5
PSA SERIES Version: 1.2.0 | Published February 05, 2014 | All specifications are subject to change without notice. © 2014 White Knight Fluid Handling, Inc. Our engineers are easy to work with and ready to perform your custom testing. Contact us at info@wkfluidhandling.com or 435.783.6040, or visit wkfluidhandling.com PSASD pumps are dry-run capable and can be run dry for more than one hour without damage to the pump. PSASD specifications and performance data are available at wkfluidhandling.com/psa. Dry-Run Capable PSA Series Pumps 100% PTFE & PFA in liquid path Polypropylene heads, ceramic in air shuttle valve No metal parts, no o-rings; No lubrication in air shuttle or shift mechanisms Virtually any style or size liquid connection without NPT threads Patented Pneumatic Logic ® minimizes liquid pulsation and pump vibration Safe, leak-free operation Minimal parts for durable design Class 100 clean room assembly, testing, packaging Easy to install and service No maintenance required during two year warranty Robust Design Provides Ultra Reliable Chemical Delivery and Recirculation Proven reliable design for the harshest recirculation and delivery applications SHIFT METHOD SHIFT METHOD SHUTTLE VALVE SHUTTLE VALVE PUMP TYPE PUMP TYPE DOUBLE BELLOWS DOUBLE BELLOWS UP TO 100˚C 212˚F UP TO 100˚C 212˚F TEMPERATURE TEMPERATURE ULTRA HIGH ULTRA HIGH PURITY PURITY PSA030 PSA060 PSA140 Leak detection, electronic controls and/or monitoring; pulse dampener Options Features and Benefits 2 2 UP TO 7 BAR / 100 PSI UP TO 7 BAR / 100 PSI RECIRC. / DELIVERY RECIRC. / DELIVERY The PSA series provides a 100% PTFE/PFA fluid path and operates with the unique White Knight shuttle valve eliminating the need for complicated detents and manual resets and is the ideal solution for ambient temperature, ultra-high purity recirculation and delivery applications demanding White Knight consistency.

PSA SERIES - teknopoli · and performance data are available at wkfluidhandling.com/psa. Dry-Run Capable PSA Series Pumps ... 240 CPM 200 CPM 160 CPM 100 CPM 2.5 SCFM 5 …

Embed Size (px)

Citation preview

PSA SERIES

Version: 1.2.0 | Published February 05, 2014 | All specifications are subject to change without notice. © 2014 White Knight Fluid Handling, Inc.

Our engineers are easy to work with and ready to perform your custom testing. Contact us at [email protected] or 435.783.6040, or visit wkfluidhandling.com

PSASD pumps are dry-run capable and can be run dry for more than one hour without damage to the pump. PSASD specifications and performance data are available at wkfluidhandling.com/psa.

Dry-Run Capable PSA Series Pumps

• 100% PTFE & PFA in liquid path

• Polypropylene heads, ceramic in air shuttle valve

• No metal parts, no o-rings; No lubrication in air shuttle or shift mechanisms

• Virtually any style or size liquid connection without NPT threads

• Patented Pneumatic Logic® minimizes liquid pulsation and pump vibration

• Safe, leak-free operation

• Minimal parts for durable design

• Class 100 clean room assembly, testing, packaging

• Easy to install and service

• No maintenance required during two year warranty

Robust Design Provides Ultra Reliable Chemical Delivery and RecirculationProven reliable design for the harshest recirculation and delivery applications

SHIFT METHODSHIFT METHOD

SHUTTLE VALVESHUTTLE VALVE

PUMP TYPEPUMP TYPE

DOUBLE BELLOWSDOUBLE BELLOWS

UP TO

100˚C212˚F

UP TO

100˚C212˚F

TEMPERATURETEMPERATURE

ULTRA HIGHULTRA HIGH

PURITYPURITY

PSA030 • PSA060 • PSA140

Leak detection, electronic controls and/or monitoring; pulse dampenerOptions

Features and Benefits

22

UP TO 7 BAR / 100 PSIUP TO 7 BAR / 100 PSI

RECIRC. / DELIVERYRECIRC. / DELIVERY

The PSA series provides a 100% PTFE/PFA fluid path and operates with the unique White Knight shuttle valve eliminating the need for complicated detents and manual resets and is the ideal solution for ambient temperature, ultra-high purity recirculation and delivery applications demanding White Knight consistency.

PSA SERIES

Version: 1.2.0 | Published February 05, 2014 | All specifications are subject to change without notice. © 2014 White Knight Fluid Handling, Inc.

Our engineers are easy to work with and ready to perform your custom testing. Contact us at [email protected] or 435.783.6040, or visit wkfluidhandling.com

Specifications

PSA030 • PSA060 • PSA140

Left Side

Right Side

Detent-free shuttle valve design has one moving part, enhancing reliability.

Exhaust Air

Supply Air

Shift Air

Ambient Air

Liquid

Air-Side Operation

White Knight Fluid Handling leads the industry in quality through controlled, consistent, in-house engineering, manufacturing, assembly, testing, packaging and product rebuild. We know your reputation is on the line when you specify our products. So, we execute all manufacturing in house, including raw materials pressing, sintering, precision machining and performance testing.

TOTAL QUALITY CONTROL

MODEL

MAX FLOW RATE*

SIZE OF AIR CONNECTION

DISPLACEMENT PER CYCLE*

CYCLES PER MIN*

FLUID PATH MATERIALS

NON-FLUID PATH MATERIALS

WEIGHT

SUCTION LIFT*

SOUND**

PRESSURE POWER

PSA030 24.7 LPM 6.53 GPM 1/4” FNPT 0.074 Liters

0.019 Gallons 333 max PTFE / PFA PTFE / PFA / PP / Ceramic

3.30 KG7.28 LBS

1 Meter 3 Feet

74.00 dB(a) 79.90 dB(a)

63.01 dB(a) 69.90 dB(a)

PSA060 62.3 LPM 16.46 GPM 1/4” FNPT 0.178 Liters

0.047 Gallons 348 max PTFE / PFA PTFE / PFA / PP / Ceramic

4.70 KG10.36 LBS

1 Meter 3 Feet

73.11 dB(a) 82.50 dB(a)

64.29 dB(a) 74.11 dB(a)

PSA140 123 LPM 32.5 GPM 3/8” FNPT 0.500 Liters

0.132 Gallons 273 max PTFE / PFA PTFE / PFA / PP / Ceramic

16.60 KG36.60 LBS

1 Meter 3 Feet

81.98 dB(a) 91.60 dB(a)

76.37 dB(a) 83.16 dB(a)

*May vary depending on configuration. Suction lift diminishes over time. Recommended installation level less than 3’ above source.**dB Level at 100PSI 50CPM (top) and 100PSI maximum CPM (bottom). Sound Levels measured in accordance with ISO9614-2:1997.***Dry-run capable PSASD030 and PSASD060 pumps require flooded suction and may have a reduced warranty. Details at wkfluidhandling.com.

Control and Monitoring Connection OptionsType Stroke Detection Leak Detection

Electric Control

Method Fiber OpticProximity

Switch

Solid State Pressure Switch

Fiber OpticConductivity

ModelD10

SensorWith

SensorWith

SensorWithout Sensor

PSA030 X X x x x x x

PSA060 X X x x x x x

PSA140 X X x x x x x

Air Supply/Fluid Temperature Limitations

5.9

6.3

6.7

7.1

5.5BarPSI

84

88

92

96

100

80

Air

Supp

ly P

ress

ure

144° 154° 165° 176° 187° 198° 208° 212°Fahrenheit

62° 68° 74° 80° 86° 92° 98° 100°Celsius

PSA SERIES

Version: 1.2.0 | Published February 05, 2014 | All specifications are subject to change without notice. © 2014 White Knight Fluid Handling, Inc.

Our engineers are easy to work with and ready to perform your custom testing. Contact us at [email protected] or 435.783.6040, or visit wkfluidhandling.com

PSA030 Performance Curves

1

2

3

4

5

6

7

BarPSI

10

20

30

40

50

60

70

80

90

100

20 PSI

40 PSI

60 PSI

80 PSI

100 PSI

Liqu

id O

utle

t Lin

e Pr

essu

re

Liquid Flowrate1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0GPM

0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0m3/hr

5 10 15 20 25 30 35LPM

280 CPM

240 CPM

200 CPM

160 CPM

100 CPM

2.5 SCFM

5 SCFM

7.5 SCFM

10 SCFM

12.5 SCFM

Cycle RateAir ConsumptionLiquid Flowrate

PSA030 Dimensions

PSA030

21.8

572.2

1003.9

662.6

1054.1

2148.4

2349.2

1214.8

321.3

311.2

512.0

11.4

622.5

251.0

1114.4

MOUNT WITH 2 EA.3/8" (10 mm) SOCKETHEAD CAP SCREWS

CL

Dimensions in [millimeters] inches

PSA SERIES

Version: 1.2.0 | Published February 05, 2014 | All specifications are subject to change without notice. © 2014 White Knight Fluid Handling, Inc.

Our engineers are easy to work with and ready to perform your custom testing. Contact us at [email protected] or 435.783.6040, or visit wkfluidhandling.com

PSA060

753.0

1275.0

793.1

8.3

371.5

1546.1

1405.5

25910.2

27010.6

461.8

512.0

10.4

913.6

19.7

1355.3

MOUNT WITH 2 EA.3/8" (10 mm) SOCKETHEAD CAP SCREWS

CL

1

2

3

4

5

6

7

BarPSI

10

20

30

40

50

60

70

80

90

100

20 PSI

40 PSI

60 PSI

80 PSI

100 PSI

Liqu

id O

utle

t Lin

e Pr

essu

re

Liquid FlowrateGPM 1 2 3 4 65 7 8 9 1110 12 13 14 15 16 17 18

m3/hr 2.01.51.00.5 2.5 3.0 3.5 4.0

10 20 30 40 50 60 70LPM

280 CPM

240 CPM

200 CPM

160 CPM

100 CPM

5 SCFM

10 SCFM

15 SCFM

20 SCFM

Cycle RateAir ConsumptionLiquid Flowrate

Dimensions in [millimeters] inches

PSA060 Performance Curves

PSA060 Dimensions

PSA SERIES

Version: 1.2.0 | Published February 05, 2014 | All specifications are subject to change without notice. © 2014 White Knight Fluid Handling, Inc.

Our engineers are easy to work with and ready to perform your custom testing. Contact us at [email protected] or 435.783.6040, or visit wkfluidhandling.com

PSA140

1

2

3

4

5

6

7

BarPSI

10

20

30

40

50

60

70

80

90

100

20 PSI

40 PSI

60 PSI

80 PSI

100 PSI

Liqu

id O

utle

t Lin

e Pr

essu

re

Liquid FlowrateGPM 2 4 6 8 1210 14 16 18 2220 24 26 28 30 32 34 36

m3/hr 4.03.02.01.0 5.0 6.0 7.0 8.0

20 40 60 80 100 120 140LPM

240 CPM

220 CPM

200 CPM

160 CPM

130 CPM

100 CPM

10 SCFM

15 SCFM

20 SCFM

25 SCFM

30 SCFM

35 SCFM

Cycle RateAir ConsumptionLiquid Flowrate

2068.1

753.0

8.3

1385.4

34513.6

2228.7

36114.2

532.1

2339.2

512.0

471.8

572.2

2158.4

11.4

943.7

MOUNT WITH 2 EA.3/8" (10 mm) SOCKETHEAD CAP SCREWS

CL

Dimensions in [millimeters] inches

PSA140 Performance Curves