www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
Microprocessor-based Protection Relays
SYMAP®ProductOverviewSYMAP® is a flexible microprocessor-based digital protection and control device for use in low,medium,andhigh-voltagepowersystems.Becauseofitsintegratedprotectionfunctionsandhuman-machine interface capabilities, it is an efficient and cost-effective solution for all types ofswitchgears.With threepowerfulmicroprocessors, SYMAP®offers completeprotectionand controlfunctions for generators,motors (synchronous and asynchronous), transformers, power lines, anddistributions.Allprotectionfunctionscanbeactivatedsimultaneously,andtherearenolimitsinusingallofthematthesametime.WithSYMAP®,fivemainbreakercontrolscanbeactivatedwithallthenecessaryfunctions,suchasdisplay, control, and blocking, for optimal breaker management. A small integrated PLC allowsindividualinterlocksofcontrolcommands.Forflexibilityincommissioningandduringuse,bothdigitalandanalogoutputscanbeusedtoconnecttheSYMAP®controlunittomainswitchboardcontrols.Additionally, a variety of serial interfaces with different kinds of data protocols can be used forcommunicationbetweenSYMAP®unitsandthecentralcontrolsystem.Fordiagnosticsandmonitoring,SYMAP®hasthreemicroprocessorswhichsuperviseeachother,andprovidingawatchdogsystem.Importantfunctionsarelaidoutinadoubleredundancycombination,operatingindependentlywiththesecondprocessor.Connectedseparately,anoptionalunitforshortcircuitprotectionoperatesparalleltotheSYMAP®deviceandwilldosoevenifthepowersupplyfails.
www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
SYMAP®HumanMachineInterface
SYMAP®iseasytoprogramandoperate.AlargegraphicLCDwithoptionalLEDindicatorsconveysimportantdata,suchaspositionofallconnectedbreakers,parametersettings,andeventhistory,ataglance.Graphicsandmeasurementdataaredisplayedside-by-sideontheLCD,andtheuserdoesnothavetoswitchbetweenpages.Theprogrammingisbuiltinandismenu-treedriven,makingsettingparametersanintuitiveprocess.Besidetheoptionofdoingthewholedeviceconfigurationbyapplicationsoftware“SYMAPParameterTool(SPT)”,itispossibletosetallavailableparametersbythekeysofthefrontpanel.Usingalaptopofferscertainadvantages,suchasparameterdatastoredinthelaptopcanbeeasilyinputintootherSYMAP®units.Eitherway,easeofprogrammingisguaranteedandon-sitevisitsbythemanufacturer'sengineersduringcommissioningarenotrequired.SYMAP®providesfourhotkeysundertheLCDofferingaccesstofourgroupsofvalues: - Meters - Alarm - Process - BreakerControlTheusercanpressthehotkeystoscrollthroughpagesofinformationpertainingtothesevalues.Underthehotkey"Meters,"detailedinformationofelectricmeasurementvalues,countersforactiveandreactivepower,andworkinghoursisprovided.Byrthehotkey"Alarms,"allactivealarms,eventstores,andblockingsaredisplayed.Under"Process,"allprocessdata,suchassynchronizationdisplay,motorthermalindication,andbreakercounters,areshown.Under"BreakerControl,"uptofivebreakerscanbeaccessedandcontrolled.Whenprogrammingbreakercontrols,theuserhasaccesstovariouslayoutconfigurationswhichareavailablethroughalibraryofgraphicsmaintainedwithinSYMAP®.Programmedblockingsremainactivewhenmanualcontrolofthebreakerisused.Furthermore,eachofthehighlightedbreakersintheLCDcanbecontrolledbythekeys"O"and"I."Forsecuritypurpose,accesstoSYMAP®'sparametersandbreakercontroldataofSYMAP®isprotectedbyacodesystem.Thecodesystemoffersdualaccess:byatranspondercardorbypasswordinput. SYMAP®TerminalConnections
www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
AllconnectionstoSYMAP®aremadewithterminalplugsonthebackofthedevice,allowingthedevicetobeexchangedeasily.Theterminalblocksaredividedintofourgroups.
AnalogVoltageandCurrentMeasurementSYMAP®providesvariousanaloginputsforvoltageandcurrentmeasuringbyconventionalpotentialtransformers(PTs)andcurrenttransformers(CTs)attherearofthedevice.IfterminalplugsfortheCTsaredisconnected,thecircuitswillbelinkedautomatically,thus,thereisnodisconnectionintheCTcircuitloops.Atotalof17analoginputsforcurrentandvoltagetransformersareusedforprotectionfunctions.ThefollowinglistshowspossibleconnectionsforCTsandPTs:- 3xCTforfeedercurrent- 3xCTfordifferentialcurrent- 2xCTforgroundcurrent- 3xPTforfeedervoltage- 3xPTforbusbar1voltage- 3xPTforbusbar2voltage- 2xPTforgroundvoltageIncaseofusingcombinedsensors,SYMAP®provides:- 3xforfeedercurrent- 3xforfeedervoltageCommunicationSYMAP®canserveasthemainbaycontrollerforthepowermanagementsystemorsubstationsystem.ThefollowinglistshowsthestationsystemitemsofferedbySYMAP®:- Remotesupervision- Remotecontrol- Remoteparametersetting- Centralregistrationofmeasuredandcalculatedvalues- Centraleventlogging- Centralfaultrecording,analysisandlogging- Plantpowermanagement
www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
COMMUNICATIONINTERFACESSYMAP®canserveasthemainbaycontrollerforthepowermanagementsystemorsubstationsystem.Itprovidescommunicationportsavailablewiththefollowinginterfaces:• RS232onthefrontpanelforprogramminganddataoutput• 1CANBUS1(factoryprotocol)• 1CANBUS2forengine• RS422/RS485portport(ModbusRTU)• iberopticinterfaces(Linediff.Protection/SCADA)
PROTOCOLS• CANBUS1(factoryprotocol)• CANBUS2(enginecontrol:CATERPILLAR,DEUTZ,MTU,VOLVO,...)• PROFIBUSDP• MODBUSRTU• IEC60870-5-103• IEC61850ExtendedBoard(Optional)AnextendedboardcanbeconnectedtoSYMAP®,providingadditionalinputandoutputchannels.Theextendedboardiscustomizedtoindividualclientrequirementsandcanbeequippedwithamaximumofthefollowinginputandoutputchannels:- 36digitalinputs- 24relayoutputs- 8analogoutputs4...20mA- 21analoginputsPT100/PT1000oranaloginputs4...20mA
www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
SYMAP®RecordingunitSYMAP®'srecordingunitcontainsuptothreeseparateparts:1) Eventhistory,2) Detailedprotectionfunctionhistory3) Eventdatarecorder(optional)Regardlessofpowersupply,dataaretobesavedinthenon-volatilememory.AlldatarecordedSYMAP®canbetransferredandanalysedviaapplicationsoftware“SYMAPParameterTool(SPT)”- Protectionfunctionevents,suchasactivationandeventualintervention- Thechangeofbinaryinputsandoutputs- ThecontrolofLocal/SCADA- Thechangeofeachswitchingdevice- ON/OFFcommandsbycentralpowermanagementsystem- Anyattemptortrailtogiveacommandprohibitedbyinterlocking- Anyalarmsignal(alsofromdiagnostics)- DatalogsformeasurementinputsEventHistorySYMAP®automaticallycollectsandstoresallactivatedeventsindicatingtheirnumber,title,coming/goingstatus,andtimestamp.Amaximumof5,000eventscanbestored.Incaseofoverflow,dataoverwritingoperatesaccordingtothefirst-in-first-out(FIFO)principle.DetailedProtectionFunctionHistorySYMAP®automaticallycollectsandstoresallactivatedeventsreferringtoprotectionfunctionswithatimestamp.- Eventnumber- Eventtitle- Timestamp- Pickuportripvalue(withfaultphaseindication)- Settingvalue- Triptime- 3-linevoltageandcurrentpickup,synchronizedwiththetripeventAmaximumof1,000protectionfunctioneventscanbestored.Incaseofoverflow,dataoverwritingoperatesaccordingtothefirst-in-first-out(FIFO).
www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
DataRecorder(Optional)
Thedatarecordercanlog16analoginputs,14digitalinputs,and12digitaloutputs.Therecorderhasthefollowingsettings:- Numberofsamples(6-72)- Recordingperiod(5-60sec)- Pre-trigger(0-100%)- Triggerevent(stopforrecorder)Therecordingperioddependsonthesetnumberofsamples.Therecordercanbesetwithapre-triggertimetologthefaultlessperiodofafault,too.Stoppingtherecordercanbetriggeredeitherbyaneventorbyapre-settime.Foreasiermanagementandtrouble-shooting,eventdatacanbetransferredandanalysedviaPCornotebook.AserialinterfaceontheSYMAP®frontpanelservesasacommunicationport.DiagnosticsandMonitoringSYMAP®hasthreemicroprocessorsthatsuperviseeachother,providingawatchdogsystem.Importantfunctionsarelaidoutinadoubleredundancycombination,operatingindependentlywiththesecondprocessor.Connectedseparately,anoptionalunitforshortcircuitprotectionoperatesparalleltotheSYMAP®deviceandwilldosoeveniftheentirevoltagefails.SYMAP®providesvariousdiagnosticandmonitoringfunctionsasfollows:- Allmemories(ROMs,RAMs,EEPROMs)- Allanalogreferencevoltages- Automatedtestsequences- ControlpowerON/OFFofSYMAP®- Binaryinputandoutputforcontrollogic
www.stuckegroup.comPS.SYMAP.GI.ENG.REV0
ProductSheet
ThefollowingsupervisingsystemsareofferedbySYMAP®:- Self-diagnosticsofSYMAP®- Theinputsofanalogdata(auxiliarycircuit)- Thestatusandpositionofswitchingdeviceandmotor'son-offstatus- Supervisingsupplyoftripcoil- Gaspressure- Temperatureinsidepanel- Eachoperatinglifeofbreaker(hours)SYMAP®DigitalProtectionDeviceTherearethreetypeofSYMAP®unitsasfollows:- SYMAP®-YEssentialcosttype- SYMAP®-XBasictype- SYMAP®-BCBasictypeexpandedtoincludeLEDindicators,