27
Pro/INTRALINK Data Migrator Migrating from 3.x to 8.0 Steve Shaw Product Manager

Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

Pro/INTRALINK Data MigratorMigrating from 3.x to 8.0

Steve ShawProduct Manager

Page 2: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC2

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 3: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC3

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 4: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC4

2004 – CAD Data Management Customers Must Compromise

Pro/INTRALINK 3.X

Strengths:Full Pro/E Workgroup Level Data Management Functionality

LAN Performance

Customer Already Owns

Weaknesses:Enterprise Capabilities

WAN Performance

Extended Enterprise Access

Multiple Client UI’s

Windchill 7.0

Strengths:Enterprise Capabilities

WAN Performance

Modern Architecture (Scalability, Security, Integration)

Single Client UI

Weaknesses:Full Pro/E Workgroup Level Data Management Functionality

LAN Performance

Upgrade Path from Pro/I 3.X Costly

Page 5: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC5

2005 – Eliminating the Compromise

Strengths:Full Pro/E Workgroup Level Data Management Functionality

LAN Performance

Customer Already Owns

Weaknesses:Enterprise Capabilities

WAN Performance

Extended Enterprise Access

Multiple Client UI’s

Strengths:Enterprise Capabilities

WAN Performance

Modern Architecture (Scalability, Security, Integration)

Single Client UI

Weaknesses:Full Pro/E Workgroup Level Data Management Functionality

LAN Performance

Upgrade Path from Pro/I 3.X Costly

Pro/INTRALINK 8.0 – A Single Solution withModular Packaging to Eliminate Compromises

Page 6: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC6

Pro/INTRALINK 3.x Customers Have Multiple Options

Windchill PDMLink 8.0

Pro/INTRALINK 8.0

All of the capabilities of Pro/INTRALINK, plus: multi-MCAD / ECAD, CMII change management, advanced configuration management, turnkeyBest to obtain all the benefits of the PDSERP integration, etc.One solution for workgroup and enterprise PDMRequires purchasing licensing upgrade package Option to add Light user pricingRobust migration capabilities and training support

Next generation Pro/ENGINEER workgroup data management Modern Windchill architectureSimple starting point with growth potentialIncluded with Pro/INTRALINK maintenanceRobust migration capabilities and training support

A

B

Page 7: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC7

Differences Between Pro/INTRALINK & Windchill PDMLink

Pro/INTRALINK 3.x

Pro/E versioning & vaultingWorkgroup collaborationBasic lifecycle mgmt (simple release)Basic document mgmtBasic configuration mgmt (baselines)Content replication (multi-site version)Basic visualization Optional advanced visualizationBasic searchBOM/ Relationship reporting

Pro/INTRALINK 8.0

Improved distributed (WAN) performanceNew Web-based architecture

Streamlined Pro/ENGINEER Wildfire interactionsExpanded visualizationScalabilityAdvanced security/ firewall/ LDAP Eliminates client installationsCross-locale support

Additional capabilitiesEnhanced document mgmtImproved Difference ReportingExpanded History Reporting

Rename historySave As historyLocation history

Optional Archive module

Select non-core functionality planned for next releases

Windchill PDMLink 8.0

Complete product definitionAbility to add 3rd party MCAD and ECAD integrations Define and manage enterprise BOMAdvanced structure/ configuration managementImproved document management (MS Office integration, structured docs)

Engineering change managementProcess automation/ workflowExpanded visualization

Additional object adapter supportIncl. Lite visualizationECAD validation with InterComm

Enterprise user (light) seatsAbility to add Windchill ProjectLink

Product development collaboration Project management and execution

Optional modulesClassification and reuseEnterprise system integrations (e.g, SAP)Adobe PDF integration

Page 8: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC8

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 9: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC9

Introducing the Pro/INTRALINK Data Migrator

Enables migration from Pro/INTRALINK 3.x to the 8.0 architecture

Key capabilities

Consolidation of multiple Pro/INTRALINK instances Out of the box support for all Pro/ENGINEER file typesMigration of non-Pro/ENGINEER data currently managed in Pro/INTRALINKPreservation of the history of migrated dataWorks with a pre-populated target systemOptional part and product structure initialization

Benefits

Increased reuse with system consolidationSimplified system administrationImprove product development in a dist. env.

Windchill PDMLink 8.0 orPro/INTRALINK 8.0

Pro/INTRALINK Data Migrator

Pro/INTRALINK 3.3 or 3.4

Pro/INTRALINK 3.3 or 3.4

Pro/INTRALINK 3.3 or 3.4

Page 10: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC10

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 11: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC11

Supported data

Administrative DataUsers

Attribute definitions

Folder structure

All Object TypesBoth Pro/E and Non-Pro/E data

Maintain revision/version history

Main branch data only

File content

Relationships

ConfigurationsNamed baselines

As-stored transaction IDs

Object Maturity

Attribute ValuesUser defined

System attributes

FormsCompleted RTP Forms

Check-in Form Comments

Rename History

Page 12: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC12

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 13: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC13

How it works

Command line driven

Page 14: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC14

How it works

Controlled by host of editable mapping files

Page 15: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC15

How it works

Pro/INTRALINK Data Migrator

Windchill PDMLink 8.0 orPro/INTRALINK 8.0

Pro/INTRALINK 3.3 or 3.4

Database database when possible

Avoiding MS business logic = performanceWorks independently against software objectsMigration not complete until last object has migrated

Page 16: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC16

How it works

Step 4: Initiate MigrationDocumentFTLinkUDABaselineAsStoredRTPFormRenameHistoryFileTransferPartBuildProcess

Step 5: Migrated data available in targetUnhideUsable by non-administrative users

Step 1: Load Administrative DataUsers

Folders

Attribute definitions

Step 2: Establish and Load Mapping

Step 3: Conflict HandlingCheck for conflicts

Prescribe resolution

Zero conflict state required to continue

Migrates entire Pro/INTRALINK Database (no partial migrations)

Page 17: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC17

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 18: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC18

Successes – Proving the technology

Pro/INTRALINK Data Migrator

Windchill PDMLink 7.0

Pro/INTRALINK 3.3

Customers are migrating today

7 Production accounts

• Europe & North America

• Small & large

8 Pre-production accounts

• Actively working through the Testing phase

• Production slated for Q2-3

Pipeline growth continues• 8.0 customers lining up

PTC Global Service led engagements

Current 7.0 Migration Activities

Page 19: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC19

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 20: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC20

Performance sample

Pro/INTRALINK 3.3 Statistics Migration Processing Times

DATA TYPE SIZE

Oracle dump file 2.9GB

PI 441662

PIV 1454047

Attributes (V, NV, LC) 20

Dependency Attributes None

Family Table Contained in Links 1048752

Dependencies 8734573

Named Baseline 25

AsStored Transaction IDs 93507

Page 21: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC21

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 22: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC22

Support information

Pro/INTRALINK 8.0 PDMLink 8.0 Windchill Foundation 8.0

Pro/INTRALINK 2.0 – 3.3 M0101

Pro/INTRALINK 3.3 M02x

Pro/INTRALINK 3.4

UPGRADE

UPG

RA

DE

Software Compatibility

OS SupportWindows Server 2003SUN Solaris 9HP-UX 11i

Language SupportNot localizedSupports all certified Pro/INTRALINK Languages

Page 23: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC23

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 24: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC24

Migration paths

It’s more than just moving data

People

Processes

Data is the easy part

Engage PTC Global ServicesTime and materials depending upon customer size and complexity

Certified Migration PartnersSet of VARs will be trained and certified as migration experts

Perform the migration in-houseSoftware general availability Oct. 2005

• Free for Pro/INTRALINK customers on active maintenance

• Training prerequisite removed

Prior to Oct. 2005 training required• Attend training get early access to Migrator

Training course• Migration tool training (2 days)• Administrative training (3 days)

PTC Services Health-checks• Available as separate purchase• Provides access to PTC migration experts

Customer trainingPlanning

Conflict identification

Conflict resolution

Rehearsal migration

Migration roadmap

Production migration

Page 25: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC25

Agenda

Evolution of Pro/INTRALINK 8.0

Introducing the Pro/INTRALINK Data Migrator

Supported data

How it works

Early success

Performance

Support information

Software availability

Available resources

Page 26: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration

© 2005 PTC26

www.PTC.com/go/ProINTRALINK

Community web site for current Pro/INTRALINK customers

Your central on-line resource to help you plan and make the moveExperts who can provide advice about making the move to the new release Discussion forums to communicate with experts and other users

Find tips and resources to help you in:

Getting startedInstallingMigrating dataAdministering the systemLearningFinding additional resources

Page 27: Pro/INTRALINK Data Migrator Migrating from 3.x to 8windchill.datajett.com/ProI3-8/31580en_file1.pdf · 2006-09-05 · Introducing the Pro/INTRALINK Data Migrator Enables migration