IMPORTANT SAFEGUARDS READ CAREFULLY AND FOLLOW ALL SAFETY INSTRUCTIONS. When using electrical equipment, basic safety precautions should always be followed including the following: DISCONNECT AC POWER SUPPLY BEFORE SERVICING. Installation and servicing of this equipment should be performed by qualified service personnel only. Ensure the electrical connections conform to the National Electrical Code NEC® and local regulations, if applicable. Do not mount near gas or electrical heaters. Do not use outdoors. Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any modification or use of non-original components will void the warranty and product liability. Do not use this equipment for other than intended use. Do not pull the cord to unplug the unit, pull on the plug only. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. SAVE THESE INSTRUCTIONS! PWM Remote Controller Installation Instructions 40070032 REV 1 10/20 1 800-533-3948 www.barronltg.com

PWM Remote Controller · IR Remote Controls Use the included IR remote to adjust all controller settings. (Fig. 4) Fig. 4 Local Time Brightness -10% Customization On/Off Brightness

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • IMPORTANT SAFEGUARDSREAD CAREFULLY AND FOLLOW ALL SAFETY

    INSTRUCTIONS.When using electrical equipment, basic safety precautions should always be followed including the following:• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.• Installation and servicing of this equipment should be performed by qualified service personnel only.• Ensure the electrical connections conform to the National Electrical Code NEC® and local regulations, if applicable.• Do not mount near gas or electrical heaters.• Do not use outdoors.• Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. • Any modification or use of non-original components will void the warranty and product liability.• Do not use this equipment for other than intended use.• Do not pull the cord to unplug the unit, pull on the plug only.• THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

    SAVE THESE INSTRUCTIONS!

    PWM Remote ControllerInstallation Instructions

    40070032 REV 1 10/20 1 800-533-3948 www.barronltg.com

  • Fig. 3 - Home Screen

    Electrical Connections1. Connect the dimmer output from the controller to the dimming input of the Varius bar with the included cable. (Fig. 1)

    a. If connecting to more than one bar (up to 8 total), we recommend using the AG-8-DIM-H accessory daisy chain cable to connect each bar to the controller. Connect it to the dimming input port of each bar. (Fig. 2)

    2. Connect the DC adapter (included) to the 12V input port of the controller.

    3. Turn the power on and check that the controller boots up. The unit will display the home screen, which displays the environment temperature (TEM), local time (T), and current brightness setting (CHA - Channel A). (Fig. 3)

    Note: If you would like to use this dimmer with a different brand of fixture, the end of the dimming cable can be cut off and the wires stripped back to expose the purple and grey wires inside. These can then be spliced to the dimming input of any 0-10V dimmable fixture. Purple is positive (+) and grey is negative (-).

    Fig. 2

    AG-8-DIM-H

    PWM Controller

    Fig. 1

    PWM Controller

    Varius Bar

    PWM Remote ControllerInstallation Instructions

    40070032 REV 1 10/20 2 800-533-3948 www.barronltg.com

  • IR Remote ControlsUse the included IR remote to adjust all controller settings. (Fig. 4)

    Fig. 4

    Local Time

    Brightness -10%

    Customization

    On/Off

    Brightness +10%

    Preset

    Channel ABrightness +/-1%

    PWM Remote ControllerInstallation Instructions

    40070032 REV 1 10/20 3 800-533-3948 www.barronltg.com

  • Fig. 5 - Time Setup ScreenController SetupSetting the Current Time1. Press the “TIME” button on the remote.

    2. Press “OK” to enter setup. (Fig. 5)

    3. Set the displayed time to the current time. • Use up and down to toggle between hour and minute adjustment. • Use “+” and “-” to increase or decrease the number displayed, respectively. Note: Time is displayed in 24-hour format.

    4. Press “OK” to save the current time.

    Using the Factory Preset SchedulesThe controller comes with two sample preset schedules that can be used instead of custom schedules for ease of use.1. Press the “PRE” button on the remote.

    2. Press “OK” to enter the preset selection screen. (Fig. 6)

    3. Use the up and down arrow keys to select either Preset 1 or Preset 2 (flashing).

    The default values of the presets are shown below. These values cannot be modified.

    4. Press “OK” to select and run the desired preset. The home screen should now display the selected preset. (Fig. 7)

    SET1SET2SET3SET4SET5SET6SET7SET8SET9SET10SET11SET12

    BRT Time05:0005:3006:0006:3007:3009:3016:3017:3018:3019:0019:3020:00

    CH-APRESET 2

    10%20%30%50%80%100%80%50%30%20%10%0%

    Fig. 6 - Preset Selection Screen

    Fig. 7 - Updated Home ScreenSET1SET2SET3SET4SET5SET6SET7SET8SET9SET10SET11SET12

    BRT Time06:0006:3007:0007:3008:0009:0015:0016:0017:0017:3018:0019:00

    CH-APRESET 1

    10%20%30%50%80%

    100%80%50%30%20%10%0%

    PWM Remote ControllerInstallation Instructions

    40070032 REV 1 10/20 4 800-533-3948 www.barronltg.com

  • Setting a Custom Timing ScheduleThe system can be configured with two (2) custom timing schedules, Custom1 and Custom2.1. Press the “CUS” (custom) button on the remote.

    2. Press the “OK” button on the remote to select custom scheduling. (Fig. 8)

    3. Use the up and down arrow buttons to toggle between Custom1 and Custom2, then press “OK” to select the schedule you would like to modify (flashing) and enter the schedule setting screen. (Fig. 9) Note: Pressing “Back” will exit and cancel the custom setting then return to the main interface.

    4. Press “OK” again and the SET1 time will begin flashing. • Use the up, down, left, and right arrow buttons to select the field you want to modify. • Use “+” and “-” to increase or decrease the number displayed, respectively. Note: The brightness (BRT) can be set between 0 and 100%. Time is in 24-hour format and must be set with a minimum of 1 minute between events.

    Example Custom Schedule:

    5. When you are done creating your custom schedule, press “OK” to save and run the configuration. The controller should now display the name of the custom schedule. (Fig. 10)

    Fig. 8 - Custom Schedules Screen

    Fig. 9 - Schedule Setting Screen

    SET1SET2SET3SET4SET5SET6SET7SET8

    BRT Time10%50%80%100%90%80%70%60%

    06:0007:0008:0008:3016:3017:0017:3018:00

    CH-A

    Fig. 10 - Updated Home Screen

    PWM Remote ControllerInstallation Instructions