Upload
shel
View
29
Download
0
Tags:
Embed Size (px)
DESCRIPTION
Proposal of new optic elements. G. Chadzitaskos Department of Physics, FNSPE, C zech T echnical U niversity in Prague. Stará Lesná 2012. Overview. Two diffraction grating Parabolic strip telescope Objective for X ray microscopy CNOT on polarizated states of light - PowerPoint PPT Presentation
Citation preview
Proposal of new optic elements
G. ChadzitaskosDepartment of Physics, FNSPE, Czech Technical University in
Prague
Stará Lesná 2012
Overview
Two diffraction grating Parabolic strip telescope Objective for X ray microscopy CNOT on polarizated states of light Objective for X ray telescope
Two diffraction systém(Wikipedia)
.
Two diffraction system
The light from monochromatic light source 1 is divided into two channels 3, by a 1:1 beam splitter 2, and is brought into the two-diffraction gratings 5. Two-diffraction grating generally consists of a large number of equally spaced slits, which allows connection of one channel with odd slits and the other channel with even slits 4. Then spots 7 – interference maxima – appear on the screen 6.
Maxima
case 1 :
d
kk 2
sin
case 2:
d
kk
sin
2
0
sinsin
sinsin
sin
sinsin
)(
ba
ban
a
a
II
Intensities
2
0
sin2
sin
sin2
sin
sin
sinsin1
ba
ban
a
a
Ip
2
0
sinsin
sinsin
sin
sinsin)(
ba
ban
a
a
pII
Exploitation
• Measurement of coincident part of light• Measurement of cross sections of interaction
light and electrons (two slit experiment)
CNOT ON POLARIZATED STATES OF COHERENT LIGHT
Optical activity of molecules with magnetic dipole
(C.Denz,Electro-optic composite polymers, Munster)
Linear dependence on electric field
CEkT
npP
2
2
Exploitation
• Quantum optics
PARABOLIC STRIP TELESCOPEPrinciple
Rotation around y axis and Radon inverse transform
Used experimental plexiglass telescope objectives
Artifitial constelations
Image procesing
From camera RGB uint8 Select central part, make
matrices 600 x 600x 3 and rotate, single precision
12th root of real matrices Point multiplication of 0
and 90 degree matrices Point multiplication,
optimalization Uint8 and image
Images of artificial star constellation
Original images at 0, 45, 90, and 135 degree
After MATLAB calculation
Image procesing
Advantages \• good angular resolution• low expenses• simple technological development• simple exploitation of adaptive optics• possibility to install a net of large telescopes over the Earth• lower weight for use on satellites
Proposal: Over Earth net of telescopes (30 degrees)
• high mounting not necessary• low wind influence• low gravitational influence
Objective for X ray microscopy
Fresnel zone plates, polycapillar optics, Goebel mirrors, biconcave refractive optics.
New: Spatial grating – Bragg’s and interference conditions
.
Example
12
1
22
0
sRRd
nE
FS
1
222
000
0 sRdR
nESF
sin2dn 22sin
sR
R
X ray telescope
Wolter Kirkpatrick-Baez
Lobster eye objective
New X-ray telescope
Bragg’s condition
22
2px
p
nd
)1(0 Tdd
1
2
1)()( 22
0min px
pd
nxTxT
222
0
222max
2min
2max
44
ndnd
xx
Děkuji za pozornost
Pro destičku germaniového monokrystalu a teploty mezi 250 a 1000 K je pro vlnovou délku 0.5 nm hodnota například pro xmin = 10 cm bude xmax = 10,8 cm.