18
Electric Blowers Fans/Blowers Environmental Equipment Dust Collectors Catalog No. A4-13-02E Published August 2012 Comprehensive Catalog of Blowers Safety Precautions Before using your product, carefully read the Operating Instruction Manual for a thorough understanding of the proper product usage. The contents of this catalog presuppose transactions and use in Japan only. Business Items Electric Blowers Providing Hospitality to the Environment Low-noise series High-pressure series Multi-stage series All-purpose series General-purpose series Flange-installed series Stainless-steel series Explosion-proof series Large-sized series Denchoku High-pressure vortex series blowers Gust Blower Agitating/circulating series (Double Volute) Fans/Blowers Turbofans Delturbo Turbo blowers Airfoil fans Sirocco fans Plate fans Axial flow fans with variable blade pitch Kairyu Environmental Equipment Mist collectors Mistresa Portable fans Wind Bag Dust Collectors Dustresa • Compact series • Small-sized pulse jet series • Moveable open-type series • Pulse jet series Fumeresa *The contents of this catalog are subject to change without prior written notice. Visit our Website to view the latest version of the catalog. *We are currently delivering CAD data through the Website. For environment protection, this catalog is printed on recycled paper using soybean oil ink. Head office: 1-25 Shinden Kitamachi, Daito City, Osaka 574-0052 Japan Founded: June 29, 1950 Sales: 6.6 billion yen (achievements in fiscal 2011) E-mail: [email protected] The main award histories: Awarded minister of economy in 2006 <IT management promotion section> Distributor locations: Thailand, Brazil, China, France, Germany, India, Indonesia, Korea, Malaysia, Philippines, The U.K., The U.S.A., Vietnam etc... Distributor

Published August 2012 Comprehensive Electric Blowers Fans

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Electric Blowers Fans/Blowers Environmental Equipment Dust Collectors

Catalog No. A4-13-02EPublished August 2012

Comprehensive Catalog of Blowers

Safety Precautions

Before using your product, carefully read the Operating Instruction Manual

for a thorough understanding of the proper product usage.

The contents of this catalog presuppose transactions and use in Japan only.

Business Items

Electric Blowers

Providing Hospitality to the Environment

Low-noise seriesHigh-pressure seriesMulti-stage seriesAll-purpose seriesGeneral-purpose seriesFlange-installed seriesStainless-steel seriesExplosion-proof seriesLarge-sized seriesDenchokuHigh-pressure vortex series blowersGust BlowerAgitating/circulating series(Double Volute)

Fans/BlowersTurbofansDelturboTurbo blowersAirfoil fansSirocco fansPlate fansAxial flow fans with variable blade pitchKairyu

Environmental EquipmentMist collectors MistresaPortable fansWind Bag

Dust CollectorsDustresa• Compact series• Small-sized pulse jet series• Moveable open-type series• Pulse jet seriesFumeresa

*The contents of this catalog are subject to change without prior written notice.Visit our Website to view the latest version of the catalog.

*We are currently delivering CAD data through the Website.

For environment protection, this catalog is printed on recycled paper using soybean oil ink.

Head office: 1-25 Shinden Kitamachi, Daito City, Osaka 574-0052 JapanFounded: June 29, 1950Sales: 6.6 billion yen (achievements in fiscal 2011)E-mail: [email protected] main award histories: Awarded minister of economy in 2006

<IT management promotion section>Distributor locations: Thailand, Brazil, China, France, Germany, India, Indonesia, Korea, Malaysia,

Philippines, The U.K., The U.S.A., Vietnam etc...

Distributor

1 2

http://www.showadenki.co.jp

You can download performance curve sheets and dimensional outline drawings from our Website. Here is the procedure:

Conditional search

1. Click the Search button on the first page of the window.

2. Select one of two search methods:

You can search for a product by specifying its model.

This function allows you to search for a product by specifying the appropriate product group and specifications/requirements.

1

Enter one-byte alphameric characters into the Air Volume/Static Pressure field (mandatory).Next, click the Search button.

The corresponding products will be displayed.A click of the button will display detailed product information.

Enter the model.

Pressing the button corresponding to necessary material will allow you to download the material.

Pressing the button corresponding to necessary material will allow you to download the material.

Notes:- If the desired material is not downloaded by

the click, select [Save target in file] by right-clicking to save the material.

- You need to use the appropriate CAD software (dfx file) to view CAD data.

Notes:- If the desired material is not downloaded by

the click, select [Save target in file] by right-clicking to save the material.

- You need to use the appropriate CAD software (dfx file) to view CAD data.

Clicking the button on the detailed product information display window will change window control to the following window:

Clicking the button on the detailed product information display window will change window control to the window shown at right.

Model search2

The corresponding products will be displayed.A click of the button will display detailed product information.

Download Material from the Website

Catalog Download

Click the Catalog Download button on the first page of the window.

Pressing the button corresponding to necessary material will allow you to download the material.

Blower Perform

ance Curve Sheet

A1D (Axial �ow fan) 50HzA1D (Axial �ow fan) 60HzA2D (Axial �ow fan) 50HzA2D (Axial �ow fan) 60Hz

P.19P.20P.19P.20

KT (Airfoil fan)M1V (Sirocco fan)P1V (Plate fan)GP (Plate fan)

P.11P.13P.15P.17

T1V (Turbo fan)T2V (Turbo fan)B2V (Turbo blower)B3V (Turbo blower)

P.5P.7P.9P.10

A1V (Axial �ow fan)A2V (Axial �ow fan)CM (Agitating fan)CA (Agitating fan)Electric blowerDenchoku

P.21P.21P.23P.24P.25P.27

3 4

Blower Performance Curve Sheet

B2

GP

T1V

T2V

P1

A2D(60Hz)

A2D(50Hz)

M1V

KT

A1D(50Hz)

A1D(60Hz)

B3

10.09.08.0

7.0

6.0

5.0

4.0

3.0

2.0

1.5

1.25

1.00.90.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Static pressure (kPa)

1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 7080 90100 125 150 200 300 400 500600700800900 1500 20001000 1750 2250

900070005000300010000800060004000

Air volume (m³/min)

Turbo Fan T1V

5 6

T1V-Type Turbo Fan Delturbo with V-Belt Drive

40

36

3228

24

22

2018

16

14

12

10

08Nominal number

� Type T1V⓪⑧ (Nominal number)

� Uses Dust remover and collectorHot blast circulatorDryerIncinerator

Smoke exhaust apparatusCombustion apparatusBoilerFood/chemicals related equipment

Air blower/exhaust apparatus for various plant equipmentMiscellaneous

4.03.83.53.23.0

2.5

2.2

2.0

1.8

1.5

1.2

1.0

0.8

0.6

0.5

0.4

0.3

0.2

0.1

10 20 40 60 80 100 120 150 200 250 300 400 500 600 800 1000 1200 1500 20002200

Air volume (m³/min)

Features

A low-pressure high-capacity type. With a multi-purpose impeller applicable to collecting a small amount of dust as well.Actual applicability depends on the quality and amount of dust. Please contact us for further details.

Static pressure (kPa)

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Turbo Fan T2V

T2V08 kW ※ p

※ m3/min V

※ kPa kW

2225 min-1

90

80

70 1

60

0.8

1.2 0.6

0.8 0.4

0.4 0.2

0 0 0

0 10 20 30 40 50

図番 昭和電機株式会社 伊賀工場DWG.№ SHOWA DENKI CO.,LTD. IGA FACTORY

T2V12STDMAX4.6K_0.92_0.15標 4

品名/形式TYPE

May.25.2006

2006.5.25

M.MATSUURA性 能 曲 線 図 PERFORMANCE CURVE

作成DRAW

作成日DATE

承認APPROVE Y.UCHIDA

CTB0820-Y010

kg/m31.2

電動機MOTOR

軸動力SHAFT POWER

Hz

※周波数FREQUENCY

風 量VOLUME

備 考NOTES

密 度 DENSITY

電 圧VOLTAGE

温 度TEMPERATURE 20℃

※印仕様は、仕様書による。※ REFER TO SPECIFICATIONS.

静 圧STATIC PRESSURE

回転速度/回転数FAN SPEED

20

THE MEASURING POINT AWAY

1m FROM OPENING

吸込

口正

面1

m位

40

80

60

風量 (m3/min)Volume

全圧効率Fan Eff.

静  圧St Press.

軸 動 力Shaft Power

騒 音 dB(A)

Noise

騒 音 dB(A)

Noise

騒  音Noise

静 圧 (kPa)

St.Press.

軸動力 (kW)

Shaft Power

全圧効率 (%)

Fan Eff.

7 8

10.0

8.0

9.0

Static pressure (kPa)

6.0

5.04.5

4.0

3.5

3.0

2.5

2.22.01.8

1.5

1.2

1.0

0.8

0.6

0.4

0.2

0.1

10 20 30 40 60 80 100 120 150 200 250 300 400 500 600 800 1000 1200 1500 2000

4036

32282422

2018

161412

10

08Nominal number

T2V-Type Turbo Fan Delturbo with V-Belt Drive FeaturesA middle-pressure high-capacity type. This fan has load-limiting characteristics to prevent motor overloading due to changes in shaft power according to design point.

� Type T2V⓪⑧ (Nominal number)

� Uses Dust remover and collectorHot blast circulatorDryerIncinerator

Smoke exhaust apparatusCombustion apparatusBoilerFood/chemicals related equipment

Air blower/exhaust apparatus for various plant equipmentMiscellaneous

Air volume (m³/min)

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Turbo Blower B2V/B3V

12.0Static pressure (kPa)

9.5

10.0

11.0

9.0

8.5

8.0

7.5

7.0

6.5

6.0

5.5

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

4 5 10 15 20 30 40 50 60 70 90 11080

140120100

Air volume (m³/min)

9 10

B2V-Type Turbo Blower with V-Belt Drive B3V-Type Turbo Blower

10

06

10

05

08

04

06

03

05

12.0

11.5

11.0

10.5

10.0

9.5

9.0

8.5

8.0

7.5

7.0

6.5

6.0

5.5

5.0

4.5

4.0

Static pressure (kPa)

10 15 20 25 30 35 40 50 60 7080

90100 120110

140130 150

Air volume (m³/min)

Nominal number

Nominal number

Features

� Type B2V⓪③ (Nominal number)

� Uses For burner combustion airSecondary positive blowerAir transport apparatusDust collector

Apparatus related to air pollution controlHot blast blower for use in drying furnaces or annealing furnacesBlower for air conditioningAir supply/exhaust apparatus for various plant equipment and others

An energy-saving noise-reduction type of blower based on Non-Surger concept (Showa Denki's own technology).

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Airfoil Fan KT

11 12

KT-Type Airfoil Fan with V-Belt Drive

3.13.0

Static pressure (kPa)

2.8

2.6

2.4

2.22.12.0

1.8

1.6

1.4

1.2

1.1

1.0

0.8

0.6

0.5

0.4

0.3

0.2

20 30 40 50 60 80 100 120 150 180 200 220 250 300 400 500 600 800 1000 1200 14001600

18002000

220024002600

Air volume (m³/min)

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Features

0090

8070

60

55

5045

403530

� Type KT-③⓪ (Nominal number)

� Uses Air conditioning and ventilation in o�ce buildings and factoriesDryersCooling and air supply/exhaust for equipmentAir supply and exhaust for general applications

UV apparatusDehumidi�erWind tunnel test apparatusCoater and others

Nominal number

The bladed impeller of this fan ensures high

efficiency, low noise, and a large air volume.

Sirocco Fan M1V

13 14

M1V-Type Sirocco Fan with V-Belt Drive

1.10Static pressure (kPa)

1.00

0.90

0.80

0.70

0.60

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.08

0.06

0.05

20 30 40 60 80 100 120 150 200 250 300 400 500 600 800 1000 1200 1500 1800 2200 280030002000 2500

Air volume (m³/min)

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

A large-capacity low-pressure type, best suited to

the applications requiring a large volume of air.Features

36

32

40

28

24

22

2018

1614

12

10

0806

� Type MIV⓪⑥ (Nominal number)

� Uses Air conditioning and ventilation in o�ce buildings and factoriesDryersCooling and air supply/exhaust for equipmentAir supply and exhaust for general applications

Wind tunnel test apparatusMiscellaneous

Nominal number

Plate Fan P1V

15 16

P1V-Type Plate Fan with V-Belt Drive

� Type P1V⓪⑧ (Nominal number)

� Uses PowderDust collector for solids/�brousBoilerDryer

Air transport apparatusIncineratorFan for potentially corrosive gasesAir supply/exhaust for use with various equipmentMiscellaneous

3.00Static pressure (kPa)

2.50

2.80

2.202.102.00

1.80

1.50

1.20

1.00

0.80

0.60

0.50

0.40

0.30

0.25

0.20

0.18

0.160.15

10 15 20 25 30 40 50 60 80 100 120 150 200 250 300 400 500 600 800 1000Air volume (m³/min)

Features

28

24222018

16

1412

10

08Nominal number

A large-capacity low-pressure type.This fan is best suited to transporting air from powder or solids and to processing the high-concentration gases that contain dust.

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Plate Fan GP

17 18

GP-Type Plate Fan with V-Belt Drive

6.0Static pressure (kPa)

4.5

4.85.05.2

5.5

5.8

4.2

4.0

3.8

3.5

3.2

3.0

2.8

2.6

2.4

2.2

2.0

1.8

1.6

1.4

1.2

1.1

1.0

20 25 30 40 50 60 80 100 110 120 140 160 180200

210220

240260

280300

Air volume (m³/min)

A middle-pressure type. This fan is best suited to transporting air from powder

or solids and to processing the high-concentration gases that contain dust.Features

50

45

40

35

30

25

20

� Type GP-②⓪ (Nominal number)

� Uses PowderDust collector for solids/�brousBoilerDryer

Air transport apparatusIncineratorFan for potentially corrosive gasesAir supply/exhaust for use with various equipmentMiscellaneous

Nominal number

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Motor-Connected A

xial-Flow Fan

19 20

Axial Flow Fan with Variable Blade Pitch (A1D type and A2D type) "Kairyu"

Notes:- Further detailed dimensional outline drawings and performance curve

sheets can be downloaded from our Website.

Motor-Connected type

1010

1010

99

9 9

88

8 8

77

7

66

6

6

55

5 5

44

4

4

3

3

33

A1D 60HzA1D 50Hz

A2D 50Hz A2D 60Hz

A low-noise type that reduces noise by up to about 15 dB (A).Direct driving by direct connection to a motor shaft eliminates the need for maintenance such as belt tension adjustment and belt replacement.In addition, rotating sections are housed inside the machine to ensure human safety.

Features

0.5

1.8 1.71.6 1.51.41.3

1.21.1

1

0.8

0.60.5

0.40.350.30.25

0.2

0.15

0.120.1

0.08

0.450.4

Static pressure (kPa)

Static pressure (kPa)1.61.4

1.2

1.5

1.3

11.1

0.8

0.6

0.5

0.40.35

0.3

0.250.220.20.180.16

0.15

Static pressure (kPa)

0.350.30.250.220.20.180.15

0.120.1

0.08

0.060.05

0.04

0.030.025

0.02

0.7

0.50.550.6

0.45

Static pressure (kPa)

0.40.350.3

0.25

0.20.18

0.15

0.12

0.1

0.080.070.060.0550.050.0450.04

10

20 25 30 40 50 60 80 100 120 150 200 300 400 500 20 30 40 50 60 80 100 120 150 200 250 300 400 500600700 900 1100 1300 1500800 1000 12001400

600700 900 11001300800 1000 1200

15 20 25 30 40 50 60 80 100 120 150 200 250 300 400 5006007008009001000

Air volume (m³/min)

10 15 20 25 30 40 50 60 80 100 120 150 200 250 300 400 500600700800900 11001000

Air volume (m³/min)

Air volume (m³/min)

Air volume (m³/min)

� Type A1D③ (Nominal number)

� Uses Air supply and exhaust at tunneling worksitesGeneral air conditioningAir supply and exhaust in industrial plantsVentilation in basements

Air conditioning at underground parking areasO�ce buildings air conditioningMiscellaneous

Nominal numberNominal number

Nominal number

Nominal number

Axial-Flow

Fan with V-Belt

21 22

Axial Flow Fan with Variable Blade Pitch (A1V type and A2V type) "Kairyu" V-belt Features

Notes: - This fan is manufactured on a custom-design basis. Please contact our sales department for further details. The telephone numbers and addresses of our sales offices and branches are listed on the back cover of this catalog.

0.9

0.8

0.7

Static pressure (kPa)

0.60.55

0.5

0.45

0.4

0.35

0.3

0.25

0.2

0.18

0.15

0.12

0.1

0.08

0.07

0.06

0.05

0.04

0.03

0.02

0.9

0.8

0.7

Static pressure (kPa)

0.60.55

0.5

0.45

0.4

0.35

0.3

0.25

0.2

0.18

0.15

0.12

0.1

0.08

0.07

0.06

0.05

0.04

0.03

0.02

60 100 120 180 220 300 40045080 110 150 200 250 350500

600700

800900 11001000

Air volume (m³/min)

60 100 120 180 220 300 40045080 110 150 200 250 350500

600700

800900 11001000

Air volume (m³/min)

10

10

8

8

7

7

6

65

5

9

9

Without in-tube cover With in-tube cover

Since the fan speed can be adjusted by changing a combination of pulleys, multiple units of performance can be set up with one fan.

Agitating CM/CA

23 24

CM In-Furnace Agitating Fans with V-Belt Drive

0.5Static pressure (kPa)

0.45

0.4

0.35

0.3

0.25

0.2

0.15

0.1

0.05

0

0.5Static pressure (kPa)

0.45

0.4

0.35

0.3

0.25

0.2

0.15

0.1

0.05

0

20 30 40 50 60 80 100 120 150 200 250 300350400450500

600700800

10001200

65.5

54.543.53

2.521.5

Air volume (m³/min)100

110120

140160

180200220

250300

350 450 550 700 900400 500 600 800 1000

Air volume (m³/min)

7∅500

∅600 ∅700∅800

∅900∅1000

A sirocco type of

agitating fan.Features

CA In-Furnace Agitating Fans with V-Belt Drive

An axial-flow type

of agitating fan.Features

Notes: - This fan is manufactured on a custom-design basis. Please contact our sales department for further details. The telephone numbers and addresses of our sales offices and branches are listed on the back cover of this catalog.

Electric Blowers 50H

z/60Hz

Not useable on ranges.Not useable on ranges.Not useable on ranges.

25 26

Electric Blowers

50Hz 60Hz

Electric Blowers

Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.

Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.

3.2

2.8

2.0

1.6

0.2

0.8

0.4

0

3.0

2.5

2.0

1.5

1.0

0.5

0

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

2.0

1.6

1.2

0.8

0.4

0

5.0

4.0

3.0

2.0

1.0

0

0.6

0.5

0.4

0.3

0.2

0.1

0

2.0

1.6

1.2

0.8

0.4

0

8.0

10.0

6.0

4.0

2.0

0

16.0

14.0

18.0

10.0

12.0

8.0

6.0

4.0

2.0

0

30.0

25.0

20.0

15.0

10.0

5.0

0

3.2

2.4

1.6

0.8

0

2.8

2.0

1.2

0.4

6.0

4.0

5.0

3.0

2.0

1.0

0

0.7

0.5

0.3

0.6

0.4

0.2

0.1

0

2.4

2.0

1.6

1.2

0.8

0.4

0

28.0

24.0

20.0

16.0

12.0

8.0

4.0

0

4.0

3.5

2.5

1.5

0

3.0

2.0

1.0

0.5

2.8

2.4

2.0

1.2

1.6

0.8

0.4

0

14.0

12.0

8.0

10.0

6.0

4.0

2.0

0

20.0

17.5

15.0

10.0

12.5

7.5

5.0

2.5

0

35.0

30.0

25.0

20.0

15.0

10.0

5.0

0

15.0

18.0

21.0

24.0

12.0

9.0

6.0

3.0

0

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

50Hz

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

0 5 10 15 20 25 30 35 40 0 20 40 60 80 120100 0 5 15 25 3510 20 30 40 0 20 60 100 12040 80 140

0 4 12 208 16

0 10 30 5020 40 605 25 4515 35 55

0 0.8 1.6 2.40.4 2.01.2

0 4 8 102 6

0 10 3020 40 50 60 70 0 21 3

0 4020 603010 50

0 42 531

0 10 20 30 40 7050 60 0 1 2 3

0 20 40 605 25 4510 30 5015 35 55 0 20 40 6010 30

0 12 164 8 0 0.6 1.4 1.80.2 1.00.8 1.60.4 1.2

0 3 7 81 542 6

50

0 2 4 4.51 3

EC-63S/T

EC-75S/T

EC-125

SB-201/202

AH-H37

AH-H07

AH-H10

AH-H15

AH-H22AH-H04

FS-2200

U2V-220

U100B-H55U100B-H56

U100B-H45U100B-H46 U100B-H35

U100B-H36U100B-H5

U75-H4

U75-H3U75-H2 U100B-H26

U2V-150

U2V-70T

U2V-40T

U2V-30T

U2V-20T

U2V-10TU2V-07T

U2V-220U2V-150

U2V-70T

U2V-40T

U2V-30T

U2V-20T

U2V-10T

U2V-07T

FS-1500FS-750FS-400

FS-200FS-150

FS-2200

FS-1500FS-750

FS-400

FS-200FS-150

SF-55S

SF-50

SB-151SF-38

SB-201/202

AH-H37AH-H07

AH-H10

AH-H15AH-H22

AH-H04

SF-55S

SF-50

SB-151SF-38

EM-125M2

SBT-600

KSB-H07B KSB-H15BKSB-H15KSB-H22BKSB-H22

KSB-H07

KSB-H37B

KSB-H37

KSB-H04

U2V-70S

U2S-370

U2S-220

U2S-750U2S-150

U2S-70T

U2S-40T

U2V-40S

U2V-30SU2V-20S

U2V-10S

U2V-07S

SBT-600P

SB-600SB-600PSB-150

SF/SB-100SF/SB-75

SB-180

SBT-600

U100B-H56U100B-H46

U100B-H36

U75-H5

U100B-H26U75-H4U75-H3U75-H2

KSB-H37

KSB-H37B

KSB-H22

KSB-H15B

KSB-H22BKSB-H15

KSB-H07

KSB-H07B

KSB-H04

U2V-70S

U2S-370

U2S-220 U2S-750

U2S-150

U2S-70T

U2S-40T

U2V-40S

U2V-30S

U2V-20S

U2V-10S

U2V-07S

SBT-600P

SB-600

SB-600PSB-150

SF/SB-150

SF/SB-75

SB-180

EC-100S/T

EM-100T7

EC-63S/T

EC-75S/T

EC-125

EM-125M2

EC-100S/T

EM-100T7

Not useable on ranges.

Not useable on ranges.Not useable on ranges.

Not useable on ranges.

Not useable on ranges.Not useable on ranges.

Not useable on ranges.

All-purpose series Low-noise series

High-pressure series General-purpose series

General-purpose series Flange-installed series

Multi-stage series High-pressure vortexseries blowers

(U2V single-phase)

High-pressure vortexseries blowers

(U2V three-phase)

All-purpose series

High-pressure series

General-purpose series

Multi-stage series

High-pressure vortexseries blowers

(U2V three-phase)

High-pressure vortex series blowers (U2S)

Low-noise series

General-purpose series

Flange-installed series

High-pressure vortexseries blowers

(U2V single-phase)

High-pressure vortex series blowers (U2S)

A motor shaft directly connected blower of aluminum-molded casing construction. About 20,000 models are available.

Features

Denchoku 50H

z/60Hz

27 28

Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.

Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.

2.4

0.8

0.6

0.4

0.2

0

1.2

0.8

1.0

0.6

0.4

0.2

0

2.0

1.6

1.2

0.8

0.4

0

4.5

3.5

2.5

1.5

0.5

2.0 6.0

5.0

4.0

3.0

2.0

1.0

0

1.6

1.2

0.8

0.4

0

7.0 10.0

9.0

8.0

7.0

6.0

5.0

6.0

5.0

4.0

3.0

2.0

2.0

1.6

1.2

0.8

0.4

0

1.6

1.2

0.8

1.0

0.6

0.4

0.2

0

3.0

2.6

2.2

1.8

1.4

1.0

0.6

3.0

2.5

2.0

1.5

1.0

0.5

0

10.0

9.0

8.0

7.0

6.0

5.0

4.0

1.2

0.8

0.4

0

2.8

1.6

0.8

1.2

0.4

1.0

6.0

5.0

4.0

3.0

2.0

1.0

6.0

5.0

4.0

3.0

2.0

1.0

0

15.0

14.0

13.0

12.0

11.0

10.0

9.0

2.4

1.6

0.8

0

2.2

1.8

1.4

1.0

0.6

0

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

K1D typeAirfoil fan

M2D typeSirocco fan

T1D typeTurbo fan

T2D typeTurbo fan

B1D typeTurbo blower

K1D typeAirfoil fan

M2D typeSirocco fan

T1D typeTurbo fan

T2D typeTurbo fan

B1D typeTurbo blower

0

0 20 40 60 80 100 200

0

0

20

20

40

40

60

60

80

0 10 20 30 40 50 60

80 100 120

50 100 150 200 0 100 200 400300 500 600 0 50 100 150 200

10 50 210130 17090 250

0 20 12010060 8040 140

60 100 260180 220140 280

0 100 300200 400

0 100 300200 500400 600

0 20 6040 80 100

0 10 3020 5040 60

10 30 70 11050 90 130

20 40 80 12060 100 1400 100 200 300 400

0 40 80 12020 60 100 140

0 100 200 300 350

0 60 120 240180 300

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Static pressure (kPa)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

Air volume(m³/min)

This type, compared with the V-belt driven type, saves a floor area requirement by about 50% and uses fewer parts and accessories. In addition, it requires no belt tension adjustment.

Features

K1D4③

K1D5②K1D5①K1D4②

K1D4①

K1D5②K1D5①

K1D4②

K1D4①

K1D6①

M2D3①

T1D4①

T2D4①

B1D5①

B1D6①

B1D7①

B1D5①

B1D6①

B1D7①

T2D4② T2D4③

T2D5①

T2D5②

T2D6①T2D6② T2D6③

T2D5③

T2D4①

T2D4② T2D4③

T2D5①

T2D5②

T2D5③

T1D4②

T1D5① T1D5②

T1D4①

T1D4②

T1D5①

M2D5①

M2D4③

M2D4②

M2D5②

M2D5③

M2D3②M2D3③M2D4①M2D3④

M2D3⑤

M2D3⑥

M2D3①

M2D3⑥

M2D5①

M2D5②

M2D3②M2D3③M2D4①M2D3④

M2D4③

M2D3⑤

M2D4②

K1D6②K1D7①K1D7②K1D8①K1D8②K1D9①K1D9②

K1D6①

K1D6②K1D7①K1D7②

K1D8①K1D8②

M2D2⑥M2D2⑤

M2D2④

M2D2③

M2D2②

M2D1②

M2D2①

M2D2①

M2D2⑥

M2D2④

M2D2⑤

M2D2②

M2D2③

M2D2①

M2D1②

M2D1①

T1D3②

T1D3①

T1D2②

T1D2①

T1D3②

T1D3①T1D2②

T1D2①

T2D3③

T2D3②

T2D3①

T2D2③

T2D2②

T2D2①

T2D3③

T2D3②

T2D3①

T2D2③

T2D2②

T2D2①

B1D4①B1D3①

B1D2①

B1D1①

B1D4①

B1D3①

B1D2①

B1D1①

50Hz 60Hz

Denchoku (Motor-Connected Type of Welded Construction)

Heat-resistant fan connected directly to motor shaft Stainless steel sirocco fan

Agitating fan

Teflon-coated coupling turbofan

Emergency exhaust gas engine fan

Wear-resistant fan

Wind tunnel test apparatus

29 30

Custom-design cases

Motor shaft-connected fan resistant to high temperatures up to 350 degrees

Fan for stirring up air in a tempering furnace

Teflon-coated fan highly resistant to corrosion

Sirocco fan for dryers

This fan is engine-driven to allow operation even in an emergency such as a power interruption.

Plate fan designed to withstand wear

This wind tunnel test apparatus uses the variable blade pitch axial-flow fan "Kairyu" of 900 mm in diameter.

(Approx. size: 8.3 m x 3.2 m)

Showa Denki's fans and blowers support various custom designs.Here are examples of actual custom products:

In-furnace agitating axial-flow fan

Fan for agitation in drying furnaces

This test apparatus uses the high-efficiency large-capacity variable

blade pitch axial-flow fan "Kairyu". Inside the wind tunnel, a

wire mesh and straightening plates, as well as a honeycomb

structure, are provided to maintain a uniform in-channel

cross-sectional airflow for straightening. The diameter of the outlet

port is 500 mm, and the maximum velocity is 50 m/s (180 kmph).

Custom-design cases

(Turbo fan)Air volume: 220 m3/min, Static pressure: 2.58 kPaMotor: 15 kW, 2P, 50 Hz� Intake air temperature: 350 deg (maximum)� Bearing: Air-cooled type� Others: Despite resistance to high temperatures, Denchoku (direct motor

shaft connection) speci�cations provide the highly e�cient, compact design.

(Sirocco fan)Air volume: 620 m3/min, Static pressure: 0.3 kPaMotor: 7.5 kW, 4P, 60 Hz� Material: SUS304 for gas contact region� This fan was manufactured to suit the dimensional limits of the user

equipment.� The motor is mounted on top of the casing to implement the compact

design.

(Turbo fan)Air volume: 45 m3/min, Static pressure: 2 kPaEngine output: 4.3 kW� Shaft seal: Bypass labyrinth seal (Construction in which the high-pressure gas

at the shaft seal is suctioned using an intake-side vacuum pressure to minimize leakage from the shaft seal)

� Others: Anti-vibration rubbered frame and intake/outlet expansion coupling (Nylon tarpaulin)

(Plate fan)Air volume: 31 m3/min, Static pressure: 1.75 kPaMotor: 3.7 kW, 4P, 50 Hz� Casing: Inner surface treated by wear-resistant thermal spraying. A

chromium-based alloy is sprayed to a thickness of 0.1 mm.� Impeller: Treated by wear-resistant thermal spraying.

A hard build-up welding rod based on tungsten carbide is used on the �ow region.� Intake port: Totally removable construction� The casing and the bearing pedestal are of separable construction to allow

replacement of the casing.

(Axial-�ow fan)Air volume: 400 m3/min, Static pressure: 0.50 kPaMotor: 11 kW, 4P, 60 Hz� Material: SUS304 for impeller, shaft, and gas contact region� Intake air temperature: 300 deg (maximum)� Impeller diameter: 740 mm� Bearing: Air-cooled type� Others: This fan is of furnace ceiling-mounted construction with its impeller

facing downward.

(Turbo fan)Air volume: 30 m3/min, Static pressure: 2.94 kPaMotor: 3.7 kW, 2P, 60 Hz� Materials: SUS304 for gas contact region and Te�on-coating for casing and

intake port� Shaft seal: Te�on sheet packing� Others: The casing and the bearing case are of separable bolted construction

to allow independent replacement of the casing.

� Material: Stainless steel� Applications: Agitating the inside of a drying furnace for a uniform

temperature distribution� Intake air temperature: 150 deg (maximum)� Impeller diameter: 630 mm� Others: Directly connected to motor

Temperature Conversion Shaft Seal

Optional Shaft Seals

31 32

Technical Information/Data 1 Technical Information/Data 2Technical Inform

ation/Data

Precautions for selection Showa Denki's standard shaft seals

Packing seals (For fans/blowers: Iga Factory products)

Mechanical seal (Contact seal)

P1 = Speci�ed static pressure at a gas temperature "t" of 1°C

P2 = Speci�ed static pressure at a gas temperature "t" of 2°C

L1 = Speci�ed shaft power at a gas temperature "t" of 1°C

L2 = Speci�ed shaft power at a gas temperature "t" of 2°C

Air volume: Q2 = Invariant (m3/min)

List of temperature conversion coefficients

Static pressure: P2 = P1 × (kPa)273+t2

273+t1

Shaft power: L2 = L1 × (kW)273+t2

273+t1

Temp (°C) Coe�cient Temp (°C) Coe�cient Temp (°C) Coe�cient Temp (°C) Coe�cient

Kind of seal Types of fan/blowers

0102030405060708090

100110120130140150160170180190

200210220230240250260270280290300310320330340350360370380390

400410420430440450460470480490500510520530540550560570580590

600610620630640650

0.930.971.001.031.070.101.141.171.201.241.271.311.341.381.411.441.481.511.551.58

1.611.651.681.721.751.781.821.851.891.921.961.992.022.062.092.132.162.192.232.26

2.302.332.372.402.432.472.502.542.572.602.642.672.712.742.772.812.842.882.912.95

2.983.013.053.083.123.15

Glass clothLow-pressure and middle-pressure turbofans/plate fans

Floating sheet

Fan/blower shaft

Casing interior

Casing interior

Packing seal

Fan/blower shaft

Outside Inside B

d2 d d3

B1d2 : Maximum diameterd3 : Minimum diameter

d1

Seal ring

Coil spring

This seal conducts sealing on two planes perpendicular or almost perpendicular to the fan/blower shaft. One of the planes is used as a rotary plane, and the other is used as a stationary plane. Packings are also referred to as edge seals, and of these seals, shaft-sealing devices having a buffer mechanism to maintain the to-be-sealed planes in an appropriate contact status are referred to as mechanical seals.Advantage: - Virtually no leakageDisadvantages: - Complex in structure, and expensive. - Difficult to replace.

Labyrinth seal (Non-contact seal)

This seal forms very small clearances between a rotor and a stator. The gas usually leaks and decreases in pressure while the flow of the gas alternates between the relatively wide clearances and relatively narrow ones of the formed clearances. The seal utilizes the event.This type of seal is used in the cases that the surface velocity of the fan/blower shaft exceeds 12 m/s and that a slight amount of gas leakage from the casing is allowed.Advantages: - No sections suffer wear because of non-contact. - Easily responsive to thermal expansion.Disadvantages: - Sealing performance during slow rotation and

under a stopped state is relatively low.

V-rings (For electric blowers: Daito Factory products)

The V-ring, made from 100% homogeneous rubber, has its ribs and body coupled via hinges.The V-ring is mounted for sealing against dust and moisture, and this ring is provided as a standard component in virtually all middle-size and larger electric fans and blowers manufactured at the Daito Factory.

Heat-resistant type

Intake Air Temperatures and the Types of BearingsIntake air

temp

Bearing type

Above -10°C, but up to 50°C

Standard Heat-resistant Heat-resistant (Air-cooled) Heat-resistant (Water-cooled)

Standard grease Heat-resistant grease Heat-resistant grease Heat-resistant greaseStandard (2.5Y6/2) Heat-resistant silver (Standard for up to 80°C)

Munsell 2.5YR 6/13

Heat-resistant silver Heat-resistant silver

Above 50°C, but up to 150°C

Above 150°C, but up to 350°C

Above 350°C, but up to 650°CDepends on model and speed

Construction

LubricationFan/blower coatingGuards coating

Shaft seal Shaft sealShaft seal

Cooling fan Cooling fan

Water-cooling metal

Shaft seal

The fan/blower performance curve sheets in the catalog are based on a standard state of 20˚C. Even for identical fans/blowers, when the temperature of the gas being to be handled changes, specified points (design criteria) will change as follows per the following calculation expressions:

� The shaft seal refers to that of the region at which the fan/blower penetrates the casing. The shaft-sealing device is needed to prevent the gas inside the casing from leaking from the shaft seal, or to prevent the atmosphere from flowing from the shaft seal into the casing.

� If the kind of gas to be handled is standard air and the static pressure is up to nearly 1 kPa, there is no need to provide the shaft-sealing device. In general, packings and/or labyrinth seals are used in fans.

Notes: Air changes in volume according to temperature and pressure, and will expand when the temperature rises. When air expands, mass will decrease even if the volume remains the same.However, since the air volume, as expressed in terms of m3/min or m3/h, is a volumetric flow rate that represents the volume per unit time, the air volume will remain invariant, even when the temperature rises.

Technical Information/D

ata

T1,T2V40

Details of impeller mounting �xture

2524

Details of impeller mounting �xture

T1,T2V08 to 10

22

21

23

2018 191716

15

14

1312111098

7654321

14

1211

7

6

5

3

2

1

13

8

9

4

10

16

15

1413121110987

6

5

4

3

2

1

Construction of Fans and Blowers Energy-saving Effects of Reducing the Fan/Blower Speed by 10%

Storage of the Fan/Blower

Roller Ball Dropping Sound

33 34

Technical Information/Data 3 Technical Information/Data 4

If the fan/blower is stored or shut down with the rotating shaft of the impeller remaining stopped for at least about three months in succession, contact sections between the balls of the bearing and the track surface may suffer oil film breakage, depending on the season or the environment. If this is the case, unusual sounds will result from unwanted events such as corrosion.Remove the bearing guard periodically (at least once a month) and manually rotate the shaft through about 10 turns to prevent bearing corrosion.

Precautions for storage

The roller ball dropping sound of the fan bearing features the following

� V-belt drive

� Tapered shaft/holes adopted for fan/blower mounting fixtures

� Directly connected to coupling

� Denchoku standards

(1) Store your product at a dry location with minimum changes in indoor temperature.(2) Shroud your product with waterproof sheeting to protect the product from moisture, oils, dust, and the like.(3) Avoid storage in a place exposed to direct sunlight, strong vibration or heat, and the like. Also, avoid contact with a cold

wall.

(1) Upon moving from a non-loaded area into a loaded area, the roller becomes free to move and the balls start to roll by gravity, thus hitting the retainer to generate the sound.

(2) The magnitude of the sound varies from product to product.(3) The sound level increases and decreases.

(1) The internal clearances of the heat-resistant bearings and other bearings of the B2V and B3V blowers which rotate at high speed are preset to be C3 clearances allowing for expansion due to bearing temperature rises to at least about 150˚C.

(2) Since the C3 clearances are large in comparison with CN clearances, the roller ball dropping sound may occur under relatively low bearing temperatures.

Bearing clearances

Storage location

6

5

4

3

2

1

0

240

200

160

120

8099

72

40

00 500 1000

10801200

20001500 2500

(kPa)

Static pressure

Shaft power

(BkW) � Fan/blower speed

1120 min-1

1012 min-1

10% down

� System air volume

1200 m3/min

1080 m3/min

10% down

� Shaft power

Air volume (m³/min)

99 kW

72 kW

27% downPart No.

123456789

10111213141516171819202122232425

Qty111121

2 sets1 set

121111111111111

1 set1

Intake portImpellerCasingBearingBearing housing bodyBearingBearing housing coverCasing shaft sealShaftPillow-type unitBearing guardBelt guardParallel key for V-pulleyHolder for V-pulleyBolt for holderHub-locking nutLock washerImpeller hubParallel key for impellerCommon baseV-pulleyBolt for holderHolder for impellerHexagon socket setscrewHolder for impeller

Part NameLow-carbon steelLow-carbon steelLow-carbon steel

FC200

FC200Non-asbestosS45C

Low-carbon steelLow-carbon steelS45CLow-carbon steelLow-carbon steelLow-carbon steelLow-carbon steelFC200S45CLow-carbon steelFC200Low-carbon steelLow-carbon steelSCM435FC200

Material

Part No.123

456789

10111213141516

Qty111

121211111

1 set111

CasingIntake portImpeller

Parallel keyHolder setboltHolderShaft sealCounter-drive bearingShaftDrive bearingBearing guardCoupling guardCouplingMotorBearing/motor baseBase

Part NameLow-carbon steelLow-carbon steelLow-carbon steel, High-strength steelS45CLow-carbon steelFC200Non-asbestos

S45C

Low-carbon steelLow-carbon steel

Low-carbon steelLow-carbon steel

Material

Part No.12345678

91011121314

Qty11111111

1 set11111

CasingImpellerIntake portIntake case �angeParallel keyHolderHolder setboltMotor

PackingOutlet case �angeShaft sealShaft seal clampShaft guardMotor base

Part NameLow-carbon steelLow-carbon steelLow-carbon steelLow-carbon steelS45CLow-carbon steelLow-carbon steelMotor manufacturer's standards

Low-carbon steelNon-asbestosLow-carbon steelLow-carbon steelLow-carbon steel

Material

Impeller hub

Parallel key

Hex socket setscrew

Shaft-locking nut

Lock washer

* Maintainability signi�cantly improves.

Shaft

Advantages(1) Saves impeller mounting/dismounting time.(2) High-temperature specifications: Any effects of thermal distortion on hub holes

and shaft are minimized.(3) Stainless steel specifications: Hub hole/shaft fusion (scuffing) can be prevented.

Applicable modelsT1/T2-12 to 36 Cantilever type, Belt-driven type, Coupling-driven typeB2-04 to 10, B3-05 to 10 Cantilever type, Belt-driven type, Coupling-driven typeM1-14 to 32 Cantilever type, Belt-driven type, Coupling-driven typeKT-30 to 90 Cantilever type, Belt-driven type, Coupling-driven type

Quadratic system loss curveDecreases in air volume reduce pressure loss in proportion to the square of the air volume.