19
QUANTITY SURVEY REPORT Not for Bank Use Source: Google Maps Project: Proposed Boarding House Development At No. 3 Homebush Road Strathfield NSW 2135 Applicant: Urban Link Pty Ltd Builder: Developer Managed Report Date: 1 May 2017

QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

  • Upload
    votram

  • View
    213

  • Download
    1

Embed Size (px)

Citation preview

Page 1: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

QUANTITY SURVEY REPORT

Not for Bank Use

Source: Google Maps

Project: Proposed Boarding House Development At No. 3 Homebush Road Strathfield NSW 2135

Applicant: Urban Link Pty Ltd

Builder: Developer Managed

Report Date: 1 May 2017

Page 2: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) Quantity Surveyor Report – DA Submission only (Not for Bank Use) 3 Homebush Rd, Strathfield

2 | P a g e

Table of Contents 1. Instruction .............................................................................................................. 3

2. Brief Development Description ............................................................................. 3

3. Construction Cost Estimate ................................................................................... 3

4. Areas ...................................................................................................................... 4

5. Quality of Finishes .................................................................................................. 5

6. Documentation ...................................................................................................... 5

7. Exclusions ............................................................................................................... 5

8. Design Assumptions / Parameters ......................................................................... 6

9. Contingency Allowance .......................................................................................... 6

10. Disclaimer .............................................................................................................. 6

Appendix A Council Schedule Appendix B Elemental Cost Estimate Summary Appendix C Assumed Schedule of Finishes Appendix D Reduced Architectural Drawings

Page 3: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) Quantity Surveyor Report – DA Submission only (Not for Bank Use) 3 Homebush Rd, Strathfield

3 | P a g e

1. Instruction We have undertaken a study of the probable cost of construction for the above project, based on the supplied architectural drawings and other information provided. We have also taken into consideration the proposed method of procurement (Developer Managed). 2. Brief Development Description

The proposal includes the demolition of existing structure(s) and the construction of a four (4) storey Boarding House with associated basement car parking, at No. 3 Homebush Rd, Strathfield. The proposed development consists of:

• Ten (10) x Car Parking Spaces within a single basement level;

• Thirty six (36) x Boarding Rooms within Ground Floor to Level 3;

• One (1) x Common Room within Ground Floor.

Typically, each boarding room comprises an open plan bedroom/living area, bathroom and kitchenette. 3. Construction Cost Estimate

Description Amount ($)

Total Construction Cost 3,541,090

Add Consultants Fees 75,289

Total Development Cost (excl. GST) 3,616,379

Add GST 361,638

Total Development Cost (incl. GST) 3,978,017 The required Council Schedule is attached in Appendix A. Also, please refer to Appendix B for an Elemental Cost Estimate Summary prepared in accordance with the Environmental Planning and Assessment Regulation 2000 (Reg 25J) - Section 94A Levy - Determination of proposed cost of Development. A detailed report may be obtained upon request. Our Construction Cost Estimate may be considered as reasonable, based on the proposed level of finishes and in the absence of the Structural and Services drawings, the Contract Documents and DA Conditions.

Page 4: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) Quantity Surveyor Report – DA Submission only (Not for Bank Use) 3 Homebush Rd, Strathfield

4 | P a g e

4. Areas

According to the architectural drawings, the proposed approximate Floor Areas may be presented as follows:

Building Level Description F.E.C.A*

(m2) U.C.A**

(m2) G.F.A***

Total (m2)

Basement Parking 455 455

Ground Floor Boarding Rooms 252 252

Ground Floor Common Area (incl. Common Lounge) 97 97

Level 1 Boarding Rooms 263 2 265

Level 1 Common Area 62 62

Level 2 Boarding Rooms 263 2 265

Level 2 Common Area 62 62

Level 3 Boarding Rooms 218 2 220

Level 3 Common Area 15 55 71

Total 1,688 61 1,749

*F.E.C.A (Fully Enclosed Covered Area): The sum of all such areas at all building floor levels, including basements (except unexcavated portions), floored roof spaces and attics, garages, penthouses, enclosed porches and attached enclosed covered ways alongside building, equipment rooms, lift shafts, vertical ducts, staircases and any other fully enclosed spaces and useable areas of the building, computed by measuring from the normal inside face of exterior walls but ignoring any projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include open courts, light wells, connecting or isolated covered ways and net open areas of upper portions of rooms, lobbies, halls interstitial spaces and the like which extend through the storey being computed. **U.C.A (Unenclosed Covered Area): The sum of all such areas at all building floor levels, including roofed balconies, open verandahs, porches and porticos, attached open covered ways alongside buildings, undercrofts and useable space under buildings, unenclosed access galleries (including ground floor) and any other trafficable covered areas of the building which are not totally enclosed by full height walls, computed by measuring the area between the enclosing walls or balustrade (ie. from the inside face of the UCA excluding the wall or balustrade thickness). When the covering element (i.e. roof or upper floor) is supported by columns, is cantilevered or is suspended, or any combination of these, the measurements shall be taken to the edge of the paving or to the edge of the cover, whichever is the lesser. UCA shall not include eaves overhangs, sun shading, awnings and the like where these do not relate to clearly defined trafficable covered areas, nor shall it include connecting or isolated covered ways. ***G.F.A (Gross Floor Area): The sum of the 'Fully Enclosed Covered Area' and 'Unenclosed Covered Area' as defined. The G.F.A definition used here is different to the Gross Building Area defined in the ANZRPGN 4 Methods of Measurement used by Valuation and Property Industry Professionals.

Page 5: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) Quantity Surveyor Report – DA Submission only (Not for Bank Use) 3 Homebush Rd, Strathfield

5 | P a g e

5. Quality of Finishes Finishes may be considered of Standard commercial quality, as described in the attached Schedule of Finishes (Appendix C), prepared by Construction Consultants (QS) and based on information supplied by the Developer. The quality of finishes proposed, are appropriate to the type, scale and location of this project. 6. Documentation Our Cost Estimate was based on Architectural Drawings prepared by Urban Link Pty Ltd, Project No. 2017-020, Drawing Nos. DA0001 to DA1001, DA1002, DA2001_A, DA2003_A to DA2005_A, DA2901 to DA2904, DA3001, DA3002, DA4001, DA6301 and DA6302, Revision A, Dated 10/02/2017. Please refer to Appendix D for a reduced copy of part of these drawings. 7. Exclusions Our Cost Estimate does not include the following:

- Land Acquisition; - Marketing and financing; - Legal costs; - Project Management; - Building insurance costs; - Major services diversions, external connections and /or improvement; - Amplification / amendment to existing services; - Underpinning of existing structure; - Amendments to plans, incomplete documentation; - Taxes, levies and charges; - Disabled access; - Energy and water efficiency; - Decontamination works (Asbestos Removal, etc); - Rock excavation; - Dewatering / Drainage pit & pump-out; - Blinds / Fly screens; - Loose Furniture / FF&E’s - External roadworks / Public domain works. - Authorities Fees (S94 Contribution and the like); - Contingency allowance;

Page 6: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) Quantity Surveyor Report – DA Submission only (Not for Bank Use) 3 Homebush Rd, Strathfield

6 | P a g e

8. Design Assumptions / Parameters In the absence of engineering drawings, the structure of the proposed buildings was assumed of conventional nature, comprising the following:

- Reinforced concrete soldier piles / shotcrete to basement shoring; - Reinforced concrete strip / pad footings; - Reinforced concrete columns and floor slabs (Framed structure).

Our Indicative Cost Estimate was based on the assumption that the whole development will be constructed in a single stage (i.e. not a staged development). If the building is to be completed in stages, the cost of preliminaries and Building services may increase. This Cost Estimate may provide no more than a rough guide to the probable cost of the proposed development. Costs may vary considerably, due to a range of variables:

- Further Geotechnical investigation; - Structural and services documentation; - Contract conditions; - Final PC Items and Provisional Allowances; - Variations in the proposed fixtures and finishes; - DA Conditions.

9. Contingency Allowance A Contingency Allowance (generally between 5% and 10%) will not be included for the purpose of this Report. 10. Disclaimer

This Certificate has been prepared for the sole purpose of providing an Initial Cost Estimate for DA Council Submission only (not for bank use). This Quantity Survey Certificate is not to be used for any other purpose. This Report is confidential to the developer. The Writer does not accept any contractual, tortuous or other form of liability for any consequences, loss or damage which may arise as a result of any other person acting upon or using this report. Report and estimate prepared by

Michael M. Dakhoul B. Build (Hons. 1) AAIQS MAIB MCIOB ICECA AAIQS Reg. No. 3618

Page 7: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Appendix A Council Schedule

Page 8: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include
Page 9: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Appendix B Elemental Cost Estimate Summary

Page 10: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Elemental Summary3 Homebush Rd, Strathfield

Code Item % Cost ($) / m2 Total Cost ($)

PR Preliminaries 12.06 249 436,196

AR Demolition 0.88 18 31,667

XP Site Preparation 0.09 2 3,167

SB

Substructure (Shoring, Excavation and Basement

Structure) 9.94 205 359,405

CL Columns 1.75 36 63,333

UF Upper floors 6.92 143 250,166

SC Staircases 1.36 28 49,083

RF Roof 1.31 27 47,500

EW External Walls 8.45 175 305,582

WW Windows 3.15 65 114,000

ED External Doors 0.70 14 25,333

NW Internal Walls 4.82 100 174,166

NS Internal Screens 0.66 14 23,750

ND Internal Doors 2.71 56 98,166

WF Wall Finishes 3.37 70 121,949

FF Floor Finishes 3.10 64 111,970

CF Ceiling Finishes 2.22 46 80,304

FT Fitments 3.69 76 133,478

PB Hydraulic Services (incl. External Services) 6.26 129 226,332

AC

Mechanical Services (Basement and wet areas

Ventilation, Air Conditioning if applicable) 2.22 46 80,316

FP Fire Services 0.85 17 30,606

LP Electrical Services 5.62 116 203,415

TS Transportation Services (Lifts, Escalators and the like) 2.98 62 107,666

XR/XN Siteworks (Boundary walls, Fencing and Gates, etc.) 1.32 27 47,817

XL Landscaping and Improvements 2.41 50 87,083

BM Builder's Margin 9.09 188 328,641

Total Construction Cost (excl. GST) 3,541,090

Add Consultants Fees 2.08 43 75,289

Total Development Cost (excl. GST) 100.00 2,068 3,616,379

Add GST 361,638

Total Development Cost (incl. GST) 3,978,017

Construction Consultants (QS)

1 of 1

1/05/2018

Page 11: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Appendix C Assumed Schedule of Finishes

Page 12: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) 1/05/2018

1

Proposed Boarding House 3 Homebush Rd, Strathfield

ASSUMED SCHEDULE OF FINISHES

BUILDING INTERIOR

Internal finishes and Fittings Internal Bathroom Doors Hollow core / plain / painted Room Front Doors Fire rated / plain / painted Door Handles Lockset to room doors Metal lever to internal doors Kitchen Stone benchtop and polyurethane doors Walls Generally face brickwork Ceilings Set plaster / painted Cornices Standard Cove

Bathroom Fittings Shower Screens Powder coated alum. Semi-Frameless / Safety glass WC Suite Vitreous China Suite with 6/3 dual flush Vanity Unit Laminated top with Semi-recessed basin Mirror Wall mounted mirror above each vanity unit Tapware Single Lever Mixer / Chrome Bathroom Fittings Stainless steel Floor Finishes Rooms Carpet Hallways Carpet Bathrooms Ceramic tiles Fixtures Hot water unit Basic Air conditioning Split system Intercom Excl. Alarm Excl. Transportation 1 Lift Exclusions – FF&Es Loose furniture Artworks Signage Beds & Mattresses Bedside tables Coffee table and kettle Office table and chairs Manchester and curtains Utensils Fridges / Microwaves Washing Machine / Dryers Heaters

Page 13: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Construction Consultants (QS) 1/05/2018

2

BUILDING EXTERIOR External walls Refer to architectural drawings Windows and sliding doors Powder coat / aluminum framed Handrails / balustrades Powder coated metal Roof Refer to architectural drawings Individual Garage Doors N/A Main Garage Door Overhead / automatic Letterboxes Powder coated classic

Page 14: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Appendix D Reduced Architectural Drawings

Page 15: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Copyright URBAN LINK PTY LTD ©

NotesCONTRACTOR MUST VARIFY ALL DIMENSIONS ON SITE BEFORECOMMENCING WORK OR PREPARING SHOP DRAWINGS.DO NOT SCALE DRAWINGS.

Rev Description Date App'dProject

3 HOMEBUSH RD STRATHFIELDBOARDING HOUSE3 HOMEBUSH ROADSTRATHFIELD NSW 2135

Drawing Title

BASEMENT 01

Date of Issue18/04/2018

CheckedJE

ApprovedTJ

Scale

AS SHOWN@A1 Sheet Size

Project Number

2017 - 020Drawing Number

DA2001_ARevision

Status

PRELIMINARY

50mm on original

2017-020 3 Homebush Road, Strathfield - 180410(B).plnU:\Data\2017 Jobs\2017-020 3 Homebush Road, Strathfield\A Architectural\A.10 CAD\2017-020 3Homebush Road, Strathfield - 180410(B).pln18/04/20184:04 PM

Business Address: Level 10, 11-15 Deane Street, Burwood NSW 2134Postal Address: PO BOX 2223 Burwood North NSW 2134Phone Number: +61 29745 2014

A PRELIMINARY 10.02.17

1 2 3 4 5 6 7 8 9 10 11

3

3

2

2

B B

C C

A A

1

1

12

12

2

2

8,199

5,800

1,000 7,200 300 7,200 700 2,700 2,400 2,400 300 7,200 300 3,725

2,120 22,500

10,400

BOLLARD

CP 10W/ 09 MOTOCYCLES

09 BIKES1 DISABLE

SHAREDSPACE

1:46.0mM O T O C Y C L E

STORAGE

1:82.0m

1:82.0m

1:206.0m

BICYCLERACK

LIFT

8

8

7

7

6

6

5

5

4

4

9

9

10

10

BASEMENT 1:100

Page 16: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Copyright URBAN LINK PTY LTD ©

NotesCONTRACTOR MUST VARIFY ALL DIMENSIONS ON SITE BEFORECOMMENCING WORK OR PREPARING SHOP DRAWINGS.DO NOT SCALE DRAWINGS.

Rev Description Date App'dProject

3 HOMEBUSH RD STRATHFIELDBOARDING HOUSE3 HOMEBUSH ROADSTRATHFIELD NSW 2135

Drawing Title

GROUND FLOOR PLAN

Date of Issue18/04/2018

CheckedJE

ApprovedTJ

Scale

AS SHOWN@A1 Sheet Size

Project Number

2017 - 020Drawing Number

DA2003_ARevision

Status

PRELIMINARY

50mm on original

2017-020 3 Homebush Road, Strathfield - 180410(B).plnU:\Data\2017 Jobs\2017-020 3 Homebush Road, Strathfield\A Architectural\A.10 CAD\2017-020 3Homebush Road, Strathfield - 180410(B).pln18/04/20184:04 PM

Business Address: Level 10, 11-15 Deane Street, Burwood NSW 2134Postal Address: PO BOX 2223 Burwood North NSW 2134Phone Number: +61 29745 2014

A PRELIMINARY 10.02.17

26 m226 m2

22 m2

GF.0318 m2

24 m2

GF.0417 m2

24 m2

GF.0618 m2

24 m2

GF.0718 m2

21 m2

GF.0519 m2

27 m2

27 m2

29 m2

X1.0222 m2 GF.07

21 m2

GF.0718 m2

1 2 3 4 5 6 7 8 9 10 11

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

3

3

2

2

B B

C C

A A

1

1

12

12

2

2

3,524

6,726

3,000

4,500

4,500

3,000

3,000

9,000

3,000

901

3,000

4,000 6,000 2,500 3,800 3,800 3,800 3,800 3,800 3,770 2,530 16,831

3,000

9,000

3,000

2,997

9,000

3,000

2,997

9,000

3,000

4,000 6,000 2,500 3,800 3,800 3,800 3,800 3,800 3,770 2,530 7,025 9,806

3,000

1,800

7,200

3,000

7,580 3,800 3,800 4,200 2,525 3,800 3,800 3,800 3,800 3,800 6,697

2,997

1,800

7,200

3,000

2,997

9,000

3,000

2,997

9,000

3,000

3,000

9,000

3,000

1,035

1,530

1,035

1,550

13,400GF207 m2

12 m212 m222 m2

12 m212 m2

13 m2

12 m21:4

6.0m1:8

2.0m1:8

2.0m1:206.0m

COS

MAILBOXES

LIFT

820c820c

PROPOSEDDRIVEWAY

DOUBLE

COMMONLOUNGE

DOUBLE

DOUBLE

DOUBLE DOUBLE

DOUBLEDOUBLE

12 m2

F

F

8

8

7

7

6

6

5

5

4

4

9

9

10

10

POSPOSPOSPOSPOSPOSPOSPOS

F

F

F F FFW

/ D

R

W /

DR

W / DR

W /

DR

W /

DR

W /

DR

W /

DR

W / DR

BIN AREA

B I N

STO

RE

RO

BE

B I N

GROUND FLOOR 1:100

Page 17: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Copyright URBAN LINK PTY LTD ©

NotesCONTRACTOR MUST VARIFY ALL DIMENSIONS ON SITE BEFORECOMMENCING WORK OR PREPARING SHOP DRAWINGS.DO NOT SCALE DRAWINGS.

Rev Description Date App'dProject

3 HOMEBUSH RD STRATHFIELDBOARDING HOUSE3 HOMEBUSH ROADSTRATHFIELD NSW 2135

Drawing Title

LEVEL 01

Date of Issue18/04/2018

CheckedJE

ApprovedTJ

Scale

AS SHOWN@A1 Sheet Size

Project Number

2017 - 020Drawing Number

DA2004_ARevision

Status

PRELIMINARY

50mm on original

2017-020 3 Homebush Road, Strathfield - 180410(B).plnU:\Data\2017 Jobs\2017-020 3 Homebush Road, Strathfield\A Architectural\A.10 CAD\2017-020 3Homebush Road, Strathfield - 180410(B).pln18/04/20184:05 PM

Business Address: Level 10, 11-15 Deane Street, Burwood NSW 2134Postal Address: PO BOX 2223 Burwood North NSW 2134Phone Number: +61 29745 2014

A PRELIMINARY 10.02.17

27 m2

X1.0121 m2

29 m2

X1.0222 m2

24 m2

X1.0318 m2

24 m2 24 m2

X1.0618 m2

24 m2

X1.0718 m2 X1.08

16 m2

21 m2

X1.0519 m2

X1.0417 m2

24 m2

X1.0918 m2

2 m2

19 m2

X1.1024 m2

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

3

3

2

2

B B

C C

A A

1

1

12

12

2

2

3,000

1,800

7,200

3,000

2,997

9,000

3,000

2,997

9,000

3,000

2,997

9,000

3,000

3,000

9,000

3,000

1,035

1,530

1,035

1,550

L1-3253 m2

22 m2

LIFT

DOUBLE

DOUBLE

DOUBLE

DOUBLE

DOUBLE DOUBLEDOUBLE

DOUBLE

PRIVACY SCREENS PRIVACY SCREENS

F

F

F

F

8

8

7

7

6

6

5

5

4

4

9

9

10

10

F

F

FFW

/ D

R

W /

DR

W / DR

W /

DR

F FW

/ D

R

W /

DR

W / DR W / DR

W /

DR

W /

DR

B I N

STORE ROBE

B I N

STO

RE

RO

BE B I N

B I N

LEVEL 01 1:100

Page 18: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Copyright URBAN LINK PTY LTD ©

NotesCONTRACTOR MUST VARIFY ALL DIMENSIONS ON SITE BEFORECOMMENCING WORK OR PREPARING SHOP DRAWINGS.DO NOT SCALE DRAWINGS.

Rev Description Date App'dProject

3 HOMEBUSH RD STRATHFIELDBOARDING HOUSE3 HOMEBUSH ROADSTRATHFIELD NSW 2135

Drawing Title

LEVEL 02

Date of Issue18/04/2018

CheckedJE

ApprovedTJ

Scale

AS SHOWN@A1 Sheet Size

Project Number

2017 - 020Drawing Number

DA2005_ARevision

Status

PRELIMINARY

50mm on original

2017-020 3 Homebush Road, Strathfield - 180410(B).plnU:\Data\2017 Jobs\2017-020 3 Homebush Road, Strathfield\A Architectural\A.10 CAD\2017-020 3Homebush Road, Strathfield - 180410(B).pln18/04/20184:05 PM

Business Address: Level 10, 11-15 Deane Street, Burwood NSW 2134Postal Address: PO BOX 2223 Burwood North NSW 2134Phone Number: +61 29745 2014

A PRELIMINARY 10.02.17

19 m2

X1.1024 m2

24 m2

X1.0318 m2

24 m2 24 m2

X1.0618 m2

24 m2

X1.0718 m2 X1.08

18 m2

24 m2

X1.0918 m2

21 m2X1.0519 m2

X1.0417 m2

27 m2

29 m2

X1.0222 m2

2 m2

X1.0121 m2

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

3

3

2

2

B B

C C

A A

1

1

12

12

2

2

1DA4001

1DA4001

1DA4001

#DrgID#LayID

#DrgID#LayID

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1DA

3002

1DA

3002

1DA3001

1DA3001

1DA3001

1DA3001

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1DA

3002

1DA

3002

3,000

1,800

7,200

3,000

2,997

9,000

3,000

2,997

9,000

3,000

2,997

9,000

3,000

3,000

9,000

3,000

1,035

1,530

1,035

1,550

#Drg

ID#L

ayID

#Drg

ID#L

ayID

24 m2

L1-3254 m2

PRIVACY SCREENS PRIVACY SCREENS

DOUBLE

DOUBLE

F

F

FF

8

8

7

7

6

6

5

5

4

4

9

9

10

10

F

F

F F FFW

/ D

R

W /

DR

W / DR

W /

DR

W /

DR

W /

DR

W / DR

W /

DR

W /

DR

W / DR

B I N

STO

RE

RO

BE

B I N

B I N

STORE ROBE

LEVEL 02 1:100

Page 19: QUANTITY SURVEY REPORT · Exclusions ... projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls. It shall not include

Copyright URBAN LINK PTY LTD ©

NotesCONTRACTOR MUST VARIFY ALL DIMENSIONS ON SITE BEFORECOMMENCING WORK OR PREPARING SHOP DRAWINGS.DO NOT SCALE DRAWINGS.

Rev Description Date App'dProject

3 HOMEBUSH RD STRATHFIELDBOARDING HOUSE3 HOMEBUSH ROADSTRATHFIELD NSW 2135

Drawing Title

LEVEL 03

Date of Issue18/04/2018

CheckedJE

ApprovedTJ

Scale

AS SHOWN@A1 Sheet Size

Project Number

2017 - 020Drawing Number

DA2005_ARevision

Status

PRELIMINARY

50mm on original

2017-020 3 Homebush Road, Strathfield - 180410(B).plnU:\Data\2017 Jobs\2017-020 3 Homebush Road, Strathfield\A Architectural\A.10 CAD\2017-020 3Homebush Road, Strathfield - 180410(B).pln18/04/20184:05 PM

Business Address: Level 10, 11-15 Deane Street, Burwood NSW 2134Postal Address: PO BOX 2223 Burwood North NSW 2134Phone Number: +61 29745 2014

A PRELIMINARY 10.02.17

L1-3250 m2

X1.0230 m2

24 m2

X1.0518 m2

29 m2 27 m2

X1.0522 m2

24 m2

X1.0116 m2

X1.1025 m2

24 m2

X1.0918 m2

X1.0523 m2

21 m2

X1.1025 m2

2 m2

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

x 18

0 =

3,06

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

3

3

2

2

B B

C C

A A

1

1

12

12

2

2

1DA4001

1DA4001

1DA4001

#DrgID#LayID

#DrgID#LayID

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1DA

3002

1DA

3002

1DA3001

1DA3001

1DA3001

1DA3001

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1DA

3002

1DA

3002

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3,000

1,800

7,200

3,000

2,997

9,000

3,000

2,997

9,000

3,000

2,997

9,000

3,000

3,000

9,000

3,000

DOUBLE

DOUBLE

DOUBLE

DOUBLE

PRIVACY SCREENS PRIVACY SCREENS

22 m2

DOUBLE

DOUBLEDOUBLEDOUBLE

8

8

7

7

6

6

5

5

4

4

9

9

10

10

F

F F

F

F

FF

F

W / DR

W / DR

W /

DR

W /

DR

W / DR

W /

DR

W /

DR

W /

DR

B I N

STORE

B I N

STO

RE

ROBESTO

RE

B I N

RO

BE

STORE

B I N

RO

BE

STORE

B I N

RO

BE STORE

B I N

LEVEL 03 1:100