18
Form 2593-PTO REV. 7/06 MODEL: PTO 30/25 MODELS: PTO 40, 50, 55, 65, 70, 75, 90, 110 SERIES MODEL: PTO 15/12 PTO SERIES OWNERS MANUAL PTO 15/12, PTO 30/25 PTO 40-1, PTO 50-1, PTO 65-1, PTO 75-1 PTO 55-3, PTO 70-3, PTO 90-3, PTO 110-3

PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

Form 2593-PTOREV. 7/06

MODEL: PTO 30/25 MODELS: PTO 40, 50, 55,65, 70, 75, 90, 110 SERIES

MODEL: PTO 15/12

PTO SERIES OWNERS MANUAL

PTO 15/12, PTO 30/25PTO 40-1, PTO 50-1, PTO 65-1, PTO 75-1PTO 55-3, PTO 70-3, PTO 90-3, PTO 110-3

Page 2: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

2

Safety FirstWhile safety is built into everygenerator, imprudent operation,negligent maintenance or carelessnesscan contribute to present serioushazards to life and injury.

Keep a fire extinguisher nearby. Knowits proper use. Consult your local firedepartment for the correctextinguisher type. Extinguishers ratedABC by the NFPA are appropriate formost applications. Annually service the extinguishers and perform service as required.

Be sure the generator is wellventilated. Do not operate thisgenerator in an enclosed compartment.All warranties are voided if operated inan enclosed compartment.

Provide adequate ventilation for theprime mover engine on the tractor.

The output power voltage present in this equipment can cause a fatalelectric shock. This equipment must only be operated by a responsibleadult.

Do not allow anyone to operate thegenerator without proper instructions.

Guard against electric shock.

Avoid direct contact with live terminals or receptacles.

Do not operate this unit in rain or snow.

Use only 120 volt 3-wire groundedplugs and 240 volt 4-wire groundedplugs, connectors and extension cords.

This unit must be properly grounded by the operator according to theNational Electric Code and theOccupational Safety and HealthAdministration (OSHA).

Safety SymbolsThese symbols alert you to potentialpersonal injury situations. Follow theInformation to avoid possible injury or death.

This symbol indicates imminent

hazardous situations, which, if notavoided, WILL result in death or seriouspersonal injury.

This symbol indicates a

potentially hazardous situation, which, if not avoided, COULD result in death or serious personal injury.

This symbol indicates a

potentially hazardous situation, which, if not avoided, MAY result inpersonal injury.

Visual InspectionVisually inspect the unit before theinitial start. Check for loose or missingparts and any damage that may haveoccurred in shipment. You mustremove the generator from thewooden mounting base.

Ground MountingSee figures 1 and 2 for installation

on a concrete slab with mountingdimensions. Failure to mount securelywill result in damage to the generatorand possible personal injury or death.

Trailer Mounting(Optional Accessory) 3403

See figure 3 for a typical example of

a trailer. Mount the generator on atrailer if you plan to use the generatoras a portable source of power. Thetrailer should first be connected to thetractor. Next the generator should be

All pulleys, shafts, belts must beprotected with safety guards properly installed before operatingthe equipment.

When working on or around thisgenerator, do not wear neckties orloose clothing, jackets or sleeves thatmay become caught in moving parts.

Only a qualified technician shouldperform repairs on this equipment. Do not work on this equipment whilefatigued or under the influence ofalcohol or drugs. Use extreme cautionwhen working on electricalcomponents. High output voltagesfrom this equipment can cause injuryor death.

When working around engines usenoise suppression equipment and wear protective devices as necessary.Excessive noise is not only tiring, butcontinual exposure can lead to loss of hearing.

Installing and wiring a home orbuilding to a PTO generator is not ado-it-yourself project. Consult aqualified licensed electrician orcontractor. This installation mustcomply with all national and localelectrical codes. Do not connect this generator to ahome or building except through anisolation transfer switch (double poledouble throw).

When wiring an electrically drivenpump, follow all electrical and safetycodes, as well as the most recentUnited States National Electrical Code(NEC) and the Occupational Safety andHealth Act (OSHA).

ISOLATION SWITCH 6&7WIRING DIAGRAMS 8&9PARTS EXPLOSIONS 10,11,12,13,14&15ADJUSTING VOLTAGE 16OPERATING SHAFT SPEED 16GUARDS 169CONNECTIONS 17ORDERING PARTS 18WARRANTY 18

SAFETY 2TRAILER MOUNTING 2&3THREE POINT HITCH 3OPERATING 3FULL POWER CONNECTOR 3&4GROUNDING 4SHAFT INSTALLATION 4&9GEAR BOX 4MAINTENANCE 4MOUNTING 5&6

TABLE OF CONTENTS

Page 3: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

3

placed on the trailer and connectedwith the shaft to the tractor andgenerator. IMPORTANT The generatorMUST be mounted forward of thetrailer axle to prevent the trailer fromtipping backwards which can causepersonal injury or death. Once thepositioning of the generator, shaft andrelationship to the axles has beendetermined, secure the generator using4 hex bolts of at least 3/8 inch diameterwith washers and nuts. Drilling fourholes will be required. It is stronglyrecommended that the axle length beat least 41 inches before the wheelhubs. This width is recommended toprevent the torque required to turn thegenerator from causing the generatorand trailer from tipping over. Thetrailer height should enable aligningthe drive shaft in a straight or nearlystraight line between the tractor PTOand the generator PTO. Misalignmentmust be less than 10 degrees duringoperation even though the mechanicaldesign of the shaft would allow greatermisalignment. This optional trailer canbe ordered from your local dealer.

Three Point Hitch (Optional Accessory)3418

See figure 4 for a typical example

of a three point hitch. Mount the threepoint hitch to the tractor. Place thegenerator on the three point hitch.Attach the shaft to the generator andthe tractor PTO’s. Once the positioningof the generator, shaft and relationshipon the three point hitch has beendetermined, secure the generator using4 hex bolts of at least 3/8 inch diameterwith washers and nuts. The height ofthe generator should enable aligningthe drive shaft in a straight or nearlystraight line between the tractor PTOand the generator PTO. Misalignmentmust be less than 10 degrees duringoperation even though the mechanicaldesign of the shaft would allow greatermisalignment.This optional hitch can beordered from your local dealer. Drillingfour holes will be required.

Operating The GeneratorKeep the area around the

generator clear of all debris, rags etc.Do not smoke around the generator ortractor. Be certain the generator isproperly grounded. Turn the main 2pole circuit breaker on the generator tothe off position. Be certain all of thesafety guards are in place. Check thegear box inspection plate to verify thatgear oil is up to the level of theinspection point. Do not overfill the oilin the gear box. Remove any weatherprotective covers that may have beenput over the generator beforeoperating the unit. Make certain thatthe generator is properly mounted on asecure location (concrete slab, trailer orthree point hitch), no people orchildren are around the generator andplug in the electrical load into thereceptacle or full power connector.Make certain that the tractor wheelsare blocked to prevent the tractor frommoving and the parking brake isapplied. Start the tractor and at lowidling speed engage the PTO to thegenerator. Slowly bring up the speed inthe generator until the volt meterreads at least 240 volts on the PTO15/12 and PTO 30/25 (which is 60 hertz)or 60 hertz on the other PTOs (which is240 volts) and lock the tractor speed.Lower voltage, below 240 volts orbelow 60 hertz is worse than slightlyhigher voltage or slightly higherfrequency. When the tractor andgenerator are operating properly, turnthe isolation switch from the utilityposition to the off position and then tothe generator position. Next, switchthe main 2 pole circuit breaker on thegenerator to the on position and you are nowbeing powered by the PTO generator.Do not open any protective covers,control panels, etc. while the generatoris operating.

When it is time to stop operating thegenerator, you must first remove eitherthe electrical load from the generator

circuit breaker to the off position. Do not slow the generator speed downwith an electrical load on the generatoror damage to the generator and loadwill occur. Bring the tractor PTO speeddown to idle and shut the tractor PTOoff. You would then switch theisolation switch back to normal utility power.

Isolation Switch andIsolation CircuitsSee figure 5 for the proper installationof a customer supplied isolation switch.

Installation of an isolation switch

must be done by a licensed electrician.Back feeding of electrical power from agenerator without a proper isolationswitch installed can kill servicepersonnel working on power linesand/or damage equipment when theutility returns normal power. See figure5 for a sample wiring of an isolationswitch. Do not operate this generatorin parallel with another generator. Theisolation switch has three positions,utility position, off and generatorposition. The National Electrical Codeand local codes require an isolationswitch be installed between a standbygenerator (such as a PTO generator) and the utility lines. See figures 6 and 7for Isolation Circuits.

Full Power ConnectorInstallation

See figures 15 and 17 . The connector

has been assembled at the factory. Onlya licensed electrician should install thewire cables to the connector. Failure toproperly connect the wires will result indamage to the equipment and/orpersonal injury. Consult a wireampacity chart for the proper wiregauge size for a given generator. Youmust use stranded copper weldingcable with a 600 volt rating and aminimum of 3AWG hypalon insulation.The wires must be stripped about 0.75inch from the end of the cable. Insertthe end of the wire into the open

Page 4: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

or turn the generator main 2 polecontact. Use a heavy crimping tool tosecure the wire into the contact. Insertthe four contacts into the full powerconnector making certain that they aresecurely in place.

GroundingProper grounding will prevent an

electric shock in the event loss ofinternal ground or loss of a ground inthe load. The National Electric Coderequires at least a number 12AWGstranded copper wire to the groundinglug on the generator. Connect the lugto a copper or brass grounding roddriven into the earth. DO NOT attachground connections to gas or waterpipes.

Wiring DiagramsSee figure 8 for PTO 15/12

See figure 9 for PTO 30/25

See figures 10 and 10A for all otherPTOs

Typical InstallationSee figures 5, 6 and 7 for all models.

Shaft InstallationSee figure 11 for all models. It is

strongly recommended to keep theangle of the shaft within 10 degreesfrom the tractor PTO and generatorgear box. Do not operate over 540 RPM.A three point hitch requires a shortshaft and a two-wheel trailer andground mounting requires a long shaft.These optional shafts can be orderedfrom your local dealer. Keep guards inplace at all times.

Gear BoxThe gear box is a self contained

helical gear unit. It has a glassinspection plate. Be sure to check

before using the generator that thegear oil is at the fill line. Use SAE 90gear oil. DO NOT overfill the oil orleaks may occur. The fill location is atthe top of the gear box, inspectionplate is on the side of the gear box and the drain plug is located on thebottom of the gear box. This gear boxis not to be serviced in the field. Allgear boxes have been filled with gearoil at the factory. The cone guards mustbe in place at all times.

Parts ExplosionsSee figure 12 and13 for PTO 15/12

See figure 14 and 15 for PTO 30/25

See figure 16 and 17 for PTO 40-1,PTO 50-1, PTO 65-1, PTO 75-1,

PTO 55-3, PTO 70-3, PTO 90-3

MaintenanceIt is recommended to lubricate the shaft with a lithium base grease. In thewinter with freezing conditions, thePTO shaft should be greased with abrush to avoid sticking and freezing.Before using the generator, be sure toclean the generator and remove dirtetc. Barns may contain a lot ofmoisture, dirt and ammonia-type gasesthat can lead to corrosion of copperwire. Store this unit in a clean area. Letthe generator cool down completely before placing any protective cover over the generator.

To maintain your generator

under warranty, you must use originalfactory parts. Use of non factoryoriginal parts will void the warrantyand the manufacturer does not acceptany claims for property damage, injury,death or any other damages caused bythe non factory authorized parts.

The gear box oil should be changedevery 250 hours of operation, the shaftshould be lubricated with each use, andthe generator should be tested at leastevery 3 months.

4

Page 5: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

5

Figure 1 – Concrete Mounting

Figure 3 – Two Wheel Trailer 3403 (Optional), Weight 175lbs., Tires P175/80R13 M+S(14” Hub)

Figure 2 – Concrete Mounting Dimensions

MMOODDEELL AA BB CC DD EE

PTO 15/12 18.0 (457) 9.92 (252) 13.625 (346) --- 21.0 (533)

PTO 30/25 22.0 (559) 13.8125 (351) 19.0 (483) --- 27.0 (686)

PTO 40-1 22.0 (559) 13.38 (340) 12.2 (310) 16.9 (429) 27.0 (686)

PTO 50-1 22.0 (559) 13.38 (340) 12.2 (310) 16.9 (429) 27.0 (686)

PTO 65-1 22.0 (559) 13.38 (340) 12.2 (310) 16.9 (429) 27.0 (686)

PTO 55-3 22.0 (559) 13.38 (340) 12.2 (310) 16.9 (429) 27.0 (686)

PTO 70-3 22.0 (559) 13.38 (340) 12.2 (310) 16.9 (429) 27.0 (686)

PTO 75-1 26.0 (660) 15.9 (406) --- 13.7 (347) 24.0 (610)

PTO 90-3 26.0 (660) 15.9 (406) --- 13.7 (347) 24.0 (610)

PTO 100-3 26.0 (660) 15.9 (406) --- 13.7 (347) 24.0 (610)

54

2879.5

49

TRACTOR

HERE

Page 6: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

6

Figure 5 – Isolation Switch

Figure 4 – Three Point Hitch 3418 (Optional), Weights 92lbs.

33.5

24.5 38.5

Page 7: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

7

VARIOUS LOADSON GENERATOR

UTILITY LINESL N L

ELECTRIC METER

MAIN CIRCUIT BREAKER PANEL

VARIOUS LOADS(NOT ON EMERGENCY GENERATOR)

POWER RETURN LIGHT

ISOLATION SWITCH(SHOWN IN NORMAL POWER FEED)

VARIOUS LOADS(NOT ON EMERGENCY GENERATOR)

L

N

L

GENERATOR

Figure 6 – Selected Isolation

Figure 7 – Total Isolation

UTILITY LINESL N L

ELECTRIC METER

CIRCUIT BREAKER PANEL

VARIOUS LOADS

POWER RETURN LIGHT

ISOLATION SWITCH(SHOWN IN NORMAL POWER FEED)

L

N

L

GENERATOR

VARIOUS LOADS

Page 8: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

8

Figure 8 – Wiring Diagram for Model PTO 15/12

Figure 9 – Wiring Diagram for Model PTO 30/25

Page 9: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

9

Figure 10 – Wiring Diagram for Single Phase Models PTO 40-1, PTO 50-1, PTO 65-1(PTO 75-1 not shown and does not have a circuit breaker)

Figure 11 – Shafts 3397 (long) 57”-67” and 3421 (short) 37”-50”(Length Dimensions are end of hub to end of hub. 1 3/8” 6 spline both hubs)

Figure 10A – Wiring Diagram for Three Phase 240V, Delta Models PTO 55-3, PTO 70-3,(PTO 90-3 and PTO 110-3 not shown do not have a circuit breaker)

Page 10: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

Figure 12 – Parts Explosion for PTO 15/12

10

Repair Parts List for Model PTO 15/12

Item Part No. Description Quantity

1 3344 Rotor Screw Cover 12 3342 End Cover 1 3 3282 Grommet 24 3346 Stator 15 2615 Ball Bearing 52 mm 16 3330 Fan Guard 27 3328 Fan Bracket 18 3332 Fan 19 3349 Fixing Ring 1

10 3336 Rotor 1

Item Part No. Description Quantity

11 3190 Diode 212 2603 Varister 213 3341 Rotor Screw 114 1135 Capacitor 35 mf 115 3670 Bushing 116 3281 Top Cover 117 3184 Terminal Strip 118 3382 Gear Box Transmission Car 3P 118 3383 Safety Cone 119 3168-B Base Plate 1

Page 11: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

11

23

26

25

24

27

28

22

21

20

Figure 13 – Parts Explosion for PTO 15/12

Item Part No. Description Quantity

20 3506 Receptacle 50 A, 240 V 121 1112 Circuit Breaker 30 A 222 1101 Receptacle T/L 30 A,240 V 123 3378 Control Box Back 124 3015 Circuit Breaker 50 A, 2 Pole 125 3377 Front Panel 126 1069 Circuit Breaker 20 A 127 1011 Receptacle Duplex 20 A, 120 V 128 1024 Ground Lug 129 2024 Volt Meter 1

29

Page 12: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

12

Figure 14 – Parts Explosion for PTO 30/25

Item Part No. Description Quantity

1 3359 Bracket PTO Side 12 3361 Ball Bearing 90 mm 13 3362 Fan 14 3363 Diode 15 3356 Stator 16 3364 Ball Bearing 80 mm 17 3365 Spring Washer 18 3368 Bracket (Control Box Side) 19 3355 Cover 1

10 3184 Terminal Strip 1

Item Part No. Description Quantity

11 1134 Capacitor 30 mf 211 3217 Capacitor 40 mf 112 3355-T Top Cover 113 3318-LH Lifting Hook 114 3357 Rotor 115 3358 Fan Guard 216 3383 Safety Cone 116 3381 Gear Box M5 117 3360 Channel 2

Page 13: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

13

Item Part No. Description Quantity

18 2024 Volt Meter 119 3369 Circuit Breaker 100 A, 2 Pole 120 1101 Receptacle T/L 30 A, 240 V 121 1112 Circuit Breaker 30 A 222 1069 Circuit Breaker 20 A 123 1011 Receptacle Duplex 20 A, 120 V 124 1024 Ground Lug 125 3375-F Front Panel 126 3379 Connector (Assembly of 2) 127 3379 Connector Male loose (2) 128 3380 Connector Handle 1

Figure 15 – Parts Explosion for PTO 30/25

24

23

20

18

21 22

25

26

19

26 27

28

Page 14: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

14

Figure 16 – Parts Explosion for PTO 40-1, PTO 50-1, PTO 65-1, PTO 75-1, PTO 55-3, PTO 70-3, PTO 90-3, PTO 110-3

Item Part No. Description Quantity

1 3655 Fan 12 3654 Rotor 13 3653 Exciter Armature 14 3652 Diode Bridge with Diodes 15 3671 Ball Bearing 6312.2RS 15A 3672 Ball Bearing 6309.2RS 16 3649 Stator 17 3651 Exciter Stator 18 3647 Bracket (Non PTO Side) 19 3673 End Cover 1

Item Part No. Description Quantity

10 3656 Automatic Voltage Regulator 111 3660 Mounting Plate Control Box 112 3648 Terminal Strip 113 3659 Side Panels 214 3646 Top Cover 115 3657 Stator Thru Bolts 416 3650 Fan Bracket 117 3658 Fan Guard 118 3662 Gear Box transmission M7, M9 118 3383 Safety Cone 1

Page 15: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

15

27

1924

25

23222120

26

Item Part No. Description Quantity

19 3661 Connector Cover 120 3506 Receptacle 50 A, 240 V 121 2883 Circuit Breaker 50 A, 1 pole 222 1069 Circuit Breaker 20 A 123 3673 Front Cover 124 1011 Receptacle Duplex 20 A, 120 V 125 1024 Ground Lug 126* 3512 Circuit Breaker 175 A, 2 Pole 127 3479 Frequency (Hertz) Meter 128** 3379 Connector Male Loose (2) 129** 3380 Connector Handle 1

Item Part No. Description Quantity

* 3569 PTO 40-1 125A, 2 Pole 13570 PTO 50-1 175A, 2 Pole 13571 PTO 65-1 225A, 2 Pole 13572 PTO 55-3 150A, 3 Pole 1

** 3379 and 3380 Used on PTO 40-1,PTO 50-1 and PTO 55-3 1

** 350A Used on PTO 65-1,PTO 75-1,PTO 70-3, PTO 90-3 and PTO 110-3 1

Figure 17 – Parts Explosion for PTO 40-1, PTO 50-1, PTO 65-1, PTO 75-1, PTO 55-3, PTO 70-3, PTO 90-3, PTO 110-3

29

28

* Model PTO 50-1 shown(Models PTO 75-1, PTO 90-3 and PTO 110-3, do not come with a main line circuit breaker. customer supplied)

SINGLE PHASE

THREE PHASE

LINE

LINE

LINE

NEUTRAL

LINE

LINE

NEUTRAL

GROUND

Page 16: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

16

Adjusting Voltage for PTO’sAll PTO’s with 12 wireunits feature an

automatic voltage regulator that willmaintain +/- 1 ½% voltage regulation.The voltage regulator is preset at thefactory for the required voltage. If achange in voltage is required, thefrequency meter MUST be connected toone line (hot) wire and to the neutralconnection for the meter to function.On a three phase 240 volt series deltaconnection, there is no neutral. Forneutral conncection you must use thecenter tap(CT) adjacent to the lineconnection you choose. With thefrequency meter operating at 60 hertz(50 hertz for 50 hertz operation and thejumper installed) you can increase ordecrease the voltage by simply adjustingthe Phillips screw marked VOLTS on theautomatic voltage regulator. See connections/reconnections page

The generator mustbe operating at the

proper speed (RPM) before and whileadjusting the voltage regulator. Turn theVOLTS adjusting screw very slowly stopand wait 2 or 3 seconds and read thevoltage from one of the lines andneutral connection (note that on thethree phase 240 volt series deltaconnection there is no neutral so youmust go to the center tap as a neutral.Adjust the voltage up or down byturning the VOLTS clock wise or counterclock wise. Once the voltage is adjusted,do not adjust any of the other Phillipsscrews on the automatic voltageregulator. Refer to the re connectionchart if you are changing voltages. Nearthe automatic voltage regulator are themain power terminals of the generator.If you make contact with the mainterminals, serious injury and death willoccur. These adjustments MUST be doneby a licensed electrician or technicianfamiliar with high voltage equipment.This is NOT a do it yourself activity.

From the automatic voltage regulatorterminal 4 a green wire always goes tostator lead wire 3. From the automaticvoltage regulator terminal 5 a blackwire always goes to stator lead wire 4.This applies to single and three phaseunits both 50 and 60 hertz and anyvoltage combination. On 60 hertzversions, single and three phase and anyvoltage combination,

there is a small brass jumper connectedon the automatic voltage regulatorbetween terminal 5 and terminal 6. For50 hertz operation, this jumper isremoved.

Adjacent to the automatic voltageregulator is the radio suppressor onsome models. The lead wires from theradio suppressor are always red andmust go to the stator leads wires 5, 7, 9and 12 on any version in single or threephase., 50 or 60 hertz and any voltagecombination. Some leads may be onthe same terminals as other dependingon the various phase and voltagecombinations.

Changing voltage will change theamperage output of the generator. Thecircuit breaker should be changedaccordingly.

OPERATING GENERATORSHAFT SPEED

For 60 hertzoperation the

generator shaft speed of 1800 RPMmust be continuously maintained. Theoperating speed range is 1700 RPM to1900 RPM for 60 hertz. Shaft speed ofthe gear box connected to thegenerator is either 540 RPM or 1000RPM depending on the model. Slightlylower gear box speed(about 520 RPMfor the 540 RPM on/or 970 RPM for the1000 RPM unit is acceptable, thefrequency meter at 60 hertz is how todetermine proper speed. These are NOTvariable speed generators.

GUARD FOR PULLEYS, BELTSAND COUPLINGS

All rotating equipment MUST

be equipped with guards to preventcontact with rotating shafts, pulleys,belts and couplings. The customer isresponsible for installing theappropriate guards. Serious personalinjury or death could result withoutproper guards in place while thegenerator is in operation.

Page 17: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

17

PTO Series Connections/RE Connections 60 Hertz 12 Wire Generators

SINGLE PHASE 120/240 VOLTS PARALLEL ZIG ZAG

SINGLE PHASE 120/240 VOLTS DOUBLE DELTA

DO NOT USE OTHER CONNECTION TERMINALS

CT = CENTER TAP

L3 = LINE N = NEUTRAL

L2 = LINE L1 = LINE

THREE PHASE 120/208 VOLTS

FOR 50 HERTZ CONNECTIONS, CONSULT THE FACTORY.

PARALLEL STAR THREE PHASE 240 VOLTS

SERIES DELTA (NO NEUTRAL)CT CENTER TAP

THREE PHASE 277/460/480 VOLTSSERIES STAR

VOLTAGE REGULATORS

Page 18: PTO SERIES OWNERS MANUAL - Electric Generators Direct · idling speed engage the PTO to the generator. Slowly bring up the speed in the generator until the volt meter reads at least

ORDERING PARTS Instructions For Ordering Repair Parts

For parts or service, contact either the factory or the dealer or distributor from whom you purchased this equipment for the name of the nearest authorized service station.

1. To avoid errors or delay in filling your parts order, please furnish all information requested and always refer to the nameplate on your unit by giving the model and serial number.

2. Do not order by reference number or group number. Always use part number and description.

3. Give the part number, description and quantity needed for each item.

4. State definite shipping instructions. Any claim for loss or damage to your unit in transit should be filed promptly against the transportation company making the delivery. Shipments are complete unless the packing list indicated items are back ordered.

5. FOR SERVICE OR PARTS CONTACT THE FACTORY AT:

Wanco/Voltmaster 5870 Tennyson Street, Arvada, Colorado 80003. Phone 800-730-3927 Fax 303-427-5725

FIVE/ONE YEAR LIMITED WARRANTY- PTO SERIES Five year limited warranty on parts and a 1year limited warranty on labor.

This warranty extends to the original purchaser only. The generator sold is warranted to the original purchaser for a period of five (5) years for parts only and one (1) year for labor only from the original purchase date. The manufacturer warrants the generator sold to be free from defects in material and workmanship if properly installed, serviced and operated within nameplate rating under normal conditions according to the manufacturer's instructions.

Disclaimers

This warranty does not apply to any items which must be repaired or replaced due to normal wear, which have been subject to misuse, negligence, accident or which have been repaired, altered by others outside of the manufacturer's factory unless authorized in writing by the manufacturer. Under no circumstances will the manufacturer be liable for any or consequential damage or expense of any kind, including loss of profits nor the fitness of the product for any specific application or particular purpose. Any implied warranties are limited in duration to the above one (1) year period. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.

Performance

The manufacturer's obligation under this warranty is limited to correcting without further charge at its factory or authorized service station any part or parts which shall be returned transportation charges prepaid, and which upon examination shall disclose to the manufacturer's satisfaction to have been originally defective. Other than transportation charges, no charge will be made for such repair adjustment and /or replacement. This remedy is expressly in lieu of all other remedies, and is the purchaser's sole and exclusive remedy hereunder.

18