52
Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 6 Protect The Complete Elevator System From Water/Dust & Corrosion! When determining what requires protection from moisture, dust and corrosion, make sure all parts of the elevator are covered. Whether it’s a passenger or freight, there are many areas of the elevator that require moisture, dust and corrosion protection. CJA offers the following for your moisture, dust and corrosion protection needs. Machine Room • Elevator Control Systems - For Any Speed, Type or Elevator Application • Elevator Motors • Communication Stations • Machine Room Lighting • Brake Limit Switches Manual Reset Top and Bottom of Hoistway • Final, Normal & Slow Down Switches • Access Over Travel Limit Switches Inside Elevator • Main & Auxiliary Car Stations For both Passenger and Freight Applications • Car Position Indicators - Digital/Multilight • Traveling Lanterns - Standard/Vandal Proof • Security Systems • Communication Stations • Security Cameras • Cab Lighting Elevator Pit/Bottom of Hoistway • Final, Normal & Slow Down Switches • Pit Switches • Pit Worklight and GFCI Receptacle Hoistway Equipment • Car Top Inspection Station • Accu-Track Selector System • Car Bottom Worklight & Receptacle • Retiring Cam • Cab Ventilation Fan • Door Interlocks Elevator Entrance/Hallway • Door Interlocks • Hall Stations • Digital Position Indicators • Hall Lanterns • Access Switch Stations • Security Systems • Security Cameras If you don’t see what you need listed here please call us at 800-252-1910!

Protect The Complete Elevator System From … The Complete Elevator System From Water/Dust &Corrosion! When determining what requires protection from moisture, dust and ... NEMA 4X

  • Upload
    vomien

  • View
    223

  • Download
    0

Embed Size (px)

Citation preview

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 54676

PPrrootteecctt TThhee CCoommpplleetteeEElleevvaattoorr SSyysstteemm FFrroommWWaatteerr//DDuusstt && CCoorrrroossiioonn!!

When determining what requires protection from moisture, dust andcorrosion, make sure all parts of the elevator are covered.

Whether it’s a passenger or freight, there are many areas of the elevator thatrequire moisture, dust and corrosion protection.

CJA offers the following for your moisture, dust and corrosion protectionneeds.

Machine Room• Elevator Control Systems - For Any Speed, Type or Elevator Application

• Elevator Motors• Communication Stations • Machine Room Lighting

• Brake Limit SwitchesManual Reset

Top and Bottom of Hoistway• Final, Normal & Slow Down Switches

• Access Over Travel Limit Switches

Inside Elevator• Main & Auxiliary Car Stations

• For both Passenger and Freight Applications • Car Position Indicators - Digital/Multilight• Traveling Lanterns - Standard/Vandal Proof

• Security Systems • Communication Stations

• Security Cameras • Cab Lighting

Elevator Pit/Bottom of Hoistway• Final, Normal & Slow Down Switches

• Pit Switches• Pit Worklight and GFCI Receptacle

Hoistway Equipment• Car Top Inspection Station

• Accu-Track Selector System • Car Bottom Worklight & Receptacle

• Retiring Cam• Cab Ventilation Fan

• Door Interlocks

Elevator Entrance/Hallway• Door Interlocks

• Hall Stations• Digital Position Indicators

• Hall Lanterns• Access Switch Stations

• Security Systems• Security Cameras

If you don’t see what you need listed here please call us at 800-252-1910!

Buildings all over the world needelevator equipment designed toprevent moisture, corrosion anddust from destroying them.

CJAequipment can be found onelevators everywhere, from thelargest cities in the world, to thesmallest towns in the USA.

Some buildings, locations andindustries request our equipmentbecause of its dependability andease of installation.

CJA equipment is used almostexclusively in many industries. The following are just a few ofthem.

• Power Generating Plants• Paper Processing Facilities• Housing Authorities• Transit Authorities • Sugar Mills• Parking Garages• Factories• Passenger & Freight Elevators• Exposed Hoistways & Elevators• Tower Lifts• Breweries • Universities• Shipboard Elevators• Baseball Ballparks

Niagara Falls Access ProjectProject Scope: Fixtures, Switches

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 7

Elevator Systems Everywhere!

FFiixxttuurree PPaacckkaaggeess -- NNEEMMAA 44XX && 44//1122

Transit: MBTA, SEPTA,MARTA, BARTProject Scope: Fixtures, Switches,

Selector Systems

Midwest GenerationPower Generating Plants

Project Scope:Fixtures, Selector

Safeco Field - Baseball ParksProject Scope: Fixtures

Breweries - Anheuser BuschProject Scope: Fixtures, Switches,

Interlocks, Selector

Parking GaragesProject Scope: Fixtures, Controllers,

Selector, Switches

Any Elevator within 5 Milesfrom any ocean; Condos etc.

Project Scope: Everything Possible

Passenger ElevatorMilwaukee Art Museum

Project Scope: Fixtures, Switches

Freight ElevatorGeorgia Aquarium

Project Scope: Fixtures, Switches

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 54678

Okay we’ll say it! TheNEMA 4X - 316 Fixture Linewas developed to combat thetransit urinators of America!

We figured that there weretwo options when dealingwith this problem. The firstinvolved installing urinals inthe elevator and the secondwas manufacturing ouralready great NEMA4XFixtures with Type 316Stainless Pushbuttons,Enclosures and Faceplates

In addition to being specifiedfor every major transit systemin North America, the NEMA4X - 316 Fixture line by

C.J. Anderson is also ideal forcoast environments whereelevators are located withinfive miles from any body ofsalt water.

Salt in the air will corrodeeven type 304 stainless steel ifit is not cleaned regularly.

Features • Seamless enclosure• construction - Type 316• 11 gauge stainless steel• covers plates brush finish• Type 316• Stainless steel buttons - 316• Tamperproof screws - 316• Neoprene gaskets

LocationsLocations where NEMA 4X,Type 316 is highlyrecommended include: • The California Coast• Gulf Coast• East Coast• Florida• Shipboard Elevators• Exposed Elevators

CCJJAA NNEEMMAA 44XX -- 331166FFiixxttuurree DDeessiiggnn aannddCCoonnssttrruuccttiioonn iissUUnnmmaattcchhaabbllee

NNNNEEEEMMMMAAAA 4444XXXXTTTTYYYYPPPPEEEE 333311116666CJACJA FixturFixturesesmanufacturmanufactured fored forindoor or outdoorindoor or outdooruse to pruse to provide aovide adegrdegree ofee ofprprotection againstotection againstextrextreme coreme corrrosionosionusing 316 Susing 316 Stainlesstainlesssteel forsteel forpushbuttons,pushbuttons,faceplates,faceplates,enclosurenclosures,es,windblown dust,windblown dust,rain, splashingrain, splashingwaterwater, and to be, and to beundamaged by theundamaged by theformation of ice onformation of ice onthe enclosurthe enclosure. e.

The bestThe bestdefensedefenseagainst urineagainst urineand saltand saltwater!water!

Since we’re the experts when it comes to water andexplosion proof elevator equipment, we figured we’dneed to know quite a bit about how our equipment isaffected by water and other corrosive gases andmaterials. The bottom line is that stainless is not all thesame.

Both photographs show stainless steel from the 300Series which has more chromium in it than the 400Series does. Both metal samples were exposed to theelements five miles from the southern coast of SouthCarolina for an extended period of time.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 9

Stainless Steel Is Not Created Equal

EExxttrreemmee CCoorrrroossiioonn CCoonnttrrooll -- 331166 SSttaaiinnlleessss SStteeeell FFiixxttuurreess

TYPE 304 - 1941 TO 1981

Keep in mind how long this piece was exposed to theenvironment, over 40 years. Note that in extremelycorrosive environments your equipment may performbetter or worse.

The standard for our NEMA 4X Fixture Line, Type304 Provides excellent protection against corrosion.

TYPE 316 - 1941 TO 1981

This piece was also exposed to the environment for 40years.

The standard for our Coastal and Transit SeriesFixtures, Type 316 provides the ultimate in corrosioncontrol. Because of its chemical make up it will outlast304 and provide the most protection in areas wherecorrosion is a problem.

FAST FACTSWhether it’s Type 304 or 316 Stainless Steel, it’s happiest when kept clean with a soft damp cloth and a mild soapysolution.

Stainless steel has a unique feature: It is self healing. Due to the alloying elements in the stainless steel, a thintransparent “passive layer” is formed on the surface. This is one of the reasons why we apply a brush finish to allfixtures.

Even if the stainless steel surface is scratched or damaged, this passive layer, which is only a few atoms thick,instantaneously reforms under the influence of the oxygen in the air. This explains why stainless steel does notrequire any coating or corrosion protection to remain bright and shiny after decades of use.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546710

The major distinction betweenNEMA4 and NEMA4X is inthe enclosure. The NEMA4X enclosure is manufacturedof type 304 stainless steel toprotect against corrosiveagents. The NEMA4XFixture line meets NEMA 4& 12 water & dust resistantrequirements as well. Theface plates and buttons arestainless steel and of the samevandal proof construction. NEMA4X is recommendedwherever corrosion is aserious problem, such as saltwater environments.

Custom engraving isavailable, including arrows,words, pictograph, logos andinstructions.

This heavy duty constructioncoupled with a buttondesigned to absorb abuse alsomakes these fixtures the mostvandal proof on the market.

Features • Seamless enclosureconstruction

• 11 gauge stainless steelcovers plates• #4 Brush Finish • Stainless steel buttons• Tamperproof screws • Neoprene gaskets • Custom engraving• Recessed braille tags• Mounting means external toequipment cavity

• Vandal proof construction

Typical Applications• Breweries• Pharmaceutical Plants• Factories• Meat Processing Plants• Locations that have highvandalism

• Tower Elevators• Sidewalk Lifts• Dusty/Dirty Environments• Housing Authorities• Transit Authorities• Parking Garages

LocationsLocations where NEMA 4Xis highly recommendedinclude: • The California Coast• Gulf Coast• East Coast• Florida• Shipboard Elevators• Exposed Elevators

NEMA 4X & 4/12 CJA Fixtures manufactured forindoor or outdoor use to provide adegree of protection againstcorrosion, windblown dust, rain,splashing water, and to beundamaged by the formation ofice on the enclosure. They arenot intended to provideprotection against conditionssuch as internal condensationor icing. However we canprovide heating elements anddrains to prevent both fromoccurring.

Project: Niagara Falls

CCuussttoomm IIss OOuurr SSttaannddaarrdd

FAST FACTS: LESS THAN ONE PERCENTActually, more like .875% of our annual sales account for replacement fixture parts sales. What this means is thatCJA NEMA 4X, 4/12 Fixtures will last a long time. Ask ANY other fixture company how much they sell inreplacement parts and see if they share that information with you? I betcha nickel (a quote from my Grandma) thatit’s a heck of a lot more than 1 percent!

FFiixxttuurree FFeeaattuurreess -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 CJA 1910• www.cjanderson.com • Fax: 1 708 867 5467 11

NEMA 4,12 & 4X Gasketed, VandalProof Button, Stainless Steel Type 304

Solid Lucite Illumination Jewel

Solid Construction Meansa Longer Lasting Product

NEMA 4X Type 304 - 316 SeamlessEnclosures

Gasketed Key Switches

Neoprene Gasketed Recessed Braille Tags Prevents ThemFrom Being Pryed Up & Out

Vandal Proof ConstructionLenses, Pushbuttons

Mounting Means External To TheEnclosure

Custom Engraving, Logos, Graphics, Symbols and Other Languages too!

Clear Coated Printed Circuit BoardsFor Real Extreme Locations

Surface Mount

Flush Mount

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546712

Features • Seamless enclosure• construction• 11 gauge stainless steel• cover plates• #4 Brush Finish • Stainless steel buttons• Tamperproof screws • Neoprene gaskets • Custom engraving• Recessed braille tags• Mounting means external to• equipment cavity• Vandal proof construction

Typical Applications• Breweries• Pharmaceutical Plants• Factories• Meat Processing Plants• Locations that have highvandalism

• Tower Elevators• Sidewalk Lifts• Dusty/Dirty Environments• Housing Authorities• Transit Authorities• Parking Garages

LocationsLocations where NEMA 4Xis highly recommendedinclude: • The California Coast• Gulf Coast• East Coast• Florida• Shipboard Elevators• Exposed Elevators

Need a fixture quote? Call ustoday at 1-800-252-1910, goonline, www.cjanderson.comor fill out the form in the backof this catalog and fax to 708-867-5467!

NEMA 4X & 4/12 Project: Georgia Aquarium

Freight ElevatorWWee EEvveenn HHaavvee FFiixxttuurreess IInnAAqquuaarriiuummss!!

Position IndicatorsDigital or Multilight

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 13

A La Carte or Custom, It’s Up To You!

HHaallll SSttaattiioonn OOppttiioonnss -- NNEEMMAA 44XX && 44//1122

Communication OptionsIntercom System

Recessed Stainless Steel Braille TagsPrevents Prying them off panel

Complete Customization with layout,features, etc.

Custom Engraving & Color Filling Lockable Service CabinetsBuilt with features that that you request

Key Switches For Standard ElevatorFeatures or Floor Lockout

ADA Telephones Emergency Lighting

Fire Service For 1996, 2000, 2004,2009 or for your area FEOK1, 2642,

3502, SC1000 Key Switches

Pushbuttons, any configuration, layoutthat you’d like.

Custom Logo, Text Engraving

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546714

Custom FixturesWe can do almost anythingwhen it comes to signalfixtures. If you’re an architector consultant and wantsomething special and it needsto be water or corrosionresistant then you’ve come tothe right place.

If you’re contemplating acustom design and wantpricing, simply make ageneral sketch of the fixtureyou’re looking for. This canbe on a napkin, standard sheetof paper or on large paperformat. Once you’ve got thesketch completed fax it to708-867-5467, attentionFixture Team.

After we review your designwe’ll fax you a quotation. Ifthe project is a go, we willcreate a set of drawings forapproval by you. Once thefinal design is completed andapproved we will beginmanufacturing.

Our manufacturingcapabilities allow us totalcontrol. CNC MillingMachines, Engravers, PlasmaCutters and WaterjetMachines allow us to takeyour design concept and turnit into reality. You tell us whatyou want and we’ll make it.

SENDUSYOURDESIGN

Grab your favoritedoodling device andyour elevator fieldpocket book and go to town!

NEMA 4X & 4/12Pedestal Hall Call Station

with FEOK1 Phase I Switch

ITEM: CJA-EFPN - Elevator Field Notebook - FREE!Order Yours Today!

Skinny car stations, customenclosure and faceplate sizes, youname it we can do it. Our VXMPB contact block has some greatfeatures including it’s compact sizeand voltage rating 6-240 VAC orDC.

Pictured above: The famous VX-I& VX Stainless Steel, NEMA 4/4X& 12 Vandal Proof pushbuttonswith retaining clips.

Pictured above: MPB ContactBlock with Lamp and PushbuttonActuator, very compact, spacesaving, multi-voltage design.allows a 1.75” button centerdistance!

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 15

Custom Is Our Standard

CCuussttoomm FFiixxttuurreess -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546716

NEMA 4X Extended ADAHall Stations are intended todrop existing hall buttonsdown to acceptable ADA(Americans with DisabilitiesAct) height requirementswhile covering up yourprevious hall station cutout.These models are water, dustand corrosion resistant.

While our NEMA4X Modelcomes in a variety ofconfigurations, the size can bechanged to meet yourrequirements. Just call us withyour size requirements.

Each stainless steelpushbutton rests on thecoverplate, which absorbs anyexcessive force. Each also hasa mechanical contact blockwith LED illumination. Eachcontact block has twonormally opened contacts.Sealed with gasketing for yourmoisture protection needs, thisfixture is ideal for anyapplication.

PPPPeeeerrrrffffeeeecccctttt ffffoooorrrr CCCCoooonnnnddddoooossss,,,,PPPPoooooooollll SSSSiiiiddddeeee EEEElllleeeevvvvaaaattttoooorrrrssssaaaannnndddd TTTTrrrraaaannnnssssiiiitttt SSSSttttaaaattttiiiioooonnnnssss

NEMA 4X & 4/12ADA Hall Station withEngraved Pictograph

CJA Standard ADA Hall Stations are asfollows: 23.5” Tall x 6.5” Wide and extend.875” off of the wall. Other custom sizes

are available depending on yourapplication. Please call for additional

information.

17. 5

”Ce

nter

line

of B

utto

ns to

top

ofco

verp

late.

42”

FIRE SERVICE

Before - Old Hall Station To High From Finished Floor

After - CJA Extended NEMA 4X Hall station

FIRE SERVICE

The old hall station was installed before the ADA (Americans withDisabilities Act) was passed. For a quick and easy solution to new ADAhall pushbutton station requirements, order an extended ADA Hall stationfrom CJA.

By removing the existing hall station and using the old cutout in the wallas a cavity for the backing of the fire service or access key switch, youcan reuse your wiring and mount a new ADA station quickly and easily.

50”

Doe

s NO

Tm

eet A

DA

heig

ht R

equi

rem

ents

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 17

EExxtteennddeedd AADDAA NNEEMMAA 44XX HHaallll SSttaattiioonnss

Terminal Hall StationsFH3101-ADA Call Button OnlyFH3111-ADA w/Fire Service Key Switch

Phase I - 702HFH3112-ADA w/Access Key Switch:700M

3 PositionFH3113-ADA w/Fire Serv. & Access Key

Sw. - 702H & 700M

Intermediate Hall StationsFH3104-ADA Up Button & Down ButtonFH3141-ADA w/Fire Service Key Switch

Phase I - 702HFH3142-ADA w/Access Key Switch: 700M

3 PositionFH3143-ADA w/Fire Serv. & Access Key Sw.-

702H & 700M

CJA Standard ADA Hall Stations are as follows: 23.5”Tall x 6.5” Wide and extend .875” off of the wall. Othercustom sizes are available depending on yourapplication. Please call for additional information.

Solid, Long Lasting & Sealed!

FH3112-ADACall Button

& Access KeySwitch

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546718

Features • Seamless enclosure• construction• 11 gauge stainless steel • covers plates• #4 Brush Finish • Stainless steel buttons• Tamperproof screws • Neoprene gaskets • Custom engraving• Recessed braille tags• Mounting means external to • equipment cavity• Vandal proof construction

Typical Applications• Breweries• Pharmaceutical Plants• Factories• Meat Processing Plants• Locations that have high• vandalism• Tower Elevators• Sidewalk Lifts• Dusty/Dirty Environments• Housing Authorities• Transit Authorities• Parking Garages

LocationsLocations where NEMA 4Xis highly recommendedinclude: • The California Coast• Gulf Coast• East Coast• Florida• Shipboard Elevators• Exposed Elevators

Need a fixture quote? Call ustoday at 1-800-252-1910, goonline, www.cjanderson.comor fill out the form in the backof this catalog an fax to 708-867-5467!

IInndduussttrriiaall tthhaatt ddooeessnn’’tt““LLOOOOKK”” tthhee ppaarrtt!!

Position IndicatorsDigital or Multilight

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 19

A La Carte or Custom, It’s Up To You!

HHaallll SSttaattiioonn OOppttiioonnss -- NNEEMMAA 44XX && 44//1122

Communication OptionsIntercom System

Recessed Stainless Steel Braille TagsPrevents Prying them off panel

Complete Customization with layout,features, etc.

Custom Engraving & Color Filling Lockable Service CabinetsBuilt with features that you request

Key Switches For Standard ElevatorFeatures or Floor Lockout

ADA Telephones Emergency Lighting

Fire Service For 1996, 2000, 2004,2009 or for your area FEOK1, 2642,

3502, SC1000 Key Switches

Pushbuttons, any configuration, layoutthat you’d like.

Custom Logo, Text Engraving

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546720

Hall fixtures are made for aspecific application from asingle button terminal stationto a multi-button call/sendoperation. Station size,number of buttons, lenses andkey switches are not arestraint.

NEMA4X, 4/12 stationsinclude stainless steel coverplates, enclosures and buttons.Custom engraving isavailable, including arrows,words, pictograph, logos andinstructions.

These fixtures aremanufactured for indoor oroutdoor use to provide adegree of protection againstcorrosion, windblown dust,rain, splashing water, and tobe undamaged by theformation of ice on theenclosure. They are notintended to provide protectionagainst conditions such asinternal condensation or icing.However we can provideheating elements and drains toprevent both from occurring.

TTeerrmmiinnaall HHaallllSSttaattiioonnss BBoottttoomm &&TToopp FFlloooorrssTThhee eenndd ooff tthhee lliinnee,, ssoo ttoo ssppeeaakk..

NNEEMMAA 44XX && 44//1122Surface Mount Terminal Hall Station

Pictured Above: Custom Terminal Hall Stationwith Engraving, 1996 FS Code, Lock Out

Switch and Call Button.

Pictured Above: NEMA 4X Surface MountFire Service Station For Alternate Floor

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 21

Terminal StationUsed on elevators that have full automaticoperation or selective collective. The hall callpushbutton will illuminate until the elevator hasstopped at the floor.

MODELS AVAILABLEFH3101 Call Button OnlyFH3111 w/Fire Service Key Sw.

(specify key switch number)FH3112 w/Access Key SwitchFH3113 w/Fire Serv. & AccessFH3114 w/Door Open & Door CloseFH3115 w/Door Open & Close & Fire ServiceFH3116 w/Door Open & Close & AccessFH3117 w/Door Open & Close, FS & AccessFH3118 w/Door Open, Close, Stop & Fire Sw.FH3119 w/Door Open, Close, Stop & AccessFH3120 w/Door Open, Close, Stop, Fire, Acc.

Terminal Station w/In Use LensUsed on elevators that have single automaticoperation, meaning that once a call has beenplaced, the elevator will not pick up a passengeruntil the person who is inside the elevator hasarrived at his floor. The In-Use indicator willilluminate until the elevator is not movinganymore.

MODELS AVAILABLEFH3102 Call Button & In Use LensFH3121 w/Fire Service Key Switch

(specify key switch number)FH3122 w/Access Key SwitchFH3123 w/Fire Serv. & Access Key Sw.FH3124 w/Door Open & Door CloseFH3125 w/Door Open & Close & Fire ServiceFH3126 w/Door Open & Close & AccessFH3127 w/Door Open & Close, FS & AccessFH3128 w/Door Open, Close, Stop & Fire Sw.FH3129 w/Door Open, Close, Stop & AccessFH3130 w/Door Open, Close, Stop, Fire, Acc.Each station includes Call Button and itemslisted.

Terminal Hall Stations withDigital Position IndicatorsHigh-tech digital position indicators can beadded. Our 3 wire serial link position indicatorsmake wiring a breeze. Elevators are less likely tobe vandalized when people can actually seewhere the elevator is. This upgrade will offeryour client the look and feel of a new elevatorwithout the cost of upgrading the entire elevatorsystem.

MODELS AVAILABLEFH3103 Call Button & Digital P.I.FH3131 w/Fire Service Key Sw. PHI

(specify key switch number)FH3132 w/Access Key SwitchFH3133 w/Fire Serv. & Access Key Sw.FH3134 w/Door Open & Door CloseFH3135 w/Door Open & Close & Fire ServiceFH3136 w/Door Open & Close & AccessFH3137 w/Door Open & Close, FS & AccessFH3138 w/Door Open, Close, Stop & Fire Sw.FH3139 w/Door Open, Close, Stop & AccessFH3140 w/Door Open, Close, Stop, Fire, Acc.Each station includes Call Button and itemslisted.

Note that we will send you a drawing of yourfixture for approval before we manufacture it.

Terminal Hall Stations

Pictured Above: FlushMount, Custom HallStation with MedicalEmergency Switch

Pictured Above:Flush Mount: FH3111

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546722

Hall fixtures are made for aspecific application from asingle button terminal stationto a multi-button call/sendoperation. Station size,number of buttons, lenses andkey switches are not arestraint.

NEMA4X, 4/12 stationsinclude stainless steel coverplates, enclosures and buttons.Custom engraving isavailable, including arrows,words, pictograph, logos andinstructions.

These fixtures aremanufactured for indoor oroutdoor use to provide adegree of protection againstcorrosion, windblown dust,rain, splashing water, and tobe undamaged by theformation of ice on theenclosure. They are notintended to provide protectionagainst conditions such asinternal condensation or icing.However we can provideheating elements and drains toprevent both from occurring.

IInntteerrmmeeddiiaattee HHaallll SSttaattiioonnssEEvveerryywwhheerree iinn bbeettwweeeenn..

NNEEMMAA 44XX && 44//1122Flush Mount Custom Hall Station with NY 2642

Key Switch & Four Character P.I.

Pictured Above: Custom Intermediate HallStation mounted in small enclosure

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 23

Intermediate Hall StationsFound on typical passenger elevators at themiddle floors. Keep in mind that we offer manydifferent sizes and options when it comes tomanufacturing. The models and photos shownon this page are simply our attempt to providesome idea of our standard product.

MODELS AVAILABLEFH3104 Up Button & Down ButtonFH3141 w/Fire Service Key Sw. :PHI

(specify key switch number)FH3142 w/Access Key Switch: 700MFH3143 w/Fire Serv. & Access Key Sw.FH3144 w/Door Open & Door CloseFH3145 w/Door Open & Close & Fire ServiceFH3146 w/Door Open & Close & AccessFH3147 w/Door Open & Close, FS & AccessFH3148 w/Door Open, Close, Stop & Fire Sw.FH3149 w/Door Open, Close, Stop & AccessFH3150 w/Door Open, Close, Stop, Fire, Acc..Each station includes Call Button and itemslisted.

Intermediate Hall Stations withDigital Position IndicatorsIf you’ve got a moisture, dust or corrosionproblem and would like to add high-tech digitalposition indicators, now is the perfect time to doso. Our 3 wire serial link position indicatorsmake wiring a breeze. Elevators are less likely tobe vandalized when people can actually seewhere the elevator is.

MODELS AVAILABLEFH3106 Up & Down Button & Digital P.I.FH3161 w/Fire Service Key Sw. 702H: PHIFH3162 w/Access Key Switch: 700MFH3163 w/Fire Serv. & Access Key Sw.FH3164 w/Door Open & Door CloseFH3165 w/Door Open & Close & Fire ServiceFH3166 w/Door Open & Close & AccessFH3167 w/Door Open & Close, FS & AccessFH3168 w/Door Open, Close, Stop & Fire Sw.FH3169 w/Door Open, Close, Stop & AccessFH3170 w/Door Open, Close, Stop, Fire, Acc.Each station includes Call Button and itemslisted.

Power Freight Door ApplicationsIdeal for any freight elevator with poweroperated doors. Heavy duty stainless steelpushbuttons and mechanical contact blocks willprovide dependable service.

These fixtures interface with any new or existingpower operated freight door. Our stackablecontact block allows the addition of a variety ofcontact configurations at any time.

MODELS AVAILABLEWith Call Button - Terminal FloorsFH3114 w/Door Open & Door CloseFH3115 w/Door Open & Close & Fire ServiceFH3116 w/Door Open & Close & AccessFH3117 w/Door Open & Close, FS & AccessFH3118 w/Door Open, Close, Stop & Fire Sw.

With Up,Down Button-Intermediate FloorsFH3144 w/Door Open & Door CloseFH3145 w/Door Open & Close & Fire ServiceFH3146 w/Door Open & Close & AccessFH3147 w/Door Open & Close, FS & Access

Note that we will send you a drawing of yourfixture for approval before we manufacture it.

Intermediate Hall Stations

Pictured Above: Custom Intermediate HallStation With Intercom, Run/Stop Toggle and

E-Stop Button

Pictured Above:Flush Mount: FH3104Pictured Above: Freight Elevator Hall Station

ITEM: FH3164

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546724

In addition to being built intoa car or hall station, positionindicators can also be standalone units. Monitor anynumber of elevators from onelocation at a time.

These position indicators canbe furnished in a variety ofcustom sizes and layouts tomeet your project and cutoutrequirements. For example,vertical mount, longhorizontal mount, oversizeface plates, etc. We can supplydigital position indicators in avariety of wiring formats: oneline per floor, serial link orbinary.

NEMA4X & 4/12-Water/Corrosion Resistant& Dust Tight FeaturesStainless Steel Enclosures andFaceplates, GasketedCoverplate and Lens makeswater entry impossible.

DDiiggiittaall PPoossiittiioonnIInnddiiccaattoorrssSSttaanndd AAlloonnee,, HHaallll,, CCaarr oorr LLaanntteerrnn

NNEEMMAA 44XX && 44//1122Flush mount digital position

indicator with combo directionallantern and stand alone digital p.i.

NEMA 4X & 4/12Custom sealed surface mountlobby status station with LED read outs.

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 25

Digital position indicators are great for lettingeveryone know where the elevator is andthey’ve been known to help in minimizingvandalism to the elevator. I’m not sure if it’sbecause it occupies people or if they don’t getaggravated because they can see the elevator isactually moving.

Our digital position indicators come a variety ofways to connect to your elevator controller.While we have standard sizes we also canprovide custom faceplate and enclosure sizes tofit existing holes in the wall.

You’ll need to specify the following informationwhen ordering so that we can ensure that theposition indicator interfaces correctly with yourelevator controller.

MODELS AVAILABLEColor Of Digital Position Indicator

- Red- Blue

Number of Floors- 1-15 Floors- 17-31 Floors- Serial Link - Micro Comm

Floor Markings__________________________________________________________________________________________________________________

Signal Voltage- Positive 6-20VDC, 6-24VAC- Positive 24-48VDC, 24-48VAC- 110/120VAC- Positive 125VDC- Negative 6-20VDC- Negative 24-48VDC- Negative 125VDC- Serial Link - Micro Comm

Signal Format- Single Line/1 Wire Per Floor- Binary- Units & Tens- Gray Code- Inverted Binary- Special (please call)- Serial Link - Micro Comm

Digital Position Indicators

Pictured Above: Also available in car stations and hall stations

Segemented P.I.

Dot Matrix P.I.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546726

In addition to being built intoa car or hall station, multilightposition indicators can also bestand alone units. Monitor anynumber of elevators from onelocation at a time.

These position indicators canbe furnished in a variety ofcustom sizes and layouts tomeet your project and cutoutrequirements. For example,vertical mount, longhorizontal mount, oversizeface plates, etc.

NEMA4X & 4/12-Water/Corrosion Resistant& Dust Tight FeaturesStainless Steel Enclosures andFaceplates, GasketedCoverplate and Lens makeswater entry impossible.

MMuullttii LLiigghhtt PPoossiittiioonnIInnddiiccaattoorrss

CP 1 1/16” Round Lens - Flush Mount Design

Stainless Steel Back Box Flush Mount

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 27

Our standard NEMA 4X Multilight positionindicators are not standard at all. Choose fromour Lucite white gasketed lenses or our seethrough and filled slotted vandal proof lens.These units are gasketed and manufactured withstandard incandescent type bulbs in the voltageyou need. LED illumination is available to cutdown on re-lamping. LED works best with thesmaller 3/8” filled lenses than with our CP whitelens.

Whether it’s vertical or horizontal lens alignmentwe can manufacture your hall/car multilightposition indicator in either vandal proof orstandard models.

Have a unique floor marking, like 100? We canengrave anything your customer needs.

MODELS AVAILABLENEMA4X& 4/12 -Water/CorrosionResistant, Dust TightIn addition to standard or vandal proof lenses weoffer our NEMA 4X model in a surfacemounting unit, which means no cutout required.

Information required to order: Floor markings,lamp voltage and surface or flush mount.

Lens Lighted Indicators

CP 1 1/16” Round Lens with NeopreneCork Gasket - Shown Actual Size

3/8” Vandal Proof Surface Mount P.I. DesignWith Engraved Floor Markings

Flush Mount P.I Design with Slotted Vandal Proof Lens& Engraved Floor Markings

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546728

Arequirement by theAmericans with DisabilitiesAct, each of our hall and cardirectional lanterns isequipped with a 2.5” wideilluminating arrow. Alsomounted inside is ourdirectional chime that strokeseither once or twicedepending on the direction ofthe elevator.

These can be mountedvertically or horizontallyabove the elevator doorentrance or just to the side ofit. These units indicate thedirection the elevator istraveling and provide twoseparate audible tones, singleand double, for the sightimpaired.

Vandal proof models havedrilled and filled holes thatpermit illumination whilepreventing vandals frombreaking plastic lenses. Eacharrow is illuminated usingincandescent lamps.

Enclosure and cover plate arefully gasketed and ready forthe elements.

DDiirreeccttiioonnaall LLaanntteerrnnssTTrraavveelliinngg && HHaallll

NEMA 4X Intermediate Hall Lantern,Horizontal Plastic Lens, Flush Mount

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 29

Each directional lantern comes ready to install.Multivoltage directional chime, light bulbs,cover plate and enclosure are standard for eachunit. If you have a custom size that you need, letus know and we can fabricate it accordingly.

MODELS AVAILABLE716-114-4X Terminal Lantern

One ArrowChoose Features Below

716-115-4X Intermediate LanternTwo Arrows Choose Features Below

Face Plate Options- Vertical Mount- Horizontal Mount

Lens Type- Vandal Proof Lens- White Plastic Lens

Mounting Option- Flush Mount Design- Surface Mount Design

Voltage For Lamps/Chime- 24V- 48V- 110/120V

Ordering Information

NEMA 4X Car or Hall IntermediateLantern, Vertical Vandal Proof Lens,

Flush Mount

Don’t forget we can provide combination digital position indicators and hall lanterns

Vandalproof Lenses are filled with a specialepoxy type material and are flush with the

cover plates.

NEMA 4X Terminal Car/Hall Lantern withcustom 3” Round Plastic Lens - Flush Mount

NEMA 4X Intermediate Car/Hall Lantern withcustom 2.5” Round Plastic Lens - Flush Mount

NEMA 4X CabinetsWe offer water, corrosion anddust tight cabinets for a varietyof applications. What you putin them is up to you, electricalor non-electrical. Each heavyduty hinged door and handleassembly can take a beating.Cabinets are available withbraille markings and/orlocking handle and can havecustom engraving.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546730

CCoommmmuunniiccaattiioonn CCaabbiinneettssaanndd TThhee DDeevviicceess TThhaatt GGoo IInnssiiddee

Weather Resistant HR-70Telephone: ITEM: 716-207-4-S

ITEM: 716-204-4X Cabinet: 23” x 11” x 5.5” Hinged Right

ITEM: 716-202-4X Cabinet:10” x 6” x 3.875” Hinged Left

Handset TelephonesWe offer the toughest industrial typetelephones on the market. Reliablecommunication is now availableoutdoors where water, dust andweather conditions wreak havoc.

Meeting the same high standards asCJA’s severe and hazardousenvironment telephones, the HR70is ideal for wet, corrosive, noisy orrough use areas.

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 31

NEMA 4X CabinetsProduct Features• Stainless Steel Seamless NEMA 4X Enclosure• Engraved Cover Plate• Gasketed Coverplate• Rust and corrosion resistant stainless hardware

MODELS AVAILABLE716-202-4X Cabinet: 10 x 6 x 3.875 716-203-4X Cabinet: 16 x 11 x 3.875716-204-4X Cabinet: 23 x 11 x 5.5

Check Features Below- Hinged Right- Hinged Left

- Surface Mount- Flush Mount

- Twist “T” Handle- Lockable

Auto Dialing Telephone - NEMA 1Product Features• Stainless Steel Seamless Enclosure• Telephone Line Powered• Adjustable Volume & Microphone Setting• Perfect for Any NEMA 4X Cabinet

MODELS AVAILABLE737-201-S Auto Dialing Telephone

NOT NEMA4X but protected when installedin cabinet above

Sealed Handset TelephoneProduct Features• Membrane Keypad / Curly Handset Cord • Service temperature range: -40° to +140°F• Encapsulated circuit boards• Rust and corrosion resistant stainless hardware• Electret noise reducing microphone• Magnetic reed hook• Surge arrestor to prevent voltage spike damage• Hearing aid compatible• Electronic ringer for reliability• Modular parts for easy service

MODELS AVAILABLENEMA4 /12 Water/Dust Resistant 716-207-4-S HR70 - Telephone

Ordering Information

NEMA 1 - Standard AutodialingTelephone for any NEMA 4XCabinet.

VRT-1000 TELEPHONEPROGRAMMING GUIDE

1. From another phone, dial the number of theADA phone.

2. ADA phone will come on line after one ring.

3. When ADA phone comes on line, wait fiveseconds and enter security code 1,2,3,4,5,6.

4. Enter primary number to be called fromADA phone, followed by #0,0

5. You should hear two beeps.

6. Enter secondary number followed by #0,1

7. You should hear two beeps.

8. Enter *4 to start voice message recording.You have 10 seconds to record message.

Pushing any key stops the recording.

9. Enter ADA phone I.D. number followed by#2,0.

10. Hang up. Your ADA phone is now programmed.

TTEELLEEPPHHOONNEE MMUUSSTT BBEE CCOONNNNEECCTTEEDD

TTOO AA DDEEDDIICCAATTEEDDTTEELLEEPPHHOONNEE LLIINNEE!!

Auto Dialing PhonesOur ADAtelephone systemsare ideal for any environmentwhich is dusty, dirty or wheremoisture is present.Microphone and speaker areprotected against theoccasional contact with theseelements.

Our hands free telephoneallows for easy programming.Just plug a telephone line inand you’re all set to go. Nobattery backup or auxiliarypower is required.

Intercom StationsOur intercom systems areavailable in water/corrosionand dust tight models. Theycan be incorporated into anycar station and are ideal forharsh environments.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546732

IInntteerrccoomm SSyysstteemmss &&AADDAA TTeelleepphhoonneess

ITEM: 716-201-4X-SNEMA 4X Surface Mount ADATelephone

Intercom #1

Surface MountIntercom Station

2 Station Intercom Module

110VAC Power

Flush MountIntercom Station

Intercom #2

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 33

Auto Dialing TelephoneProduct Features• Stainless Steel Seamless NEMA 4X Enclosure• Telephone Line Powered• PCB circuit board protection• Rust and corrosion resistant stainless hardware• Adjustable Volume & Microphone Setting

MODELS AVAILABLE716-201-4X-F Auto Dialing Telephone -

Flush Mount716-201-4X-S Auto Dialing Telephone -

Surface Mount (shown)

Share 8 Phones on 1 LineThe LC-8 Allows 8 VRT-1000 emergencytelephones to share one outgoing line. This is ahuge costs savings as monthly line charges withtaxes can amount to a large part of a telephonebill each month.

This unit is NOT water/corrosion or dust tight.Please mount it in a location where it will beprotected from these elements.

MODELS AVAILABLE637-201-CON LC-8 Line Consolidator -

NEMA 1 Enclosure

Intercom StationsSimply connect each intercom to the intercommodule and plug the module into a 110 VACoutlet.

These are ideal for applications wherecommunication to the elevator is required. Forinstance, mount one in the elevator and one inthe machine room or security station. Thisallows for constant contact and requires nooutside phone line.

MODELS AVAILABLE716-206-4X Intercom System - Two

Intercom Stations and DLE Module

Check Features Below - Mounting OptionsIntercom 1

- Flush - Surface

Intercom 2- Flush - Surface

If a custom size is required please call us. Wecan manufacture an oversized cover plate tocover an existing hole with ease.

Ordering Information

ITEM: 637-201-CONLC-8 Line Consolidator

VRT-1000 TELEPHONEPROGRAMMING GUIDE

1. From another phone, dial the number ofthe ADA phone.

2. ADA phone will come on line after onering.

3. When ADA phone comes on line, wait fiveseconds and enter security code 1,2,3,4,5,6.

4. Enter primary number to be called fromADA phone, followed by #0,0

5. You should hear two beeps.

6. Enter secondary number followed by #0,1

7. You should hear two beeps.

8. Enter *4 to start voice message recording.You have 10 seconds to record message.

Pushing any key stops the recording.

9. Enter ADA phone I.D. number followedby #2,0.

10. Hang up. Your ADA phone is now programmed.

TTEELLEEPPHHOONNEE MMUUSSTT BBEE CCOONNNNEECCTTEEDD

TTOO AA DDEEDDIICCAATTEEDDTTEELLEEPPHHOONNEE LLIINNEE!!

Emergency LightingYou can include emergencylighting in your car station oradd it as a separate fixture tobring your elevator up to code.

If you don’t have a 6VDCalarm bell we recommend thatyou purchase one of each ofthe items shown to completeyour kit.

Each emergency light requiresa 110VAC power feed andoutputs 6VDC to power boththe alarm button lamp and6VDC alarm bell pictured. Noadditional controller interfaceor conductor cables arerequired.

Alarm Bells To complete your emergencylight upgrade package you’llneed a 6VDC alarm bell. OurNEMA 4/12 alarm bells aredesigned to function with any6VDC power source.

These are standard 6” bells andare easy to install and wire.The sound level at 10 feet is92db. You can mount our bellsup to 1000 feet fromemergency light power supplyno matter what your voltage is.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546734

EEmmeerrggeennccyy LLiigghhttiinngg && AAllaarrmm BBeellllss

ITEM: 742-425-6Alarm Bell 6VDC - NEMA 4/12

ITEM: 716-210-4X-FFlush Emergency Light - 110VAC In 6VDC Out

ITEM: 742-425-6Alarm Bell 6VDC

NEMA 4/12Side View

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 35

Emergency LightingProduct Features• Stainless Steel Seamless NEMA 4X Enclosure• Gasketed Lens• Gasketed Coverplate• Rust and corrosion resistant stainless hardware• 4 Hour Battery

MODELS AVAILABLE716-210-4X-F Emergency Light Unit

Flush Mount716-210-4X-S Emergency Light Unit

Surface Mount

Alarm BellsProduct Features• Powder Coated Alarm Bell• NEMA 4/12 Junction Box• Gasketed Cover• Sound Level at 10 Feet - 92dB

MODELS AVAILABLENEMA4/12-Other Voltages742-425-6 6 Volt Alarm Bell: DC742-425-12 12 Volt Alarm Bell: DC742-425-24 24 Volt Alarm Bell: DC742-425-120 120 Volt Alarm Bell:AC

Ordering Information

ITEM: 716-210-4X-SSurface Mount Emergency Light Shown

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546736

Flush Mount LightsIdeal for both corrosive andwet environments. Housingand lens frame are fully sealedand gasketed to withstandlow-pressure sprayed water(up to 20 psi).

Lens frame is secured withstainless steel screws. Lightshave an acrylic prismatic lensand a white aluminumhousing. They haveknockouts for hard wireconnections and require twostandard fluorescent T12 bi-pin bulbs.

Size: 48" x 11 3/4" x 4 1/2"

Surface Mount LightsTo help seal out moisture,these fluorescent lights have aone-piece impact- and UV-resistant fiberglass-reinforcedpolyester body and are fullygasketed. The acrylic lens andcaptive latches also resistmoisture and dirt.

Lights have knockouts forhard wire connections andmounting.

Wet-location fixtures arefurnished with two gasketed1/2" thread fittings for end-to-end mounting and require twostandard fluorescent T12 bi-pin bulbs.

Size: 50" x 7 5/8" x 4 3/4”

Cab FanThis fan is one speed andbuilt to move 855 CFM ofair. The design allows foreasy installation andwiring.

The 1/4 HP motor isa sealed explosionproof unit. The bladeis aluminum, nonsparking. This unitmeets the requirementsof Class 1, Group DX,Class II Group E,F,G.

This unit comes completewith a grill. Simply cut thetop of the cab for an 12”diameter hole, mount your fanand wire. It’s as easy as 1,2,3.

NEMA 4/12 Cab Light - Flush MountItem: 716-214

NEMA 4/12 Cab Light - Surface MountItem: 716-218

Item: 716-220Cab Fan

CCaabb LLiigghhttiinngg &&CCaabb VVeennttiillaattiioonn FFaann

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 37

Flush Mount Light FixtureProduct Features• Powder Coated Aluminum Housing• Gasketed Lens• Gasketed Coverplate• Rust and corrosion resistant stainless hardware

MODELS AVAILABLEElectronic Start Fixtures - 0 Degrees *716-214 Cab Light Fixture

Flush Mount - 120VAC716-215 Cab Light Fixture

Flush Mount - 277VAC

*Minimum Starting Temperature 0 degrees.

Surface Mount Light FixtureProduct Features• Polycarbonate Housing & Lens• Gasketed Lens• Gasketed Coverplate• Rust and corrosion resistant stainless hardware

MODELS AVAILABLEElectronic Start Fixtures - 0 Degrees*716-218 Cab Light Fixture

Surface Mnt. - 120VAC

*Minimum Starting Temperature 0 degrees.

Cab Ventilation FanProduct Features• Galvanized Housing• Aluminum Fan Blade• Stainless Steel Grill• 855CFM• Explosion Proof Motor 1/4 HP• Single Speed Unit

MODELS AVAILABLENEMA 4 - Dust Tight /Hazardous Loc.716-220 Cab Ventilation Fan,

Sealed Motor, Class 1, Division II System.

*Note due to weight and size requirements unitmay be shipped via truck service.

Ordering Information

NEMA 4 Cab Fan

AdjustableMounting Brackets(4)

NEMA 4/12 Cab Light - Surface MountITEM: 716-218

16” Square

16”

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546738

Pit Switch: NEMA 4XDon’t compromise safety by choosing the cheapest pitswitch on the market today. Choose one that’s going to lastunder in demanding environments. Our NEMA 4X Pit StopSwitch offers the following heavy duty features: Seamlessstainless steel enclosure, 11 gauge stainless steel cover plate,bright red push pull stop button and gasketed cover. Contactblocks are rated for 110-480 VAC.

These switches should be used in every pit where water ispresent or may be present, including incidental water such asfrom mopping or water from boots, shoes, etc. running downthe hatch.

PPiitt SSwwiittcchheessFFoorr WWeett LLooccaattiioonnss

51101-4X - Pit Stop Switch51101-WA - Pit Stop Switch

Pit Switch: WAThe “original” water resistant pit stop switch, the WAfeatures a heavy duty cast aluminum cover plate andenclosure assembly, cast lever and threaded conduitentrance for easy wiring.

Originally designed to handle the higher voltages ofyesterday, 110 - 220 VDC, these switches have leversor buttons that are seated in the coverplate. Thisprevents water from entering the enclosure.

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 39

Pit Switch: NEMA 4XProduct Features• Stainless Steel NEMA 4X Enclosure• Gasketed Pushbutton• Gasketed Coverplate• Engraved Cover Plate• Rust and corrosion resistant stainless • hardware

MODELS AVAILABLENEMA4X-Water/Corrosion Resistant51101-4X Pit Stop Switch51101-4X-LO Pit Stop Switch - LO

With Optional Lockout Tagout Kit

Pit Switch: WAProduct Features• Stainless Steel NEMA 4X Enclosure• Sealed Lever• Gasketed Coverplate• Engraved Cover Plate

MODELS AVAILABLENEMA4/12-Water/Dust Resistant 51101-WA WA Pit Stop Switch-N4Rated for 110V - 220 VAC or DC

Ordering Information

If you run into a situation wherethe elevator pit is considered aconfined space by an OSHASafety Representative then youmay need to upgrade your pitswitch with a lockout tag out kit.Each kit includes Bracket, lock &Tag as shown.

51101-4X-LO - Pit Stop Switchw/Lockout Tag Out Kit

Our heavy duty push pull stop switch issealed to protect against water and dust.

Item: 716-025-C-RSealed Pushbutton Maintained

Car Top StationsIf you’re tired of bent orcrushed car top inspectionstations and want one thatlasts, this station is for you.Many customers install themon all of their jobs. They arevirtually indestructable.

Pit Light/Car BottomPerfect for under the car or pitsthat require a receptacle and alight at the same time. Simplymount on the wall or bottomof the elevator platform and

Light and receptacle areconcealed under aweatherproof cover makingsure the elements do notdamage the electricalequipment. Heavy duty lightand guard ensure thataccidental contact doesn’tdamage it.

additional circuitry to yourcontroller in order for pit floodservice to work correctly.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546740

CCaarr TToopp,, BBoottttoomm,, PPiittLLiigghhttss,, RReecceeppttaacclleess && FFllooaatt SSwwiittcchheess

ITEM: 722-303 NEMA 4X Car TopInspection Station NoteLight Bulb Not Included

ITEM: 722-305 NEMA 4X Car Bottom/PitLight & GFCI ReceptacleNote: Light Bulb Not Included

ITEM: 51101-PFNEMA 4X Pit Float Switch

Pit Water Float SwitchAfter a tragic death where a person drowned in anelevator during tropical storm Allison in Houston,TX, pit float switches have been specified on moreelevators nationwide.

The Elevator Pit Float Switch is designed to close acontact when the water float is activated, 3/4” throwrequired to activate sensor.

Please note that this device is simply a water sensorcontact and does NOT contain the logic, circuitry,relays to actually run the elevator. You may need toadd relays or additional circuitry to your controllerin order for pit flood service to work correctly.

WWaatteerr//CCoorrrroossiioonn RReessiissttaanntt -- NNEEMMAA 44XX && 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 41

Car Top Inspection StationProduct Features• Stainless Steel Seamless NEMA 4X Enclosure• GFCI Receptacle• NEMA4, 12 & 4X Pushbuttons• Rust and corrosion resistant stainless hardware• Gasketed Light Bulb Guard

MODELS AVAILABLE722-303 Car Top Inspection

Station - Complete w/Worklight and GFCIReceptacle

When ordering please indicate voltage required.This is needed so that we can supply the correctfire service buzzer and lamp.

Car Bottom/Pit Light StationProduct Features• Stainless Steel Seamless NEMA 4X Enclosure• GFCI Receptacle• NEMA4, 12 & 4X Pushbuttons• Rust and corrosion resistant stainless hardware• Gasketed Light Bulb Guard

MODELS AVAILABLENEMA4X-Water/Corrosion Resistant722-305 Worklight & Receptacle

Only

Pit Flood/Float SensorPlease note that this device is simply a watersensor contact and does NOT contain the logic,circuitry, or relays to actually run the elevator.You may need to add relays or additionalcircuitry to your controller in order for pit floodservice to work correctly.

Steps that should happen if water is sensed inthe pit and this device is activated shouldinclude the following based on ourrecommendation.

Recommended Operation With pit flood device mounted 1”-2” from pitfloor the following sequence of operationsshould occur. CJA Controllers from 2010 andabove have Pit Flood Circuitry Built In.

1. Pit Flood Sensor Rises and Closes Contact.

2. Closing Contact Connects Back To Controller

3. Elevator Runs To Top Floor, Doors Open and Stay Open

4. All Hall Calls and Car Floor Buttons are Disabled

5. Fault Code On Controller Pit Flood Cannot be Cleared Until Elevator Is Checked By Mechanic/Inspector.

IMPORTANT NOTE: The sequence ofoperation mentioned above is something that2010 and newer CJA Elevator ControlSystems have built into the programming. Ifyour controller is older and/or manufacturedby another company, it may not be able toperform the tasks indicated above. Werecommend that at the very least you areable to add relays so that the elevator runs tothe top floor if the float switch is activatedand stays at the top floor, disabling all carand hall calls until the elevator can beinspected by a trained elevator mechanic.

Product FeaturesControl Interface Options0.40A@ 240 VAC • 0.20A@ 120 VDC0.50A@ 120 VAC • 0.50A@ 24 VDC

MODELS AVAILABLENEMA4X-Water/Corrosion Resistant51101-PF Pit Float Sensor

Ordering Information

Light Switch & GFCI Receptacle Sorry, light bulb not included!

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546742

Lever Operated Fixtures - Car Stations“The Original Waterproof Fixture”

CJA Advertisement/Brochure: Dated - 1960’s 1970’s

WWaatteerr//DDuusstt RReessiissttaanntt -- NNEEMMAA 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 43

The original water resistant fixture. These aregreat for those applications that are as extreme asyou can get. They are also great for buildingsthat are still running high voltage lines, such as220-440VDC.

These lever activated fixtures represented theoriginal CJAwater resistant fixture line. Still indemand today, these fixtures are used forreplacement purposes and new equipment.Specific design features make the lever activatedfixtures water resistant and durable to last inyour harshest environment. They are time testedand industry approved. Shown right is the FW-66 car station. The markings on the cover canbe changed to meet your specifications. Also,levers can be added or subtracted depending onthe number of floors.

Product Features• Any Voltage • Cast Aluminum Cover Plate/ Enclosure • Stainless Steel Cover Legend Plate • Water Resistant Gasketed Coverplate• Lever Buttons are Recessed In Cover Plate• Carbon To Metal Loaded Contacts

MODELS AVAILABLE736-977-8 FW-65 -Up To 8 Levers

Engraved to your specifications

736-977-12 FW-66 - Up To 12 Levers Engraved to your specifications

Please note that the number of levers can be lessor more than specified above. Door Buttons,Fire Service features are also available. Pleasecall for additional information.

FW-66 Car Stations

FW-66 Car Station For Freight ElevatorInstalled in Lime Processing Facility

1970. Still Running Strong Today!

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546744

Lever Operated Fixtures - Hall Stations“The Original Waterproof Fixture”

CJA Advertisement/Brochure: Dated - 1960’s-1970’s

WWaatteerr//DDuusstt RReessiissttaanntt -- NNEEMMAA 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 45

FW Hall Station - Flush MountOldies but goodies. Ideal for extremely toughenvironments such as Cement Facilities, SugarProcessing Plants and other applications wheresticky goo regularly freezes up standardpushbuttons.

Ideal for High Voltage Applications, such as220VDC to 440VDC and for applications wherebuildings have been grandfathered from currentcodes.

We offer many different configurations so pleasecall us if you require features not shown in thissection.

MODELS AVAILABLE73521F-1 FW3-1 Single Lever

Lever (call) and In-Use Light - Flush Mount

73521F-2 FW3-2 Double Lever Lever (call) and In-Use Light - Flush MountIdeal for constant pressure applications

73521F-15 FW-15 Two to TenLevers with Stop Switch and Light SwitchFlush Mount

SW Hall Station - Surface MountSame features as the FW Series except that theseunits are surface mount.

Ideal for High Voltage Applications, such as220VDC to 440VDC and for applications wherebuildings have been grandfathered from currentcodes.

We offer many different configurations so pleasecall us if you require features not shown in thissection.

MODELS AVAILABLE73521S-1 SW3A-1 Single Lever

Lever (call) and In-Use Light - Surface Mount

73521S-2 SW3A-2 Double Lever Lever (call) and In-Use Light -Surface MountIdeal for constant pressure applications

Ordering Information

Above: Side View of FW3-2 ITEM: 73521F-2

FW3-2 - Up/Down Lever &In Use Light

ITEM: 73521F-2SW3A-1 - Call Lever & In Use Light

ITEM: 73521S-1

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546746

SSiiddeewwaallkk,, KKeeyy OOppeerraatteedd SSttaattiioonnssTThhee ““OOrriiggiinnaall”” SSiiddeewwaallkk EElleevvaattoorr SSttaattiioonn

CJA has more sidewalk elevatorrelated equipment in cities all over theworld than any other manufacturer. It amazes mewhen I travel to see SWK and FW stations that are stillworking on a daily basis. Some continue to operate after 50years of service.

The FW station pictured is at the world famous Berghoff Cafe in downtown Chicago,not only was it a great restaurant but a great sidewalk elevator. This station has been installedsince the 1940’s and if it could talk the stories it might tell.

Sidewalk Lift Door

FW Station

Sidewalk Elevators

WWaatteerr//DDuusstt RReessiissttaanntt -- NNEEMMAA 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 47

CJA offers a complete line of key operatedstations for any application, especially thosewhich require moisture and dust protection.Cover plates are available in stainless steel orbronze and have heavy duty cylinders.

Used on sidewalk elevators or platform lifts thatrequire a constant pressure switch to run theplatform up or down.

If the model or features are not shown pleasecall us toll free. We can customize your stationwith almost any feature.

NEMA4X-Water/Corrosion Resistant733-101-S4X SWK-1: 1 Momentary

Key Switch Only733-201-S4X SWK-2: 2 Momentary

Key Switches Only733-301-S4X SWK-3-1: Momentary

Key Sw. & In-Use Lens

NEMA4/12-Water Dust Resistant733-101-S4 SWK-1: 1 Momentary

Key Switch Only 733-201-S4 SWK-2: 2 Momentary

Key Switches733-301-S4 SWK-3-1: 1 Momentary

Key Sw. & In-Use Lens

NEMA 4/12 is manufactured with an aluminumenclosure while NEMA 4X is manufacturingwith a Stainless Steel Enclosure

Ordering Information

733-301-S4 SWK-3-1 Station NEMA 4/12

Momentary Spring Return to Center PositionCam Type Lock With Toggle Switch

Behind Cover Plate.Voltage Rating:

125VAC - 10 amp28VDC - 10 amp

FW Lever Operated Station For ConstantPressure Applications

733-101-S4SWK-1 Station NEMA 4/12Momentary Spring Return to Center PositionSelf Contained Key Switch 700MVoltage Rating:125VAC - 4 amp250VAC - 2 amp

For almost a century C.J.Anderson & Company hasbeen manufacturingcontrollers for both nationaland international markets. Asa pioneer in the field, CJAhasmanufactured thousands ofcontrollers, from tiller ropeand car switch to the presentday microprocessor. With thisvast number of controllers inthe field, most elevatorconstructors or mechanics arefamiliar with CJA’s design,operation and construction. Itis our policy to retain thefamiliar design principleswhile incorporating moderntechnology into the controlsystems.

We specialize in providingcomplete fixture/controlsystem packages for ease ofinstallation. You don’t have toworry about coordinatingschedules and lead times andwill receive a completedpackage on time with all thefeatures for your project. Wealso can provide serial linkwiring for CJAFixture/Control Systempackages which can greatlydecrease your installationtime.

All of the controllers showncan be manufactured to meetthe following standards.• Water Resistant - NEMA 4 • Corrosion Resistant - N4X • Hazardous Location - N7/9 • Dust Proof - NEMA12 • Conventional - NEMA 1

With the advent of computerlogic into the elevator industrythere have been a vast numberof new companies promotingtheir control systems. Manyof these new companies nolonger exist. With C.J.Anderson Control Systemsyou have the assurance thattechnical assistance, wiringdiagrams and replacementparts will be available foryears to come. With CJA youenjoy the benefits of “today’ssystem’s” coupled with yearsof proven reliability, and theconfidence that we will behere in the future.

CJA’s objective is to utilizethe best available technology,equipment selection anddesign which will suit thecontractor’s needs forperformance and cost. Thisincludes the selection of theprocessor, computer software,programming, controlequipment, drives, relays,

resistors, etc. which go intothe final design. Theoverriding goal of the entiresystem is that the final productmust be reliable and costeffective.

Reliability is insured by pre-adjusting at CJA’s factory andthen completely testing thefinished product prior toshipping.

Cost effectiveness is realizedby ease of installation,adjustment and maintenanceafter completion.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546748

EElleevvaattoorr CCoonnttrrooll SSyysstteemmss

NEMA 4 VVVF Elevator Controller

EElleevvaattoorr CCoonnttrroolllleerrss -- NNEEMMAA 44//1122 && 44XX

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 49

VVVF Variable Voltage Variable FrequencyFor traction elevators traveling faster than 100 FPM. Solid Statecontrols, dynamic braking and force guided relays make ourcontrollers the most solid state in the industry. For elevators thatare under 150 feet per minute no encoder feedback from themotor is required. For speeds 150 feet per minute and above werecommend that you use encoder feedback. We can provide anew motor and encoder for your elevator system along with anew controller.

RTC-1 - Soft Start For One Speed MotorsFor traction elevators that travel less than 90 FPM. With thissystem, stopping of the elevator occurs when the elevatorcomes to the floor and the door zone sensor is activated. Thebrake sets and the elevator stops. The slower the elevatorelevator travels the better this controller stops. Motor control isby Power Electronics Smooth Control or soft start from one ofthe other soft start manufacturers.

RTC-2 - Soft Start For Two Speed MotorsFor traction elevators with speeds less than 180 feet per minute.This is a very good alternative for older elevators. Soft startunits are controlled by the Power Electronics 2 Speed SmoothMove. It slowly ramps up into the first motor winding and thenthe second and it also has the ability to slow down when aselector is added to your elevator. We can provide this as a PLCBased system or relay logic without Fire Service for repair orlike for like replacements.

Hydraulic - Soft Start, Wye Delta or SOLOur CJAcontrollers for hydraulic projects are ideal for directreplacement or new installations and have solid state industrytype PLC and components that are readily available and off theshelf in the event of a shut down. Available with Soft Start, WyeDelta or Straight Accross The Line, we can build a controller tomeet your specifications.

VVVF Line RegenLine Regeneration with elevator controllers is being specifiedfor more and more projects. Instead of energy transforming intoheat when the elevator stops and dissipating into a resistor bank,the energy that’s created when the elevator stops gets pushedback into the AC line through a REGEN unit. The upfront costassociated with line regenerative drives is more than atraditional VVVF controller. However over time you’ll knowthat your elevator is conserving what used to be wasted energyand helping in your effort to keep your building green.

SCR - For DC MotorsThey are still out there, elevators running with DC motors. Westill build elevator controllers for these types of applicationsutilizing a solid state SCR Drive. We also use PLC Based logic,encoder feed back and recommend you installing a new lineisolation transformer to ensure that noise and interference iskept to a minimum. There’s still a market for DC controllers, it’sjust not as large as for VVVF AC elevators.

Microprocessor Control (PLC) CJAutilizes the best software and PLC’s to achieve the bestperformance for your elevator. Each Control System has a“brain” which contains a non volatile memory program thatcannot be erased in the event of a power outage.

Microprocessor control allows CJA to upgrade programs in thefuture to allow for code changes and new elevator requirements.We also manufacture controllers using PLC’s that are industrialtype. One of the most popular among the ones we build with isAllen Bradley.

Relay Logic Need Relay Logic? We still make them. Keep in mind that theprice of a Relay based system when compared to aMicroprocessor based system is actually more due to anincreased number of relays and time involved withmanufacturing and testing the controller. Also note that certainFire Service Codes are not available with this type of logic, andSingle Automatic Pushbutton operation can only beaccommodated with elevators over three floors. Ideal forelevator speeds under 100 Feet Per Minute and using motorcontrols that are anything but VVVF. Perfect in some cases forlike for like repair replacements.

Touchscreen DiagnosticsCJAMicroprocessor control systems come equipped with touchscreen controls for monitoring the elevator and reporting faultsof the system, such as bad door interlock contacts. Each LCDscreen is easy to navigate through and also allows the mechanicthe ability to change simple parameters such as door timing andalternative floor for fire service. This is a standard feature on allPLC based controllers.

Easy to Wire Terminal BlocksEasy to view and wire terminal blocks make wiring a breeze.We specifically use easy to wire blocks to help with wiring.

Controller Air Conditioners & HeatersWe can upon request provide cabinet cooled air conditioners toprevent damage to both microprocessor and solid state motorcontrols for excessively hot machine rooms. Available inNEMA 1, 4/12 and 4X, we can easily provide them should yourequire one. Each unit is wired directly in to the control systemand comes with a manually adjusted thermostat. Heaters arealso available for colder climates as well.

Motor ControlConstant Pressure, Car Switch, Single Speed, Two Speed,Hydraulic, Variable Frequency Variable Voltage or DC SCRApplications. We can manufacture your controller for anyhorsepower or elevator speed you need. This is dependent uponwhat type of system you have.

These are just a few of the many features available to you whenyou purchase a CJA Control System. Each control system isbuilt to your job specifications and tested prior to shipping. Call today for controller pricing on your next project.

Controller Types Features & Options

Tape SelectorThe CJAAccu-Track III SelectorSystem is designed to providesolid state car positioning andleveling. It will work with anycontrol system and can provide upto ten relays for a variety offunctions including: door zone,level up, level down and up/downslowdowns, and encoder feedback.

You can wire the unit howeveryou’d like and are not required towire all ten sensors/relays if notnecessary.

Features:• Stainless and Polycarbonate

Construction • Corrosion Resistant • Fasteners• Dry Contacts Rated for 24- • 240VAC or DC• 110VAC to Power Unit• LED Indicators Read • Through the Coverplate• Can be configured for any • controller. • Normally Open Contacts• Nylon Replaceable TapeGuides• 10 Sensors - 5 Positive• 5 Negative• Sealed Halifax Sensors

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546750

EElleevvaattoorr SSeelleeccttoorr SSyysstteemmssFFoorr LLeevveelliinngg,, DDoooorr ZZoonnee && SSllooww DDoowwnn SSiiggnnaallss

Elevator Cab

3rd Floor

2nd Floor

1st Floor

TOP TAPEHOLDER

TAPE

SELECTORHEADMOUNTED ONTOP OF CAR

LEVELING/SLOW DOWNMAGNETS

ADJUSTABLEBOTTOM TAPEHOLDER

RAIL

Item: 636-507- Tape Control Box AssemblyFor complete selector order item: 636-501-3

Accu Track Selector SystemFeatures• Corrosion Resistant Design and Construction• Dry Contact Points - Not Voltage Sensitive• Requires 110VAC Power Supply• Replaceable Sensors & Components• 10 Sensors, Four Separate Lanes

MODELS AVAILABLE636-501-3 Accu-Track Selector

with Ten Sensors

Specify number of floors and elevator hoistwaylength when ordering. For elevators that requiremore than 100 feet of tape the additional amountneeded will be charged a our current per footprice. Note that you may not need all thesensors on the unit.

REPLACEMENT COMPONENTS636-514 Tape Guides - Plastic Heavy

Duty - Four Required Per Accu Track

636-517-POS Magnets for Accu-TrackPositive

636-517-NEG Magnets for Accu-TrackNegative

636-507 Accu - Track Control Box636-518 Tape Reader Assembly636-516 Selector Tape 3” Wide

Priced By Foot

SSeelleeccttoorr SSyysstteemmss -- NNEEMMAA 44//1122 && 44XX

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 51

Ordering Information

Item: 636-514Each Accu-Track Comes

with 100 Feet of Tape

Item: 636-518 -Accu-Track Tape Reader

Assembly

Item: 636-501-3Accu-Track Complete Package1. Control Box Assembly - 636-5072. Wiring Harness - Comes With Tape Head3. Top Tape Holder4. Bottom Tension Tape Holder5. Accu Track Tape Reader w/Sensors - 636-5186. Magnets, Magnet7. Magnet Layout Tool

Roll of 3” Stainless Steel Tape shown above. .

1.

2.

3.4.

5.

6.

7.

Complete PackagesCJAHatch Switch Packagesare ideal for any newinstallation or modernization.

Available in two differenttypes of sealed packages,simply choose between highspeed and lower speedNEMA 4/12 applications

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546752

HHaattcchh SSwwiittcchh PPaacckkaaggeess

Item: 535-151C-8 Limit Switch - 1 Normally ClosedContact Gasketed Cover & Nylon Bearing

Item: 535-701-WPSL Limit Switch - 2 Normally Open, 2Normally Closed Contacts Gasketed Cover &Nylon Bearing - Used on our 8 SwitchPackages

NEMA 4 Switch PackagesFeatures• Die Cast Bodies & Covers• Heavy Duty Contacts• Sealed Contacts• Replaceable Components• Turn to Page 184 For More Switch Contact • Configurations & Models

MODELS AVAILABLECJA-HSP-N4 Standard Hatch Switch

Package - NEMA 4/12

Each Package Includes: 2 C-8’s, 2 C-81’s, 2 CB-51’s, 6 Limit Switch Mounting Brackets and 1Four Foot Long Car Riding Cam. If you requirea different contact arrangement please let usknow and we can provide any that you need.

CJA-HSP-8-4 High Speed Switch PackageSL Switches - NEMA 4/12

Each Package Includes: 8 SL’s, 8 Limit SwitchMounting Brackets & 8 Foot Car Riding Cam

HHaattcchh SSwwiittcchh PPaacckkaaggeess -- NNEEMMAA 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 53

Ordering Information

Item: CJA-HSP-4Hatch Switch Package

6 Limits, 6 Mounting Brackets, 1 Car Riding Cam

C-8 WP - 1 N.C. Contact& Mounting Bracket

C-81 WP - 1 N.C. Contact& Mounting Bracket

CB-51 WP - 1 N.O. & 1 N.C. Contact& Mounting Bracket

CB-51 WP - 1 N.O. & 1 N.C. Contact& Mounting Bracket

C-81 WP - 1 N.C. Contact& Mounting Bracket

C-8 WP - 1 N.C. Contact& Mounting Bracket

4 Foot CarRiding Cam

SL-WP - 2 N.O. & 2 N.C. Contacts& Mounting Brackets

8 Foot CarRiding Cam Item: CJA-HSP-8

Hatch Switch Package8 Limits, 8 Mounting Brackets,

1 Car Riding Cam

Motors - SealedThe W21™ Severe DutyHigh Efficiency motors aredesigned to meet or exceed allEPAct requirements forenergy efficiency as definedby the DOE. The efficiencyvalues are certified accordingto the DOE's regulations(Certificate of Compliancenumber CC029A).

W21™ motors meet the mostdemanding severe dutyapplication requirements.These TEFC motors are allcast iron construction, withenclosures rated IP55 tohandle wet and dirtyenvironments. They arepainted with a special system,using synthetic enamel alkydresin paints, which exceed theASTM B117 standard for salt

spray test. The W21™ line israted for 1.25 Service Factorup to 100HP and meet DesignB (up to 100HP) and DesignC (from 15HP up to 100HP)torque requirements. This lineis rated for dual frequency anddual voltage (with reducedservice factor) up to 60 HP.And the entire line is certifiedInverter Rated for use with aVFD. This rating meets orexceeds MG1 Part 31 NEMASpecifications.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546754

MMoottoorrss aanndd EEnnccooddeerrss

Sealed MotorFoot Mount

Encoders - SealedFor applications that require encoder feedbackwe offer a sealed unit that can be purchasedseparately or added to any motor.

For elevator speeds over 150 FPM werecommend utilizing encoder feed back with aVVVF drive. We also recommend encoder feedback when car capacities are much larger thanthe normal elevator.

Sealed Encoder

WWaatteerr//DDuusstt RReessiissttaanntt -- NNEEMMAA 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 55

Motors - NEMA 4 -TEFC - IP55Product Features• Squirrel Cage Rotor / Aluminum Die Cast• Class F Insulation• Totally Enclosed Fan Cooled - TEFC (IP55) • water tight and dust tight enclosure• Non Sparking Fan• Division 1, Class I, Groups C and D• Division 1, Class 2, Groups F and G• Voltage: 208-230/460V, 200V, 460V or 575V• Service Factor: 1.25 up to 100HP• Continuous duty (S1)• 104ºF (40ºC) ambient temperature • Altitude: 3300 ft (1000m)• Call for pricing for Encoder Kits

MODELS AVAILABLE - W/O ENCODER363-276-WP5 5 HP-1200 RPM

215T Frame, 208-230/460V363-276-WP7.5 7.5 HP-1200 RPM

254T Frame, 208-230/460V363-276-WP10 10 HP-1200 RPM

256T Frame, 208-230/460V363-276-WP15 15 HP-1200 RPM

854T Frame, 208-230/460V363-276-WP20 20 HP-1200 RPM

286T Frame, 208-230/460V363-276-WP25 25 HP-1200 RPM

324T Frame, 208-230/460V363-276-WP30 30 HP-1200 RPM

326T Frame, 208-230/460V363-276-WP40 40 HP-1200 RPM

364T Frame, 208-230/460V363-276-WP50 50 HP-1200 RPM

365T Frame, 208-230/460V363-276-WP60 60 HP-1200 RPM

404T Frame, 208-230/460V363-276-WP75 75 HP-1200 RPM

405T Frame, 208-230/460V

Note: We Carry Other RPM’s & Higher HPMotors! Call us toll free for more information.

Harsh Duty EncodersProduct Features• 1024PPR Encoder• Mounting Kit Included• NEMA 4 • Available as Add On To Motor Shown

MODELS AVAILABLE363-276-ENC HS-35 - 1024 PPR

NEMA 4 Encoder

If you would like us to mount the encoder on amotor shown right please specify this in yourpurchase order.

Ordering Information

Knock Out PunchesUnless you specify whereyou’d like conduit entrancesyou’re going to need to installthem in the field. We’ve foundthat this is really the best placeto do so.

We offer two different sets,one for mild steel which workjust fine for our 14 gaugeNEMA 4X enclosures and aheavier duty set that canpunch holes in 10 gaugestainless steel.

We also carry the replacementdraw bars as well as newpunches for your set as theywear out. Please call us if youneed them replaced.

Conduit FittingsOur WH Series die cast waterproof hubs come in a varietyof sizes for your waterproofing needs.

Available in Stainless Steeland Zinc Die Cast. Call forpricing on your next project.

Junction BoxesAny size you’d like, just let usknow. All enclosures havemounting means external tothe equipment cavity and arerated NEMA 4X.

Need terminal blocks? Just letus know how many you needand we will install them foryou. We use DIN railmounted snap on terminals tomaximize space.

Junction boxes do not haveany conduit holes. You needto install them in the field asyou require or ask us to installthem for you.

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 546756

TToooollss,, FFiittttiinnggss aanndd JJuunnccttiioonn BBooxxeessTToo MMaakkee YYoouurr IInnssttaallllaattiioonn EEaassiieerr

Item: 639-101For Making Holes in Stainless Steel

Up To 10 Gauge and comes with hydraulic tool.

Item: 639-100For Making Holes In Mild Steel - Works on CJA NEMA 4X

Enclosures but wears quicker than the unit shown right.

Die Cast Water Proof Conduit Hubsare Required for ANY

C.J. Anderson & CompanyNEMA 4X Fixture.

Some locations may require stainlesssteel conduit, trough and hub fittings.

WWaatteerr//DDuusstt RReessiissttaanntt -- NNEEMMAA 44//1122

Order Toll-Free: 1 800 252 1910 • www.cjanderson.com • Fax: 1 708 867 5467 57

Knock Out (KO) Punch SetProduct Features• 4 Piece for Milder Metals• 6 Piece for Stainless Steel • 11 Ton Hydraulic Driver Ram (639-101)• 5 Punches for Holes Listed Below SS• 7/8”, 1 7/64”, 1 23/64”, 1 15/16”, 2 3/8” • 4 Punches for Holes Listed Below (639-100)• 7/8”, 1 7/64”, 1 23/64”, 1 11/16”

MODELS AVAILABLE639-100 4 Piece Self Centering Set

For Mild Steel 639-101 6 Piece Self Centering

Knock Out Set With Hydraulic Driver - for up to10 Gauge Stainless Steel

Enclosure FittingsProduct Features• Heavy Duty, Die Cast or Stainless Steel• Sealing O Ring Neoprene Washer• Easy to Install

MODELS AVAILABLEHUBS BELOWARE ZINC DIE CASTWH-1 1/2” WH Hub: Die CastWH-2 3/4” WH Hub: Die CastWH-3 1” WH Hub: Die CastWH-4 1-1/4” WH Hub: Die CastWH-5 1-1/2” WH Hub: DieCastWH-6 2” WH Hub: Die Cast

HUBS BELOWARE TYPE 304 SSWH-1-S 1/2” WH Hub: StainlessWH-2-S 3/4” WH Hub: StainlessWH-3-S 1” WH Hub: Stainless

Junction & Conduit BoxesProduct Features• Stainless Steel Construction• Enclosure Mounting External• Any size you need just call• We can provide terminals as well

Please call and let us know how many terminalsyou require and we’ll determine the sizeenclosure you’ll need. Dont’forget about theconduit hub fitttings for your enclosure!

Ordering Information

Standard Knock Out PunchUsed In 639-100 Kit

NEMA 4X Junction Boxes come in a variety ofsizes. We can even install terminals in them on din rail.

Call for a price quote today!

1/2” Zinc Die CastWH Hub

WH-1