3
Gaseous Suppression Novec™ 1230

PRODUCTS€¦ · South East Asia Z P]}vo, K8 11 Yishun Industrial Street 1, #03-96 Singapore, 768089 +65 9614 6086 ÁÁÁX. r } }vX }uX P µu µ W=

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRODUCTS€¦ · South East Asia Z P]}vo, K8 11 Yishun Industrial Street 1, #03-96 Singapore, 768089 +65 9614 6086 ÁÁÁX. r } }vX }uX P µu µ W=

Australia

Head OfficeUnit 1, 251 Ferntree Gully RoadMt Waverley VIC 3149 Australia

Brisbane OfficeUnit 7, 93 Rivergate PlaceMurarrie QLD 4172 Australia

Perth Office28 Hargreaves Street,Belmont WA 6104Australia

Sydney OfficeUnit 29/10 Gladstone Road,Castle Hill NSW 2154Australia

1300 742 296Int: +61 3 8542 8900www.fire-protection.com.au ‘Every solution for your special hazard needs’

New Zealand

Auckland OfficeUnit 2, 13 Airborne RoadAlbany North Shore 0632New Zealand

+64 9 415 5488www.fire-protection.net.nz

South East Asia

Regional Head Office11 Yishun Industrial Street 1, #03-96 Singapore, 768089

+65 9614 6086www.fire-protection.com.sg

Kuala Lumpur: +60 19 359 9339

PRODUCTS:

Gaseous Suppression Inert Gas (IG-01, IG-55, IG-100, IG-541) Novec 1230™ Fluid (FK-5-1-12) FM-200® / NAF S 227 (HFC-227ea.) Ecaro 125® / NAF S 125 (HFC-125) Carbon Dioxide (C02) Hybrid Systems (N2 / Water) Pressure Relief Vents Enclosure Integrity Testing Equipment Pipe & Fittings

Water Suppression Water Mist - High Pressure Water Mist - Intermediate Pressure Water Mist - Low Pressure Hybrid Systems (Water / N2) Monitors & Delivery Systems High Speed Deluge

Foam Suppression Foam Concentrates Foam Proportioning Foam Delivery Systems Foam Concentrate Testing

Explosion Protection Explosion Suppression Explosion Isolation Explosion Vents & Pressure Relief Spark Suppression Explosibility Testing

Fire Detection Linear Heat Detection - Digital Linear Heat Detection - Fibre Optic Linear Heat Detection - Micro Chip Flame Detection Video Imaging Detection Spark Detection Control & Indicating Equipment Thermal Imaging Detection

Military & Defence Military Vehicles Naval Vessels

Special Applications Micro Environment Oxygen Reduction Kitchen Protection Systems Dry Chemical Vehicle Systems Compressed Air Foam Marine & Offshore Vapour Mitigation

Support Services Design / Engineering Technical Support Services & Testing

Gaseous Suppression Novec™ 1230

Page 2: PRODUCTS€¦ · South East Asia Z P]}vo, K8 11 Yishun Industrial Street 1, #03-96 Singapore, 768089 +65 9614 6086 ÁÁÁX. r } }vX }uX P µu µ W=

fire-protection.com.au

02 03

OUR COMMITMENT "To provide our customers with the best possible service, the highest quality products and the right solution for your needs"

DESIGN

CYLINDER & VALVE SYSTEMS AVAILABLE IN 360 OR 500 PSI

SEVO Systems set the bar by being the first company to design special hazards fire suppression systems with 3M™ Novec™ 1230 Fire Protection Fluid. Other companies using this environmentally sustainable solution only offer 25 bar (360 psi) pre-engineered and engineered systems. We raised the bar by being the only company to offer 34.5 bar (500 psi) systems. More pressure allows retrofit of existing Halon 1301 systems while utilising welded cylinders.

Our True Retrofit® solution enables you to use existing piping and meet the requirements of industry standards and specifications by simply changing your cylinders and nozzles. The cylinder valve assemblies are equipped with a pressure differential high flow rate valve in order to meet the rapid discharge time of 10 seconds, as specified in AS ISO 14520 and NFPA 2001. Valves are actuated by electric solenoids, pneumatic actuators or manual actuators relieving pressure above the piston. This permits the piston to fully open the valve to allow the agent to discharge through the valve outlet.

EFFICIENT AND FLEXIBLE PIPE NETWORKS

The FORCE500™ features longer pipe lengths between the cylinder and nozzle as well as longer distances between the first and last nozzle. This allows for complex nozzle layouts with smaller pipe sizes and longer pipe runs.

Gaseous Suppression Novec™ 1230

“The SEVO™ 1230 FORCE500™ Clean Agent Fire Suppression System is a revolutionary new technology for clean agent systems that utilises 3M™ Novec™ 1230 Fire Protection Fluid and its unique ability to be pressurised to 500 psi (34.5 bar).”

“EVERY SOLUTION FOR YOUR SPECIAL HAZARD PROBLEMS”

NOVEC™ 1230 FIRE SUPPRESSION SYSTEMS

It allows for longer pipe runs and smaller pipe diameters in addition to its cost saving benefits of using less clean agent in smaller and/or fewer cylinders per project. Along with these new engineering capabilities, it includes standard monitoring components such as an integrated pressure switch, pressure gauge and gauge guard. The low vapor pressure of Novec 1230 Fluid allows for use of low pressure welded cylinders and Schedule 40 piping. With these revolutionary features, the FORCE500™ is a standout to conventional 360 psi (25 bar) systems.

FEATURES

LESS CLEAN AGENT NEEDED

The higher flow rate of the FORCE500™ system allows for enhanced piping limitations. When protecting a main and subfloor hazard with a 360 psi system, a minimum additional 5% agent is required in the subfloor to compensate due to these piping limitations. By utilising the FORCE500™ system, no additional agent is required for the subfloor or subsequent areas.

SMALLER AND/OR FEWER CYLINDERS:REDUCTION IN COSTS

The higher pressure of the FORCE500™ system allows the use of smaller cylinder sizes compared to 360 psi systems. In large, multi-cylinder systems, the FORCE500™ requires fewer cylinders than the equivalent 360 psi systems due to its added pressure.

INSPECTION OF INSTALLATION

Fire Protection Technologies offer field support services conducted by a factory field representative to give verification that the installation of the SEVO 1230 Clean Agent System meets our manufacturers guidelines, AS ISO 14520 and NFPA 2001 requirements and local jurisdiction. The Fire Protection Technologies factory representative trains the contractor on-site, giving the knowledge of verification to meet future code compliance for installations of SEVO 1230 Clean Agent Systems.

These services include:

• Verification of code compliance with AS ISO 14520 and NFPA 2001 (2012 edition)• Pre-construction Project review• Mechanical equipment review & verification• Room Integrity Test - Preliminary/AHJ Requirements• Retrofit Certification – replacement of other clean agent systems

APPLICATIONS

• Medical Equipment/Facilities• Merchant Marine Vessels• Network Centres• Turbine Enclosures

• Electric Utility Facilities• Engine Protection• Manufacturing Facilities

• Off Shore Oil Rigs• Paint Rooms

• Pump Stations• Mass Transit Vehicles

• Clean Rooms• Combat Vehicles• Computer Rooms• Data Storage Facilities• Libraries, Museums & Archives

• Automobiles• Cable Spreading Rooms• Cellular Sites• Generators

Page 3: PRODUCTS€¦ · South East Asia Z P]}vo, K8 11 Yishun Industrial Street 1, #03-96 Singapore, 768089 +65 9614 6086 ÁÁÁX. r } }vX }uX P µu µ W=

Australia

Head OfficeUnit 1, 251 Ferntree Gully RoadMt Waverley VIC 3149 Australia

Brisbane OfficeUnit 7, 93 Rivergate PlaceMurarrie QLD 4172 Australia

Perth Office28 Hargreaves Street,Belmont WA 6104Australia

Sydney OfficeUnit 29/10 Gladstone Road,Castle Hill NSW 2154Australia

1300 742 296Int: +61 3 8542 8900www.fire-protection.com.au ‘Every solution for your special hazard needs’

New Zealand

Auckland OfficeUnit 2, 13 Airborne RoadAlbany North Shore 0632New Zealand

+64 9 415 5488www.fire-protection.net.nz

South East Asia

Regional Head Office11 Yishun Industrial Street 1, #03-96 Singapore, 768089

+65 9614 6086www.fire-protection.com.sg

Kuala Lumpur: +60 19 359 9339

PRODUCTS:

Gaseous Suppression Inert Gas (IG-01, IG-55, IG-100, IG-541) Novec 1230™ Fluid (FK-5-1-12) FM-200® / NAF S 227 (HFC-227ea.) Ecaro 125® / NAF S 125 (HFC-125) Carbon Dioxide (C02) Hybrid Systems (N2 / Water) Pressure Relief Vents Enclosure Integrity Testing Equipment Pipe & Fittings

Water Suppression Water Mist - High Pressure Water Mist - Intermediate Pressure Water Mist - Low Pressure Hybrid Systems (Water / N2) Monitors & Delivery Systems High Speed Deluge

Foam Suppression Foam Concentrates Foam Proportioning Foam Delivery Systems Foam Concentrate Testing

Explosion Protection Explosion Suppression Explosion Isolation Explosion Vents & Pressure Relief Spark Suppression Explosibility Testing

Fire Detection Linear Heat Detection - Digital Linear Heat Detection - Fibre Optic Linear Heat Detection - Micro Chip Flame Detection Video Imaging Detection Spark Detection Control & Indicating Equipment Thermal Imaging Detection

Military & Defence Military Vehicles Naval Vessels

Special Applications Micro Environment Oxygen Reduction Kitchen Protection Systems Dry Chemical Vehicle Systems Compressed Air Foam Marine & Offshore Vapour Mitigation

Support Services Design / Engineering Technical Support Services & Testing