15
© 2021 MEAN WELL All rights reserved All rights reserved by MEAN WELL 2021 PWM - 200 KN Series Product Manger MEAN WELL Product Strategy Center Wen Wu [email protected] 200W PWM Output KNX LED driver

PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

All rights reserved by MEAN WELL 2021

PWM-200KN SeriesProduct Manger | MEAN WELL Product Strategy CenterWen Wu | [email protected]

200W PWM Output KNX LED driver

Page 2: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

• 200W Constant Voltage PWM style output

• KNX with Data Secure protocol, no need KNX-DALI gateway

• Constant light output, support in ETS

• Min. dimming level 0.01%

• PWM output frequency 4K Hz compliant to IEEE 1789-2015 no risk

flickering & New ErP SVM requirement

• Meet SELV and class II design without FG

• Built-in software Over Temperature Protection

PWM-200KN Series: Key Features

2

Page 3: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

• KNX direct constant voltage (CV) LED driver,no need DALI gateway

KNX Single Output LED Driver

AC/DC LED driverKNX dimming actuatoror

DALI gateway

3 in 1

+

KNX + AC/DC LED driver(CV)

3

Page 4: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved 4

What is KNX Data Secure?

What is the security level used in KNX Data Secure?

Based on ISO 18033-3 standardized security algorithm, AES 128-bit encryption.

AES encryption is commonly used in Wi-Fi router router->

Additional information: Other communications of MW products such as DALI, PMBus, CANBus are not encrypted

KNX Data Secure signs and encrypts the communication telegrams in the KNX bus network to avoid unauthorized access or manipulation.Therefore, KNX Secure products can prevent hacker attack scenarios, such as communication content (sniffing), repeated communication (replay attack) or tampering (man in the middle attack).

Page 5: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved 5

What is Device certificate?

Device certificate is a 36-character string. The purpose is to enable Data Secure on ETS for the first time. Therefore, ETS will first read the device certificate and use the built-in camera of the laptop to read the QR code (no need to type) and import to ETS

The device certificate is an easy-to-remove label placed on the front of the device. After installation, the label must be removed from the device and stored safely to prevent unauthorized personnel from obtaining it to avoid information security crisis

Page 6: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved 6

Can PWM-200KN only be installed in a full Secure system?

No, in addition to being installed in all new installation systems that use Data Secure, it can also be used in an installed traditional KNX system for upgrading.

Page 7: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved 7

Is it possible to disable the secure function for PWM-200KN?Yes, user only need to set the secure commissioning to “Deactivated” in the ETS application database of and the device with KNX Data Secure will be configured just like a traditional KNX device. The behavior is the same as that of devices without KNX Data Secure, which means that KNX Data Secure devices can also be used in existing systems, such as replacing damaged devices.

Page 8: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved 8

KNX LED driver programming button position comparison

PWM-200KNProgramming button is on the sideNo need to disassemble the power supply when re-addressing is requiredMore convenient to use

PWM-60/120KN is at the bottom

Red LED indicator Programing button

Page 9: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

• The lowest dimming level can reach 0.01%,

suitable for applications that requires low

light level environments, such as cinema

• Min. dm level 0.01% => 1% Perceived light

Min. dim level 0.01%

9

Page 10: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

• According to IEEE 1789-2015,

frequency should be high to

avoid no risk flickering

• Output frequency is 4K Hz

3000

PWM-200KN

Frequency (Hz)

10001001%

10%

100%

Perc

ent F

licke

r or F

licke

r fac

tor (

%r

PWM-200 meets IEEE 1789-2015 (No Flicker Risk)

10

Page 11: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

• Output power is increased to compensate the lumen

reduction over time

• To ensure constant light intensity over time

• The decay of LED light is resolved, achieving energy saving

Constant light output (CLO)

Without CLO CLO

Power PowerLumen

Operating time Operating time

Lumen

Energy saving

11

Page 12: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

Built-in software OTP• Lamp overheating protection can be set through software,

and the protection temperature can be adjusted according to

different lamp designs to ensure the safety inside the building

12

Page 13: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

Control and feedback functions• The unit is built-in, operating time statistics, power consumption

feedback, lamp short circuit feedback

• Linear/logarithmic curve selection for various application scenarios

Linear curve, suitable for special lighting control applications

Logarithmic curve, close to human vision, providing comfortable dimming experience

DALI curve , same dimming experience as DALI protocol

13

Page 14: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

Hotel lighting Household Lighting Retail lighting Decorative lighting

• LED strip lighting

• Indoor lighting

• LED strip lighting

• Indoor lighting

• LED strip lighting

• Ambient lighting

• LED strip lighting

• Indoor lighting

PMW-KN Series Applications

14

Page 15: PWM-200KN Series• According to IEEE 1789-2015, frequency should be high to avoid no risk flickering • Output frequency is 4K Hz 3000 PWM-200KN Frequency (Hz) 100 1000 1% 10% 100%

© 2021 MEAN WELL All rights reserved

P

Q

C

D

S

R

ProductsMore than10,000 models, continues to introduce 10% new models and EOL 5% every year

QualityHigh reliability and quality indicatorPost-sales failure rate decreases by 10% each year

CostHigh cost-performance products, stable material price, complete supply chain integration

Delivery24-hour delivery for small amount order.14-day delivery for frequent purchase standard products.

ServiceMEAN WELL Group and distributors provide services 24 hours a day, and commit to reply within 24 hours

Reliable Relationship75% of revenue come from long-term distributors and customers

WHY MEAN WELL

15