Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Embed Size (px)

Citation preview

Page 1: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

ProfibusProfibus

Page 2: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

PLC

PROFIBUS

active stations, master devices

Drive Actuator Transmitter

passive stations, slave devices

Sensor Sensor Drive

logical token ring between the master stations

Sensor

M M T

PLCPLC

PROFIBUS - Token Ring

Page 3: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Device Data Base FilesGSD-file

Profimap PROFIBUS configuration tool

System configuration

PLC

Fielddevice

I/O Sensor Drive

MTrans-mitter

Fielddevice

PROFIBUS - DP

Open Configuration with PROFIMAP

Page 4: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Device Data Base FilesGSD-file

PROFIBUS configuration tool

System configuration

Fielddevice

I/O Sensor Drive

MTrans-mitter

Fielddevice

PROFIBUS - DP

PC Based Control

Open Configuration with PC Based Control

Page 5: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Bus TerminatorResistance

A1SJ71PB92D

Mode

RS-232-C

ProfibusI/F

Bus Termination

On Off

################

################

######

ProfiMap Cable

To Profibus DPNetwork

Melsec ProfiMapConfiguration Software

Mode Selection

– 0 = On-Line *

– 1 = PRM Set

– 2 = Test

– E = Online #

* 32 I/O byte mode

#244 I/O byte mode

(version BE or later)

A1SJ71PB92D Module Details Hardware Configuration

Page 6: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

AJ71PB92D

Mode

RS-422

ProfibusI/F

Bus Termination

On Off

################

################

######

To Profibus DPNetwork

Melsec Profimap Ver 2.0 up

Mode Selection

– 0 = On-Line *

– 1 = PRM Set

– 2 = Test

– E = Online #

* 32 I/O byte mode

#244 I/O byte mode

Bus TerminatorResistance

ProfiMap Cable

AJ71PB92D Module DetailsHardware Configuration

Page 7: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

DP Master Module ConfigurationHas the capability to support 60 Slave UnitsEach Slave can address 32 Bytes Input Data / 32 Bytes Output DataExtended capacity up to 244 I/O bytes * per slaveDiagnostic Area for Slave fault InformationDiagnostic Buffer for master module faultsOn-Board Termination resistorSupports Global Functions

* On AnS module versions BE or later, all AJ71PB92D versions

Page 8: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

ProfiMap Configuration Software

Page 9: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Many devices can be added, as shown

Page 10: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

The “Create POU” button is a direct link to MM+

Page 11: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

A POU is created as an ascii file

Page 12: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Page 118

The ascii file can be imported from theProject menu, as shown.

Page 13: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Page 119

A POU has been created, in Melsec IL, containing, TO/FROM statements, for allstations on the Profibus network. Buffer memory is allocated in ascending stationnumber order.

Page 14: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

The information filledin at this stage, are thesource/destination forthe TO/FROM instructions in the POU.

Page 15: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Mitsubishi and Profibus DP Mitsubishi have the following devices that support the Profibus DP Protocol:

– FX0N/FX2N PLC with FX0N-32NT-DP add on block– FX2N-32DP-IF I/O adaptor interface – E range of Operator Interfaces– FR-PBM Inverter Drive Interface (A024/A044/A140/A240)– A500 Inverter Drives (with FR-A5NP interface)– Remote I/O AJ95TB3-16D 16 way input– AJ95TB2-16T 16 way trans output– AJ95TB32-16DT 8 way input / 8 way output– MT Series I/O digital and analogue I/O

Page 16: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

3 8

Profibus I/F 9 PinA(1S)J71PB92DMaster Module

FR-PBM

3 8 3 8

..

..

3 8

..

MAC E range + IFC PBDP

Profibus DP

RS422/485

Mitsubishi Profibus DP Connections

DigitalRemote

I/O

3 8

..

FX0N/FX2N PLC+

FX0N-32NT-DP

Up to 32 Nodes per Master Module without repeaters

Pr 7

1 2 34 5 67 8 9

FR - PU02E

3 8

..

Pr 7

1 2 34 5 67 8 9

FR - PU02E

A024/A044A140/A240 Drives

A500 Drives+

FR-A5NP

Earthing not shown see earlier slides

Remote I/OFX2N32DP-IF

+standard I/O,

analogue,high speed I/P

Blocks

3 8

..

3 8

..

Digital/AnalogueRemote

I/O

Page 17: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Remote I/OAJ95TB3-16D 16 way inputAJ95TB2-16T 16 way transistor outputAJ95TB32-16DT 8 way input / 8 way output

Fixed Digital I/O Blocks

Mitsubishi I/O Options

Page 18: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

MT Series Flexible I/O Blocks

Base Module - 16 modules (up to 8 analogues) can be connected

Digital Module - 8/16 inputs and 4/8/16 outputs are available. Outputs in relay or transistor types

Analogue Module - 4 inputs and 4 outputs are available. 12 bit resolution

Mitsubishi I/O Options

Page 19: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

FX2N 32DP-IF - Interface Solution

FX2N 32DP-IF allows standard FX0N/2N extension blocksto be coupled together as a Profibus DP I/O station

FX2N 16/32/48 Digital I/O blocksFX0N 8/16 Digital I/O blocksFX2N 4DA/AD 4 channel analogue output/input blocksFX2N 4AD-PT 4 channel PT100 sensor inputFX2N 4AD-TC 4 channel thermocouple input

Standard FX blocks can be used with an adapter cable

Mitsubishi I/O Options

Page 20: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

Questions?

Page 21: Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between

ProfibusProfibus