DATA&IT, C-UPS PRODUCT PRESENTATION PROTECT D.6000 / D.10000

PRODUCT PRESENTATION PROTECT D.6000 / D · PDF file · 2016-06-07with PFC correction 6000VA / 4200W • Power extension to 10kVA. 6 ... ABLE TO COVER THE COMPLETE POWER FACTOR SPECTRUM

  • Upload
    hadien

  • View
    216

  • Download
    1

Embed Size (px)

Citation preview

DATA&IT, C-UPS

PRODUCT PRESENTATIONPROTECT D.6000 / D.10000

2

Ho

me

, S

oH

oO

ffic

e, S

oH

o,

IT s

eg

me

nt

Co

mp

act U

PS

PROTECT alpha

450 bis 1200 VA

Suitable protection for SoHo

applications, telephone

equipment, NAS systems,

PCs

PROTECT HOME

600 VA

Complete protection for

multimedia applications

PROTECT C

1000 bis 10000 VA

Tower UPS for sensitive

netzworks, intranet and

internetserver

PROTECT 1

10000 bis 20000 VA

For small data centres,

protection of cash till systems

& building facilities

PROTECT B.PRO

750 bis 3000 VA

Efficient rack / tower UPS for

small server and network

components

with sinusodial

output

PROTECT D

1000 bis 10000 VA

Compact UPS for rack

mounted protection of server,

network and IT equipment

PROTECT A

500 bis 1400 VA

Protection for PCs,

workstations and telephone

equipment

PROTECT 1.M

4000 bis 24000 VA

Scalable and modular

high performance

UPS system

for the IT

sector

PROTECT B

500 bis 1500 VA

sinusodial outputvoltage,

Surge protection for

telephone, fax, router and

network

PROTECT

ENTERTAINMENT

Intelligent protection for

entertainment equipment

with master-slave-function

Surg

e p

rote

ctio

n PROTECT

BASIC

Power strip for all

standard applications

PROTECT

TRAVEL

Security on the move for

safety charging of your

devices

PROTECT

TWINPOWER

Security for flexible

connectivity and safe

power supply

PROTECT

BUSINESS

Business solution with

surge protection and

USB-Charger

PROTECT

OFFICE

Compact protection for

PC and peripheral

equipment

AEG´S COMMERCIAL COMPACT-UPS PRODUCT PORTFOLIO

AND FIELD APPLICATION

CO

MP

AC

T-U

PS

PR

OD

UC

T P

OR

TF

OL

IO

3

CLASSIFICATION ACC. TO

UPS PRODUCT NORM IEC 62040- 3

CL

AS

SIF

ICA

TIO

N E

nerg

y E

fficie

ncy S

olu

tion

s

Voltage Phenomenon Time e.g. IEC UPS Arrester62040-3 solution solution

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Outage - blackouts

Sags / brownouts

Dynamic overvoltage

Undervoltage

Overvoltage

Transients (Surge)

Frequency variations

Voltage distortion (Burst)

Voltage harmonics

Lightning

> 10 ms

continuous

continuous

< 4 ms

sporadic

periodic

continuous

sporadic

VFD

Voltage +

Frequency

Dependent

VI

Voltage

Independent

VFI

Voltage +

Frequency

Independent

Classification 3

Offline

Classification 2

Line-Interactive

Classification 1

(true) Online

real Double-

Conversion

Surge- and Over-voltage protection(IEC 60364-5-534)

see as well 10.

Limited protection via UPS

(extended protectionrecommended (10.))

PR

OT

EC

T D

.

PRODUCT

HIGHLIGHTS

5

PERFORMANCE – MORE POWERFUL SERIES

POWER RATING AT PF=0.9LAG. FOR ALL PROTECT D. MODELS

PR

OD

UC

T H

IGH

LIG

HT

S –

PE

RF

OR

MA

NC

E

• 6000 VA/ 5400 W

• 10000 VA/ 9000 W

• more power for modern SPS loads

with PFC correction

6000 VA / 4200 W

• Power extension to 10kVA

6

PERFORMANCE – POWER BANDWIDTH

ABLE TO COVER THE COMPLETE POWER FACTOR SPECTRUM

PR

OD

UC

T H

IGH

LIG

HT

S –

PE

RF

OR

MA

NC

E

able to handle

pure lagging loadable to handle

pure leading load

00.90.8 0.90.7 0.8 0.7 0.60.60.5 0.50 0.1 0.2 0.3 0.4 00.4 0.3 0.2 0.1

leading load (pf=... cap.)lagging load (pf =... lag.)

active load (pf =1)

full power

7

PERFORMANCE – POWER BANDWITH

ABLE TO OPERATE 100% NON-LINEAR LOAD

PR

OD

UC

T H

IGH

LIG

HT

S –

PE

RF

OR

MA

NC

E

• Cleaner power

( ≥ 0.99 THDi < 5% )

Input voltage (mains)

Input current (mains)

UPS output voltage

Current (UPS load)

• Less power pollution • Suitable for all

kind of loads

EFFICIENCY

9

PERFORMANCE – EFFICIENCY

SHORT-TERM AMORTIZATION – LESS COOLING

PR

OD

UC

T H

IGH

LIG

HT

S –

PE

RF

OR

MA

NC

E

6000 VA / 4200 W

> 88%

6000 VA / 5400 W

92%

> 96% ECO

at the weekend

• Consumption at 90% load (3780W)

Losses at 8760h/year = 4515 kWh

• Consumption at 3780W

Losses = 2879 kWh

2063 kWh less losses

Saving/year: ~412 € *

1636 kWh less losses / Saving per year: ~ 327 € *

double-conversion

( VFI ) mode

* calculation basics

EUR 0.20 per kWh

10

PR

OD

UC

T H

IGH

LIG

HT

S –

FO

OT

PR

INT

6000 VA / 4200 W 6000 VA / 5400 W

3U

• only 3 U height … and manual bypass

PROTECT D.6000

incl. battery system

FOOTPRINT – LESS RACK SPACE REQUIRED

11

PR

OD

UC

T H

IGH

LIG

HT

S –

MA

INT

EN

AN

CE

INSTALLATION/ MAINTENANCE

• Removable connection unit

for easy connection and most effective maintenance procedure

• Using the manual bypass switch

automatically the load will be transferred the bypass mains

• Subsidiary distribution

for direct connection of the load, respectively other PDU´s

• Outlets with innovative lock mechanism

to avoid blackouts by removing the load cable accidentially

e.g. rear view D.6000

12

PACKAGING

PR

OD

UC

T IN

FO

PA

CK

AG

ING

• ONE package for all components

of PROTECT D.6000 / D.10000

• ONE article-no.

to simplify the logistics

• Easy handling on site

as each component provides

a weight of less than 30kg

• Safe shipment

acc. to disconnected batteries

13

PR

OD

UC

T IN

FO

UN

PA

CK

AG

ING

UNPACKAGING – E.G. PROTECT D.6000

1 2

3 4

14

PR

OD

UC

T IN

FO

SH

IPM

EN

T

SHIPMENT – PROTECT D.6000

PROTECT D.6000

Main parts

• UPS unit6000 VA / 5400 W

• Connection unitwith subsidiary distributionand integrated manual bypass

• Battery system as slide-in module

• Printed Safety and Operating Instructionsincl. installation description

Accessories (included)

• Rail slider kit incl. bracketsfor max. post distance of 1200mm

• Glands ( PG29 - 3pcs.)

• Output cable ( IEC320-C20 > IEC320-C19 )

• Communication cables ( RS232 & USB)

• Shutdown- and Management Software“CompuWatch” incl. fivefold network licence

• Registration cardfor extended warranty of 36months

15

PR

OD

UC

T IN

FO

–S

HIP

ME

NT

SHIPMENT – PROTECT D.10000

PROTECT D.10000

Main parts

• UPS unit10000 VA / 9000 W

• Connection unitwith subsidiary distributionand integrated manual bypass

• Battery system as slide-in modules ( 2pcs.)

• Printed Safety and Operating Instructionsincl. installation description

Accessories (included)

• Rail slider kit incl. bracketsfor max. post distance of 1200mm

• Glands ( PG36 - 3pcs.)

• Output cable ( IEC320-C20 > IEC320-C19 )

• Communication cables ( RS232 & USB)

• Shutdown- and Management Software“CompuWatch” incl. fivefold network licence

• Registration cardfor extended warranty of 36months

PROTECT D.10000

16

PR

OD

UC

T H

IGH

LIG

HT

S –

INS

TA

LL

AT

ION

INSTALLATION – E.G. PROTECT D.10000

Single INPUT Dual INPUT

Removable connection unit

Cable entry either

from the back or the top

(suitable for network cabinets

with a depth of 800 mm only)

17

PR

OD

UC

T IN

FO

CO

NN

EC

TIO

NS

REAR VIEW – CONNECTIONS PROTECT D.6000

2 pcs. IEC320 C13 & 1pc. IEC320 C19

with automatic locking mechanism

Maintenance Bypass

with undetachable screws

Terminals inside

Dual or Single InputRS232

Port

Fuses for

sub-distribution

USB

Port

Parallel

port

Programmable

potential-free contact

Communication slot

Emergency

Power Off

Solid screw

for direct earthing

Pre-punched holes

Glands can be installed

either on top or on back

GLN & S/N

Serial-number also

provided on the display

Intelligent

fan speed control

18

PR

OD

UC

T IN

FO

CO

NN

EC

TIO

NS

REAR VIEW – CONNECTIONS PROTECT D.10000

4 pcs.

lockable IEC320 C19

Rectifier OutputBypass

Terminals inside

USB

Port

Fuses

for each pair

of receptacles

RS232

Port

RJ11

(battery detection)

External battery

connector

Parallel

port

Programmable

potential-free contact

Communication

slot

Emergency

Power Off

Dual or Single Input

Solid screws

for direct

earthing

Pre-punched

holes

Glands can

be installed

either on top

or on back

Glands are part

of delivery

GLN & S/N

Serial-number

also provided

on the display

Maintenance Bypass

with undetachable screws

19

PR

OD

UC

T IN

FO

OP

ER

AT

ION

UPS OPERATION – LCD DISPLAY

• Display for UPS status, Control,

Settings, Measurements, Event

Log, Identification

• Real time clock

( synchronized automatically )

• Data logger for 127 events

• For more details refer to the

PROTECT D. presentation

in the range from 1 to 3 kVA

• Graphical LCD display

( 128 x 64 pixel )

• Multilingual >> 5 languages

( EN / DE / FR / ES / RU )

2.8 "

Viewing area:

59.65 x 39.02 mm

20

PR

OD

UC

T IN

FO

BA

TT

ER

Y E

XT

EN

SIO

N

EXTERNAL BATTERY PACKS

PROTECT D.6000

• Front connection

• Automatic detection

• Process

hot – swappable

• Connection

with fixed polarity

PROTECT D.10000

• Rear connection

• Automatic detection

• Process

hot – swappable

• Connection

with fixed polarity

21

PR

OD

UC

T IN

FO

AU

TO

NO

MY

DA

TA

( I )

AUTONOMY TIME DATA – PROTECT D.6000

Full load / half load

at pf = 0.9 lag. at pf = 0.7 lag.

with integrated batteries

3 / 9.5 5 / 13

with 1 additional battery pack

11 / 27 15 / 39

with 2 additional battery packs

20 / 46 26 / 67

with 3 additional battery packs

30 / 68 38 / 98

with 4 additional battery packs

40 / 91 51 / 132

3U

3U

3U

3U

3U

22

PR

OD

UC

T IN

FO

AU

TO

NO

MY

DA

TA

( II )

AUTONOMY TIME DATA – PROTECT D.10000

PROTECT D.10000BP

PROTECT D.10000BP

PROTECT D.10000BP

PROTECT D.10000BP

PROTECT D.10000

5U

3U

3U

3U

3U

Full load / half load

at pf = 0.9 lag. at pf = 0.7 lag.

with integrated batteries

4 / 7.5 5,5 / 10,5

with 1 additional battery pack

9 / 18 12 / 25

with 2 additional battery packs

15 / 30 20 / 41

with 3 additional battery packs

21 / 43 28 / 59

with 4 additional battery packs

27 / 57 36 / 78

23

PR

OD

UC

T IN

FO

AU

TO

NO

MY

DA

TA

( III )

AUTONOMY TIME DATA IN DETAIL

AT PART LOAD ( PF = 0.9 LAGGING )

PROTECT D. (Rack model)

at part load

< < < A u t o n o m y t i m e a t p f = 0.9 l a g g i n g > > >

10% load 25% load 50% load 75% load 100% load

PROTECT D.6000 [ 6 kVA ] = 540 W = 1350 W = 2700 W = 4050 W = 5400 W

with integrated battery system 65 min. 23 min. 9.5 min. 5.5 min. 3 min.

with 1 x PROTECT D.6000BP 182 min. 66 min. 27 min. 16 min. 11 min.

with 2 x PROTECT D.6000BP 315 min. 114 min. 46 min. 28 min. 20 min.

with 3 x PROTECT D.6000BP 461 min. 168 min. 68 min. 41 min. 30 min.

with 4 x PROTECT D.6000BP 616 min. 225 min. 91 min. 54 min. 40 min.

PROTECT D.10000 [ 10 kVA ] = 900 W = 2250 W = 4500 W = 6750 W = 9000 W

with integrated battery system 54 min. 17.5 min. 7.5 min. 5.5 min. 4 min.

with 1 x PROTECT D.10000BP 128 min. 41 min. 18 min. 13 min. 9 min.

with 2 x PROTECT D.10000BP 212 min. 68 min. 30 min. 21 min. 15 min.

with 3 x PROTECT D.10000BP 310 min. 97 min. 43 min. 29 min. 21 min.

with 4 x PROTECT D.10000BP 399 min. 128 min. 57 min. 38 min. 27 min.

24

PR

OD

UC

T IN

FO

AU

TO

NO

MY

DA

TA

( IV )

AUTONOMY TIME DATA IN DETAIL

AT PART LOAD ( PF = 0.7 LAGGING )

PROTECT D. (Rack model)

at part load

< < < A u t o n o m y t i m e a t p f = 0.7 l a g g i n g > > >

10% load 25% load 50% load 75% load 100% load

PROTECT D.6000 [ 6 kVA ] = 420 W = 1050 W = 2100 W = 3150 W = 4200 W

with integrated battery system 76 min. 34 min. 13 min. 8 min. 5 min.

with 1 x PROTECT D.6000BP 208 min. 91 min. 39 min. 22 min. 15 min.

with 2 x PROTECT D.6000BP 360 min. 156 min. 67 min. 39 min. 26 min.

with 3 x PROTECT D.6000BP 524 min. 226 min. 98 min. 57 min. 38 min.

with 4 x PROTECT D.6000BP 700 min. 301 min. 132 min. 77 min. 51 min.

PROTECT D.10000 [ 10 kVA ] = 700 W = 1750 W = 3500 W = 5250 W = 7000 W

with integrated battery system 74 min. 24 min. 10.5 min. 7.5 min. 5.5 min.

with 1 x PROTECT D.10000BP 175 min. 56 min. 25 min. 17 min. 12 min.

with 2 x PROTECT D.10000BP 290 min. 93 min. 41 min. 28 min. 20 min.

with 3 x PROTECT D.10000BP 413 min. 133 min. 59 min. 39 min. 28 min.

with 4 x PROTECT D.10000BP 545 min. 175 min. 78 min. 51 min. 36 min.

25

PR

OD

UC

T IN

FO

BA

TT

ER

Y R

EP

LA

CE

ME

NT

BATTERY REPLACEMENT – PROTECT D.6000

1 2

3

4

26

PR

OD

UC

T IN

FO

BA

TT

ER

Y R

EP

LA

CE

ME

NT

BATTERY REPLACEMENT – PROTECT D.10000

1 2

34

27

PARALLEL OPERATION

Parallel operation of 2 units to

• achieve active redundancy

• increase power

PR

OD

UC

T IN

FO

–P

AR

AL

LE

L O

PE

RA

TIO

N ( I )

Parallel field / external central bypass

plus UPS sub-distributor

Low voltage main distributor

( UPS (mains rectifier & bypass))

28

UPS PARALLEL FIELD ”PDB 20000” AS OPTION

PR

OD

UC

T IN

FO

–P

AR

AL

LE

L O

PE

RA

TIO

N ( II )Parallel field in 19" rackmount design

• Space requirement 3U

• Front accessible operating elements

• Foolproof manual bypass switch

by using additional UPS info

• LEDs for clear signalling

of current operating mode

• Covered control elements

to avoid mistakenly fuse operation

• Schematic circuit diagram

for quick and easy guidance

29

CO

NC

LU

SIO

N

COMPETITIVENESS – CONCLUSION

• More real power

( pf of 0.9 lagging, suitable for all kind of critical loads )

• Compact size, modern solid look with aluminium front

( incl. battery, removable sub-distribution and manual bypass )

• Easiest and most flexible installation

acc. to mounting (especially weight) and electrical installation

• Opportunity to feed the UPS by separate inputs

( DUAL or SINGLE input )

• Prepared for parallel operation

to achieve active redundancy or higher output power

• Further on most highlights of the smaller PROTECT D. products

( refer to the separate presentation of PROTECT D. 1 to 3 kVA )