page 12 to page 23
MICR
OOP
TIMIZE
RUN
OTR
IOLIT
EPL
USUL
TRA
STAT
ION
VISIO
NW
IND
SERV
ICE
page 24 to page 71
page 72 to page 107
page 108 to page 113
page 114 to page 167
page 168 to page 217
page 218 to page 227
PVI-2000/3600 p. 26 PVI-3.0-TLp. 38
PVI-5000-TLp. 50
PVI-10.0-TLp. 64
PVI-3.6-TL PVI-6000-TL PVI-12.5-TLUNO-2.0-I
p. 30PVI-4.2-TL
UNO-2.5-IPVI-3.8-I
p. 44PVI-10.0-I
p. 58TRIO-27.6-TL
p. 68PVI-2000-OUTD p. 36 PVI-4.6-I PVI-12.0-I TRIO-20.0-TL
PVI-250.0-TLp. 74
PVI-55.0/110.0 p. 82 PVI-CENTRAL-50p. 88
PLUS-250.0-Ip. 96
PVI-500.0-TL PVI-CENTRAL-100 PLUS-500.0-IPVI-165.0/220.0 p. 84
PVI-275.0/330.0 p. 86 PVI-CENTRAL-250p. 92
ULTRA p. 102PVI-CENTRAL-300
MICRO-0.3-I p. 14 OPTI-0.3-TL p. 20
STATION p. 110
AURORAp. 126
AURORAp. 130 AURORAENVIRONMENTAL p. 148
PVI-AEC-EVO p. 162VISION UNIVERSAL
PVI-DESKTOP p. 164AURORA p. 128 AURORA
p. 142AURORA NETWORK p. 152
VISION PRIME SMART COMBINER AURORA p. 166STRINGCOMB p. 156 INSTALLER
LSWI-2.5MW p. 172 25kW WINDp. 184
4000 & 7200p. 196
SSWI-3.8-Ip. 206
INTERFACE WIND INTERFACE SSWI-4.6-IMSWI-55.0/110.0 p. 176
PVI-12.5-TL-W p. 188 PVI-5000-TL-Wp. 200
PVI-3.0-TL-Wp. 212MSWI-50/100-US p. 180 PVI-6000-TL-W PVI-3.6-TL-W
SSWI-10.0-I p. 192 PVI-4.2-TL-W
AURORAp. 220
AURORAp. 224
ADVANTAGE ALLIANCEAURORA
p. 218SERVICE
AURORAp. 222
AURORAp. 226
ASSURE ACADEMY
CONTACTS p. 228
Central Inverter
Small Wind
Single Phase
RESIDENTIAL PV INVERTERS
UTILITY PV CENTRAL INVERTERS
55 kW - 1400 kW
MICRO-0.25-I MICRO-0.3-I
OPTI-0.3-TL PVI-2000PVI-3600
UNO-2.0-IUNO-2.5-I
PVI-3.0-TLPVI-3.6-TLPVI-3.8-I
PVI-250-USPVI-300-US
SMALL WIND INVERTERS
PVI-3.0-TL-WPVI-3.6-TL-WPVI-4.2-TL-W
3 kW - 6 kWPVI-5000-TL-WPVI-6000-TL-W
SSWI-3.8-ISSWI-4.6-I
SSWI-10.0-IPVI-12.5-TL-W
4000 WIND INTERFACE7200 WIND INTERFACE25kW-WIND-INTERFACE
10 kW - 25 kW
300W - 4 kW
PVI-CENTRAL-50/100PVI-55.0/110.0PVI-165.0/220.0PVI-275.0/330.0
NEW NEW NEW
ULTRA-700-TLULTRA-1050-TL ULTRA-1400-TL
NEW
PVI-250.0-TLPVI-500.0-TL
NEW
Medium Wind
MEDIUM WIND
Large Wind
VisionTurnkey Solutions
Three PhaseSingle Phase
COMMERCIAL PV INVERTERS
PV STATION
PVI-4.2-TLPVI-4.6-IPVI-5000-TLPVI-6000-TL
PVI-10.0-TLPVI-10.0-I / PVI-12.0-IPVI-12.5-TL
TRIO-20.0-TLTRIO-27.6-TL
STATION 440/660-IT/DESTATION 770/1000-IT/DESTATION 1000/1320-IT/DE/US
SMALL WIND INVERTERS
PVI-AEC-EVOPVI-DESKTOP
LARGE WIND
55 kW - 110 kWMSWI-55.0MSWI-110.0
LSWI-2.5MW
turnkey solutions
4 kW - 30 kW
AURORA VISION
MSWI-50-USMSWI-100-US
AURORAUNIVERSAL
NEW
NEWNEW
AURORAENVIRONMENTAL
NEW
AURORASMART
COMBINER
Welcome to Power-One
Welcome from Dr Alex Levran
As President of Power-Ones Renewable Energy Solutions, I am excited to showcase our broad array of products and services for the Solar and Wind markets.
Power-One has a long-standing history in the global power electronics industry, providing a four-decades strong foundation for our technology innovation, quality and service within the Renewable Energy industry.
If you are new to our products, we off er the full range of photovoltaic and wind products, from small residential inverters to large utility-grade units. From the contents of this brochure, you will fi nd that we off er a diverse range of solutions to meet the needs of every installation.
At Power-One, our objective is to be the best-in-class for on-time delivery, reliability and yield. Since 2009, our company has risen from the number nine position amongst the worlds solar inverter manufacturers to the number two global position, shipping 2.6 GW of inverters in 2010. With our global presence, including design, manufacturing, sales and service in Asia, Europe and the Americas, we off er fl exibility, regionally specifi c products and rapid manufacturing and service response times for our customers throughout the world.
Our broad array of Aurora products off ers industry leading effi ciency and reliability, providing customers with a technologically advanced product that produces higher yields than our competitors. In fact, Photon Magazine said our European 10.0kW three-phase inverter, which received their A+ rating, takes its place among the top devices Photon Lab has tested so far.
Coupled with our innovative technology, we also provide our customers with excellent pre- and post-sales service. This ensures their orders are not only correct to their specifi cation before they receive the product, but that they also have an effi cient care package for increased uptime throughout the life of the inverter. This enables us to be more of a partner than a supplier to our customers, as we like to think of ourselves as our customers manufacturing arm no diff erent than if we were within their organizations.
On behalf of a very hard working team, we are looking forward to working with you as we provide our leading design, technology and service to meet your renewable energy needs. I encourage you to contact Power-One Renewable Energy Solutions team so that we can be the supplier of choice for all of your future renewable energy projects.
With best wishes
Dr. Alex Levran, President, Renewable Energy Solutions
New Products & Product Benefits
This global catalogue introduces a certain number of new products to the Power-One Aurora range. So far we have installed products totaling more than 4 GW of power globally. We have redesigned the smallest of our residential inverters, the new UNO 2 kW single phase inverter. A new look inverter from both a style and technology standpoint, it is high performing, extremely robust, easily installed and features a new user interface. Other important news includes two new string inverter products for large roof top applications, TRIO-27.6 and TRIO-20.0, three-phase inverters outputting 27.6 kW and 20.0 kW respectively. These products fi ll a gap between our previous 10.0 kW and 12.5 kW three-phase products and our smallest Central inverter products (50kW and 55kW). This new design of inverter benefi ts from three-phase inverter technology perfected in the PVI-10.0 and 12.5, probably the worlds most commonly used three-phase inverter which has led the way in best-in-class effi ciency. Power-One is also launching the new ULTRA, our biggest inverter with an output of up to 1.4MW featuring passive liquid cooling. This new concept in large scale utility inverter features an IP65 enclosure, high performances, minimum footprint, low maintenance and Power-Ones traditional modular approach. All this plus a low operational cost benefi t for our customers.
Key Features of the Aurora product range Power-Ones Aurora products compare favorably with the competition for the high innovation content and key features which are the stronghold of our offering. The wide working input voltage range can accommodate any panel string size, allowing installers to buy their inverter with confidence knowing the Aurora inverter will suit whatever installation they have on their books. The wide input range also allows a low power of activation to extend the daily working time of the inverter. The Aurora inverters also feature a rugged IP65 construction to fit any type of installation without putting restrictions on where and how the inverter should be installed. Maximum power-point trackers (MPPT) allow you to accommodate sub arrays with different orientations or made up of different PV panels. This technology also allows the installation designer to know that any incidents of partial shading will be overcome by the MPPT technology creating the optimum power curve for energy harvesting. Modular central inverters, used for large commercial and utility scale applications, allow a reduction in downtime caused either by the failure at the inverter level or the photovoltaic field. This eliminates plant shutdown, the reduction of repair time and consequently financial benefits in terms of production.At Power-One, we aim high so you can too.
Paolo CasiniVice President, Marketing
12 AURORA MICRO
MICRO
13AURORA MICRO
MIC
ROO
PTIM
IZER
14 AURORA MICRO
MICRO-0.25-IMICRO-0.3-I
GENERAL SPECIFICATIONSOUTDOOR MODELS
MICRO-0.25-I-OUTD-230MICRO-0.25-I-OUTD-208/240-US
MICRO-0.3-I-OUTD-230MICRO-0.3-I-OUTD-208/240-US
NEW
15AURORA MICRO
Features
MIC
ROO
PTIM
IZER
Electrolyte-free power converter to further increase the life expectancy and long term reliabilityOutdoor enclosure for unrestricted use under any environmental conditionsIncreased energy harvesting thanks to the MPPT algorithm which works at the level of each solar panel in any light conditionNo DC input current rippleThe HF isolation allows it to fit any application that requires the grounding of either one of the input terminations95.5% of efficiencyEase of installation by the implementation of a package inclusive of proprietary wireless communication hub and grid interfaceReduced susceptibility to fault. In case of a component failure only the energy produced from one PV module will be lostUp to 10 micro inverters directly connectable in a string
The new Aurora 300 Watt micro-inverter product off ers something new to Power-One customers. The ability to individually link all modules within a specific installation is an alternative to the traditional Aurora string inverters Power-One is famous for.
Micro-inverters have some advantages over string inverters. They allow you to control the panels output individually and off er Maximum Power Point Tracking (MPPT) for each single module.
They also allow you to control individual panels in diff erent ways and reduce the losses in efficiency in a variety of challenging conditions.
Block Diagram and Ef ciency Curves
16 AURORA MICRO
BLOCK DIAGRAM OF MICROINVERTER
IN1
+
-
MPPT 1(DC/DC) BULK CAPS
INVERTER(DC/AC)
EMIOUTPUT
FILTER
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
L1(1)
L2(1)
HFTRANSFORMER
EMIOUTPUT
FILTER
L1(2)
N2
WIRELESS
PE
N1
L2(2)
MICRO-0.3-I MICRO-0.3-I
25
35
40
45
50
55
5% 10% 20% 30% 50% 75% 100%
Vin
[V]
Eciency [%]
Pout [% @300W]
96-97 95-96 94-95 93-94 92-93 91-92 90-91 89-90 88-89 87-88 86-87 85-86 84-85 83-84 82-83 81-82 80-81 79-80 78-79 77-78 76-77 75-76 74-75
90
91
92
93
94
95
96
97
Eci
necy
[%]
Pout [%@300W]
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Vin=35V
Vin=40V
Vin=25V
17AURORA MICRO
PARAMETER MICRO-0.25-I-OUTDMICRO-0.3-I-
OUTDMICRO-0.25-I-
OUTD-USMICRO-0.3-I-
OUTD-US
Input SideMaximum DC Input Power (Pdcmax) 265 Wp 320 Wp 265 Wp 320 WpOperating DC Input Voltage Range (Vdcmin...Vdcmax) 17...60 V 17...60 VMPPT Input DC Voltage Range (VMPPTmin ... VMPPTmax) 20...50 V 20...50 VAbsolute Maximum DC Input Voltage (Vmax,abs) 65 V 65 VMaximum DC Input Current (Idcmax) 10.0 A 10.0 ANumber of DC Inputs Pairs for each MPPT 1 1DC Connection Type Tool Free PV connector WM / MC4 Tool Free PV connector WM / MC4Start-up DC Input Voltage (Vstart) 25V 25VOutput SideAC Grid Connection Type Single phase Single phase/Split phaseRated AC Power (Pac,r) 250 W 300 W 250 W 300 WRated AC Grid Voltage (Vac,r) 230 V 208 V / 240 VAC Voltage Range (Vacmin...Vacmax) 180...264 V
(1) 183-228 V / 211-264 VMaximum AC Output Current (Iac,max) 1.2 A 1.5 A 1.3 A / 1.15 A 1.5 ARated Output Frequency (fr) 50 Hz 60 HzOutput Frequency Range (fmin...fmax) 47...53 Hz
(2) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.95 > 0.95 Maximum number of units per string 10 10Output ProtectionAnti-Islanding Protection According to local standard According to local standardOutput Overvoltage Protection - Varistor Yes YesOperating PerformanceMaximum Efficiency (max) 96.0% 96.3% 96.0% 96.3%Weighted Efficiency (EURO/CEC) 95.4% / 95.5% 95.5% / 95.5% 95.4% / 95.5% 95.5% / 95.5%Stand-by Consumption < 50mW < 50mWCommunicationMonitoring System (PC/Data logger) Wireless WirelessRemote Monitoring Wireless WirelessEnvironmentalAmbient Temperature Range -40...+85C / -40...185F with derating above 65C/149F -40...+85C / -40...185F with derating above 65C/149FRelative Humidity 0...100 % condensing 0...100 % condensingNoise Emission < 30 db(A) @ 1 m < 30 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ft 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65 NEMA 4XCooling Natural NaturalDimension (H x W x D) 262mm x 244mm x 35mm / 10.3 x 9.6 x 1.37 262mm x 244mm x 35mm / 10.3 x 9.6 x 1.37Weight < 1.65 kg / 3.5 lb < 1.65 kg / 3.5 lbSafetyIsolation Level HF Transformer HF TransformerMarking CE cCSAus
Safety and EMC Standard EN61000-6-2, EN61000-6-3, EN61000-3-11, EN61000-3-12, EN 50178 EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, UL 1741
Grid Standard VDE0126-1-1, DK5940, AS4777, G83/1 IEEE 1547Available Products Variants
Standard MICRO-0.25-I-OUTD-230 MICRO-0.3-I-OUTD-230 MICRO-0.25-I-OUTD-US-208/240MICRO-0.3-I-OUTD-
US-208/240
1. The AC voltage range may vary depending on specific country grid standard
2.The Frequency range may vary depending on specific country grid standard
18 AURORA OPTIMIZER
OPTIMIZER
MIC
ROO
PTIM
IZER
19AURORA OPTIMIZER
OPTI-0.3-TL
GENERAL SPECIFICATIONSOUTDOOR MODELS
OPTI-0.3-TL-OUTDOPTI-0.3-TL-OUTD-US
NEW
20 AURORA OPTIMIZER
Features
21AURORA OPTIMIZER
MIC
ROO
PTIM
IZER
Ability to mitigate PV panel mismatchHigh efficiency up to 99.5%Single panel MPP tracker compatible with all Power-One inverter modelsEase of installation by the implementation of a package inclusive of proprietary wireless data communicationTemperature hardened construction
Power-Ones new Optimizer products use DC-to-DC technology to help maximize the energy harvested from solar installations.
Normally, within each array, the solar panels are usually joined together in a serial pattern. This creates issues if one panel fails as this reduces the energy being produced by the entire installation. The Optimizer maximizes the energy from each module within a string as they optimize the voltage/current for any given weather conditions.
The Optimizer also maximizes energy harvesting in panels suff ering from partial or temporary shading. This helps installers to create the largest installations possible andincrease Return on Investment (ROI).
Block Diagram
22 AURORA OPTIMIZER
BLOCK DIAGRAM OF OPTIMIZER WITH EXAMPLE OF CONFIGURATION
BLOCK DIAGRAM OF WIRELESS CONNECTION ARCHITECTURE
C
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
MPPT
WIRELESS
OPTI 0.3
CSTRING COMBINER INVERTER
OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3*
CDD#1(CONCENTRATOR DATA DEVICE)
CG(COMMUNICATION GATEWAY)
CDD#2(CONCENTRATOR DATA DEVICE)
CDD#N(CONCENTRATOR DATA DEVICE)
* EDD (END MODE DATA DEVICE)
INTERNET
23AURORA OPTIMIZER
PARAMETER OPTI-0.3-TL-OUTD OPTI-0.3-TL-OUTD-US
Input Side
Maximum Input Power (Pdcmax) 300 Wp 300 Wp
MPP Input range (VMPPTmin, f-VMPPTmax,f) at Full Power 20...60 V 20...60 V
Absolute Maximum Input Voltage (Vmax,abs) 65 V 65 V
Maximum Input Current (Idcmax) 10.0A 10.0A
Number of DC Inputs Pairs 1 1
DC Connection Type Tool Free PV connector WM / MC4 Tool Free PV connector WM / MC4
Maximum Output Power (Pdcmax) 300W 300W
Output Voltage Range (VdcminVdcmax) 20..60(1) V 20..60(1) V
Maximum Output Current (Idcmax) 12.0 A 12.0 A
Output Reverse Polarity Protection Yes Yes
Output Over Voltage Protection > 60 V > 60 V
Operating Performance
Maximum Efficiency (max) 98.0 % 98.0 %
Pass Through Efficiency (pt) 99.3% 99.3%
Weighted Efficiency (EURO/CEC) 98.2% / 98.0% 98.2% / 98.0%
Communication
Remote Control (Data logger; On/Off; Upgrade) Wireless Wireless
User Interface Not applicable Not applicable
Environmental
Ambient Temperature Range -40...+65C / -40...169F -40...+65C / -40...169F
Relative Humidity 0...100% condensing 0...100% condensing
Noise Emission < 30 db(A) @ 1 m < 30 db(A) @ 1 m
Operating Altitude 2000 m / 6560 ft 2000 m / 6560 ft
Physical
Environmental Protection Rating IP 65 NEMA 4x
Cooling Natural Natural
Dimension (H x W x D) 158mm x 169mm x 28.6mm / 6.2 x 6.65 x 1.12 158mm x 169mm x 28.6mm / 6.2 x 6.65 x 1.12
Weight < 0,6 kg / 1,32 lb < 0,6 kg / 1,32 lb
Safety
Marking CE cCSAus
Safety and EMC Standard EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B,EN 50178EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B,
UL 1741
Available Products Variants
Standard OPTI-0.3-TL-OUTD OPTI-0.3-TL-OUTD-US
1. Adjustable via wireless connection
24 AURORA UNO
UNO
25AURORA UNO
UN
OTR
IO
PVI-2000PVI-3600
GENERAL SPECIFICATIONSINDOOR MODELS
PVI-2000PVI-3600
26 AURORA UNO
Features
27AURORA UNO
UN
OTR
IO
Wide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
The smallest of Power-Ones Aurora PV string inverters, this unit is designed to be housed indoors as opposed to many of its outdoor counterparts.
This small residential string inverter will work most eff ectively with small photovoltaic residential installations. This very compact, slim, lightweight and easy-to-install inverter off ers a very cost eff ective entry point for users new to photovoltaics or in need of a simple power inverter solution.
The inverter off ers a range of benefits, including maximum energy harvesting, through both its high-speed Maximum Power Point Tracker (MPPT) and transformerless technology. The important parameter is the wide input voltage range making the inverter suitable to low power installations with reduced string size. The graphical display allows users to check real-time performance through its integrated data logger.
Block Diagram and Ef ciency Curves
28 AURORA UNO
PVI-2000 PVI-3600
85
87
89
91
93
95
97
99
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
220 Vdc
380 Vdc
480 Vdc
85
87
89
91
93
95
97
99
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
200 Vdc
380 Vdc
480 Vdc
BLOCK DIAGRAM OF PVI-2000 AND PVI-3600
IN1.1(+)
IN1.2(+)*
IN1.1(-)
IN1.2(-)*
IN
+
-
STANDARD VERSION
IN
+
-
MPPT (DC/DC) BULK CAPS
INVERTER(DC/AC)
LINEFILTER
GRID PARALLELRELAY
L
N
PE
RESIDUAL CURRENTDETECTION
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
(*) Not available for PVI-2000
29AURORA UNO
PARAMETER PVI-2000 PVI-3600
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 2100 W 3800 WNumber of Independent MPPT 1 2
Maximum DC Input Power for each MPPT (PMPPTmax)2100 W
Linear Derating From MAX to Null [530VVMPPT580V]
2000 W
MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 210...530 V 200...530 VDC Input Voltage Range with Parallel Configuration of MPPT at Pacr Not applicable 200...530 V
DC Power Limitation with Parallel Configuration of MPPT Not applicable Linear Derating From MAX to Null [530VVMPPT580V]
DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
Not applicable2000 W [200VVMPPT530V]
the other channel: Pdcr-2000W [180VVMPPT530V]
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 A 20.0 A / 10.0 AMaximum Input Short Circuit Current for each MPPT 12.0 ANumber of DC Inputs Pairs for each MPPT 1 2DC Connection Type Tool Free PV Connector WM / MC 3 / MC 4 (1)Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2 2 for each MPPTPhotovoltaic Array Isolation Control According to local standardOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 2000 W 3600 WMaximum AC Output Power (Pacmax) 2000 W 3600 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (2)Maximum AC Output Current (Iac,max) 10.0 A 16.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (3)Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 2.5 %AC Connection Type Circular connectorOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 16.0 A 20.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (max) 95.5% 96.0%Weighted Efficiency (EURO/CEC) 94.4% / - 95.0% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface Graphic displayEnvironmentalAmbient Temperature Range -20...+55C /-4...131F with derating above 40C/104FRelative Humidity 0...95 %Noise Emission < 30 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 21Cooling Air ForcedDimension (H x W x D) 440mm x 465mm x 57mm / 17.3 x 18.3 x 2.2Weight < 7.5 kg / 16.5 lb < 8.5 kg / 18.7 lb Mounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS/NZS 3100Grid Standard DK 5940, VDE 0126-1-1, G83/1, AS 4777Available Products VariantsStandard PVI-2000 PVI-36001. Different DC connection type for specific country model
2. The AC voltage range may vary depending on specific country grid standard
3. The Frequency range may vary depending on specific country grid standard
UNO-2.0-IUNO-2.5-I
GENERAL SPECIFICATIONSOUTDOOR MODELS
UNO-2.0-I-OUTDUNO-2.5-I-OUTD
UNO-2.0-I-OUTD-USUNO-2.5-I-OUTD-US
NEW
30 AURORA UNO
Features
31AURORA UNO
UN
OTR
IO
Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
The UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the Aurora range. A new-look inverter but packed with Power-Ones proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system.
The smallest of Power-Ones outdoor range, these new products are the right size for the average rooftop installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
The high speed MPPT off ers real-time power tracking and improved energy harvesting.
Despite the isolated operation, the UNO-2.0-I and UNO-2.5-I feature an efficiency of 96.3%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Block Diagram and Ef ciency Curves
32 AURORA UNO
UNO-2.0-I-OUTD UNO-2.5-I-OUTD
BLOCK DIAGRAM OF UNO-2.0-I AND UNO-2.5-I
90,00%
91,00%
92,00%
93,00%
94,00%
95,00%
96,00%
97,00%
98,00%
99,00%
200Vdc
300Vdc
350Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
90,00%
91,00%
92,00%
93,00%
94,00%
95,00%
96,00%
97,00%
98,00%
99,00%
200Vdc
300Vdc
350Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN
+
-
MPPT(DC/DC)
HFTRANSFORMER BULK CAPS
INVERTER(DC/AC)
LINEFILTER
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
GRID PARALLELRELAY
IN1
+
-
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
STANDARD VERSION
IN
+
-
-S VERSION
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
- L
- N
- PE
33AURORA UNO
PARAMETER UNO-2.0-I-OUTD UNO-2.5-I-OUTD
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 2100 W 2600 WNumber of Independent MPPT 1
Maximum DC Input Power for each MPPT (PMPPTmax)2300 W
Linear Derating From MAX to Null[470VVMPPT520V]
2900 WLinear Derating From MAX to Null
[470VVMPPT520V]MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 200...470 V 205...470 VDC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
Not applicable
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 A 12.8 A / 12.8 AMaximum Input Short Circuit Current for each MPPT 15.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 16 A / 600 VOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 2000 W 2500 WMaximum AC Output Power (Pacmax) 2200 W 2750 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)
Maximum AC Output Current (Iac,max) 10.0 A 12.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)
Nominal Power Factor (Cosphiac,r) > 0.995 (adj. 0.95)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 15.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (max) 96.3%Weighted Efficiency (EURO/CEC) 95.0% / - Feed In Power Threshold 24.0 WStand-by Consumption < 8.0 W (3)
CommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface Graphic display EnvironmentalAmbient Temperature Range -25...+60C (-13...+ 140F) with derating above 45C (113F)Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 518mm x 367mm x 160mm / 20.4 x 14.4 x 6.3Weight < 17 kg / 37.4 lbMounting System Wall bracketSafetyIsolation Level HF transformerMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS 4777Available Products VariantsWith DC Switch UNO-2.0-I-OUTD-S UNO-2.5-I-OUTD-S
1. The AC voltage range may vary depending on specific country grid standard
2. The Frequency range may vary depending on specific country grid standard
3. Night time consumption < 0.6W
Block Diagram and Ef ciency Curves
34 AURORA UNO
UNO-2.0-I-OUTD UNO-2.5-I-OUTD
BLOCK DIAGRAM OF UNO-2.0-I AND UNO-2.5-I
90,00%
91,00%
92,00%
93,00%
94,00%
95,00%
96,00%
97,00%
98,00%
99,00%
200Vdc
300Vdc
350Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
90,00%
91,00%
92,00%
93,00%
94,00%
95,00%
96,00%
97,00%
98,00%
99,00%
200Vdc
300Vdc
350Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN
+
-
MPPT(DC/DC)
HFTRANSFORMER BULK CAPS
INVERTER(DC/AC)
LINEFILTER
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
GRID PARALLELRELAY
IN1
+
-
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
STANDARD VERSION
IN
+
-
-S VERSION
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
- L
- N
- PE
35AURORA UNO
PARAMETER UNO-2.0-I-OUTD-US UNO-2.5-I-OUTD-US
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 2100 W 2600 WNumber of Independent MPPT 1
Maximum DC Input Power for each MPPT (PMPPTmax)2300 W
Linear Derating From MAX to Null [470VVMPPT520V]
2900 W Linear Derating From MAX to Null
[470VVMPPT520V]MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 200...470 V 205...470 VDC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
not applicable
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 A 12.8 A / 12.8 AMaximum Input Short Circuit Current for each MPPT 15.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC5Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 16 A / 600 VOutput Side 208 V 240 V 208 V 240 VAC Grid Connection Type Single phase / Split phaseRated AC Power (Pacr) 2000 W 2500 WMaximum AC Output Power (Pacmax) 2200 W 2750 WRated AC Grid Voltage (Vac,r) 208 V 240 V 208 V 240 VAC Voltage Range 183...228 V 211...264 V 183...228 V 211...264 VMaximum AC Output Current (Iac,max) 10.0 A 12.0 ARated Output Frequency (fr) 60 HzOutput Frequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995 (adj. 0.95)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput Protection 208 V 240 V 208 V 240 VAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 15.0 AOutput Overvoltage Protection - Varistor 2 (L1 - L2 / L1 - PE)Operating PerformanceMaximum Efficiency (max) 96.3%Weighted Efficiency (EURO/CEC) - / 96.0%Feed In Power Threshold 24.0 WStand-by Consumption < 8.0 W (1)
CommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface Graphic display EnvironmentalAmbient Temperature Range -25...+60C (-13...+ 140F) Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4XCooling Natural Dimension (H x W x D) 518mm x 367mm x 160mm / 20.4 x 14.4 x 6.3Weight < 17 kg / 37.4 lbMounting System Wall bracketSafetyIsolation Level HF TransformerMarking cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsWith DC Switch UNO-2.0-I-OUTD-S-US UNO-2.5-I-OUTD-S-US
1. Night time consumption < 0.6W
PVI-2000 OUTD OLDProd1_Title
Prod1_Part NosProd1_Prod PicProd1_Back Pic
PVI-2000-OUTD
GENERAL SPECIFICATIONSOUTDOOR MODELS
PVI-2000-OUTD
Features
36 AURORA UNO
Wide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
The transformerless operation of this compact outdoor residential inverter provides an efficiency of 95.5%. The high-speed Maximum Power Point Tracker (MPPT) produces real-time power tracking and improved energy harvesting.
The wide input voltage range makes this inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed as a completely sealed unit to stand withstand the harshest environmental conditions.
This small single string inverter features a front heat sink to keep the unit cleaner and more efficient over time.
37AURORA UNO
PARAMETER PVI-2000-OUTD
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 2100 WNumber of Independent MPPT 1
Maximum DC Input Power for each MPPT (PMPPTmax)2100 W
Linear Derating From MAX to Null [530VVMPPT580V]
MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 210...530 VDC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
Not applicable
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 AMaximum Input Short Circuit Current for each MPPT 12.0 ANumber of DC Inputs Pairs for each MPPT 1DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 2000 WMaximum AC Output Power (Pacmax) 2000 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)
Maximum AC Output Current (Iac,max) 10.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)
Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 2.5 %AC Connection Type Circular connectorOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 16.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (max) 95.5% Weighted Efficiency (EURO/CEC) 94.4% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60C /-13...140F with derating above 40C/104FRelative Humidity 0...100 % condensingNoise Emission < 40 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 420mm x 326mm x 141mm / 16.5 x 12.8 x 5.6Weight < 14.5 kg / 32.0 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS/NZS 3100Grid Standard DK 5940, VDE 0126-1-1, G83/1, AS 4777Available Products VariantsStandard PVI-2000-OUTD
1. The AC voltage range may vary depending on specific country grid standard
2. The Frequency range may vary depending on specific country grid standard
Europe and APAC Version
North America Version
38 AURORA UNO
PVI-3.0-TLPVI-3.6-TLPVI-4.2-TL
GENERAL SPECIFICATIONSOUTDOOR MODELS
PVI-3.0-TL-OUTDPVI-3.0-OUTD-USPVI-3.6-TL-OUTDPVI-3.6-OUTD-USPVI-4.2-TL-OUTDPVI-4.2-OUTD-US
Features
39AURORA UNO
UN
OTR
IO
Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsIntegrated DC disconnect switch in compliance with international Standards (-S Version)RS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
The most common residential inverter is the ideal size for an average-sized family home. This family of single-phase string inverter complements the typical number of rooftop solar panels, allowing home-owners to get the most efficient energy harvesting for the size of the property. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
One of the key benefits of the Uno family of single-phase inverters is the dual input section to process two strings with independent MPPT especially useful for rooftop installations with two diff erent orientations (ie East and West). The high speed MPPT off ers real-time power tracking and improved energy harvesting.
The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Block Diagram and Ef ciency Curves
40 AURORA UNO
BLOCK DIAGRAM OF PVI-3.0-TL-OUTD, PVI-3.6-TL-OUTD AND PVI-4.2-TL-OUTD
PVI-4.2-TL-OUTD PVI-4.2-TL-OUTD
5,00% 10,00% 15,00% 20,00% 25,00% 30,00% 35,00% 40,00% 45,00% 50,00% 55,00% 60,00% 65,00% 70,00% 75,00% 80,00% 85,00% 90,00% 95,00% 100,00%
215 250 300 345 400 480
[%] o
f Rat
ed P
ower
MPPT Voltage [V]
96,8
96,4
96
94,8
94,4
95,2
94
93,6
93,2
92,8
92,4
92
91,6
95,6
96,8
96,4
96,4
96
95,2
96
95,2
96,2
96
94 94
92 92 92
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
[%]
% of rated Output Power
215Vdc
345Vdc
480Vdc
IN1.1(+)
IN1.2(+)*
IN1.1(-)
IN1.2(-)*
IN2.1(+)
IN2.1(-)
IN1.1(+)
IN1.2(+)*
IN1.1(-)
IN1.2(-)*
IN1
IN2
+
-
+
-
IN2.1(+)
IN2.1(-)
STANDARD VERSION
IN1
IN2
+
-
+
-
-S VERSION
IN1
+
-
MPPT 1(DC/DC)
IN2
+
-
MPPT 2(DC/DC)
BULK CAPSINVERTER(DC/AC)
LINEFILTER
GRID PARALLELRELAY
L
N
PE
RESIDUAL CURRENTDETECTION
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
(*)Not available in PVI-3.0-TL-OUTD
41AURORA UNO
PARAMETER PVI-3.0-TL-OUTD PVI-3.6-TL-OUTD PVI-4.2-TL-OUTD
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 3120 W 3750 W 4375 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 2000 W 3000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 160...530 V 120...530 V 140...530 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530VVMPPT580V]
DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
2000 W [200VVMPPT530V] the other channel: Pdcr-2000W
[112VVMPPT530V]
3000 W [190VVMPPT530V] the other channel: Pdcr-3000W [90VVMPPT530V]
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 20.0 A / 10.0 A 32.0 A / 16.0 AMaximum Input Short Circuit Current for each MPPT 12.5 A 20.0 ANumber of DC Inputs Pairs for each MPPT 1 2 for MPPT1 and 1 for MPPT2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 600 VOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 3000 W 3600 W 4200 WMaximum AC Output Power (Pacmax) 3300 W 4000 W 4600 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V(1)Maximum AC Output Current (Iac,max) 14.5 A 17.2 A (2) 20.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (3)Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 3.5 % AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 16.0 A 19.0 A 22.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (max) 96.8% Weighted Efficiency (EURO/CEC) 96.0% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60C /-13...140F with derating above 55C/131FRelative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 617mm x 325mm x 222mm / 24.3 x 12.8 x 8.7Weight 17.5 kg / 38.5 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3
Grid Standard DK 5940, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS 4777
DK 5940, VDE 0126-1-1, G83/1, G59/2(4) , EN 50438, RD1663,
AS 4777
DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777
Available Products VariantsStandard PVI-3.0-TL-OUTD PVI-3.6-TL-OUTD PVI-4.2-TL-OUTDWith DC Switch PVI-3.0-TL-OUTD-S PVI-3.6-TL-OUTD-S PVI-4.2-TL-OUTD-S1. The AC voltage range may vary depending on specific country grid standard2. Maximum Output Current Limited to 16A for G83/1 version3. The Frequency range may vary depending on specific country grid standard4. Ask sales for availability
Block Diagram and Ef ciency Curves
42 AURORA UNO
5,00%
10,00%
15,00%
20,00%
25,00%
30,00%
35,00%
40,00%
45,00%
50,00%
55,00%
60,00%
65,00%
70,00%
75,00%
80,00%
85,00%
90,00%
95,00%
100,00%
215 250 300 345 400 480
[%] o
f Rat
ed P
ower
MPPT Voltage [V]
97,0
96,6
96
94,8
94,4
95,2
94
93,6
93,2
92,8
92,4
92
91,6
95,6
97,0
96,4
96,4
96
95,2
96
95,2
96,2
96
94 94
92 92
92 90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
200 Vdc
340 Vdc
480 Vdc
PVI-4.2-OUTD-US PVI-4.2-OUTD-US
BLOCK DIAGRAM OF PVI-3.0-OUTD, PVI-3.6-OUTD AND PVI-4.2-OUTD FOR NORTH AMERICA
IN1
+
-
IN2
+
-
MPPT 2(DC/DC)
MPPT 1(DC/DC) BULK CAPS
INVERTER(DC/AC)
LINEFILTER
GRID PARALLELRELAY
L1
L2
PE
RESIDUAL CURRENTDETECTION
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
IN1
IN2
+
-
+
-
GROUNDFAULT
DETECTION
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN1
IN2
+
-
+
-
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
STANDARD VERSION -S VERSION
N
IN1.1(+)
IN1.1(-)
IN2.1(+)
IN2.1(-)
43AURORA UNO
TECHNICAL DATA Values PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US
Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277Input Side (DC)Maximum Usable Power for Each Channel W 2000 3000 3000MPPT Voltage Range V 160-530 120-530 140-530 Start- Up Voltage V 200 (adj. 120-350 ) 200 (adj. 120-350 ) 200 (adj. 120-350 )Absolute Maximum Voltage (Vmax) V 600 600 600Maximum Current (Idcmax) for both MPPT in Parallel A 20 32 32Maximum Usable Current per Channel A 10 16 16Number of Wire Landing Terminals per Channel 2 (1 on -S Version) 2 (1 on -S Version) 2 (1 on -S Version)Number of Independent MPPT Channels 2 2 2
Array Wiring Termination Screw terminal block 3 Knock-Outs: 1 or 1 (w/ Ring Reducer)Output Side (AC)Grid Standard 1/2W or Split-/3W 1/2W or Split-/3W 1/2W or Split-/3WNominal Power W 3000 3600 4200Voltage Range (Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304Grid Frequency; Range** Hz 60;(59.3-60.5) 60;(59.3-60.5) 60;(59.3-60.5)Maximum Current (Iac, max) ARMS 14.5 14.5 12 17.2 16 16 20 20 20Power Factor > 0.995 > 0.995 > 0.995 Total Harmonic Distortion At Rated Power % < 2 < 2 < 2EfficiencyMaximum Efficiency % 96.9 97 97CEC Efficiency % 96 96 96Operating Parameters 208 240 277 208 240 277 208 240 277Consumption in Stand By (Night) WRMS < 8.0 < 8.0 < 8.0 Consumption During Operation WRMS 20 20 20Topology Transformerless Transformerless TransformerlessMechanical SpecificationsEnclosure rating NEMA 4X NEMA 4X NEMA 4XCooling Natural Convection Natural Convection Natural Convection
Conduit Connections Trade size KOs: (2eax1/2) and (2ea x 1-1/4,3 places side, front, rear)Trade size KOs: (2eax1/2) and (2ea x
1-1/4,3 places side, front, rear)Trade size KOs: (2eax1/2) and (2ea x
1-1/4,3 places side, front, rear)
Grid Wiring Termination Type Screw Terminal Block Single wire, 900C terminal wiringScrew Terminal Block
Single wire, 900C terminal wiringScrew Terminal Block
Single wire, 900C terminal wiring
Dimensions (W/H/D) in(mm) 12.8 x24.3 x 8.7(325 x617x 222) 12.8 x33.8 x 8.7( 325 x 859 x222 ) -S Version
Unit Weight lb(kg) < 38.5 (17.5) < 47.3(21.3) -S version < 38.5 (17.5)
< 47.3(21.3) -S version < 38.5 (17.5)
< 47.3(21.3) -S versionShipping Weight lbs(kg) < 38.5 (17.5) < 47.3 (21.3) -S version < 38.5 (17.5) < 47.3 (21.3) -S version < 38.5 (17.5) < 47.3 (21.3) -S versionMounting System Wall bracket Wall bracket Wall bracketEnvironmentalAmbient Air Temperature Range F (C) -13...+140 (-25...+60) with derating above 131 (55)Acoustic Noise Emission Level dBA @ 1m < 50 < 50 < 50 Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensingMaximum Operating Altitude without Derating ft(m) 6560 (2000) 6560 (2000) 6560 (2000) Protection DevicesOutputAnti-Islanding Protection According to UL 1741/IEEE 1547 According to UL 1741/IEEE 1547 According to UL 1741/IEEE 1547External AC OCPD Rating ARMS 20 20 15 25 20 20 25 25 25Over-Voltage Protection Type Varistor, 2 (L- N/ L-PE) Varistor, 2 (L- N/ L-PE) Varistor, 2 (L- N/ L-PE)InputReverse Polarity Protection Yes Yes YesMaximum Short Circuit Current Limit per Channel A 12.5 20 20Over-Voltage Protection Type Varistor, 2 for each channel Varistor, 2 for each channel Varistor, 2 for each channelPV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI (Requires Floating Arrays)DC Switch Current Rating (Per Contact) A/V 25 / 600 25 / 600 25 / 600 Isolation Level Transformerless (Floating Array) Transformerless (Floating Array) Transformerless (Floating Array)Safety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Safety Approval CCSAUS CCSAUS CCSAUSFeatures- CommunicationUser-Interface (Display) 16 characters x 2 lines LCD display 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayRemote Monitoring (1xRS485 incl.) AURORA-UNIVERSAL (opt.) AURORA-UNIVERSAL (opt.) AURORA-UNIVERSAL (opt.)Wired Local Monitoring (1xRS485 incl.) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)Standard Warranty Years 5 5 5Available ModelsStandard- No switchbox-Floating Array PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US DC Switch Option - Floating Array PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US PVI-4.2-OUTD-S-US
*All data is subject to change without notice** Adjustable low trip point to 57Hz. Contact manufacturer for details
Europe and APAC Version
North America Version
44 AURORA UNO
PVI-3.8-IPVI-4.6-I
GENERAL SPECIFICATIONSOUTDOOR MODELS
PVI-3.8-I-OUTDPVI-3.8-I-OUTD-US
PVI-4.6-I-OUTDPVI-4.6-I-OUTD-US
Features
45AURORA UNO
UN
OTR
IO
Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputNight Wake up button to access energy harvesting data and error logDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
This isolated inverter is optimized for use in residential applications requiring PV array groun-ding, such as some thin-film modules. This inverter has also been designed to serve all countries and regions with specific field-configurable set-ups available for all major country grid codes and display languages.
The 3.8 and 4.6kW isolated inverters have all the usual Aurora benefits including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as regular high performance efficiencies of up to 96.9%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.
Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Block Diagram and Ef ciency Curves
46 AURORA UNO
PVI-3.8-I-OUTD PVI-4.6-I-OUTD
BLOCK DIAGRAM OF PVI-3.8-I-OUTD AND PVI-4.6-I-OUTD
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
200 Vdc
340 Vdc
416 Vdc
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
200 Vdc
340 Vdc
416 Vdc
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
RS485
ALARM
IN1
+
-
MPPT 1(DC/DC)
IN2
+
-
MPPT 2(DC/DC)
BULK CAPSINVERTER(DC/AC)
LINEFILTER
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
GRID PARALLELRELAY
L
N
PE
HFTRANSFORMER
HFTRANSFORMER
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN1
IN2
+
-
+
-
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
STANDARD VERSION
IN1
IN2
+
-
+
-
-S VERSION
+ T/R
- T/R
RTN
+ R
- R
N.C
N.O
C
REMOTE CONTROL
47AURORA UNO
PARAMETER PVI-3.8-I-OUTD PVI-4.6-I-OUTD
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 4000 W 4800 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 3000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 160...470 V 180...470 V
DC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470VVMPPT520V]Linear Derating From MAX to Null
[470VVMPPT520V]DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
3000 W [210VVMPPT470V] the other channel: Pdcr-3000W [90VVMPPT470V]
3000 W [210VVMPPT470V] the other channel: Pdcr-3000W [130VVMPPT470V]
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 25.0 A / 12.5 A 28.0 A / 14.0 AMaximum Input Short Circuit Current for each MPPT 22.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 3800 W 4600 WMaximum AC Output Power (Pacmax) 4200 W 5000 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)Maximum AC Output Current (Iac,max) 18.2 A (2) 22.5 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (3)Nominal Power Factor (Cosphiac,r) > 0.995 (adj. 0.95)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 20.0 A 25.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (max) 96.8%Weighted Efficiency (EURO/CEC) - / 96.5% Feed In Power Threshold 24.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental
Ambient Temperature Range -25...+60C (-13...+ 140F) -25...+60C (-13...+ 140F)with derating above 50C (122F)Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 712mm x 325mm x 222mm / 28.0 x 12.8 x 8.7Weight < 24.0 kg / 53.0 lbMounting System Wall bracketSafetyIsolation Level HF TransformerMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G83/1, G59/2, EN 50438, RD1663, AS 4777Available Products VariantsStandard PVI-3.8-I-OUTD PVI-4.6-I-OUTDWith DC Switch PVI-3.8-I-OUTD-S PVI-4.6-I-OUTD-S1. The AC voltage range may vary depending on specific country grid standard2. Maximum Output Current Limited to 16A for G83/1 version3. The Frequency range may vary depending on specific country grid standard4. Independent MPPT just with negative ground
Block Diagram and Ef ciency Curves
48 AURORA UNO
PVI-3.8-I-OUTD-US PVI-4.6-I-OUTD-US
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
200 Vdc
340 Vdc
416 Vdc
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
200 Vdc
340 Vdc
416 Vdc
BLOCK DIAGRAM OF PVI-3.8-I-OUTD AND PVI-4.6-I-OUTD FOR NORTH AMERICA
IN1
+
-
IN2
+
-
MPPT 2(DC/DC)
MPPT 1(DC/DC) BULK CAPS
INVERTER(DC/AC)
LINEFILTER
GRID PARALLELRELAY
L1
L2
PE
RESIDUAL CURRENTDETECTION
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
IN1
IN2
+
-
+
-
GROUNDFAULT
DETECTION
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN1
IN2
+
-
+
-
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
STANDARD VERSION -S VERSION-NG
N
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
HFTRANSFORMER
HFTRANSFORMER
* if -PG version, switch is on negative polarity.
*
*
49AURORA UNO
TECHNICAL DATA Values PVI-3.8-I-OUTD-US PVI-4.6-I-OUTD-US
Rated Grid AC Voltage V 208 240 277 208 240 277Input Side (DC)Maximum Usable Power for Each Channel W 3000 3000MPPT Voltage Range V 200-470 200-470Start- Up Voltage V 200 (adj. 120-350 ) 200 (adj. 120-350 )Absolute Maximum Voltage (Vmax) V 520 520Maximum Current (Idcmax) for both MPPT in Parallel A 25 28Maximum Usable Current per Channel A 12.5 14Number of Wire Landing Terminals per Channel 2(standard version) or 1(-S version) 2(standard version) or 1(-S version)Number of Independent MPPT Channels 2 2
Array Wiring Termination Screw terminal block 3 Knock-Outs: 3/4 or 1 (w/ Ring Reducer)Screw terminal block
3 Knock-Outs: 3/4 or 1 (w/ Ring Reducer)Output Side (AC)Grid Standard 1/2W or Split-/3W 1/2W or Split-/3WNominal Power W 3800 4600Voltage Range (Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency; Range** Hz 60;(59.3-60.5) 60;(59.3-60.5)Maximum Current (Iac, max) A 16 23 20 20Power Factor > 0.995 > 0.995 Total Harmonic Distortion At Rated Power % < 2 < 2EfficiencyMaximum Efficiency % 96.9 96.9CEC Efficiency % 96 96.5 96.5 96 96.5 96.5Operating ParametersConsumption in Stand By (Night) WRMS < 8.0 < 8.0 Consumption During Operation WRMS 24 24Topology Isolated - HF Transformer Uses ground referenced arraysMechanical SpecificationsEnclosure rating NEMA 4X NEMA 4XCooling Natural Convection Natural Convection
Conduit Connections Trade size KOs: 3/4 or 1 (w/ Ring Reducer); 3 places (side, front, rear) 2ea x 1/2 KO for monitoringGrid Wiring Termination Type Screw terminal block , 3 Knock-Outs: 3/4 or 1 (w/ Ring Reducer)Dimensions (W/H/D) in/(mm) 12.8 x 28.0 x 8.7(325 x712 x 222) 12.8 x 28.0 x 8.7(325 x712 x 222)Unit Weight lb/(kg) < 53.0 /24.0, < 61.0 /28.0 -S version < 53.0 /24.0, < 61.0 /28.0 -S versionShipping Weight lbs(kg) 66 (30) S-version 72 (32.7) 66 (30), S-version 72 (32.7)Mounting System Wall bracket Wall bracketEnvironmentalAmbient Air Temperature Range C (F) -25...+60 (-13...+140) with derating above 50 (122) -25...+60 (-13...+140) with derating above 50 (122)Acoustic Noise Emission Level db (A) @1m < 50 < 50Relative Humidity %RH 0-100 condensing 0-100 condensingMaximum Operating Altitude without Derating ft(m) 6560 (2000) 6560(2000)Protection Devices OutputAnti-Islanding Protection According to UL1741/NEC690.5 According to UL1741/NEC690.5External AC OCPD Rating ARMS 20 30 25 25Over-Voltage Protection Type Varistor, 2 (L - N / L - PE) Varistor, 2 (L - N / L - PE)InputReverse Polarity Protection Yes YesMaximum Short Circuit Current Limit per Channel A 15.6 17Over-Voltage Protection Type Varistor, 2 for each channel Varistor, 2 for each channelPV Array Ground Fault Detection According to local standard UL174/NEC696.5DC Switch Current Rating (Per Contact) A/V 25 / 600 25 / 600 Ground Fault Detector Fuse Size/ Type A/V mm 1A/600V 10mmx38mm 1A/600V 10mmx38mmOptional String Combiner Fuse Size/Type A/V mm 15A/600V 10mmx38mm 15A/600V 10mmx38mmIsolation Level High-Frequency Transformer High-Frequency TransformerSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Safety Approval cCSAus cCSAusFeatures- CommunicationUser-Interface (Display) 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayRemote Monitoring (1xRS485 incl.) AURORA-UNIVERSAL (opt.) AURORA-UNIVERSAL (opt.)Wired Local Monitoring (1xRS485 incl.) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)Standard Warranty Years 5 5Available ModelsStandard - Positive Ground Standard - Positive Ground PVI-3.8-I-OUTD-US-PG PVI-4.6-I-OUTD-US-PGStandard - Negative Ground Standard - Negative Ground PVI-3.8-I-OUTD-US-NG PVI-4.6-I-OUTD-US-NGWith DC Switch- Positive Ground With DC Switch- Positive Ground PVI-3.8-I-OUTD-US-S-PG PVI-4.6-I-OUTD-US-S-PGWith DC Switch- Negative Ground With DC Switch- Negative Ground PVI-3.8-I-OUTD-US-S-NG PVI-4.6-I-OUTD-US-S-NG
*All data is subject to change without notice** Adjustable low trip point to 57Hz. Contact manufacturer for details
Europe and APAC Version
North America Version
50 AURORA UNO
PVI-5000-TLPVI-6000-TL
GENERAL SPECIFICATIONSOUTDOOR MODELS
PVI-5000-TL-OUTDPVI-6000-TL-OUTD
PVI-5000-OUTD-USPVI-6000-OUTD-US
Features
51AURORA UNO
UN
OTR
IO
Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW.
This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.1%.
The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Block Diagram and Ef ciency Curves
52 AURORA UNO
BLOCK DIAGRAM OF PVI-5000-TL-OUTD AND PVI-6000-TL-OUTD
PVI-5000-TL-OUTD PVI-6000-TL-OUTD
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
250 Vdc
345 Vdc
480 Vdc
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
250 Vdc
345 Vdc
480 Vdc
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN1
IN2
+
-
+
-
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
STANDARD VERSION
IN1
IN2
+
-
+
-
-S VERSION
IN1
+
-
MPPT 1(DC/DC)
IN2
+
-
MPPT 2(DC/DC)
BULK CAPSINVERTER(DC/AC)
LINEFILTER
GRID PARALLELRELAY
L
N
PE
RESIDUAL CURRENTDETECTION
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
53AURORA UNO
PARAMETER PVI-5000-TL-OUTD PVI-6000-TL-OUTD
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 4800 W 6200 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 4000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 150...530 V 180...530 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530VVMPPT580V]
DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
4000 W [220VVMPPT530V] the other channel: Pdcr-4000W [90VVMPPT530V]
4000 W [220VVMPPT530V] the other channel: Pdcr-4000W [120VVMPPT530V]
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 36.0 A / 18.0 AMaximum Input Short Circuit Current for each MPPT 22.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 5000 W 6000 WMaximum AC Output Power (Pacmax) 5000 W (3) 6000 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)
Maximum AC Output Current (Iac,max) 25.0 A 30.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)
Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 3.5%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 32.0 A 40.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (max) 97.0%Weighted Efficiency (EURO/CEC) 96.4% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60C (-13...+ 140F) with derating above 50C (122F)Relative Humidity 0...100% condensingNoise Emission
Block Diagram and Ef ciency Curves
54 AURORA UNO
PVI-6000-OUTD-US PVI-6000-OUTD-US
90
91
92
93
94
95
96
97
98
99
100
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Eci
ency
, %
% of Rated Output Power
250 Vdc
345 Vdc
480 Vdc
250
300
345
400
480
10% 20% 30% 50% 75% 100%
96,8
96,5
96,2
95,9
95,6
95,3
95 94,7
94,4 94,1
93,8
93,5
93,2
92,9
92,6
97,1
97,1
96,8
96,5
96,2
95,9
96,5
96,2
95
[%] o
f Rat
ed P
ower
MPPT Voltage [V]
BLOCK DIAGRAM OF PVI-5000-OUTD AND PVI-6000-OUTD FOR NORTH AMERICA
IN1
+
-
MPPT 1(DC/DC)
IN2
+
-
MPPT 2(DC/DC)
BULK CAPSINVERTER(DC/AC)
LINEFILTER
GRID PARALLELRELAY
L1
L2
PE
RESIDUAL CURRENTDETECTION
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
IN1(+)
IN1(-)
IN1
IN2
+
-
+
-
IN2(+)
IN2(-)
GROUNDFAULT
DETECTION
-S VERSION
N
55AURORA UNO
TECHNICAL DATA Values PVI-5000-OUTD-US PVI-6000-OUTD-US
Rated Grid AC Voltage V 208 240 277 208 240 277Input Side (DC)Maximum Usable Power for Each Channel W 4000 4000MPPT Voltage Range V 200-530 200-530Start- Up Voltage V 200 (adj. 120-350 ) 200 (adj. 120-350 )Absolute Maximum Voltage (Vmax) V 600 600Maximum Current (Idcmax) for both MPPT in Parallel A 36 36Maximum Usable Current per Channel A 18 18Number of Wire Landing Terminals per Channel 1 1Number of Independent MPPT Channels 2 2
Array Wiring Termination Screw terminal block 3 Knock-Outs: 1 or 1 (w/ Ring Reducer.)Screw terminal block
3 Knock-Outs: 1 or 1 (w/ Ring Reducer.)Output Side (AC)Grid Standard 1/2W or Split-/3W 1/2W or Split-/3WNominal Power W 5000 6000Voltage Range (Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency; Range** Hz 60;(59.3-60.5) 60;(59.3-60.5)Maximum Current (Iac, max) A 27 23 20 30 28 24Power Factor > 0.995 > 0.995 Total Harmonic Distortion At Rated Power % < 2 < 2EfficiencyMaximum Efficiency % 97.1 97.1CEC Efficiency % 96 96.5 96.5 96 96.5 96.5Operating ParametersConsumption in Stand By (Night) WRMS < 8.0 < 8.0 Consumption During Operation WRMS 20 20Topology Transformerless TransformerlessMechanical SpecificationsEnclosure rating NEMA 4 NEMA 4Cooling Natural Convection Natural Convection
Conduit Connections Trade size KOs: (2eax1/2) and (2ea x 1-1/4,3 places side, front, rear) Trade size KOs: (2eax1/2) and
(2ea x 1-1/4,3 places side, front, rear)
Grid Wiring Termination Type Screw Terminal Block Single wire, 900C terminal wiringScrew Terminal Block
Single wire, 900C terminal wiringDimensions (W/H/D) in(mm) 12.8 x41.4x 8.7( 325 x1052 x 222 ) 12.8 x41.4x 8.7( 325 x1052 x 222 )Unit Weight lb(kg) < 59.5 (27.0) < 59.5 (27.0) Shipping Weight lbs (kg) 78( 35.4) 78 (35.4) Mounting System Wall bracket Wall bracketEnvironmentalAmbient Air Temperature Range F(C) -13...+140 (-25...+60) with derating above 122 (50) -13...+140 (-25...+60) with derating above 122 (50) Accoustic Noise Emission Level db A@ 1 m < 50 < 50Relative Humidity %RH 0-100 condensing 0-100 condensingMaximum Operating Altitude without Derating ft(m) 6560 (2000 ) 6560 (2000 )Protection Devices OutputAnti-Islanding Protection According to UL 1741/IEEE 1547 According to UL 1741/IEEE 1547 External AC OCPD Rating ARMS 35 30 25 40 35 30Over-Voltage Protection Type Varistor, 2(L-N/L-PE) Varistor, 2(L-N/L-PE) InputReverse Polarity Protection Yes YesMaximum Short Circuit Current Limit per Channel A 22 22Over-Voltage Protection Type Varistor, 2 for each channel Varistor, 2 for each channel
PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI (Requires Floating Arrays)Pre start-up Riso and dynamic GFDI
(Requires Floating Arrays)DC Switch Current Rating (Per Contact) A/V 25 / 600 25 / 600
Isolation Level Transformerless (Floating Array) Transformerless (Floating Array)Safety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Safety Approval CCSAUS CCSAUSFeatures- CommunicationUser-Interface (Display) 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayRemote Monitoring (1xRS485 incl.) AURORA-UNIVERSAL (opt.) AURORA-UNIVERSAL (opt.)Wired Local Monitoring (1xRS485 incl.) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.) PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)Standard Warranty Years 5 5 Available ModelsStandard- With DC Switch- Floating Array PVI-5000-OUTD-US PVI-6000-OUTD-US
*All data is subject to change without notice** Adjustable low trip point to 57Hz. Contact manufacturer for details
56 AURORA TRIO
TRIO
UN
OTR
IO
57AURORA TRIO
Europe and APAC Version
North America Versions
-S2 version
-S version
58 AURORA TRIO
PVI-10.0-IPVI-12.0-I
GENERAL SPECIFICATIONSOUTDOOR MODELS
PVI-10.0-I-OUTD-400PVI-10.0-I-OUTD-US-208PVI-10.0-I-OUTD-US-480PVI-10.0-I-OUTD-CAN-600PVI-12.0-I-OUTD-400PVI-12.0-I-OUTD-US-480PVI-12.0-I-OUTD-CAN-600
Features
UN
OTR
IO
59AURORA TRIO
Electrolyte-free power converter to further increase the life expectancy and long term reliabilityTrue three-phase bridge topology for DC/AC output converterEach inverter is set on specific grid codes which can be selected in the fieldNight Wake up button to access energy harvesting data and error logDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsIntegrated DC disconnect switch in compliance with international Standards (-S and -S2 version)RS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This device has two independent MPPTs and efficiency ratings of up to 97.3%.
The input voltage range makes the inverter suitable to installations with reduced string size. The HF isolation allows positive or negative ground configuration.
It is available with an optional fully-integrated DC and AC disconnect (-S2 version).The unit is free of electrolytic capacitors, leading to a longer product lifetime.
Block Diagram and Ef ciency Curves
60 AURORA TRIO
PVI-10.0-I PVI-12.0-I
90
91
92
93
94
95
96
97
98
99
100
Eci
ency
, %
% of Rated Output Power
220 Vdc
362 Vdc
416 Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
90
91
92
93
94
95
96
97
98
99
100
Eci
ency
, %
% of Rated Output Power
250 Vdc
370 Vdc
416 Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
BLOCK DIAGRAM OF PVI-10.0-I AND PVI-12.0-I FOR NORTH AMERICA
IN1
+
-
MPPT 1(DC/DC)
IN2
+
-
MPPT 2(DC/DC)
BULK CAPSINVERTER(DC/AC)
LINEFILTER
DC/DCDSP
CONTR.
DC/ACDSP
CONTR.
P
CONTROL CIRCUIT
GRID PARALLELRELAY
L1
L2
L3
N
PE
GROUNDFAULT
DETECTION
HFTRANSFORMER
HFTRANSFORMER
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN1
IN2
+
-
+
-
IN2.1(+)
IN1.2(+)
IN2.1(-)
IN2.2(-)
STANDARD VERSION
IN1
IN2
+
-
+
-
-S VERSION
RS485
+ T/R
- T/R
RTN
REMOTE CONTROL
+ R
- R
ALARM
N.C
N.O
C
-S2 VERSION (5)
L1 L1, S
L2 L2, S
L3 L3, S
N N, S
PE
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
(1)
(1)
IN1
IN2
+
-
+
-
-S2 VERSION-NG
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
IN1.3(+)
IN1.3(-)
(1)
(1)
(1) if -PG version switch and fuses are on negative polarity.
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
IN2.3(+)
IN2.3(-)
(1)
(1)
(5) for PVI-10.0-I-OUTD-208 or connectionfor PVI-10.0-I-OUTD-480 connection only
61AURORA TRIO
PARAMETER PVI-10.0-I-OUTD-400 PVI-12.0-I-OUTD-400
Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 10500 W 12300 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 6800 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 220...470 V 250...470 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470VVMPPT520V]
DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example
6800 W [285VVMPPT470V] the other channel: Pdcr-6800W
[155VVMPPT470V]
6800 W [275VVMPPT470V] the other channel: Pdcr-6800W [220VVMPPT470V]
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 48.0 A / 24.0 A 50.0 A / 25.0 AMaximum Input Short Circuit Current for each MPPT 29.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 32 A / 600 VFuse Rating (-FS Version) Not applicableOutput SideAC Grid Connection Type Trifase (/Y)Rated AC Power (Pacr) 10000 W 12000 WMaximum AC Output Power (Pacmax) 11000 W (3) 12500 WRated AC Grid Voltage (Vac,r) 400 VAC Voltage Range 320...480 V (1)Maximum AC Output Current (Iac,max) 16.0 A 18.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)Nominal Power Factor (Cosphiac,r) > 0.995 (adj. 0.9)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 20.0 AOutput Overvoltage Protection - Varistor 3 plus gas arresterOperating PerformanceMaximum Efficiency (max) 97.3%Weighted Efficiency (EURO/CEC) 97.0% / - Feed In Power Threshold 30 WStand-by Consumption < 8 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental
Ambient Temperature Range -25...+60C /-13...140F with derating above 50C/122F-25...+60C /-13...140F
with derating above 45C/113FRelative Humidity 0...100% condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 716mm x 645mm x 222mm / 28.2 x 25.4 x 8.7Weight < 45.8 kg / 99.0 lbMounting System Wall bracketSafetyIsolation Level HF transformerMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777Available Products VariantsStandard PVI-10.0-I-OUTD-400 PVI-12.0-I-OUTD-400With DC Switch PVI-10.0-I-OUTD-S-400 PVI-12.0-I-OUTD-S-4001. The AC voltage range may vary depending on specific country grid standard2. The Frequency range may vary depending on specific country grid standard3. Limited to 10000 W for Benelux4. Independent MPPT just with negative ground
TECHNICAL DATA Values PVI-10.0-I-OUTD-US
Rated Grid AC Voltage V 208 480 600Input Side (DC)Maximum Usable Power for Each Channel W 6800MPPT Voltage Range V 220-470Start- Up Voltage V Default: 200 (Adj. 120-350)Absolute Maximum Voltage (Vmax) V 520Maximum Current (Idcmax) for both MPPT in Parallel A 48Maximum Usable Current per Channel A 24Number of Wire Landing Terminals per Channel Standard version: 2, Switch box version: 2 or 3Number of Independent MPPT Channels Two; programmable as a single paralleled inputArray Wiring Termination Terminal block, pressure clamp, 90 C termimalsOutput Side (AC)Grid Standard 3-phase/3W or 3-phase/4W/Y (programmable)Nominal Power W 10000Voltage Range (Vmin-Vmax) V 183-228 422-528 528-660Grid Frequency; Range** Hz 60; (59.3-60.5)Maximum Current (Iac, max) A 30.0 14.0 10.6Power Factor >0.995 (+/-0.9)Total Harmonic Distortion At Rated Power % THD
TECHNICAL DATA Values PVI-12.0-I-OUTD
Rated Grid AC Voltage V 480 600Input Side (DC)Maximum Usable Power for Each Channel W 6800 6800MPPT Voltage Range V 250-470 250-470Start- Up Voltage V Default: 200 (Adj. 120-350)Absolute Maximum Voltage (Vmax) V 520 520Maximum Current (Idcmax) for both MPPT in Parallel A 50 50Maximum Usable Current per Channel A 25 25Number of Wire Landing Terminals per Channel Standard version: 2 Switch box version: 2 or 3Number of Independent MPPT Channels Two; programmable as a single paralleled inputArray Wiring Termination Terminal block, pressure clamp, 90 C termimalsOutput Side (AC)Grid Standard 3-phase/3W or 3-phase/4W/Y (programmable)Nominal Power W 12000Voltage Range (Vmin-Vmax) V 422-528 528-660Grid Frequency; Range** Hz 60; (59.3-60.5) 60; (59.3-60.5)Maximum Current (Iac, max) A 16.0 12.8Power Factor >0.995 (+/-0.9) >0.995 (+/-0.9)Total Harmonic Distortion At Rated Power % THD
64 AURORA TRIO
PVI-10.0-TLPVI-12.5-TL
GENERAL SPECIFICATIONSOUTDOOR MODELS
PVI-10.0-TL-OUTDPVI-10.0-TL-OUTD-SPVI-10.0-TL-OUTD-FS
PVI-12.5-TL-OUTDPVI-12.5-TL-OUTD-SPVI-12.5-TL-OUTD-FS
Features
UN
OTR
IO
65AURORA TRIO
Electrolyte-free power converter to further increase the life expectancy and long term reliabilityTrue three-phase bridge topology for DC/AC output converterEach inverter is set on specific grid codes which can be selected in the fieldDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energyharvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsIntegrated DC disconnect switch in compliance with international Standards (-S Version)RS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
The three-phase 10.0 and 12.5 kW non-isolated inverter is an industry leader.
Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This transformerless device has two independent MPPTs and efficiency ratings of up to 97.7%.
The wide input voltage range makes the inverter suitable to low power installations with reduced string size. It is available with an optional fully-integrated DC switch, fuse and remote controlled DC disconnect function. The unit is free of electrolytic capacitors, leading to a longer product lifetime.