PROSTHETICSURGICAL

CATALOGUE

BTI implant system

Page 2: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 2 |

Published byTEAM WORK MEDIA ESPAÑA© EDUARDO ANITUA ALDECOA

Photographs and infographics© BTI Biotechnology Institute

Layout and designTEAM WORK MEDIA ESPAÑA

Vitoria-Gasteiz · Spain 2016

All rights reserved. This manual may not be reproduced, saved in a retrieval system or transmitted in any way, by means of any procedure, whether mechanical, electronic, photocopies, slides, scanning or any other, without prior written permission from the author.

Page 3: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 3 |

ABOUT THIS CATALOGUE

This catalogue contains all of the surgical and prosthetics products by BTI Biotechnology Institute and sets out their specifications and other information that may be relevant to the user.

You can find more detailed information on some of the products using the links marked with this icon + .

For further information you can also consult the website: www.bti-biotechnologyinstitute.com.

Page 4: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 4 |

CONTENTS

Page 5: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 5 |

BTI IMPLANTS .......................................................................................................................................................... 6

CLINICAL-PROSTHETIC COMPONENTS ....................................................................................................... 18

INSTRUMENTS FOR SURGERY .......................................................................................................................... 70

INSTRUMENTS FOR PROSTHODONTICS ...................................................................................................... 84

SURGICAL INSTRUMENTS AND KITS .............................................................................................................. 94

DEVICES ....................................................................................................................................................................104

MICROIMPLANTS FOR ORTHODONTICS .....................................................................................................108

BLOCK GRAFTS KIT ...............................................................................................................................................110

KITS FOR OBTAINING Endoret® (PRGF®) ......................................................................................................112

BTI-SCAN® 3 ............................................................................................................................................................116

CLEANING AND STERILISATION .....................................................................................................................120

LIST OF BTI PATENTS ...........................................................................................................................................127

Page 6: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 6 |

BTI IMPLANTSNarrowUniversalUniversal PlusWide

The Interna® connection by BTI has the following main features:

· Exclusive four-lobe anti-rotation design.· Entrance cone to facilitate the insertion of prosthodontic components.· Designed to withstand high torques without the connection suffering deformations.

· The most advanced design technologies have been used to calculate the stress distribution.

· Guaranteed bone stability around the implant thanks to the study of the load stress distribution.

· The dimensions maximise material in critical areas and thus increase resistance to breakage and fatigue.

· The dimensions of the connection are always the same for all implants, regardless of the platform.

The BTI Externa® connection is characterised by:

Having a hexagon with different side and height dimensions depending on the implant platform. This design is a result of the indications of the implants, therefore, the Wide platform implants will have a larger hexagon than the universal platform implants, as they are indicated for giving pros-thetic solutions to those areas of the mouth with greater biomechanical requirements.

Children: Permanent implants are not intended for use in children who have not concluded their growth and development stages.

Women who are pregnant or breastfeeding: There are no additional preventive measures other than those generally accepted in oral implantology techniques. However, these par-ticular situations should be considered by the clinician before placing the implants.

Re-use and/or re-sterilisation of implants may cause risk of infection and/or cross con-tamination.

Page 7: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 7 |

TECHNICAL SPECIFICATIONS BTI implants

Two connections. Three different platform diameters with the wid-est range of prosthodontic components on the market.

The optima® surface is adapted to the dif-ferent tissues in contact with the implant in order to promote and accelerate osseoin-tegration.

NECK

The optima® surface up to the platform is adapted to favour the retention of marginal tissues and reduce the risk of periimplantitis.

CRESTS

The optima® surface of the threads pre-sents a porosity that allows bone anchoring to its exterior, favouring the initial stability and improving osseointegration.

VALLEYS

The optima® surface of the valleys pre-sents an ideal average roughness suitable for guiding the bone growth between the threads at the same time as maintaining the mechanical properties of the implant.

The unicCa® surface is a chemical modifi-cation with calcium ions, thus providing a number of advantages:

ADHESIVE AND PLATELET-ACTIVATING

Reduces regeneration times.

OSTEOGENIC

Induces the formation of bone tissue.

PROCOAGULANT

Provides immediate stability.

ANTIBACTERIAL

Significantly minimises the risk of periim-plantitis.

ELECTROPOSITIVE, CLEAN AND ACTIVE

Maintains the superhydrophilic properties.

TRIPLE ROUGHNESS

Optimises the adaptation to the different tissues and improves osseointegration.

There are two possible apexes for BTI implants:

1. An apex with exceptional advance/drive capacity and a small apical surface that prevents compres-sion at this level, providing control of the direction and the location of the implant in narrow alveolar crests. It also provides a greater osseointegration surface. This is the standard apex.

2. An apex with a lower advance/drive capacity and large apical surface adapted to achieve primary stability without compression in anatomical areas where significant injury to structures is possible such as to the maxillar sinus and dental nerve. Designed for extra-short implants.

Transporter with depth marks and with the reproduction of the connection on the same, to control its positioning.

optima®unicCa®(Surface optima® + Ca)

APEX

INTERNA CONNECTION

TRANSPORTER

TWO SURFACES

EXTERNA CONNECTION

1st

2nd

3rd

1o

2o

3o

Page 8: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 8 |

NARROW IMPLANTNarrow platform Ø 3.5 mm.Interna ConnectionExterna Connection = Tiny®

+ More information about the Tiny® implants and their prosthetic components on the website: www.bti-biotechnologyinstitute.es

upper maxilla

lower maxilla

Tiny® implants will be the choice for lower incisors, upper lateral incisors and agenesic teeth. In addition, those with a diameter of 3.5 and 3.75 mm are in-dicated for premolars, when the pros-thetic space is complicated.

Narrow implants will be the choice for lower incisors, upper lateral incisors and agenesic teeth. In addition, those with a diameter of 3.5 and 3.75 mm are in-dicated for premolars, when the pros-thetic space is complicated.

Diámetros

Lengths

Longitudes

INTERNA CONNECTION

EXTERNA CONNECTION = TINY®Exterior hexagon 2.5 x 1.1 mm

Diameters

IDEAL POSITION OF THE TINY IMPLANTS®

Page 9: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 9 |

FAMILYNarrow

EXTERNA CONNECTION

INTERNA CONNECTION

2,5 mm ø

3,3 mm ø

3,5 mm ø

3,0 mm ø

3,5 mm ø

3,75 mm ø

3,3 mm ø

3,75 mm ø

IRTCA2585IRTCA2510IRTCA2511IRTCA2513IRTCA2515

Ref.2,52,52,52,52,5

ø8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

Length

IIPECA3375IIPECA3385IIPECA3310IIPECA3311IIPECA3313IIPECA3315

Ref.3,33,33,33,33,33,3

ø7,5 mm.8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

Length

IRTCA3385IRTCA3310IRTCA3311IRTCA3313IRTCA3315

Ref.3,33,33,33,33,3

ø8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

LengthIRTCA3085IRTCA3010IRTCA3011IRTCA3013IRTCA3015

Ref.3,03,03,03,03,0

ø8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

Length

IIPECA3565IIPECA3575IIPECA3585IIPECA3510IIPECA3511IIPECA3513IIPECA3515

Ref.3,53,53,53,53,53,53,5

ø6,5 mm.7,5 mm.8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

Length

IRTCA3565IRTCA3575IRTCA3585IRTCA3510IRTCA3511IRTCA3513IRTCA3515

Ref.3,53,53,53,53,53,53,5

ø6,5 mm.7,5 mm.8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

LengthIRTCA3745IRTCA3755IRTCA3765IRTCA3775IRTCA3785IRTCA3710IRTCA3711IRTCA3713IRTCA3715

Ref.3,753,753,753,753,753,753,753,753,75

ø4,5 mm.5,5 mm.6,5 mm.7,5 mm.8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

Length

Neck with Ø 4 mm

IIPECA3755IIPECA3765IIPECA3775IIPECA3785IIPECA3710IIPECA3711IIPECA3713IIPECA3715

Ref.3,753,753,753,753,753,753,753,75

ø5,5 mm.6,5 mm.7,5 mm.8,5 mm.

10,0 mm.11,5 mm.13,0 mm.15,0 mm.

Length

Page 10: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 10 |

UNIVERSAL IMPLANTUniversal Platform Ø 4.1 mmInterna/Externa Connection

+ More information about the Universal implants and their prosthetic components on the website: www.bti-biotechnologyinstitute.es

Diameters

Lengths

Lengths

INTERNA CONNECTION

EXTERNA CONNECTIONExterior hexagon 2.7 x 0.7 mm

upper maxilla

lower maxilla

Diameters

The universal platform implants are indicated for situations with narrow alveolar crest, in anterosuperior areas or in middle areas of the mouth, to re-store canine and premolar teeth.

IDEAL POSITION OF IMPLANTS OF BOTH CONNECTION TYPES

Page 11: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 11 |

FAMILYUniversal

3.3 mm ø

4.0 mm ø

3.5 mm ø

3.75 mm ø

4.25 mm ø

3.75 mm ø

4.0 mm ø

IIPUCA3755IIPUCA3765IIPUCA3775IIPUCA3785IIPUCA3710IIPUCA3711IIPUCA3713IIPUCA3715

Ref.3.753.753.753.753.753.753.753.75

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IRPU4065IRPU4075IRPU4085IRPU4010IRPU4011IRPU4013IRPU4015IRPU4018

Ref.4.04.04.04.04.04.04.0 4.0

ø6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm 18.0 mm

Length

IIPUCA3385IIPUCA3310IIPUCA3311IIPUCA3313IIPUCA3315

Ref.3.33.33.33.33.3

ø8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IIPUCA4255IIPUCA4265IIPUCA4275IIPUCA4285IIPUCA4210IIPUCA4211IIPUCA4213IIPUCA4215

Ref.4.254.254.254.254.254.254.254.25

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

LengthIIPUCA4055IIPUCA4065IIPUCA4075IIPUCA4085IIPUCA4010IIPUCA4011IIPUCA4013IIPUCA4015IIPUCA4018

Ref.4.04.04.04.04.04.04.04.04.0

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm18.0 mm

Length

IIPUCA3555IIPUCA3565IIPUCA3575IIPUCA3585IIPUCA3510IIPUCA3511IIPUCA3513IIPUCA3515

Ref.3.53.53.53.53.53.53.53.5

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IRPU3765IRPU3775IRPU3785IRPU3710IRPU3711IRPU3713IRPU3715

Ref.3.753.753.753.753.753.753.75

ø6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

INTERNA CONNECTION

EXTERNA CONNECTION

Neck with Ø 4.25 mm

Page 12: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 12 |

UNIVERSAL PLUS IMPLANTUniversal Platform Ø 4.1 mm Interna/Externa Connection

+ More information about the Universal Plus implants and their prosthetic components on the website: www.bti-biotechnologyinstitute.es

Diameters

Lengths

Lengths

INTERNA CONNECTION

EXTERNA CONNECTIONExterior hexagon 2.7 x 0.7 mm

Diameters

lower maxilla

upper maxilla

The implants of the Universal Plus platform are indicated for immediate placement in a post-extraction alveo-lus and are ideal for bridge abutments in areas of canines and premolars. They can also be used individually in central upper and molar areas, but above all when there is a significant biomechanical requirement and it is necessary to be more stringent with the maintenance of soft tissue.

IDEAL POSITION OF IMPLANTS OF BOTH CONNECTION TYPES

Page 13: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 13 |

FAMILYUniversal Plus

INTERNA CONNECTION

EXTERNA CONNECTION

4.5 mm ø

5.5 mm ø4.5 mm ø

5.0 mm ø

5.0 mm ø

IIPSCA4555IIPSCA4565IIPSCA4575IIPSCA4585IIPSCA4510IIPSCA4511IIPSCA4513IIPSCA4515

Ref.4.54.54.54.54.54.54.54.5

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IRPS4565IRPS4575IRPS4585IRPS4510IRPS4511IRPS4513IRPS4515

Ref.4.54.54.54.54.54.54.5

ø6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IIPSCA5555IIPSCA5565IIPSCA5575IIPSCA5585IIPSCA5510IIPSCA5511IIPSCA5513

Ref.5.55.55.55.55.55.55.5

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm

Length

IIPSCA5055IIPSCA5065IIPSCA5075IIPSCA5085IIPSCA5010IIPSCA5011IIPSCA5013IIPSCA5015

Ref.5.05.05.05.05.05.05.05.0

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IRPS5065IRPS5075IRPS5085IRPS5010IRPS5011IRPS5013IRPS5015

Ref.5.05.05.05.05.05.05.0

ø6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

Neck with Ø 4.5 mm Neck with Ø 5 mm

Neck with Ø 5.5 mmNeck with Ø 4.5 mm Neck with Ø 5.0 mm

Page 14: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 14 |

Wide IMPLANTWide platform Ø 5.5 mm Interna/Externa Connection

+ More information about the Wide platform implants and their prosthetic components on the website: www.bti-biotechnologyinstitute.es

The implants of the Wide platform are ideal for obtaining good initial stability and good stress distribu-tion for upper and lower molars. They are particularly useful in cases of post-extraction implant place-ments and in single molars, above all in the upper maxilla.

Diameters

Lengths

Lengths

INTERNA CONNECTION

EXTERNA CONNECTIONExterior hexagon 3.3 x 1.1 mm

Diameters

upper maxilla

lower maxilla

IDEAL POSITION OF IMPLANTS OF BOTH CONNECTION TYPES

Page 15: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 15 |

FAMILYWide

6.0 mm ø5.0 mm ø

5.0 mm ø

6.25 mm ø

5.5 mm ø

5.5 mm ø

INTERNA CONNECTION

EXTERNA CONNECTION

IIPACA5055IIPACA5065IIPACA5075IIPACA5085IIPACA5010IIPACA5011IIPACA5013IIPACA5015

Ref.5.05.05.05.05.05.05.0

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IRPA5075IRPA5085IRPA5010IRPA5011IRPA5013IRPA5015

Ref.5.05.05.05.05.05.0

ø7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IIPACA6055IIPACA6065IIPACA6075IIPACA6085IIPACA6010IIPACA6011IIPACA6013

Ref.6.06.06.06.06.06.06.0

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm

LengthIIPACA5555IIPACA5565IIPACA5575IIPACA5585IIPACA5510IIPACA5511IIPACA5513IIPACA5515

Ref.5.55.55.55.55.55.55.55.5

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IRPA5575IRPA5585IRPA5510IRPA5511IRPA5513IRPA5515

Ref.5.55.55.55.55.55.5

ø7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm15.0 mm

Length

IIPACA6255IIPACA6265IIPACA6275IIPACA6285IIPACA6210IIPACA6211IIPACA6213

Ref.6.256.256.256.256.256.256.25

ø5.5 mm6.5 mm7.5 mm8.5 mm

10.0 mm11.5 mm13.0 mm

Length

Neck with Ø 6.0 mm

Neck with Ø 6.25 mm

Page 16: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 16 |

EXPANDER IMPLANTS TRANSITIONAL

+ More information about the expander implants in the brochure “BTI solutions for atrophic maxillae”.

The expander implants by BTI are the perfect alternative and complement for conventional bone expansions. They are transitional implants that are inserted in the alveolar bone crest when there is not enough width to fit a definitive TINY® implant. They are, therefore, an alternative to block bone grafts for the reconstruction of the atrophic alveolar process.

They have a specific surface treatment that increases bone apposition, but different to that carried out on definitive implants, making their explantation easier.

Page 17: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 17 |

FAMILYExpander Implants

2.5 mm ø 3.0 mm ø

2.5 mm ø 3.0 mm ø

SHORT

LONG

IET2511Ref.

2.5ø

11.5 mmLength

IET3085Ref.

3.0ø

8.5 mmLength

IET2585Ref.

2.5ø

8.5 mmLength

IET3011Ref.

3.0ø

11.5 mmLength

Page 18: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 18 |

CLINICAL-PROSTHETICCOMPONENTSNarrow platformUniversal PlatformWide platform

This chapter presents all of the attachments for making both cemented and screw-retained provisional and/or final prostheses. It will set out the techni-cal specifications of each of them and provide a basic explanation of how to perform the prosthetic work.

Women who are pregnant or breastfeeding: There are no additional precautions other than those generally contemplated in techniques of oral implantology.

Page 19: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 19 |

NEW SURFACE TREATMENT TI-GOLDEN Abutments

· Golden finish: The golden colour achieves a significantly aesthetic improvement by transmitting a greater warmth to the gingival tissues.

BTI prosthetic attachments are evolving to improve the quality of the prosthetic work. Ti-Golden is a coating that improves the aesthetics and the biological interface by de-creasing the accumulation of the bacterial plaque.

ADVANTAGES

· Improves the antimicrobial properties: The bacterial colonisation decreases, there-fore minimising the risk of periimplantitis.

· At gingival level: Improved union of hemidesmosones to the new surface, improving the biological seal.

Standard abutment

Standard abutment

Ti Golden abutment

Ti Golden abutment

95

94

93

92

91

90

0cell

viab

ility

90.6

94BIOCOMPATIBILITY OF GINGIVAL FIBRO-BLASTS / INCREASED GX1

“IMPROVED ANTIMICROBIAL PROPERTIES”

60

45

30

15

00

15

30

45

60

Bact

eria

l adh

esio

n (x

104 ·

cm-2

)

30

52

22

39

Page 20: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 20 |

HEALING ABUTMENT

The slotted healing abutments are transepithelials made from commercially pure titanium with a smooth external surface finish that enables perfect healing of the soft tissues. They can be cut with thick diamond drills and pol-ished with fine grain drills and rubber if it is necessary to customise the outline. (E.g. in case of pressure in the space of the papilla).

The Interna connection abutments are supplied sterile in heat sealed blister packs. Thus they can be used in the pa-tient's mouth straight from the package, without needing to be sterilised in the clinic. The Externa connection abut-ments do not come in blister pack.

The new expanded healing abutments have a wider geometry in the supragingival part. Available for Interna con-nection, universal platform with expanded diameter from 4.1mm to 6 mm (total height 5 and 6 mm) and wide plat-form with expanded diameter from 5.5 mm to 7 mm (total height 5 and 6 mm).

As main advantage, this expanded platform protects the soft tissue during the osseointegration period.

Both abutments are retained directly into the implant (with a torque of 20 Ncm) in the first surgery for single stage implants, or when the second surgery is performed, in cases of two-stage implants.

* BTI recommends using the narrowest abutment, provided this is possible, to gain gingival width, so the papilla will have greater irrigation and consequently, less recession.

Re-use and/or re-sterilisation of these single-use products may cause risk of infection and/or cross contamination.

INTERNA AND EXTERNA

Page 21: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 21 |

FAMILYHealing abutment

Narrow

Universal

Universal Plus

Wide

INTERNA®

EXTERNA®

Slotted abutmentEmergence profile Ø of 4.0 mm

Emergence profile Ø of 4.0 mm

Emergence profile Ø of 5.0 mm

Expanded healing abutments Expanded healing abutments

Emergence profile Ø of 5.0 mm

Emergence profile Ø of 3.5 mm

Emergence profile Ø of 3.5 mm Slotted abutmentEmergence profile Ø of 5.5 mm

Emergence profile Ø of 5.5 mm

Emergence profile Ø of 6.5 mm

Emergence profile Ø of 6.5 mm

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

PCT32PCT33PCT34PCT35PCT36

3.53.53.53.53.5

2 mm.3 mm.4 mm.5 mm.6 mm.

INPCUR41INPCUR42INPCUR43INPCUR44INPCUR45INPCUR46INPCUR48

4.04.04.04.04.04.04.0

1 mm.2 mm.3 mm.4 mm.5 mm.6 mm.8 mm.

PCU42PCU43PCU44PCU46PCU48

4.04.04.04.04.0

2 mm.3 mm.4 mm.6 mm.8 mm.

INPCUR52INPCUR53INPCUR54INPCUR55INPCUR56INPCUR58

5.05.05.05.05.05.0

2 mm.3 mm.4 mm.5 mm.6 mm.8 mm.

INPCUREX45INPCUREX46

4-64-6

5 mm.6 mm.

INPCER31INPCER32INPCER33INPCER34INPCER35

INPCER42INPCER43INPCER44

3.53.53.53.53.5

3.53.53.5

1 mm.2 mm.3 mm.4 mm.5 mm.

2 mm.3 mm.4 mm.

INPCAREX55INPCAREX56

5.5-75.5-7

5 mm.6 mm.

PCU52PCU53PCU54PCU56PCU58

5.05.05.05.05.0

2 mm.3 mm.4 mm.6 mm.8 mm.

INPCAR51INPCAR52INPCAR53INPCAR54INPCAR55INPCAR56INPCAR58

5.55.55.55.55.55.55.5

1 mm.2 mm.3 mm.4 mm.5 mm.6 mm.8 mm.

PCA53PCA54PCA56PCA58

5.55.55.55.5

3 mm.4 mm.6 mm.8 mm.

INPCAR62INPCAR63INPCAR64INPCAR65

6.56.56.56.5

2 mm.3 mm.4 mm.5 mm.

PCA63PCA64PCA66PCA68

6.56.56.56.5

3 mm.4 mm.6 mm.8 mm.

They have a small slot which can be used if the hexagon of the abutment is stripped, so it can be removed with a flat head screwdriver.

The longest abutments (6-8 mm) with the externa connection, as do not have the slot in the coronal area can be used as abutments for occlusal registration; in this case, the occlusion will be taken as the abutments were the teeth.

Page 22: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 22 |

IMPRESSION COPINGS AND OCCLUSAL REGISTRATION INDICATORS

IMPRESSION COPINGS

This part is used to make impressions directly to the implant or to a transepithelial abutment. Individual fenes-trated trays or disposable perforated plastic trays are used for the indirect technique and closed trays are used for the direct technique.

They are manufactured from commercially pure titanium and consist of two parts, the body that has the shape of the connection and the screw that must be tightened manually or with a large hexagon screwdriver. In the indirect technique, this screw must be loosened once the impression material has set and before removing the tray from the patient's mouth.

The copings for the direct technique are made of steel AISI303.

OCCLUSAL REGISTRATION INDICATORS

These are used for occlusal registration in edentulous patients in cases of immediate load.They are screwed directly onto transepithelial abutments with the DIRO screwdriver before making impressions.

INTERNA AND EXTERNA

Page 23: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 23 |

FAMILYDirect-to-implant impression copings

Narrow

Universal

Universal Plus

Wide

INTERNA®

EngagingEmergence profile Ø of 4.0 and 5.0 mm

Non-engagingEmergence profile Ø of 5.0 mm

EngagingEmergence profile Ø of 5.5 and 6.5 mm

EngagingEmergence profile Ø of 3.5 mm

Non-engagingEmergence profile Ø of 5.5 mm

Ref. Ø Length Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Lengt

Ref.

Ref. Ø Length

INCIIE3INCIIE4

3.54.5

12 mm.12 mm.

INCIIU41INCIIU4INCIIU51INCIIU5

4.04.05.05.0

9 mm.12 mm.

9 mm.12 mm.

INCIRIU51

INCIRIU5

5.05.0

9 mm.12 mm.

INCIIA51INCIIA5INCIIA61INCIIA6

5.55.56.56.5

9 mm.12 mm.

9 mm.12 mm.

INCIDU2INCIDU3INCIDU4

4.04.04.0

2 mm.3 mm.4 mm.

INCIRIA51INCIRIA5

5.55.5

9 mm.12 mm.

INDIRECT TECHNIQUE

DIRECT TECHNIQUE

INCIDA 5.5

General information on copings for the indirect technique

Engaging: · Single prostheses · Multiple cemented prostheses

Non-engaging: · Multiple screw-retained prostheses

SID (5 units)

Ref. Ø

Page 24: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 24 |

Narrow

Universal

Universal Plus

Wide

EXTERNA®

EngagingEmergence profile Ø of 3.5 mm

Ref. Ø LengthCIITE 3.5 12 mm.

INDIRECT TECHNIQUE

EngagingEmergence profile Ø of 4.0 and 5.0 mm ø.

Ref. Ø LengthCIIU4CIIU5

4.05.0

12 mm.12 mm.

Non-engagingEmergence profile Ø of 4.0 mm

Ref. Ø LengthCIRIU4 4.0 12 mm.

EngagingEmergence profile Ø of 5.5 and 6.5 mm

Ref. Ø LengthCIIA5CIIA6

5.56.5

12 mm.12 mm.

Non-engagingEmergence profile Ø of 5.5 mm

Ref. Ø LengthCIRIA5 5.5 12 mm.

Non-engagingEmergence profile Ø of 3.5 mm

Ref. Ø LengthCIRIT4 3.5 12 mm.

DIRECT TECHNIQUE

Ref. Ø Ref. Ø CIDT 3.5

Ref. Ø LengthCIDU 4.0 12 mm. CIDA 5.5

General information on copings for the indirect technique

Engaging: · Single prostheses · Multiple cemented prostheses

Non-engaging: · Multiple screw-retained prostheses

Page 25: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 25 |

FAMILYCopings on transepithelials

OCCLUSAL REGISTRATION INDICATORS

Narrow

Universal

Universal Plus

Wide

UNIT TRANSEPITHELIAL

Indirect technique Straight

Indirect TechniqueStraight

Indirect TechniqueStraight

Straight

Indirect technique Angled 17º

Angled 17º

Indirect technique Straight

Straight

CIMIPARef.

5.5ø

CIMIPEURef.

4.0ø

CIMIUPU CIMIUPARef. Ref.

CIMIPEUA

IROMIEUA

Ref.

Ref.

5.0

4.0

ø

øRef. Ø Longitud Ref. Ø LongitudIROMIEU1IROMIEU

4.04.0

6 mm.9 mm.

IROMIA 5.5 9 mm.

MULTI-IM® TRANSEPITHELIAL

Page 26: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 26 |

LABORATORY ANALOG

Analog of the implant platform or transepithelial abutment.

Once the tray has been extracted from the patient's mouth with the copings, the appropriate analog must be screwed in.

The analogs of internal connection are manufactured from commercially pure titanium, while the analogs of external connection are manufactured from surgical stainless steel.

They are a faithful reproduction of the platform and connection of the implant. They are designed to withstand the placement of the prosthetic work.

INTERNA AND EXTERNA

Page 27: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 27 |

FAMILYLaboratory analog

Manufactured from surgical stainless steel. Manufactured from surgical stainless steel. Manufactured from surgical stainless steel.

Ref. Ref. Ref.RLMIEU RLMIEUA RLMIA

Straight Angled 17º Straight

Narrow

Universal

Universal Plus

Wide

Ref.

Ref. Ref.

Ref. Ref.

Ref.

Ref.

Ref.

INTERNA®

EXTERNA®

Manufactured from commercially pure titanium.

Manufactured from surgical stainless steel.

Manufactured from commercially pure titanium.

Manufactured from commercially pure titanium.

Manufactured from commercially pure titanium.

Manufactured from surgical stainless steel.

Manufactured from commercially pure titanium.

Manufactured from surgical stainless steel.

RLIE

RLMIUPU RLMIUPA

INRLIE INRLIU

RLIU

INRLIA

RLIA

MULTI-IM® TRANSEPITHELIAL

UNIT TRANSEPITHELIAL

Page 28: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 28 |

PROVISIONAL TITANIUM CYLINDER Engaging and non-engaging

Cylinder indicated for the manufacture of resin provisionals.

Manufactured from commercially pure titanium. It has different emergence profiles depending on the implant platform for which they are indicated.

They are screwed into the implant with the titanium Ti-black hexagonal or gold square screw at 35 Ncm and at 20 Ncm on the transepithelials.

INTERNA AND EXTERNA

Page 29: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 29 |

FAMILYProvisional titanium cylinder

Ref. Ref. Ref.Preparation of provisionals, in particular immediate loadCPMIPEU

Preparation of provisionals, in particular immediate loadCPMIPEUA

Preparation of provisionals, in particular immediate loadCPMIPA

Straight Angled 17º Straight

Narrow

Universal

Universal Plus

Wide

Ref.

Ref. Ref.

Ref.

Ref.

Ref.

Emergence profile Ø of 5 mm

Emergence profile Ø of 3.5 mm

Emergence profile Ø of 3.5 mm

Emergence profile Ø of 5 mm

Emergence profile Ø of 6.3 mm

Emergence profile Ø of 6.3 mm

Individual restorationsCPIE1 (engaging)

Multiple restorationsCPIE0 (non-engaging)

Individual restorationsINCPIE1 (engaging)

Multiple restorationsINCPIE0 (non-engaging)

Individual restorations INCPIU1 (engaging)

Multiple restorationsINCPIU0 (non-engaging)

Individual restorations CPIU1 (engaging)

Multiple restorationsCPIU0 (non-engaging)

Individual restorations INCPIA1 (engaging)

Multiple restorationsINCPIA0 (non-engaging)

Individual restorations CPIA1 (engaging)

Multiple restorationsCPIA0 (non-engaging)

Ref. Ref.Preparation of provisionals, in particular immediate loadCPMIUPU

Preparation of provisionals, in particular immediate loadCPMIUPA

INTERNA®

EXTERNA®

MULTI-IM® TRANSEPITHELIAL

UNIT TRANSEPITHELIAL

Page 30: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 30 |

PROVISIONAL TITANIUM BIOPILAR®

Cylinder indicated for the manufacture of resin provisionals. This range of abutments is specific for the philosophy of the BIOPILAR® profiles. The BIO concept represents an evolution of the design of prosthodontic rehabilitation, based on the modification of the biological space.

It introduces a new vision oriented towards the long-term stability of hard and soft tissues for long lasting aesthetics. It is based on a change in the morphology of the transgingival profile to ensure better vascularisation.

INDICATIONS

· In cases of aesthetic requirements in the anterior sector.

· When we wish to reduce the transgingival profile for horizontal movement in the biological space.

· In cases of limited interdental space.

ADVANTAGES:

· Increases the biological space.

· Improves the vascularisation around the abutment and, consequently, reduces gum recession.

· Favours the maintenance of bone tissue.

· Material: commercially pure titanium.

INTERNA AND EXTERNA

Page 31: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 31 |

FAMILYProvisional titanium bio-abutment

INTERNA® EXTERNA®

Emergence profile Ø of 5.0 mm Emergence profile Ø of 5.0 mm

Emergence profile Ø of 5.0 mm Emergence profile Ø of 5.0 mm

Ref. Ø Length Ref. Ø Length

Ref. Ø Length Ref. Ø Length

INCPIUB13INCPIUB14(engaging)

5.05.0

3 mm4 mm

CPIUB13CPIUB14(engaging)

5.05.0

3 mm4 mm

INCPIUB03INCPIUB04(non-engaging)

5.05.0

3 mm4 mm

CPIUB03CPIUB04(non-engaging)

5.05.0

3 mm4 mm

Universal

Universal Plus

Wide

Page 32: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 32 |

PROVISIONAL AESTHETIC CYLINDEREngaging and non-engaging

Plastic provisional cylinders (PEEK) in white, which makes them suitable for preparing provisionals in aesthetic areas. They can be loaded with acrylic materials without the need to hide the grey of the titanium.

The observations to be taken into account in the use of these components are the following:

· These parts are approved for provisional use in the mouth for periods of 6 months or less, so a more long-term

use is absolutely contraindicated.

· The drilling of these parts in the laboratory must be performed at low revolutions. Excessive overheating that could melt the plastic must be avoided.

· They are not indicated in patients with bruxism or in the posterior tooth area exposed to greater masticatory loads.

· In cases in which it is necessary to use cement on these parts, it is advisable to avoid polyurethane-based cements, as they may present problems of setting.

They are screwed into the implant with the titanium Ti-black hexagonal or gold square screw at 20 Ncm and on the transepithelials also at 20 Ncm .

INTERNA AND EXTERNA

Page 33: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 33 |

FAMILYAesthetic provisional cylinders and abutments

Narrow

Universal

Universal Plus

Wide

For screw-retained prostheses

For screw-retained prostheses

For screw-retained prostheses

For screw-retained prostheses

For screw-retained prostheses

For screw-retained prostheses

For cemented prostheses

For cemented prostheses

Ref.

Ref. Ref.

Ref.

Ref.

Ref.

INPPUP44INPPUP54

PPUP44PPUP54

Ref.

Ref.

4.05.0

4.05.0

ø

ø

Emergence profile Ø of 6.3 mm

Emergence profile Ø of 6.3 mm

Emergence profile Ø of 5 mm

Perfil de emergencia de 3,5 mm. de ø.

Perfil de emergencia de 3,5 mm. de ø.

Emergence profile Ø of 5 mm

Emergence profile Ø of 4 and 5 mmHeight of neck 4 mm

Emergence profile Ø of 4 and 5 mmHeight of neck 4 mm

Individual restorationsCPIEP1 (engaging)

Multiple restorationsCPIEP0 (non-engaging)

Individual restorationsINCPIEP1 (engaging)

Multiple restorationsINCPIEP0 (non-engaging)

Individual restorations INCPIUP1 (engaging)

Multiple restorationsINCPIUP0 (non-engaging)

Individual restorations CPIUP1 (engaging)

Multiple restorationsCPIUP0 (non-engaging)

Individual restorations INCPIAP1 (engaging)

Individual restorations CPIAP1(engaging)

Ref.Ref. Ref. Ref.Preparation of provisionals, in particular immediate loadCPMIPEUP

Preparation of provisionals, in particular immediate loadCPMIUPUP

Preparation of provisionals, in particular immediate loadCPMIUPAP

Preparation of provisionals,in particular immediate loadCPMIPAP

INTERNA®

EXTERNA®

MULTI-IM® TRANSEPITHELIALUNIT TRANSEPITHELIAL

Page 34: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 34 |

GOLD ABUTMENT POST

Enables the restoration of multiple and individual teeth. They are screwed directly into the implant and used with cemented prostheses. The impression is made directly to the implant (indirect technique).

Due to the precious alloy from which they are manufactured, the gold abutments can be ceramised with conventional feldspar ceramic, and thus porcelain margins can be created. (CET 25-500ºC: 14.6 x 10-6 K-1; 25-600ºC: 14.9 x 10-6 K-1). Fusion interval: 1020-1155ºC.

They are screwed into the implant with the Ti-black screw or the gold square screw at 35 Ncm.

INDICATIONS

· Multiple and single restorations, with high aesthetic requirements without serious angle problems (0º-15º).

· Material: Au precious alloy + metals from the group Pt 97.5%.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 35: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 35 |

FAMILYGold abutment post

Narrow

Universal

Universal Plus

Wide

Anatomical gold abutment post

INTERNA® EXTERNA®

Ref. Ø LengthRef. Ø Length

Ref. Ø LengthRef. Ø Length

Ref. Ø Length

PPAOE42 PPAOE44

3.7/4.23.7/4.2

2 mm.4 mm.

INPPOU42INPPOU44

4.14.1

2 mm.4 mm.

PPOU42 4.0 2 mm.INPPOU52INPPOU54

5.05.0

2 mm.4 mm.

PPOU52 5.0 2 mm.

Page 36: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 36 |

TITANIUM ABUTMENT POST Straight and angled

Enables the restoration of multiple and individual teeth. They are screwed directly into the implant and used with cemented prostheses. The impression is made directly to the implant (indirect technique).

They are screwed into the implant with the Ti-black screw or the gold square screw at 35 Ncm.

INDICATIONS

· Straight titanium abutment posts: They are indicated for multiple and single restorations without significant angle problems (between 0º and 15º).

· Angled titanium abutment posts 15º: They are indicated for multiple and single restorations without significant angle problems (between 15º and 25º).

· In cases juxta-gingival implants, they can be micromilled to the limit (leaving a minimum margin of metal on the vestibular side).

· Material: commercially pure titanium.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 37: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 37 |

FAMILYTitanium abutment post

Narrow

Universal

Universal Plus

Wide

INTERNA®

EXTERNA®

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Longitud

Ref. Ø Longitud

Ref. Ø Length

Ref. Ø Length

Ref. Ø Longitud

Ref. Ø Length

Ref. Ø Longitud

PPATEA32 PPATEA34

2 mm.4 mm.

Straight

Straight Straight

Angled 15º

Angled 15º Angled 15º

Angled 15º

Anatomic angled 15º

Straight

Angled 15º

3.7/4.23.7/4.2

INPPTUA52 5.0 2 mmINPPTUA54 5.0 4 mm INPPTAA52 5.5 2 mm

INPPTAA54 5.5 4 mm

INPPTUA42 4.3/5.0 2 mmINPPTUA44 4.3/5.0 4 mm

INPPTU42 4.1 2 mmINPPTU44 4.1 4 mm

INPPTU52 5.0 2 mmINPPTU53 5.0 3 mmINPPTU54 5.0 4 mmINPPTU56 5.0 6 mm

INPPTU62 6.0 2 mmINPPTU63 6.0 3 mmINPPTU64 6.0 4 mm

PPTU42 4.1 2 mmPPTU44 4.1 4 mm

PPTU52 5.0 2 mmPPTU53 5.0 3 mmPPTU54 5.0 4 mmPPTU56 5.0 6 mm

PPTU62 6.0 2 mmPPTU63 6.0 3 mmPPTU64 6.0 4 mm

INPPTA52 5.5 2 mmINPPTA54 5.5 4 mmINPPTA56 5.5 6 mm

INPPTA62 6.5 2 mmINPPTA64 6.5 4 mmINPPTA66 6.5 6 mm

INPPTA74 7.5 4 mm

PPTUA52 5.0 2 mmPPTUA53 5.0 3 mmPPTUA54 5.0 4 mm.

PPTA52 5.5 2 mmPPTA54 5.5 4 mmPPTA56 5.5 6 mm

PPTA62 6.5 2 mmPPTA64 6.5 4 mmPPTA66 6.5 6 mm

PPTA74 7.5 4 mm

PPTAA52 5.5 2 mmPPTAA54 5.5 4 mm

With a surface treatment Ti golden.

With a surface treatment Ti golden.

Page 38: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 38 |

TITANIUM BIOPILAR® Straight and angled

Enables the restoration of multiple and individual teeth. They are screwed directly into the implant with the square gold screw or the Ti-black screw at 35 Ncm and used with cemented prostheses.

This range of abutments is specific for the philosophy of the BIOPILAR® profiles. The BIO concept represents an evolu-tion of the design of prosthodontic rehabilitation, based on the modification of the biological space. It introduces a new vision oriented towards the long-term stability of hard and soft tissues for long lasting aesthetics. It is based on a change in the morphology of the transgingival profile to ensure better vascularisation.

INDICATIONS

· In cases of aesthetic requirements in the anterior sector.

· When we wish to reduce the transgingival profile for horizontal movement in the biological space.

· In cases of limited interdental space.

ADVANTAGES:

· Increases the biological space.

· Improves the vascularisation around the abutment and, consequently, reduces gum recession.

· Favours the maintenance of bone tissue.

· Material: Commercial pure titanium with a Ti-golden surface treatment.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 39: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 39 |

FAMILYTitanium bio-abutment

Narrow

Universal

Universal Plus

Straight

Straight

Straight

Straight

Angled 15º

Angled 15º

Angled 15º

Angled 15º

PPATEB43 4.2 3 mmPPATEB44 4.2 4 mmPPATEB45 4.2 5 mm

INPPTEB43 4,.2 3 mm.INPPTEB44 4.2 4 mm. INPPTUB53 5.0 3 mm

INPPTUB54 5.0 4 mmINPPTUB55 5.0 5 mm

PPTUB53 5.0 3 mmPPTUB54 5.0 4 mmPPTUB55 5.0 5 mm

PPTEAB33 3.7/4.2 3 mmPPTEAB34 3.7/4.2 4 mmPPTEAB35 3.7/4.2 5 mm

INPPTEAB43 3.75/4.2 3 mm.INPPTEAB44 3.75/4.2 4 mm.INPPTEAB45 3.75/4.2 5 mm.

INPPTUAB53 5.0 3 mmINPPTUAB54 5.0 4 mmINPPTUAB55 5.0 5 mm

PPTUAB53 5.0 3 mmPPTUAB54 5.0 4 mmPPTUAB55 5.0 5 mm

Ref. Ø Length

Ref. Ø LengthRef. Ø Length

Ref. Ø Length

Ref. Ø Length

Ref. Ø Length Ref. Ø Length

Ref. Ø Length

Straight bio-abutments: They are indicated for multiple and single restorations without significant angle problems (between 0º and 15º).

Angled bio-abutments 15º: They are indicated for multiple and single restorations without significant angle problems (between 15º and 25º).

INTERNA®

EXTERNA®

Page 40: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 40 |

CERAMISABLE ABUTMENT POST CERAMIC-ON®

These enable the restoration of multiple and individual teeth. They are screwed directly into the implant and used with cemented prostheses. The impression is made directly to the implant (indirect technique).

They come in gold and titanium for Universal platform (internal and external connections) and in gold for the Wide platform (external connection).

They are screwed into the implant with the square gold screw or the Ti-black screw at 35 Ncm. They do not require the use of any other component.

INDICATIONS

· Multiple and single restorations When the height of the tissues is 1 mm or greater, it is possible to make angled

ceramic abutments. Crowns with a ceramic shoulder or fully ceramic crowns can be cemented onto them.

· Designed to add ceramic for titanium in the titanium abutments and conventional ceramic in the gold abutments.

(CET 25-500ºC: 14.6 x 10-6 K-1; 25-600ºC: 14.9 x 10-6 K-1).

· Fusion interval: 1020-1155ºC.

· Manufactured: The titanium version, from commercially pure Ti. The gold version, from a precious alloy (Au + metals from the group Pt 97.5%).

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 41: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 41 |

FAMILYCERAMIC-ON®

Gold

Titanium

INTERNA®

INPPCOU 5.0 1 mm

INPPCTU 5.0 1 mm

Ref. Ø Length

Ref. Ø Length

N.B.The union of the ceramic to the gold abutment exceeds that of titanium, so BTI advocates the use of gold abutments. These posts are supplied without ceramising.

Universal

Universal Plus

Page 42: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 42 |

AESTHETIC ABUTMENT POSTEngaging and non-engaging

Aesthetic abutments for direct to implant prostheses, with a BIO Profile of for long-term maintenance of the gingival mucous membranes.

Available in five heights: 0,1,2,3,4 for Universal Platform Interna Connection; and four heights: 0,2,3,4 for all the rest plata-forms Interna and Externa connection. Manufactured from commercial pure titanium with a Ti-golden surface treatment.

Non-engaging version: Suitable for multiple prosthesis screwed into the implant.Engaging version: Suitable for single prosthesis (screwed and cemented) and multiple cemented prosthesis.

Highly versatile, they can be used with or without a casting sleeve, for the manufacture of conventional prostheses and CAD/CAM systems.

The casting sleeves are manufactured from ertacetal. When working with no sleeve, the aesthetic abutments are used as machined bases for cemented prostheses on which the Zr, e-max, Ti, Cr-Co and resin sleeves can be modelled. When working with a sleeve, there are prepared screw retained and cemented conventional prostheses (casting and ceramic injection).

They are screwed into the implant with the square gold screw or the Ti-black screw at 35 Ncm.

+ More information on the aesthetic abutment post in the brochure “Aesthetic abutments with BIO profile”.

INTERNA AND EXTERNA

Page 43: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 43 |

FAMILYAesthetic abutment post

Ti-golden

Ti-golden

Ti-golden

Ti-golden Ti-golden

Ti-golden

Ref.

Ref.

ø

ø

Length

Length Ref.

Ref.

Ref.ø

ø

øLength

Length

Length

Ref. ø Length Ref. ø Length

CPUTZ CPATZRef. Ref.

PTTZ0 3.5 0 mm.

PTTZ2 3.5 2 mm.PTTZ3 3.5 3 mm.PTTZ4 3.5 4 mm.

INPETZ0 3.5 0 mm.

INPETZ1 3.5 1 mm.INPETZ2 3.5 2 mm.INPETZ3 3.5 3 mm.INPETZ4 3.5 4 mm.

INPUTZ0 4.1 0 mm.

INPUTZ1 4.1 1 mm.INPUTZ2 4.1 2 mm.INPUTZ3 4.1 3 mm.INPUTZ4 4.1 4 mm.

INPURTZ0 4.1 0 mm.

INPURTZ1 4.1 1 mm.INPURTZ2 4.1 2 mm.INPURTZ3 4.1 3 mm.INPURTZ4 4.1 4 mm.

PUTZ0 4.1 0 mm.

PUTZ2 4.1 2 mm.PUTZ3 4.1 3 mm.PUTZ4 4.1 4 mm.

PATZ0 5.5 0 mm.

PATZ2 5.5 2 mm.PATZ3 5.5 3 mm.PATZ4 5.5 4 mm.

INPATZ0 5.5 0 mm.

INPATZ2 5.5 2 mm.INPATZ3 5.5 3 mm.INPATZ4 5.5 4 mm.

Universal

ENGAGING

NON-ENGAGING

Wide

CASTING SLEEVE

INTERNA®

EXTERNA®

Narrow

Universal

Universal Plus

Wide

CPETZRef.

Narrow

Page 44: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 44 |

UCLA GOLD ABUTMENTEngaging and non-engaging

Gold cylinder, machined, used as an alternative in the construction of the conventional UCLA abutment. The engaging one is used for the construction of individual teeth (screw-retained) or stumps (cemented). The non-engaging one is used in cases of multiple screw-retained restorations. The impression is made directly to the implant (indirect tech-nique).

They are screwed into the implant with the square gold screw or the Ti-black screw at 35 Ncm.

INDICATIONS

· Multiple and single restorations It also solves problems of angle and customisation of the emergence profile, as angled abutments can be custom made. They are cast-on with precious alloys for ceramic, for subsequent ceramisa-

tion, or with gold for manufacturing stumps. (CET 25-500ºC: 11.9x10-6 K-1; 25-600ºC: 12.2x10-6 K-1).

· Material: Alloy with a high gold content and a high melting point (1400º C).

· Consisting of two parts: Gold cylinder and casting chimney.

· BTI strongly recommends that, in cases of multiple screw-retained prosthesis, the abutment Multi-Im® is used

instead of this component.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 45: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 45 |

FAMILYUCLA gold abutment

Ref.

Ref. Ref.

Ref. Ref.PUOE1 (engaging)PUOE0 (non-engaging)

INPUOU1 (engaging)INPUOU0 (non-engaging)

PUOU1 (engaging)PUOU0 (non-engaging)

PUOA1 (engaging)PUOA0 (non-engaging)

INPUOA1 (engaging)INPUOA0 (non-engaging)

Emergence profile Ø of 3.5 mm

Emergence profile Ø of 4.1 mm

Emergence profile Ø of 4.5 mm

Emergence profile Ø of 5.5 mm.

Emergence profile Ø of 5.5 mm

INTERNA®

EXTERNA®

Narrow

Universal

Universal Plus

Wide

Page 46: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 46 |

CASTABLE ABUTMENTEngaging and non-engaging

Manufactured from casting plastic, the engaging one is used for the construction of individual teeth (screw-retained) or stumps (cemented), while the non-engaging one is used in cases of multiple screw-retained restorations.

The impression is made directly to the implant (indirect technique).

They are screwed into the implant with the square gold screw or the Ti-black screw at 35 Ncm.

INDICATIONS

· Multiple and single restorations It also solves problems of angle and customisation of the emergence, as angled abutments can be custom made.

· They are cast with precious alloys for ceramic or with gold for manufacturing stumps.

· Lower quality alloys must not be used as the fit will be deficient and there may be problems of subsequent loosening of the abutments.

BTI strongly recommends that, in cases of multiple screw-retained prosthesis, the abutment Multi-Im® is used instead of this component.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 47: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 47 |

FAMILYCastable abutment

Narrow

Universal

Universal Plus

Wide

Ref.

Ref. Ref.

Ref. Ref.PUCE1 (engaging) PUCE0 (non-engaging)

INPUCU1 (engaging)INPUCU0 (non-engaging)

PUCU1 (engaging)PUCU0 (non-engaging)

PUCA1 (engaging)PUCA0 (non-engaging)

INPUCA0 (non-engaging)

Emergence profile Ø of 3.5 mm

Emergence profile Ø of 4.5 mm

Emergence profile Ø of 5.5 mm

Emergence profile Ø of 5.5 mm

Emergence profile Ø of 5.5 mm

INTERNA®

EXTERNA®

Ref.INPUCE1 (engaging)INPUCE0 (non-engaging)

Emergence profile Ø of 3.5 mm

Page 48: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 48 |

UNIT TRANSEPITHELIALStraight

Engaging titanium transepithelial made up of two components: sleeve and retaining screw. Ti golden surface treat-ment in the cylinder and Ti-black in the screw.

It is available for the Universal and Wide platform Interna connection and universal platform Externa connection. Con-nection with the implant through the corresponding tetra-lobed figure. At the top has a square, with no sharp edges, into which the rest of the components fit.

It is screwed into the implant with the disposable plastic screwdriver and the definitive torque is appliedwith the tapered-standard torque wrench tip PTCE16 and the torque wrench LLMTP at 35 Ncm.

The Unit Transepithelial for wide platform Interna connection has a specific torque wrench tip PTUA.

INDICATIONSThis is the appropriate component for immediate loading of screw retained single unit restoration. It asures the Hermetic Seal at the interface with the implant and the preservation of biological seal by means of hemides-mosomes; enables finishing the works in CAD/CAM or using the conventional aesthetic abutments.

INTERNA

+ More information on the UNIT transepithelial on the website: www.bti-biotechnologyinstitute.es

Re-use and/or re-sterilisation of these single-use products may cause risk of infection and/or cross contamination.

Page 49: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 49 |

FAMILYUNIT Transepithelial

INTMIUPU20INTMIUPU30INTMIUPU40INTMIUPU50

Ref.4,14,14,14,1

ø2 mm.3 mm.4 mm.5 mm.

Length

Emergence profile Ø of 4.1 mmProsthesis diameter of 4.1 mm

INTERNA®

INTMIUPE20INTMIUPE30INTMIUPE40

Ref.3,53,53,5

ø2 mm.3 mm.4 mm.

Length

Emergence profile Ø of 3.5 mmProsthesis diameter of 4.1 mm

Narrow

Universal

Universal Plus

EXTERNA®

TMIUPU30TMIUPU40

Ref.4,14,1

ø3 mm.4 mm.

Length

Emergence profile Ø of 4.1 mmProsthesis diameter of 4.1 mm

INTMIUPA20INTMIUPA30INTMIUPA40

Ref.5,55,55,5

ø2 mm.3 mm.4 mm.

Length

Emergence profile Ø of 5.5 mmProsthesis diameter of 5.5 mm

Straight

TPMIUPARef.

5.5ø

Straight

TPMIUPURef.

4,0ø

PROTECTIVE CAPS

Page 50: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 50 |

Multi-Im® TRANSEPITHELIAL Straight and angled

Titanium transepithelial made up of two components: sleeve and retaining screw. Ti golden surface treatment in the cylinder and Ti-black in the screw.

The straight one is screwed into the implant with the disposable plastic screwdriver and the definitive torque is ap-plied with the tapered-standard torque wrench tip PTCE16 and the torque wrench LLMTP at 35 Ncm.

In the case of the angled 17º, the transporter is metallic. To apply the torque, the tip PTHS22 shall be used with wrench LLMTP at 35 Ncm. This angle of 17º between the prosthetic and surgical axis will help us to correct non-parallel cases for inclined implants, with greater ease in the construction of the prosthesis. The prosthetic components of these ele-ments are specially designed for this. The impression is made with the specific impression coping.

INDICATIONS

For multiple screw-retained restorations. This is the abutment to choose for screw-retained immediate load in multiple restorations and for manufacturing bars on overdentures. It enables the restoration to emerge even at 0.5 mm above the implant, in addition its low cone height enables us to resolve divergences between implants.They are sold sterile.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

+ More information on the Multi-Im® transepithelial on the website: www.bti-biotechnologyinstitute.es

Re-use and/or re-sterilisation of these single-use products may cause risk of infection and/or cross contamination.

INTERNA AND EXTERNA

Page 51: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 51 |

FAMILYMulti-Im® transepithelial abutment

Angled 17º

Straight (Ti Golden)

Straight (Ti Golden)

Straight (Ti Golden)

Straight (Ti Golden)

Angled 17º

Angled 17º

INTMIPU05INTMIPU10INTMIPU20INTMIPU30INTMIPU40INTMIPU50

Ref.4.14.14.14.14.14.1

ø0,5 mm.

1 mm.2 mm.3 mm.4 mm.5 mm.

Length

TMIPU10TMIPU20TMIPU30TMIPU40

Ref.4.14.14.14.1

ø1 mm.2 mm.3 mm.4 mm.

Length

INTMIPA10INTMIPA20INTMIPA30INTMIPA40

Ref.5.55.55.55.5

ø1 mm.2 mm.3 mm.4 mm.

Length

TMIPA15TMIPA20TMIPA30TMIPA40

Ref.5.55.55.55.5

ø1,5 mm.

2 mm.3 mm.4 mm.

Length

TMIPEA20TMIPEA30TMIPEA40

Ref.3.53.53.5

ø2 mm.3 mm.4 mm.

Length

INTMIPUA15 INTMIPUA20 INTMIPUA30 INTMIPUA40 INTMIPUA50

INTMIPUB15 INTMIPUB20 INTMIPUB30 INTMIPUB40 INTMIPUB50

Ref.4.14.14.14.14.1

4.14.14.14.14.1

ø1,5 mm.

2 mm.3 mm.4 mm.5 mm.

1,5 mm.2 mm.3 mm.4 mm.5 mm.

Length

TMIPUA15 TMIPUA20 TMIPUA30 TMIPUA40 TMIPUA50

Ref.4.14.14.14.14.1

ø1,5 mm.

2 mm.3 mm.4 mm.5 mm.

Length

Emergence profile Ø of 4.1 mmProsthesis diameter of 4.1 mm

Emergence profile Ø of 4.1 mmProsthesis diameter of 4.1 mm

Emergence profile Ø of 3.5 mmProsthesis diameter of 5.0 mm

Emergence profile Ø of 4.1 mmProsthesis diameter of 5.0 mm

Emergence profile Ø of 5.5 mmProsthesis diameter of 5.5 mm

Emergence profile Ø of 5.5 mmProsthesis diameter of 5.5 mm

Emergence profile Ø of 4.1 mmProsthesis diameter of 5.0 mm

INTERNA®

EXTERNA®

Straight (Ti Golden)

Straight (Ti Golden)

TMIPE15TMIPE20TMIPE30TMIPE40

Ref.3.53.53.53.5

ø1,5 mm.

2 mm.3 mm.4 mm.

Length

INTMIPE10INTMIPE20INTMIPE30INTMIPE40INTMIPE50

Ref.3.53.53.53.53.5

ø1 mm.2 mm.3 mm.4 mm.5 mm.

Length

Emergence profile Ø of 3.5 mmProsthesis diameter of 4.1 mm

Emergence profile Ø of 3.5 mmProsthesis diameter of 4.1 mm

Narrow

Universal

Universal Plus

Wide

Page 52: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 52 |

TRANSEPITHELIALSExpanded

Expanded transepithelials, for Interna and Externa connections.

These new products make the transfer from the Universal platform (diameter 4.1 mm in the implant) to the Wide plat-form (diameter 5.5 mm prosthetic structure).

They maintain the two-part structure (sleeve and screw), and the surface with Ti Golden treatment and Ti Black screw.

The Multi-Im® transepithelials Interna Connection are available in 4 heights: 2, 3, 4 and 5. The transepithelial Unit In-terna connection and Multi-Im® Externa connection are available in 3 heights: 2, 3 and 4 mm.

Insertion into the implant at 35 Ncm torque.

INDICATIONS

They are indicated for rear areas of the mandible which need a wider prosthetic emergence than that offered by a Universal platform.

They facilitate the stability of the soft tissues, in rear areas of the jaw, in the second surgery or in cases of immediate load. Having positioned an implant from the Universal platform, they distribute the biomechanical load better in these rear areas of the mandible.

INTERNA AND EXTERNA

Re-use and/or re-sterilisation of these single-use products may cause risk of infection and/or cross contamination.

Page 53: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 53 |

FAMILYExpanded Transepithelial

Universal

Universal Plus

Wide

INTERNA® AND EXTERNA®

All the caps are screwed onto the transepithelials. They are used from the placement of the transepithelial until the fitting of the definitive or provisional prosthesis, to prevent the gum growing over the transepithelial and protecting the tongue from friction. The head of the cap has a hexagonal insertion that enables it to be transported to its position easily. The rec-ommended tightening torque is 10 Ncm.

Material: commercially pure titanium.

N.B.These transepithelials are

screw-retained into implants of

the Universal platform and are

restored with prosthetic attach-

ments from the Wide platform.

INTMIPUEX20INTMIPUEX30INTMIPUEX40INTMIPUEX50

Ref.4.14.14.14.1

ø2 mm3 mm4 mm5 mm

LengthTMIPUEX20TMIPUEX30TMIPUEX40

Ref.4.14.14.1

ø2 mm3 mm4 mm

Length

INTERNA® MULTI-IM EXTERNA® MULTI-IM

Emergence profile Ø of 4.1 mmProsthesis diameter of 5.5 mm

Emergence profile Ø of 4.1 mmProsthesis diameter of 5.5 mm

INTMIUPUEX20INTMIUPUEX30INTMIUPUEX40

Ref.4,14,14,1

ø2 mm.3 mm.4 mm.

4 mm.

3 mm.

Length

Length

Emergence profile Ø of 4.1 mmProsthesis diameter of 5.5 mm

TRANSEPITHELIAL UNIT

PROTECTIVE CAPSMulti-Im® transepithelial abutment

Straight Angled 17º Straight

TPMIARef.

5.5ø

TPMIEU

TPMIEU1

Ref.4.0

4.0

øTPMIEUARef.

5.0ø

Narrow

Universal

Universal Plus

Wide

Page 54: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 54 |

TOOLS FOR THE LABORATORY

Tools for polishing, made for Multi-Im transepithelial Narrow and Universal platforms and for UNIT Transepithelial Narrow and Universal platform.

These pieces are necessary for the protection of the prosthetic structures in the laboratory.

INTERNA Y EXTERNA

Page 55: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 55 |

FAMILYTools for the laboratory

Narrow

Universal

Universal Plus

Ref.

UPMIUPU

MULTI-IM®

Ref.

UPMIEU

UNIT TRANSEPITHELIAL

Page 56: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 56 |

ARTICULATED BARS FOR STRAIGHT Multi-Im®

Suitable for provisional prosthetic structures screw-retained on Multi-Im® abutments. They are titanium cylinders with lateral spheres, that mesh with the articulated bars to form the internal structure of the prosthesis.

ADVANTAGES

· Ease and speed in the completion of the work.

· More robust that a classic provisional structure.

INTERNA AND EXTERNA

Page 57: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 57 |

FAMILYArticulated bars for straight Multi-Im®

SPECIFICATIONS

The measurement of the maximum overhang permitted with these parts depends on the measurements of the horizontal arm of the cylinder.

The maximum distance permitted between implants, to be able to work with this system of bars, shall be limited to the maximum length of the horizontal bar.

4 mm

6.3 mm

di-i= 20 mm

17 mm

Narrow

Universal

Universal Plus

MULTI-IM®

Ref.BAP3

Ref.

Ref.

Ref.

Ref.

Ref.

Ref.

BAP1

BAPA1

BAP2B

BAPA2B

BAP2A

BAPA2A

Top view

Top view

Top view

Top view

NOTE: The spheres may be cut, if they will not be used in the structure, so they do not interfere with adjacent teeth.

NOTE: The spheres may be cut, if they will not be used in the structure, so they do not interfere with adjacent teeth.

NOTE: The length of this bar can be short-ened depending on the distance between implants.

Wide

Page 58: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 58 |

CYLINDER FOR STRAIGHT AND ANGLED Multi-Im®

GOLD CYLINDERS

They are used with the Multi-Im® transepithelial for the preparation of the final prosthesis. Their bevelled design enables a better union between the porcelain and the gold cylinder. We recommend using an alloy with a high gold content for cast-on (CET 25-500ºC:11.9x10-6 K-1; 25-600ºC: 12.2x10-6 K-1).

They incorporate a casting chimney, to facilitate the wax-up work in the laboratory. The parts are non engaging. If needed, the casting sleeve can be separated from the gold body by traction.Material: Gold alloy (1400ºC).

CASTING CYLINDERS

Used for the manufacture of the final restoration on Multi-Im® transepithelials, making a direct wax-up of onto the casting cylinder. Material: casting plastic.

Screw-retained onto the abutment with a TTMIR screw at 20 Ncm.

INTERNA AND EXTERNA

Page 59: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 59 |

FAMILYCylinders for straight and angled Multi-Im®

MULTI-IM®

Ref. Ref.

Ref.Ref. Ref.

Ref.

Ref.

COMIPEU CZMIPEU

CZMIPACOMIPA CCMIPA

CCMIPEU

CCMIPEUA

Straight (gold)

Straight (titanium for zirconium)

Straight (titanium for zirconium)

Straight (gold)

Straight (casting)

Straight (casting)

Angled 17º (casting)

Narrow

Universal

Universal Plus

Wide

Page 60: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 60 |

CYLINDERS FOR UNIT TRANSEPITHELIAL

AESTHETIC ABUTMENTS

Solution for the definitve prosthetic restoration on the Unit Transepithelials.

Highly versatile, the aesthetic abutments can be used with or without a casting sleeve, for the manufacture of conven-tional prostheses and CAD/CAM systems.

They are screwed onto the transepithelials with the TTMIR screw at 20 Ncm.

Attention! When restoring on Unit Transepithelial Wide Plataform it is necessary to use a different screw TTMIUPA (20 Ncm).

INTERNA AND EXTERNA

Page 61: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 61 |

FAMILYCylinders for UNIT

Ref. Ref.

Ref.

Ref.

Ref.

Ref.

PTZMIUPU PTZMIUPA

CPTZMIUPA

PUCMIUPA

CPTZMIUPU

PUCMIUPU

Aesthetic abutment Aesthetic abutment

Casting sleeve

Casting sleeve

Casting sleeve

Casting sleeve

UNIT TRANSEPITHELIAL

Narrow

Universal

Universal Plus

Wide

Page 62: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 62 |

LOCATOR ABUTMENT

Abutment for overdentures, in one single piece that must be screw-retained into the implant at a torque of 30 Ncm.

We will select the abutment that is exactly at the same height as the tissue or the next size up. This size will enable the 1.5 mm of the fixing head to emerge over the level of the gum that surrounds the implant.

PROPERTIES

· Auto-aligning, as they provide easy positioning and correct seating of the patient's overdentures; in addition they eliminate additional wear and the loss of bonding due to incorrect seating.

· Angle corrections of up to 40º, in divergent implants, using the same abutment, therefore it is not necessary to place angled pillars.

· The lowest vertical height of the market, an advantage especially when the interocclusal space is limited. The total height of fixing is 2.5 mm for an Interna connection implant.

LOCATOR MAIN TOOL (Ref. HPL)

There are three parts with the following uses: screwdriver for the abutment, to provide the torque with a large hexa-gon tip, remove the processing male and insert the final retention male.

INTERNA AND EXTERNA

Page 63: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 63 |

FAMILY AND COMPONENTSLocator

COMPONENTS

Ref. Height

PTTL15 15 mmPTTL21 21 mm

Ref. Retention Angle

MLRA extra light 0-10º

MLRR light 0-10º

MLST strong 0-10º

MLAR extra light 10-20º

MLAN light 10-20º

MLAV strong 10-20º

MLAG without retention 10-20º

Ref.

GMAL

Ref. Height

PTL23 23 mmPTL29 29 mm

Ref.

JML2 (2 Units)JML10 (10 Units)

Ref.

RLL4

Ref.

AEL

Ref.

IDL

Ref.

CIL

Ref.

CRHL

Torque tip

Replacement males (4 Units)

Angle measurement guide

Set of replacement males

Female analogue (4 units)

Screwdriver tip Spacing ring

Direction indicator

Impression coping (4 units)

Retention cylinder

Manufactured from aluminium.A male in the polyethylene interior.

Analog with Ø of 5.5 mm, manufactured in aluminium.

INTERNA® EXTERNA®

Ref. Length

PLIU10 1 mm.PLIU20 2 mm.PLIU30 3 mm.PLIU40 4 mm.30 Ncm.

Ref. Length

PLIE10 1 mm.PLIE20 2 mm.PLIE30 3 mm.PLIE40 4 mm.30 Ncm.

Ref. Length

PLEU10 1 mm.PLEU20 2 mm.PLEU30 3 mm.PLEU40 4 mm.30 Ncm.

Ref. Length

PLT10 1 mm.PLT20 2 mm.PLT30 3 mm.PLT40 4 mm.30 Ncm.

Narrow

Universal

Universal Plus

Page 64: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 64 |

DALBO® TRANSEPITHELIAL

Abutment with two parts, designed to stabilise and retain the partial or complete prosthesis.

Screw directly into the implant with the handle MDPT and the tip PTDO at a torque of 20 Ncm. It needs a minimum intermaxillar distance (available in different heights).

The impression is made directly to the implant.

INDICATIONS

· For partial or complete removable prostheses, with a maximum divergence of 10.

· It enables the restoration to emerge even at only 2 mm over the implant.

· Material: commercially pure titanium.

* This component for the Universal and Universal Plus platforms can also be used in Wide Platform Implants (Interna®) as long as they are placed juxta- or subcrestally, to improve the biological space.

INTERNA AND EXTERNA

Page 65: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 65 |

FAMILY AND COMPONENTSDALBO®

INTERNA®

COMPONENTS

EXTERNA®

Ref. LengthINMTD2 2 mmINMTD3 3 mmINMTD4 4 mm20 Ncm

Ref. Length

MTDT3 3 mmMTDT4 4 mm20 Ncm

Ref.

HTDS (standard)

HTDP (plus

Ref.

DHTDP (plus)

Ref.

AHTDS (standard)

Ref.

DHTDS (standard)

Ref. Length

MTD2 2 mmMTD3 3 mm

MTD4 4 mm 20 Ncm

Dalbo® females

Activator and deactivatorfemale plus

Female activator standard

Female deactivator standard

TINY®

Narrow

Universal

Universal Plus

Wide

Page 66: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 66 |

TITANMAGNETICS ABUTMENTS

The Titanmagnetics abutments are retention elements for overdentures.

The system consists of two magnets:

· The first is screw-retained into the implant and is presented for Tiny® implants and for the Universal platform, for both Interna and Externa connections.

· The second is incorporated onto the prosthesis.

In addition it has a position hose, which is placed on the screw-retained magnet and this enables the second magnet to be seated perfectly upon it, accurately indicating where the prosthesis must be placed.

It also works as the insert for the transport and application of torque to the magnet that is fixed to the implant. This maximum recommended torque is 20 Ncm.

ADVANTAGES

· The fixing with magnets is dynamic and simple for the patient to put in and remove; especially for much older patients, thus facilitating hygiene.

· It is indicated for solutions for basic and economical prosthetic work.

INTERNA AND EXTERNA

Page 67: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 67 |

FAMILY AND COMPONENTSTITANMAGNETICS ABUTMENTS

INTERNA®

X-LINE COMPONENTS

EXTERNA®

Ref.

TIXL-S265

Ref.

TIXL-MPS

Ref.

TIXL-LLT

Overdenture magnet Position hose Torque wrench insert

TINY®

TIXL-4838ITRef.

4.8ø

3.8 mmLength

TIXL-4835IURef.

4.8ø

3.5 mmLength

TIXL-4835EUTIXL-4850EU

Ref.4.84.8

ø3.5 mm

5 mm

Length

Narrow

Universal

Universal Plus

Wide

Page 68: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 68 |

SCREWS

SCREWS

in gold: These are manufactured from a precious alloy coated with a layer of pure gold of 4 µm.

In titanium, Ti-black: These are manufactured from commercially pure titanium, with a specific surface treatment.

Used for the fixation of the provisional and definitive prostheses at 35 Ncm. The gold screws use a square screwdriver and the titanium use a hexagonal one.

SMALL-HEADED SCREWS

Manufactured from Ti-black, direct-to-implant or on a transepithelial, they have a smaller head to facilitate entry into CAM machined structures with a angle of up to 15º.

Both, the direct to implant and on transepithelial are tightened at 20 Ncm.

INTERNA AND EXTERNA

Page 69: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 69 |

NEW TI-BLACK SURFACE TREATMENT Screws

· Greater preload for the same torque.· Possibility of the screws coming loose reduced to a minimum.· Preload similar to gold, reducing the cost.· The lifetime of the screw is extended, as it is more resistant to fatigue.

The number of cycles of stress and fluctuating deformation that this material can withstand is much higher than that of conventional titanium and is comparable with gold.

These screws incorporate a new tungsten carbide surface treatment that de-creases the friction coefficient and improves the glide, which gives them similar properties to gold in terms of preload and resistance to fatigue.

ADVANTAGES

BIOMECHANICAL STUDY

TI-BLACK SCREWS

Ti Ti-black Gold

PRELOAD WITH A TORQUE OF 35Ncm

0

100

200

300

400

500

600

700

800

900

800

700

600

500

400

300

200

100

0

Tightening 1 Tightening 2 Tightening 3 Tightening 4 Tightening 5

Page 70: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 70 |

FAMILYDirect-to-implant screws

INTERNA® EXTERNA®

Ref.

INTOOC 35 Ncm

Ref.

INTTUH 35 Ncm

Ref.

INTTUHR 20 Ncm

Ref.

TTUHR 20 Ncm

Ref.

INTTUH3020 Ncm

Ref.

INTEIU16 (short) INTEIU (long)

Ref.

TTUH3020 Ncm

Ref.

TEIU15 (short) TEIT (long)

Ref.

TOTC 35 Ncm

Ref.

TTTH35 Ncm

Ref.

TTTHR 20 Ncm

Ref.

TTTH3020 Ncm

Ref.

TEIU15 (short) TEIT (long)

Ref.

TOOC 35 Ncm

Ref.

TTUH35 Ncm

TINY®

Gold (square) Gold (square) Gold (square)

Ti-black (hexagonal)

Ti-black (hexagonal)

For wax-up

Ti-black (hexagonal)

For wax-up

Ti-black (hexagonal)

For wax-up

Ti-black (hexagonal) Ti-black (hexagonal)

Ti-black small-headed(hexagonal)

Ti-black small-headed(hexagonal)

Ti-black small-headed(hexagonal)

Angles from 15 to 30º

Angles from 0 to 15º Angles from 0 to 15º

Angles from 15 to 30º

Angles from 0 to 15º

Angles from 15 to 30º

NOTE: Hexagon only compatible with PTHB16-22-28-34

NOTE: Hexagon only compatible with PTHB16-22-28-34

NOTE: Hexagon only compatible with PTHB16-22-28-34

Narrow

Universal

Universal Plus

Wide

Page 71: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 71 |

FAMILYTransepithelial screws and others

FOR LABORATORY

Ref.

INTTLH (hexagonal)

Ref.

TTLH (hexagonal)

Ref.

TCITS10 Ncm

Ref.

TCISC10 Ncm

Ref.

TCIPT10 Ncm

For laboratory (5 units)

For laboratory (5 units)

Healing micro-screw(headless)

Healing micro-screw(headless)

Healing screw(optional)

TINY® EXTERNA®

OTHER SCREWS

Narrow

Universal

Universal Plus

Wide

TRANSEPITHELIAS

Ti-black small-headed(hexagonal)

Ti-blackTi-black 30º (hexagonal)

Ref. Length

TEMIR 15 mm.

(small diameter)

Ref.

TTMIR20 Ncm.

Ref.

TTMIUPA20 Ncm.

Ref.

TTMI3020 Ncm.

For wax-up

NOTE: Hexagon only compatible with PTHB16-22-28-34

MULTI-IM®

UNIT

MULTI-IM®

MULTI-IM®

UNIT

UNIT

Page 72: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 72 |

INSTRUMENTS FOR SURGERY

This chapter presents all the necessary devices for the insertion of an im-plant, from the preparation of the alveolus, with the drills and the platform positioners, to the elements for securing the implant in the site using suit-able tools to transmit the final torque.

BTI has different surgical kit boxes that gather together the instruments for the implant you wish to insert.

Women who are pregnant or breastfeeding: There are no additional precautions other than those generally contemplated in techniques of oral implantology.

Page 73: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 73 |

SURGICAL KIT BOXES AND DRILL HOLDER

SURGICAL KIT BOXES

DRILL HOLDER

Can be sterilised in an autoclave. Can be sterilised in an autoclave.

No components

Can be sterilised in an autoclave.

Kit KCQ1 Kit KCQ4

SPF

Kit KCQ2

Complete surgical kit box, including all the components necessary to insert the whole range of implants.

Surgical kit box for the BTI reduced sys-tem: Easy and predictable.

Surgical kit box for short implants, con-taining the components suitable for use with short implants.

Page 74: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 74 |

SURGICAL DRILLS

The design of the BTI drills enables you to work at low revolutions (50-75 rpm) without irrigation, which means you can recover all the bone when drilling and use it as an autograft. It is also possible to work with the parameters of conven-tional drilling, at high revolutions if required.

Drilling at low revolutions provides excellent control of the drilling depth and perfect visualisation of the depth mark-ing, reducing the chance of causing damage to significant structures. It also helps to control the direction of drilling on the vertical.

With the new drilling technique, as it is more accurate, the neo-alveolus created will house the implant with greater initial stability. At the same time, from a biological point of view, the socket, as it has been made without irrigation, will be in the best condition for revascularisation and the subsequent osseointegration of the implant.

The depth marks are at: Short drills 3, 5, 8.5, 10 and 13 mm Long drills 3, 5, 8.5, 10, 13, 15 and 18 mm

ADVANTAGES

The initial drill has a very active tip and with excellent penetration capacity in the cortical bone. It achieves precise drilling and an exact location of the starting point for the drilling, particularly in narrow alveolar crests, and better directional control. It also enables lateral drilling in case we want to modify the location of the neo-alveolus by half a millimetre. It is the ideal drill to use in immediate post-extraction implants, as it allows us to drill accurately into the wall of the post-extraction alveolus.

This drill must always be used with abundant irrigation, either with saline solution or with pyrogen-free sterile water, and at revolutions between 800 and 1,000 rpm.

The next drill is 1.8 mm diameter, with an exclusively apical cut. Its special helicoidal design is very good for retaining the bone particles that are cut. This drill is used almost exclusively in narrow alveolar crests. The rest of the drills with larger diameters are used progressively, depending on the diameter of the implant to be placed and on the bone qual-ity. They can all be used without irrigation as long as you work at low revolutions.

INTERNA AND EXTERNA

Page 75: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 75 |

FAMILYSequence drills

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

Ref. Drilling depth

F18CSF18LS

13 mm18 mm

F30CSF30LS

13 mm18 mm

F38CSF38LS

13 mm18 mm

F45CSF45LS

13 mm18 mm

Ref. Drilling depthF53CS 13 mm

FICSFIL

8 mm15 mm

F25CSF25LS

13 mm18 mm

F35CSF35LS

13 mm18 mm

F43CSF43LS

13 mm18 mm

Ref. Drilling depthF51CS 13 mm

F1825CSF1825LS

13 mm18 mm

F32CSF32LS

13 mm18 mm

F40CSF40LS

13 mm18 mm

F48CSF48LS

13 mm18 mm

INFAPUCINFAPSCINFAPACINFAPULINFAPSLINFAPAL

5 mm4.5 mm

4.5 and 5.5 mm5 mm

4.5 mm4.5 and 5.5 mm

Initial 1.8 mm ø

3.0 mm ø

3.8 mm ø

4.5 mm ø

5.3 mm ø Countersink (short and long)

2.5 mm ø

3.5 mm ø

4.3 mm ø

5.1 mm ø

1.8 > 2.5 mm ø

3.25 mm ø

4.0 mm ø

4.8 mm ø

INTERNA® AND EXTERNA

Narrow

Universal

Universal Plus

Wide

Page 76: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 76 |

FAMILYSurgical drills

Ref. Length Ref. Length

Ref.

Ref. Length

KFD1 (3 units) Start Pilot 1.8 - 2.5 mm Pilot 2.5 - 3.0 mm

15 mm18 mm18 mm

KFD2 (4 units) Start Pilot 1.8 - 2.5 mm Pilot 2.5 - 3.0 mm Pilot 3.2 - 3.8 mm

15 mm18 mm18 mm18 mm

FPTINFPUINFPA

EXFRCEXFR

Disposable kits Disposable kits

Profiling drills

Drill extension

INTERNA® AND EXTERNA

The kit is designed for use in conjunction with the BTI implant system, for both external and internal connection in all platforms; nevertheless, for implants with larger diameters, it will be necessary to use wider conventional drills to be able to complete the drilling procedure. With regard to the working lengths, the drills have depth marks at: 3 mm, 5 mm, 8.5 mm, 10 mm, 13 mm, 15 mm and 18 mm.

BTI profiling drills are actually profiling screwdrivers, as they must be used with the socket wrench ref. LLEC in order to profile the bone around the implant.

Manual use is recommended for greater control and sensitivity.

This adapts the drills, lengthening them by 18 mm, facilitating drilling in areas where access is hindered by long adjacent teeth. Manufactured from surgical stainless steel

Re-use and/or re-sterilisation of these single-use products may cause risk of infection and/or cross contamination.

15 mm18 mm

Narrow

Universal

Universal Plus

Wide

Page 77: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 77 |

FAMILYSurgical and other drills

Ref. ø (mm.) Drilling depthFCF30LFCF35LFCF45LFCF51L

15 mm15 mm15 mm15 mm

Front cutting drill

INTERNA® AND EXTERNA

The front cutting drills are designed to achieve maximum settlement for extrashort implants and to work the cortical bone in transalveolar sinus elevations and in proximity to the dental nerve.

These must be used when the appropriate alveolus for their diameter has been prepared, thus making an apical instrumentation at the base of the sinus and/or allowing further advancement of the extrashort implant, achieving excellent primary stability and avoiding compression.

33.54.55.1

APEX

NECK

DEPTH MARKS

Formed by four active blades, which cut the bone without damaging compromised anatomical structures.

The innovative design means the bone can be preserved.

Marks to view the exact working height: 3, 5, 6, 8, 10, 13 mm.

Narrow

Universal

Universal Plus

Wide

Page 78: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 78 |

TREPHINE DRILLS

Ref. øFT2-6 interior

2 mmexterior 2.55 mm

Trephine drill designed for taking biopsies. The diameter is smaller in the first 6 mm: Interior Ø: 2 mm Exterior Ø: 2.55 mm

Manufactured from stainless steel.

INTERNA AND EXTERNA

INTERNA® AND EXTERNA

Narrow

Universal

Universal Plus

Wide

Page 79: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 79 |

KITTrephine drills

These drills have a smaller diameter in the first 6 mm and are indicated for:

· Extraction of expander implants of ø 2.5 mm and ø 3 mm.· Biopsies with Ø 2.7 mm and ø 3.2 mm.· Extraction of Tiny® implants ø 2.5 mm and ø 3 mm that have

broken in the cylindrical area.

Manufactured from stainless steel.

EXPLANTATION TREPHINES

TREPHINE DRILL KIT

Ref. PlatformFTEX37-5FTEX43-5FTEX51-5FTEX57-5

NarrowUniversal

Universal PlusWide

Trephine drills that can work up to a depth of 15 mm, as they have a cylindrical body with no step. These have been conceived for the extraction of implants or bone blocks for particulate grafting.

Depth marks at 8.5, 10, 13 and 15 mm.

As a complement to the implant extraction kit, there is an ATRAUMATIC TREPHINE DRILL KIT (KFTEX-5). These drills have different diameters depending on the implant to remove. They enable the release of the area of maximum osseointegration (2-3 mm), preserving the surrounding bone and thus reducing the amount of bone eliminated in the extraction. The residual alveo-lar crest is respected as much as possible, in addition to reducing the temperatures reached during its use. They have an active limit of 5 mm, which acts as guide for the correct drilling depth.

Ref. ø (interior) Drilling depthFTEX27-6FTEX32-6

6 mm6 mm

2.7 mm 3.2 mm

Ref. ø (mm.) PlatformFTEX37FTEX43FTEX51FTEX57

NarrowUniversal

Universal PlusWide

3.74.35.15.7

Narrow

Universal

Universal Plus

Wide

Page 80: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 80 |

CENTRING DEVICES

The platform positioners facilitate the selection of the im-plant platform, as its widest part has the same diameter as the colour of the platform it represents, and to verify the dis-tance between the platforms of the implants or between teeth and implants.

Its narrowest end can be positioned after the initial drilling, with an additional use as direction indicators. The widest end is inserted into neoalveolus after the 2.5 mm drill (for the Uni-versal platform) and after the 3.25 mm drill (for the Wide plat-form).

The short centring devices are used in the surgical preparation of the alveolus for extra-short implants, with lengths between 5.5 and 7.5 mm.

Long

Short

Ref.

Ref.

CPECPUCPUPCPA

CPECCPUCCPUPCCPAC

INTERNA® AND EXTERNA

INTERNA AND EXTERNA

Narrow

Universal

Universal Plus

Wide

Page 81: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 81 |

IMPLANT MOUNT CONNECTOR

Indicated for transporting the implants to the alveolus. They are inserted in the counter-angle, programming the motor at low revolu-tions (between 15-25 rpm). The long connector is ideal for the ante-rior area and the short one is adequate in posterior areas.

The CPI19 and CPI22HEX connectors incorporate a hexagon, which fits perfectly into the mounting of the counter-angle CA-HEX, which makes it possible to work with torques of 20-25 Ncm more safely.

The CPI22 is used for counter-angles without hexagons with a larger head.

Ref.CPI19 (short without hex.)CPI22 (long without hex.)CPI22HEX (long with hex.)CPI30

INTERNA® AND EXTERNA

INTERNA AND EXTERNA

Narrow

Universal

Universal Plus

Wide

Page 82: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 82 |

RATCHET WRENCH EXTENSION

The BTI extenders are inserted in the LLMQ wrench for the final application of the insertion torque on any of the BTI im-plant mounts.

Available in three lengths, the long one for anterior areas, the short one for posterior areas that are difficult to access and the extra-long one for significant reabsorption.

Ref. mm

INTERNA® AND EXTERNA

Manufactured from surgical stainless steel

ELLCAC (short)ELLCAL (long)ELLCAX (extra-long)ELLCAXL (ultra-long)

11.5202530

Narrow

Universal

Universal Plus

Wide

INTERNA AND EXTERNA

NOTE

It is possible to replace the clear rubber o rings of these items.

Ref.RJPT

Page 83: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 83 |

IMPLANT MOUNT

Designed with extra-long length for each of the platforms, it is indicated for placing implants in the anterior sector, between natural teeth, when the adjacent space is minimal and to finish securing the implant in flapless techniques. Fitted on the implant we transfer it to the alveolus with the connector for the handpiece CPI19 (short), CPI22 (long), CPI22HEX. With the ratchet wrench LLMQ, and the wrench extender ELLCAC (short), ELLCAL (long), we make the final manual adjustments of the implant to ensure its stability. With depth marks at 2 and 4 mm for the placement of implants in flapless techniques.

Manufactured from surgical stainless steel and laser marked.

Ref.PITELPIULPIAL

EXTERNA®

Narrow

Universal

Universal Plus

Wide

EXTERNA

Page 84: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 84 |

INTERNA® APPLICATOR EXTENSION

Extenders for the dynamometric surgical wrench, whose function is to finish positioning the Interna® implant (supra-juxta-subcrestal) during its surgical insertion.

On one end they have a connection to this surgical wrench and on the other the connection shape. Thus, during the implant placement the position of the figure can be cor-rected by turning it easily without having to screw the im-plant mount on and unscrew it afterwards.

INTERNA

INTERNA®

Narrow

Universal

Universal Plus

Wide

Ref.

Ref.

EAIE24EAIE29

EAI15EAI24EAI29

NOTE

It is possible to replace the clear rubber o rings of these items.

Ref.RJPT

Page 85: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 85 |

DYNAMOMETRIC SURGICAL WRENCH

Ref. LLMQ

Surgical ratchet wrench with torques 20, 30, 40, 50, 60 and 70 Ncm enables you to know the exact insertion torque of the implant in the maxillary bone.

In order to decide which torque to apply, BTI's scientific directorate recommends detecting the bone density with den-sity identification tools, such as the implant simulation and diagnosis software based on CT scans, BTI Scan® 3.

For suitable fitting of the implant with a controlled torque, the surgical motor must be set at 20-25 Ncm and the implant inserted. Once the preset torque has been reached in the motor (20-25 Ncm), continue the manual insertion with the wrench, setting the desired torque depending on the bone quality and the calibre of the implant; thus, in narrow im-plants or in cases of wide implants poor quality bone (Type IV-V), the wrench must be positioned at 40 Ncm; otherwise, with wide implants placed in bone type I, II or III, the torque selected shall be 50 Ncm.

INSTRUCTIONS FOR USE

Rotate the torque range regulator in both directions to achieve the desired torque; the torque is read using the markings on the handle of the wrench: 20, 30, 40, 50, 60, 70 Ncm.

Once the torque has been set, fit the adapter of the ratchet wrench and proceed to the insertion of the implant. When the preset torque has been reached, the wrench will turn without applying torque (with a characteristic sound).

Narrow

Universal

Universal Plus

Wide

INTERNA AND EXTERNA

Page 86: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 86 |

INSTRUMENTS FOR PROSTHODONTICS

This chapter presents all the instruments necessary to secure the prosthe-sis on the implant or transepithelial, as well as the wrenches to apply the minimum torque necessary and the kits to which they are linked.

At the end of the chapter there is chart summarising the possible combi-nations between wrenches and tips to facilitate their use in the clinic and laboratory.

Women who are pregnant or breastfeeding: There are no additional precautions other than those generally contemplated in techniques of oral implantology.

Page 87: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 87 |

CONNECTIONSTips and screwdrivers

All the screwdrivers are manufactured from surgical stainless steel. The tip of these screwdrivers is conical, which enables it to retain the part and transport it to the mouth.

The square tip secures the gold screws directly to the implant.

SQUARE

Ref. LengthDC17DC24DC36

17 mm24 mm36 mm

ScrewdriversDetails of tip

Narrow

Universal

Universal Plus

Wide

The large hexagonal tip is used for the titanium screws, transepithe-lial abutment screws, healing abut-ments, protection covers and im-plant transporter screws.

LARGE HEXAGONAL Details of tip

Ref. LengthDHG17DHG24DHG36

17 mm24 mm36 mm

Screwdrivers

The small hexagon tip is used for the headless healing screws.

SMALL HEXAGONAL Details of tip

Ref. LengthDHP24 24 mm

Screwdriver

INTERNA® AND EXTERNA

INTERNA® AND EXTERNA

Ref.DIRO

Of the occlusal registration indicator(direct technique)

MULTI-IM®

Ref. LengthDCE17DCE24

17 mm24 mm

For transepithelials

Page 88: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 88 |

MULTITORQUE WRENCH

Ref. LLMTP

Multitorque wrench that uses the existing torque tips and screwdriver tips, in the appropriate handles for each. They must be inserted into one of the bodies of the screwdriver supplied. The set can be used as a manual screwdriver.

The screwdrivers fit into the multitorque wrench to apply the torque controlled on the scale.

The range of torques is: 10 - 20 - 30 and 35 Ncm.

They are used to apply the required torque to the retention screws, abutments and transepithelials.· 20 Ncm, for healing abutments, titanium screws for transepithelials, Dalbo® and small-headed screws.· 30 Ncm , for the Locator abutment.· 35 Ncm, for gold square universal screws, direct-to-implant Ti-Black screws and transepithelials.

The torque wrench needs cleaning before each use. For each sterilisation it is advisable to use an autoclave or chemi-clave. Short-cycle sterilisers are not recommended. They must also be verified after approximately 100 sterilisation processes.

INTERNA AND EXTERNA

Page 89: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 89 |

INTERNA AND EXTERNA

TORQUE TIPS

Ref. LengthPTHP16PTHP22

16 mm.22 mm.

TORQUE TIPS

Ref. LengthPTCS16PTCS22

16 mm.22 mm.

Ref. LengthPTHS16PTHS22

16 mm.22 mm.

Small hexagonHexagonal Square

Attention: only for healing screws for Tiny® and headless screws.

Parallel walls Parallel walls

These tips can be converted into manual screwdrivers with the handle MDPT and the MDPT1.

Narrow

Universal

Universal Plus

Wide

Ref. Length Ref. LengthPTTL15PTTL21

15 mm.21 mm.

PTDO 16 mm. Ref. Length

PTTU16PTTU22

16 mm.22 mm.

PTUA16 16 mm.

LocatorMulti-Im®UNIT

Dalbo®

NOTE: UNIT TRANSEPITHELIAL WIDE PLATFORM needs a spe-cific torque wrench tip:

These are necessary to apply the appropriate torque to screw-retained elements. The nitriding treatment gives them a greater hardness, so they experience less wear with use.

The design in the connection area enables a more gentle insertion and stronger fitting.

NOTE

It is possible to replace the clear rubber o rings of these items.

Ref.RJPT

Page 90: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 90 |

TORQUE TIPS ANGLED HEXAGONAL

Ref. Length Ref. LengthPTHA16PTHA22PTHA28PTHA34

PTHB16PTHB22PTHB28PTHB34

16 mm22 mm28 mm34 mm

16 mm22 mm28 mm34 mm

TORQUE TIPS (CAD-CAM)

Angled hexagonal Angled hexagonalAngles from 0 to 15º Angles from 15 to 30º

These tips can be converted into manual screwdrivers with the handle MDPT and the MDPT1.

Narrow

Universal

Universal Plus

Wide

INTERNA AND EXTERNA

Spherical torque tips with 6 faces that enable you to resolve vestibular prosthetic emergences and the inadequate emergences from an occlusal point of view between 15º and 30º, changing them to the aesthetic and functional position required.

The maximum torque recommended is 20 Ncm.

They come in 2 different sphere diameters:

· The small one is for angles of up to 15º and is indicated for small-headed screws.

· The large one is for angles of 30º, only for use with the TTMI30, TTTH30, INTTUH30 and TTUH30.

In addition there are 4 different lengths available.

NOTE

It is possible to replace the clear rubber o rings of these items.

Ref.RJPT

Page 91: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 91 |

PROSTHETIC KIT

A kit designed to achieve an adequate torque in each of the elements that need to be screw-retained, for carrying out the prosthetic work.

KIT KP1

Square screwdriver tip

Large hexagonal screwdriver tip Multitorque wrench for prostheses

Ref. Length

Ref. Length Ref.

PDC17PDC24

PHG17PHG24

LLMTP

17 mm24 mm

17 mm24 mm

INTERNA AND EXTERNA

Page 92: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 92 |

RIGHT-ANGLE SCREWDRIVER

Ref. DAR (Screwdriver + handle)Ref. MDAR (Screwdriver handle)

This screwdriver consists of two components: the handpiece with reduction 1.2:1 and the handle that adapts to the handpiece. Turning the handle produces the rotation of the interchangeable screwdriver tips. It can be used for insert-ing or removing screws or healing abutments.

The components of the handpiece are reinforced so that the application of torque does not deteriorate the splines; its special design enables it to be perfectly cleaned, lubricated and sterilised like any surgical handpiece. It enables the application of up to 80 Ncm of torque, so we must monitor the force when tightening screws; otherwise, they shall be an instrument of choice for unscrewing tightened parts with a high torque.

It is an essential instrument in both surgery and prosthetics when working in the rear sector, as it provides easy ac-cess and prevents the screwdriver accidentally being swallowed or inhaled.

It must never be used as a motorised counter-angle.

INTERNA AND EXTERNA

Page 93: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 93 |

FAMILYScrewdriver tips

Ref. Length

Ref.

Ref. Length

Ref. Length

Ref.

Ref. Length

Ref. LengthPHG17PHG24PHG30

17 mm24 mm30 mm

LLEC1

PTL23PTL29

23 mm29 mm

PDC17PDC24PDC30

17 mm24 mm30 mm

LLEC

PDP24 24 mm

PHP24 24 mm

Square

Flat

Hexagonal (large)

Locator

Hexagonal (small)

INTERNA® AND EXTERNA

SOCKET WRENCHES

Attention: only for healing screws for Tiny® and headless screws.

Attention: exclusively for Interna® in Universal, Universal Plus and Wide platforms.

With these socket wrenches, the screwdriver tips can be converted into manual screwdrivers.

Narrow

Universal

Universal Plus

Wide

Page 94: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 94 |

SUMMARY OF COMBINATIONS

MDPT

LLMTP

Angled hexagonal Angles from 15º to 30º (CAD-CAM)

For Locator transepithelials

Ref. LengthAngle 15º PTHA16 PTHA22 PTHA28 PTHA34

Angle 30º PTHB16 PTHB22 PTHB28 PTHB34

16 mm22 mm28 mm34 mm

16 mm22 mm28 mm34 mm

Dalbo

MDPT1

Angled hexagonalAngles from 0 to 15º (CAD-CAM)

Hexagonal

Square

Small hexagon*

Ref. Length

Ref. Length

Hexagon (p.) PTHS16 PTHS22

Small hex. PTHP16 PTHP22

16 mm.22 mm.

16 mm.22 mm.

Square (p.) PTCS16 PTCS22

16 mm.22 mm.

*Attention: only for healing screws for Tiny® and headless screws.

Parallel walls

Parallel walls

For Multi-Im® transepithelials ( ) and UNIT ( )

Ref. Length

Ref. Length

Locator PTTL15 PTTL21

Dalbo PTDO

15 mm.21 mm.

16 mm.

PTTU16PTTU22

16 mm.22 mm.

PTUA16 16 mm.

NOTE: UNIT TRANSEPITHELIAL WIDE PLATFORM needs a specific torque wrench tip:

Page 95: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 95 |

LLMTP

LLEC1

LLEC

DAR

Large hexagon Small hexagon

For Locator transepithelials

Flat

Square

Ref. Length

Ref. Length

Ref. Length

Ref. Length

Large hex. PHG17 PHG24 PHG30

Small hex. PHP24

17 mm24 mm30 mm

24 mm

PDC17PDC24PDC30

17 mm24 mm30 mm

PTL23PTL29

23 mm29 mm

PDP24 24 mm

Page 96: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 96 |

SURGICAL INSTRUMENTS AND KITS

This section presents different kits that BTI provides for specific surgical techniques and hand-held surgical instruments with special BTI design features.

Women who are pregnant or breastfeeding: There are no additional precautions other than those generally contemplated in techniques of oral implantology.

Page 97: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 97 |

SOME TECHNIQUES THAT CANBE PERFORMED WITH THE BTI KITS

CRESTAL EXPANSION

IMPLANT EXPLANTATION

BLOCK GRAFTS

Page 98: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 98 |

Ref. Description Ø Apex Ø Body Length

ECO1ECO2ECO3ECO4

ELLCALCPI22

Expander No. 1 1.4 mm 2.0 mm 15 mmExpander No. 2 1.6 mm 2.6 mm 15 mmExpander No. 3 2.1 mm 3.1 mm 15 mmExpander No. 4 2.8 mm 3.8 mm 15 mm

Long ratchet wrench extensionLong implant mount connectorSilver metal box

Narrow

Universal

Universal Plus

Wide

Long expanders

Ref. Description Ø Apex Ø Body Length

COMP1COMP2COMP3COMP4

ELLCACCPI19

Compactor No. 1 1.4 mm 2.0 mm 11.5 mmCompactor No. 2 1.6 mm 2.6 mm 11.5 mmCompactor No. 3 2.1 mm 3.1 mm 11.5 mmCompactor No. 4 2.8 mm 3.8 mm 11.5 mm

Short ratchet wrench extensionShort implant mount connectorRed metal box

Short compactors

EXPANDERS KIT ANDCOMPACTORS KIT

The BTI expanders and compactors are indicated for Crestal expan-sion in the upper and lower maxilla. Also for bone compactation and atraumatic sinus elevation. They can be used jointly with the BTI drills.

They can be used with a motor or manually. When used with the motor with the CPI22HEX, they must not exceed a torque of 25 Ncm.Material: commercially pure titanium.

INDICATIONS

Alveolar crest expansion in bone type I, II and III. In both anterior and posterior areas in the upper maxilla or mandible. Condensation or compaction of the bone to place implants in bone Type IV in posterior areas of the maxilla or mandible.

EXPANDERS KIT | REF: JEXP

COMPACTORS KIT | REF: JCOM

The short compactors are specific for the treatment of posterior areas of the upper maxilla and they are specially designed for pa-tients with a limited oral opening.

They have depth marks at 8.5 mm, 10 mm and 11.5 mm.

Page 99: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 99 |

KIT OF EXPANDERSCOMPACTORS

Ref. Description

FICSJEXPJCOM

Short initial drillSet of expandersSet of compactors

Sterilisable plastic box

REF: KEXCO

Long expanders + Short compactors

This consists of the long expanders and the four short com-pactors, with which all bone expansion and compaction needs can be resolved for all types of patients.

Narrow

Universal

Universal Plus

Wide

Page 100: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 100 |

EXPLANTATION KIT

This innovative system enables the safe and traumatic extraction of implants with both internal and external connec-tions of practically any brand of dental implants with prosthetic connection.

The extractors are inserted in the connection of the implant and adapted, using an extender, to the special wrench included in the kit. Thus the implants are detached safely by torsion, as bone-implant union is broken. In the event 200 Ncm is reached, the wrench forms an angle and prevents progress. If necessary, it is repositioned using a cylindrical part.

INDICATIONS

· The system is indicated for the extraction of osseointegrated implants when they are no longer functional or are unnecessary in a new prosthetic situation.

· It enables the safe, atraumatic extraction of implants, in most cases avoiding the use of the traditional protocol of extraction using a trephine drill.

· Each kit comes equipped with detailed instructions for use.

As a complement to the Implant extraction kit, there is an Atraumatic trephine drill kit (KFTEX-5). (Page 75)

+ More information on the explantation kit in the brochure “Implant extraction system”.

Page 101: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 101 |

COMPONENTS

ADDITIONAL REFERENCE

KEXIM2

COMPONENTSKEXIM KIT

Ref. Ncm

Ref. Length

Ref.

Ref.

Ref.

Ref.

LLT200 200

ELLCACELLCALELLCAX

11.5 mm20 mm25 mm

INEXIM2

EXIML-AEXIML-BDRL-E

MDPT

NO. 0 - EXIME Maximum 70 Ncm.NO 1 · EXIMNO 2 · INEXIMLNO 3 · INEXIMNO 4 · EXIMA

Countertorque wrench

Extenders

Handle

Extractors

Exclusively for the Interna® connection by BTI.

New kit that will be used to extract implants with connections that are complex due to their depth and for the extraction of BTI interna implants with stripped connection. KEXIM2 is composed of:

· 1 unit. Drill for fractured external screw (DRL-E)· 2 units. Extractor for complex internal connection implants A (EX-

IML-A)· 2 units. Extractor for complex internal connection implants B (EX-

IML-B)

They enable the extraction of internal connections that are very deep

and very conical, in those where the EXIM cannot reach, improving the fixation to the implant and increasing its mechanical resistance.

Note: These extractors are single-use.

Note: These extractors are single-use.

This kit complements the KEXIM.

Narrow

Universal

Universal Plus

Wide

Page 102: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 102 |

RECOVERY KITFOR FRACTURED SCREWS

INTERNA AND EXTERNA

Ref.

INEQREC (for use in Interna®)

EQREC (for use in Externa)

Kit for fractured screws This is a kit to use in the event of breakage of the screw be-tween the prosthesis and the implant (TOUC, TOOC, TTUH, TOTC and TTTH).

Includes tools for removing the screw body left inside the internal thread of the implant and others for renewing this thread thus enabling the use of a new screw and making the implant functional once more.

+ More information about this kit and its use on the website: www.bti-biotechnologyinstitute.es

Narrow

Universal

Universal Plus

Wide

Page 103: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 103 |

INTERNA AND EXTERNA

RECOVERY KITFOR STRIPPED SCREWS

This is a kit to use when the large hexagon or square head of the universal screw, the healing micro screw, the screw of the transepithelials cylinder (straight, 15º or 30º) or the hexagon head of the transepithelials placed in the implant are stripped.

If when one of the aforementioned screws is tightened, a greater torque than recommended is applied, it may end up unusable, preventing it from being tightened or extracted.

Ref.

EQRED

Kit for stripped screws

+ More information about this kit and its use on the website: www.bti-biotechnologyinstitute.es

Narrow

Universal

Universal Plus

Wide

Page 104: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 104 |

ADDITIONAL SURGICALINSTRUMENTS

BTI presents its line of Surgical Instruments with a wide range of products to satisfy all your needs during surgery.

Many of the instruments incorporated are exclusively designed by BTI.

All the high quality, precision instruments.

+ More information about surgical instruments in the brochure “Surgical instruments”.

Page 105: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 105 |

COMPONENTS

Ref.

Ref.

Ref.

Ref.

Ref.

Ref.

Ref.

Ref.

Ref.

Ref.

PMC

DPZ

TCMC

PIBPIBC

DMS1DMS2DMS3

MMC

EPA

PAMC6

COQ

PER1PER2PER3PER4

Pincers for microsurgery

Periosteal rasp

Curved scissors for microsurgery

Pincers for block grafts

Sinus elevation kit

Microscalpel handle

Papilla rasp

Needle holder for microsurgery

Surgical compass

Periotomes

Page 106: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 106 |

DEVICES

This chapter contains the electromedical devices that BTI makes available: BTI Drill-Tech® surgical motor and BTI Ultrasonic.

Women who are pregnant or breastfeeding: There are no additional precautions other than those generally contemplated in techniques of oral implantology.

Page 107: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 107 |

BTI DRILL-TECH®SURGICAL MOTOR

"BTI Drill-Tech®” is the motor that BTI Biotechnology Institute markets and recommends for the placement of BTI im-plants. The handpiece “CA-HEX” adapts perfectly to the surgical instruments necessary for the BTI implant system.

FEATURES

· Conceived particularly for surgical interventions in implantology, as well as in oral and maxillofacial surgery.

· Easy to handle.

· Motor without brushes, friction-free.

· Strong and powerful rotation moment and precise control of the torque limit.

· Provides a wide range of rotation speeds (15 - 50,000 rpm.) depending on the handpiece used:

- Straight handles (1:1): speed 300 - 50,000 rpm. (not supplied by BTI)

- Counter-angle CA-HEX (reducer 20:1): speed 15 - 2,500 rpm.

· Irrigation pump of 90 ml/min.

Programme selected using the pedal

· P1: indicated for the initial drilling, with irrigation.

· P2: is the option for the rest of the drilling sequence.

· P3: is used to insert the implant and for the use of motorised expander-compactors.

· P4: is suitable for the opposite rotation direction.

· P5: must be used only with straight handles at high revolutions.

+ More information about this product in the brochure “BTI apparatus for implant surgery”.

Page 108: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 108 |

Circular spatula tip at 140ºTo carry out corticotomies and cortical scraping prior to the reception of a block graft.

Power · 40 Vibration · 80 Irrigation · 45

Circular spatula tip at 140ºTo carry out corticotomies and cortical scraping prior to the reception of a block graft.

Power · 40 Vibration · 80 Irrigation · 45

Mini circular spatula tip at 140ºFor sinusoidal corticotomies.

Power · 40 Vibration · 80 Irrigation · 45

Spatula tip For corticotomies.

Power · 48 Vibration · 10/80 Irrigation · 45/60

Straight periotomy tipTo extract root fragments and ankylosed teeth.

Power · 50 Vibration · 50/100 Irrigation · 45/60

Straight periotomy tipTo extract root fragments and ankylosed teeth.

Power · 50 Vibration · 50/100 Irrigation · 45/60

Straight periotomy tip, rotated 90ºTo extract root fragments and ankylosed teeth.

Power · 50 Vibration · 50/100 Irrigation · 45/60

UT1

UT1

UT1A

UT5

UT4

UT4

UT4A

BASIC KIT

SINUS ELEVATION KIT (KES)

BTI ULTRASONIC TIPS KITSpecific tips

Page 109: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 109 |

BTI ULTRASONIC TIPS KITSpecific tips

Circular spatula tip at 140ºTo carry out the vertical incisions when extracting a block graft and to carry out corticotomies and cortical scraping prior to the reception of a block graft.

Power · 40 Vibration · 80 Irrigation · 45

Spatula tipTo make the longitudinal crestal bone incision of the graft.

Power · 48 Vibration · 10/80 Irrigation · 45/60

Left spatula tipTo make the lower longitudinal corticotomies of the block. Useful for the left approach.

Power · 40 Vibration · 80 Irrigation · 45

Right spatula tipTo make the lower longitudinal corticotomies of the block. Useful for the right approach.

Power · 40 Vibration · 80 Irrigation · 45

UT1

UT5

UT6L

UT6R

Circular spatula tip at 140ºTo carry out corticotomies and cortical scraping prior to the reception of a block graft.

Power · 40 Vibration · 80 Irrigation · 45

Spatula tip For corticotomies.

Power · 48 Vibration · 80 Irrigation · 45

Rounded periotomy tipFor crestal splits.

Power · 50 Vibration · 50/100 Irrigation · 45/60

Rounded periotomy tip, rotated 90ºFor crestal splits.

Power · 50 Vibration · 50/100 Irrigation · 45/60

UT1 UT5

UT3

UT3A

BLOCK GRAFTS KIT (KIB)

CRESTAL SPLIT KIT (KSC)

Page 110: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 110 |

MICROIMPLANTS FOR ORTHODONTICS

Ref. Kit: KIO

BTI offers microimplants for orthodontics manufactured from Grade 5 Titanium alloy with different diameters and lengths, designed to be the fixed anchor for the different orthodontic movements, used as a complement to natural teeth for this purpose. They are used temporarily while they are needed as an anchor, and are later removed. They are inserted transmucosally on adhered gum.

CHARACTERISTICS OF THE HEAD

· The head of these implants has two crosswise grooves that house the

corresponding screwdriver during insertion.

· Similarly there is a hexagonal area so they can be manipulated with the

system connector.

CHARACTERISTICS OF THE THREAD

· The external thread has a self-tapping profile with a sharp tip, so drilling is not performed prior to the insertion of the implant.

· The thread profile is anti-expulsion, in order to withstand the tractions to which it is subjected.

· It has a wide thread pitch to avoid breaking the bone.

· The threads are 0.5 mm deep.

Children: They are indicated for this population group for temporary use.

Women who are pregnant or breastfeeding: There are no additional preventive measures other than those generally accepted in oral im-plantology techniques. However, this particular situation should be considered by the clinician before placing the implants.

Re-use and/or re-sterilization of implants may cause risk of infection and/or cross contamination.

Page 111: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 111 |

MICROIMPLANTS KITComponents

MICROIMPLANTS

AUXILIARY ELEMENTS

Ref. ø (mm) Length

Ref.

Ref. Length

Ref.

IO1485 1.4 IO1410 1.4IO1885 1.8 IO1810 1.8

8.5 mm10 mm8.5 mm10 mm

CPIO

PPIO21 21 mm

CIO

Connector

Screwdriver tip

Sterilisable box

With a standardised end for use with the counterangle or alternatively with socket wrench LLEC or LLEC1. It is in-serted in the crosswise groove of the microimplants.

CPIO for implant insertion or extraction. Use the hexagonal head of the implant for ma-nipulation.

CIO where the implants can be housed in order of diameter and length, as well as the components PPIO21 and CPIO. In addition, it has a measure to be able to check the measurements of the implants. This box is made of plastic and is resistant to sterilization by autoclave.

Page 112: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 112 |

BLOCK GRAFTS KIT

Ref. Kit: KTO

The kit of osteosynthesis screws is designed to secure bone blocks in the recipient area to be grafted in oral and maxil-lofacial surgery processes.

The screws are for single use to guarantee their effectiveness and avoid cross contamination.

ADVANTAGES

· Smaller screw diameter, therefore less invasive.

· They can secure small grafts with minimum thicknesses.

· They have a self-tapping apex.

Page 113: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 113 |

COMPOSITION OF THE KITComponents

Countersink drill Manufactured from stainless steel

Drill 0.8 mmManufactured from stainless steel

Osteosynthesis screws with Ø 1 mm and different lengthsManufactured from titanium

Screwdriver transporter square tip

Osteosynthesis screws with Ø 1.2 mm and different lengthsManufactured from titanium

Drill 0.7/1 mmManufactured from stainless steel

Ref. Description

Ref. Description

Ref. Description

Ref. Length Ref. Length

Ref. Description

F0508CS

F0710CS

DCTO

TO1004TO1006TO1008TO1010

TO1204TO1206TO1208TO1210

FIO050.8 mm diameter throughout the whole length.It is used to perforate the block completely, when using the 1 mm screws.Drilling speed: 500 rpm with irrigation.

The apex has a diameter of 0.7 mm and the rest of the body is 1 mm.It is used to perforate the block completely, when using the 1.2 mm Ø screws.Drilling speed: 500 rpm with irrigation.

Square tip screwdriver, self-carrying for the screws.Manufactured from stainless steel.

4 mm6 mm8 mm

10 mm

4 mm6 mm8 mm

10 mm

Helps the seating of the screw head.The black mark indicates the maximum depth.

Page 114: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 114 |

KITS FOR OBTAINING Endoret® (PRGF®)

Endoret® (PRGF®) technology and all its component elements have been specifically designed by the department of R&D&I at Biotechnology Insti-tute (BTI) to obtain Plasma Rich in Growth Factors (Endoret® (PRGF®)) for its subsequent application to different specialities.

BTI offers its users in the field of oral surgery single-use kits with the necessary equipment for the habitual surgical treatment.

With these single-use kits we increase the biosafety of the treatment, reducing the working time and avoiding the sterilization of the materials for use. They also comply with the quality standards required by the European health authorities.

Children, and pregnant and lactating women: There are no additional preventive meas-ures other than those generally considered for Endoret® (PRGF®) technology. However, these particular situations should be considered by the clinician before its application.

The reuse and/or resterilization of single-use components that comprise Endoret® (PRGF®) technology can cause a risk of infection and/or cross contamination.

Page 115: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 115 |

BTI SINGLE-USE KITS

ORAL SURGERY

All the necessary elements for a new user in oral sur-gery to start working with Endoret® (PRGF®) technol-ogy®.

This new single-use plasma fractionation kit has all the necessary elements for the Endoret® (PRGF®) technique in oral and maxillofacial surgery. The KMU15 kit is com-posed of 10 blister packs for individual treatment. In addition, each KMU15 contains one blister pack of ad-ditional material.

For surgery with greater demand for material, the KMU15 PLUS Kit is available with 10 blister packs for individual treatment.

This new single-use plasma fractionation kit has all the necessary elements for the Endoret® (PRGF®) technol-ogy in alveoluses post-extraction. The KMU16 kit is composed of 15 blister packs for individual treatment.

1. Fast: Without the need for anticoagulant or Ca as an activator, the processing is much faster.

2. Simple: Fewer steps, less material, fewer mistakes.

3. Biological: The formation of the fibrin membrane and the clot is faster and its capacity to retain growth factors is greater.

Ref. Content

Ref. Content of each blister pack: Content of additional blister pack

Ref. Content of each blister pack

Ref. Content of each blister pack

PTD-0

KMU15

KMU15 PLUS

KMU16

KMU15 KITCD: one digital chronometer unitGT16: a rack for 9 ml tubes3 RPI50: a container for Ø50 mm grafts

4 extraction tubes 8 extraction tubes2 fractionation tubes 4 fractionation tubes1 ampoule of activator 2 ampoules of activator1 activation syringe1 PTD21 winged blood collection set5 identification labels

8 extraction tubes4 fractioning tubes2 ampoules of activator1 activation syringe1 PTD21 winged blood collection set5 identification labels

4 extraction tubes without anticoagulant2 fractioning tubes1 PTD21 winged blood collection set5 identification labels

Kit START PTD-0

KMU15 Kit

KMU15 PLUS Kit

Kit KMU16

Page 116: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 116 |

SINGLE-USE MATERIAL OF THE KITSBTI protocol

PRGF activatorPlasma Transfer Device (PTD2)

Fractioning tubes

Activating syringe

Winged blood collection set

Extraction tubes

Extraction tube, no additives

· Single-use and disposable system of aspiration and fractioning of Endoret® (PRGF®).

· Individually blistered and sterilised units.· Does not need calibration or maintenance.· Ergonomic: light and easy to use.

· 1 ml ampoule of calcium chloride.· Steril inside, protected in individual containers.· Indicated for activating Endoret® (PRGF®), in a biologically controlled way.

· Capacity: 9 ml.· With an anticoagulant that does not activate the platelets non-specifically.

· Sterile inside. · Tubes approved for the preparation of Endoret® (PRGF®) ( Medical device).

· Capacity: 9 ml.· Sterile inside.· Tubes approved for the preparation of Endoret® (PRGF®) ( Medical device).

· Capacity: 9 ml.· Sterile inside. · Tubes approved for the preparation of Endoret® (PRGF®) ( Medical device).

· Blood extraction tube with grey cap, that does not contain any type of anticoagulant, so subse-quent activation is not necessary.

· Syringe intended for the controlled activation of Endoret® (PRGF®).

· 0.5 ml capacity.· Sterile, individually blistered and disposable.

· Winged blood collection sets.· Sterile, individually blistered.· Closed system for blood extraction.

Page 117: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 117 |

NECESSARY COMPONENTSEndoret® (PRGF®) technology

· Specific equipment designed and approved by the health authorities for the preparation of Endoret® (PRGF®), unlike laboratory centrifuges.

· Removable and sterilisable tube holder with capacity for 8 tubes of 9 ml.· Dimensions: width: 36 cm / height: 27 cm (closed), 36 cm. (open) / depth: 42 cm· Weight: 15.4 kg.

· Enables the bio-medical objects to be obtained more quickly and easily (clots, grafts, fibrin membranes).· Maintains a constant temperature of 37 ºC +/-1.· Capacity for different recipient sizes (racks, dishes, etc.).· Sterilisable removable trays.· Dimensions: width: 23 cm / height: 17 cm / depth: 20 cm· Weight: 3.645 kg.

· Specially designed to maintain asepsis of the plasma throughout the process.· It has nine lateral windows that facilitate viewing the volume.· With a protective cover to maintain asepsis during transport from one room to another.· Capacity for 8 tubes of 9 ml.

· To carry out the activation phase.· Made with a biocompatible material.· With a protective cover to guarantee the aseptic conditions of the Endoret® (PRGF®).· Available in 50 ml. Autoclavable.

System IV Centrifuge

Plasmaterm H®

Rack (GT16)

Activation recipient (RPI50)

+ More information on Endoret® (PRGF®) technology in the brochure “Endoret® (PRGF®), Plasma Rich in Growth Factors. Application in oral surgery”.

Page 118: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 118 |

Children: Permanent implants are not intended for use in children who have not concluded their growth and development stages.

Women who are pregnant or breastfeeding: There are no additional precautions than those generally considered in radiology and oral implantology techniques, nevertheless, these states must taken into account by the clinician, before subjecting the patient to a ra-diology examination (CT) and subsequent use of BTI Scan® 3 for diagnosing and planing implant treatment.

BTI Scan® 3

This section presents the software that BTI has developed to facilitate implant surgery.

Page 119: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 119 |

WHAT IS IT?

BTI Scan® 3 is a software application for the diagnosis and digital plan-ning of treatments that allow you to guarantee higher quality and predictability of implantological surgery.

After the radiologist performs the scan of the patient, a set of slices are obtained that are sent to the dentist on a CD-ROM, in order to view the case in three dimensions and make the corresponding study us-ing a computer with the software BTI Scan® 3.

DESCRIPTION

ADVANTAGES

Ref. Intended forBTI SCAN 3 REDBTI SCAN 3 ACTBTI SCAN 3 ADL

NetworkUpdateAdditional online licence

A PRECISE DIAGNOSIS

A precise and safe diagnosis deciding the length, width and exact location of the implant.

SAFETY AND SUCCESS IN THE OPERATION

It allows you to determine the bone density of each point of the alveolar bone, inside and outside the implants to be fitted. In addition, it allows you to completely assess the mouth cavity and its anatomical structures, including those at risk such as the inferior dental nerve, marking it to highlight it visually.

COMFORTABLE AND SIMPLE

It is a simple and intuitive program. All the information will be quickly within reach. Easy network or single-user instal-lation.

CONFIDENCE FOR YOUR PATIENTS

BTI Scan® 3 technology will help your patients to understand the treatment plan through the 3D simulation and

visualisation that this system offers.

+ More information about this product in the brochure “BTI SCAN 3”.

Page 120: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 120 |

OPERATION

The patient arrives at your clinic, and after an examination, they will be diagnosed with an ab-sence of teeth or the need to re-place existing ones.

BTI Scan® 3 generates panoramic images that show the mandibu-lar foramen, making possible to draw its trajectory, (which can be seen in the panoramic section and in the sectional views) and observe any dental pathology the patient may have.

With a scanner a series of axial sections are obtained which the radiologist stores on a CD-Rom that will be sent immediately to the dentist.

BTI Scan® 3 allows you to simu-late the placement of the im-plants, being able to define the length, diameter, angulation and distance between implants and teeth with greater ease. It offers your patients confidence. The 3D simulation and virtualisation of BTI Scan® 3 will allow them to feel much safer with the opera-tion.

BTI Scan® 3 reformats the axial sections to show three types of section per screen: axial, pano-ramic and sectional. BTI Scan® 3 allows you to carry out a much quicker, effective and precise analysis of the CT scan, helping to adequately plan the surgery and its long-term predictability.

The dentist can print out a final report of the planning, adding their own notes and recommen-dations for the surgery. With BTI Scan® 3 the chances of success with surgery increase consider-ably.

STEPS

Page 121: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 121 |

Page 122: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

CLEANING AND STERILIZATION

All the prosthetic components and surgical instruments are supplied clean and hermetically packaged, but only those where it is marked on the label are sterilised. The device that comes from the factory sterile is subject to the following process:

1. Cleaning and degreasing.2. Cleaning in clean room and hermetic packaging.3. Sterilization by gamma rays.

For the other devices that are not supplied sterile, all components intend-ed for use in the mouth must be sterilised in autoclave before first use. (See procedure for sterilisation in autoclave)

If the instruments are reusable, they must be reprocessed after every use.Reprocessing consists of three stages:

1. Manual or automatic cleaning.2. Manual or automatic disinfection.3. Sterilisation in autoclave.

Page 123: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 123 |

TYPES OF LABELS

Manufacturer's address Symbols according to standard EN 980 and 10553-1

Patient labels and other registry uses

FRO

NT

REA

R

REF:

201

0008

440

REF:

201

0008

440

es · Implante Interna® plataforma universal.en · Interna® universal platform implant.de · Interna® Implantat Standard-Plattform.it · Impianto Interna® piattaforma universale.pt · Implante Interna® plataforma universal.fr · Implant Interna® plate-forme universelle.

Type of implant Unfolding part

IMPLANT WITH SURFACE Optima®

IMPLANT WITH SURFACE UnicCa®

Example of an informative label that appears on all boxes of BTI dental implants with reference numbers and quality icons to be taken into account.

LOT

REF IIPU4011

ø 4.0 11.5

2009003196

2014-05

INTERNA® V.11.0

Page 124: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 124 |

INTMIPU30

201301986Z

INTERNA® MULTI-IM® TRANSEPITHELIALUNIVERSAL 3 MM

B.T.I. Biotechnology Institute, S.L.Parque Tecnológico de Álava | Leonardo Da Vinci, 14 01510 Miñano (Álava), Spain Tel.: (+34) 945 29 70 30 | Fax: (+34) 945 29 70 31 www.bti-implant.com | [email protected]

INTTUH

201207360A

HEXAGONAL TITANIUM SCREWINTERNA®

B.T.I. Biotechnology Institute, S.L.Parque Tecnológico de Álava | Leonardo Da Vinci, 14 01510 Miñano (Álava), Spain Tel.: (+34) 945 29 70 30 | Fax: (+34) 945 29 70 31 www.bti-implant.com | [email protected]

TYPES OF LABELS

STERILISED MATERIAL

UNSTERILISED MATERIAL

Page 125: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 125 |

LABELLING STANDARDISED SYMBOLS

CE marking

Expiry date. Products may be used until the end of the month indicated.

With medical prescription only

Batch number

Sterilised by irradiation

Do not re-use

Keep out of sunlight

See instructions for use

Reference

Do not re-sterilise

Keep in a dry place

Do not use if the container is damaged

Manufacturer

LOT

REF

Page 126: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 126 |

REPROCESSING REUSABLE INSTRUMENTS

After every surgical use, submerge the instruments in a cleaning solution, according to the manufacturer’s instruc-tions, to prevent the fluids and residue drying and to facilitate the subsequent cleaning and disinfection.

MANUAL CLEANING AND DISINFECTION

1. Remove the majority of the impurities with a soft-bristle brush using running water at ambient temperature.2. Disassemble the instruments (if applicable); callipers and others instruments with joints must be opened to pre-

vent residue remaining in these areas and the extraction wrench must have the torque disabled.3. Submerge the instruments in an ultrasonic bath of a solution of neutral detergent at the correct concentration,

temperature and time, following the manufacturer’s instructions. Ensure the ultrasonic cleaning is suitable for the instruments that are going to be cleaned and that they are not touching each other inside the bath.

4. Remove the instruments from the bath, brush them again and rinse with distilled water.5. Visually verify that there is no residue. If there is, start the process again.6. Once clean, submerge the instruments in a container filled with a disinfectant solution according to the manu-

facturer’s instructions. Ensure all the instruments are submerged and are not touching each other.7. After the recommended time, remove the instruments and rinse with distilled water.8. Dry the instruments with filtered compressed air until it is completely dry.9. Lubricate and assemble the material (if necessary). We recommend you do not use silicone or oil-based lubri-

cants as they inhibit subsequent sterilisation processes.

STAGES OF THE PROCEDURE

BTI recommendations:- Consult the Indications for Use of each product.- Use protective gloves.- Clean after every surgical use.- Do not clean different materials at the same time (aluminium, stainless steel, etc.)

Page 127: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 127 |

REPROCESSING REUSABLE INSTRUMENTS

AUTOMATIC CLEANING AND DISINFECTION

Use always a washer-disinfector certified in accordance with ISO 15883.

1. Disassemble the instruments (if applicable); callipers and others instruments with joints must be opened to prevent residue remaining in these areas and the extraction wrench must have the torque disabled.

2. Place the instruments in the washer-disinfector according to the manufacturer’s instructions. Hinged instruments must be open and those with cannulas must allow water to pass through.

3. Add a neutral detergent, according to the manufacturer’s instructions, and select a suitable programme for the cleaning and final rinse.

4. After cleaning, proceed to thermal disinfection: 10 minutes at 80ºC.5. Dry the instruments with filtered compressed air until it is completely dry.6. Lubricate and assemble the material (if necessary). We recommend you do not use silicone or oil-based lubricants

as they inhibit subsequent sterilisation processes

STERILISATION IN AUTOCLAVE

The instruments with catches or joints must never be closed (metal against metal) before the sterilisation process.

The autoclave cycle must be allowed to finish, without interrupting the drying and cooling phase, to avoid the risk of oxidation.

Never use or sterilise rusty instruments.

1. Place the instruments in suitable bag for sterilisation and seal according to the manufacturer’s instructions. Ensure the bag is large enough so there is no areas of stress that could cause the bag to burst and the sterility subsequently to be lost.

2. If you are using the BTI autoclavable boxes to sterilise the instruments, insert them into suitable bags for sterilisation and seal according to the manufacturer’s instructions. Ensure the bag is large enough so there is no areas of stress that could cause the bag to burst and the sterility subsequently to be lost.

3. Insert the bag into a pre-vacuum autoclave with the paper up or to the edges, without exceeding the maximum load indicated by the manufacturer and without stacking.

4. Sterilise at 134ºC for 6 minutes. The indicator on the bag will change colour to show that the sterilisation is correct.5. Once the sterilisation cycle has finished, leave the bags to cool and dry inside the autoclave and then put them away

in a closed, dry place.

Page 128: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 128 |

LIST OF BTI PATENTS

REGISTERED PATENTS

· The design of the BTI implant is protected by the international patent WO9918881.· The PRGF system is protected by the international patent WO0044314.· The implant surface treatment method is protected by the international patent WO0224243.· The design of the BTI implant transporter is protected by the international patent WO0224102.· The set of motorised expanders to facilitate the fixation of dental implants is protected by the international patent

WO04019807.· The procedure and tools for drilling at low revolutions without irrigation is protected by the international patent

WO05074816.· The ceramisable post is protected by the utility model number U 200800602.· The Interna connection is protected by the international patent WO06109176.· The narrow dental implant is protected by the international patent WO06084922.· The bone crest expander-compactor is protected by the international patent WO07105063.· The threaded tip that is screwed into the implant is protected by the international patent WO10037875.· The extraction tool for dental implants is protected by the international patent WO09153372.· The wrench for applying a maximum fixed or adjustable torque is protected by the international patent WO10055177.· A preparation procedure for PRGF and the PTD transfer device are protected by the international patent

WO10130851.· The dental implant extraction method is protected by the international patent WO11110703.· The expansion procedure for crestal bone and the implant-expander are protected by the international patent

WO12042071.· The tool for drilling in the sinus elevation procedure is protected by the international patent WO12038563.· The metal structure for prosthesis support is protected by the international patent WO13098433.

Page 129: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 129 |

LIST OF BTI BRANDS

The requested and/or registered trademarks are:

· BTI

· BTI BIOABUTMENT · BTI BIOPILAR · BTI DRILLTECH · BTI SCAN · BTI ASSIST · BTI GEST · BTI ULTRASONIC · CERAMIC-ON · ENDORET · IMPLANT DIALOGUE · INTERNA MEDIUM PLUS · INTERNA UNIVERSAL · INTERNA UNIVERSAL PLUS · MULTI-IM · PLASMATERM H · PRGF · PRGF – ENDORET · PTD · TI-BLACK · TI-GOLDEN · TINY · UNICCA

LIST OF BTI PATENTS

Page 130: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 130 |

INDEX IN ALPHABETICAL ORDER

Aesthetic abutment post 42Additional surgical instruments 104Angled hexagonal torque tips 90Articulated bars for straight Multi-Im® 56Block grafts kit 112BTI Drill-Tech® surgical motor 107BTI Scan® 3 118BTI single-use kits 115BTI Ultrasonic tips kit 109BTI ultrasonic tips kit 108Castable abutment 46Centring devices 80CERAMIC-ON® ceramisable abutment post 40Compactors kit 98Copings on transepithelials 24Cylinder for straight and angled Multi-Im® 58Cylinder for UNIT 60Dalbo transepithelial 62Dynamometric surgical wrench 85Endoret® (PRGF®) technology 117 Components: · System IV Centrifuge · Test tube rack · Plasmaterm H® · Activation recipientExpanded Multi-Im® transepithelial 52Expander and compactor kit 99Expanders kit 98Explantation kit 100Fractured screw recovery kit 102Front cutting drills 77Gold abutment post 34Healing abutment 20Implant mount 83Implant mount connector 81Implants - Technical specifications 7Impression copings 22Interna® applicator extension 84Laboratory analog 26Locator Abutment 62Microimplants for orthodontics 110

CONTENTS PAGES

Page 131: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 131 |

Multi-Im® transepithelial 50Multitorque wrench 88Narrow Implants 8Occlusal registration indicators 24Prosthetic kit 91Protection caps for the Multi-Im® transepithelial 53Provisional aesthetic cylinder 32Provisional titanium Biopilar® 30Provisional titanium cylinder 28Ratchet wrench extension 82Right-angled screwdriver 92Screwdriver tips 93Screwdrivers 87Screws 68Single-use material of the kits 116 Components: · Plasma Transfer Device (PTD2) · Fractionation tubes · PRGF activator · Activating syringe · Extraction tubes · Venojet vacutainerSocket wrenches 93Stripped screw recovery kit 103Surgical boxes and drill holder 73Surgical drills 74Ti-Black surface treatment 69Ti-Golden surface treatment 19Titanium abutment post 36Titanium Biopilar® 38Titanmagnetic abutment 66Tools for the laboratory 54Torque tips 89Transitional Expander Implants 16Trephine drill kit 79Trephine drills 78UCLA gold abutment 44UNIT transepithelial 48Universal implants 10Universal Plus implants 12Wide implants 14

CONTENTS PAGES

INDEX IN ALPHABETICAL ORDER

Page 132: PROSTHETIC SURGICAL CATALOGUE - INTERDENT · 2017-05-15 · | 8 | NARROW IMPLANT Narrow platform Ø 3.5 mm. Interna Connection Externa Connection = Tiny® + More information about

| 132 |

Cat. 010 - ING

- Ed.2 - Rev.0 O

CTOB

ER 2016

BTI APPNEW PRODUCTSiPhone / smartphone versioniPad / Tablets version (Customer Area)

NOTE: consult your distributor for the availability of the product in the different markets.

www.bti-biotechnologyinstitute.com

SubsidiariesUSA1730 Walton RoadSuite 110Blue Bell. PA 19422-1802 · USATel: (1) 215 646 4067Fax: (1) 215 646 [email protected]

UK 870 The CrescentColchester Business Park · ColchesterEssex CO49YQ · Regno UnitoTel: (44) 01206580160Fax: (44) [email protected]

GERMANYMannheimer Str. 1775179 Pforzheim · DeutschlandTel. +49 (0) 7231 428060Fax +49 (0) 7231 [email protected]

ITALYPiazzale Piola, 120131 Milano · ItaliaTel: (39) 02 7060 5067Fax: (39) 02 7063 [email protected]

MEXICO Ejercito Nacional Mexicano 351, 3ACol. Granada Delegación Miguel HidalgoMessico DF · CP 11520 · MessicoTel: (52) 55 52502964Fax: (52) 55 [email protected]

PORTUGALPraça Mouzinho de Albuquerque, 113, 5º4100-359 Porto · PortogalloTel: (351) 22 120 1373 Fax: (351) 22 120 [email protected]

DistributorsCROATIATel: [email protected]

GREECE Tel: +30 210 [email protected]

JAPANTel: 81-(0)[email protected]

LITHUANIATel. +370 5 2136648Tel. +370 652 [email protected]

ROMANIA Tel:(40)769 059 [email protected]

RUSSIAТel. +7 [email protected]

UKRAINEТel. +380 (73) 031 31 [email protected]

BELARUSТel.: (+8) 232 41 00 [email protected]

COLOMBIATel: +57 (316) [email protected]

MORROCOТel.: +212 661 880 [email protected]

TAIWANТel.: [email protected]

BTI ComercialSan Antonio, 15 · 5º01005 Vitoria-Gasteiz (Álava) · SPAINTel: +34 945 140 024Fax: +34 945 135 [email protected]

B.T.I. Biotechnology Institute S.L. Parque Tecnológico de Álava Leonardo da Vinci ,1401510 Miñano (Álava) [email protected]