14
PRODUCT NOTES: THESE ARE THE STANDARD GEOPANEL CONFIGURATIONS. CONTACT GEOMETRIK FOR INFORMATION REGARDING CUSTOM SIZES. CUSTOM SIZES CAN BE UP TO 4'-0" WIDE X 8'-0" LONG. TYPICAL STEPS FOR CUTTING PANELS: 1. MEASURE NON-FULL SQUARE DIMENSIONS DESIRED. 2. DETERMINE PANEL SIDE EDGE TO BE CUT. 3. SELECT PROFILE TO BE CUT. 4. CUT PANEL TO DESIRED WIDTH/ LENGTH. 5. RE-PROFILE NECESSARY GROOVES AS PER PRIOR TO CUTTING. 6. REPLACE EDGE BANDING TO MATCH. 7. REFINISH EDGE BANDING TO MATCH. HOW TO READ PRODUCT "SKU" : PS-2816SP-CS MIDDLE SECTION REPRESENTS "PERFORATION TYPE" (EXAMPLE = 8mm HOLES @ 16mm CENTERS) LAST TWO NUMBERS REPRESENT CUSTOM SIZE "SKU" ABBREVIATIONS: PS = GEOPANEL PERFO S CS = CUSTOM SIZE SP = STANDARD PATTERN DP = DIAGONAL PATTERN 2200SL = SLOTTED PERFORATION 2300RS = ROUND SQUARE PERFORATION 1285 Stevens Road West Kelowna, BC, Canada V1Z 2S9 Ph.(250) 769-1500 Fax.(250) 769-1520 www.geometrik.com [email protected] Product: Description: Sheet No: Date: Drawn By: GEOPANEL PERFO S SKU INFORMATION TM MAR-31-2011

PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

PRODUCT NOTES:

THESE ARE THE STANDARD GEOPANEL CONFIGURATIONS.

CONTACT GEOMETRIK FOR INFORMATION REGARDING

CUSTOM SIZES.

CUSTOM SIZES CAN BE UP TO 4'-0" WIDE X 8'-0" LONG.

TYPICAL STEPS FOR CUTTING PANELS:

1. MEASURE NON-FULL SQUARE DIMENSIONS DESIRED.

2. DETERMINE PANEL SIDE EDGE TO BE CUT.

3. SELECT PROFILE TO BE CUT.

4. CUT PANEL TO DESIRED WIDTH/ LENGTH.

5. RE-PROFILE NECESSARY GROOVES AS PER PRIOR TO

CUTTING.

6. REPLACE EDGE BANDING TO MATCH.

7. REFINISH EDGE BANDING TO MATCH.

HOW TO READ PRODUCT "SKU" :

PS-2816SP-CS

MIDDLE SECTION REPRESENTS

"PERFORATION TYPE"

(EXAMPLE = 8mm HOLES @

16mm CENTERS)

LAST TWO

NUMBERS REPRESENT

CUSTOM SIZE

"SKU" ABBREVIATIONS:

PS = GEOPANEL PERFO S

CS = CUSTOM SIZE

SP = STANDARD PATTERN

DP = DIAGONAL PATTERN

2200SL = SLOTTED PERFORATION

2300RS = ROUND SQUARE PERFORATION

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SSKU INFORMATION

TMMAR-31-2011

Page 2: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

AS SPEC'D

AS

S

PE

C'D

SKU # PANEL SIZE PERFORATION

AS SPEC'D

AS

S

PE

C'D

CUSTOM SIZEPS-2832SP-CS 8mm HOLES @ 32mm O/C

SKU # PANEL SIZE PERFORATION

CUSTOM SIZEPS-2816SP-CS 8mm HOLES @ 16mm O/C

SKU # PANEL SIZE PERFORATION

CUSTOM SIZEPS-2316SP-CS 3mm HOLES @ 16mm O/C

ROUND PERFORATION - SQUARE PATTERN

ROUND PERFORATION - SQUARE PATTERN

ROUND PERFORATION - SQUARE PATTERN

AS SPEC'D

AS

S

PE

C'D

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SSTANDARD

CONFIGURATIONS

TMMAR-31-2011

Page 3: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

SKU # PANEL SIZE PERFORATION

CUSTOM SIZEPS-2300RS-CS 30mm X 30mm ROUNDED SQUARE

SKU # PANEL SIZE PERFORATION

CUSTOM SIZEPS-2200SL-CS 100mm X 10mm SLOT

SKU # PANEL SIZE PERFORATION

CUSTOM SIZEPS-2316DP-CS 3mm HOLES ON 16mm CENTERS

ROUND PERFORATION - DIAGONAL PATTERN

ROUND SQUARE PERFORATION - SQUARE PATTERN

AS SPEC'D

AS

S

PE

C'D

AS SPEC'D

AS

S

PE

C'D

AS SPEC'D

AS

S

PE

C'D

SLOTTED PERFORATION

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SSTANDARD

CONFIGURATIONS

TMMAR-31-2011

Page 4: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

MDF CORE BOARD

STANDARD PANEL THICKNESS = 3/4"

*OPTIONAL THICKNESS AVAILABLE.

VENEER EDGE BANDING TO

MATCH DECORATIVE FACE

VENEER TYPICAL.

DECORATIVE

FACE VENEER.

SLOTTED PERFORATIONS.

SIZES AND SPACING PER

PROJECT SPECIFICATION

HATCH INDICATES FACTORY

APPLIED BLACK ACOUSTIC

FABRIC TO B/S OF PANEL TYP.

SCALE:

1

-

N.T.S

BALANCING VENEER ON

BACK SIDE OF PANEL

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO STYPICAL WOOD PANEL

CONSTRUCTION

TMMAR-31-2011

Page 5: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

12 GA. WIRE PAINTED BLACK

(BY INSTALLER)

BLACK HEAVY DUTY 15/16 CROSS BAR

@ 4'-0" O.C. FOR LATERAL STABILITY

(BY INSTALLER)

3/8" - 1" REVEAL REQ'D. MIN

(SPEC'D BY ARCH)

GEOMETRIK

TORSION SPRING ASSEMBLY

5/8" MAX. WOOD SCREW

(BY INSTALLER)

BLACK HEAVY DUTY

15/16" MAIN T-BAR

@ 2'-0" O.C. (BY INSTALLER)

1" PERIMETER

REVEAL REQ'D. TYP.

WA

LL

GEOMETRIK WOOD

CEILING PANEL TYP.

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO STORSION SPRING

SUSPENSION SYSTEM

TMMAR-31-2011

Page 6: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

1" REVEAL

WA

LL

3/8" - 1" REVEAL REQ'D. MIN

(SPEC'D BY ARCH)

GEOPANEL PERFO S

CEILING PANEL TYP.

Z-HANGER TYP.

(BY GEOMETRIK)

5/8" MAX. WOOD SCREW

(BY INSTALLER)

12 GA. WIRE PAINTED BLACK

(BY INSTALLER)

C-CHANNEL

(BY INSTALLER)

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SZ-HANGER

SUSPENSION

TMMAR-31-2011

Page 7: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

3/8" - 1" REVEAL REQ'D. MIN

(AS SPEC'D BY ARCH)

1 1/2 " CHANNEL(BY INSTALLER)

GEOMETRIK Z-HANGER, FIELD

ATTACHED TO DESIGNATED LOCATION

ON BACK OF CEILING PANEL

6" MAX 6" MAX

GEOPANEL S CEILING PANEL

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SZ-HANGER

SUSPENSION SYSTEM

TMMAR-31-2011

Page 8: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

APPROVED LIGHT FIXTURE

(BY OTHERS)

INDEPENDENT SUSPENSION WIRE FOR

LIGHT FIXTURE (BY OTHERS)

FINISHED TRIM (SUPPLIED BY LIGHT MFR.

INSTALLED BY OTHERS)

FIELD CUT OPENING IN PANEL FOR

LIGHT FIXTURE (BY INSTALLER)

GEOPANEL PERFO S WOOD ACOUSTICAL

CEILING PANEL (BY GEOMETRIK)

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SPOT LIGHT

INSTALLATION

TMMAR-31-2011

Page 9: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

APPROVED

LIGHT FIXTURE

(BY OTHERS)

BRACKETING FOR

LATERAL STABILITY

ONLY (BY INSTALLER)

INDEPENDENT SUSPENSION WIRE FOR

LIGHT FIXTURE (BY OTHERS)

BLACK HEAVY DUTY 15/16"

T-BAR GRID @ 24" [600mm] O.C.

(CROSS TEE'S NOT SHOWN).

* CUT PANELS MAY HANG

UNSUPPORTED A MAXIMUM

OF 6" FROM NEAREST T BAR CLIP.

TORSION SPRING CLIP ASSEMBLY.

REQ'D FOR PANEL TO BE DEMOUNTABLE.

FIELD CUT OPENING IN PANEL FOR

LIGHT FIXTURE (BY INSTALLER)

BOTTOM OF LIGHT FIXTURE TO BE

INDEPENDENT OF PANEL. LIGHT FIXTURE

COVER PLATE TO CONCEAL CUT OPENING IN

PANEL.

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SPOTLIGHT

CEILING INSTALL

TMMAR-31-2011

Page 10: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

WOOD FURRING

PAINTED BLACK (BY INSTALLER)

3/4

"

11/2" THICK ACOUSTICAL

INSULATION

WOOD TRIM BY INSTALLER

OR GEOMETRIK

REVEAL REQ'D. MIN

(AS SPEC'D BY ARCH)

GEOMETRIK GEOPANEL

PERFO S WALL PANEL

WALL

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SWALL PANEL

INSTALLATION DETAIL

TMMAR-31-2011

Page 11: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

3/8" - 1" REVEAL REQ'D. MIN

(AS SPEC'D BY ARCH)

WOOD FURRING PAINTED BLACK

(BY INSTALLER) @ 24" O/C THICKNESS

DETERMINED BY DESIRED NRC RATING.

Z-CLIPS ATTACHED TO BACK OF

PANEL AND WOOD FURRING

(BY INSTALLER)

BLACK FOAM SPACER AS PER REVEAL

SIZE REQ'D. AS PER ARCH SPEC

(BY INSTALLER)

GEOMETRIK WOOD WALL PANEL

WALL

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SWALL Z-CLIP

ATTACHMENT

TMMAR-31-2011

Page 12: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

1" [25.4mm] SPACE REQUIRED BETWEEN

CEILING & PANEL FOR INSTALLATION. PANEL

DROPS 1" AFTER ENGAGING WITH WALL CLIP

GEOPANEL PERFO S

WALL PANEL

3/8

" R

EV

EA

L

MONARCH Z-CLIP

or EQUAL TYP.

1/2" x 2" WOOD FURRING STRIP TYP. (BY INSTALLER)

THICKNESS DETERMINED BY DESIRED NRC RATING.

BLACK NEOPRENE STRIPPING

BETWEEN PANELS AS PER

ARCH. SPEC (BY INSTALLER).

WA

LL

WA

LL

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SZ-CLIP

ATTACHMENT DETAIL

TMMAR-31-2011

Page 13: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

DIRECT SCREWS ATTACHMENT THROUGH "BLIND" HOLES WITH

BLACK SCREWS (BY INSTALLER) MIN. 4 SCREWS PER PANEL & 4

"BLIND" HOLES PER PANEL EDGE TYP.

FACTORY APPLIED BLACK

ACOUSTIC FABRIC TO B/S OF

PANEL TYP.

FACTORY ATTACHED MATCHING

EDGE BANDING TYP; FIELD APPLIED WERE

FIELD CUTS OCCUR (BY INSTALLER)

4" WIDE BLACK WOOD FURRING (BY INSTALLER) - 2' O.C.;

THICKNESS DETERMINED BY DESIRED NRC RATING.

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SWALL ATTACHMENT

DETAIL

TMMAR-31-2011

Page 14: PS-2816SP-CS · 3/4" 11/2" THICK ACOUSTICAL INSULATION WOOD TRIM BY INSTALLER OR GEOMETRIK REVEAL REQ'D. MIN GEOMETRIK GEOPANEL (AS SPEC'D BY ARCH) PERFO S WALL PANEL WALL 1285 Stevens

3/4" x4" ON FLAT (BLACK) WOOD

FURRING (BY INSTALLER) @ 24" O.C.

THICKNESS DETERMINED BY DESIRED

NRC RATING.

2'-0" [609.6]

VARIES PER PANEL SIZE

INDICATES FACTORY DRILLED "BLIND"

HOLES FOR WALL PANEL ATTACHMENT

(4) SCREWS PER PANEL EDGE.

3/8

" [9

.5

]

GA

P A

S P

ER

A

RC

H S

PE

C

3/8" [9.5mm] GAP TO MATCH CEILING

PANEL GAP AS REQ'D.

HIDDEN LINE INDICATES WOOD

FURRING BEYOND.

1285 Stevens RoadWest Kelowna, BC, CanadaV1Z 2S9Ph.(250) 769-1500 Fax.(250) 769-1520www.geometrik.com [email protected]

Product:Description: Sheet No:

Date: Drawn By:

GEOPANEL PERFO SWALL PANEL

ATTACHMENT DETAIL

TMMAR-31-2011