1
Weights excluding cable TOK4-P TOK2-65 TOK2-65T 0.15 to 0.75kW 1.5kW 2.2 to 3.7kW Model Model d A B H W1 W2 Material Length 100-120V Cores × mm 2 Outer Dia. mm Cores × mm 2 Outer Dia. mm 200-240V m Model Applicable Motor Output Discharge Bore Motor Output Phase Starting Method Solids Passage Dry Weight kg Model Standard Automatic Standard Auto-alternation Auto & Auto-alternation PVC Unit: mm Pumping Fluid Discharge Connection Pump Discharge Bore 50 80 40 mm Motor Sewage, Wastewater, and Water carrying Solid Matters 0 to 40℃ Vortex Double Mechanical Seal ( with Oil Lifter ) Double-shielded Ball Bearing Glass-fiber Reinforced Resin Glass-fiber Reinforced Resin Silicon Carbide Dry-type Submersible Induction Motor, 2-pole Class E Single-phase ( suffix "S" ) Three-phase Capacitor Run ( single-phase only ) Direct on Line Circle Thermal Protector Miniature Thermal Protector ( 40PU2.15S, 40PU2.25S & 50PU2.4S only ) Liquid Paraffin ( ISO VG32 ) 304 Stainless Steel 420 Stainless Steel ( 0.15kW only ) 304 Stainless Steel PVC Screwed Flange Impeller Shaft Seal Bearing Impeller Casing Shaft seal Frame Shaft Cable Type of Fluid Fluid Temperature Structure Materials Type, Pole Insulation Phase Starting Method Protection Device ( Built-in ) Lubricant Materials 3 × 1.25 3 × 1.25 3 × 1.25 3 × 2.0 40PU2.15S 40PU2.25S 50PU2.4S 50PU2.75S 10.1 10.1 10.1 10.9 3 × 1.25 3 × 1.25 3 × 1.25 3 × 1.25 10.1 10.1 10.1 10.1 5 Model Material Length 200-240V Cores × mm 2 Outer Dia. mm Cores × mm 2 Outer Dia. mm 380-600V m PVC 4 × 1.25 4 × 1.25 4 × 1.25 4 × 1.25 4 × 1.25 4 × 2.0 4 × 3.5 40PU2.15 40PU2.25 50PU2.4 50PU2.75 80PU21.5 80PU22.2 80PU23.7 11.1 11.1 11.1 11.1 11.1 11.8 13.9 4 × 1.25 4 × 1.25 4 × 1.25 4 × 1.25 4 × 1.25 4 × 1.25 4 × 2.0 11.1 11.1 11.1 11.1 11.1 11.1 11.8 6 40 40 40 40 50 50 50 50 80 80 80 40PU2.15S 40PU2.15 40PU2.25S 40PU2.25 50PU2.4S 50PU2.4 50PU2.75S 50PU2.75 80PU21.5 80PU22.2 80PU23.7 40PUA2.15S 40PUA2.15 40PUA2.25S 40PUA2.25 50PUA2.4S 50PUA2.4 50PUA2.75S 50PUA2.75 80PUA21.5 80PUA22.2 80PUA23.7 40PUW2.15S 40PUW2.15 40PUW2.25S 40PUW2.25 50PUW2.4S 50PUW2.4 50PUW2.75 80PUW21.5 80PUW22.2 80PUW23.7 0.15 0.15 0.25 0.25 0.4 0.4 0.75 0.75 1.5 2.2 3.7 Capacitor Run D.O.L. Capacitor Run D.O.L. Capacitor Run D.O.L. Capacitor Run D.O.L. D.O.L. D.O.L. D.O.L. 35 35 35 35 35 35 35 35 46 46 46 6.1 5.6 7.1 6.1 7.1 7.0 8.9 8.3 16.0 22.0 27.0 6.7 6.3 7.8 6.8 7.8 7.7 9.5 9.0 16.9 23.0 28.0 Single Three Single Three Single Three Single Three Three Three Three kW mm mm 40PU2.15S 40PU2.15 40PU2.25S 40PU2.25 50PU2.4S 50PU2.4 50PU2.75S 50PU2.75 80PU21.5 80PU22.2 80PU23.7 40 40 40 40 50 50 50 50 80 80 80 225 225 236 236 236 236 236 236 295 311 311 154 154 162 162 162 162 162 162 196 212 212 377 377 360 349 360 360 380 374 475 583 618 340 340 325 310 325 325 345 335 430 520 555 105 105 110 110 110 110 110 110 150 155 155 B A C.W.L.: Continuous Running Water Level L.W.L.: Lowest Running Water Level L.W.L. C.W.L. d W2 W1 H 10 15 20 25 5 0 0 0.2 0.4 0.6 0.8 1.0 10 15 20 25 27 27 5 0.2 0.4 0.6 0.8 1.0 Total Head (m) Total Head (m) Capacity (m /min) 3 Capacity (m /min) 3 S.S. 3000min - 1 S.S. 3600min - 1 80PU23.7 80PU22.2 80PU22.2 80PU21.5 80PU21.5 50PU2.75 ( S ) 50PU2.75 ( S ) 50PU2.4 ( S ) 50PU2.4 ( S ) 40PU2.25 ( S ) 40PU2.25 ( S ) 40PU2.15 ( S ) 40PU2.15 ( S ) 80PU23.7 80PU23.7 80PU22.2 80PU22.2 80PU21.5 80PU21.5 50PU2.75 ( S ) 50PU2.75 ( S ) 50PU2.4 ( S ) 50PU2.4 ( S ) 40PU2.25 ( S ) 40PU2.25 ( S ) 40PU2.15 ( S ) 40PU2.15 ( S ) 50 Hz 60 Hz Standard, Automatic and Auto-alternation models have the identical performance. 0 0 Guide Rail Fitting Model Selection Performance Curves Dimensions Cabtyre Cables The PU-series is a vortex pump designed for handling raw sewage, wastewater, Industrial and commercial sump pump applications. The solid handling design provides practically unchokable operation in sewage pumping. Since the pump is made of special resin and stainless steel, it is corrosion-resistant and lightweight. Submersible Sewage Pumps Accessories Duckfoot Bend Guide Hook Guide Support with Bolts & Nuts Lifting Chain with Shackles ( 4m for TOK4-P, 5m for TOK2-65 / 65T ) TOK Application Table Applications Draining sewage from factory, residence, hotel, restaurant, etc. Pumping rainwater and springwater at a place where foreign objects are likely to run into the water Transferring wastewater between the tanks at small-scale treatment facility Major Components & Specifications Single-phase Three-phase 6 5

PU Sewage Pump - Aussie Pumps

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

• Weights excluding cable

TOK4-PTOK2-65TOK2-65T

0.15 to 0.75kW1.5kW2.2 to 3.7kW

Model

Model d A B H W1 W2

MaterialLength100-120VCores ×

mm2Outer Dia.

mmCores ×

mm2Outer Dia.

mm

200-240V

m

Model Applicable Motor Output

DischargeBore

MotorOutput Phase Starting

MethodSolids

Passage Dry Weight kgModel

Standard Automatic StandardAuto-alternation Auto &Auto-alternation

PVC

Unit: mm

PumpingFluid

Discharge Connection

Pump

Discharge Bore 50 8040mm

Motor

Sewage, Wastewater, andWater carrying Solid Matters0 to 40℃VortexDouble Mechanical Seal (with Oil Lifter)Double-shielded Ball BearingGlass-fiber Reinforced ResinGlass-fiber Reinforced ResinSilicon CarbideDry-type SubmersibleInduction Motor, 2-poleClass ESingle-phase (suffix "S")Three-phaseCapacitor Run (single-phase only)Direct on LineCircle Thermal ProtectorMiniature Thermal Protector(40PU2.15S, 40PU2.25S & 50PU2.4S only)

Liquid Paraffin (ISO VG32)304 Stainless Steel420 Stainless Steel (0.15kW only)304 Stainless SteelPVCScrewed Flange

ImpellerShaft SealBearingImpellerCasingShaft seal

Frame

Shaft

Cable

Type of Fluid

Fluid Temperature

Structure

Materials

Type, Pole

Insulation

Phase

Starting Method

Protection Device(Built-in)

Lubricant

Materials

3 × 1.253 × 1.253 × 1.253 × 2.0

40PU2.15S 40PU2.25S 50PU2.4S 50PU2.75S

10.110.110.110.9

3 × 1.253 × 1.253 × 1.253 × 1.25

10.110.110.110.1

5

Model MaterialLength200-240VCores ×

mm2Outer Dia.

mmCores ×

mm2Outer Dia.

mm

380-600V

m

PVC

4 × 1.254 × 1.254 × 1.254 × 1.254 × 1.254 × 2.04 × 3.5

40PU2.15 40PU2.25 50PU2.4 50PU2.75 80PU21.5 80PU22.2 80PU23.7

11.111.111.111.111.111.813.9

4 × 1.254 × 1.254 × 1.254 × 1.254 × 1.254 × 1.254 × 2.0

11.111.111.111.111.111.111.8

6

4040404050505050808080

40PU2.15S40PU2.1540PU2.25S40PU2.2550PU2.4S50PU2.450PU2.75S50PU2.7580PU21.580PU22.280PU23.7

40PUA2.15S40PUA2.1540PUA2.25S40PUA2.2550PUA2.4S50PUA2.450PUA2.75S50PUA2.7580PUA21.580PUA22.280PUA23.7

40PUW2.15S40PUW2.1540PUW2.25S40PUW2.2550PUW2.4S50PUW2.4

50PUW2.7580PUW21.580PUW22.280PUW23.7

0.150.150.250.250.40.40.750.751.52.23.7

Capacitor RunD.O.L.

Capacitor RunD.O.L.

Capacitor RunD.O.L.

Capacitor RunD.O.L.D.O.L.D.O.L.D.O.L.

3535353535353535464646

6.15.67.16.17.17.08.98.3

16.022.027.0

6.76.37.86.87.87.79.59.0

16.923.028.0

SingleThreeSingleThreeSingleThreeSingleThreeThreeThreeThree

kW mmmm

40PU2.15S40PU2.1540PU2.25S40PU2.2550PU2.4S50PU2.450PU2.75S50PU2.7580PU21.580PU22.280PU23.7

4040404050505050808080

225225236236236236236236295311311

154154162162162162162162196212212

377377360349360360380374475583618

340340325310325325345335430520555

105105110110110110110110150155155

B

A

C.W.L.: Continuous Running Water LevelL.W.L.: Lowest Running Water Level

L.W.L.

C.W.L.

d

W2

W1 H

10

15

20

25

5

0 00.2 0.4 0.6 0.8 1.0

10

15

20

2527 27

5

0.2 0.4 0.6 0.8 1.0

Tota

l Hea

d (m

)

Tota

l Hea

d (m

)

Capacity (m /min)3 Capacity (m /min)3

S.S. 3000min-1 S.S. 3600min-1

80PU23.7

80PU22.2

80PU22.2

80PU21.5

80PU21.5

50PU2.75 (S )

50PU2.75 (S )

50PU2.4(S)

50PU2.4(S)40PU2.25(S)

40PU2.25(S)40PU2.15(S)

40PU2.15(S)

80PU23.7

80PU23.780PU22.2

80PU22.280PU21.5

80PU21.5

50PU2.75(S)

50PU2.75(S)

50PU2.4(S)

50PU2.4(S)40PU2.25(S)

40PU2.25(S)40PU2.15(S)

40PU2.15(S)

50Hz

60Hz

Standard, Automatic and Auto-alternation models have the identical performance.

0 0

Guide Rail Fitting

Model Selection

Performance Curves

Dimensions

Cabtyre Cables

The PU-series is a vortex pump designed for handling raw sewage, wastewater, Industrial and commercial sump pump applications. The solid handling design provides practically unchokable operation in sewage pumping. Since the pump is made of special resin and stainless steel, it is corrosion-resistant and lightweight.

Submersible Sewage Pumps

Accessories• Duckfoot Bend• Guide Hook• Guide Support with Bolts & Nuts • Lifting Chain with Shackles (4m for TOK4-P, 5m for TOK2-65 / 65T)

TOK Application Table

Applications

• Draining sewage from factory, residence, hotel, restaurant, etc.• Pumping rainwater and springwater at a place where foreign objects are likely to run into the water• Transferring wastewater between the tanks at small-scale treatment facility

Major Components & Specifications

Single-phase

Three-phase

65

marketing
Text Box
Aussie Pumps 02 8865 3500