24
7/31/2019 Product Summary Guide 352 http://slidepdf.com/reader/full/product-summary-guide-352 1/24

Product Summary Guide 352

Embed Size (px)

Citation preview

Page 1: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 1/24

Page 2: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 2/24

Acromag: The I/O LeaderAcromag is a customer-driven manufac-

turer focused on developing embedded

I/O products that provide the best long

term value in the industry. Compare

and you’ll find that Acromag products

offer an unmatched balance of price,

performance, and features.

50+ Years of I/O Experience

Acromag has more than 50 years of

measurement and control experience.

Since 1957, we have delivered nearly a

million units to thousands of customers

around the globe for manufacturing,

power, environmental, transportation,

and military applications.

Top Quality and a 7-Year Warranty

We take every measure to guarantee youdependable operation and products that

perform at or beyond their specifications.

Our state-of-the-art manufacturing and

military-grade components add an extra

degree of ruggedness. Most products

qualify for an extended 7-year warranty.

And with ISO9000/AS9100 certified

quality control, you get full confidence.

 All trademarks are the property of their respective owners.

Online Ordering

For your convenience, Acromag provides

full product documentation and pricing

information on our website. You can

obtain quotes or even place your order

directly on our website.

Fast Delivery from Stock

Most products can be shipped within

24 hours of receiving your order.

Special Services

We are happy to accommodate your

special requirements and offer the

following services:

• Custom product development

• Custom calibration

• Source inspections, quality audits

• Special shipping, documentation

• Protective humiseal coating

• Plastic and stainless steel tagging

Certification and Approvals

Many Acromag products carry globally

recognized agency approvals and safety

certifications.

• CE • Ethernet conformance

• UL, cUL • Modbus conformance

• Atex • Profibus certification

• CSA

2

Experience counts:

especially when

 selecting an I/O

 partner. And with

50 years of I/O

experience, Acromag

can help you improve

reliability, increase

 productivity and 

reduce your costs.

Call 877-214-6267 or 248-295-0880 for technical assistance.

DEPENDABLE SOLUTIONS

Page 3: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 3/24

3Visit www.acromag.com or e-mail us at [email protected]

Ethernet I/OAcromag’s EtherStax® andBusWorks® 900EN series cangreatly reduce your remoteI/O costs. Whether you havea large quantity of I/O or justa a few signals to interface,we have a cost-effective andspace-saving solution for you.All of Acromag’s I/O mod-ules are ruggedly designedfor dependable operation inrough industrial environments

Modbus I/OAnother BusWorks® product,the 900MB series provides asimple and affordable solutionfor remote I/O. These inch-wide analog and discrete I/Omodules monitor or control asmany as twelve channels.

Profibus I/OThe BusWorks® 900PB seriescan greatly reduce the cost to

monitor or control distributedI/O. Select from a variety ofanalog and discrete I/O mod-ules. Independent modulesare ideal for sites with just afew points or limited space.

Panel MetersThese bright displays caninterface current, voltage, ortemperature input signals,across Modbus-RTU networksor provide 4-20mA output.

I/O AccessoriesLook to Acromag for manyother I/O solutions such asfront-end signal conditionersand network communicationdevices.

Isolators andSignal Splitters

Acromag has the industry’sbest selection of isolators toeliminate ground loops andprotect your equipment fromsurges. From multi-channelloop-powered isolators toAC-powered signal splitters,we have the right solution foryour application.

Transmitters andSignal ConvertersSelect from dozens of modelsincluding intelligent program-mable signal conditioners,multi-channel isolated signalconverters, and two-wiretransmitters. Numerous input,output, and power options areavailable. Flexible mountingsupports DIN-rail and field-mount formats.

Limit AlarmsFrom simple limit relay tripsto programmable alarms,Acromag has your solution.Configure alarms for on/offcontrol, limits, window/band-pass, deviation, peak/valley,or rate of change detection.Alarms are available for AC,DC, and loop-poweredapplications.

ComputationThese I/O modules computeyour custom math equationsto perform functions such assignal characterizing, adding,multiplying, integrating, andtotalizing. Spreadsheet-styleequation entry makes it easy.Select current, voltage, pulse,or frequency output.

DISTRIBUTED I/O SIGNAL CONDITIONERS

www.acromag.com/profibus

www.acromag.com/isolators

www.acromag.com/transmitters

www.acromag.com/computation

www.acromag.com/alarms

www.acromag.com/ethernet 

www.acromag.com/panelmeters

www.acromag.com/modbus

4

10

12

22

14

16

18

20

www.acromag.com/accessories

22

Page 4: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 4/24

Rugged and reliable

Ethernet I/O modules

are ready for your 

most challenging

monitoring & control 

applications.

EtherStax I/O Blocks

EtherStax I/O blocks provide a rugged,

high-density solution to interface many

analog or discrete signals to your control

system. Modbus TCP/UDP/IP support

enables reliable host data transfer or

peer-to-peer communication. Web-based

configuration simplifies setup with any

web browser. For OEM systems requiring

special mounting, enclosureless versions

are available. EtherStax are ideal for a

broad range of monitoring and control

or SCADA applications.

Rugged, Industrial-Grade Design

EtherStax are designed for high-reliability

operation in hostile environments. Units

are shock/vibration-resistant and feature

3-way isolation with surge protection.

I/O circuitry has over-temperature, over-

voltage, and over-current protection.

Redundant Power & Communication

Self-healing, redundant communication

paths support dual copper or fiber-optic

media. Dual DC power connections

for battery backup ensure dependable

operation. If host communication is lost,

outputs fail safely and a relay provides

local alarming or shutdown functions.

Stackable, High-Density I/O

Get up to 96 channels on a single unit

to monitor sensors, control devices, or

add local alarms. Aluminum enclosures

interlock for secure stacking that saves

space mounting on a surface or rail.

i2o peer-to-peer communication

Input channels on one unit can write

directly to outputs on another unit

without a host controller in between.(See Page 8 for more information)

Inputs• Analog current/voltage• 8B signal conditioning modules• Discrete level (on/off, open/close, hi/lo)

Outputs• Discrete switches and relays

Power• 18-36V DC

Communication• Modbus TCP/UDP/IP, i2o peer-to-peer

Software Support• Modbus C library (see Page 23)

Approvals• CE, UL/cUL Class I Div 2• Modbus TCP/IP conformance

For more information, visit our website at www.acromag.com/EtherStax 

4 Call 877-214-6267 or 248-295-0880 for technical assistance.

ETHERNET I/O: HIGH-DENSITY

Page 5: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 5/24

5

High DensityDiscrete I/O

Up to 96 channels/unitfor cost/space-efficiencyES211x models provide aneasy way to interface a very

large quantity of I/O to yourcontrol system. Some modelssupport high-voltage signalswith isolation between allcircuits for extra reliability.

Highlights• Up to 96 discrete I/O

(any input/output mix)

• Ch-to-ch isolation adds pro-tection and noise immunity

• Fast updates refresh data on

all 96 channels in 1mS• Peer-to-peer i2o messaging

sends fast updates in <5mS

• Change of state detectioncatches quick changes

• Loop-back monitoringconfirms output state

High DensityAnalog I/O

Up to 64 inputs or16 outputs per unitES215x, ES216x, and ES217xmodels can interface a lot of

inputs and/or outputs to yournetwork. Differential inputseliminate ground loops. Built-in loopback circuits help verifythe output values.

Highlights

• Up to 64 SE (32 differential)DC voltage or current inputs

• 16-bit A/D and D/A ensuresprecision and accuracy

• Scans all inputs in <10mS;

scans 4-ch group in 770µS

• Updates outputs in <1mS/ch

• DB25 easily connects a rackof isolated 8B I/O modules

• Integrator/totalizer functionhas non-volatile memory

Open boardOEM versions

Flexible mounting andredundant ring supportAll EtherStax models can beordered without the aluminum

enclosure. The exposed circuitboard versions deliver thesame level of I/O performanceand reliability, but facilitatespecial mounting needs. Theyare more compact for tighterstacking and even more cost-effective for price-sensitivehigh-volume applications.

Highlights• Lighter and more compact

for OEM installations or

mounting in tight quarters• Higher-density stacking for

use with NEMA enclosures

• Supports a variety of specialmounting hardware

• -40 to 75°C operating range

Industrial-gradeEthernet switch

Managed / unmanaged,redundancy or notAcromag’s five and eight-portEthernet switches are specially

designed for industrial use.Rugged construction andmany security features ensurereliable operation. Self-healingredundant ring technologyprevents network interruptionsfor secure communications.

Highlights• Managed and unmanaged

models for copper or fiber

• Redundant ring technology(<300mS recovery)

• -25 to 70°C operation

• 1200V port-to-port isolationand surge suppression

• CE, UL/cUL Class I, Div 2

Please refer to Page 9 for additional information.

Visit www.acromag.com or e-mail us at [email protected]

EtherStax Discrete I/O Blocks

Model Digital Input Digital Output Input Range Output Range Isolation Communication Protocol

ES2113 96 bi-directional input/output channe ls (any mix ) 0-28V DC 0-28V DC (0.45A/ch) I/O i sola ted as a group Modbus TCP/IP, UDP/IP, i2o

ES2117 32 input channels 16 output channe ls 20-36V DC 2A @ 250V AC or 110V DC channel-to-channe l i sola tion Modbus TCP/IP, UDP/IP, i2o

ETHERSTAX ES2100 SERIES

EtherStax Analog I/O Blocks

Model Analog Input Analog Output Input Range Output Range Isolation Communication Protocol

ES2151/52 32 single-ended channels 16 channels 16 current + 16 voltage* DC DC current or voltage* I/O isolated as a group Modbus TCP/IP, UDP/IP, i2o

ES2153 32 single-ended channels 16 current + 16 voltage* DC I/O isolated as a group Modbus TCP/IP, UDP/IP, i2o

ES2161/62 32 differential channels DC current or voltage* I/O isolated as a group Modbus TCP/IP, UDP/IP

ES2163/64 64 single-ended channels DC current or voltage I/O isolated as a group Modbus TCP/IP, UDP/IP

ES2171/72 16 channels DC current or voltage* I/O isolated as a group Modbus TCP/IP, UDP/IP, i2o

* A DB25 serial port connects alternate voltage inputs or outputs from/to a rack of 8B analog I/O modules (see Page 22).

Page 6: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 6/24

These independent,

compact I/O modules

are ideal when you

need to interface a

 small quantity of 

I/O channels to your 

 system quickly, easily,

and economically.

BusWorks I/O Modules forEtherNet/IP, Modbus TCP/IP

Acromag’s BusWorks 900EN I/O modules

are the best way to monitor or control

a few I/O devices without all the hassles

and expensive startup costs you get with

complex block I/O systems.

Each inch-wide module has its own

EtherNet/IP or Modbus TCP/IP network

port and up to 16 I/O channels. No

buscouplers, CPUs, I/O racks, or special

power supplies are required. Just connect

your sensors, valves, motors, or other

devices and the I/O modules will link the

data to your control network. If you need

any extra channels in the future, just add

another I/O module.

Setup is fast and easy, too. A web

browser is the only software you need.

An embedded web page provides a

simple configuration menu to help you

quickly set desired operating parameters

and functions.

Commercial or Industrial-Grade I/O

Ask about commercial-grade models to

save money on less demanding projects.

Peer-to-peer communication with i2o

Input modules can write directly to

remote output modules without a PLC or

a PC in between.

Acromag also offers isolated, industrial-

grade 5-port switches to simplify your

network connections.

Inputs• Thermocouple • DC current/voltage• RTD/resistance • AC current• Millivolt • Discrete level/status• 8B signal conditioning modules

Outputs• DC voltage • Discrete switches• DC current

Power• 15-36V DC

Software Support• Configuration via web browser• Modbus C library (See Page 23)• Ethernet/IP .eds files• Utilities

Approvals• CE, ATEX, UL/cUL Class I Div 2• EtherNet/IP, Modbus TCP/IP conformance

For more information, visit our website at www.acromag.com/BusWorks-900EN 

6 Call 877-214-6267 or 248-295-0880 for technical assistance.

ETHERNET I/O: COMPACT SIZE

958ENwith 8Bs

Page 7: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 7/24

Analog I/OModules

Multi-channel unitssave space, reduce costs96xEN/97xEN models networkanalog input or output signals.

Low noise, 16-bit A/D and12-bit D/A converters deliverhigh accuracy. Input modelsaccept voltage, current andtemperature sensor signals.Output units control devicesor write to other instruments.

Highlights• Universal I/O ranges

• Differential inputs eliminateground loops

Discrete I/OModules

Monitors and/or controlsup to 16 devices per unit98xEN models provide anisolated interface for discrete

I/O signals. Outputs provideon/off, high/low, or open/closedevice control. Inputs sensethe level/status of motors,valves and other equipment.

Highlights• Bi-directional I/O controls

and verifies level in one unit.

• Selectable failsafe modes

• Pulse counting capabilitywith non-volatile memory

Combination I/OModules

Mix analog and discreteI/O on a single module95xEN modules combine thefunctionality of three separate

models on one unit. Interfacesensors or process signals tothe network; drive devices orinstruments; and monitor orcontrol discrete devices.

Highlights• Universal I/O ranges

• 16-bit A/D & D/A convertersfor precise measurements

• Bi-directional discrete I/O foreasy loopback monitoring

Industrial-GradeEthernet Switch

Rugged 5-port switch900EN switches have internalintelligence for fast and easynetwork installation with auto

data rate, flow control, andcross-over. No setup needed ifused as a simple switch withAcromag I/O modules.

Highlights• -25 to 70°C range

• 1500V port-to-port isolation

• Redundant power support

• CE, ATEX, UL/cUL Class I,Div 2 approvals

7Visit www.acromag.com or e-mail us at [email protected]

Combination I/O Modules

Model Analog Input Analog Output Discrete I/O Communication Protocol Special Functions

951EN, 952EN 4 channels 2 channels 6 bi-directional channels, 0-35V DC Ethernet/IP or Modbus TCP/IP, i2o output loopback

958EN 16 channels (8Bs to DB25) 16 inputs (SSRs to DB25), 0-5V DC Modbus TCP/IP integrator/totalizer, sample avg.

BUSWORKS 900EN SERIES

Discrete I/O ModulesModel Discrete Input Discrete Output I/O Type Communication Protocol Special Functions

981EN 12 channels 0-35V DC, active-low inputs Ethernet/IP or Modbus TCP/IP

982EN 12 channels 0-35V DC, 0.5A/ch, low-side switches Ethernet/IP or Modbus TCP/IP, i2o

983EN 12 bi-directional input/output channels (any mix) same as 981EN inputs and 982EN outputs Ethernet/IP or Modbus TCP/IP, i2o output loopback

989EN 16 bi-directional I/O, 8 counter/timers 0-28V DC input/output, 32-bit 200Hz counters Modbus TCP/IP counter/timers w/ala rms

Analog I/O Modules

Model Analog Input Analog Output I/O Type Communication Protocol Special Functions

961EN, 962EN 6 channels, differential DC current or voltage Ethernet/IP or Modbus TCP/IP, i2o

963EN, 964EN 12 channels, single ended DC current or voltage Ethernet/IP or Modbus TCP/IP

965EN 4 or 6 channels Thermocouple Ethernet/IP or Modbus TCP/IP, i2o

966N 4 or 6 channels RTD Ethernet/IP or Modbus TCP/IP, i2o

967EN, 968EN 8 channels, differential DC current or voltage Modbus TCP/IP, i2o integrator/totalizer, sample avg.

993EN, 994EN 16 channels, single ended DC current or voltage Modbus TCP/IP integrator/totalizer, sample avg.

972EN, 973EN 4 or 6 channels DC current or voltage Ethernet/IP or Modbus TCP/IP, i2o

Page 8: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 8/24

OUTPUT MODULESINPUT MODULES

SWITCH

ETHERSTAX ETHERSTAX

ANY

ETHERNET

MEDIA

SWITCH

4-20mA, TC, or RTD

4-20mA 0-10V

ContactClosed

RelayClosed

Write input data

from remote sensors

to output devices

across any Ethernet 

media without a PC,

PLC, or any controller 

in between.

Acromag i2o® Peer-to-PeerCommunication Technology

The easiest way to link remote inputsto output devices without a controller

Many BusWorks 900EN and EtherStax

I/O modules have the ability to operate

like a long-distance transmitter using i2o

technology. Reproduce your sensor inputs

at Point A as 4-20mA control signals atPoint B. Or, monitor a discrete device at

one site by reproducing the level with a

relay at another location.

• Transmits data to/from any PLC, DCS,

recorder, or display device

• Reduces wiring costs by interfacing

many I/O signals over a single data line

without a controller in between

Use your existing Ethernet lines tosave time and wiring expenses

You can connect the input modules to

the output modules using your existing

network infrastructure or with a single

new cable. Multiple I/O modules can be

multiplexed through a switch or using

wireless radios.

• Supports wireless, fiber-optic, copper

and Internet media networks

Split a signal for transmission totwo different locations

Need the input data at two remote sites

simultaneously? No problem. i2o lets you

map an input to two output modules.

No complicated controllers.No software. No programming.

Acromag’s Ethernet I/O modules have

a built-in web page making it simple

to configure using your standard web

browser. Just click a few menu settings,

enter the IP addresses, and you are done.

For more information, visit our website at www.acromag.com/i2o

8 Call 877-214-6267 or 248-295-0880 for technical assistance.

ETHERNET I/O: PEER-TO-PEER

Page 9: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 9/24

9Visit www.acromag.com or e-mail us at [email protected]

 Acromag’s software

development tools

enable faster and 

easier deployment 

with trouble-free

communication

Development Software

These software development tools help

you quickly integrate Acromag I/O with

your application program.

OPC DA Server

This low-cost server is exclusively for use

with Acromag Modbus TCP/IP Ethernet

devices. The OPC Server connects

Acromag’s I/O modules to your HMI,

SCADA or custom-built Visual Basic / 

C++ applications. Easy CSV import / 

export capability saves development time

for faster deployment.

.NET / ActiveX Controls

These software controls provide a fast,

easy way to communicate with any

Modbus/TCP or Modbus/RTU slave

devices connected to your PC. Within

minutes, your Visual Basic, Visual C, .NET,Excel, or other compatible applications

will be talking Modbus protocol.

Function Libraries with C Source Code

Our C library of function routines speeds

framing of Modbus messages. Examples

help link your code with provided

function calls to configure, read, and

write to Acromag I/O modules. Ideal for

Windows, Linux, VxWorks, and QNX OS.

Ethernet Support Software Features

• High-Speed OPC connectivity to all AcromagModbus TCP/IP devices

• OPC DA Server supports all OPC-compliantHMI and SCADA applications

• ActiveX and .NET controls enable fast, easycommunication with any Modbus TCP/IP orModbus RTU slave device

• ActiveX and .NET controls support VisualBasic, Visual C++ and Excel applications

• Modbus C Libraries enable use with Linux,VxWorks, QNX, and other OS platforms

• Free evaluation versions

For more information, visit our website at www.acromag.com/ethernet_sw 

ETHERNET SOFTWARE

Ethernet and Modbus Software Development Tools

Model Description Program Environment Operating Systems

ACMBTCP-OPC Modbus TCP/IP Master OPC DA Server HMI, SCADA, Visual Basic, C++ Windows XP, Vista, 7, Server

AMTN, AMTX Modbus TCP/IP .NET / Act iveX Controls Visual Bas ic, C++, C#, Excel Windows XP, Vis ta, 7

AMRN, AMRX Modbus RTU .NET / Acti veX Controls Vi sual Basic , C++, C#, Excel Windows XP, Vista, 7

ESW-MBLIB Modbus C Library of Function Routines Visual C++ Win, Linux, VxWorks, QNX, OS-9

Page 10: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 10/24

These low-cost multi-

channel I/O modules

are ideal for remote

I/O applications with

limited space and 

those requiring a

handful of channels

in many locations.

BusWorks® I/O Modulesfor Modbus-RTU

Acromag’s BusWorks 900MB series is

a collection of analog and discrete I/O

modules with Modbus-RTU network

communication. BusWorks modules areideal for a wide variety of distributed I/O

applications including data acquisition,

control, process monitoring, and test &

measurement.

Analog input modules accept DC current,

voltage, or temperature sensor signals

and feature local limit alarm capabilities.

Analog output modules provide DC

current or voltage signals for local

displays, recorders, variable frequency

drives, valves, and other equipment.

Discrete I/O modules monitor and/or

control on/off status of industrial devices.

Windows® configuration software simpli-

fies module setup with easy selection of

input/output ranges, alarm setpoints, and

other operating parameters.

All 900MB Modbus I/O modules com-

municate over a high-speed RS-485 net-

work supporting data transfer rates up to

115K baud.

Inputs• Thermocouple • DC voltage• RTD/Resistance • DC current• Millivolt • AC current• Frequency • Discrete status

Outputs• DC voltage• DC current• Discrete switches or local limit alarms

Power• 10-36V DC• 24V AC

Approvals• CE, UL/cUL Class I Div 2 Groups ABCD

For more information, visit our website at www.acromag.com/modbus

10 Call 877-214-6267 or 248-295-0880 for technical assistance.

MODBUS-RTU: REMOTE I/O

Page 11: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 11/24

Analog InputModules

Multi-channel unitswith flexible I/O ranges900MB analog input modelsprovide an isolated network

interface for voltage, currentand temperature sensor signalsor for non-networked controllersignals. High-resolution, lownoise, A/D converters deliverhigh accuracy and reliability.

Highlights• Universal I/O ranges support

a variety of devices

• Differential inputs eliminateground loops

• Discrete outputs enablelocal limit alarms or host-controlled on/off switching

• Modbus-RTU high-speedRS-485 communication

Analog OutputModules

Control up to 4 deviceswith a single unit917MB/918MB models providean isolated network interface

for analog output signals.Outputs can be used to controlmechanical equipment or writeto display devices, data loggersand recorders, or to transmitdata to non-networked PLCsand controllers.

Highlights• Universal I/O ranges support

a variety of devices

• Discrete outputs enablelocal limit alarms or host-controlled on/off switching

• Modbus-RTU high-speedRS-485 communication

Discrete InputModules

Monitor 12 signalsper unit900MB discrete input modelsprovide an isolated network

interface for logic-level deviceswith active-high or low inputs.Inputs monitor on/off, high/low,or open/close status of motors,pumps, valves, heaters, fans,and other industrial equipment.

Highlights• 12 I/O channels in a single

inch-wide unit reducessystem costs and savespanel space

• Built-in pull-up/pull-downresistors simplify wiring andlower system costs

Discrete OutputModules

Control 12 devicesfrom one unit900MB discrete output modelsprovide an isolated network

interface to control logic-leveldevices with high or low-sideswitching. Outputs control on/off, high/low, or open/closestatus of motors, pumps, valves,heaters, fans, and other indus-trial equipment.

Highlights• Bi-directional I/O provides

level control and statusverification in one unit.

• Watchdog timers provide aconfigurable failsafe outputstate for use when host I/Ocommunication is lost

11Visit www.acromag.com or e-mail us at [email protected]

Analog I/O Modules

Model Analog Input Channels Analog Output Channels Discrete Outputs or Limit Alarms Communication Protocol

913MB/914MB 4 AC/DC current or DC voltage inputs 4 MOSFETs (1A, 0-35V DC) RS-485 Modbus-RTU

917MB/918MB 4 DC current or DC voltage outputs 4 MOSFETs (1A, 0-35V DC) RS-485 Modbus-RTU

924MB 4 thermocouple or DC millivolt inputs 4 MOSFETs (1A, 0-35V DC) RS-485 Modbus-RTU

932MB/934MB 2 or 4 RTD or resistance inputs 4 solid-state relays (1A, 0-48V DC) RS-485 Modbus-RTU942MB Frequency or pulse inputs 4 solid-state relays (1A, 0-48V DC) RS-485 Modbus-RTU

BUSWORKS 900MB SERIES

Discrete I/O Modules

Model Discrete Input Channels Discrete Output Channels Loop-back Monitoring Communication Protocol

901MB 12 active-low inputs (0-35V DC) RS-485 Modbus-RTU

902MB 12 low-side switches (0-35V DC) RS-485 Modbus-RTU

903MB 12 bi-direct ional I /O (any mix), act ive-low inputs, low-s ide switches Tandem I /O circuitry ver if ies output s tatus RS-485 Modbus-RTU

904MB 12 active-high inputs (0-35V DC) RS-485 Modbus-RTU

905MB 12 high-side switches (0-35V DC) RS-485 Modbus-RTU

906MB 12 bi-direct ional I /O (any mix) , act ive-high inputs, high-s ide switches Tandem I/O circuitry ver if ies output s tatus RS-485 Modbus-RTU

Page 12: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 12/24

BusWorks® I/O Modulesfor Profibus-DP

Acromag’s BusWorks 900PB series is a

high-performance line of network-ready

analog and discrete I/O modules. They

feature universal input/output ranges andan intelligent microcontroller to provide

extreme flexibility and powerful monitor-

ing and control capabilities. Select from a

variety of analog and discrete I/O models

to meet your application requirements.

Each module provides a direct network

interface for your I/O signals. Unlike

“block I/O” devices that combine large,

expensive processor blocks with snap-on

I/O terminal blocks, 900PB modules

handle the network interface and I/O

processing in one, compact multi-channel

module. This space-saving approach is

very cost-effective for systems that need

to add a small quantity of I/O channels at

existing control sites or network to new

remote sites.

To ensure high performance, modules

feature an advanced microcontroller

technology. On-board address switches

and automatic baud rate detection (upto 12 Mbps) simplify installation. Four-

way isolation prevents ground loops and

increases noise immunity. Indicator LEDs

and self-diagnostics help you quickly

catch problems.

Inputs• Thermocouple • DC current/voltage• RTD/resistance • AC current• Millivolt • Discrete level/status

Outputs• DC voltage• DC current• Discrete switches

Power• 12-36V DC

Approvals• Profibus PNO, CE, UL/cUL Class I Div 2

For more information, visit our website at www.acromag.com/profibus

12

Save up to 50%

compared to block 

and modular I/O

 systems. Acromag’s

BusWorks® modules

do not require special 

buscouplers, racks, or 

 power supplies.

Call 877-214-6267 or 248-295-0880 for technical assistance.

PROFIBUS-DP: REMOTE I/O

Page 13: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 13/24

13Visit www.acromag.com or e-mail us at [email protected]

BUSWORKS 900PB SERIES

Analog InputModules

Multi-channel unitswith flexible I/O ranges96xPB analog input modelsprovide an isolated network

interface for voltage, currentand temperature sensor signalsor for non-networked controllersignals. High-resolution, lownoise, A/D converters deliverhigh accuracy and reliability.

Highlights• Universal I/O ranges support

a variety of devices

• 12-channel stand-alonemodule is very cost-effective

• Differential inputs eliminateground loops

• -25 to 70°C operation

• Auto baud rate detection

• Industry-standard ASIC fornetwork compatibility

Analog OutputModules

Control up to 6 deviceswith a single unit972/973PB models providean isolated network interface

for analog output signals.Outputs can be used tocontrol mechanical equipmentor write to display devices,data loggers and recorders, orto transmit data to non-net-worked PLCs and controllers.

Highlights• Universal I/O ranges support

a variety of devices

• 6-channel stand-alonemodule is very cost-effective

• Selectable failsafe modes(0%, last-state, pre-defined)prevent unsafe conditions

• Profibus-DP high-speedRS-485 communication(up to 12M bps)

Discrete InputModules

Monitor status of up to12 channels per unit981/983PB discrete input mod-els provide an isolated network

interface for logic-level deviceswith active-high or low inputs.Inputs monitor on/off, high/low,or open/close status of motors,pumps, valves, heaters, fans,and other industrial equipment.

Highlights• 12 I/O channels in a single

inch-wide unit reducessystem costs and savespanel space

• Self-diagnostics monitormicrocontroller activity todetect operational failures(lock-up) and execute resetto restore communication

• Profibus-DP high-speedRS-485 communication(up to 12M bps)

Discrete OutputModules

Solid-state control of12 devices per unit982/983PB discrete outputmodels provide an isolated

network interface to controllogic-level devices with highor low-side switching. Outputscontrol on/off, high/low, oropen/close status of motors,pumps, valves, heaters, fans,and other industrial equipment.

Highlights• Bi-directional I/O provides

level control and statusverification in one unit.

• Selectable failsafe modes(0%, last-state, pre-defined)prevent unsafe conditions

• Watchdog timers provide aconfigurable failsafe outputstate for use when host I/Ocommunication is lost

Analog I/O Modules

Model Analog Input Channels Analog Output Channels Input/Output Ranges Communication Protocol

961PB/962PB 6 AC/DC current or DC voltage inputs 0-20mA DC, ±78mV to ±10V DC RS-485 Profibus-DP

963PB/964PB 12 AC/DC current or DC voltage inputs 0-20mA DC, ±1 to ±10V DC RS-485 Profibus-DP

965PB 4 or 6 thermocouple or DC mV inputs TC J, K, T, R, S, E, B, N; ±100mV, ±1V DC RS-485 Profibus-DP

966PB 4 or 6 RTD or resistance inputs Pt 100Ω, Ni 120Ω, Cu 10Ω; 0-500Ω RS-485 Profibus-DP

972PB/973PB 4 or 6 DC current or voltage outputs 0-20mA or 0-10V DC RS-485 Profibus-DP

Discrete I/O Modules

Model Discrete Input Channels Discrete Output Channels Loop-back Monitoring Communication Protocol

981PB 12 active-low inputs (0-35V DC) RS-485 Profibus-DP

982PB 12 low-side switches (0-35V DC) RS-485 Profibus-DP

983PB 12 bi-directional I/O (any mix ), active-low inputs, low-side switches Tandem I/O circui try verifies output status RS-485 Profibus-DP

Page 14: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 14/24

Acromag offers the industry’s best

selection of isolators. Dozens of models

are available to meet your requirements.

Select from single, dual, and quad-

channel models with AC, DC, or loop-

powered operation. Signal splitters

deliver dual outputs from a single source.

And whether you need a unit that sinks

or sources current, Acromag has the right

solution for you.

Optical or galvanic isolation eliminate

ground loop errors, reduce noise, and

block high voltage transient surges. All

Acromag isolators will withstand 1500V

AC for 60 seconds and provide continuous

250V AC or 354V DC common-mode

protection of your precious equipment.

Acromag features solve many toughproblems. Our multi-channel modules

reduce costs and save space. Models with

push-button calibration simplify installa-

tion and maintenance tasks. Units with

trim pots ship preset for 4-20mA input/ 

output so field calibration is not required.

Series 630T models offer isolated 24V DC

excitation on inputs to power your two-

wire transmitters.

Isolator Applications• Isolation• Amplification• Surge suppression• Sink/source power conversion

Inputs• 0-20mA DC• 0-100mA DC

• 4-20mA DC

Outputs• 0-20mA DC• 4-20mA DC

For signal converters or voltage transmitters, please see Page 16.

Isolation• Inputs, outputs, and power circuits are

isolated from each other• 1500V AC peak isolation

(250V AC or 354V DC continuous)

Power• 12-50V DC loop-powered (two-wire)• 10-36V DC (three or four-wire)• 115/230V AC (four-wire)

Approvals• CE, CSA, UL/cUL• Class I Div 2 Groups ABCD

For more information, visit our website at www.acromag.com/isolators

14

Save space and cut 

 your costs in half 

with multi-channel,

inch-wide units that 

 provide isolation and 

 surge protection on

up to four signals.

Call 877-214-6267 or 248-295-0880 for technical assistance.

ISOLATORS & SIGNAL SPLITTER

Page 15: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 15/24

15Visit www.acromag.com or e-mail us at [email protected]

600 Series Multi-Channel and Most Economical

Model Channels/Unit Input Ranges Output Ranges Power Isolation Configuration

610T single, dual, splitter 0-20, 4-20, 0-100mA DC 0-20, 4-20mA DC 10-36V DC 1500V AC self-ranging, push-button calibration

630T single, dual, splitter 4-20mA DC with 24V exc 4-20mA DC 15-36V DC, 90-250V AC 1500V AC factory calibrated, zero/span trim pots

650T single, dual, splitter 4-20mA DC 4-20mA DC 12-50V DC from output loop 1500V AC factory calibrated, zero/span trim pots

670T single, dual or quad 4-20mA DC 4-20mA DC input loop powered 1500V AC factory calibrated, zero/span trim pots

600 SERIES, FLAT PACK SERIES, 1500 SERIES

Multi-channelAC/DC-powered

Multi-channel unitswith flexible I/O ranges610T and 630T isolators arecompact and cost-effective to

deliver excellent performanceand great value. Signal splitterunits generate two identicaloutputs from a single input.

Highlights• Time-saving features include

auto-configuration and self-ranging inputs

• Push-button calibrationsimplifies field adjustmentsfor fast, easy maintenance.

• Capable of driving up to1000 ohm loads

Multi-channelLoop-powered

Isolate up to fourprocess loops per unit650T and 670T isolators arevery cost and space efficient.

Variety of units accommodatesink or source loop-poweredtwo-wire connections. PowerLEDs and a precision 10 ohmsense resistor provide power-ful diagnostic tools.

Highlights• 4-channel models reduce

costs and save space

• Signal splitter generates twooutputs from a single input

• Simple 2-wire connectionsfor easy installation

Single-channel2-, 3-, or 4-wire

Dozens of options tomatch your needsFlat Pack units provide classicanalog signal processing with

proven dependability. Thesebest-sellers are easy to useand require little maintenance.Full line of models can handlenearly any isolator applicationwith support for AC, DC, orloop power sources.

Highlights• Excellent accuracy, low drift,

RFI and EMI resistance

• Proven analog design withzero/span pot adjustment

• Low power consumption

Single-channelField-mount

Popular “hockey puck”for NEMA enclosures1500 series units are designedfor easy field mounting inside

rugged NEMA enclosures oron a control panel with DINrail. They are extremely stable,needing minimal maintenance.

Highlights• Select models draw power

from input or output loopsignal (sink/source current)

• Options include LCD display,HART interface, softwareconfiguration

• Excellent accuracy, stability

Flat Pack Series Analog InstrumentationModel Channels/Unit Input Ranges Output Ranges Power Isolation Configuration

270i single-channel 4-20mA DC 4-20mA DC input loop powered 1500V AC factory calibrated, zero/span trim pots

330i single-channel 4-20mA DC 4-20mA DC 10-36V DC, 4-wire 1500V AC factory calibrated, zero/span trim pots

340i single-channel 4-20mA DC 4-20mA DC 10-36V DC, 3-wire 1500V AC factory calibrated, zero/span trim pots

430i single-channel 4-20mA DC 4-20mA DC 115 or 230V AC, 4-wire 1500V AC factory calibrated, zero/span trim pots

1500 Series Field-Mount, Hockey-Puck Design

Model Channels/Unit Input Ranges Output Ranges Power Isolation Configuration

151T single-channel 4-20mA DC 4-20mA DC, optional display 12-50V DC from output loop 500V AC PC config., display push-buttons

155H single-channel 4-20mA DC 4-20mA DC, optional display 12-50V DC from output loop 500V AC HART, PC config., display push-buttons

Page 16: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 16/24

Acromag offers a broad assortment of

products to isolate, amplify, filter, and

convert measured signals from sensors

and other industrial devices. The isolated

transmitters condition and interface the

signal to your PLC, DCS, display, or other

process control instrumentation.

Isolation eliminates ground loop errors

and protects systems from surges.

Units convert temperature, resistance,

frequency, strain, and load sensor inputs

to proportional control signal outputs.

They also measure AC/DC voltage and

current signals representing pressure,

level, flow, and other process variables.

Acromag’s wide selection offers a choice

of features and performance to meet

most requirements. Programmable units

have many advanced signal processingcapabilities and offer the convenience of

Windows software configuration. Multi-

channel models reduce costs and save

space. And, push-button calibration

simplifies field maintenance.

Internal microprocessors deliver highly

accurate measurements with 16-bit A/D

and versatile output ranges in voltage,

current or HART formats.

Inputs• Thermocouple • DC voltage• RTD/resistance • DC current• Millivolt • AC current

• Frequency • Strain gage, load cell

Outputs• DC voltage• DC current

For 4-20mA isolators and signal splitters, please see Page 14.

Power• 12-50V DC loop-powered (two-wire)• 10-36V DC (three or four-wire)• 115/230V AC (four-wire)

Approvals• CE, CSA, UL/cUL• Class I Div 2 Groups ABCD

For more information, visit our website at www.acromag.com/transmitters

16

Select from dozens

of models to meet 

 your performance,

mounting, power,

and budget 

requirements.

Call 877-214-6267 or 248-295-0880 for technical assistance.

TRANSMITTERS & CONVERTER

Page 17: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 17/24

17Visit www.acromag.com or e-mail us at [email protected]

150T, 250/350/450T, 600T, 800T, ST130 SERIES

Field-MountTransmitters

For explosion-proof orNEMA 4X mountingLow-cost ST130 and universalinput 150T series transmitters

are PC-configurable (via USBor RS232) for easy setup andminimal maintenance. Optionsinclude an LCD display andsmart HART communication.

ProgrammableIntelligence

Software-configuredsignal processingIntelliPack transmitters are ourpremier line providing the best

performance and most signalprocessing capabilities. Easysoftware configuration speedsup commissioning and alsoarchives settings for reference.

Single or Dual-Channel Units

Cost, space-efficient600 series transmitters offergreat performance, channel-density and a fantastic value.

Select models for DC or loop-power. Time-saving featuresinclude auto-configuration,self-ranging inputs, and push-button zero/span.

Analog ProcessInstrumentation

Dozens of options tomatch your needsFlat Packs offer classic analogsignal processing with proven

dependability. Our best-sellersare easy to use and requirelittle maintenance. This seriescan interface nearly any input,output or power source.

IntelliPack 800T Series PC-Programmable with Push-Button Field Adjust

Model Input Ranges Output Ranges Signal Processing Functions Power Configuration

801T thermocouple, RTD, mV DC, ohms 0 to 20mA DC, 0 to 10V DC, alarm relay linearization, sqrt, average, limit alarm 10-36V DC PC config., push-buttons

811T ±100V DC, 0-22mA DC, 0-20A AC 0 to 20mA DC, 0 to 10V DC, alarm relay linearization, sqrt, average, limit alarm 10-36V DC PC config., push-buttons

841T 0 to 50KHz, 0 to 65535 pulses 0 to 20mA DC, 0 to 10V DC, alarm relay pulse counter, average, l imit alarm 10-36V DC PC config. , push-buttons

851T strain gauges, load cells, millivolts 0 to 20mA DC, 0 to 10V DC, alarm relay strain, lnrzr, avg, tare, bridge, limit alarm 10-36V DC PC config., push-buttons

Flat Pack 250/350/450T Series Analog Instrumentation

Model Input Ranges Output Ranges Signal Processing Power Configuration

250T thermocouple, RTD, AC/DC current/voltage, freq, ohms 4-20mA DC TC/RTD linearization 12-50V DC, output loop zero/span pots

350T thermocouple, RTD, AC/DC current/voltage, freq, ohms 4-20mA DC, LCD display TC/RTD linearization 10-36V DC zero/span pots

450T thermocouple, RTD, AC/DC current/voltage, f req, ohms 4-20mA DC, LCD display TC/RTD l inearization 115V or 230V AC zero/span pots

600T Series Multi-Channel and Most Economical

Model Input Ranges Output Ranges Signal Processing Power Configuration

610T DC voltage, DC current 0-20mA, 0-10V DC inverse output, self-ranging 10-36V DC auto-configuration, push-button calibration

650T thermocouple, RTD, DC current/voltage 4-20mA DC TC, RTD l inearization 12-50V DC, output loop zero/span pots , DIP switches, push-buttons

150T Series Head-Mount Universal Input Transmitters

Model Input Ranges Output Ranges Signal Processing Power Configuration

151T thermocouple, RTD, mV DC, resistance 4-20mA DC, LCD readout linearization, multifunction display 12-50V DC, output loop PC config., push-buttons

155H thermocouple, RTD, mV DC, resistance 4-20mA DC, LCD readout linearization, digital display 12-50V DC, output loop HART, PC config., push-buttons

ST130 Series Head-Mount (DIN Form B) Temperature Transmitters

Model Input Ranges Output Ranges Signal Processing Power Configuration

ST131 RTD, ohms 4-20mA DC RTD linearization 9-32V DC, output loop PC (USB) configuration

ST132 thermocouple, millivolt 4-20mA DC TC linearization 7-32V DC, output loop PC (USB) configuration

ST133 isolated thermocouple, millivolt 4-20mA DC TC linearization 12-32V DC, output loop PC (USB) configuration

Page 18: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 18/24

Acromag offers a full line of process

alarms for many applications. These units

monitor your setpoint limits for various

process parameters and trip a relay to

govern actions under alarm conditions.

Typical uses involve triggering warning

lights, audible alarms, or data loggers.Alarms can also turn devices on/off or

open/close valves. Advanced applications

are able to detect a deviation between

two signals, a rapid change in measured

values, or even capture a peak value for

a process.

Countless options accommodate avail-

able power sources, input signal types,

and relay connections. Flexible deadband

and delay adjustments filter out noise

and relay chatter to prevent false trips.

Other features include user-selectable

failsafe modes, and latching relays.

From the programmable IntelliPack

series to the economical Flat Pack fam-

ily, Acromag has an alarm unit to satisfy

most application requirements. Other

cost-effective alternatives are transmit-

ters with integrated alarms or remote

I/O modules for Modbus networks withbuilt-in trips for local alarm functions.

Inputs• Thermocouple • DC voltage• RTD/resistance • DC current• Millivolt • AC current• Frequency • Strain gage, load cell

Outputs• SPST, SPDT, or DPDT 5A relays

Power

• 12-50V DC loop-powered (two-wire)• 10-36V DC (four-wire)• 115/230V AC (four-wire)

Approvals• CE, CSA, UL/cUL, Class I Div 2 ABCD

For more information, visit our website at www.acromag.com/alarms

18

Reliable relay trips

for start-ups, safety 

 shutdown, level 

control, on/off 

 switching, early 

detection, and 

 process control 

 protection.

Call 877-214-6267 or 248-295-0880 for technical assistance.

LIMIT ALARMS

Page 19: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 19/24

19Visit www.acromag.com or e-mail us at [email protected]

INTELLIPACK 800A/800T, FLAT PACK, 900MB SERIES

Programmablealarm trips

Intelligent limit alarmand control functionsSmart and versatile, IntelliPackalarms can perform nearly any

function you require. Windowsconfiguration makes setup fastand easy. Push-buttons on thefront panel simplify calibrationadjustments out in the fieldwithout a PC.

Highlights• Six alarm/control functions

• Multi-channel alarm unitsare available

Transmitterswith limit alarms

Signal conversion andlimit alarm relaysIntelliPack transmitters includerelays for limit alarm functions

in addition to process currentor voltage output signals. Thecombination transmitter/alarmis very cost-effective and savesspace. The transmitters supporta wider variety of input typesthan standard alarm units.

Highlights• High or low setpoint limits

and configurable deadband

Analoglimit alarms

Potentiometer AdjustFlat Pack alarms offer classicanalog signal processing withproven dependability. They

are very economical and offerhigh performance. These best-sellers are easy to use andrequire little maintenance. AC,DC, loop-powered models.

Highlights• AC, DC and loop-powered

models available

• Process current/voltagealarms

Modbus-RTUlimit alarms

Multi-channel units900MB remote I/O modulescombine transmitter functions,alarm support, and a network

interface in a single, compactdevice. Each analog inputmodule provides up to fourdiscrete output channels foron/off control or limit alarmfunctions. The relays oper-ate under network control orbased on alarm setpoints.

Highlights• Up to four alarms per unit

IntelliPack 800A, 800T Series: PC-Programmable with Push-Button Field AdjustModel Input Type Output Type Power Configuration Alarm Trip Functions

801A thermocouple, RTD, mV, resistance single DPDT or dual SPDT 5A relays 10-36V DC software, buttons limit, window, on/off, rate, peak/valley

811A ±100V DC, 0-22mA DC, 0-20A AC single DPDT or dual SPDT 5A relays 10-36V DC software, buttons l imit , window, on/off , rate, peak/valley

812A dual input: DC voltage or current dual SPDT 5A relays 10-36V DC software, buttons limit, window, on/off, deviation, rate, peak/valley

822A dual input: thermocouple, mil livolt dua l SPDT 5A re lays 10-36V DC software, buttons limit, window, on/off, deviation, ra te , peak/va lley

832A dual input: RTD, resistance dual SPDT 5A relays 10-36V DC software, buttons limit, window, on/off, deviation, rate, peak/valley

8x1Ttemperature, voltage, current, ohms,freq., pulse, strain gauge, load cell

0 to 20mA DC, 0 to 10V DC, alarm relay(see Page 17 for more information)

10-36V DC software, buttons high/low setpoint limit alarm

Flat Pack Series: Analog Instruments with Pot Adjustments

Model Input Ranges Output Ranges Power Configuration Alarm Functions260A 4-20mA DC SPDT 2A dry contact relay 4.5V DC loop powered zero/span pots high/low setpoint limit alarm

361A 0-100V DC, 0-20mA DC, 0-20A AC single or dual SPDT 5A dry contact relays 10-36V DC zero/span pots high/low setpoint limit alarm

461A 0-100V DC, 0-20mA DC, 0-20A AC single or dual SPDT 5A dry contact relays 115V or 230V AC zero/span pots high/ low setpoint l imit alarm

BusWorks 900MB Series: Networkable Alarms for RS485/Modbus-RTU

Model Analog Input/Output Channels Discrete Outputs Alarm Trip Functions Communication Protocol

913MB/914MB 4 AC/DC current or DC voltage inputs 4 MOSFETs (1A, 0-35V DC) local l imit-based or network-controlled alarms RS-485 Modbus-RTU

924MB 4 thermocouple or DC mil livolt inputs 4 MOSFETs (1A, 0-35V DC) local limit-based or network-control led alarms RS-485 Modbus-RTU

932MB/934MB 2 or 4 RTD or resistance inputs 4 solid-state relays (1A, 0-48V DC) local limit-based or network-controlled alarms RS-485 Modbus-RTU

942MB Frequency or pu lse inputs 4 solid-state relays (1A, 0-48V DC) local limit-based or network-controlled alarms RS-485 Modbus-RTU

Page 20: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 20/24

These multi-purpose signal processor

modules feature universal input/output

ranges and an intelligent microcontroller

to provide an extremely flexible and

powerful standalone math computation

device.

Common uses include mathematical

calculations involving single or multiple

process variables, flow integrator/totalizer

functions, and conditional analysis with

boolean logic. Computations are output

as process signals, pulses, or pulse-width

modulated waveforms.

Math Functions• Add, subtract, multiply, divide• Square root, exponent (en), power (Xn)• Logarithmic (natural and base 10)

• Sine, cosine, tangent, and inverse• Absolute value• Minimum/maximum• IF, THEN, ELSE, AND, OR• >, <, =, ≠, ≥, ≤ • Input scaling• High/low signal selector/discriminator• Track and hold

• Integrator/totalizer

Windows software configuration

makes setup fast and easy. Equations

are entered as in a typical spreadsheet.

Diagnostics let you test equations and

display input/output values in engineer-

ing units in the configuration software.

You can even simulate conditions in the

configuration software. A simulation

window provides instant feedback to test

your equations so you can see the output

response before the actual installation.

Inputs• DC voltage• DC current• AC current

Outputs• DC current/voltage (0-10V or 0-20mA)

• Frequency (0-10KHz)• Pulse (10-36000 counts per hour)• Limit alarm (relay)

Power• 10-36V DC

Approvals• CE, UL/cUL Class I Div 2 Groups ABCD

For more information, visit our website at www.acromag.com/computation

20

Pre-process your data

without expensive

PLCs, controllers, or 

 software programs.

Our math modules

 perform custom

calculations and 

output the data as

 you need it.

Call 877-214-6267 or 248-295-0880 for technical assistance.

MATH & COMPUTATION

Page 21: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 21/24

21Visit www.acromag.com or e-mail us at [email protected]

INTELLIPACK 800M SERIES

DC Voltage orCurrent Output

Easy interface to pro-cess control devices892M/894M math modulesperform complex mathematical

computations and convert DCinput signals to scaled DC out-puts. They are ideal for isolatingand interfacing analog signalsto a PLC or controller as a volt-age or current input. Typicalapplications include calculatingsums, deltas, averages, flowrates, volumes, weight, power,and other scaled or computedvariables.

Highlights

• Universal DC voltage andcurrent input/output ranges

• Easy software configuration

• 200-character equationfields for transfer functions

• Software displays signalvalues in engineering units

• Track and hold functionholds output signal at asignificant value indefinitely

• Simulation feature allowsoff-line testing of equations

• Excitation supply for two2-wire transmitters

• Class I Division 2 approvals

Frequency orPulsed Output

Ideal for integrator andtotalizer applications895M/896M frequency outputmodels are ideal for integrator/

totalizer applications. Using apulsed output with an externalcounter calculates flow rates,volume, weight, and power.IntelliPacks support ultra-lowfrequency pulses down to10pph. Adjustable zero dropoutlevels apply minimum inputthresholds to filter out noiseand unwanted pulses.

Highlights• Universal DC voltage and

current input ranges• Frequency or pulsed output

• Easy software configuration

• 50-character equation fieldsfor transfer functions

• Supports integrator/totalizerapplications to calculateflow, volume, weight, power

• Pulse-width modulationcapability

• Solid-state relays for on/offcontrol or local alarms

IntelliPack 800M Series

Model Input Ranges Output Ranges Control Relays Power Configuration

892M, 894M dual/quad input: 0-20mA, 0-10V DC single output: 0-20mA, 0-10V DC n/a 10-36V DC software-configured

895M, 896M single/dual input: 0-20mA, 0-10V DC single/dual output: 0-10KHz, 0-36,000 counts/hr single/dual SSRs (60V DC, 0.5A) 10-36V DC software-configured

Easy configuration menus with drop-down selection lists.

Intuitive, spreadsheet-style entry of your custom equations.

Simulate equations off-line to test output signal response.

Page 22: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 22/24

22

From panel meter 

displays to power 

 supplies to mounting

hardware, Acromag

 gives you convenient 

one-stop shopping

for all of your I/O

needs.

Call 877-214-6267 or 248-295-0880 for technical assistance.

Panel Metersand Displays

APM765 Panel MeterThese low-cost panel meters

display data collected fromprocess current, DC volt-age and temperature inputs.Several output options canconvert the display into atransmitter with proportional4-20mA output or a Modbusinterface. A relay outputoption adds limit alarm andpump control capabilities.

Process inputs can be scaledfor virtually any engineering

units. Temperature inputs candisplay in °F or °C.

Set up is very easy using thesimple four-button configura-tion interface. The meter isalso programmable using a PCand MeterView software.

Highlights• Universal input accepts

TC, RTD, mA DC, V DC

• 4-20mA output or Modbus-

RTU interface• Optional relays for limit

alarms or pump control

• Single or dual 24V DCexcitation supplies

• Sunlight-readable display

• Universal AC/DC power

• CE, UL/cUL

Rack-MountI/O Modules

8B Signal ConditionersThe 8B line of isolated analog

signal conditioners provides95 I/O modules for interfacinga wide variety of voltage,current, temperature, position,frequency and strain measure-ment devices. Despite theirdiminutive size, 8B modulesoffer big performance.

These rack-mounted I/O mod-ules are ideal as an isolatedfront-end for your embeddedcontrollers or other instrumen-

tation that cannot accept low-level sensor inputs.

Highlights• 1/5th the size of competing

signal conditioners

• Excellent accuracy andsignal linearity for reliablemeasurements

• High voltage isolationprevents ground loopsand reduces signal noise

• High-level transient andsurge suppression protectcontrol systems

• Filtering provides effectivenormal and common modenoise rejection

• Wide operating temperaturerange for extreme climates

• CE compliance and otherapprovals pending

CommunicationAccessories

Network RepeatersAcromag’s RS-485 network

repeater device allows usersto take full advantage of theRS-485 standard’s extendedcommunication distances andmulti-dropping capabilities.

The units offer field selectableEnd-of-Line Network (EOLN)terminations on both the Aand B networks. Operation istransparent to all devices andno handshaking is required.Up to thirty two RS-485

devices can be driven.Highlights• Designed for use with

Johnson Controls N2 orBACnet bus

• Isolates and boosts RS-485network signals

• Add 32 nodes and 4000 ft.

• Transparent operation

• Three models for operation

on 24/115/230V AC power• No separate transformer

required with 24V AC units

www.acromag.com/panelmeters www.acromag.com/8b www.acromag.com/repeaters

SPECIALTY INSTRUMENTS

Page 23: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 23/24

23Visit www.acromag.com or e-mail us at [email protected]

PowerSupplies

PS5R-S Slimline SeriesThe PS5R-S series is the new

standard in switching powersupply technology. With sleek,compact ergonomics, allinternational standards andapprovals, and an incrediblerange of inputs, the PS5R-Smakes your power supplychoice a simple one. CarryingUL listing, CE marking, andTÜV certification, Acromaghas your needs covered.Add to these approvals anamazing range of AC and DC

input voltages, and you haveunbeatable versatility.

Highlights• Full line for 10 to 240W

power output

• Universal AC/DC input:85-264V AC, 100-370V DC

• DIN rail or panel mount

• Unique spring-up terminals

• IP20 protection

• CE marked

• UL, cUL, and TÜV approvals

• UL 508 listed

• UL 1604 listed:Class 1, Div 2, Groups ABCD

• Meets EN 50178

• EMC: EN 61204-3

• LVD: EN 60950

SoftwareSupport

Utilities and DriversAcromag’s software tools

simplify your I/O integration.Our configuration softwarespeeds set up of I/O modules.Interface packages providefunction libraries to developapplications. Developer kitsinclude C source code andare ideal for Windows (VisualC), Linux, VxWorks, and QNX.Drivers provide device profilesfor easy commissioning.

Highlights

• OPC DA Server• .Net / ActiveX Controls

• C library for Modbus TCP/IP

• Configuration software

• Configuration copy utilities

• .eds files for Ethernet/IP

• .gsd files for Profibus-DP

HardwareAccessories

Mounting AccessoriesFor your convenience,

Acromag offers a variety ofmounting hardware.

• 19-inch rack-mount kits andpre-cut DIN-rail strips

• Industrial NEMA-4/12 oiland water-tight enclosures

• Stainless-steel NEMA-4Xhousings for food industry

• Explosion-proof housing forfield-mount transmitters

• Optional terminal blocks foreasier wiring

Adapters and CablesFor your convenience,Acromag offers a variety ofwiring accessories.

• USB isolators

• USB to serial converters

• USB and serial cables

Custom Servicesand Approvals

Calibration, Tags, andProtective Coatings

Over the past 50 years, we’vebeen able to service manycustomers’ unique needs withmodifications to standardmodels. Acromag can alsoprovide services to save youtime commissioning units forinstallation in the field.

• Long list of modified modelsfor special ranges/functions

• Factory calibration servicesand skilled repair technicians

• Identification tags andprotective coatings

• Certificates of compliance,test data certificates, andcertified drawings

Safety ApprovalsMost Acromag productsfeature safety certificationsfor approved use in industrialapplications. Many models aresafe for hazardous locations.

• UL listed in USA, CanadaCE marked for Europe,ATEX approvals,CSA certifications

• Class I; Div 2; Groups ABCD

• EtherNet/IP conformance

• Modbus TCP/IP conformance

• Profibus Nutzer Organisation

www.acromag.com/power www.acromag.com/software www.acromag.com/accessories www.acromag.com/services

ACCESSORIES AND SPECIAL SERVICES

Page 24: Product Summary Guide 352

7/31/2019 Product Summary Guide 352

http://slidepdf.com/reader/full/product-summary-guide-352 24/24

8400-352h © Acromag, Inc. 2011. Data subject to change without notice. Pr inted in USA 5/2011

Visit us at www.acromag.com!

• Product data sheets, manuals, and price information

• Order online with your credit card or purchase order

• Technical support, tutorials, and application notes

• Subscribe to our monthly e-newsletter

DEPENDABLE VALUE.