Monkeytoe Non-caged LadderPermanent non-caged access ladder system that provides safe and easy accces to elevated
areas with or without ladder stiles to extend 1000mm or more above landing surface.
TYPICAL USES / APPLICATIONS • Access requirements with heights that don’t
exceed 4000mm
• Rooftop access
• Plant maintenance platforms
• Ceiling spaces
• Industrial tank access
• Hospitals, office blocks, sports centre
CHARACTERISTICS / ADVANTAGES • Unique rung profile design makes ladder comfortable and
easy to climb
• Low maintenance and neat appearance
• Modular design for fast and easy install
• Propietary product with engineering, and pre-configued to
code compliance dimensions
• High level of safety and confidence for maintenance personal
• Single person use, 150kg rated
• Stress load tested – 1.8kN applied at 75º
PRODUCTDESCRIPTION
TECHNICAL DATA / MATERIALS
• All componentry and accessories manufactured from high grade structural aluminium
• Product can be powder coated
• Fixing requirements:
• Steel purlin
- 2 x M1O S/S bolts OR
- 2 x M8 toggle bolts OR
- 3 x 14G tek screws (2mm min purlin thickness)
• Steel structure
- 2 x M1O S/S bolts
• Concrete (Min 25MPa)
- 2 x (12mm x 100) tru-bolt OR
- 2 x (10mm x 100) screw bolt
• Brick
- 2 x (10 x 100) screw bolt
• Composite panel
- 2 x 10mm through bolt with spreader plate on rear, OR
- 2 x M8 toggle bolts
Monkeytoe Non-caged Ladder | LD011/7
PRODUCT SPECIFICATION SHEET
CODE: LD01
Monkeytoe Non-caged Ladder | LD012/7
TESTS APPROVALS / STANDARDS• Structural design action B1
• AS/NZS 1170 Standards Australia / New Zealand (Relevant parts)
• Aluminium Structures, Part 1: Limit State Design AS/NZS 1664.1 Standards Australia / New
Zealand NZS/AS 1657
WARRANTY Lifetime Warranty (10 years)
MAINTENANCE • It is recommended that plant platforms are included in the standard ‘building warrant of
fitness’ inspections.
• All damage or loose fixings to be reported immediately to asset manager or building owner
for correction.
REFERENCE
Monkeytoe Non-caged Ladder | LD013/7
Monkeytoe Non-caged LadderLD01
A3
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nz
Th
is dra
win
g a
nd a
ssocia
ted
desig
n is th
e co
pyrig
ht a
nd
pro
pe
rty of M
onke
ytoe L
td. It sh
all n
ot b
e u
sed
for a
ny p
urp
ose
or p
roje
ct, with
ou
t prio
r writte
n co
nse
nt o
the
r tha
t desig
na
ted
by M
on
keyto
e L
td.©
2004-LAD-NC-01
Non Caged Ladder
SHEET 1 OF 1
REV:01SCALE: 1:25
1/06/2018
MONKEYTOE
1
DETAIL 11:2.5
2
DETAIL 21:2.5
525 I/S
600 O/S
30
0
90
0 m
in.
110
0 m
ax.
FIXINGS Metal - M8 Bolt Timber - M10 Coach Screw Concrete - M10 Concrete Screw Purlins - 75mm TEK Screw
PROFILEDALUMINIUM
RUNG
NOTES:
DESIGNED IN ACCORDANCE WITH - AS/NZS 1170 - AS/NZS 1657:2018 - AS/NZS 1892:1996 - B! & B2 DURABILITY CODES - RELEVANT STATUTORY OHS CODES OF PRACTICE
WORKING LOAD LIMIT: 150kg
200 min.940 max.
60
00
ma
x.
ALUMINIUM LADDER
ALUMINIUM FIXING BRACKET(REFER TO LADDER FIXING
BRACKET DRAWINGS)
24
00
ma
x.
A3
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nz
Th
is dra
win
g a
nd a
ssocia
ted
desig
n is th
e co
pyrig
ht a
nd
pro
pe
rty of M
onke
ytoe L
td. It sh
all n
ot b
e u
sed
for a
ny p
urp
ose
or p
roje
ct, with
ou
t prio
r writte
n co
nse
nt o
the
r tha
t desig
na
ted
by M
on
keyto
e L
td.©
2004-LAD-NC-02
Non Caged Ladder with Stiles
SHEET 1 OF 1
REV:01SCALE: 1:50
1/06/2018
MONKEYTOE
525 I/S
600 O/S
30
0
60
00
ma
x.
1
DETAIL 11:2.5
2
DETAIL 21:2.5
ALUMINIUMLADDER
ALUMINIUM FIXING BRACKET(REFER TO LADDER FIXING
BRACKET DRAWINGS)
PROFILEDALUMINIUM
RUNG
ALUMINIUMEXTENDABLE STILESSLIDE DOWN WHEN
NOT IN USE
200 min.940 max.
FIXINGS Metal - M8 Bolt Timber - M10 Coach Screw Concrete - M10 Concrete Screw Purlins - 75mm TEK Screw
24
00
ma
x.
11
00
ST
ILE
TR
AV
EL
NOTES:
DESIGNED IN ACCORDANCE WITH - AS/NZS 1170 - AS/NZS 1657:2018 - AS/NZS 1892:1996 - B! & B2 DURABILITY CODES - RELEVANT STATUTORY OHS CODES OF PRACTICE
WORKING LOAD LIMIT: 150kg
M10x100 S/STEELCONC. SCREW BOLT
ASSEMBLY CONFIGURATIONS
800
600 - 1000
604
AA
75x6 EA6261-T6 AL
50x6 FB5052 AL
9 THRU
30
35
B
B
SECTION A-A
800
3 x 9 THRU
245 245
0
57
302
547
604
SECTION B-B
M8 X 60mm MUSHROOM HEAD S/STEEL COACH BOLT
M8 X 25mm S/STEEL BOLT
M10 X 60mm S/STEEL COACH SCREW
14G x 75mm Galv.TEK SCREW
A3SCALE 1:7
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nzREV:02
MONKEYTOE
This drawing and associated design is the copyright and property of M
onkeytoe Ltd. It shall not be used for any purpose or project, without prior w
ritten consent other that designated by Monkeytoe Ltd.©
01/05/2015LD421.600-1000
SHEET 1 OF 1
LADDER BRACKET - 600-1000mm
M10x100 S/STEELCONC. SCREW BOLT
ASSEMBLY CONFIGURATIONS
616
280-400
604
AA
75x6 FB5052 AL
50x6 FB5052 AL
30 37.
5
9 THRU
B
BSECTION A-A
37.
5
9 THRU
245 245
0
63
308
553
616
SECTION B-B
M8 X 60mm MUSHROOM HEAD S/STEEL COACH BOLT
M8 X 25mm S/STEEL BOLT
M10 X 60mm S/STEEL COACH SCREW
50x6 FB BRACINGNOT USED FORBASE MOUNT
14G x 75mm Galv.TEK SCREW
A3SCALE 1:5
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nzREV:02
MONKEYTOE
This drawing and associated design is the copyright and property of M
onkeytoe Ltd. It shall not be used for any purpose or project, without prior w
ritten consent other that designated by Monkeytoe Ltd.©
01/05/2018LD421.280-400
SHEET 1 OF 1
LADDER BRACKET - 280-400mm