There are many levels of protection and
system sophistication on offer to suit most
budgets from manual start petrol fire pumps
to remote start diesel units that can be
operated by mobile phone. This cost can be
incorporated into the purchaser's mortgage if
installed during the construction phase.
Small Farm Services uses
top quality components
and materials which
increase reliability and
reduce maintenance to a
minimum. Externally
mounted systems are available for existing
dwellings
Full technical support and servicing is offered by
Small Farm Services
The majority of house fires started by ember
attack, start in the gutters. Sprinkler systems
designed to protect buildings from ember attack
can be fitted to the roof, veranda's, decked areas
as well as under floor areas of pole style houses.
Perimeter sprinkler system can also be fitted.
The system efficiency can be substantially
increased when fitted during the construction
phase because larger poly tube can be used as
it can be concealed in the wall cavity and the
roof space.
If fitted during construction only a small amount of
copper tube is required where the sprinklers
project out through the roof sheeting which
reduces the installation cost and is very neat as
most of the pipe work is concealed.
1155 Hidden Valley Road Parkerville WA 6081 I Telephone: 0428 500 295 I Email: [email protected]
Web: www.smallfarmservices.net.au
Small Farm Services
Benefits include:
Maximum water efficiency
Hidden Pipes and fittings
Remote control, with confirmation
text messages
No extra costs after build!
Activate your sprinkler system
by Mobile phone! 3G compatibleSPR IN NO KI LT EN RE SV YE SR TP E MER SIF
Install a
sprinkler system
while you build
or to your
existing home
Protect your home against fire
1155 Hidden Valley Road Parkerville WA 6081 I Telephone: 0428 500 295 I Email: [email protected]
Web: www.smallfarmservices.net.au
Small Farm Services
SPR IN NO KI LT EN RE SV YE SR TP E MER SIF
Multi-Attempt Automatic
Smart Switch
DESCRIPTION
SFS01-V2
If the engine has not fired by the end of first attempt, the starter is turned off for a resting period. The sequence will then repeat up to a maximum number of start attempts. Following a successful start, sensed when the oil pressure switch changes its state, the start relay is de-energized and latched out to prevent re-engagement of the starter with the engine running.
The Model SFS01-V2 is a Multi-attempt Automatic Engine Smart Switch designed to automatically [remotely] or manually start and stop the engine. It will indicate the operational status and fault conditions, automatically shut down the engine and indicate the start engine failure by a flashing “ST. FAIL” LED as well as informing operator via SMS. Other functions and possible engine fault conditions are also visually shown via a set of LEDs located on the module.The SFS01-V2 is designed to receive start/stop commands from a specially coded SMS or via direct call from a control server (CS) phone number(s). It is capable of storing up to 10 CS numbers (index 0~9) giving you and your colleagues an equal opportunity to control your engine from any place on earth where mobile network is available. You won't be charged for a call from CS phone number because the module will hang up incoming call
START and RUN Sequence
Relay outputs are provided for:• Fuel Solenoid Output • Starter Motor OutputThe relays supply positive plant supply out.
Inputs are available for:• • Wired Remote Start [wire 1]• Battery –Ve [wire GR/Y]• Battery +Ve [wire 6] • W. Pressure switch [wire 4]
Low Oil Pressure [wire 3]
Lower PCB (green): engine controllerWarning lights [LEDs] provided to indicate the following: • • E. STOP LED [Active state of emergency stop switch and S/D]• LOW OIL LED [Low oil pressure alarm and S/D] • HET/GL LED [High engine temperature and S/D]/[Glow plug
energized]• SPEED LED [Over/under engine speed failure and S/D]• ON LOAD LED [Generator is on load]
Upper PCB (blue): 3G/GSM controller• Green LED (SRV): lit during handling commands / messaging.Red LED (ACT): flashing every second during network initialization
thand flashing 2 times every 5 second after successful network initialization
ST. FAIL LED [Unsuccessful start after multiple attempts and S/D]
Engine controller specificationDC Supply: 12VdcMax. Standby current: ~10mA @ 12 VNumber of attempts: 5Crank durations: 2-3-3-4-5 secPause between each attempt: 20 secHold-off timer* set for: 7 secStarter relay output: 10A maxFuel solenoid output 10A maxOperating Temperature Range: -20 to +55°C.Humidity: Less Than 80% RH
3G/GSM controller specificationDC Supply: 12VdcMax. standby current:~150mA / Average 50mAReceiver/transmitter: Integrated into SFS01-3G module.Working Frequencies: Dual-Band UMTS/HSDPA850/1900MHz Quad-Band GSM/GPRS/EDGE 850/900/1800/1900MHzSIM Card: Standard size SIM (3V & 1.8V)SIM card must be activated and inserted by a user into de-energised module before powering up the unit.
Important features
•
•
•
•
•
•
•
•
3G and GSM compatible
Can be operated by text or voice call
Can be turned ON and OFF repeatedly as required
Comes pre-wired with 5m harness
SFS01-V2 Module monitors the engine starting battery condition and reports any faults automatically
SFS01-V2 Module monitors engine oil pressure and water pump pressure and reports status automatically
Custom built units for special applications available
Operates completely independent of any scheme power supply and has inbuilt battery back up to maintain communication.
Custom built units can be produced for many special applications e.g. stock watering, water transfer, dewatering, frost control and many more so if you have a particular application email your
requirements or phone to discuss.