Strategic Power Solutions
®
Online UPS 3 Phase Out
= Lower space and weight
= Delivers unity output power (KVA=KW ) providing the maximum power capacity to mission critical loads.
= High overload capacity
= Each Module can be field upgradable up to 30KVA/KW (15-20-25-30)
= Autonomous Start-up (independent from the central display)
= Modular design is applied in power module, STS module and Battery module. It will simplify maintenance and replacement with low MTTR.
= 3-Level IGBT based Rectifier and Inverter
= True Online Double Conversion (VFI-SS-111),
= High reliable operation with redundant power supply in STS
= Efficiency double conversion up to 96.5% & ECO mode up to 99%
= Idle Mode Save Power
= 10" colour Touch Screen display for user friendly monitoring
= Intelligent and innovative Self Aging Test
= Isolated airflow with redundant fans
= Flexible battery configuration, adjust, battery numbers 32 - 40 Pcs. per string.
= Isolation Transformer Compatible
PS Series Modular UPS15-300KVA/15-300KW 3:3 Phase, Output PF=1.0
The PS series delivers the best combination of reliability, hot-swappable and flexibility. The PS series modular UPS provides the most compact footprint of less than 2 sqm saves commercial space.
PS series (3Phase In & 3Phase Out) modular True online UPS for sensitive equipments. Scalable architecture allows you to optimize cost effective solution to meet power demands by vertically expanding in a single rack enclosure from 15KVA to 300KVA and achieve N+1 or N+X redundancy in the same rack, parallelling to go up to 900KVA system with the advanced 3-Level IGBT, DSP control technology.
PS series is considered to be the best power protection solution for data centres, as well as for PC & server, storage and Telecom Network equipments.
10" Touch Screen
Features:
ISO 9001:2008 ISO 14001:2004 ISO 27001:2013OHSAS 18001:2007
Power Module
3U
Strategic Power Solutions
®
RACK MODEL PSR30U06081012M3U PSR30U09121518M3U PSR42U12162024M3U PSR42U15202530M3U
Rating (KVA) 60 80 100 120 90 120 150 180 120 160 200 240 150 200 250 300
Dimension WxDxH (mm) 1100 x 600 x1475(30U) 1100 x 600 x 2010(42U)
Weight (Kg) 197 203 273 275
Max. Power Module No. 4 6 8 10
Module Configurations 15KVAx4 20KVAx4 25KVAx4 30KVAx4 15KVAx6 20KVAx6 25KVAx6 30KVAx6 15KVAx8 20KVAx8 25KVAx8 30KVAx8 15KVAx10 20KVAx10 25KVAx10 30KVAx10
Monitoring 10” Touch Screen Display
Maximum STS Capacity 150KVA 200KVA 275KVA 360KVA
Bypass Feature Hot-Swappable Inbuilt Static Bypass Module; Inbuilt Maintenance Bypass Switch
Bypass Voltage / Phase 380V / 400V / 415V AC + 15% (Optional + 5%, + 10%, + 25%) / (3Ph+N+PE)
Bypass Frequency ± 1Hz, ± 3Hz, ± 5Hz
Transfer Time ECO to Inverter Mode ≤ 2ms
Overload 105%~110% for 60 Min.; 110%~125% for 10 Min.; 126%~150% for 1 Min.; >150% for 200 ms
MODULE MODEL PSM3315L40U3 PSM3320L40U3 PSM3325L40U3 PMS3330L40U3Rating (KVA) 15 20 25 30Dimension WxDxH (mm) 440x650x132 (3U)Weight (Kg) 33.5 34 34.5 35
INPUT
Nominal Voltage / Phase 380V / 400V / 415V AC (3Ph+N+PE)
Operating Voltage Range 277V ~ 480V AC Load Dependent
Operating Frequency Range 40Hz ~ 70Hz, Auto Sensing
Power Factor ≥ 0.99
Harmonic Distortion (THDi) ≤ 3%
DG Input / Power Walking Support / 0~60 Sec ( Configurable)
OUTPUT
Output Voltage 380V / 400V / 415V AC (3Ph+N+PE)
Voltage Regulation ± 1%
Power Factor 1.0, KVA=KW, 20KVA=20KW, 25KVA=25KW, 30KVA=30KW
Output Wave Shape Pure Sine Wave
Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Crest Factor 3:1
Harmonic Distortion (THDv) ≤ 1% With Linear Load, ≤ 3% with Non-Linear Load
Overload ≥125% for 10 min, ≥150% for 1 min, ≥150% for 200 ms
Efficiency Up to 96.5% Dual Conversion Mode, 99% ECO Mode
BATTERY
Battery Voltage 384V DC (384 - 480V DC, Configurable)
Maximum Charging Current 8A Per Power Module
Battery Module (Optional) 20 Nos. of 12V/9Ah/7AH
SYSTEM FEATURE
Transfer Time Zero
Alarm / ProtectionsShort Circuit, Input Under/Over Voltage, Over Temperature, Over Current,
Over Load, DC BUS Under / Over Voltage and Battery low
Rating Upgradation Each Module can be field upgradable up to 30KVA/KW (15-20-25-30) thru Software (Optional)
Display LED
ENVIRONMENTAL
Temperature Operating: -5°C ~ 45°C, Storage: -10ºC ~ 55ºC
Humidity / Altitude 0~95% RH Non-condersing / <1500 M
Noise Level Low Audible Noise Level
STANDARDS
IP Class IP 20
Quality ISO 9001, ISO 14001, OHSAS 18001, ISO 27001, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard Rack: RS-232
Optional SNMP / ModBus / Dry Contact / Parallel Card / RS-485 / Dry Contact
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000 / Power Manager
*Specifications are subject to change without prior notice.** For additional information contact : [email protected]
Best Power Equipments (I) Pvt. Ltd.Corporate Office: G-240, Sector-63, Distt. Gautam Buddh Nagar, Noida-201307 UPRegistered Office: 812A, Shakuntala Building, 59, Nehru Place, New Delhi-110019PH: +91 120 4637000-0029 | Mobile: +91 9311995859 | Email: [email protected]@bpeeservices.com | Toll Free: 1800 103 1247 | Website: www.bpee.com
Strategic Power Solutions
®
Technical Specifications of PS Series 60~300KVA
Chromscience Sdn Bhd
HeadquarterS1-08-12, D’sara Sentral,KG Baru Sungai BulohSelangor-47000Tel: 03-64122261E-mail: [email protected]
BranchLot 18461, Jlnkubur Syatif,KG Padang Nenas, Kuala Nerus, Terengganu-21030Tel: 09-6699368Website: www.chromscience.com
Our Authorized Distributor