Page 1: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

L3 Multi-Port Full Gigabit Stackable Managed Switch

SGS-6340-24T4S / SGS-6340-24P4S /

SGS-6340-20S4C4X / SGS-6340-48T4S

Quick Installation Guide

Page 2: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

Table of Contents

1. Package Contents ....................................................................................... 3

2. Switch Management .................................................................................... 4

3. Requirements ............................................................................................. 5

4. Terminal Setup ........................................................................................... 6

5. Logon to the Console .................................................................................. 7

6. ConfiguringIPAddress ................................................................................ 8

7. Setting100BASE-FXforSFPPort(SGS-6340-20S4C4XOnly) ........................10

8. UsingCopperInterfaceonComboPort(SGS-6340-20S4C4XOnly) ................11

9. SavingtheConfiguration ............................................................................12

10.StartingWebManagement .........................................................................13

11.LoggingintotheManagedSwitch ..............................................................14

12.SavingConfigurationviatheWeb ...............................................................15

13. Customer Support .....................................................................................16

Page 3: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

3

1. Package ContentsThank you for purchasing PLANET L3 Multi-Port Full Gigabit Stackable ManagedSwitch, SGS-6340-24T4S/SGS-6340-24P4S/SGS-6340-20S4C4X/SGS-6340-48T4S.Thedescriptionsofthesemodelsareasfollows:

SGS-6340-24T4SLayer324-Port10/100/1000T+4-Port1000XSFPStackableManagedSwitch

SGS-6340-24P4SLayer324-Port10/100/1000T802.3atPoE+4-Port1000XSFPStackableManagedSwitch/370W

SGS-6340-20S4C4XLayer320-Port100/1000XSFP+4-PortGigabitTP/SFP+4-Port10GSFP+StackableManagedSwitch

SGS-6340-48T4SLayer348-Port10/100/1000T+4-Port1000XSFPStackableManagedSwitch

Unless specified, “Managed Switch” mentioned in this Quick Installation Guidereferstotheabovefourmodels.

Open the box of theManaged Switch and carefully unpack it. The box shouldcontainthefollowingitems:

z TheManagedSwitchx1

z QuickInstallationGuidex1

z RJ45-to-DB9ConsoleCablex1

z PowerCordx1

z RubberFeetx4

z TwoRack-mountingBracketswithAttachmentScrewsx1

z SFPDustCap(Pleaserefertotablebelow)

SFPDustCap ModelName

4 SGS-6340-24T4S/24P4S/48T4S

28 SGS-6340-20S4C4X

If any item is found missing or damaged, please contact your local reseller forreplacement.

Page 4: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

4

2. Switch ManagementTo set up the Managed Switch, the user needs to configure the Managed Switchfornetworkmanagement.TheManagedSwitchprovidestwomanagementoptions:Out-of-Band ManagementandIn-Band Management.

Out-of-Band ManagementOut-of-band management is the management through Console interface.Generally, the user will use out-of-band management for the initial switch configuration,orwhenin-bandmanagementisnotavailable.

Important

The Managed Switch is shipped without IP address assigned bydefault.UsermustassignanIPaddresstotheManagedSwitchviathe Console interface to be able to remotely access the ManagedSwitch through Telnet or HTTP.

In-Band ManagementIn-band management refers to the management by logging in to the ManagedSwitchusingTelnetorHTTP,orusingSNMPmanagementsoftwaretoconfiguretheManaged Switch. In-bandmanagement enables themanagement of theManagedSwitchtoattachsomedevicestotheSwitch.ThefollowingproceduresarerequiredtoenableIn-bandmanagement:

1. Logon to console

2.Assign/ConfigureIPaddress

3. Create a remote login account

4.EnableHTTPorTelnetserverontheManagedSwitch

In case in-bandmanagement fails due to Managed Switch configuration changes,out-of-bandmanagement canbeused for configuringandmanaging theManagedSwitch.

Page 5: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

5

3. Requirements z Workstations running Windows XP/2003/Vista/7/8/2008, MAC OS X or later,Linux,UNIX,orotherplatformsarecompatiblewithTCP/IPprotocols.

z WorkstationsareinstalledwithEthernetNIC(NetworkInterfaceCard)

z SerialPortConnection(Terminal)

The above Workstations come with COM Port (DB9) or USB-to-RS232converter.

The aboveWorkstations have been installed with terminal emulator, such asTera Term or PuTTY.

Serial cable -- one end is attached to theRS232 serial port,while the otherendtotheconsoleportoftheManagedSwitch.

z EthernetPortConnection

Networkcables--Usestandardnetwork(UTP)cableswithRJ45connectors.

The above PC is installed with Web browser and JAVA runtime environmentplug-in.

Note

It is recommendedtouseInternetExplore8.0orabovetoaccesstheManaged Switch. If theWeb interface of theManaged Switchisnotaccessible,please turnoff theanti-virussoftwareor firewallandthentryitagain.

Page 6: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

6

4. Terminal SetupTo configure the system, connect a serial cable to a COM port on a PC or notebook computer and to serial (console) port of the Managed Switch. Theconsole port of theManaged Switch is DCE already, so that you can connect theconsoleportdirectlythroughPCwithouttheneedofNullModem.

Managed Switch

PC / Workstationwith

Terminal Emulation Software

Serial Port

RS232 to RJ45 Cable

Console PortRJ45

Figure 4-1 Managed Switch Console Connectivity

Note

Let’stakeSGS-6340-48T4Sforexample.

A terminal program is required tomake the software connection to the ManagedSwitch.TeraTermprogrammaybeagoodchoice.TheTeraTermcanbeaccessedfromtheStart menu.

1. Click START menu, then Programs,andthenTera Term.

2.When the following screen appears, make sure that the COM port should beconfiguredas:

Baud: 9600Parity: NoneDatabits: 8Stopbits: 1Flowcontrol: None

Figure 4-2 Tera Term COM Port Configuration

Page 7: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

7

5. Logon to the ConsoleOnce the terminal is connected to thedevice,poweron theManagedSwitch,andtheterminalwilldisplay“running testing procedures”.

Then, the following message asks for the login user name and password. Thefactory default user name and password are as follows as the login screen inFigure5-1appears.

Username:admin

Password:admin

Figure 5-1 Managed Switch Console Login Screen

The user can now enter commands to manage the Switch. For a detaileddescriptionofthecommands,pleaserefertothefollowingchapters.

Note

1.Forsecurityreason,pleasechangeandmemorizethenewpass-wordafterthisfirstsetup.

2.Only accept command in lowercase letter under console inter-face.

Page 8: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

8

6.ConfiguringIPAddressThe IP address configuration commands for VLAN1 interface are listed below.Before using in-bandmanagement, the Managed Switchmust be configured withan IP address by out-of-bandmanagement (i.e. consolemode). The configurationcommandsareasfollows:

SGS-6340-48T4S#configSGS-6340-48T4S(config)# interface vlan 1SGS-6340-48T4S(config-if-Vlan1)#ip address 192.168.1.254 255.255.255.0

ThepreviouscommandwouldapplythefollowsettingsfortheManagedSwitch.

IPv4 Address: 192.168.1.254Subnet Mask: 255.255.255.0

Figure 6-1 Configuring IPv4 Address Screen

To check the current IP address or modify a new IP address for the ManagedSwitch,pleaseusetheproceduresasfollows:

Show the current IP address1.On “SGS-6340-48T4S#” prompt, enter “show ip interface brief”.

2.ThescreendisplaysthecurrentIPaddress,SubnetMaskandGatewayasshowninFigure6-2.

Figure 6-2 Showing IP Information Screen

Page 9: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

9

If the IP is successfully configured, the Managed Switch will apply the new IPaddresssetting immediately.Youcanaccess theWeb interfaceofManagedSwitchthroughthenewIPaddress.

Note

Ifyouarenotfamiliarwithconsolecommandortherelatedparam-eter,enter“help”anytimeinconsoletogetthehelpdescription.

Page 10: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

10

7.Setting100BASE-FXforSFPPort(SGS-6340-20S4C4XOnly)

The Managed Switch supports both 1000BASE-X and 100BASE-FX SFPtransceiverbymanual settingand thedefaultSFPport speed is set to1000Mbps.To establish the fiber connection with 100BASE-FX SFP transceiver, the followingcommandconfigurationisrequired:

SGS-6340-20S4C4X#config

SGS-6340-20S4C4X(config)#interface ethernet 1/0/1-20

SGS-6340-20S4C4X(config-if-port-range)#speed-duplex force100-fx

module-type auto-detected

SGS-6340-20S4C4X(config-if-port-range)#exit

SGS-6340-20S4C4X(config)#interface ethernet 1/0/21-24

SGS-6340-20S4C4X(config-if-port-range)#media-type fiber

SGS-6340-20S4C4X(config-if-port-range)#speed-duplex force100-fx

module-type auto-detected

SGS-6340-20S4C4X(config-if-port-range)#

Figure 7-1 Setting 100BASE-FX Screen

Page 11: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

11

8.UsingCopperInterfaceonComboPort(SGS-6340-20S4C4XOnly)

The Managed Switch’s combo port has SFP and copper interface and the defaultcombo port type is SFP port only. To establish the combo port connection withcopperinterface,thefollowingcommandconfigurationisrequired:

SGS-6340-20S4C4X#configSGS-6340-20S4C4X(config)#interface ethernet 1/0/21-24SGS-6340-20S4C4X(config-if-port-range)#media-type copper

Figure 8-1 Using Copper Interface Screen

Page 12: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

12

9.SavingtheConfigurationIn Managed Switch, the running configuration file stores in the RAM. In thecurrent version, the running configuration sequence running-config can be savedfrom the RAM to FLASH bywrite command or copy running-config startup-configcommand,sothattherunningconfigurationsequencebecomesthestart-upconfigurationfile,whichiscalledconfigurationsave.

SGS-6340-48T4S#copy running-config startup-config

Figure 9-1 Copying Running-config Startup-config Screen

Page 13: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

13

10.StartingWebManagementThe Managed Switch provides a built-in browser interface. You can manage itremotely by having a remote host with Web browser, such as Microsoft InternetExplorer,MozillaFirefox,GoogleChromeorAppleSafari.

PC / Workstationwith Web Browser

192.168.0.x

Managed Switch

RJ45/UTP Cable

IP Address:192.168.0.100

Figure 10-1 IP Management Diagram

The following shows how to start-up the Web Management of the ManagedSwitch. Please note the Managed Switch is configured through an Ethernetconnection. Please make sure the manager PC must be set on the same IP subnet address.

For example, the IP address of the Managed Switch is configured with192.168.0.100, then the manager PC should be set at 192.168.0.x (where xis a number between 1 and 253, except 100), and the default subnet mask is255.255.255.0.

Thefactorydefaultusernameandpasswordareasfollows:

Username:adminPassword:admin

Page 14: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

14

11.LoggingintotheManagedSwitch1.Use Internet Explorer 8.0 or above Web browser and enter IP address

http://192.168.1.254 (that you have just set in console) to access theWebinterface.

2.When the following dialog box appears, please enter the configured username“admin”andpassword“admin”(ortheusername/passwordyouhavechangedviaconsole).TheloginscreeninFigure11-1appears.

Figure 11-1 Login Screen

3.Afterenteringthepassword,themainscreenappearsasshowninFigure11-2.

Figure 11-2 Web Main Screen of Managed Switch

4.TheSwitchMenuonthe leftoftheWebpage letsyouaccessall thecommandsandstatisticstheSwitchprovides.

Now, you can use the Web management interface to continue the Switchmanagementormanage theManagedSwitchby console interface.Please refer totheusermanualformore.

Page 15: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

15

12.SavingConfigurationviatheWebIn the Managed Switch, the running configuration file stores in the RAM. In thecurrentversion,therunningconfigurationsequenceofrunning-configcanbesavedfrom the RAM to FLASH by “Save current running-configurations” function,so that the running configuration sequencebecomes the startup configurationfile,whichiscalledconfigurationsave.

To save all applied changes and set the current configuration as a startupconfiguration, the startup-configuration file will be loaded automatically across asystemreboot.

1. Click “Switch basic configuration > Switch basic configuration > Save current running-configuration” to login “Save current running-configuration”Page.

2. Press the “Apply” button to save current running-configuration to start upconfiguration.

Page 16: Quick Installation Guide - planet.com.tw Series_v1... · Network cables -- Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser and JAVA

16

13. Customer SupportThank you for purchasing PLANET products. You can browse our online FAQresourceat thePLANETWeb sitefirst to check if it could solveyour issue. If youneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.

PLANETonlineFAQ:http://www.planet.com.tw/en/support/faq.php?type=1

Switchsupportteammailaddress:[email protected]

SGS-6340-24T4S/SGS-6330-24P4S/SGS-6330-20S4C4X/SGS-6330-48T4SUser’sManualhttp://www.planet.com.tw/en/support/download.php?type1=1&model=&type=3#list

Copyright © PLANET Technology Corp. 2015.Contents are subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.