<<< www.dialab.at PRODUCT RANGE 2015

PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

  • Upload
    vokhue

  • View
    232

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

<<<

www.dialab.at

PRODUCT RANGE 2015 www.dialab.at

Page 2: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

More than 40 years of experience

DIALAB® GmbH was founded in 1972. The company with its headquarters and main plant, located south of Vienna in Wr. Neudorf, Austria, is a manufacturer and distributor of Diagnostics and Laboratory Equipment – it offers the widest range of Laboratory Diagnostics worldwide.

We dedicate ourselves exclusively to supporting the clinical laboratory and to supplying a complete range of products, based on 3 product lines, namely Clinical Chemistry Reagents, Immunological Reagents and Coagulation Reagents. Presently, DIALAB® supplies its wide product range to more than 100 countries around the world. Active around the globe

Including 4 subsidiaries, located in the Czech Republic, Hungary, Serbia and Slovak Republic we are a total of over 80 employees, we are ISO 13485:2012 certified and a great number of our products is CE-marked.

We are engaged in business relations worldwide, we have production and research facilities in Wr. Neudorf, Austria and Prague, Czech Republic.

OEM / BULK

We offer different options for our OEM partners. Generally, DIALAB® can provide reagents in bulk, customised kits, labelled vials or unlabelled vials.

Product Training

DIALAB® offers training programs in its head-quarter in Wr. Neudorf in order to support its customers.

Applications

Suggested application procedures for DIALAB® reagents are available for most analysers.

Customer Service, Orders and Pricing

Contact your DIALAB® Distributor or contact DIALAB® directly at: Phone: +43 / 2236 / 660910 0 Fax: +43 / 2236 / 660910 30/31 e-mail: [email protected] website: www.dialab.at

DIALAB® will assist you by telephone, fax or e-mail with any information related to our products.

Warranty

DIALAB® products are warranted to perform according to the procedures described in the instruction insert accompanying the product. Changes or modifications of the product may adversely affect the stated performances. DIALAB® shall not be liable for any damages arising out of incorrect use of the products.

1972 – 2012

COMPANY PROFILE

Page 3: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

<<<

www.dialab.at

INSTRUMENTS<<<

DIAGNOSTICS

IMMUNOTURBIDIMETRY 4

THERAPEUTIC DRUG MONITORING 6

DOA (DRUGS OF ABUSE) LIQUID 6

CLINICAL CHEMISTRY 2

DIAQUICK RAPID TESTS 7

URINE STRIP ANALYSERS 17

COAGULOMETERS 19

COAGULATION ANALYSER 23

PHOTOMETERS 24

CLINICAL CHEMISTRY ANALYSERS 26

ELISA READER / WASHER 30

AUTOMATED ELISA SYSTEMS 32

BLOOD GLUCOSE & HEMOGLOBIN TESTING 36

SEROLOGY 10

ELISA TESTS 11

BLOOD GROUPING AND RHESUS TYPING 14

COAGULATION AND FIBRINOLYSIS 15

URINE STRIPS 16

Page 4: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<CLINICAL CHEMISTRY Reagents

2

Reagents

Adenosine Deaminase (ADA), enzym., color.

Albumin, BCG

Alkaline Phosphatase, opt. DGKC

Alkaline Phosphatase, mod. IFCC

α-Amylase, mod. IFCC

α-Amylase, CNP-G3

α-Amylase Pancreatic, ET-G7PNP

Ammonia, enzymatic, UV

Bile Acids, enzymatic cycling

Bilirubin Auto Direct, DCA

Bilirubin Auto Total, DCA

Bilirubin Direct, Jendrassik Grof

Bilirubin Total, Jendrassik Grof

Bilirubin Direct/Total, Jendrassik Grof

Calcium, Arsenazo

Calcium, CPC

Carbon Dioxide (CO2), PEP-C

Chloride, Mercuric Thiocyanate

Cholesterol, CHOD-PAP

Cholesterol HDL PrecipitantCholesterol LDL PrecipitantCholesterol HDL Direct, immunoinhibition

Cholesterol LDL Direct, enzym. select. protection

Cholinesterase, opt. DGKC

CK-MB, opt. DGKC / IFCC

CK-NAC, opt. DGKC / IFCC

Copper, 3,5-DiBr-PAESA

Creatinine, mod. Jaffé

Creatinine, enzymatic, PAP

Ethanol, enzymatic, UV

Fructosamine, NBT

G6PDH, UV, kinetic (dry powder)

G6PDH Deficiency Screen, qualitative, visual (dry powder)

Gamma GT, Szasz, stand. to IFCC

GLDH, DGKC

Glucose, GOD-PAP

Glucose, Hexokinase

GOT (AST), mod. IFCC

GPT (ALT), mod. IFCC

HbA1c Direct, immunoturbidimetric

HbA1c, ion exchange

α-HBDH, opt. DGKC

Haemoglobin Total, Cyanmethaemoglobin

Homocysteine, enzymatic cycling

β-Hydroxybutyrate, enzymatic, NBT

Iron, Ferene

Lactate, enzymatic, UV

LDH-L, IFCC

LDH-P, opt. DGKC

Lipase, enzymatic, colorimetric

Lithium, enzymatic

Magnesium, Xylidyl blue

NEFA, ACOD-PAP

Phosphorus Inorganic, Molybdate

Potassium, enzymatic

Protein Total, Biuret

Protein Total Mono, Biuret

Protein Total in Urine/CSF, Pyrogallol red

Sodium, enzymatic

Triglycerides, GPO-PAP

UIBC, Ferene

Urea, Urease/colorimetric

Urea UV Auto, Urease/GLDH

Uric Acid AOX, enzymatic, colorimetric Uric Acid TBHBA, enzymatic, colorimetric 25-OH Vitamin D, enzymatic

Zinc, 5-Br-PAPS

Also available as system packs for Autolyser, BT Series, Hitachi, Advia, Kone, Olympus, Beckman.

new

Concentrated reagents for Olympus available for: Cholesterol, Glucose, GOT(AST), GPT(ALT), Triglycerides and Urea.

new

new

Page 5: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<< CLINICAL CHEMISTRY Calibrators & Controls

3

Calibrators Diacal Auto (multi calibration serum, human)

Diacal Lipids (lipid calibration plasma, human) Diacal CK-MBADA Calibrator Ethanol Calibrator/Control SetFructosamine CalibratorHaemoglobin Total CalibratorHbA1c Direct Calibrator, 4 level series

HDL-Cholesterol CalibratorLDL-Cholesterol CalibratorHDL/LDL-Cholesterol CalibratorHomocysteine Calibrator Set, 5 levels

UIBC CalibratorVitamin D Calibrator Set, 5 levels

Supplements and Additives G6PDH Lyse Reagent, for G6PDH, UV, kinetic

Pyridoxal-5-Phosphate, for GOT and GPT, mod. IFCC

Standards Albumin StandardAmmonia StandardBile Acids StandardCalcium StandardChloride StandardCholesterol StandardCO2 StandardCopper StandardCreatinine StandardGlucose Standardβ-Hydroxybutyrate StandardIron StandardLithium Standard Set, 3 levels

Lithium Standard Set, 5 levels

Magnesium StandardNEFA StandardPhosphorus StandardPotassium Standard Set, 2 levels

Protein Total StandardProtein Total in Urine/CSF StandardSodium Standard Set, 2 levels

Triglycerides StandardUrea StandardUric Acid StandardZinc Standard

Diacon N (multi control serum, normal, human)

Diacon P (multi control serum, abnormal, human)

Diacon Lipids (lipid control serum, normal, human)

Diacon Lipids High (lipid control serum, abnormal, human)

Diacon Urine Level 1 (control urine, human)

Diacon Urine Level 2 (control urine, human)

ADA Control Set, 2 levels

Ammonia Control Set, 2 levels

Fructosamine Control N (normal)

Fructosamine Control P (abnormal)

G6PDH Control Set, 3 levels

Haemoglobin Total Control Set, 3 levels

HbA1c Control Set, 3 levels

HbA1c Direct Control Set, 2 levels

Homocysteine Control Set, 4 levels

Lithium Control Set, 2 levels

Potassium Control Set, 2 levels

Vitamin D Control Set, 2 levels

Controls

new

new

new

new

new

new

Page 6: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<IMMUNOTURBIDIMETRY Reagents

4

2 Reagent Kits (liquid) Single Reagent Kits (liquid)

BNA Reagents

α-1 Antitrypsin, antibody reagent

α-1 Acid Glycoprotein, antibody reagent

α-1 Microglobulin, latex reagent

α-2 Macroglobulin, antibody reagent

Albumin, antibody reagent

Antithrombin III, antibody reagent

APO A1, antibody reagent

APO A2, antibody reagent

APO B, antibody reagent

ASO, latex reagent

β-2 Microglobulin, latex reagent

C1 Esterase Inhibitor, antibody reagent

Complement C3, antibody reagent

Complement C4, antibody reagent

Ceruloplasmin, antibody reagent

CRP, antibody reagent

CRP HS, latex reagent

CRP Uhs, latex reagent

Cystatin C, latex reagent

D-Dimer, latex reagent

Ferritin, latex reagent

Fibrinogen, antibody reagent

Fibronectin, antibody reagent

Haptoglobin, antibody reagent

Hba1c Direct, latex reagent

IgA, antibody reagent

IgD, antibody reagent

IgE, latex reagent

IgG, antibody reagent

IgM, antibody reagent

Kappa Light Chain, antibody reagent

Lambda Light Chain, antibody reagent

Lp(a), latex reagent

Microalbumin, antibody reagent

Myoglobin, latex reagent

Prealbumin, antibody reagent

RF, antibody reagent

Transferrin, antibody reagent

α-1 Antitrypsin, antibody reagent

α-1 Acid Glycoprotein, antibody reagent

α-2 Macroglobulin, antibody reagent

Albumin, antibody reagent

APO A1, antibody reagent

APO B, antibody reagent

Complement C3, antibody reagent

Complement C4, antibody reagent

Ceruloplasmin, antibody reagent

CRP, antibody reagent

Haptoglobin, antibody reagent

IgA, antibody reagent

IgG, antibody reagent

IgM, antibody reagent

Transferrin, antibody reagent

α-1 Antitrypsinα-1 Acid Glycoproteinα-2 Macroglobulin AlbuminAPO A1APO BComplement C3Complement C4CeruloplasminHaptoglobinIgAIgGIgMTransferrin

Also available as system packs for Autolyser, BTSeries, Hitachi, Advia, Kone, Olympus, Beckman.

Page 7: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<< IMMUNOTURBIDIMETRY Calibrators & Controls

5

Calibrators (liquid) Controls (liquid)

α-1 Microglobulin CalibratorAPO A1/A2/B Calibrator* ASO Calibrator, low / high / super high

β-2 Microglobulin Calibrator, 4 level series

CRP Calibrator, low / high / super high / 5 level series

CRP HS Calibrator CRP Uhs Calibrator, universal range / high sensitive range

Cystatin C Calibrator, high / 5 level series

D-Dimer Calibrator, 5 level series*Ferritin Calibrator, 5 level series

Fibrinogen Calibrator* Fibronectin Calibrator*HbA1c Direct Calibrator, 4 level series*

IgD CalibratorIgE Calibrator, 5 level series

Lp(a) Calibrator, low / high / 4 level series

Microalbumin Calibrator, high / 5 level series

Myoglobin Calibrator, 4 level series

Pediatric CalibratorProtein Calibrator, low / high / 5 level series

(AAT, AGP, ALB, AMG, AT3, C1I, C3, C4, CER, HAP, IgA, IgG, IgM,

KAP, LAM, PAL, TRF)

RF Calibrator, low / high / super high / 5 level series

Transferrin Calibrator, 5 level series

* lyophilised

α-1 Microglobulin ControlAPO A1/A2/B Control*ASO Controlβ-2 Microglobulin ControlCRP Control, low / high

CRP HS Control CRP Uhs Control, universal range / high sensitive range

Cystatin C Control, 2 levels

D-Dimer Control, 2 levels*Ferritin Control, low / high

Fibrinogen Control*HbA1c Direct Control, 2 levels*IgE Control, 2 levels

Lp(a) Control, low / high

Microalbumin ControlMyoglobin Control, 2 levels

Pediatric ControlProtein Control, low / high

(AAT, AGP, ALB, AMG, ASO, AT3, BMG, C1I, C3, C4, CER, CRP,

FER, HAP, IgA, IgG, IgM, KAP, LAM, PAL, RF, TRF)

RF ControlTriple Control (ASO, CRP, RF)

Page 8: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Reagents (liquid)

THERAPEUTIC DRUG MONITORING

Calibrators

6

Carbamazepine, latex reagent

Digoxin, latex reagent

Phenobarbital, latex reagent

Phenytoin, latex reagent

Valproic Acid, latex reagent

TDM Calibrator Series, 6 level series, lyo.

ControlsTDM Control Set, 3 levels, lyo.

Calibrators/ ControlsAmphetamine (AMP) Cal./Ctrl. Set, 7 levels

Barbiturate (BAR) Cal./Ctrl. Set, 6 levels

Benzodiazepine (BZO) Cal./Ctrl. Set, 6 levels

Buprenorphine (BUP) Cal./Ctrl. Set, 8 levels

Cannabinoids (THC) Cal./Ctrl. Set, 12 levels

Cocaine (COC) Cal./Ctrl. Set, 7 levels

Cotinine (COT) Cal./Ctrl. Set, 6 levels

Ecstasy (MDMA) Cal./Ctrl. Set, 7 levels

Methadone (MTD) Cal./Ctrl. Set, 7 levels

Methamphetamine (MET) Cal./Ctrl. Set, 7 levels

Opiates (OPI) Cal./Ctrl. Set, 7 levels

Phencyclidine (PCP) Cal./Ctrl. Set, 7 levels

Propoxyphene (PPX) Cal./Ctrl. Set, 7 levels

DOA Multi-Analyte Cal./Ctrl. Set, 7 levels

Reagents Amphetamine (AMP) (urine)

Barbiturate (BAR) (urine)

Benzodiazepine (BZO) (urine)

Buprenorphine (BUP) (urine)

Cannabinoids (THC) (urine)

Cocaine (COC) (urine)

Cotinine (COT) (urine)

Ecstasy (MDMA) (urine)

Methadone (MTD) (urine)

Methamphetamine (MET) (urine)

Opiates (OPI) (urine)

Phencyclidine (PCP) (urine)

Propoxyphene (PPX) (urine)

DOA (DRUGS OF ABUSE)LIQUID

<<<

new new

new new

Page 9: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Drugs of Abuse (DOA) in Urine

Single Parameter Tests Amphetamines (AMP), Cassette/Dipstick

Barbiturate (BAR), Cassette/Dipstick

Benzodiazepine (BZO), Cassette/Dipstick

Buprenorphine (BUP), Cassette

Cannabinoids (THC), Cassette/Dipstick

Cocaine (COC), Cassette/Dipstick

Fentanyl (FYL), Cassette

Ketamine (KET), Cassette

Ecstasy (MDMA), Cassette/Dipstick

Methadone (MTD), Cassette/Dipstick

Methamphetamine (MET), Cassette/Dipstick

Morphine (MOP), Cassette/Dipstick

Opiates (OPI), Cassette

Oxycodone (OXY), Cassette

Phencyclidine (PCP), Dipstick

Propoxyphene (PPX), Cassette

Spice (K2), Cassette

Tramadol (TRA), Cassette/Dipstick

Tricyclic Antidepressants (TCA), Cassette/Dipstick

Multi Parameter Panels Multi-3 Drug Panel (BZO, COC, MOP)

Multi-3/1 Drug Panel (BUP, MOP, MTD)

Multi-4 Drug Panel (AMP, COC, MOP, THC)

Multi-5 Line Cassette (COC, MET, MOP, MTD, THC)

Multi-5 Drug Panel (COC, MET, BZO, THC, MOP)

Multi-5/3 Drug Panel (AMP, COC, MET, MOP, THC)

Multi-5/4 Drug Panel (AMP, COC, MDMA, MOP, THC)

Multi-5/6 Drug Panel (AMP, BZO, COC, MOP, THC)

Multi-6 Drug Panel (BZO, COC, MET, MOP, MTD, THC)

Multi-6/1 Drug Panel (AMP, BZO, COC, MET, MOP, THC)

Multi-6/4 Drug Panel (AMP, BUP, BZO, MET, MOP, THC)

Multi-6/6 Drug Panel (BUP, COC, MET, MOP, MTD, THC)

Multi-6/7 Drug Panel (BUP, BZO, COC, MOP, MTD, THC)

Multi-7 Drug Panel (AMP, BUP, BZO, COC, MTD, MOP, THC)

Multi-10 Drug Panel (AMP, BAR, BZO, COC, MDMA, MET, MOP, MTD, TCA, THC)

Multi-10/1 Drug Panel (AMP, BAR, BUP, BZO, COC, MDMA, MET, MOP, MTD, THC)

Multi-10/2 Drug Panel (AMP, BAR, BZO, COC, MDMA, MOP, MTD, OPI, TCA, THC)

Multi-10/3 Drug Panel (AMP, BZO, COC, MDMA, MOP, MTD, OPI, PCP, TCA, THC)

Multi-10/4 Drug Panel (AMP, BAR, BUP, BZO, COC, MDMA, MET, MTD, OPI, THC)

Multi-10/5 Drug Panel (AMP, BAR, BUP, BZO, COC, MET, MOP, MTD, TCA, THC)

Multi-10/6 Drug Panel (AMP, BAR, BZO, COC, MET, MOP, MTD, PCP, TCA, THC)

Multi-10/7 Drug Panel (AMP, BAR, BZO, COC, MET, MTD, OPI, PCP, TCA, THC)

DOA Multi-6 Cup (AMP, BZO, COC, MET, MOP, THC)

Multi-6 drug testing panel combined with cup and urine temperature control

7

DIAQUICK RAPID TESTS

CUT-OFF-VALUES

AMP 1000 ng/mLBAR 300 ng/mLBUP 10 ng/mLBZO 300 ng/mLCOC 300 ng/mLFYL 20 ng/mLKET 1000 ng/mLMDMA 500 ng/mLMET 1000 ng/mLMOP 300 ng/mL

MTD 300 ng/mLOPI 2000 ng/mLOXY 100 ng/mLPCP 25 ng/mLPPX 300 ng/mLSpice 30 ng/mLTCA 1000 ng/mLTHC 50 ng/mLTRA 100 ng/mL

Page 10: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Tumour MarkersAFP Cassette (serum/plasma/whole blood)

CEA Cassette (serum/plasma/whole blood)

FOB Cassette (stool samples)

FOB-TRF Combi Cassette (stool samples)

PSA Cassette (serum/plasma)

Urine Adulteration Drug Adulteration Strip, colorimetric test

DOA SalivaAlcohol Saliva Strip

DOA Saliva Multi-6 Test (AMP, COC, MET, OPI, PCP, THC)

DOA Saliva Multi-6/1 Test (AMP, COC, MET, OPI, MTD, THC)

both also available as High Sensitivity Touch Test

DOA Saliva Twist Test (AMP, COC, MET, MTD, OPI, THC)

Pregnancy / Fertility hCG Dipstick (urine)

hCG Combo Dipstick (urine/serum)

hCG Cassette (urine)

hCG Combo Cassette (urine/serum)

hCG Midstream Test (urine)

LH Dipstick (urine)

LH Cassette (urine)

Cardiac Markers Cardiac Combo Cassette (serum/plasma/whole blood)

Troponin I Cassette (serum/plasma/whole blood)

OthersCRP Dipstick (whole blood)

D-Dimer Cassette (plasma/whole blood)

Microalbumin Dipstick (urine)

DIAQUICK RAPID TESTS

8

Tests for Home Use

Pregnancy Test - Dipstick (urine)

Pregnancy Test - Midstream (urine)

Fertility Test - Dipstick (urine)

Fertility Test - Cassette (urine)

Fertility Test - Midstream (urine)

Page 11: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

9

DIAQUICK RAPID TESTS

Aids, HepatitisHAV IgM Cassette (serum/plasma/whole blood)

HBsAb Cassette (serum/plasma)

HBsAb Dipstick (serum/plasma)

HBsAg Cassette (serum/plasma)

HBsAg Cassette (serum/plasma/whole blood)

HBsAg Dipstick (serum/plasma)

HCV Cassette (serum/plasma)

HCV Cassette (serum/plasma/whole blood)

HIV Cassette (serum/plasma)

HIV Cassette (serum/plasma/whole blood)

HIV Triline Cassette (serum/plasma/whole blood)

Other Infectious DiseasesChlamydia Cassette (endocervical/urethral/urine samples)

Dengue IgG/IgM Ab Cassette (serum/plasma/whole blood)

H.pylori Cassette (serum/plasma/whole blood)

H.pylori Stool Cassette (stool samples)

Influenza Ag Dipstick (nasal/throat swab samples)

Malaria P.f. Cassette (whole blood)

Malaria P.f./Pan Cassette (whole blood) Malaria P.f./P.v. Cassette (whole blood)

Mononucleosis Cassette (serum/plasma/whole blood)

Mycoplasma IgM Cassette (serum/whole blood)

Adenovirus Cassette (stool samples)

Rotavirus Cassette (stool samples) Rota/Adeno Combi Cassette (stool samples)

S.typhi IgG/IgM Ab Cassette (serum/plasma/whole blood)

S.typhi Ag Cassette (stool/serum/plasma/whole blood)

S.typhi/paratyphi Ag Cassette (stool/serum/plasma/whole blood)

Strep.A Cassette (throat swab samples)

Strep.A Dipstick (throat swab samples)

Syphilis Cassette (serum/plasma/whole blood)

Syphilis Dipstick (serum/plasma/whole blood)

new

ToRCHToxoplasma IgG/IgM Cassette (serum/plasma)

Rubella IgM Cassette (serum/plasma)

CMV IgM Cassette (serum/plasma)

HSV 1/2 IgM Cassette (serum/plasma)

ToRCH IgM Combo Cassette (serum/plasma)

Page 12: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Latex- and HaemagglutinationASO, slide agglutination

CRP, slide agglutination

hCG direct, slide agglutination

IM, slide agglutination

RF, slide agglutination

SLE, slide agglutination

Toxoplasma gondii, slide agglutination*Waaler Rose, slide agglutination

* no

Bacterial Agglutination Brucella abortusBrucella melitensis

Proteus OX19 (P.vulgaris)

Proteus OX2 (P.vulgaris)

Proteus OXK (P.mirabilis)

Rose Bengal, slide agglutination

Salmonella paratyphi AHSalmonella paratyphi AOSalmonella paratyphi BHSalmonella paratyphi BOSalmonella paratyphi CHSalmonella paratyphi COSalmonella typhi HSalmonella typhi OSalmonella total Kit (Para AH, AO, BH, BO, CH, CO,

Typhoid H, O)

Salmonella total Kit (Para AH, AO, BH, BO, CH, CO,

Typhoid H, O, Polyvalent Pos. & Neg. Control)

Polyvalent Negative ControlPolyvalent Positive Control

Syphilis TestsSyphilis RPR, slide agglutination

Syphilis TPHA, microplate agglutination

Syphilis VDRL, glass slide agglutination

SEROLOGY

10

new

Page 13: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

11

ELISA TESTS

Aids, Hepatitis

ToRCH

HAV IgG, cut-off

HAV IgM, cut-off

HBeAb, cut-off

HBeAg, cut-off

HBsAb, cut-off

HBsAb, quantitative

HBsAg, cut-off

HBsAg Sensitive, cut-off

HCV Ab, cut-off HCV Ab Sensitive cut-off

HEV IgM, cut-off

HIV 1+2 Ab, cut-off HIV 1+2 Ag/Ab, cut-off

HTLV 1+2, cut-off

CMV IgG, quantitative

CMV IgM, cut-off

HSV 1 IgG, cut-off HSV 1 IgM, cut-off HSV 1+2 IgG, cut-off HSV 1+2 IgM, cut-off HSV 2 IgG, cut-off HSV 2 IgM, cut-off

Rubella IgG, quantitative Rubella IgM, cut-off

Toxoplasma IgG, quantitative

Toxoplasma IgM, cut-off

Other Infectious DiseasesBrucella IgA, cut-off *Brucella IgG, cut-off *Brucella IgM, cut-off *Chlamydia trachomatis IgA, cut-off * Chlamydia trachomatis IgG, cut-off * Chlamydia trachomatis IgM, cut-off *

EBV IgA, cut-off *EBV IgG, cut-off *EBV IgM, cut-off *

H.pylori Ag, quantitative H.pylori IgA, cut-off * H.pylori IgG, quantitative

Measles IgA, cut-off *Measles IgG, cut-off *Measles IgM, cut-off *

Mumps IgA, cut-off *Mumps IgG, cut-off *Mumps IgM, cut-off *

VZV IgA, cut-off *VZV IgG, cut-off * VZV IgM, cut-off *

Dengue IgG, cut-off

Dengue IgM, cut-off

Chagas IgG, cut-off

Mycoplasma pneumoniae IgA, cut-off *Mycoplasma pneumoniae IgG, cut-off *Mycoplasma pneumoniae IgM, cut-off *

RSV IgA, cut-off *RSV IgG, cut-off *RSV IgM, cut-off *

Anti-Syphilis Ab, cut-off

*quantitative detection upon request

HBcAb, cut-off

HBcIgM, cut-off

new

new

Page 14: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Autoimmune Diseases AMA-M2 IgG, quantitative

ANA Combi 8, cut-off

ANA Detect, cut-off

ANA Screen 8, cut-off

ANA-9-Line Immunoblot 08/16, semi-quantitative

ANCA Anti-BPI, quantitative

ANCA Anti-Cathepsin G, quantitative

ANCA Anti-Elastase, quantitative

ANCA Anti-Lactoferrin, quantitative

ANCA Anti-Lysozyme, quantitative

ANCA Anti-MPO, quantitative

ANCA Anti-PR3, quantitative

ANCA Combi, cut-off

Anti-Annexin V IgG/IgM, quantitative

Anti-β-2-Glycoprotein I IgA, quantitative

Anti-β-2-Glycoprotein I Screen, quantitative

Anti-β-2-Glycoprotein I IgG/IgM, quantitative

Anti-Cardiolipin IgA, quantitative

Anti-Cardiolipin IgG/IgM, quantitative

Anti-Cardiolipin Screen, quantitative

Anti-CRA, quantitative

Anti-DGP IgA, quantitative

Anti-DGP IgG, quantitative

Anti-dsDNA IgA, quantitative

Anti-dsDNA IgG, quantitative

Anti-dsDNA IgM, quantitative

Anti-dsDNA Screen, quantitative

Anti-GBM IgG, quantitative

Anti-Gliadin IgA, quantitative

Anti-Gliadin IgG, quantitative

Anti-Insulin, quantitative

Anti-Intrinsic Factor, quantitative

Anti-Phosphatidylinositol IgG/IgM, quantitative

Anti-Phosphatidylserine IgG/IgM, quantitative

Anti-Phosphatidic Acid IgG/IgM, quantitative

Anti-Phospholipid Screen IgG/IgM, quantitative

Anti-RIB-P IgG, quantitative

Anti-RNP70 IgG, quantitative

Anti-ssDNA IgG, quantitative

ASCA IgA/IgG, quantitative

ENA Anti-Jo-1 Ab, quantitative

ENA Anti-RNP/Sm Ab, quantitative

ENA Anti-Scl-70 Ab, quantitative

ENA Anti-Sm Ab, quantitative

ENA Anti-SS-A (Ro) 52 kDa, quantitative

ENA Anti-SS-A (Ro) 52/60 kDa, quantitative

ENA Anti-SS-A (Ro) 60 kDa, quantitative

ENA Anti-SS-B (La), quantitative

ENA-6 Combi, quantitative

ENA-6 Profile, semi-quantitative

ENA-6 Screen, cut-off

Gastro-5-Line Immunoblot 16, semi-quantitative

Nucleo-9-Line Immunoblot 08/16, semi-quantitative

Rheumatoid Factor IgA, quantitative

Rheumatoid Factor IgG, quantitative

Rheumatoid Factor IgM, quantitative

Rheumatoid Factor Screen, quantitative

12

ELISA TESTS

Page 15: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

13

ELISA TESTS

Thyroid Anti-TG IgG, quantitative

Anti-TPO IgG, quantitative

FT3, quantitative

FT4, quantitative

T3, quantitative

T4, quantitative

Thyroglobulin, quantitative

TSH, quantitative

Steroids 17-α-OH-Progesterone, quantitative

17-β-Estradiol, quantitative

Androstenedione, quantitative

Cortisol, quantitative

DHEA-S, quantitative

Free Estriol, quantitative

Free Testosterone, quantitative

Progesterone, quantitative

Testosterone, quantitative

Total 25-OH Vitamin D, quantitative

Total Estriol, quantitative

Fertilityβ-hCG, quantitative

FSH, quantitative

LH, quantitative

Prolactin, quantitative

Tumour MarkersAFP, quantitative

CEA, quantitative

Ferritin, quantitative

PSA, quantitative

Page 16: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

ABO and Rhesus TypingAnti-A, monoclonal

Anti-A1 Lectin*Anti-B, monoclonal

Anti-AB, monoclonal

Anti-D (IgM/IgG), monoclonal

Anti-C,D,E, monoclonal*Anti-C, monoclonal

Anti-E, monoclonal

Anti-c, monoclonal

Anti-e, monoclonal

Anti-Cw, monoclonal

Anti-C3d, monoclonal

Anti-HG, polyspecific (anti-IgG), monoclonal (anti-C3d)

BSA 22%BSA 30%LISS SolutionPapainPrecise Weak Anti-D, polyclonal*Anti-D Negative Control

Auxiliary Reagents

Rare Blood Grouping Reagents Anti-H LectinAnti-K, monoclonal*Anti-k, polyclonal

Anti-Kpa, polyclonal

Anti-Kpb, polyclonal

Anti-Lea, monoclonal

Anti-Leb, monoclonal

Anti-Lua, polyclonal

Anti-Lub, polyclonal

Anti-M, polyclonal

Anti-N LectinAnti-S, polyclonal

Anti-s, monoclonal

BLOOD GROUPING AND RHESUS TYPING

14

* no

Page 17: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

15

COAGULATION ANDFIBRINOLYSIS

TT (Thrombin Time) Thrombin Time (TT), lyo. human thrombin

PT (Prothrombin Time) Thromboplastin-S (ISI 1.15 – 1.3), lyo.

Thromboplastin liquid (ISI 1.2 – 1.35)

APTT (Activated Partial Thromboplastin Time) APTT-S liquid, silica activated

APTT-EA liquid, ellagic acid activated

Calcium Chloride, 0.020 M, for APTT-EA liquid

Calcium Chloride, 0.025 M, for APTT-S liquid

FIB (Fibrinogen) Fibrinogen Kit, human thrombin, coag. ref. plasma normal,

coag. control plasma abnormal, IBS, clotting assay

Human Thrombin, lyo.

IBS, diluent for fibrinogen assays

D-Dimer D-Dimer Latex Agglutination Kit, DD latex, DD ctrl. pos., DD ctrl. neg., DD buffer, test cards

D-Dimer for DIAcheck® & CoaLyser, DD latex, reaction buffer, IBS, DD cal., DD ctrl. low & high

D-Dimer Calibration Kit, DD latex, reaction buffer, IBS, cal. DD-3200, ctrl. low & high

Protein C Protein C Kit, substrate, activator, diluent, chromogenic assay

Protein S Protein S Kit, substrate, activator, diluent, deficient plasma,

calcium chloride, saline solution, clotting assay

new

new

Factor Deficient PlasmasDeficient Plasma Factor II, lyo., immunodepleted

Deficient Plasma Factor V, lyo., immunodepleted

Deficient Plasma Factor VII, lyo., immunodepleted

Deficient Plasma Factor VIII, lyo., immunodepleted

Deficient Plasma Factor IX, lyo., immunodepleted

Deficient Plasma Factor X, lyo., immunodepleted

Deficient Plasma Factor XI, lyo., immunodepleted

Deficient Plasma Factor XII, lyo., immunodepleted

new

Control & Reference PlasmaNormal Coagulation Control Plasma, lyo.,

for PT, APTT and FIB assays

Abnormal Coagulation Control Plasma, lyo.,

for PT, APTT and FIB assays

Normal Coagulation Reference Plasma, lyo.,

for PT and FIB assays

Special Control Plasma Normal, lyo.,

for Factor and Protein assays

Special Control Plasma Abnormal, lyo.,

for Factor and Protein assays

Special Calibration Plasma, for Factor and Protein assays

new

new

new

Page 18: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<URINE STRIPS

16

StripsUrine Strip 1GLU

Urine Strip 2GLU, KET

Urine Strip 2MCMAL, CRE

Urine Strip 3A GLU, pH, PRO

Urine Strip 4 GLU, pH, KET, PRO

Urine Strip 4SG GLU, SG, pH, PRO

Urine Strip 9 GLU, BIL, KET, SG, BLO, pH, PRO, URO, NIT

Urine Strip 10C GLU, BIL, KET, SG, BLO, pH, PRO, URO, NIT, LEU Urine Strip 11ASC, GLU, BIL, KET, SG, BLO, pH, PRO, URO, NIT, LEU

Urine ControlsUrine Comby Control Positive and negative control set for the quality control of urine strips and analysers

Strips with Mesh TechnologyUrine Strip 10MEGLU, BIL, KET, SG, BLO, pH, PRO, URO, NIT, LEU

Page 19: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

17

URINE STRIP ANALYSERS

Features• Throughput: 500 tests/h• Fast measurement cycle: 7 seconds/test• Automatic calibration of measuring unit• Large touch screen• LIS – possibility

Strip Analyser 500 / Str ip Analyser 500 ME

Interface• RS232C for barcode reader and data transfer• 25 Pin parallel port for ext. printer

General Specifications• Memory capacity of 2000 results• Barcode reader for samples and strips (closed system)• Internal thermal printer• Language: English, German, Spanish

Power Requirements,Weight and Dimensions• 100/240 VAC , 50-60 Hz• Net weight: 4.0 kg• Gross weight: 7.0 kg• 335 x 274 x 195 mm

Applicable Urine Strips• Strip Analyser 500: Urine Strip 9 Urine Strip 10C Urine Strip 11

• Strip Analyser 500 ME: Urine Strip 10 ME

Page 20: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<URINE STRIP ANALYSERS

18

Features• Throughput: Single test function: 60 tests/h Continuous test function: 120 tests/h• Automatic calibration of measuring unit• LIS – possibility

Strip Reader 40

Interface• RS232C for barcode reader and data transfer

General Specifications• Memory capacity of 2000 results• Barcode reader for samples and strips (closed system)• Internal thermal printer• Language: English, German, Spanish

Power Requirements,Weight and Dimensions• 100/240 VAC , 50-60 Hz• Net weight: 2.6 kg• Gross weight: 4.5 kg• 272 x 269 x 146 mm

Applicable Urine Strips• Urine Strip 9• Urine Strip 10C• Urine Strip 11

Page 21: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

19

General Specifications• Optic cell: Photometer with pulsed 405 nm LEDs• Sample: Plasma• Results in: Secs., INR, %, ratio, units (mg/dL, g/L, ng/mL)• Incubation block: 1 measuring and 6 sample positions, 2 reagent positions• Incubation temperature: 37.0°C ±0.2°C• LC-Display: 2 lines x 16 characters• Language: English, others on request

DIAcheck® C1 Semiautomatic 1-Channel Coagulation Analyser

Features• Clotting, chromogenic and immuno- turbidimetric assays• Low reaction volume: ¼ of regular volume (e.g. PT: 25 μL sample + 50 μL reagent)• Up to 3 calibration points• LIS – communication possible• Autostart• Maintenance free

Interface• Unidirectional RS232• Printer: External thermal printer optional

Power Requirements,Weight and Dimensions• Input: 100-240 VAC , 50-60 Hz, Output: 12 VDC , 1.0 A• Netto weight 0.51 kg; Gross weight: 1.6 kg• 245 x 130 x 65 mm

Applicable Methods• PT • APTT • TT• FIB • FAC • D-Dimer

COAGULOMETERS

Page 22: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

DIAcheck® C2 Semiautomatic 2-Channel Coagulation Analyser

Features• Clotting, chromogenic and immuno- turbidimetric assays• Low reaction volume: ¼ of regular volume (e.g. PT: 25 μL sample + 50 μL reagent)• Up to 5 calibration points• LIS – communication possible• Autostart • Maintenance free

Interface• Unidirectional RS232 • Printer: External thermal printer optional• Barcode reader optional

Applicable Methods• STAT • AT • PLG• PT • FVII • DD• APTT • FVIII • vWF• TT • FIX • ECAH• FIB • FX • ECAT• VT • FXI • a2AP• PC • FXII • LA-S• PS • FXV • LA-C• FII • HEP • FV • APCR

General Specifications• Optic cell: Photometer with pulsed 405 nm LEDs• Sample: Plasma• Results in: Secs., INR, %, ratio, units (mg/dL, g/L, ng/mL)• Incubation block: 1 x 2 measuring and 6 x 2 sample positions (double cuvettes), 3 reagent positions • Incubation temperature: 37.0°C ±0.2°C• LC-Display: 4 lines x 20 characters• Languages: English, German, French, Spanish, Italian, Portuguese

Power Requirements,Weight and Dimensions• Input: 100-240 VAC , 50-60 Hz; Output: 15 VDC , 2.0 A• Net weight: 2.0 kg; Gross weight: 3.5 kg• 230 x 200 x 120 mm

www.dialab.at

COAGULOMETERS <<<

20

Page 23: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<< COAGULOMETERS

General Specifications• Optic cell: Photometer with pulsed 405 nm LEDs• Sample: Plasma• Results in: Secs., INR, %, ratio, units (mg/dL, g/L, ng/mL)• Incubation block: 2 x 2 measuring and 12 x 2 sample positions (double cuvettes), 3 reagent positions • Incubation temperature: 37.0°C ±0.2°C• LC-Display: 4 lines x 20 characters• Languages: English, German, French, Spanish, Italian, Portuguese

DIAcheck® C4

Semiautomatic 4-Channel Coagulation Analyser

Features• Clotting, chromogenic and immuno- turbidimetric assays• Low reaction volume: ¼ of regular volume (e.g. PT: 25 μL sample + 50 μL reagent)• Up to 5 calibration points• LIS – communication possible• Autostart • Maintenance free

Applicable Methods• STAT • AT • PLG• PT • FVII • DD• APTT • FVIII • vWF• TT • FIX • ECAH• FIB • FX • ECAT• VT • FXI • a2AP• PC • FXII • LA-S• PS • FXV • LA-C• FII • HEP • FV • APCR

Interface• Unidirectional RS232 • Printer: External thermal printer optional• Barcode reader optional

Power Requirements,Weight and Dimensions• Input: 100-240 VAC , 50-60 Hz; Output: 15 VDC , 2.0 A• Net weight: 2.3 kg; Gross weight: 3.8 kg• 230 x 280 x 120 mm

21

Page 24: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

COAGULOMETERS <<<

General Specifications• Optic cell: Opto-mechanical with magnetic stir bar for homogenizing of the test suspension and increased sensitivity• Sample: Plasma• Results in: Secs., INR, %, ratio, units (mg/dL, g/L)• Incubation block: 16 samples, 4 measuring (w. light protection) and 4 reagent (1 incl. stirring) positions • Incubation temperature: 37.4°C ±0.3°C• LC-Display: 2 lines x 20 characters• Languages: English, German

DIAcheck® CP4 Semiautomatic 4-Channel Coagulation Analyser

Features• Clotting assays• Volume: Micromethod (e.g. PT: 50 μL sample + 100 μL reagent)• Data transmission to SD card or to ext. PC• Electronic starter pipette connectable• Autostart• ChipCARDTM for Cuvette management• Internal thermal printer

Applicable Methods• PT• APTT• FIB• TT• Fa-I• Fa-E• Additional 8 positions free programmable

Interface• 16-pin Mini DIN RS 232• 1USB Type B• 1SD - card slot• 1ChipCARDTM slot

Power Requirements,Weight and Dimensions• Input: 115/240 VAC , 50-60 Hz, 80 Watt• Net weight: 3.9 kg; Gross weight: 6.0 kg• 348 x 273 x 125 mm

22

Page 25: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<< COAGULATION ANALYSER

General Specifications• Throughput: PT 137/h, APTT 60/h, ± 20 tests/h• Measuring principle: Photometric with magnetic stirrer• Wavelengths: 405 / 570 / 740 nm• Sample: Plasma• Disposable cuvette ring with 32 cuvettes• 22 sample positions• 3 STAT positions• 15 reagent positions• 8 calibrator & control positions• 2 wash-solution positions• Pipettor wash station• Up to 7 calibration points, two calibration curves for each test or automatic calibration• 50 methods programmable• Temperature controlled: 37.0°C ±0.4°C• Languages: English, German

CoaLyser

Features• Clotting, chromogenic and immuno- turbidimetric assays• Volume: Micromethod (e.g. PT: 50 μL sample + 100 μL reagent)• STAT program• QC – program• Bidirectional LIS• Continuous sample loading • Internal barcode reader• Color touch screen (17,0 x 12,5 cm)• ChipCARDTM for Cuvette management

Applicable Methods• PT • Ecarin • APTT • Factors (II-XII) • FIB • PiCT • Factor V Leiden • PT/FIB • TT • D-Dimer • BT • AT III • Protein C&S • TDT

Interface• 1 x USB for ext. printer, 1 x USB for USB memory• 1 x LAN for Service• 2 x RS232C • 1x ChipCARDTM slot

Power Requirements,Weight and Dimensions• Input: 100-240 VAC , 50-60 Hz, 300 Watt• Net weight: 25 kg; Gross weight: 30 kg• 780 x 580 x 500 mm

23

Upgraded Version

Page 26: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<PHOTOMETERS

Photometer DTN-405 Features• Easy keypad operation with LCD screen• Flow-cell or cuvette mode• Internal thermal printer• Test modes: Single and double wavelength• Temperature control: RT, 25°C, 30°C, 37°C ±0.1°C• Language: English or Spanish

Analysis Modes• Endpoint with or without reagent blank or sample blank• Bichromatic endpoint (double wavelength)• Kinetic• Fixed time (two point kinetic)• Linear regression• Absorbance• Multi-calibration curve

Optical System• Wavelengths: 300 – 800 nm• 5 standard filters: 340, 405, 505, 546, 578 nm• 3 free positions for optional filters • Absorbance range: -0.500 – 3.500 Abs• Resolution: 0.001 Abs displayed; 0.0001 calculated• Light source: Tungsten Halogen lamp

Interface• RS232 bidirectional communication• SPP (Standard Parallel Port) for external printer

Power Requirements,Weight and Dimensions• 110/230 VAC , 50/60 Hz, 80 Watt• Net weight: 7 kg, Gross weight: 8.5 kg• 360 x 318 x 160 mm

Data Management• Test memory: up to 60 methods programmable, 1000 test results• QC functions: Control report

24

Page 27: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Photometer DTN-510K

PHOTOMETERS

Features• Color LCD screen• Flow-cell or cuvette mode• Internal thermal printer• Test modes: Single and double wavelength• Temperature control: RT, 25°C, 30°C, 37°C ±0.1°C• Language: English or Spanish• Real-time-reaction curve display• Equipped with USB mouse and built-in keyboard• Windows® based operating system

Optical System• Wavelengths: 300 – 800 nm• 7 standard filters: 340, 405, 450, 500, 546, 578, 670 nm• 1 free position for optional filter • Absorbance range: -0.500 – 3.500 Abs• Resolution: 0.001 Abs displayed; 0.0001 calculated• Light source: Tungsten Halogen lamp

Analysis Modes• Endpoint with or without reagent blank or sample blank• Bichromatic endpoint (double wavelength)• Kinetic• Fixed time (two point kinetic)• Linear regression• Absorbance• Multi-calibration curve

Data Management• Test memory: up to 110 methods programmable, 1000 test results• QC functions: Westgard Multirule, Levey Jennings plot, 2 controls per test Interface• RS232 for LIS• 2x USB: Mouse and ext. keyboard or ext. printer (not included)

Power Requirements,Weight and Dimensions• 110/230 VAC , 50/60 Hz, 80 Watt• Net weight: 8 kg, Gross weight: 9.5 kg• 350 x 330 x 165 mm

25

Page 28: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

Autolyser

www.dialab.at

<<<

Power Requirements,Weight and Dimensions• 100 / 240 VAC , 50-60 Hz, 300 Watt• U.P.S: 1500 Watt• Net weight: 53 kg, Gross weight: 88 kg• 510 x 780 x 580 mm

CLINICAL CHEMISTRY ANALYSERS

26

Water Consumption• Approximately 5ml / test

Interface• USB Port

• Throughput up to 250 tests/hour• Operating mode: Random access• Test modes: Routine, Batch, STAT, Profiles• Up to 500 tests in memory• Sample / calibrator pre-dilution• Cooled reagent tray• Cuvette washing station• Solid state photometer with 10 channels 340 - 700 nm• Long life ceramic dilutor• QC program• Patient archive• Operating by external PC (not included) • Non disposable optical glass cuvettes• Optional barcode reader for samples and reagents• Liquid tanks for system water and waste water• Bidirectional LIS• Systempacks available

General Features

New Design

Page 29: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

27

CLINICAL CHEMISTRY ANALYSERS

Reagents / Samples / Cuvettes

• Reagent tray: 48 positions, cooled• Sample tray: 78 positions total (62 routine & STAT, 16 control & calibrator)• Reaction tray: 32 glass cuvettes, heated• Sample volume: 1.8 to 100 μL• Reaction volume: 180 to 400 μL• Cuvette temperature: OFF, 30, 32, 37°C ± 0.2°C (Peltier controlled)

Photometer• Solid state photometer 10 channels + 1 ref. channel• Wavelengths: 340, 380, 405, 436, 480, 510, 546, 578, 630, 700 nm• Absorbance range: 0.000 – 3.000 Abs• Sensitivity: ± 0.001 Abs• Accuracy: ± 1% from 0 to 2.000 O.D• Tungsten halogen lamp with dichroic reflector• Lamp Life time approximately 2000 hours

Pipetting Arm / Dilutor • 1x Pipetting arm for reagents and samples• 1x Long life ceramic dilutor • Dilutor precision: ± 0.1 %• Dilutor resolution: ± 0.1 μL

Analysis Modes• End Point (with / without sample or reagent blank)• Fixed Time• Kinetics• Read only

Calibration Modes• With factor • Best fit• Linear • Multi points• With curve • Log-logit 4• Cubic spline • Log-logit 5• Polynomial • Semi-log

Page 30: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

Autolyser 450

CLINICAL CHEMISTRY ANALYSERS

28

• Throughput up to 450 tests/h without I.S.E up to 690 tests/h with I.S.E • Optional with I.S.E module (Na, K, Cl, Li)• Operating mode: Sequential access• Test modes: Routine, Batch, STAT, Profiles• Up to 500 tests in memory• Sample / calibrator pre-dilution• Cooled reagent tray• Cooled calibrator & control tray• Cuvette washing station• Solid state photometer with 14 channels 340 - 800 nm• Long life ceramic dilutors• Clot sensor• Crash sensor• QC program• Patient archive• Operating by external PC (PC not included) • Non disposable optical glass cuvettes• Internal barcode reader for samples and reagents• Bidirectional LIS• Liquid tanks for system water and waste water• Systempacks available

General Features

Power Requirements,Weight and Dimensions• 100 / 240 VAC , 50-60 Hz, 1000 Watt• U.P.S: 1500 Watt• Net weight: 162 kg, Gross weight: 237 kg• 1150 x 1150 x 720 mm

Water Consumption• 9.5 ml / test

Interface• USB port

Page 31: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

29

CLINICAL CHEMISTRY ANALYSERS

Reagents / Samples / Calibrators & Controls / Cuvettes• Reagent tray: 80 positions, cooled• Sample tray: 100 positions • Calibrator & control tray: 26 positions, cooled• Reaction tray: 84 glass cuvettes (6 mm), heated• Sample volume: 1.5 μL to 100 μL• Reaction volume: 180 μL to 400 μL• Cuvette temperature: OFF, 30, 32, 37°C ± 0.2°C (Peltier controlled)

Analysis Modes• End Point (with / without sample or reagent blank)• Fixed Time• Kinetics• Read only

Pipetting Arms / Dilutors• 1x Sample pipetting arm 2x Reagents pipetting arms• 3x Long life ceramic dilutors• Dilutor precision ± 0.1 %• Dilutor resolution ± 0.1 μL for serum ± 1.0 μL for reagents

Photometer• Solid state photometer 14 channels • Wavelengths: 340, 380, 405, 436, 478, 510, 546, 578, 600, 630, 660, 700, 740, 800• Absorbance range: 0.000 – 3.000 Abs• Sensitivity: ± 0.001 Abs• Accuracy: ± 1% from 0 to 2.000 O.D• Tungsten halogen lamp with dichroic reflector• Lamp life time approximately 2000 hours

Calibration Modes• With factor • Best fit• Linear • Multi points• With curve • Log-logit 4• Cubic spline • Log-logit 5• Polynomial • Semi-log

Page 32: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

30

• 1 reading channel with measuring range from 400 nm to 750 nm • Microplates: 6-, 12-, 24-, 48-, or 96-well

DIAREADER ELx800G

• 1 reading channel with extended measuring range from 340 nm to 750 nm • Microplates: 6-, 12-, 24-, 48-, or 96-well

DIAREADER ELx800 UV

• 1 Reading channel with measuring range from 400 nm to 750 nm • Microplates: 384-well plates and 60-, 72-, 96- well Terasaki plates as well as 6-, 12-, 24-, 48-, or 96-well plates

DIAREADER ELx800 NB

DIAREADER ELx808IU* • 8 reading channels with a 4-ZoneTM incubation chamber and UV capability• Measuring range from 340 nm to 900 nm • Microplates: 96-well plates* Please note: different general and technical specifications. Different weight and dimensions. For more information please refer to seperate brochure.

General Specifications

• Detection mode: Absorbance• Endpoint, Kinetic • 5 positions filter wheel• Standard filters: 405, 450, 490, 630 nm “UV” model includes a 340 nm filter• Absorbance range: 0.000-3.000 Abs• Resolution: 0.001 Abs• Accuracy: ±1% ±0.0010 Abs from 0.000 to 2.000 Abs• Linearity: ±1% from 0.000 to 2.000 Abs, ±3% from 2.000 to 3.000 Abs

Interface• 1x RS232 serial COM port• 1x USB port• 1x Parallel port

Power Requirements,Weight and Dimensions

• Input: 100-240 VAC , 50-60 Hz • Net weight: 8.4 kg, Gross weight: 11.5 kg• 419 x 381 x 178 mm

All models are equipped with GEN 5 ELISA Software for easy operating using an external computer

www.dialab.at

<<<ELISA READER

Page 33: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

31

www.dialab.at

<<< ELISA WASHER

General Specifications• 96-well washing: 8-tube (1x8) manifold (standard)• 96-/384-well washing: 12-tube (1x12) manifold (optional) Dual-Action™ 16-tube (1x16) manifold (optional)• Washing speed: < 130 seconds• Volume range: 25 – 3000 μL / well • Wash cycles: 1 – 10• Residual volume: < 2 μL / well• Dispense precision: < 3% CV• Soak time: Up to 60 minutes• Shaking: Up to 60 minutes • Shaking intensities: Slow, medium, fast or variable

DIAWASHER II ELx50

Features• For washing single strips or full plates• Microplate types: flat, round or V-shaped wells• 96- and 384-well microplates• Wash, prime, rinse and aspiration programs• Up to 75 washer programs storable• Bottom washing• Shaker: Programmable shaking duration and intensity• Over-flow protection• Built-in maintenance programs• Aerosol cover for safety

Power Requirements,Weight and Dimensions• Input: 100-240 VAC , 50-60 Hz• Net weight: 9,8 kg; Gross weight: 12,5 kg• 356 x 406 x 165 mm

Page 34: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

32

AUTOMATED ELISA SYSTEMS

General SpecificationsNumber of plates: 2Number of assays: 1 assay per strip or up to 12 assays/plateNumber of sample tubes: 100Number of reagents: 18Number of standard/control bottles: 24Number of pipettes: 1Clot detection: Yes

System Modules• Reader• Washer• Incubator• Sample module• Ambient drawer • Barcode reader (optional)• Liquid tanks for system water and waste water

DIALISA 2MP

Features

• Fully-automated two plate ELISA operating system• Smallest footprint on the market for a fully automated 8 pin wash head ELISA system• Rapid pipetting speed minimizes assay drift, ensuring consistent results across the plate and plate-to-plate• Learned error recovery: Supporting walk-away automation with trained error recovery actions• LIS and LMS compatible• QC monitoring • Sample identification with an on-board barcode reader (optional)• Disposable tips eliminating carryovers• Compatible with DIALAB ELISA assays

Page 35: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

33

AUTOMATED ELISA SYSTEMS

Sample PipettingSample tip size: 300 μLSample pipetting volume: 10 – 250 μLPrecision: ≤ 3% CV Dilution range: 1 to 5000Replicates: Up to 96 samples, standards and controlsNumber of sample-tips: 2 racks of 108Sample tube dimensions: 10 – 16 mm Ø 40 – 100 mm depth

Reagent PipettingReagent tip size: 1300 μLNumber of reagent tips: 20Reagent pipetting volume: 20 – 1000 μLReagent pipetting precision: ≤ 3% CV

Washer SpecificationsManifold configuration: 8 – way Programmable volumes: 50 – 1000 μLWash containers: 2 wash bottles at 2.0 L, with level-sensingWaste containers: 1.5 L with waste-full sensorResidual wash volume: < 3 μL

Incubator SpecificationsNumber of incubators: 1Temperature range: RT, 4° C to 40° CTemperature accuracy: ± 1° CShaking: 14-20 Hz periodic or continuous

Reader SpecificationsPhotometric range: 0.000 – 3.000 ODSpectral range: 405 nm – 690 nmFilters installed: 405, 450, 490, 620 nmPrecision: < 1% CV (< 2.000 OD) < 2% CV (2.000 – 3.000 OD)Accuracy: 0.005 OD or 2.5% Reading time: < 30 sec., single wavelength

Voltage: 100 – 240 VAC, 50/60 HzPower consumption: < 300 VA, UPS recommendedNet weight: 45 kgGross weight: 80 kgDimensions: (W x D x H) Device: 45 x 68 x 66 cmShipping box: 102 x 71 x 100 cm

Power Requirements, Weight and Dimensions

Sample tips (4x 108 tips)Reagent tips (1x 108 tips)Deep well strips 8-well (Pack of 12)Reagent tubes, 25 mL (Pack of 10)Reagent tubes, 15 mL (Pack of 10)Control vials (Pack of 33)

Starter Kit

Page 36: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

34

DIALISA 4MP

Features

General SpecificationsNumber of plates: 4Number of assays: 1 assay per strip or up to 12 assays/plateNumber of sample tubes: 96Number of reagents: 24Number of standard/control bottles: 33Number of pipettes: 1Clot detection: No

System Modules• Reader• Washer• Incubators (up to four)• Sample module• Ambient drawer (Room temperature)• Barcode reader (optional)• Liquid tanks for system water and waste water

• Fully-automated four plate ELISA operating system• Modular system: Quick and easy approach for upgrades, repairs and reconfiguration of the whole system• Rapid pipetting speed minimizes assay drift, ensuring consistent results across the plate and plate-to-plate• Learned error recovery: Supporting walk-away automation with trained error recovery actions• Automatic cover lock protecting reagents and samples from light and interferences• LIS and LIMS compatibility• QC monitoring• Sample identification with an on-board barcode reader• Disposable tips eliminating carryovers• Compatible with DIALAB ELISA Assays

AUTOMATED ELISA SYSTEMS

Page 37: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<

35

AUTOMATED ELISA SYSTEMS

Sample PipettingSample tip size: 300 μLSample pipetting volume: 5 – 250 μLPrecision: ≤ 3% CV Dilution range: 1 in 190 one-stage dilution, 1 in 36100 two-stage dilutionNumber of sample-tips: 4 racks of 108Sample tube dimensions: 12 – 16 mm Ø 55 – 100 mm depth

Reagent PipettingReagent tip size: 1300 μLNumber of reagent tips: 41Reagent pipetting volume: 35 – 1000 μLReagent pipetting precision: ≤ 3% CV

Washer SpecificationsManifold configuration: 8 – way Programmable volumes: 50 – 999 μLWash containers: 4 wash bottles at 2.0 L, with level-sensingWaste containers: 8 L with waste-full sensorResidual wash volume: < 3 μL

Incubator SpecificationsNumber of incubators: 4Temperature range: RT, 7° C to 50° CTemperature accuracy: ± 1° CShaking: 15 Hz periodic or continuous

Reader SpecificationsPhotometric range: 0.000 – 3.000 ODSpectral range: 405 nm – 690 nmFilters installed: 405, 450, 490, 620 nmPrecision: ± 0.01 OD ( < 0.500 OD) < 1% CV (0.501 – 2.000 OD) < 1.5% CV (2.001 – 2.500 OD)Accuracy: ± 0.01 OD or 2.5% Reading time: < 10 sec., single wavelength < 20 sec., dual wavelength

Voltage: 100 – 240 VAC, 50/60 HzPower consumption: 800 VA, UPS recommendedNet weight: 136 kgGross weight: 244 kgDimensions: (W x D x H) Device: 106 x 91 x 80 cmShipping box: 123 x 110 x 109 cm

Power Requirements, Weight and Dimensions

Sample tips (4x 108 tips)Reagent tips (4x 108 tips)Deep well strips 8-well (Pack of 24)1ml Deep well microplate (2 Pcs)Reagent tubes, 25 mL (Pack of 24)Control vials (Pack of 33)

Starter Kit

Page 38: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<<BLOOD GLUCOSE &HEMOGLOBIN TESTING

DiaCheck® Pro Blood Glucose Monitoring System

Specifications• Methodology: Electrochemistry• Calibration: Plasma equivalent• Coding: Code free• Sample material: Capillary and venous whole blood• Test range: 10 – 900 mg/dL (0.6 – 50 mmol/L)• Hematocrit range: 20 – 60 %• Test time: 5 seconds• Sample volume: 0.5 µL• Memory: 1000 test results with date and time• In compliance with: EN ISO 15197:2013

Test Strips and Controls• 2 x 25 Blood Glucose Test Strips• 2 x 4 mL Glucose Control Solution

Specifications

• Methodology: Electrochemistry• Coding: Code key• Sample material: Capillary and venous whole blood• Test range: 5 – 26 g/dL (3.1 – 16.1 mmol/L)• Hematocrit range: 15 – 78 % (calculated)• Test time: 5 seconds• Sample volume: 1 µL• Memory: 1000 test results with date and time

DiaCheck® Hb Hemoglobin Testing System

Test Strips and Controls• 50 Hemoglobin Test Strips• 2 x 3 mL Hemoglobin Control Solution

36

Page 39: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

www.dialab.at

<<< CERTIFIED QUALITY

2015/03

Page 40: PRODUCT RANGE 2015  · IgD, antibody reagent IgE, latex reagent IgG, antibody reagent ... Lp(a) Control, low / high Microalbumin Control Myoglobin Control, 2 levels Pediatric Control

Austria (Head Office)DIALAB® GmbH

IZ NÖ SüdHondastrasse, Objekt M55

A-2351 Wiener NeudorfPhone: +43-2236-66 09 10-0Fax: +43-2236-66 09 10-30

e-mail: [email protected]

www.dialab.at

Czech RepublicDIALAB® spol. s r.o.

Námestí Osvoboditelu 1CZ-153 00 Praha 5 - Radotín

Phone/Fax: +420-2-579 10 255e-mail: [email protected]

www.dialab.cz

Slovak RepublicALPHA DIALAB® s.r.o.

Sekurisova 16SK-84102 Bratislava

Phone: +421-917 98 3711e-mail: [email protected]

SerbiaDIALAB® d.o.o.Carigradska 1

RS-11 008 Beograd 12Phone: +381-11-32 38 745

Fax: +381-11-32 42 777e-mail: [email protected]

HungaryDIALAB® Kft.Pasaréti út 31

H-1026 BudapestPhone: +36-1-212 25 05

Fax: +36-1-335 73 70e-mail: [email protected]

www.dialab.hu

˚ˇ

DIALAB® Produkt ion und Vertr ieb von chemisch-technischen Produkten und Laborinstrumenten Gesel lschaft m.b.H.

DIALAB® reser ves the r ight to change spec i f ica t ions w i thout pr io r not ice as par t o f a cont inous product improvement .