A UNIFORM BUILDING BY-LAW – DESIGN CONTROL
10.00% open space for ventilation – excluding doors (10% from the floor area calculated)
special cases = Hospital 15.00% min ventilation required
schools = 20.00% min ventilation required.
Minimum size of air-well
Where not provision of natural ventilation is provided, mechanical ventilation shall be provided into built space.
For housing projects – bungalows, semi-detached houses, terraces, apartments and etc – minimum area of rooms =
- Bedroom 1 - not less than 11.00m2- Bedroom 2 - not less than 9.30m2- Bedroom 3 - not less than 6.50m2- minimum width of every habitable room shall be not less than 2.0m
- Kitchen In residential - minimum area = 4.50m2- minimum width = 1500mm
- min. sizes of latrines, water closets and bath
- squatting type - 1500 x 750- sitting wc - 1250 x 750
- wash room - 1500 x 750- bathroom - 2.00m2 (min width 750mm)
Minimum height of Ceiling - Living/Kitchen min - 2500mm- Bathroom min - 2000mm
Minimum height of Ceiling - sloping ceiling- Living min. - 2500mm- Kitchen ave height - 2250mm- Bath/Toilet ave height - 2000mm
(overall height shall not be less than 2m)
PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW 1
ASSIGNMENTDATED : 20 FEBRUARY 2012
PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW
UNIFORM BUILDING BY-LAW COMPLIANCE PROJECT
PART VII – FIRE REQUIREMENTS
1. photograph A COLLECTION OF FIRE FIGHTING EQUIPMENTS; namely fire extinguisher, sprinklers, fire door, break glass, etc.
a) Describe their individual functions and also in relation to the Uniform Building By-Law.
b) Discuss from the collection of pictures taken in your selected building how these equipment are specified/placed. Are they well maintained?
c) The Uniform Building By-Law has a series of clauses specifying the construction and usage of staircases. Study and summarize all the content on staircases. Where necessary, sketches of your relevant point is advisable.
2. Under PART I – Preliminaries of the UBBL read and compile the following definitions:
Architect Approved plans Balcony Building lines Ceiling Dead load Engineer External wall Fire wall Habitable room Headroom Party wall storey
PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW 2
PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW
3. Under PART VII – Preliminaries of the UBBL read and compile the following definitions:
Circulation space
Emergency light
Fire fighting staircase
Fire lift
Hose reel installation
Wet rising system
PROFESSIONAL TECHNICAL SERVICESUNIFORM BUILDING BY-LAW 3