Flow Alerts — Issue with flow hardware or flow feature programming. Fix the issue, then press button to clear alert then retest Valve Alerts — Issue with valve electrical components or connections. Fix the issue, then press button to clear alert then retest Communication Alerts — Reset GPRS Status or call Customer Service for assistance Water Window Warning — Calculated irrigation schedule exceeds the allowable irrigation time programmed Water Window Water Day Warning — Calculated irrigation schedule exceeds number of allowable Water Days programmed in Water Day Mode Station High Depletion — Reset Station Depletion from Manage Page of weathertrak.net or from Help menu — “Help : 12 — Current Depletion” Hardware Alert — Issue with controller hardware. Call Customer Service for assistance Subscription Alert — Call Customer Service to update data service plan : : : : : : : : TROUBLESHOOTING If you suspect that there is an issue with your WeatherTRAK Controller hardware, we have easy to use LED diagnostic lights on the controller chassis. Remove the controller panel from its mounted to position to completely reveal the controller chassis. Use the chassis diagram above to identify each of the six LED Diagnostic lights on the chassis and check to see if each is illuminated. Then, compare result to the diagnostic table and take appropriate action. Contact Customer Support with any questions: 800.362.8774 or [email protected]. BASIC TASKS ACTIVATE Access this controller from WeatherTRAK.net or WeatherTRAK Mobile Call Customer Support at: 800.362.8774 Fill out the activation form at: hydropoint.com/activate SET CONTROLLER MODE Controller On/Off, Shutdown, or Winterized • Press button • Use button to select desired function To clear Shutdown or Winterized, press Button, then press to reset the status SITE CHECK Manual Operation / Wet Check Use “Manual” Feature on WeatherTRAK Mobile • Press Manual Test button. Then select: By Station to operate a single station All Stations to operate all stations sequentially By Program to operate all stations assigned to the same program ADJUST Landscape too wet or too dry Use “% Adjust” Feature on WeatherTRAK Mobile Press Adjust button: Use button to select desired station Use or buttons to make desired adjustments ALERT MANAGEMENT 04012019 QUICK REFERENCE CARD MV1 VC FL1 VC

QUICK REFERENCE CARD - HydroPoint · riego calculado excede el número de días de agua permitidos programados en modo día agua Estación Depleción Alta — Reinicializar Station

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: QUICK REFERENCE CARD - HydroPoint · riego calculado excede el número de días de agua permitidos programados en modo día agua Estación Depleción Alta — Reinicializar Station

MOBILE APPGo to the ������ tab on the Controller Settings page.

WEBUse Alerts Page, or Multi-Controller Alert Report from weathertrak.net.

CONTROLLERWhile at the controller, use the following process:Press ������ Button. The first screen is the ������ �������� showing any alert or warning that exists on your controller. Each two letter code is an Alert Category. An �� or �� appear beneath any category that has an alert present.

Flow Alerts — Issue with flow hardware or flow feature programming. Fix the issue, then press button to clear alert then retestValve Alerts — Issue with valve electrical components or connections. Fix the issue, then press button to clear alert then retestCommunication Alerts — Reset GPRS Status or call Customer Service for assistanceWater Window Warning — Calculated irrigation schedule exceeds the allowable irrigation time programmed Water WindowWater Day Warning — Calculated irrigation schedule exceeds number of allowable Water Days programmed in Water Day ModeStation High Depletion — Reset Station Depletion from Manage Page of weathertrak.net or from Help menu — “Help : 12 — Current Depletion”Hardware Alert — Issue with controller hardware. Call Customer Service for assistanceSubscription Alert — Call Customer Service to update data service plan

��:

��:

��:

� :

�:

� :

��:

:

TROUBLESHOOTINGIf you suspect that there is an issue with your WeatherTRAK Controller hardware, we have easy to use LED diagnostic lights on the controller chassis.

Remove the controller panel from its mounted to position to completely reveal the controller chassis.

Use the chassis diagram above to identify each of the six LED Diagnostic lights on the chassis and check to see if each is illuminated. Then, compare result to the diagnostic table and take appropriate action.

Contact Customer Support with any questions: 800.362.8774 or [email protected].

BASIC TASKSACTIVATEAccess this controller from WeatherTRAK.net or WeatherTRAK Mobile

• Call Customer Support at: 800.362.8774• Fill out the activation form at: hydropoint.com/activate

SET CONTROLLER MODEController On/Off, Shutdown, or Winterized

• Press ��� button • Use button to select desired function• To clear Shutdown or Winterized, press ��� Button, then press to reset the status

SITE CHECKManual Operation / Wet Check

• Use “Manual” Feature on WeatherTRAK Mobile• Press Manual Test button. Then select:

• By Station to operate a single station• All Stations to operate all stations sequentially• By Program to operate all stations assigned

to the same program

ADJUSTLandscape too wet or too dry

• Use “% Adjust” Feature on WeatherTRAK Mobile• Press Adjust button:

• Use button to select desired station• Use or buttons to make desired

adjustments

ALERT MANAGEMENT

0401

2019

�����������������������

����� ������������������

���������������

��������������������

����

���� ­������

���������������

����

���

��

��

�����������������������������

����� ����������� �

����������������� �������

������ �������� ������������������

�������������������������������

���� ����� �������������������������

QUICK REFERENCE CARD

MV1

VCFL1

VC

���������� ����������

Page 2: QUICK REFERENCE CARD - HydroPoint · riego calculado excede el número de días de agua permitidos programados en modo día agua Estación Depleción Alta — Reinicializar Station

APLICACIÓN MOVILUtilice alertas activas Función de WeatherTRAK MobileWEBUtilice la página de alertas, o el informe de alerta de multi-con-trolador de weathertrak.net.

CONTROLADORMientras esté en el controlador, utilice el siguiente proceso:Presiona el botón de alertas. La primera pantalla es la resumen de alertas. Mostrando cualquier alerta o advertencia de que existe en su controlador. Cada código de dos letras es una categoría de alerta. Un “ER” o “WA” aparecen debajo de cualquier categoría que tiene una alerta presente.

Alertas de flujo — Problema con el flujo de hardware o programación de funciones de flujo. Solucione el problema, luego presione el botón para borrar la alerta y vuelva a probarAlertas de válvulas — Problema con componentes eléctricos de la válvula o conexiones. Solucione el problema, luego presione el botón para borrar la alerta y vuelva a probarAlertas de comunicación — Restablezca el estado de GPRS o llame al servicio de atención al cliente para obtener ayudaAdvertencia de ventana de agua — El programa de riego calculado excede el tiempo de riego programadoAdvertencia sobre el Día del Agua — El programa de riego calculado excede el número de días de agua permitidos programados en modo día aguaEstación Depleción Alta — Reinicializar Station Depleción Desde la página de administración en weathertrak.net o desde el menú de ayuda — ”Help:12 — Current Depletion”Alerta de hardware — Problema con el hardware del controlador. Llame al Servicio de Atención al Cliente para obtener ayudaAlerta de Suscripción — Llame al Servicio de Atención para actualizar el plan de servicio de datos

FL:

VL:

CM:

WD:

DY:

HD:

HW:

SB:

SOLUCIÓN DE PROBLEMASSi sospecha que hay un problema con el hardware del controlador WeatherTRAK, tenemos fáciles de usar luces LED de diagnóstico en el chasis del controlador.

Retire el módulo de mando del controlador o el panel de su posición montada para revelar completamente el tablero de terminales del cable de la válvula.

Utilice el diagrama de chasis que se muestra arriba, para identificar cada una de las seis diagnóstico luces de LED en el chasis y compruebe si están iluminado. Compare el resultado con el diagrama de diagnóstico y tome las medidas apropiadas.

Póngase en contacto con el servicio de atención al cliente si tiene alguna pregunta: 800.362.8774, [email protected]

OPERACIONES BÁSICASACTIVARPara iniciar el acceso a este controlador a travésde WeatherTRAK.net o WeatherTRAK Mobile

• llama a Atención al cliente: 1.800.362.8774• Enviar tu información de contacto y información del controlador [email protected]

AJUSTE DE MODOControlador Encendido/Apagado, Apagar El Systema, Invierno modos

• Presiona el botón de APAGADO • Utiliza el botón para seleccionar la función deseada.• Para borrar el apagado del sistema o invierno modo,

presiona botón de APAGADO, y entonces presionaPara restablecer el estado.

COMPROBACIÓN DEL SITIOModo manual/Cheque húmedo

• Utilice la función "Manual" en WeatherTRAK Mobile• Presiona el botón de PRUEBA MANUAL. Luego seleccione:

• By Station para operar una sola estación• All Stations Para operar todas las estaciones secuencialmente• By Program Para operar todas las estaciones asignadas al

mismo programaAJUSTEPaisaje demasiado húmedo o demasiado seco

• Utilice la función “% Adjust” en WeatherTrak Mobile• Presiona el botón “Adjust”

• Utilice el botón para seleccionar la emisora deseada• Utilice los los botones o para realizar los

ajustes deseados

GESTOR DE ALERTAS

0401

2019

����������������������������������������

��������������������������

�������������������

��������������������������������

������������������������

����������������

����

���

��

��

����������������������

�� ���������

������������������  ­�����

������������������������������������

�����������������������������������������­�

��������������������������� ��������

������������������������������������������

GUIA DE REFERENCIA RAPIDA

MV1

VCFL1

VC

��������������� ����������������� �