PROFESSIONAL TECHNICAL SERVICES UNIFORM BUILDING BY-LAW A UNIFORM BUILDING BY-LAW – DESIGN CONTROL 10.00% open space for ventilation – excluding doors (10% from the floor area calculated) special cases = Hospital 15.00% min ventilation required schools = 20.00% min ventilation required. Minimum size of air-well Where not provision of natural ventilation is provided, mechanical ventilation shall be provided into built space. For housing projects – bungalows, semi-detached houses, terraces, apartments and etc – minimum area of rooms = - Bedroom 1 - not less than 11.00m2 - Bedroom 2 - not less than 9.30m2 - Bedroom 3 - not less than 6.50m2 - minimum width of every habitable room shall be not less than 2.0m - Kitchen In residential - minimum area = 4.50m2 - minimum width = 1500mm - min. sizes of latrines, water closets and bath - squatting type - 1500 x 750 - sitting wc - 1250 x 750 - wash room - 1500 x 750 - bathroom - 2.00m2 (min width 750mm) Minimum height of Ceiling - Living/Kitchen min - 2500mm PROFESSIONAL TECHNICAL SERVICES UNIFORM BUILDING BY-LAW 1

PTS - Uniform Building by-Law 20 Feb 2012

Embed Size (px)

Citation preview

Page 1: PTS - Uniform Building by-Law 20 Feb 2012

PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW

A UNIFORM BUILDING BY-LAW – DESIGN CONTROL

10.00% open space for ventilation – excluding doors (10% from the floor area calculated)

special cases = Hospital 15.00% min ventilation required

schools = 20.00% min ventilation required.

Minimum size of air-well

Where not provision of natural ventilation is provided, mechanical ventilation shall be provided into built space.

For housing projects – bungalows, semi-detached houses, terraces, apartments and etc – minimum area of rooms =

- Bedroom 1 - not less than 11.00m2- Bedroom 2 - not less than 9.30m2- Bedroom 3 - not less than 6.50m2- minimum width of every habitable room shall be not less than 2.0m

- Kitchen In residential - minimum area = 4.50m2- minimum width = 1500mm

- min. sizes of latrines, water closets and bath

- squatting type - 1500 x 750- sitting wc - 1250 x 750

- wash room - 1500 x 750- bathroom - 2.00m2 (min width 750mm)

Minimum height of Ceiling - Living/Kitchen min - 2500mm- Bathroom min - 2000mm

Minimum height of Ceiling - sloping ceiling- Living min. - 2500mm- Kitchen ave height - 2250mm- Bath/Toilet ave height - 2000mm

(overall height shall not be less than 2m)

PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW 1

Page 2: PTS - Uniform Building by-Law 20 Feb 2012

ASSIGNMENTDATED : 20 FEBRUARY 2012

PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW

UNIFORM BUILDING BY-LAW COMPLIANCE PROJECT

PART VII – FIRE REQUIREMENTS

1. photograph A COLLECTION OF FIRE FIGHTING EQUIPMENTS; namely fire extinguisher, sprinklers, fire door, break glass, etc.

a) Describe their individual functions and also in relation to the Uniform Building By-Law.

b) Discuss from the collection of pictures taken in your selected building how these equipment are specified/placed. Are they well maintained?

c) The Uniform Building By-Law has a series of clauses specifying the construction and usage of staircases. Study and summarize all the content on staircases. Where necessary, sketches of your relevant point is advisable.

2. Under PART I – Preliminaries of the UBBL read and compile the following definitions:

Architect Approved plans Balcony Building lines Ceiling Dead load Engineer External wall Fire wall Habitable room Headroom Party wall storey

PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW 2

Page 3: PTS - Uniform Building by-Law 20 Feb 2012

PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW

3. Under PART VII – Preliminaries of the UBBL read and compile the following definitions:

Circulation space

Emergency light

Fire fighting staircase

Fire lift

Hose reel installation

Wet rising system

PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW 3