17
PRODUCT NEWS Product Discontinuation Issue Date March 1, 2018 Digital Fiber Sensor No. OMSQ-C (03)178127- EU Discontinuation Notice of Digital Fiber Amplifier Unit E3X- DA-N Series. Product Discontinuation Recommended Replacement Digital Fiber Amplifier Unit Smart Fiber Amplifier Unit E3X-DAH□ E3X-DA□1-N 2M E3X-DAB□ E3X-DAG□ E3X-DA□V E3X-DAT6-2 E3X-DA7/9 E3NX-FAH□ Series E3NX-FA□1-AN 2M Color Mark Fiber Amplifier E3NX-CA□ Series E3NX-CA□ Series No recommended replacement No recommended replacement No recommended replacement Final order entry date The end of March 2019 Date of The Last Shipping The end of June 2019 Caution on recommended replacement When going to use E3NX-FA Series. Please pay attention to the following. 1) The dimensions of sensor are different. Please refer to the dimensions for details. 2) The operation methods are different. Please refer to operation methods for details. 3) The characteristics are different. Please refer to characteristics and operation ratings for details. 4) Notice that the position of output indicator is different. 5) Control-output are different. Please refer to characteristics and operation ratings for details. OMRON Corporation Industrial Automation Company No. OMSQ-C (03)178127- EU

Product · Web viewLoad power supply voltage: 30 VDC max., open-collector outputLoad current: Groups of 1 to 3 Amplifiers: 100 mA max.,Groups of 4 to 30 Amplifiers: 20 mA max.Residual

Embed Size (px)

Citation preview

PRODUCTNEWS Product Discontinuation

Notices Issue DateMarch 1, 2018

Digital Fiber Sensor No. OMSQ-C (03)178127-EU

Discontinuation Notice of Digital Fiber Amplifier Unit E3X-DA-N Series.

Product Discontinuation Recommended ReplacementDigital Fiber Amplifier Unit Smart Fiber Amplifier Unit

E3X-DAH□E3X-DA□1-N 2M

E3X-DAB□E3X-DAG□E3X-DA□VE3X-DAT6-2E3X-DA7/9

E3NX-FAH□ SeriesE3NX-FA□1-AN 2M

Color Mark Fiber AmplifierE3NX-CA□ SeriesE3NX-CA□ Series

No recommended replacement

No recommended replacement

No recommended replacement

Final order entry dateThe end of March 2019

Date of The Last ShippingThe end of June 2019

Caution on recommended replacementWhen going to use E3NX-FA Series. Please pay attention to the following.1) The dimensions of sensor are different. Please refer to the dimensions for details.2) The operation methods are different. Please refer to operation methods for details.3) The characteristics are different. Please refer to characteristics and operation ratings for details.4) Notice that the position of output indicator is different.5) Control-output are different. Please refer to characteristics and operation ratings for details.6) Optical communication to E3NX-FA/CA series is not available. Notice that channel recognition and Mutual interference prevention is not available at communication status.7) Mobile console E3X-MC11 is not available.8) The Communication Unit E3X-DRT21、E3X-SRT21 and E3X-CIF11 cannot be connected.9)When using Fiber head E32-D61/D73/D81R/T61/T81R(D81R/T61/T81R are discontinued)series,

notice that the pitch between deliver and receiver hole is different compared with E3X-HD series, and installation is unavailable. Please also change the Fiber head to the following types.

E32-D61-S/D73-S/D81R-S/T61-S/T81R-S series.

When going to use E3NX-CA Series. Please pay attention to the following。1)E3X-DAB(blue)、E3X-DAG(green) can distinguish power with contrast mode.2) When using to distinguish several objects. Please to check whether each object can be distinguished.*Because of the difference of RGB turning, when there are several kinds of color, maybe it will be unable to distinguish.

OMRON Corporation Industrial Automation Company No. OMSQ-C (03)178127-EU

Difference from discontinued productRecommended

replacement ModelBody Color

Dimen-sions

Wire connection

Mounting Dimensions

Charac-teristics

Operation ratings

Operation methods

E3NX-FA Series * * ** ** * * *E3NX-CA Series * * ** ** * * *

** : Compatible* : The change is a little/Almost compatible-- : Not compatible- : No corresponding specification

Product Discontinuation and recommended replacementProduct discontinuation Recommended replacement

E3X-DAB11-N 2M E3NX-CA11 2ME3X-DAB6 E3NX-CA6E3X-DAB41-N 2M E3NX-CA41 2ME3X-DAB8 E3NX-CA8E3X-DAG6 E3NX-CA6E3X-DAG11-N 2M E3NX-CA11 2ME3X-DAG41-N 2M E3NX-CA41 2ME3X-DAG8 E3NX-CA8E3X-DAH11-N 2M E3NX-FAH11 2ME3X-DAH6 E3NX-FAH6E3X-DAH41-N 2M E3NX-FAH41 2ME3X-DAH8 E3NX-FAH8E3X-DA21-N 2M E3NX-FA11-AN 2ME3X-DA51-N 2M E3NX-FA41-AN 2ME3X-DA41V 2M No recommended replacementE3X-DAT6-2 No recommended replacementE3X-DA14V No recommended replacementE3X-DA44V No recommended replacementE3X-DA11V 2M No recommended replacementE3X-DA7 No recommended replacementE3X-DA9 No recommended replacement

2

Body colorProduct discontinuationModel E3X-DA-N Series

Recommendable replacementModel E3NX-CA SeriesModel E3NX-FA Series

Body(code type)E3X-DA-N Series

body:blackCover printing :orangeCase side:No printing

E3NX-FA Series /E3NX-CA Series

body:blackCover printing:silverCase side:black name plate with white printing

Operation panel

7-seg display:redOperation button:orangeOperation panel printing:orange

7-seg display:green+whiteOperation button:blackOperation panel printing:white

Cable

Cable:dark grey Cable:black

Dimensions

3

Product discontinuationModel E3X-DA-N Series

Recommendable replacementModel E3NX-CA SeriesModel E3NX-FA Series

Pre-wired Amplifiers

Amplifiers with Standard ConnectorsTwin-output Models

CharacteristicsMark-detecting models E3X-DAB□-N/E3X-DAG□-N

4

Product discontinuationModel E3X-DAB□-NModel E3X-DAG□-N

Recommendable replacementModel E3NX-CA□Series

5

Light source(wavelength)E3X-DAB□-N :Blue Led(470nm)

E3X-DAG□-N :Green Led(525nm)White LED (420 to 700 nm)

Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.

10 to 30 VDC, including 10% ripple (p-p)

Power consumption(at power

supply voltage of 24VDC)

Normally mode 960mW max. 960mW max.Eco mode 720mW max 720mW max

Eco Lo mode - 800mW max.

Digital display not lit: 600mW max. -

Control output

Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,Open collector (NPN or PNP

output, depending on the model)Light ON/Dark ON selectable

Load power supply voltage: 30 VDC max., open-collector output

Load current: Groups of 1 to 3 Amplifiers: 100 mA max.,

Groups of 4 to 30 Amplifiers: 20 mA max.

Residual voltage: At load current of less than 10 mA: 1 V max.

At load current of 10 to 100 mA: 2 V max.

OFF current: 0.1 mA max.

Protection circuits

Power supply reverse polarity

protectionProvided Provided

Output short-circuit protection Provided Provided

Out reverse polarity protection Not provided Provided

Response time

Super-high-speed mode 0.25ms 50μs(Contrast Mode only)

High-speed Mode - 250μsStandard mode 1ms 1ms

Giga-power Mode - 16msSuper-long-distan

ce mode4ms -

Sensitivitysetting Teaching or manual method

Smart Tuning (2-point tuning,full auto tuning,

or 1-point tuning (1% to 99%)) or manual adjustment

Functions

Timer

OFF-delay timer: 0 to 200ms, 1 to 20ms (set in 1-ms units); 20 to

200ms (set in 5-ms units)Using Mobile Console: OFF delay, ON delay, or one shot (selectable)

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay +

OFF-delay timer (Countedby 0.1 s in a range of 0.1 to 0.5ms, by 0.5ms for 0.5 to 5ms, and by 1ms for 5

to 9999ms. Default: 10ms, Error: 0.1ms)

Zero-reset Negative values can be displayed.Contrast Mode only

Negative values can be displayed. (Threshold level is shifted.)

Initial-reset Settings can be returned to defaults as required. -

Operation mode -

Contrast Mode: NO (Light-ON) or NC (Dark-ON)

Color Mode: NO (ON for match: ON for same color as registered color) or

NC (ON for mismatch: ON fordifferent color from registered color)

Resetting settings -Select from initial reset (factory

defaults), user reset (saved settings), or bank reset.

eco mode - Select from OFF (digital display lit),

6

Eco ON (digital display not lit) Eco LO (digital display dimmed).

Bank switching - Select from banks 1 to 8.

power tuning level -

Set from 100 to 9,999. (The RGB maximum incident level at Smart

Tuning is adjusted to the power tuninglevel.)

changing the display -

Threshold level and incident level,Channel number and incident level,

RGB display and incident level,Bank display and incident level

No.of Units for mutual

interference prevention

10 UnitsHigh-speed Mode (HS):10 UnitsStandard Mode (Stnd):10 Units

Giga-power Mode (GIGA):10 Units

Indicators

Operation indicator (orange), 7-segment digital incident level

display (red), 7-segment digital incident level percentage

display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-segment digital

thresholddisplay (red)

7-segment displays (Sub digital display: green, Main digital display:

white)Display direction: Switchable between normal and reversed. OUT indicator (orange), NO/NC indicator (orange), Smart Tuning indicator (blue), and

OUT selection indicator (orange, only on models with 2 outputs)

Display timing Switching between normal/peak-hold/bottom-hold possible -

Display orientation Switching between normal/reverse possible -

Optical axis adjustment Optical axis adjustment possible (hyper-flashing function) -

Ambient Illumination

(receiver side)

Incandescent lamp 10,000 lx max. 20,000 lx max

Sunlight 20,000 lx max 30,000 lx max

Ambienttemperature

Operating

Groups of 1 to 3 Amplifiers: −25 to 55°C

Groups of 4 to 11 Amplifiers:−25 to 50°C

Groups of 12 to 16 Amplifiers: −25 to 45°C

Groups of 1 or 2 Amplifier Units:−25 to 55°C,

Groups of 3 to 10 Amplifier Units:−25 to 50°C,

Groups of 11 to 16 Amplifier Units:−25 to 45°C,

Groups of 17 to 30 Amplifier Units: −25 to 40°C

Storage −30 to 70°C (with no icing or condensation)

−30 to 70°C (with no icing or condensation)

Weight(Packed

state)

Pre-wired(standard

cable length:2 m)100 g E3NX-CA11/E3NX-CA41:115g

Standard connector

55 g E3NX-CA6/E3NX-CA8:60g

MaterialCase Polybutylene terephthalate (PBT) Polycarbonate (PC)Cover Polycarbonate Polycarbonate

Cable covering - Polyvinyl chloride (PVC)Accessories Instruction sheet Instruction sheet

Infrared models E3X-DAH□Product discontinuation

Model E3X-DAH□Recommendable replacement

Model E3NX-FAH□Series

Light source(wavelength) Infrared LED(870 nm) Infrared LED (870nm)

Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.

10 to 30 VDC, including 10% ripple (p-p)

Power Normally mode 960mW max 1080mW max

7

consumption(at power

supply voltage of 24VDC)

Eco mode 720mW max. 920mW maxEco Lo mode - 1020mW max

Digital display not lit: 600mW max. -

Control output

Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,Open collector (NPN or PNP

output, depending on the model)Light ON/Dark ON selectable

Load power supply voltage: 30 VDC max., open-collector output (depends

on the NPN/PNP output format)Load current: Groups of 1 to 3

Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max.

Protection

circuits

Power supply reverse polarity protection Provided Provided

Output short-circuit protection Provided Provided

Out reverse polarity protection Not provided Provided

Response time

Super-high-speed mode 0.25ms 30μsHigh-speed Mode - 250μsStandard mode 1ms 1ms

Giga-power Mode - 16msSuper-long-distance mo

de4ms -

Sensitivitysetting Teaching or manual method

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or

percentage tuning (-99% to 99%)) or manual adjustment

Functions

Timer

OFF-delay timer: 0 to 200ms, 1 to 20ms (set in 1-ms units); 20

to 200ms (set in 5-ms units)Using Mobile Console: OFF delay, ON delay, or one shot

(selectable)

Select from timer disabled OFF-delay, ON-delay, one-shot, ON-delay + OFF-delay timer: 1 to

9,999ms

Automatic power control(APC) - Always enabled.

Zero-reset Negative values can be displayed.

Negative values can be displayed. (Threshold value is shifted.)

Initial-reset Settings can be returned to defaults as required. -

Resetting settings -Select from initial reset (factory defaults) or user reset (saved

settings).

eco mode -Select from OFF (digital display lit)

Eco ON (digital display not lit)Eco LO (digital display dimmed).

Bank switching - Select from banks 1 to 4.power tuning level - Select from ON or OFF.

Output 1 -Select from normal

detection mode or areadetection mode.

No.of Units for mutual interference prevention 10 Units

Super-high-speed mode(SHS):0 UnitsHigh-speed Mode (HS):10 UnitsStandard Mode (Stnd):10 UnitsGiga-power Mode (GIGA):10 Units

Indicators Operation indicator (orange), 7-segment digital incident level

display (red), 7-segment digital incident level percentage

display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-

7-segment displays (Sub digital display: green, Main digital display:

white)Display direction: Switchable between

normal and reversed.OUT indicator (orange), L/D indicator

(orange), ST indicator (blue), DPC

8

segment digital thresholddisplay (red)

indicator (green),and OUT selection indicator (orange,

only on models with 2 outputs)

Display timing Switching between normal/peak-hold/bottom-hold possible -

Display orientation Switching between normal/reverse possible -

Optical axis adjustment Optical axis adjustment possible (hyper-flashing function) -

Ambient Illuminatio

n(receiver

side)

Incandescent lamp 10,000 lx max. 20,000 lx max

Sunlight 20,000 lx max. 30,000 lx max

Ambienttemperatu

re

Operating

Groups of 1 to 3 Amplifiers: −25 to 55°C

Groups of 4 to 11 Amplifiers:−25 to 50°C

Groups of 12 to 16 Amplifiers: −25 to 45°C

Groups of 1 or 2 Amplifier Units:−25 to 55°C,

Groups of 3 to 10 Amplifier Units: −25 to 50°C,

Groups of 11 to 16 Amplifier Units: −25 to 45°C,

Groups of 17 to 30 Amplifier Units: −25 to 40°C

Storage −30 to 70°C(with no icing or condensation)

−30 to 70°C(with no icing or condensation)

Weight(Packed

state)

Pre-wired(standard cable length:2 m) 100 g E3NX-FAH11/E3NX-FAH41:115g

Standard connector 55 g E3NX-FAH6/E3NX-FAH8:60g

MaterialCase Polybutylene terephthalate

(PBT) Polycarbonate (PC)

Cover Polycarbonate Polycarbonate (PC)Cable covering - PVC

Accessories Instruction sheet Instruction Manual

Standard models\ Monitor-output models E3X-DA□1-NProduct discontinuation

Model E3X-DA□1-NRecommendable replacement

Model E3NX-FA□1ANLight source(wavelength) Red LED (660 nm) Red, 4-element LED (625 nm)

Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.

10 to 30 VDC, including 10% ripple (p-p)

Power consumptio

n(at power

supply voltage of

Normally mode 960mW max 960mW max.Eco mode 720mW max. 770mW max

Eco Lo mode - 870mW max.Digital display not lit: 600mW max. -

9

24VDC)

Control output

ON/OFFoutput

Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,Open collector (NPN or PNP

output, depending on the model)Light ON/Dark ON selectable

Load power supply voltage:30 VDC max., open-collector output(depends on the NPN/PNP output

format)Load current: Groups of 1 to 3

AmplifierUnits: 100 mA max., Groups of 4 to

30Amplifier Units:

20 mA max.Residual voltage:        

At load current of less than 10 mA: 1 V max.

At load current of 10 to 100 mA: 2 V max.

OFF current: 0.1 mA max.

Monitoroutput

Standard models:Not providedMonitor output models:

Load 1 to5 VDC,10 kΩ min.

-

Protection circuits

Power supply reverse polarity

protectionProvided Provided

Output short-circuit protection Provided Provided

Out reverse polarity protection Not provided Provided

Response time

Super-high-speed mode 0.25ms 80 μs

High-speed Mode - 250μsStandard mode 1ms 1ms

Giga-power Mode - 16msSuper-long-distance

mode4ms -

Sensitivitysetting Teaching or manual method

Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning,

percentage tuning (−99% to 99%)) or manual adjustment

Functions

Timer

OFF-delay timer: 0 to 200ms, 1 to 20ms (set in 1-ms units); 20 to

200ms (set in 5-ms units)Using Mobile Console: OFF delay, ON delay, or one shot (selectable)

Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-

delay + OFF-delay timer: 1 to 9,999ms

Automatic power control(APC)

Fiber-optic current digitalcontrol Always enabled.

Zero-reset Negative values can be displayed. Negative values can be displayed. (Threshold value is shifted.)

Initial-reset Settings can be returned to defaults as required. -

Monitor focus

Standard models:Not providedMonitor output models:

Upper and lower limits can be set as required for every 100 digital

values

-

Resetting settings - Select from initial reset (factory defaults) or user reset (saved

10

settings).

eco mode -Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).

Bank switching - Select from banks 1 to 4.power tuning level - Select from ON or OFF.

No. of Units for mutual interference

prevention10 Units

Super-high-speed mode(SHS):0 UnitsHigh-speed Mode (HS):10 UnitsStandard Mode (Stnd):10 Units

Giga-power Mode (GIGA):10 Units

Output 1 - Select from normal detection mode or area detection mode.

Output 2 - Select from Analog scalingor Analog offset.

Hysteresis width- Select from standard setting or user

setting. For a user setting, the hysteresis width can be set from 0 to

9,999.

Indicators

Operation indicator (orange), 7-segment digital incident level

display (red), 7-segment digital incident level percentage

display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-

segment digital thresholddisplay (red)

7-segment displays (Sub digital display: green, Main digital display:

white)Display direction: Switchable between

normal and reversed.OUT indicator (orange), L/D indicator

(orange), ST indicator (blue), DPC indicator (green),

and OUT selection indicator (orange, only on models with 2 outputs)

Ambient Illumination

(receiver side)

Incandescent lamp 10,000 lx max. 20,000 lx max.,

Sunlight 20,000 lx max. 30,000 lx max.

Ambienttemperature

Operating

Groups of 1 to 3 Amplifiers: −25 to 55°C

Groups of 4 to 11 Amplifiers:−25 to 50°C

Groups of 12 to 16 Amplifiers:−25 to 45°C

Groups of 1 or 2 Amplifier Units:−25 to 55°C,

Groups of 3 to 10 Amplifier Units: −25 to 50°C,

Groups of 11 to 16 Amplifier Units: −25 to 45°C,

Groups of 17 to 30 Amplifier Units: −25 to 40°C

Storage .−30 to 70°C (with no icing or condensation)

.−30 to 70°C (with no icing or condensation)

Ambient humidityOperating and storage: 35% to

85% (with no condensation)

Operating and storage: 35 to 85% (with no condensation) within the

surrounding air temperature range shown above

Insulation resistance 20 MΩ min. (at 500 VDC) 20 MΩ min. (at 500 VDC)Dielectric strength 1,000 VAC at 50/60 Hz for 1 min 1,000 VAC at 50/60 Hz for 1 min

Vibration resistance(destruction)

10 to 55 Hz with a 1.5-mm double amplitude for 2 h each in X, Y and

Z directions

10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y,

and Z directions

Shock resistance(destruction)

500m/s2, for 3 times each in X, Y and Z directions

500 m/s2 for 3 times each in X, Y, and Z

directions

degree of protection IEC IP50 (with Protective Cover attached)

-

Weight(Packed

state)

Pre-wired(standard cable length:2 m) Approx. 100 g Approx. 115 g

MaterialCase Polybutylene terephthalate (PBT) Polycarbonate (PC)Cover Polycarbonate Polycarbonate (PC)

11

Cable covering - PVCAccessories Instruction sheet Instruction Manual

Operation ratingsProduct discontinuationModel E3X-DA-N Series

Recommendable replacementModel E3NX-FA SeriesModel E3NX-CA Series

Sensing distance Sensing distance

Operation methods

12

Product discontinuationModel E3X-DA-N Series

Recommendable replacementModel E3NX-CA SeriesModel E3NX-FA Series

E3NX-CA Series

E3NX-FA Series

Specifications and prices in this product news are as of the issue date and are subject to change without notice.Only main changes in specifications are described in this document. Please be sure to read the relevant catalogs, datasheets, product specifications, instructions, and manuals for precautions and necessary information when using products.

13