ProfibusProfibus
PLC
PROFIBUS
active stations, master devices
Drive Actuator Transmitter
passive stations, slave devices
Sensor Sensor Drive
logical token ring between the master stations
Sensor
M M T
PLCPLC
PROFIBUS - Token Ring
Device Data Base FilesGSD-file
Profimap PROFIBUS configuration tool
System configuration
PLC
Fielddevice
I/O Sensor Drive
MTrans-mitter
Fielddevice
PROFIBUS - DP
Open Configuration with PROFIMAP
Device Data Base FilesGSD-file
PROFIBUS configuration tool
System configuration
Fielddevice
I/O Sensor Drive
MTrans-mitter
Fielddevice
PROFIBUS - DP
PC Based Control
Open Configuration with PC Based Control
Bus TerminatorResistance
A1SJ71PB92D
Mode
RS-232-C
ProfibusI/F
Bus Termination
On Off
################
################
######
ProfiMap Cable
To Profibus DPNetwork
Melsec ProfiMapConfiguration Software
Mode Selection
– 0 = On-Line *
– 1 = PRM Set
– 2 = Test
– E = Online #
* 32 I/O byte mode
#244 I/O byte mode
(version BE or later)
A1SJ71PB92D Module Details Hardware Configuration
AJ71PB92D
Mode
RS-422
ProfibusI/F
Bus Termination
On Off
################
################
######
To Profibus DPNetwork
Melsec Profimap Ver 2.0 up
Mode Selection
– 0 = On-Line *
– 1 = PRM Set
– 2 = Test
– E = Online #
* 32 I/O byte mode
#244 I/O byte mode
Bus TerminatorResistance
ProfiMap Cable
AJ71PB92D Module DetailsHardware Configuration
DP Master Module ConfigurationHas the capability to support 60 Slave UnitsEach Slave can address 32 Bytes Input Data / 32 Bytes Output DataExtended capacity up to 244 I/O bytes * per slaveDiagnostic Area for Slave fault InformationDiagnostic Buffer for master module faultsOn-Board Termination resistorSupports Global Functions
* On AnS module versions BE or later, all AJ71PB92D versions
ProfiMap Configuration Software
Many devices can be added, as shown
The “Create POU” button is a direct link to MM+
A POU is created as an ascii file
Page 118
The ascii file can be imported from theProject menu, as shown.
Page 119
A POU has been created, in Melsec IL, containing, TO/FROM statements, for allstations on the Profibus network. Buffer memory is allocated in ascending stationnumber order.
The information filledin at this stage, are thesource/destination forthe TO/FROM instructions in the POU.
Mitsubishi and Profibus DP Mitsubishi have the following devices that support the Profibus DP Protocol:
– FX0N/FX2N PLC with FX0N-32NT-DP add on block– FX2N-32DP-IF I/O adaptor interface – E range of Operator Interfaces– FR-PBM Inverter Drive Interface (A024/A044/A140/A240)– A500 Inverter Drives (with FR-A5NP interface)– Remote I/O AJ95TB3-16D 16 way input– AJ95TB2-16T 16 way trans output– AJ95TB32-16DT 8 way input / 8 way output– MT Series I/O digital and analogue I/O
3 8
Profibus I/F 9 PinA(1S)J71PB92DMaster Module
FR-PBM
3 8 3 8
..
..
3 8
..
MAC E range + IFC PBDP
Profibus DP
RS422/485
Mitsubishi Profibus DP Connections
DigitalRemote
I/O
3 8
..
FX0N/FX2N PLC+
FX0N-32NT-DP
Up to 32 Nodes per Master Module without repeaters
Pr 7
1 2 34 5 67 8 9
FR - PU02E
3 8
..
Pr 7
1 2 34 5 67 8 9
FR - PU02E
A024/A044A140/A240 Drives
A500 Drives+
FR-A5NP
Earthing not shown see earlier slides
Remote I/OFX2N32DP-IF
+standard I/O,
analogue,high speed I/P
Blocks
3 8
..
3 8
..
Digital/AnalogueRemote
I/O
Remote I/OAJ95TB3-16D 16 way inputAJ95TB2-16T 16 way transistor outputAJ95TB32-16DT 8 way input / 8 way output
Fixed Digital I/O Blocks
Mitsubishi I/O Options
MT Series Flexible I/O Blocks
Base Module - 16 modules (up to 8 analogues) can be connected
Digital Module - 8/16 inputs and 4/8/16 outputs are available. Outputs in relay or transistor types
Analogue Module - 4 inputs and 4 outputs are available. 12 bit resolution
Mitsubishi I/O Options
FX2N 32DP-IF - Interface Solution
FX2N 32DP-IF allows standard FX0N/2N extension blocksto be coupled together as a Profibus DP I/O station
FX2N 16/32/48 Digital I/O blocksFX0N 8/16 Digital I/O blocksFX2N 4DA/AD 4 channel analogue output/input blocksFX2N 4AD-PT 4 channel PT100 sensor inputFX2N 4AD-TC 4 channel thermocouple input
Standard FX blocks can be used with an adapter cable
Mitsubishi I/O Options
Questions?