Upload
duzzys
View
213
Download
0
Embed Size (px)
Citation preview
8/19/2019 Quad Close Trap Seal
1/2
REV.
E 11-6-12 Removedp TBW CLF 5-22-14 Revised Table, Notes TBW JMG 7-30-14 Added L/M TBW JMH 8-26-14 Revised Table TBW JM
DATE DESCRIPTION BY CKD. BY
WEIGHT
POUNDS
VOLUME
CUBIC FEETFIGURE NUMBER
LOCATION
F I G U R E
N U M B E R
D I M E N S I O N S A R E S U B J E C T T O M A
N U F A C T U R E R S T O L E R A N C E A N D C H A N G E W I T H O U T N O T I C E
W E C A N A S S U M E N O R E S P O N S I B I L I T Y F O R U S E O F S U P E R S E D E D O R V O I D D A
T A
D R A W N B Y :
C H E C K E D B Y :
A P P R O V E D B Y :
S C A L E :
D A T E :
S I Z E
A
D R A W I N G N
U M B E R
QUAD CLOSE® TRAP SEAL
2692
2 6 9 2
R N
C L
J M
G
5 - 2 0 - 0 8
N O N E
s 2 6 9 2
FUNCTION: The Quad Close Trap Seal forms a barrier to minimize the evaporation of the trap seal of a floor drain. TheQuad Close Trap Seal will open to allow drainage and close when there is no flow. It is for use in floor drain outlets orthe adjustable strainer throats.
NOTE: Dimensions shown inparentheses are in millimeters.
B
A DIA.
A IAPMO ASSE GPM FLOW FIG. NO. (Pipe Size) B LISTEDj LISTED j RATEl 2692-0150 01.5(38) 2.09(53) — — 6.0
(22.7 L/M)
2692-02 02(50) 2.66(68) FILE # 7479 REC.#1435 12.0
AF-GW n (45.4 L/M)
2692-03 03(75) 2.66(68) FILE # 7479 REC.#1435 34.0
AF-GW n (128.7 L/M)
2692-0350 0350(89) 2.66(68) FILE # 7479 REC.#1435 51.0
k k AF-GWn (193.06 L/M)
2692-04 04(100) 2.66(68) FILE # 7479 REC.#1435 73.0
AF-GW n (276.4 L/M)
2692-06 06(150) 3.66(93) — — 215.0
(814.0 L/M)
Patent No. 8,844,572
JAY R.
SMITH MFG. CO.®
MEMBER OF MORRIS GROUP INTERNATIONALPOST OFFICE BOX 3237MONTGOMERY, ALABAMA 36109-0237 (USA)TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com
CUSTOMER
DRIVEN
SMITH®
MEMBER OF:
®
ASPE®
SA N ITAR Y
E N G
I N E E R I N
GP r e v e n t i o n R athe r T h
a n C
u r e
SINCE 1926
INSTALLATION: The 01.5(38), 02(50), 03(75), 04(100) & 06(150) Quad Close Trap Seal sizes install in the drain outlet.To install, simply insert the Quad Close Trap Seal in the drain outlet or k throat of strainer until the top of it is flush withtop of drain outlet or strainer throat. See reverse side of submittal for illustration.
NOTES:
j Tested by The IAPMO R&T Product Certification Agency to ASSE Standard #1072, Barrier Type Floor Drain Trap Seal Protection Devices. All sections of the Standard was successfully
passed.k The 0350 (89) Quad Close Trap seal size installs in the throat of Smith adjustable strainers. See reverse side of submittal for illustration.l Required flow rates per ASSE Standard #1072, Section I. All sizes meets or exceeds these flow rates.m Do not use in applications where the room/space has an atmospheric pressure less than the ambient pressure of the exterior of the room/space or building.n AF-GW represents floor designation/rated for all floor types per ASSE 1072, Section II.o Copies of the listing certificates and/or ASSE 1072 Test Report available upon request.
8/19/2019 Quad Close Trap Seal
2/2
REV.
A 2-10-10 Revised Drawing RN BWB 4-2-12 Added Note TBW DP
DATE DESCRIPTION BY CKD. BY
WEIGHT
POUNDS
VOLUME
CUBIC FEETFIGURE NUMBER
LOCATION
F I G U R E
N U M B E R
D I M E N S I O N S A R E S U B J E C T T O M A
N U F A C T U R E R S T O L E R A N C E A N D C H A N G E W I T H O U T N O T I C E
W E C A N A S S U M E N O R E S P O N S I B I L I T Y F O R U S E O F S U P E R S E D E D O R V O I D D A
T A
D R A W N B Y :
C H E C K E D B Y :
A P P R O V E D B Y :
S C A L E :
D A T E :
S I Z E
A
D R A W I N G N
U M B E R
QUAD CLOSE® TRAP SEAL
2692 BS
2 6 9 2 B S
R N
C L
J M
D
5 - 2 0 - 0 8
N O N E
s 2 6 9 2 B S
INSTALLATION: The 0150(38), 02(50), 03(75), 04(100) & 06(150) Quad Close Trap Seal sizes install in the drainoutlet. The 0350(89) Quad Close Trap Seal size installs in the throat of adjustable strainers. To install simply inserthe Quad Close Trap Seal in the drain outlet or throat of strainer until the top of it is flush with top of drain outlet orstrainer throat.
Installation Illustrations
Installation in DrainBody Outlet
0150(38), 02(50), 03(75), 04(100) & 06(150) Sizes
Installation in StrainerThroat k
0350(89) Size
C 4-24-12 Rev. Title, Installation TBW CLD 8-26-14 Revised Installation TBW JM
JAY R.
SMITH MFG. CO.®
MEMBER OF MORRIS GROUP INTERNATIONAL
POST OFFICE BOX 3237MONTGOMERY, ALABAMA 36109-0237 (USA)TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com
CUSTOMER
DRIVEN
SMITH®
MEMBER OF:
®
ASPE®
SA N ITAR Y
E N G
I N E E R I N
GP r e v e n t i o n R athe r T h
a n C u
r e
SINCE 1926