16
Q500-P10 performance report Version 0.2 Nov 2013

Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Q500-P10 performance report

Version 0.2

Nov 2013

Page 2: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

3

Table of Contents

Revision History ............................................................................................ 2

Table of Contents ........................................................................................... 3

1. Test bed ............................................................................................. 4

1.1 Hardware ........................................................................................ 4

1.2 Software ......................................................................................... 4

1.3 Storage target settings ..................................................................... 5

2. Test matrix ......................................................................................... 6

3. Single controller - Sequential ................................................................ 7

3.1 RAID 0 ............................................................................................ 7

3.2 RAID 5 ............................................................................................ 8

3.2.1 RAID 5 degrade ............................................................................ 8

3.2.2 RAID 5 rebuild .............................................................................. 9

3.2.3 RAID 5 comparison ...................................................................... 10

3.3 RAID 6 ........................................................................................... 11

3.3.1 RAID 6 degrade ........................................................................... 12

3.3.2 RAID 6 rebuild ............................................................................. 13

3.3.3 RAID 6 comparison ...................................................................... 14

4. Dual controllers – Sequential ............................................................... 15

4.1 RAID 0 ........................................................................................... 15

4.2 RAID 5 ........................................................................................... 15

4.3 RAID 6 ........................................................................................... 16

Page 3: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

4

1. Test bed

The testing environment includes host servers, HBA cards, HDDs, and switches.

All performance cases conducted here are on Windows platform. There are no

Linux, Unix, or Mac platform numbers. Details are listed below.

1.1 Hardware

Host servers

There are total 4 servers. Three are ASUS RS700-X7/PS4. One is ASUS

TS500-E6-PS4

Model name ASUS RS700-X7/PS4

Processor(s) CPU:Intel® Xeon® E5-2620 2.00GHz

Memory ASUS 8GB PC3-10600 (REG, ECC) with ELPIDA

On-board LAN Intel® 82574L Gigabit Network Connection

Model name ASUS TS500-E6-PS4

Processor(s) CPU:Intel® Xeon® E5520 2.27GHz

Memory ASUS 2GB PC3-10600 (REG, ECC) with ELPIDA

On-board LAN Intel® 82574L Gigabit Network Connection

iSCSI HBA cards

Device name Intel® 82574L Gigabit Network

Driver version 12.7.27.0

Hard drives

Seagate Cheetah 3.5” SAS 15K.5 ST373455SS 73GB x24

1GbE switch

Dell PowerConnect 5324

1.2 Software

Operating system used on host servers.

Windows Server 2008 R2 Enterprise 64bit with service pack 2

Page 4: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

5

Benchmark tools

o Iometer 2006,07,27

o IOmeter settings

Cache hit : max disk size = 20480

None cache hit : max disk size = 0

# of outstanding I/Os : 64

Ramp up time : 5 seconds

Run time : 25 seconds

1.3 Storage target settings

RAID controller : Dual controller Q500-P10-D424

Firmware version : 1.0.0_ 20130425_1600

Host interfaces :

o Single controller : up to 6x 1GbE iSCSI ports

o Dual controller : up to 12x 1GbE iSCSI ports

Stripe height (KBytes): 64KB

Block size : 512 Bytes

Write back or write through : Write back

Best configuration suggestion

As a general rule of thumb, try to assign dedicated RAID group (RG) to each host

interface port. This will yield the best performance. If you assign each RG to

several host interface ports, this usually will result in not so good performance.

Page 5: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

6

2. Test matrix

The following is the test configuration used in this report.

Sequential Random

RAID 0 O(single/dual) X

RAID 5 O(single/dual) X

Degrade O(single) X

Rebuild O(single) X

RAID 6 O(single/dual) X

Degrade O(single) X

Rebuild O(single) X

Page 6: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

7

3. Single controller - Sequential

3.1 RAID 0

Configurations

Host servers : Three servers

# of host interface : 6x 1GbE iSCSI with 1x trunking

6x RGs. Each RG has one VD. Each RG has 4x HDDs.

RAID 0 sequential read/write

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 133295.8 78796.7 21053.4 2630.5 559.0

NCH 123557.9 75666.0 20654.9 2453.3 645.5

Throughput (MBytes/sec)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 65.1 307.8 657.9 657.6 559.0

NCH 60.3 295.6 645.5 613.3 645.5

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 91490.1 70761.1 15770.3 2221.8

NCH 90520.7 63152.6 14011.8 2021.1 505.7

Throughput (Mbytes/sec)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 44.7 276.4 492.8 555.4

NCH 44.2 246.7 437.9 505.3 505.7

Page 7: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

8

3.2 RAID 5

Configurations

Host servers : One server

# of host interface : 6x 1GbE iSCSI with MPIO

1x RGs. Each RG has one VD. Each RG has 8x HDDs.

RAID 5 sequential read/write

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 127703.7 95397.7 20712.9 2673.0 664.5

NCH 129204.8 98229.9 20560.1 2680.4 666.5

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 62.4 372.6 647.3 668.2 664.5

NCH 63.1 383.7 642.5 670.1 666.5

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 104520.7 78550.0 15016.6 2117.1 502.0

NCH 93927.5 71987.9 15020.3 2056.2 513.4

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 51.0 306.8 469.3 529.3 502.0

NCH 45.9 281.2 469.4 514.0 513.4

3.2.1 RAID 5 degrade

Configurations

Host servers : Two servers

# of host interface : 2x 1GbE iSCSI

2x RGs. Each RG has one VD. Each RG has 8x HDDs.

Unplug one HDD to make RAID 5 in degraded mode

Page 8: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

9

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 124833.6 36007.2 7144.5 892.3 221.7

NCH 133293.5 35966.5 7013.0 836.8 220.2

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 61.0 140.7 223.3 223.1 221.7

NCH 65.1 140.5 219.2 209.2 220.2

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 93822.6 56717.4 7079.5 874.9 217.9

NCH 96605.9 56181.9 7071.6 874.5 217.7

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 45.8 221.6 221.2 218.7 217.9

NCH 47.2 219.5 221.0 218.6 217.7

3.2.2 RAID 5 rebuild

Configurations

Host servers : Two servers

# of host interface : 2x 1GbE iSCSI

2x RGs. Each RG has one VD. Each RG has 8x HDDs.

Plug in one new HDD to rebuild RAID 5 parity

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 34148.7 22086.0 7102.1 891.8 222.5

NCH 35087.3 27225.7 7070.3 890.0 219.6

Page 9: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

10

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 16.7 86.3 221.9 222.9 222.5

NCH 17.1 106.4 220.9 222.5 219.6

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 28283.7 23945.9 6595.9 860.7 214.4

NCH 28684.6 28409.7 6720.1 864.1 213.6

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 13.8 93.5 206.1 215.2 214.4

NCH 14.0 111.0 210.0 216.0 213.6

3.2.3 RAID 5 comparison

We compare RAID 5 performance under the same configuration to show the

degrade and rebuild impact on performance. None cache hit numbers are

used here.

Page 10: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

11

3.3 RAID 6

Configurations

Host servers : One server

# of host interface : 6x 1GbE iSCSI with MPIO

1x RGs. Each RG has one VD. Each RG has 8x HDDs.

RAID 6 sequential read/write

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 114631.4 94976.3 20475.2 2672.6 668.0

NCH 126333.8 91047.5 20307.7 2679.3 666.3

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 56.0 371.0 639.8 668.2 668.0

NCH 61.7 355.7 634.6 669.8 666.3

Page 11: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

12

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 95987.3 74206.7 15578.3 2132.9 534.4

NCH 99395.6 65647.3 14541.2 2028.3 507.5

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 46.9 289.9 486.8 533.2 534.4

NCH 48.5 256.4 454.4 507.1 507.5

3.3.1 RAID 6 degrade

Configurations

Host servers : Two servers

# of host interface : 2x 1GbE iSCSI

2x RGs. Each RG has one VD. Each RG has 8x HDDs.

Unplug two HDDs to make RAID 6 in degraded mode

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 120386.7 36093.7 7142.6 880.9 216.1

NCH 125569.6 36295.9 7144.4 889.8 220.3

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 58.8 141.0 223.2 220.2 216.1

NCH 61.3 141.8 223.3 222.4 220.3

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 97770.4 56069.2 7080.4 875.3 217.6

NCH 98512.0 49827.1 7008.1 873.6 217.3

Page 12: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

13

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 47.7 219.0 221.3 218.8 217.6

NCH 48.1 194.6 219.0 218.4 217.3

3.3.2 RAID 6 rebuild

Configurations

Host servers : Two servers

# of host interface : 2x 1GbE iSCSI

2x RGs. Each RG has one VD. Each RG has 8x HDDs.

Plug in two HDDs to rebuild RAID 6 parity

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 29588.7 20384.0 7089.1 892.0 221.7

NCH 30287.4 21802.5 7030.2 890.1 220.4

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 14.4 79.6 221.5 223.0 221.7

NCH 14.8 85.2 219.7 222.5 220.4

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 29106.2 21617.7 6412.0 850.7 212.1

NCH 28665.1 28560.2 6644.9 855.8 210.4

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 14.2 84.4 200.4 212.7 212.1

NCH 14.0 111.6 207.7 214.0 210.4

Page 13: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

14

3.3.3 RAID 6 comparison

We compare RAID 6 performance under the same configuration to show the

degrade and rebuild impact on performance. None cache hit numbers are

used here.

Page 14: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

15

4. Dual controllers – Sequential

4.1 RAID 0

Configurations

Host servers : Two servers

# of host interface : 12x 1GbE iSCSI with 2x trunking

2x RGs. Each RG has one VD. Each RG has 8x HDDs.

RAID 0 sequential read/write

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 259438.2 205735.2 41639.0 5353.6 1338.6

NCH 253559.4 203223.5 41028.2 5363.9 1335.2

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 126.7 803.7 1301.2 1338.4 1338.6

NCH 123.8 793.8 1282.1 1341.0 1335.2

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 193064.6 149871.2 29322.3 4196.5 1048.8

NCH 196886.4 144702.3 29585.6 4144.8 1022.0

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 94.3 585.4 916.3 1049.1 1048.8

NCH 96.1 565.2 924.5 1036.2 1022.0

4.2 RAID 5

Configurations

Host servers : Two servers

# of host interface : 12x 1GbE iSCSI with 2x trunking

2x RGs. Each RG has one VD. Each RG has 8x HDDs.

RAID 5 sequential read/write

Page 15: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

16

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 249418.2 195637.1 41517.0 5353.5 1335.6

NCH 239356.4 196022.5 38042.6 5360.7 1335.0

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 121.8 764.2 1297.4 1338.4 1335.6

NCH 116.9 765.7 1188.8 1340.2 1335.0

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 181165.7 142753.1 29064.4 4150.2 1042.0

NCH 186481.6 137599.9 27628.7 3963.9 985.6

Throughput (Mbytes/s)

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 88.5 557.6 908.3 1037.5 1042.0

NCH 91.1 537.5 863.4 991.0 985.6

4.3 RAID 6

Configurations

Host servers : Two servers

# of host interface : 12x 1GbE iSCSI with two MPIO

2x RGs. Each RG has one VD. Each RG has 12x HDDs.

RAID 6 sequential read/write

IOPS

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 252807.8 203599.9 42100.8 5356.7 1339.1

NCH 255892.2 198319.8 41965.5 5338.9 1334.8

Page 16: Q500-P10 performance report - epasystemy.com.pl fileCopyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved. Qsan Document 4 1. Test bed The testing environment includes host

Copyright © 2004-2013 Qsan Technology, Inc. All Rights Reserved.

Qsan Document

17

Throughput (Mbytes/s)

512B; Read 4K; Read 32K; Read 256K; Read 1M; Read

CH 123.4 795.3 1315.7 1339.2 1339.1

NCH 124.9 774.7 1311.4 1334.7 1334.8

IOPS

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 194989.8 153263.7 29696.2 4193.8 1051.3

NCH 189627.2 139859.7 28734.3 3951.7 984.7

Throughput

512B; Write 4K; Write 32K; Write 256K; Write 1M; Write

CH 95.2 598.7 928.0 1048.4 1051.3