37
Quality by Design Approach for Determining Excipient Specifications for a Formulation M. Kallam, J. Farina, N. Deorkar Avantor Performance Materials, Inc.

Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Quality by Design Approach for Determining Excipient Specifications for a Formulation

M. Kallam, J. Farina, N. Deorkar Avantor Performance Materials, Inc.

Page 2: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Not All Materials are Created Equal and One Size Doesn’t Fit All

• Functionality and specifications depends on formulation • Different materials – different designs • Synergistic excipients – simplified designs • Customize QbD to your needs

2

Page 3: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Outline • Typical Formulation Development Practices • Concept of Quality by Design • Design of Experiments for QbD • Role of High-Functionality Excipients in QbD • Example of QbD application • Validations under QbD • Conclusions

3

Page 4: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

4

What works well for Pharma Industry? Which is better ??

Page 5: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Typical Formulation Practices

5

Define Target Quality Attributes

Ex: Round Tablet, Tablet Weight: NMT 350 mg Clear Embossing Dissolution: NLT 80% in 30 min Potency: 200 mg Hardness: NLT 80N and NMT 150N Assay: Within 95–110% of label claim Content Uniformity: NMT 5% RSD Stability: 6 month accelerated stability within ± 5% of initial results

Page 6: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Typical Formulation Practices

6

Alter composition or process

Scale up to pilot scale

Meets criteria

Yes

No

Test product

Literature search

Trial runs Components and process

Page 7: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Typical Formulation Practices

7

Alter composition or process

Scale up to production

Meets criteria

Yes

No

Test product Trial runs-Statistics

Pilot scale

Validate process

Write Master Batch Manufacturing Record

Page 8: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

8

Validated process

Formulation fixed at a specified composition

Process fixed at specified parameters

Any deviation from fixed values calls for investigation and holding batch until resolved or rejecting batch

Page 9: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

9

Advantages Disadvantages Fast to market Poor understanding of input and

response Lower developmental costs Many non-conforming incidents

(NCI) Lost time due to investigations of NCI’s Rejected batches Higher manufacturing costs in the long run Changing process requires regulatory approval

Typical Formulation Process

Page 10: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

10

Page 11: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Quality by Design

11

Define target quality attributes - same as before

Ex: Round Tablet, Tablet Weight: NMT 350 mg Clear Embossing Dissolution: NLT 80% in 30 min Potency: 200 mg Hardness: NLT 80N and NMT 150N Assay: Within 95–110% of label claim Content Uniformity: NMT 5% RSD Stability: 6 month accelerated stability within ± 5% of initial results

Page 12: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Quality by Design

12

Design experiments to study cause and effect relation

Literature search

Map the inputs that affect on CQA’s

Components and process

Propose design space from the results

Verify design space at pilot

scale

Scale up to production

Validate at extreme design space points

Page 13: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

13

Parameter Blend Time

Lubrica’n Time

Blender Fill %

Compr’n Force

Tablet Press Speed CQA

Assay Low Low Low Low Low

Stability Low Low Low Low Low

Content Uniformity

High Low High Low High

Hardness /Friability

Low Low Low High High

Embossing Low High Low High High

Dissolution Low High Low High High

QbD: Cause and Effect Mapping for Blending & Tableting Process

Page 14: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

14

Component API PSD Major Excipient PSD

Lubricant Major Excipient LOD

Other Functional Excipient CQA

Assay Low Low Low Low Low

Stability Moderate Low Moderate Moderate Moderate

Content Uniformity

High High Low Low Low

Hardness /friability

Low Low High Moderate Low

Embossing Low Low High High Low

Dissolution High Low High Low High

Page 15: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Use DOE to Determine Effects

DOE: • Full or factorial designs

or • Available standard

designs or • Custom defined

designs

After experiments: • Replicate each experiment

at least twice. • Analyze the data • Determine effects of each

factor • Develop contour plots • Overlay contour plots • Determine design space

15

Page 16: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Role of Co-Processed Excipients in QbD

• Simplifies the Design • One Input – Multiple Responses • Better Control Strategies – PAT • Low Process Variance • Risk Mitigation • Fast to Market

16

Page 17: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

17

Page 18: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Example:

• Objective: • Use QbD principles to determine API and excipient

specifications for formulating 200 mg ibuprofen tablets by direct compression.

• Target Quality attributes: • Tablet weight variation (Content Uniformity) less than

1% RSD at high press speeds • Hardness of 80–120 N • Dissolution of NLT 90% in 5 minutes • Defect free round bi-convex tablets

18

Page 19: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Materials

19

Material Manufacturer

J.T.Baker® PanExcea™MHC300G, an MCC based co-processed excipient

Avantor Performance Materials, Inc

Ibuprofen 40 and 70 grades Albemarle Corporation Silica (Rxcipients® GL-100) J.M. Huber Corporation Stearic acid (Hystrene®) PMC Biogenix, Inc Croscarmellose sodium (Vivasol®)

JRS Pharma GmbH

PanExcea™ is a trademark of Avantor Performance Materials, Inc Vivasol ® is a trademark of JRS PharmaGmbH Hystrene® is a trademark of PMC group RxCipients® is trademark of J.M. Huber Corporation

Page 20: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Factors • Evaluate Effect of the Following on CQA’s:

• API Particle Size • Excipient Particle Size • Excipient LOD

20

Levels • API Particle Size

• Two Levels – (D50 of 40 microns and 70 microns) • Excipient Particle Size

• Two Levels- (D50 of 95 microns and 145 microns) • Excipient LOD

• Two Levels- (LOD of 4.4 and 2.0)

Page 21: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Different Grades of Raw Materials

• May not always be available

• If available • Different Manufacturers • Different Processes • Different Methods

21

Page 22: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Different Grades of Excipient

22

PanExcea™ MHC300G 1400 grams

PanExcea™ MHC300G 700 grams

PanExcea™ MHC300G 700 grams

LOD 4.4, D50= 95 microns

PanExcea™ MHC300G 700 grams

LOD 2.0, D50= 95 microns

Dried for 30 minutes

Page 23: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Different Grades of Excipients

23

PanExcea™ MHC300G 2500 grams

PanExcea™ MHC300G 700 grams

LOD 4.4, D50=145 microns

PanExcea™ MHC300G 700 grams

LOD 2.0, D50=145 microns

Dried for 30 minutes

Sieved using #140 mesh

Discarded Pass through Blended for 10

minutes

Retained

Page 24: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Process

24

Preblend

Mill using Comil

Main Blending Lubricating Tableting

Page 25: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Full Factorial Design (3 factors, 2 levels)

25

StdOrder RunOrder CenterPt Blocks PSD Excipient PSD API LOD Excipient

7 1 1 1 95 70 4.4

5 2 1 1 95 40 4.4

6 3 1 1 145 40 4.4

8 4 1 1 145 70 4.4

1 5 1 1 95 40 2

4 6 1 1 145 70 2

3 7 1 1 95 70 2

2 8 1 1 145 40 2

Page 26: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Results

26

COD AOR Hardness Dis. time Dissoln at

5 min CU % RSD

2 36.9 92 33 98 0.9

6 39.3 82 25 90 1.3

4 39 118 38 97 1.1

2 36.4 94 36 100 0.4

3 39.8 100 37 85 1.1

2 35.6 88 28 84 1.1

3 37.7 89 32 94 1

3 38.1 95 35 84 1.8

COD: Critical Orifice Diameter AOR: Angle of Repose

Page 27: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Main Effects

27

Page 28: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Main Effects

28

Page 29: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Main Effects

29

Page 30: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Main Effects

30

Page 31: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Contour Plots

31

Page 32: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Design Space

32

Preferred working Space

Page 33: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Design Space

33

Design space for API D5040-70 microns

Preferred working space

Page 34: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Analysis- Design Space

34

Preffered working Space

Page 35: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Impact of Different Excipient Type • Design space comparison -

PanExcea™MHC300G and MCC – Poor responses with MCC at similar drug

loading – Unable to evaluate main and interaction

Effects – Unable to propose a design space

35

Page 36: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Process Validation under QbD • Design space must be validated at extremes • Validations at pilot scale or production scale • Process validations are extensive and costly • Advantages:

• Flexibility within design space • Allows in process control instruments (PAT’s) • Robust process • Deviation from batch record within design space • Less downtime for investigations • Less rejects and other wastes

36

Page 37: Quality by Design Approach for Determining Excipient ...avantor...Ex: Round Tablet, Tablet Weight: NMT 350 mg . Clear Embossing . Dissolution: NLT 80% in 30 min . Potency: 200 mg

Conclusions • QbD can be used to:

• Determine specifications for raw materials • Establish design space for

- Process parameters - Composition

• Develop control strategies to mitigate risks • Reduced quality control testing

37