29
Professional Vacuum Systems Accessories Guide

Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

Embed Size (px)

Citation preview

Page 1: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

Professional Vacuum Systems Accessories Guide

Page 2: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

OVERVIEW

About MedelaOver more than 50 years, Medela has developed from a small family owned company in Switzerland to a global producer of the most technologically advanced breastpumps and Medical Vacuum Solutions.  

The Medela Healthcare range of products fulfils international industrial standards: ISO 9001 as well as the American Good Manufacturing Practices guidelines (GMP). Our products also carry the CE label in accordance with the directive 93/42/EEC for medical products.

© Medela UK Ltd. page 2

= ideal = possible

Suction capacity (l/min) Max. consumption (l/min) Max. vacuum (kPa) (mmHg) Medical Suction Systems

Endoscopy Liposuction Obstetrics Ear, nose and throat Gastric Suction

Cardiothoracic Systems

Thoracic Drainage 

Cla

rio

15 

-80 -595

Var

io 8

AC

/DC

/

Var

io 8

c/i

AC

/DC

-9 -68

Var

io 1

8 c/

i AC

/DC

18 

-51 -380

Var

io 1

8 A

C/D

C

18 

-75 -563

Bas

ic

30 

-90 -675

Do

min

ant

Fle

x

Th

op

az

40/50/60 

-95 -713

-10 -75

Patient transfer Emergency Intensive care unit Operating theatre/Surgery Room/Ward Practice Dentist Nursing home 

Application Area

Low vacuum applicationsT

ho

paz

+

Cardiothoracic Drainage 

-10 -75

Page 3: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

TABLE OF CONTENTS

© Medela UK Ltd. page 3

Signs and Symbols

intended to be reprocessed. Reprocessing could cause loss of mechanical, chemical and / or biological characteristics. Reuse could cause cross contamination.

Accessories.............................................................................................................................

VarioReusable sets...........................................................................................................................

Filters.........................................................................................................................................Foot controls............................................................................................................................Clampholders...........................................................................................................................

Liners........................................................................................................................................

p.4

PC jars........................................................................................................................................Patient tubings / Tubings connectors without coupling pieces...........................................

VarioConnectors and tubings............................................................................................................

Patient tubings with 1 coupling piece.........................................................................Patient tubings with 2 coupling pieces..................................................................................Various patient tubings / Tubing connectors.........................................................................

Reusable jars............................................................................................................................2 or more jars............................................................................................................................Specimen cups.......................................................................................................Additional accessories..............................................................................................................Reusable lids..........................................................................................................

p.5 - 7p.7p.8p.9 - 11p.12p.13p.14p.15p.16p.17 - 19p.20 - 21p.22 - 23p.24p.25p.26p.27

Autoclavable, for example at 135°C/10 minutes

Not autoclavable.Cleaning in a cleaning and disinfecting machine

Caution: This is a single use product not

..Medelea UK contact details..................................................................................... p.28

Page 4: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 4

ACCESSORIESArticle Number Description Principle

071.0034 Trolley for Basic/Dominant Flex suction pumps

Pump is attached to the trolley by screws. Trolley has 4 castors with brakes.

InstructionSheet

IFU Use

Integrated in IFU of pumps

To make the pump mobile. Further accessories (max. 4x5 l jars) can be attached to the standard rail.

077.0711 Safety Set for direct connection to pump

Floater rises when fluid reaches a maximum in the jar and shuts off suction.

177.0711 Integrated in IFU of pumps

Serves as overflow protection of the pump.

017.0015 Apgar Timer for standard rail (10 x 25 mm)

Electronics inside the product.200.2336 Beeps every 1, 5, 10 minutes to remind the user to perform the Apgar Test on the newborn.

Page 5: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 5

FILTERSArticle Number Description Principle

077.0092 Disposable overflow protection / bacteria / odour filter with Medela connections

Hydrophobic filter mat with bacterialfiltering properties (Goretex) and active charcoal for odour neutralisation.

InstructionSheet

IFU Use

177.7570 Protects the pump from overflow and bacteria, neutralises odour.

077.0571 Disposable overflow protection /bacteria filter with Medela connections

Hydrophobic filter mat with bacterial filteringproperties (Goretex).

177.7570 Protects the pump from overflowand bacteria.

077.0572 Disposable overflow protection /bacteria filter with conical connections

Hydrophobic filter mat with bacterial filtering properties (Goretex).

177.7570 Protects from overflow and bacteria (is connected between two tubing pieces).

077.0577 Disposable overflow protection /bacteria filter with Medela and conical connections

Hydrophobic filter mat with bacterial filtering properties (Goretex).

177.7570 Protects from overflow and bacteria (is connected to lid of Medela collection systemand tubing).

Page 6: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 6

FILTERSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0573 Disposable bacteria filter with Medela connections

Bacterial filtering mat.177.7570 Protects pump from bacteria.

077.0574 Disposable bacteria filter with conical connections

Bacterial filtering mat.177.7570 Protects from bacteria (is connected between two tubing pieces).

077.0575 Disposable bacteria / odour filter with Medela connections

Bacterial filtering mat and active charcoal for odour neutralisation.

177.7570 Protects pump from bacteria and neutralises odour.

077.0576 Disposable bacteria / odour filterwith conical connections

Bacterial filtering mat and active charcoal for odour neutralisation.

177.7570 Protects from bacteria and neutralises odour (is connectedbetween two tubing pieces).

Page 7: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 7

FILTERSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0582 Disposable particle filter with Medela connections

Filter mat made of 100% cotton to trap larger particles.

177.7570 Traps larger particles to protect pump.

FOOT CONTROLS077.0723 Foot ON / OFF switch Integrated in

IFU of pumpsTurns pump on / off.

Integrated in IFU of pumps

077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of pump.

Leak air principle.

Page 8: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 8

CLAMPHOLDERSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0521 Clampholder, plastic Button is pressed down withspring mechanism to open clamp. Then attached to standard rail.

Integrated in IFU of pumps

Attaches to standard rail and is used to hold accessory products such as jars.

077.0751 Tubing holder, left side Screw is used to fasten holder onto standard rail.

Attaches to standard rail to hold tubing on side of pump.

077.0752 Tubing holder, right side Screw is used to fasten holder onto standard rail.

Attaches to standard rail to hold tubing on side of pump.

077.0651 Safety Set with clampholder Attaches to standard rail with clampholder. 0.25 l jar + lid and two tubings.

To collect fluids amounts of up to 0.25 l

177.0521

Page 9: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 9

REUSABLE SETSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0701 Reusable 1 l set with PSU suction jar with clampholder

Consists of suction jar + lid + disposable tubing + clampholder. Connects to standard rail with clampholder. Suction tubing frompump can be attached to vacuumport of lid.

To collect secretions.

077.0702 Reusable 2 l set with PSU suction jar with clampholder

Consists of suction jar + lid + disposable tubing + clampholder. Connects to standard rail with clampholder. Suction tubing from pump can be attached to vacuumport of lid.

To collect secretions.

077.0703 Reusable 3 l set with PSU suction jar with clampholder

Consists of suction jar + lid + disposable tubing+ clampholder. Connects to standard rail with clampholder. Suction tubing from pump can be attached to vacuum port of lid.

To collect secretions.

077.0705 Reusable 5 l set with PSU suction jar with clampholder

Consists of suction jar + lid + disposable tubing + clampholder. Connects to standard rail with clampholder. Suction tubing from pump can be attached to vacuum port of lid.

To collect secretions.

177.0701

177.0702

177.0703

177.0705

ÿ  10-14mm

Page 10: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 10

REUSABLE SETSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0707 Double-reusable 2 l set with PSU suction jar with clampholders

Consists of 2 suction jars + lids + disposable tubing + clampholders as well as 1 change-over valve. Connects to standard rail with clampholders. Suction tubing from pump can be attached to change-over valve.

To collect secretions.

077.0704 Double-reusable 3 l set with PSU suction jar with clampholders

Consists of 2 suction jars+ lids + disposable tubing + clampholders as well as 1 change-over valve. Connects to standard rail with clampholders. Suction tubing from pump can be attached to change-over valve.

To collect secretions.

077.0706 Double-reusable 5 l set with PSU suction jar with clampholders

Consists of 2 suction jars + lids + disposable tubing + clampholders as well as 1 change-over valve. Connects to standard rail with clampholders. Suction tubing from pump can be attached to change-over valve.

To collect secretions.

177.0707

177.0704

177.0706

 

ÿ  10-14mm

Page 11: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 11

REUSABLE SETSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0715 Reusable 1 l set with PSU suction jar

Consists of suction jar + lid + disposable tubing. Connects to Vario or portable Basic/Dominant Flex (handle) pumps directly. Suction tubing from pump can be attached to vacuum port of lid.

To collect secretions.

077.0716 Reusable 2 l set with PSU suction jar

Consists of suction jar + lid + disposable tubing. Connects to portable Basic/Dominant Flex (handle) pumps directly. Suction tubing from pump can be attached to vacuum port of lid.

To collect secretions.

177.0715

177.0716

Page 12: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 12

LINERSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0083 Disposable suction liner 1.5 l Disposable liner that is placed into PC jar. Suction is attached to PC jar. Patient tubing connector on liner.

200.1783 To collect secretions.

077.0084 Disposable suction liner 1.5 l with solidifier

Disposable liner that is placed into PC jar. Suction is attached to PC jar. Patient tubing connector on liner. Solidifier hardens contents, so liner can be disposed of as solid waste.

To collect secretions. Contains solidifier to solidify suctioned fluids.

077.0086 Disposable suction liner 2.5 l Disposable liner that is placed into PC jar. Suction is attached to PC jar. Patient tubing connector on liner.

To collect secretions.

077.0087 Disposable suction liner 2.5 l with solidifier

Disposable liner that is placed into PC jar. Suction is attached to PC jar. Patient tubing connector on liner. Solidifier hardens contents, so liner can be disposed of as solid waste.

To collect secretions. Contains solidifier to solidify suctioned fluids.

200.1783

200.1783

200.1783

Page 13: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 13

PC JARSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0082 Suction jar PC, 1.5 l Suction source is attached to PC jar. Holds disposable liner.

077.0085 Suction jar PC, 2.5 l Suction source is attached to PC jar. Holds disposable liner.

200.1783

200.1783

Page 14: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 14

PATIENT TUBINGS / TUBING CONNECTORS WITHOUT COUPLING PIECESArticle Number Description PrincipleInstruction

SheetIFU Use

077.0900 Silicone tubing Ø 7 x 12 mm, w/o coupling pieces, 25 m

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions.

077.0901 Silicone tubing Ø 7 x 12 mm, w/o coupling pieces 1 m

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions.

077.0902 Silicone tubing Ø 7 x 12 mm, w/o coupling pieces, 2 m

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions.

077.0905 Silicone tubing Ø 7 x 12 mm, w/o coupling pieces, 5 m

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions.

Page 15: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 15

PATIENT TUBINGS / TUBING CONNECTORS WITH 1 COUPLING PIECEArticle Number Description PrincipleInstruction

SheetIFU Use

077.0912 Silicone tubing Ø 7 x 12 mm with 1 coupling piece, 60 cm

For use with Vario, Basic, Dominant.Connects pump to: e.g. y-piece for vacuum connection (serial, DCS) or can be used when coupling piece already existing.

077.0913 Silicone tubing Ø 7 x 12 mm with 1 coupling piece, 100 cm

For use with Vario, Basic, Dominant.Connects pump to: e.g. y-piece for vacuum connection (serial, DCS) or can be used when coupling piece already existing.

077.0961 Silicone tubing, green Ø 6.5 x 12.5 mm 180 cm with coupling piece

For use with Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions. Mainly used when suctioned fluids may irritate an awake person (e.g. obstetrics).

Page 16: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 16

PATIENT TUBINGS / TUBING CONNECTORS WITH 2 COUPLING PIECESArticle Number Description PrincipleInstruction

SheetIFU Use

077.0921 Silicone tubing Ø 7 x 12 mm with 2 coupling pieces, 30 cm

For use with Basic, DominantConnects pump (Safety Set) to lid of reusable system or liner (disposable system).

077.0922 Silicone tubing Ø 7 x 12 mm with 2 coupling pieces, 60 cm

For use with Basic, Dominant.Connects e.g. Safety Set to lid of reusable system or liner (disposable system).

077.0931 Silicone tubing Ø 7 x 12 mm, 25 cm, with 1 coupling piece and 1 coupling piece 90 °

For use with Vario.Connects pump (Safety Set) to lid of reusable system or liner (disposable system).

077.0185 Silicone tubing Ø 7 x 12 mm, 60 cm, with 1 coupling piece and 1 coupling piece 90 °

For use with Basic, Dominant.Connects pump (Safety Set) to lid of reusable system or liner (disposable system).

Page 17: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 17

VARIOUS PATIENT TUBINGS / TUBING CONNECTORS Article Number Description PrincipleInstruction

SheetIFU Use

077.0970 Silicone tubing Ø 5 x 10 mm, 25 m

For use with Basic, Dominant.Connects to patient connection on lids of reusable system (077.0460) or liners (without angle piece - disposable system) for suctioning secretions.

077.0951 Disposable (PVC) tubing, 180 cm, with fingertip, sterile

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions. Fingertip helps user adjust vacuum strength.

077.0963 PVC tubing Ø 12.7 x 18 mm, 200 cm for patient connection Ø 10-14 mm

For use with Basic, Dominant.Connects to patient connection on lids of reusable system (077.0460) or liners (without angle piece - disposable system) for suctioning secretions. Disposable.

077.0965 Disposable PVC tubing, 150 cm CH 25, sterile

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions. Can be used to attach catheters with male coupling.

Page 18: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 18

VARIOUS PATIENT TUBINGS / TUBING CONNECTORS Article Number Description PrincipleInstruction

SheetIFU Use

077.0184 Disposable PVC tubing, with two connectors, for Bird Cups, 150 cm, CH25, sterile

For use with Basic, Dominant.For attaching Bird Cups to lid or liner.

077.0170 Disposable PVC tubing Ø 6.9 x 10 mm, for Malmström and Silc Suction Cups, 150 cm, sterile

For use with Basic, Dominant.For attaching Malmström and Silc Cups to lid or liner, disposable.

077.0055 Silicone tubing Ø 6.5 x 11.5 mm, 120 cm, for Malmström Suction Cups (handle to pump attachment)

For use with Basic, Dominant.For attaching Malmström Cups to lid or liner.

077.0053 Silicone tubing, Ø 6.5 x 11.5 mm, 32 cm, for Malmström Suction Cups (cup to handle attachment)

For use with Basic, Dominant.For attachment from Malmström Suction Cups to handle.

Page 19: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 19

VARIOUS PATIENT TUBINGS / TUBING CONNECTORS Article Number Description PrincipleInstruction

SheetIFU Use

077.0056 Silicone tubing Ø 6.5 x 11.5 mm,150 cm, for Bird and Silc Cup

For use with Basic, Dominant.For attaching Bird and Silc Cups to lid or liner, autoclavable.

077.0051 Silicone tubing Ø 6.5 x 11.5 mm, 200 cm, for CaesAid Cup

For use with Basic, Dominant.For attaching CaesAid Cup to lid or liner, autoclavable.

077.0052 Silicone tubing Ø 6.5 x 11.5 mm,by the meter, roll of 25 m

For use with Vario, Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions, can be cut to desired length.

077.0164 Silicone tubing Ø 6.5 x 11.5 mm, 300 cm

For use with Basic, Dominant.Connects to patient connection on lids of reusable system or liners (disposable system) for suctioning secretions, extra long at 3m.

Page 20: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 20

CONNECTORS & TUBINGSArticle Number Description PrincipleInstruction

SheetIFU Use

077.1015 Angle piece Ø 6–10 mm Attaches to lid of Reusable Collection System (patient port) to connect tubing at an angle.

077.1016 Angle piece Ø 10–14 mm Attaches to lid of Reusable Collection System (patient port) to connect tubing at an angle.

077.1018 Coupling piece Used to connect tubing to vacuum port of pump.

077.1019 Coupling piece 90 ° Used to connect tubing to vacuum port of pump.

Page 21: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 21

CONNECTORS & TUBINGSArticle Number Description PrincipleInstruction

SheetIFU Use

077.1017 Double conical coupling piece

For connecting 2 tubings to each other.

077.1020 Y-Piece For connecting 3 tubings to each other.

Page 22: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 22

REUSABLE JARSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0110 Suction jar, polysulfone, 1 l For collecting secretions. Can either be attached to carrying handle of portable pump or to optional clampholder.

077.0120 Suction jar, polysulfone, 2 l For collecting secretions. Can either be attached to carrying handle of portable pump or to optional clampholder.

077.0130 Suction jar, polysulfone, 3 l For collecting secretions. Can either be attached to carrying handle of portable pump or to optional clampholder.

077.0150 Suction jar, polysulfone, 5 l For collecting secretions. Can either be attached to carrying handle of portable pump or to optional clampholder.

177.0100

177.0100

177.0100

177.0100

Page 23: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 23

REUSABLE JARSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0125 Suction jar, polysulfone, 0.25 l For collecting secretions. Can either be attached to carrying handle of portable pump or to optional clampholder.

077.0155 Suction jar, polysulfone, 0.5 l For collecting secretions. Can either be attached to carrying handle of portable pump or to optional clampholder.

177.0100

177.0100

Page 24: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 24

2 OR MORE JARSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0095 Serial connection, vacuum Connects vacuum port of one PC jar to the other for serial connection.

077.0160 Serial connection, patient Connects patient port of one liner to serial port of the other for serial connection.

077.0563 Change-over valve with clampholder and tubing set

Integrated in IFUs of disposable liners

077.0542 Reusable serial connector to connect max. four 5 l jars

For automatic filling of a second PSU jar in series.

177.0563

177.0542

Integrated in IFU of disposable liners

Integrated in IFU of disposable liners

For switching vacuum from one jar to the other manually.

Page 25: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 25

SPECIMEN CUPSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0094 Specimen cup for disposable system

For collecting specimens. Can be attached to lid of liner (patient port) of Disposable Collection System.

077.0562 Disposable specimen cup, Ø 6–10 mm

For collecting specimens. Attaches to lid (077.0420) of Reusable Collection System (patient port).

077.0564 Disposable specimen cup, Ø 10–14 mm

For collecting specimens. Attaches to lid (077.0430) of Reusable Collection System (patient port).

200.1034

177.0562

177.0564

Page 26: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 26

ADDITIONAL ACCESSORIESArticle Number Description PrincipleInstruction

SheetIFU Use

077.0523 Wall bracket, single Can be screwed onto the wall to attach Medela accessories, e.g. suction jars.

077.0531 Quiver, 280 mm with holder Can be attached to standard rail of suction pump to store catheters when not in use.

077.0532 Quiver, 480 mm with holder Can be attached to standard rail of suction pump to store catheters when not in use.

177.0523

177.0531

177.0532

Page 27: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 27

REUSABLE LIDSArticle Number Description PrincipleInstruction

SheetIFU Use

077.0440 Small lid with conical patient connection, Ø 6–10 mm and overflow protection device

Attaches to PSU suction jars,0.25 and 0.5 l.

077.0450 Lid for Safety Set with overflow protection device

Attaches to 0.25 l PSU suction jar for direct attachment to Basic, Dominant.

077.0420 Large lid with conical patient connection 6–10 mm and overflow protection device

Attaches to PSU suction jars, 1, 2, 3, 5 l.

077.0430 Large lid with conical patient connection 10–14 mm and overflow protection device

Attaches to PSU suction jars, 1, 2, 3, 5 l.

177.0440

177.0450

177.0420

177.0430

Page 28: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

© Medela UK Ltd. page 28

Territory Account Managers

Julie OldridNorth West/Scotland07854 652 [email protected]

James LeavettNorth West/North Wales/Yorkshire07896 725 [email protected]

Bobby BadeshaMidlands/Mid Wales/Norfolk & Norwich07896 725 [email protected]

James RexworthyLondon & Southern Region07875 681 [email protected]

Tracey TrusselleSouth West/South Wales07951 702 [email protected]

Customer Services

Janette HoltCustomer & Sales Support Healthcare0161 776 0400 [email protected]

Marketing

Stephen RyanMarketing Assistant Healthcare0161 776 0400 [email protected]

Medela UK Downloads Pagewww.medelacustomer.co.uk/downloads

Page 29: Professional Vacuum Systems Accessories Guide Vacuum Systems Accessories Guide. ... the Apgar Test on the ... 077.0731 Foot vacuum regulator 177.0731 Used for regulating vacuum of

Medical Vacuum Technology for Healthcare Professionals

Please contact us or your local Medela representative for details.

Medela AGLättichstrasse 4b6341 Baar, Switzerlandwww.medela.com

UKMedela UK Ltd.Huntsman DriveNorthbank Industrial ParkIrlam, Manchester M44 5EGUKPhone +44 (0)161 776 0400Fax +44 (0)161 776 [email protected]