1
Rebasing Process of refitting a denture by replacing the denture base material without changing teeth or occlusal relation of the teeth. Relining Procedure used to refit the tissue surface of a denture. This is done by placing a new acrylic “wash” into the denture, duplicating the new form of the oral structures in the mouth. Indications 1. Every Five Years. 2. To increase retention of old dentures (due to recent extractions or alterations to the ridge). 3. Avoids the necessity of remaking them entirely. 4. Persistent fractures. 5. Poor fit. Procedure 1. Trim internal surface from the denture to avoid increasing vertical dimension and allow space for impression material (suggested material PVS Monophase, tissue conditioner or Polyether), apply adhesive and take a wash impression. 2. Before the material sets, ensure the patient is in centric occlusion (have patient bite while the material sets). 3. Remove and disinfect the impression. 4. Send to Prodenco. Flange Fracture If you have the broken piece, glue (Krazy Glue) it and verify the fit in the patient’s mouth and send it to Prodenco. If a new piece is necessary, take an impression with the appliance in place. 1. Allow for appropriate setting time of material, then remove impression from the mouth keeping the partial in the impression. 2. Pour immediately or send it to Prodenco according to the materials instructions (different materials working/pour-up times vary, see instructions). Midline Fracture If the fracture has a clean break, glue (Krazy Glue) the pieces together, verifying the fit in the patient’s mouth. Send to Prodenco. Cracks Send to Prodenco as is. Replace Lost Tooth Send the appliance to Prodenco along with the tooth if available. Add Additional Tooth to an Existing Partial Take an impression with the partial in place and remove prosthesis from the mouth, keeping the partial in the impression and send it to Prodenco along with the opposing arch, bite registration and shade if necessary. Cu-Sil (Gasket Replacement) 1. Remove the old Cu-Sil. 2. Place the denture into the mouth and inject the impression material around the tooth (use light body or Monophase material). 3. Ensure that the material replicates the space left for the Cu-Sil and the entire surface of the abutment teeth. Cu-Sil Reline 1. Remove all Cu-Sil. 2. Trim the internal surface from the denture to avoid increasing the vertical dimen- sion and allow space for the impression material (use PVS Monophase or Polyether), apply adhesive and take a wash impression. 3. Ensure that the material replicates the space left for the Cu-Sil and the entire sur- face of the abutment teeth. Broken Clasp Or Major Conector 1. Take the impression with the partial in place. 2. After proper setting time, remove the impression keeping the partial in the impression. 3. Pour immediately or send it to Prodenco according to material instructions. 4. If you have the clasp, send it along with the partial still in the impression. Partial Denture Refit Take an impression with-out the partial in place, send the impression or model along with the partial to Prodenco. Crown Under Partial Take an impression with the partial in place. After proper setting time, remove the impression keeping the partial in the impression. If the margins are not captured, take another impression without the par- tial in place, for adaptation of crowns and margins. Send both impressions to Prodenco along with an opposing impression/model and a bite registration. It is recommend that we have the partial in the laboratory for the entire time it takes to fabricate the crown. If that is not possible please contact us for alter- native arrangements. Porcelain Fracture On PFM or Bridge 1. If occurred during seating, send crown, impression and all model work back to Prodenco. 2. If occurs on existing or previously seated crown, and making a new crown is not possible, it is recommended to try using a porcelain repair kit. Rebasing/Relining Dentures Indications 1. Every Five Years 2. Avoids the necessity of remaking them entirely. 3. Poor fit. Procedure 1. Trim internal surface from the partial to avoid increasing vertical dimension and allow space for impression material (suggested material PVS Monophase, tissue conditioner or Polyether), apply adhesive and take a wash impression. 2. Once the wash material sets. Take an impression over the partial in place. 3. Allow for appropriate setting time of material, then remove impression from the mouth keeping the partial in the impression. 4. Pour immediately or send it to Prodenco according to the materials instructions (different materials working/pour-up times vary, see instructions). 5. Take and send opposing arch and bite registration along with pick-up impression. Partials Acrylic Repairs Cast Partial Repairs Crown & Bridge PROSTHETIC REPAIR IMPRESSION GUIDE Billings Dental Laboratories 6108 Maple St. P.O. Box 4258 Omaha, NE 68104 402-551-5954 1-800-747-5441 Jaeger Dental Company 2218 West 2nd Street P.O. Box 4908 Grand Island, NE 68802 308-382-0235 1-800-289-3525 Professional Dental Company 611 Omaha Street P.O. Box 1257 Sioux City, IA 51102 712-252-4034 1-800-831-0936

PROSTHETIC REPAIR IMPRESSION GUIDE - premium … · Process of refitting a denture by replacing the denture base ... keeping the partial in the impressionand send it to ... PROSTHETIC

Embed Size (px)

Citation preview

Page 1: PROSTHETIC REPAIR IMPRESSION GUIDE - premium … · Process of refitting a denture by replacing the denture base ... keeping the partial in the impressionand send it to ... PROSTHETIC

RebasingProcess of refitting a denture by replacing the denture base material without changingteeth or occlusal relation of the teeth.

ReliningProcedure used to refit the tissue surface of a denture. This is done by placing a newacrylic “wash” into the denture, duplicating the new form of the oral structures in themouth.

Indications1. Every Five Years.2. To increase retention of old

dentures (due to recent extractions or alterations to the ridge).3. Avoids the necessity of remaking them entirely.4. Persistent fractures.5. Poor fit.

Procedure1. Trim internal surface from the denture to avoid increasing vertical dimension

and allow space for impression material (suggested material PVS Monophase,tissue conditioner or Polyether), apply adhesive and take a wash impression.

2. Before the material sets, ensure the patient is in centric occlusion (have patientbite while the material sets).

3. Remove and disinfect the impression.4. Send to Prodenco.

Flange Fracture If you have the broken piece, glue (Krazy Glue)it and verify the fit in the patient’s mouth and sendit to Prodenco.

If a new piece is necessary, take an impressionwith the appliance in place.1. Allow for appropriate setting time of

material, then remove impression from themouth keeping the partial in the impression.

2. Pour immediately or send it to Prodencoaccording to the materials instructions (different materials working/pour-up timesvary, see instructions).

Midline Fracture If the fracture has a clean break, glue (Krazy Glue) the pieces together, verifyingthe fit in the patient’s mouth. Send to Prodenco.

CracksSend to Prodenco as is.

Replace Lost ToothSend the appliance to Prodenco along withthe tooth if available.

Add Additional Tooth toan Existing PartialTake an impression with the partial in place and remove prosthesis from the mouth,keeping the partial in the impression and send it to Prodenco along with theopposing arch, bite registration and shade if necessary.

Cu-Sil (Gasket Replacement)1. Remove the old Cu-Sil.2. Place the denture into the mouth and inject the impression material around the

tooth (use light body or Monophase material).3. Ensure that the material replicates the space left for the Cu-Sil and the entire

surface of the abutment teeth.

Cu-Sil Reline1. Remove all Cu-Sil.2. Trim the internal surface from the denture to avoid increasing the vertical dimen-

sion and allow space for the impression material (use PVS Monophase orPolyether), apply adhesive and take a wash impression.

3. Ensure that the material replicates the space left for the Cu-Sil and the entire sur-face of the abutment teeth.

Broken Clasp Or Major Conector1. Take the impression with the partial in place.2. After proper setting time, remove the impression keeping the partial in the

impression.3. Pour immediately or send it to Prodenco according to material instructions.4. If you have the clasp, send it along with the partial still in the impression.

Partial Denture RefitTake an impression with-out the partial in place, send the impression or modelalong with the partial to Prodenco.

Crown Under Partial• Take an impression with the partial

in place. After proper setting time,remove the impression keeping thepartial in the impression. If themargins are not captured, takeanother impression without the par-tial in place, for adaptation ofcrowns and margins. Send bothimpressions to Prodenco alongwith an opposing impression/model and a bite registration.

• It is recommend that we have the partial in the laboratory for the entire time ittakes to fabricate the crown. If that is not possible please contact us for alter-native arrangements.

Porcelain Fracture On PFM or Bridge1. If occurred during seating, send crown,

impression and all model work back toProdenco.

2. If occurs on existing or previously seatedcrown, and making a new crown is notpossible, it is recommended to try using aporcelain repair kit.

Rebasing/Relining

Dentures

Indications1. Every Five Years2. Avoids the necessity of remaking them entirely.3. Poor fit.

Procedure1. Trim internal surface from the partial to avoid

increasing vertical dimension and allow spacefor impression material (suggested materialPVS Monophase, tissue conditioner orPolyether), apply adhesive and take a washimpression.

2. Once the wash material sets. Take an impression over the partial in place.3. Allow for appropriate setting time of material, then remove impression from the

mouth keeping the partial in the impression.4. Pour immediately or send it to Prodenco according to the materials instructions

(different materials working/pour-up times vary, see instructions).5. Take and send opposing arch and bite registration along with pick-up impression.

Partials

Acrylic Repairs Cast Partial Repairs

Crown & Bridge

PROSTHETIC REPAIR IMPRESSION GUIDE

Billings Dental Laboratories6108 Maple St.P.O. Box 4258

Omaha, NE 68104402-551-5954 1-800-747-5441

Jaeger Dental Company2218 West 2nd Street

P.O. Box 4908Grand Island, NE 68802

308-382-0235 1-800-289-3525

Professional Dental Company611 Omaha Street

P.O. Box 1257Sioux City, IA 51102

712-252-4034 1-800-831-0936