4
Product overview | 02 13 Intrinsically safe products and SIL devices D6000 Series Modules suitable for SIL 2 applications according to IEC61508, IEC61511 Single or multichannel versions available Configuration components are easily accessed by removing the side cover DIP switch configurability for easy field setup LED indication for power, signal status and line fault conditions Modules accept DC power supply over a wide range for 24 Vdc (20-30 Vdc) applications Wide operating temp. range: -40 to +60/+70 °C FULL RANGE OF GALVANIC ISOLATORS FOR NON-INTRINSICALLY SAFE APPLICATIONS D5000 Series Installation directly in Zone 2 - Division 2 Certified for 20 years of useful lifetime DIN-Rail, Power Bus or Custom Termination Boards Installation Slim modules (12,5 mm width) Single or Dual channel Up to SIL 3 certification Marine Type Approval and G3 Coating SIL 2 / SIL 3 INTRINSICALLY SAFE ISOLATORS Full range of Galvanic Intrinsically Safe Isolators for SIL 2 and SIL 3 applications MODBUS From the latest intrinsically safe isolators to safety relays for high integrity applications, to enhanced power supply units and systems, here you can find a complete overview of the product range of GM International. Our products are certified up to SIL 3, offering the highest levels of functional safety for high integrity and critical applications. Detailed descriptions of our product series with general features, related accessories, and technical selection tables to support you with the product that suits your application are available on our website www.gmintsrl.com. Galvanic Isolators for Non-Intrinsically Safe applications

Product overview Intrinsically safe products and SIL devicesmutiaraengineering.com/shop/image/data/Images/gmi_product_list.pdf · Product overview 02 13 Intrinsically safe products

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product overview Intrinsically safe products and SIL devicesmutiaraengineering.com/shop/image/data/Images/gmi_product_list.pdf · Product overview 02 13 Intrinsically safe products

Product overview | 02

13

Intrinsically safe products and SIL devices

D6000 Series

• Modules suitable for SIL 2 applications according to IEC61508, IEC61511• Single or multichannel versions available• Configuration components are easily accessed by removing the side cover• DIP switch configurability for easy field setup• LED indication for power, signal status and line fault conditions• Modules accept DC power supply over a wide range for 24 Vdc

(20-30 Vdc) applications• Wide operating temp. range: -40 to +60/+70 °C

FULL RANGE OF GALVANIC ISOLATORS FOR NON-INTRINSICALLY SAFE APPLICATIONS

D5000 Series

• Installation directly in Zone 2 - Division 2• Certified for 20 years of useful lifetime• DIN-Rail, Power Bus or Custom Termination Boards Installation• Slim modules (12,5 mm width) Single or Dual channel• Up to SIL 3 certification• Marine Type Approval and G3 Coating

SIL 2 / SIL 3 INTRINSICALLY SAFE ISOLATORS

Full range of Galvanic Intrinsically Safe Isolators for SIL 2 and SIL 3 applications

MODBUS

From the latest intrinsically safe isolators to safety relays for high integrity applications, to enhanced power supply units and systems, here you can find a complete overview of the product range of GM International. Our products are certified up to SIL 3, offering the highest levels of functional safety for high integrity and critical applications.

Detailed descriptions of our product series with general features, related accessories, and technical selection tables to support you with the product that suits your application are available on our website www.gmintsrl.com.

Galvanic Isolators for Non-Intrinsically Safe applications

Page 2: Product overview Intrinsically safe products and SIL devicesmutiaraengineering.com/shop/image/data/Images/gmi_product_list.pdf · Product overview 02 13 Intrinsically safe products

02 | Product overview

14

Safety Relays

• Compatible with DO Card Line Monitoring Pulse Test• Complete line and load monitoring available on SMART RELAY• High availability and safety both for NE and ND loads• SIL 2 certified Modbus RTU RS485 supported• Coil-to-contact SIL 3 - TÜV Certified• Extended T-proof Times• Available for all Safety Function; ETS or DTS or Inverted

SIL 3 HIGH INTEGRITY SAFETY RELAYS

MODBUS

PSx1200 Series

• Hot Swapping Certified in Zone 2• Installation in Hazardous Area, close to the load: Less cables, lower

voltage drop, lower costs• Two or more Units can be paralleled for Redundancy or additional

power with automatic load sharing without the need of external high dissipation diodes

• Continuous operation also in case of short on the output thanks to the High Fuse Breaking Capacity feature

• Marine Type Approval and G3 Coating

SIL 2 / SIL 3 POWER SUPPLIES

PSS1250

MODBUS

D1000 Series

• Installation also directly in Zone 2• Available for specific application and with Universal Input• DIN rail or Termination Boards Installation

SIL 2 / SIL 3 INTRINSICALLY SAFE ISOLATORS

MODBUS

D1042Q

SIL 3 Safety Relays according to IEC IEC 61508 / 61511, with or without Line and Load Monitoring Detection

Page 3: Product overview Intrinsically safe products and SIL devicesmutiaraengineering.com/shop/image/data/Images/gmi_product_list.pdf · Product overview 02 13 Intrinsically safe products

Product overview | 02

15

T3000 Series

• ATEX, FM & FM-C, Russian certifications• Large LCD Display, 20 mm high• Limited voltage drop (less than 1 V)• IP66 Enclosure with 2 separated chambers• Wall, Pipe-Post, or Panel mounting• Zone 0, IIC T5 / T6 or Div. 1 Installation• In-field configurability via dedicated push-buttons

- decimal point - indicated range between -19999 and +19999 - direct or reverse indication

• Under and Over range detection via blinking display• Protected slot available for engineering value label

LOOP POWER I.S. FIELD DISPLAY

Loop Power I.S. Field Display for Temperature and Analog or Frequency Signals

Termination Boards

• Suitable to host 8/16/32 D5000 or D5200 SIL 3 modules 12.5mm/22.5mm wide, single or double channel, up to 64 channels

• AI/AO – DI/DO – Temperature: Single or double channels• Signal converter, Safety Relay: Single or double channel• 24 Vdc redundant power supply, with window voltage monitoring

and corresponding relay fault output• Boards are available with custom connectors to directly interface

any system PLC / DCS / ESD• Cumulative fault relay output• Redundancy available

UNIVERSAL TERMINATION BOARDS

HART Multiplexer System

• Reduced components: only 31 multiplexer modules GM5700 to control 7936 channels

• Less spare parts: stock is substantially reduced• Wirings are reduced: less components, less cables, less wirings• Increased performances: 115.200 bps baud rate• Certified for SIL 3 applications: our HART Multiplexer System is suitable

for SIL 3 applications according to IEC 61508 and IEC 61511

COST-EFFECTIVE HART INTERFACE SOLUTION

Standard or customized Termination Boards with customizable patch cable

HART Interface System for IS and Non-IS signals

Page 4: Product overview Intrinsically safe products and SIL devicesmutiaraengineering.com/shop/image/data/Images/gmi_product_list.pdf · Product overview 02 13 Intrinsically safe products

02 | Product overview

16

Software and configuration tools

Software and configuration tools facilitate selection, parameterization, and operation of several GM International components. Visit our website www.gmintsrl.com to find a wide range of customized softwares and online tools.

CONFIGURATION SOFTWARES AND WEB-BASED TOOLS

Configuration software

D9000 Series

• SIL 3 according to IEC 61508:2010 Ed.2• Input from Zone 0 (Zone 20), installation in Zone 1 and 2• Disconnection of signal circuit by disconnect knife• Protection of a floating double wire in intrinsically safe circuits• High Density, 6.2 mm per channel• HART compatible• Covers available to terminate a row of D9024S

SURGE PROTECTORS

D9024S

D2000 Series

• Field units can be placed up to 4 km from Gateway• Drastically reduces field wiring and installation costs• Eliminates the need of PLC - DCS AI cards• Gateway D2050M can be installed in Zone 1 / Div. 1 by using an

explosion proof enclosure

INTRINSICALLY SAFE TEMPERATURE AND DIGITAL MULTIPLEXERS

Intrinsically Safe Multiplexer