MC-DPTAC www.amana-ptac.com 9/12Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Supersedes 6/12
Packaged Terminal air condiTioners and HeaT PumPs
wiTH our digismarT® conTrol Board & ems
PTac sPecificaTions and accessories caTalog
Assembled in the USA for 30 years: Units are 100% run-tested and triple-tested for leakage.
• First-Year Warranty: Parts & Labor on entire unit• Second through Fifth Year: Parts & Labor on certain sealed
system components
• Second through Fifth Year: on certain functional parts only* Complete warranty details available from your local dealer or
at www.amana-ptac.com.
2 www.amana-ptac.com MC-DPTAC
• EnergyEfficiencies:WithEERsupto11.7andCOPsupto3.4,ourunit’shighefficienciesmayqualifyyouformanyoftherebatesofferedbyelectricalpowercompanies.
• QuietOperation:OurPTAChasbeenredesignedtobethequietestPTACwe’veeverbuilt.Theunit’sstate-of-the-artdesignandconstructionprovideaquietenvironment,allowinggueststoenjoypeaceful,sleep-fillednights.• Twofanmotors(indoor/outdoor)• Indoortangentialfanforquietoperation• STCof28
• AssembledintheUSAfor30years:assembledatourplantinFayetteville,TN,usingGoodmanresourcesincludingengineering,production,andtesting.
• IncreasedDehumidificationCapacity:Maintainlowerhumiditylevelsinroomswhilecoolingthemwithouttheneedforexpensiveadd-ons.Asaresult,guestsfeelmorecomfortableathighertemperatures,thusreducingcoolingcosts.
• Seven-ButtonTouchPad:Providescompletecontroltoguestsforin-roomcomfortwhilemaintainingenergyefficiency.• Five-YearLimitedWarranty:Enjoyoneofthemostcomprehensivewarrantiesintheindustry:FirstYear:parts&labor;Secondthroughfifthyears:parts&laboroncertainsealedsystemcomponents;secondthroughfifthyears:oncertainfunctionalpartsonly.Forcompletewarrantydetails,visitwww.amana-ptac.com.
• 100%RunTested:Allunitsare100%runtestedatourplantinFayetteville,TN,includingleakchecksduringmanufacturingandagainpriortoshipmentatthewarehouse.
• 7⅝”UnitFrontDepth:Enhancevaluableroomspacewithourslimunitfront,whichhasasleek7⅝”depth,oneoftheshallow-estsilhouettesintheindustrytoday.Inaddition,toinhibitguest-tampering,thefrontcanbesecuredtothechassiswithahiddenscrew.
• RemovableCondenserShroud:Allowseasyaccesstoenableregularcleaningofcoils,whichisessentialtomaintainunitefficiencyandprotectthecompressorforlongunitlife.
• EasyPull-OutFilters:Ourfiltersarewashableandeasytomaintain.• FilterDryerforSealedSystemRefrigerant:Standardinallunitstoprotectthecompressorandlengthenthelifeoftheunitbyremov-ingmoistureandpreventingacidformation.
Removable/Cleanable ShRoud foR eaSy Cleaning
filteR dRyeR
eaSy Pull-uP filteRS
Control Board
sTandard feaTures
MC-DPTAC www.amana-ptac.com 3
sTandard feaTures (conT.)• CondensateDispersionSystem:Ourcondensatedispersionsystemremovescondensatefromindoorcoolingoperationbythrowingwaterdirectlyontotheoutdoorcoilforrapidevaporationandincreasedcoolingefficiencies.Theslingerringonthenew,enhancedfandrawswaterupandintothefanblades.Thiswateristhenatomizedandevaporatedintotheatmospherethroughthecondenser.Increasedsurfaceareafromthecoilallowsmorewatertobeevaporatedonthesidesofthecoilsandhelpstominimizecondensaterun-off.
• FrontDeskControl:EachunitcomesequippedwiththeDigiSmart™controlandenergymanagementsoftware.WithDigi-Smart™usingtheoptionalRFAntennae,allunitscanbewirelesslyconnectedtoacentralhubforenhancedenergysavingsanddiagnostics.AmanabrandPTACsalsohavealow-voltageinterfacecapabilitywithafield-suppliedfront-deskON/OFFswitch.(SeePage4.)
• RoomFreezeProtection:Whentheunitsensestemperaturesof40°Forbelow,theunitactivatesthefanmotorandeithertheelectricresistanceheaterorthehydronicheater.
• Easy-to-useControls:Nocomplexcontrolstoconfuseyourguestsandcreatephonecallsforyourmanager.Controlsareeasytoread,understand,andactivate.Ournew7-buttoncontrolpanelprovidesguestswithcompletecontroloftheunitfortheirin-roomcomfortwhilemaintainingoverallenergyefficiency.
• EasytoServicewithOn-BoardLEDDiagnostics:Themaincomponentsareeasilyservicedandthereisnoguessingtodeterminetheproblemwithoureasy-to-readdiagnostics.
• StonewoodRoomFront:OurStonewoodroomfrontstrikesthebalancebetweenattractivestylingandpracticaldesign.Distinc-tivecontoursandamodernappearanceenhancethecharacterofeventhemostluxuriousroom,whilethesleek7⅝”depthmaximizesusablespaceforyourguests.
• RemoteThermostatControl:WhentheDigiSmart™wirelessremotethermostat(DS01E,soldseparately)issetup,boththeremotethermostatandunitcontrolpanelcontinuetocontroltheunit,providingflexibilityandhome-likesystemcontrol.Installa-tionrequiresnomorethanpressingtwobuttons.Noneedtorunwiresormakeelectricalconnections.
• RemoteTemperatureSensing:Guestsenjoyultimatecomfortwithconsistentclimatecontrol.Whenthefield-installedthermistor(RTS03)isused,theunit-mountedthermostatisoverriddentoallowmoreaccurate,internalwall-sensingofroomambienttemperature.
• ExtendedHeatPumpHeating:Heatpumpmodelswilloperateintheheatingmodedowntoaslowas24°Foutdoorambienttem-perature.
• ZeroFloorClearance:Theunitcanbeinstalledflushtoafinishedfloor,ifdesired.(Someaccessoriesdonothavezeroclearance).• 30-SecondFan-OffDelay:Thefancontinuestorun30secondsafterthecompressorhasstoppedineithercoolingorheatpumpmodeandafterelectricheathasbeenturnedoff.Thisimprovesefficiencybydispersingtheconditionedaironthecoilsintotheroom.
• CompressorLock-In:Thisfeaturehelpsprolongthelifeofthecompressorbypreventingshort-cycling.WhenthecompressorisswitchedfromOfftoOnbecauseroomtemperaturehasrisenorfallenbelowthespecifiedlimit,itwillremainonforatleast4minutes.Ifthetemperatureset-pointischangedduringthis4minutes,thelock-infeatureisoverridden.
• AutomaticEmergencyHeat:Nomore“myunitisnotheating”complaintsduringthemiddleofthenight.Heatpumpunitswillautomaticallyswitchovertoelectricresistanceheatiftheheatpumpcompressorsystemfailsoriftheheatingloadisgreaterthantheunitcapacity.
• ConstantFanMode:Takeadvantageofeachunit’sdualoptions—selectcontinuousfanoperationorcyclethefanONandOFFwiththethermostat.Ournew7-buttondesignallowsgueststoselectfanperformancewhileallowingtheownertohavetheunitreverttothedesiredprogramofcontinuousfanorcyclewithconditioning.
• HiddenVentilationControl:Theventilationcontrolleverishiddenfromtheoccupant'sviewtoallowyoutomanageventilationrequirements.
• High-PressureSwitch:Protectstheunitfromhighpressureanddamagetotheunit,helpingtoensurelongunitlife.
4 www.amana-ptac.com MC-DPTAC
brings together our best PTAC everwith our best EnergyManagement Software andnow integrationwithPropertyManagementandFrontDeskManagementSoftware.ReducePTACenergy consumptionby35%ORMORE* throughthepowerofthein-unitEnergyManagementSystem,programmabletemperatureset-backandlimitscombined.ReducePTACmaintenancecostthroughourautomatedmaintenancenotificationsystem.Improvedmaintenancesustainsenergyefficiency(EER)andprolongsPTAClife,keepingequipmentrunningatitsdesignedefficiencylevelandroomguestsmorecomfortable.
THe amana Brand digismarT soluTion
in-room: “self-insTallaBle” wireless PeriPHerals
TheDigiSmartOccupancySensorcompletesthein-roomequipment.Thisinfraredsensorcandetermineiftheroomisoccupiedorempty,andwhenemptysignalsthePTACtoadjustthetemperaturetosaveenergybasedonprogrammablesetbacks.
TheDigiSmartWirelessRemoteThermostatcanmountonthewallanywhereintheguestroom.BatterypoweredandwithitsownwirelessabilitytocommunicatewiththePTACtomaintainroomtemperature.Bestofall,nowirestorun.ThePTACandThermostatconnectatthepressofabuttonandarepermanentlylinked.ThethermostatandPTACworkin-synctodisplayaccuratetemperature.
TheDigiSmartWirelessAntenna installs inside thePTACwitha snap-inconnector. Installing theantennaallows thePTAC tocommunicatewirelesslywithotherdevicesintheroomandtotheDigiSmartnetwork.>45,000+roomshavehadwirelessinstallationssince2005>Totalwirelessdevicesdeployedtodate:120,000+
TheAmanabrandDigiSmartPTACwithantenna,combinedwiththeself-installable,wirelessThermostatandOccupancySensorgivethepropertyownercompletecontrolovertheequipmentsettingsandcanreducePTACenergyusageby35%ORMORE.*
siTe-level —cenTral wireless conTroller
>Site-widePTACConfiguration>Site-widePTACDiagnostics>FrontDeskSystemInterface>EmailReporting>InternetAccessibleWebUserInterfaceEnterprise
*ThesesavingsrepresentestimatedsavingsovertimeascomparedtothesamePTACmodelwithouttheDigiSmartEMSSysteminstalledandweregeneratedusinggeneralassumptionsincludingenergyloads,localweatheraveragesanduseofoccupancycontrols.Actualsavingswillvaryaccordingtoactualusehabits,roomsquarefootage,andhowtheunitisinstalled.
MC-DPTAC www.amana-ptac.com 5
enTerPrise — mulTiPle wireless conTrollers
CentRal monitoRing and
ContRol of multiPle PRoPeRtieS
>DataWarehousing>SavingsAnalysis>EmailReporting>VirtualMetering>LoadShedding
weB-Based, real-Time moniToringamana® Brand digismarT™ conTroller:AllofthePTACsinthebuildingcanbemanagedthroughasingleinterfaceonaPC.
FEATURES INCLUDE: Full unit details for every PTAC, visible from the front desk or home office, automatic emails for PTACmaintenance,abilitytochangeallsettingsontheunit,andenhanceddiagnostics.Monitorupto170PTACs,WIRELESSLY,withonecontroller.Additionalcontrollerscanexpandthenetworkforadditionalrooms/properties.
>SystemVerification>GlobalSetbacks>EMSConfiguration>SiteStatistics>BatteryNotices>EmailReporting>UnitHealth>UnitCodeAlerts
Temp Limiting – Each PTACcanbe configuredwith a heat-ing and cooling temperatureset-pointlimit.Setbacks–Oncearoomisdeclaredunoccupiedbytheoccupancysensor,thePTACprogressesthroughthreedifferenttemperaturesetbacks,configuredasthreedegreeandtimepairs(Anexampleconfigurationislistedbelow).1st:2°,30mins–Setbackthetemp2degreesafter30minutes2nd:4°,1hr–Setbackthetemp2moredegreesafter30moreminutes3rd:8°,3hrs–Setbackthetemp4moredegreesafter2morehoursUnrentedSet-Points–Byintegratingwithyourproperty'sFrontDeskSystem,thePTACswilladjusttospecificset-pointswhennolongeridentifiedasrentedinthesystem.
6 www.amana-ptac.com MC-DPTAC
nomenclaTure
Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor RevisionsPTH Standard Heat Pump PTHPDRY Dehumid Cooler PTAC Features Code
A Standard ModelCooling Capacity C Corrosion Protec>on (Seacoast)07 7000BTU/h 60 Hz D Power Door09 9000 BTU/h 60 Hz F Fuse Holder (230/208 Only)12 12000 BTU/h 50 or 60 Hz H Hydronic Heat-‐Capable15 14000 BTU/h 60 Hz P Condensate Pump (PTH Only)
Q Quiet STC 31 ChassisRated Voltage R RF Antenna2 115V, 60 Hz, 1 Ph V Power Vent3 230/208V, 60 Hz, 1 Ph X placeholder4 265V, 60 Hz, 1 Ph W Hard-‐Wired (PTQC)5 240/220V, 50 Hz, 1 Ph
Use up to 4 as needed in alphabe>cal orderDesign Series Examples:E R-‐410A PTC123E50AXXX PTC073E35CRXXG R-‐410A PTC123E50CXXX PTC073E25CQRWHeater Size00 No Electric Heat 3.5 kW (230/208V)15 1.5 kW 3.7 kW (265V)25 2.5 kW 5.0 kW50
35
AA
1,2,3 4 5 6 7,8,9 10,11,12,13 14
PTC 07 3 E 35 AXXX
Allunitscomewithfactory-installedpowercords.Allunitslessthan250voltscomewithLCDIdevice.
PowerReceptacleConfiguration
NEMA6-30R; 250V receptacle,used on 230/208V units
GNEMA7-30R; 277V receptacle,used on 265V units
G NEMA6-15R; 250V receptacle,used on 230/208V units
G NEMA6-20R; 250V receptacle,used on 230/208V units
G
WNEMA7-20R; 277V receptacle,used on 265V units
G
277VRatingPowerCordPlugsNEMA7Configuration
G
W
20 amp
G
W
30 amp
250VRatingPowerCordPlugswithLCDIDeviceNEMA6Configuration
PowerCordPlugs
15 amp 20 amp 30 amp
Power cord configuraTion
MC-DPTAC www.amana-ptac.com 7
ProducT sPecificaTions: PTc models — cooling/elecTric HeaT (conT.)230/208 Volts
Model ⁶, ⁸, ⁹PTC
073G***XXXPTC
093G***XXXPTC
123G***XXXPTC
153G***XXX
Voltage ³ 230 / 208 230 / 208 230 / 208 230 / 208
Capacity (BTU/h) 7,700 / 7,700 9,000 / 9,000 11,700 / 11,500 15,000 / 14,700
Amps ¹⁰ 3.5 / 3.5 4.1 / 4.1 5.6 / 5.6 7.0 / 7.0
Watts ¹⁰ 670/660 805/785 1135/1105 1500/1470EER 11.5/11.7 11.2/11.5 10.3/10.4 10.0/10.0
Unit without Electric Heater
Min. Circuit Amps ², ⁴, ¹⁰ 4.2 4.9 6.8 8.5
CFM (Cool/Wet Coil)High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidification (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 98 102 102 113Ship Weight (lbs.) 113 117 119 130
265/277 Volts
Model 1, 6, 8 PTC074G***XXX
PTC094G***XXX
PTC124G***XXX
PTC154G***XXX
Voltage ¹, ³ 265 265 265 265
Capacity (BTU/h) 7,700 9,000 12,000 14,800
Amps ¹⁰ 3.0 3.6 4.8 6.0
Watts ¹⁰ 670 795 1,165 1,480EER 11.5 11.3 10.3 10.0
Unit without Electric Heater
Min. Circuit Amps ², ⁴, ¹⁰ 3.6 4.4 5.9 7.4
CFM (Cool/Wet Coil)High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidification (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 98 102 102 113Ship Weight (lbs.) 113 117 119 130
* Actual vent CFM performance will vary due to application and installation conditions.Notes¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit PTPWHWK4 and disconnect switch PSHW04A.² Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply. ³ Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts. ⁴ Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses (included and
factory-installed on all Amana® brand 265-volt chassis). See heater performance ⁵ Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient.⁶ Specify two-digit heater kW size to complete model number.⁷ R-410A refrigerant used in all systems.⁸ All units meet or exceed ASHRAE 90.1 standards.⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.¹⁰ Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
8 www.amana-ptac.com MC-DPTAC
230208 voltS
Model ⁶, ⁸, ⁹PTH
073E**AXXXPTH
093E**AXXXPTH
123E**AXXXPTH
153E**AXXX
Voltage ³ 230 / 208 230 / 208 230 / 208 230 / 208
Capacity (BTU/h) 7,600 / 7,500 9,000 / 8,900 11,500 / 11,100 14,000 / 13,900
Amps ¹⁰ 3.5 / 3.5 4.1 / 4.1 5.6 / 5.6 7.0 / 7.0
Watts ¹⁰ 650 / 620 770 / 765 1095 / 1065 1460 / 1465
EER 11.3 / 11.4 11.1 / 11.1 10.2 / 10.1 9.6 / 9.5
Unit without Electric Heater
Min. Circuit Amps ², ⁴, ¹⁰ 4.2 5.0 6.8 8.5
CFM (Cool/Wet Coil)High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidification (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 108 112 115 126
Ship Weight (lbs.) 123 127 132 143
265,277 voltS
Model ¹, ⁶, ⁸PTH
074E**AXXXPTH
094E**AXXXPTH
124E**AXXXPTH
154E**AXXX
Voltage ¹, ³ 265 265 265 265
Capacity (BTU/h) 7,500 9,000 11,500 14,000
Amps ¹⁰ 3.0 3.6 4.8 6.0
Watts ¹⁰ 635 780 1115 1430
EER 11.6 11.1 10.0 9.7
Unit without Electric Heater
Min. Circuit Amps ², ⁴, ¹⁰ 3.6 4.4 5.9 7.3
CFM (Cool/Wet Coil)High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidification (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 108 112 115 125
Ship Weight (lbs.) 123 127 132 142
* Approximately 95 CFM with optional power vent kit. Actual vent CFM performance will vary due to application and installation conditions. See Notes on previous page
ProducT sPecificaTions: PTH models — cooling/HeaT PumP/elecTric HeaT
MC-DPTAC www.amana-ptac.com 9
230/208 voltS
Heating CapacityPTH
073E**AXXXPTH
093E**AXXXPTH
123E**AXXXPTH
153E**AXXX
Voltage ³ 230 / 208 230 / 208 230 / 208 230 / 208
BTU/h ⁵ 6,800 / 6,800 8,300 / 8,100 10,900 / 10,500 13,500 / 13,300
Amps ¹⁰ 3.5 / 3.5 4.1 / 4.1 5.6 / 5.6 7.0 / 7.0
Watts ¹⁰ 605 / 605 735 / 720 1040 /1020 1365 / 1345
COP5 3.3 / 3.3 3.3 / 3.3 3.1 / 3.1 2.9 / 2.9
CFM (Dry) 310 310 310 360
265/277 voltS
Heating CapacityPTH
074E**AXXXPTH
094E**AXXXPTH
124E**AXXXPTH
154E**AXXX
Voltage ³ 265 265 265 265
BTU/h ⁵ 6,800 8,200 11,000 13,500
Amps ¹⁰ 3.0 3.6 4.8 6.0
Watts ¹⁰ 585 730 1040 1365
COP ⁵ 3.4 3.3 3.1 2.9
CFM (Dry) 310 310 310 360
COP=CoefficiencyofPerformance;perARItestprocedures,unitsareratedforcapacitiesandefficiencies.SeeNotesonPage7.
ProducT sPecificaTions: PTH models — reverse-cycle HeaTing Performance
ProducT sPecificaTions: PTc / PTH models — elecTric HeaT Performance(PrimaryHeatingforPTCModels;AuxiliaryHeatingforPTHModels;SeebelowforPowerCordConfiguration)
VoltageElectric
Heat (kW)No. of Stages
Nominal Heating (BTU/h)Total
Watts6
Total Amps
Min. Circuit Ampacity²
MOP4 (amps)
Power Cord
@ 230V @ 208V @ 265V
230/208V 2.5 1 8,500 6,800 - - 2,570 / 2,115 11.2 / 10.1 14.0 15 6-15 P
230/208V 3.5 1 12,000 9,900 - - 3,570 / 2,935 15.5 / 14.1 19.4 20 6-20 P
230/208V 5 1 17,100 14,000 - - 5,070 / 4,160 22.1 / 20.0 27.5 30 6-30 P
265V 2.5 1 - - - - 8,500 2,570 9.7 12.1 15 7-20 P
265V 3.7 1 - - - - 12,600 3,770 14.2 17.8 20 7-20 P
265V 5 1 - - - - 17,100 5,070 19.2 23.9 25 7-30 P
10 www.amana-ptac.com MC-DPTAC
accessories
14⅛"42"
161 /1
6"
StandaRd outdooR gRille
SGK01B SinglePack
SGK01TB StonewoodBeige
aRChiteCtuRal outdooR gRille
AGK01CB AnodizedAluminum(Silver)
AGK01DB DarkBronze/Brown
AGK01TB StonewoodBeige
AGK01WB AmanaWhite
AGK01SB CustomColors
PGK01DB DarkBronze/Brown
PGK01TB StonewoodBeige
PGK01TB AmanaWhite
PWHK01C Wire Harness Kit
Wall SleeveS
Allourwall sleeveshave industry standarddimensionsof42”wide x16⅟₁₆”high. All Stonewood Beige G-90 metal wall sleeves are thermally insulatedand include a weather board for use during construction. The WS900D, SCandINTERNAL14⅛”depthistheindustrystandard. Sleevesmaybeshippedseparatelytoallowforinstallationduringconstruction.
outdooR gRilleS
Availableinstamped-aluminumorarchitecturallylouveredforapplicationwithanAmanabrandWS900Dwallsleeve.AGK—Extrudedaluminumarchitecturalgrilleavailablewithanodizedalu-
minumfinishorabaked-onpaintfinishfordurability.Choosefrom3stockcolorsoracustomcolortoblendwithyourbuilding’sexteriorcolorscheme.Colorsinclude:CB(ClearAnodized),DB(DarkBrown/Bronze),TB(StonewoodBeige),WB(White),SB(Special/CustomColors)
PGK—One-pieceinjectionmoldedgrilleusingapolymerblendofengi-neeredthermoplastichigh-impactstrengthmaterialwithchemicalresistanceandanexteriorUVprotectivecoating.Choosefrom3stockcolors:DB(DarkBrown/Bronze),TB(StonewoodBeige),WB(White)
Skirting Skirting
Leveling Legs
Optional Fuse Holder Location
Optional Power Switch and Circuit Breaker Location
Power Receptacle
Subbase Box Assembly
PTSB320E 230/208V 15/20A
PTSB330E 230/208V 30A
PTSB420E 265V 15/20A
PTSB430E 265V 25A
PTSB000E Non-electrical
Sub-baSe Kit
The fully skirted sub-base concealswiringwhile providing strong support, ifneeded.Plug-inreceptacleandfield-wiringaccessspeedsinstallation.Electricalaccessories,suchasfuseholders,circuitbreakersanddisconnectswitches,meetN.E.C.requirements.
loW-voltage WiRe haRneSS Kit
Forquickconnectionsoftheremote,orwired,thermostats,wiredEMS,orfrontdeskwithjumpersandconnectors.
REK10B Remote Escutcheon Kit (10-pack)Remote eSCutCheon Kit (not ShoWn)Optionalkitforusewithunitscontrolledviaawired,remotethermostat.Coverscontroltouch-padforwiredthermostatinstallations.
Eachkitcontains80wiresandwirenuts,enoughtoattachathermostatandoneadditionalaccessoryto10PTACunits.Wirescomeinassortedcolorsforeasyattachment.
DK900DCondensate Drain Kit (use with WS900E)
DK9001D Condensate Drain Kit (use with WS900B)
CondenSate dRain Kit
Attachestothewallsleevebasepanforcontrolledinternalorexternaldisposalofcondensate.
DK900D
StandaRd dePth SleeveS
WS900E StandardPTACsleeve
WS900SC Seacoasttripleprotected
WS900D-INTERNAL
Internaldrainonlyforwindow-wallinstallations(DK900Dsoldseparately)
extRa deeP SleeveS
We offer sleeves in several depths for thickerwallinstallationsorspecialroomconfigurations
WS9xxD1 16”to24”in1”increments
WS928D1 Extradeep28”
WS930D1 Extradeep30”
WS936D1 Extradeep36”
AGK or
PGK
SGK
PTPWHWK4 Armored Cable - all voltages
PTQC03A Quick Connect - 230/208 V
PTQC04A Quick Connect - 265 & 115 V
haRd-WiRe KitS
Usedtopermanentlywiretothechassiswhenastandardsub-baseandpowercordarenotused.
LL2B Leveling legs for WS9** sleeves
leveling legS
Giveswallsleevefrontsupportandhelpstoleveltheunitforinstallation.
MC-DPTAC www.amana-ptac.com 11
accessories (conT.)
FHK315C 230/208V 15A
FHK315E 230/208V 15A (R-410A)
FHK320C 230/208V 20A
FHK320E 230/208V 20A (R-410A)
FHK330C 230/208V 30A
FHK330E 230/208V 30A (R-410A)
fuSe holdeR Kit
Cartridge-stylefusescanbeinstalledinthefuseholderforuseinthesub-baseorchassis.Availablein15,20and30amp(includedon265-voltunit).
CBK3**C Circuit Breaker KitCiRCuit bReaKeR Kit (230/208v only) Thecircuitbreakerkit,availablein15,20or30amp,canbeusedwithAmanabrandsub-bases.Itgivesovercurrentprotection,anditslocationallowsyoutoturntheunitonoroffwithouttools.
Basepan
Condenser
Condenser BafflesDGK1B Condenser Baffle Kit
CondenSeR baffle Kit
For use on non-baffled grilles. These deflectors direct the air in toward thecenterandawayfromtheinlettopreventrecirculationofthehotcondenserair.
PSHW03A 230/208V
PSHW04A 265V
PoWeR diSConneCt SWitCh
ThePSHW**Apowerdisconnectswitchcanbeusedfor265-voltor230/208-voltphysicaldisconnect,whererequiredbylocalcodes.Theswitchisratedat30-ampcapacity.TheswitchisforusewithandAmana®brandstandardsub-basesorPTPWHWK4HardWireKit.
MDK02B Main Duct – R-22
MDK01E Main Duct – R-410A
EDK02B Extension Duct
duCt extenSion Kit
Extendsairdistributiontoanadjoiningroom.Consistsofamainductfortheroomoforiginandanextensionducttoreachtheadjoiningroomandterminalduct.PTDK01Aallowsforthenew“B”seriesunittoworkwiththe“A”seriesductkits.
Extension Duct Kit
TRANSITION BAFFLES
Main Duct Kit
Terminal Duct Kit
TDK02B Terminal Duct
PTDK01A Transition Duct Only – R-22
PTDK01E Transition Duct Only – R-410A
PVK3A 230/208V – R-22
PVK4A 265V – R-22
PoWeR vent Kit
InstallationofPowerVentincreasesCFMuptoapproximately95.Ventdoorwillautomaticallyclosewhenunitfanisoff.
R-410Amodelsmusthavethesekitsinstalledatthefactory.
CDP302 230/208V – R-22
CDP402 265V – R-22
CDP302E 230/208V – R-410A
CondenSate Removal PumP Canbefield-installed.Assistsinremovingcondensatedevelopedbyheatpumpoperationand transfers it to indoorcoil todissipate into roomwhileaddinghumiditytotheroom.
Sub-baSe extenSion CoveR Kit
Convertsolder30-ampsub-basestoallowforinstallationofthelarger30-ampLCDIpowercordandplugs.
SBEC10A 10 Pack
12 www.amana-ptac.com MC-DPTAC
accessories (conT.)
ModelHeat
StagesCool
StagesDisplay Type
Shape & Orientation
D9945801 2** 1 Mech. Manual Rect./Horiz.1246001 1* 1 Digital Manual Rect./Horiz.1246003 2** 1 Digital Manual Rect./Horiz.
theRmoStatS
The following thermostats offer remote control. Any thermostat other thanthoselistedmustbesubmittedtoGoodmanCompany,L.P.,forapprovalpriortouse.
PDK3A 230/208V – R-22
PDK4A 265V – R-22
PDK3E 230/208V – R-410A
PDK4E 265V – R-410A
PoWeR dooR Kit Ventdoorwillautomaticallyopenwhenunitfanison.
HWK03B Hydronic Water Kit – R-22
HVK03B Hydronic Steam Kit – R-22
HWK03E Hydronic Water Kit – R-410A
HVK03E Hydronic Steam Kit – R-410A
hydRoniC heat Kit
Add-on kits fit all units allowing the additionof hydronicwater or hydronicsteamheat to cooling andheatingunits. The kits feature left- or right-handpiping.Unitretainscompleteserviceaccesswithakitinstalled.Unitmustbeconnectedtoandoperatedbyawallthermostat.
Hydronic Heat Kit-Top View
Hydronic Heat Kit-Right View
Hydronic Heat Kit-Side View
VS2WNCA* 2-way/24V/NC/Steam
VS2WNOA* 2-way/24V/NO/Steam
VW2WNCA* 2-way/24V/NC/End Switch
VW2WNOA* 2-way/24V/NO/End Switch
VW3WNC2B* 3-way/24V/NC/NO/End Switch
* Pop-top Actuator
hydRoniC valveS
WaterandsteamvalvesareavailableforusewiththeHWK03(water)andHVK03(steam)heatkits.
KL03B Security Key Lock (R-22)
KL03E Security Key Lock (R-410A)
SeCuRity Key loCKS
Inconjunctionwiththetamper-resistantfront,theinstallationofAmana®brandsecuritykeylockspreventstamperingofthecontrolsusedtosettemperature,heatingandcoolingfunctions.ULapprovedforinstitutionaluseonly.
RTS03 Remote wall-mounted sensorRemote temPeRatuRe SenSoR
Unit can bewired to sense room temperature away from the PTAC to haveaccuratereadings.
DS01E Thermostat: 2-way communications
DD01E Occupancy Sensor: EMS activation
DT01A Antennae / Router
GT01A Generic Radio Antenna / Router
DD01F Door Switch: EMS Activation
DP01E Web-enabled Platform Server
DL01E Web-enabled Platform Server Link
WiReleSS Rf (Radio fRequenCy) ContRolS
AllDigiSmartPTACscomefactory-readytobecontrolledviawirelessRFdevices.2.4Ghz80215.4protocolassuresrobustcommunicationsandresponse.
MC-DPTAC www.amana-ptac.com 13
accessories (conT.)WEMR01W Recess-mounted door switch
WEMS01B Surface-mounted door switch (Brown)
WEMS01W Surface-mounted door switch (White)
WiRed eneRgy management ContRol
Includes PIR occupancy sensor power from the DigiSmart control and doorswitch;cannotbeusedwitharemotewiredthermostat.
SECM1001AClimate Master 12½” Sleeve Extension (10 Pack)
SEZA0501AZone Aire 11½” Sleeve Extension (5 Pack)
Wall Sleeve extenSion adaPteR KitS
Room-sideextensionkitstoincreasethedepthoftheexistingsleevetoallowforanindustry-standardPTACtobeinstalled.
PTCB10B 10 Pack for R-22 units
PTCB10E 10 Pack for R-410A units
CuRtain baffle Kit
Thecolor-matchedpolymercurtainbaffleshelptopreventcurtainsfromfallinginto thedischarge air streamand causing recirculation, reducing efficienciesandshorteningcompressorlife.
inTake air filTersIt isextremely important toclean the inletairfiltersonceamonth (ormoreoften ifoperated industyordirty locationsorconditions)toproperlymaintaintheoperationalperformanceofthePTACunit.Thetwointakeairfilters(constructedofdurablepolypropylene)canbeeasilyinsertedintothecabinetfrontusingthecabinetfilterguides.Beforecleaningtheintakefilters,turntheunitoffbysettingthemodeswitchtotheOFFposition.Filtersshouldbecleanedasrequired.Thefollowingprocedureisusedtoremovetheintakefilters:1.Facingtheunit,pulluponthefilterhandleslocatedatthefronttopoftheunit.2.Pulleachfilterupwardandremove.3.Cleanfilterswithvacuumorwithrunningwater.Reversethisproceduretoreinstallthefilters.
Note:Accessoryfilterkitsareavailablefromyoursalesperson.Allfiltersarepermanentandcleanable.ConsultyourI&OManualforothermonthlycleaninginstructions.
monTHly mainTenance
sPare filTers Helpskeepdirtandlintoutoftheairandoffthecoil,thus increasing the unit's efficiency. Amana® brandfiltersareeasytoremove,washandreplace.
FK10A 10-pack - A Series
FK10B 10-pack - B, C & D Series
FK10E 10-pack - E Series (This model requires 2 filters per change.)
rePlacemenT cHarcoal filTer kiTAbsorbs airborne odors caused by cigarette, pipeor cigar smoke and odors caused by mold, mildew,etc. Filters are made of polyester fibers coated withactivatedcharcoalandareindividuallywrapped.Thesefilters are permanent and canbewashedor cleaned.CallyourAmana®brandPTACsalespersonfordetails.10filtersperpack.
CFK10A 10-pack - A Series (R-22)
CFK10B 10-pack - B, C & D Series (R-22)
14 www.amana-ptac.com MC-DPTAC
uniT wiTH accessory wall sleeve and suB-Base accessory
3 "
1"1"
6 - 1 / 8" 9 - 9 / 16"24 - 5 / 16"
40"
42"
Location of external drain holes on bottom flange of Wall Sleeve
3" Clearanceto side walls
AirFlow
AirFlow
AirFlow
Air Discharge Grille ControlDoor
ToP view
11-3/8"
40°
21-1/2"
1 -3 /8"13/16"
14-1/8"
4"
2-3/4"
15°
7-3/8"
1/2" O.D.COPPER
DRAIN TUBE
AIR DISCHARGE GRILLE IS REVERSIBLE TO PROVIDE EITHER 15° OR 40° DISCHARGE ANGLE
HINGED CONTROL
DOOR
OPTIONALSUBBASE
13/16"
7/8"STAMPED GRILLE
1-3/8"ARCH GRILLE
WALL SLEEVE
16-1/16"
rigHT view
fronT view
58” lcdi cord seT — 230v/208v uniT*
58" CORD SET 230V/208V UNIT*
18" CORD SET 265V UNIT*
3-1/4" MIN
2"MAX
2-5/8"
42"
16-1/16"
R IGHTLEFT
1" AND 3/4" CONCENTRIC KNOCKOUTS BACK & BOTTOM OF SUBBASE (ELECTRICAL ONLY)
MC-DPTAC www.amana-ptac.com 15
FINISHED FLOOR
42 1/4"
16 1/4" MIN
MAIN STUD
JACK STUDS
HEADER - 4" x 4" OR DOUBLE 2"x 4" ON EDGE
SUB-FLOOR
CRIPPLE
JACK STUD
ADJUST FRAMING TO SECURE THIS DIMENSION
framing for accessory wall sleeve (ws9XX)
Wall sleeve opening height should be squared with wall sleeve opening width.
H = 16¼"
W = 42¼"
Fastening Wall SleeveWhen installed in an opening, the Wall Sleeve must be horizontally level (side-to-side) and pitched ¼ bubble to the outside.
(NOTE: To ensure unit’s maximum efficiency, DO NOT over- or under-pitch.)
Installation Notes1. If Sub-base (PTSB***E) is installed, allow minimum 3¼” height clearance and maximum 5” height clearance between wall sleeve and floor; allow minimum
2¾” protrusion from a finished wall. See Note 4 if using hydronic units.2. Drain Kit (DK900D) shipped separately. Can be mounted either right side, left side or bottom of sleeve. If mounted to bottom of sleeve, allow 2” height
clearance from floor to bottom of sleeve.3. For UL approval, 265V units must use Amana® brand Sub-base (PTSB***E) or Amana® brand Hard Wire Kit (PSHW04A). Overcurrent protection on 265V
units must be by cartridge-style time delay fuses, which are included and factory-installed on the Amana® brand 265V chassis.4. If Hydronic Kit (HWK03 or HVK03) is installed, Wall Sleeve must extend exactly 3" into the room from the finished interior wall. If using the Amana® brand
Sub-base (PTSB***E), only the minimum 3¼” height clearance between wall sleeve and floor is permissible. Unit must also be operated with a remote-mounted thermostat.
5. If Duct Kit (MDK***) is installed, allow a minimum of 2⅜” into the room from the finished interior wall.
MountingHoles(Drilled by Installer)
PlasticAnchor
Screws
ExpansionAnchor Bolt
Toggle BoltWood Screw
AlternativeFastening Method(Field Supplied)
Wall Sleeve must extend a minimum of ¼” beyond outside wall to allow for proper caulking.
16 www.amana-ptac.com MC-DPTAC
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commit- ment to quality products may mean a change in specifications without notice. © 2012 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
Packaged Terminal air condiTioners and HeaT PumPs
wiTH conTrol Board
7-Button Control Pad• One-TouchActivation• TotalFanControl• Easy-to-ReadDisplay
AssembledintheUSAfor30years:Unitsare100%run-testedandtriple-testedforleakage.
First-YearWarranty:Parts&LaboronentireunitSecondthroughFifthYear:Parts&LaboroncertainsealedsystemcomponentsSecondthroughFifthYear:oncertainfunctionalpartsonly* Completewarrantydetailsavailablefromyourlocaldealeror
atwww.amana-ptac.com.