Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
PRODUCT LINE
OVERVIEW
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Take-aways
2
TSI has handheld, portable and remote instruments
Model numbers give sample flow rate and minimum particle size
You can win with TSI products
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ Exposure assessment
+ Locate contaminant sources
+ Monitor particle size distributions
+ Check manufacturing processes
+ IAQ investigations
TSI Product Overview
Spot-Checks
3
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ 0.1 CFM, 3-6 Channels
+ 0.3 µm -10 µm
+ On board memory
TSI Product Overview
930X Handheld
4
9303 – 3 channel 9306 – 6 channel
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Handheld Instrument
Components
5
• Plastic case
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ Test, monitor and certify cleanroom environments (clean zones) for pharmaceuticals, medical devices, semi-conductor, aerospace.
+ Test filter performance and certify efficiency
+ Typically ISO 14644-1
TSI Product Overview
Certification
7
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ 6 channels
+ 0.3 m to 25 m particle detection
+ 1 CFM to 100 l/min flow rates
+ ISO 14644 report generation
+ On board memory
+ TrakPro Lite Secure data download
TSI Product Overview
9XXX Portables
8
Model
Minimum Particle
Size Flow
9310 0.3 m 1.0 cfm (28.3 lpm)
9350 0.3 m 50 lpm
9550 0.5 m 50 lpm
9500 0.5 m 100 lpm
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Flow Rate & Sample Time
9
Sample Time per Location (minutes)
EU GMP Annex 1
Grade Class Limit
Volume (l)
0.1 cfm (2.83
l/min)
1.0 cfm (28.3
l/min)
1.7 cfm (50
l/min)
3.5 cfm (100
l/min)
A 20 1000 353 35 20 10
B 29 6890 244 24 14 7
C 2900 6.9 2 1 1 1
D 29000 0.69 1 1 1 1
+ For 5.0 m particles
+ 𝑉𝑜𝑙𝑢𝑚𝑒(𝑙) =20
𝐶𝑙𝑎𝑠𝑠 𝐿𝑖𝑚𝑖𝑡∗ 1000
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ Continuous Monitoring for cleanroom environments (clean zones) for electronics industry
+ 8 channels
+ 0.100µm to 10.0µm particle detection
+ 1.0 CFM (28.3L/min) sample flow rate
+ ISO 14644 report generation
+ On board memory
+ TrakPro Lite Secure data download
TSI Product Overview
9110 Portable
10
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Portable Instrument
Components
11
+ Passivated stainless steel case • Non-shedding
• Easy to clean / disinfect
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Using Portables and
Handhelds
12
Measurements
Start Sampling
Zone
Location
Sample Data
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Zones Setup
Identify and save the location information associated with collected samples.
Recipes Setup
Save a group of settings (a recipe) that you use over and over so you don’t have to reset individual settings.
Environment Setup
Sets which units are preferred for displaying environmental measurements taken using optional measurement probes.
System Setup
Change Power On Password, Setup Password, System Configuration, Print Settings, Print Schedule and Clear Samples
Purge Purge residual particles from flow path.
Info Display instrument information such as model number, firmware version, serial number, etc.
Device Setup
Set Date and Time, Screen Alignment, Communications, Regional Settings, and get device information.
Using Portables and
Handhelds
13
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Using Portables and
Handhelds
14
Change Units
Export Data
Print Data
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Using Portables and
Handhelds
15
Standard
Class
Exclude Data
Zone
Generate Report
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
TSI Product Overview
TrakPro Lite Secure
+ Data download software for portable and handheld devices
+ Create, modify, delete, and export AeroTrak zones, recipes, and sample point names
+ Manage large quantities of data
+ Report Generation
+ Enables 21CFR Part 11 compliance
16
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
17
Testing Monitoring
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ Continuous Monitoring for cleanroom environments (clean zones) for pharmaceuticals, medical devices, semi-conductor, aerospace, etc.
TSI Product Overview
Monitoring
18
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ REQUIRES Central vacuum system
+ 2 – 4 channels
+ 0.2 – 5.0µm particle detection
+ 0.1 or 1.0 CFM (2.83 or 28.3 L/min) sample flow rate
+ VHP-resistant models available
TSI Product Overview
7xxx Remote
19
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ REQUIRES Central vacuum system
+ 0.100 – 10.0µm particle detection
+ 8 channels
+ 1.0 CFM (28.3L/min) sample flow rate
+ For electronics industry
TSI Product Overview
7110 Remote
20
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ Central vacuum system not required
+ VHP-resistant model available
+ 4 measurement channels
+ 0.3 – 5.0µm particle detection
+ 1.0 CFM (28.3 L/min) sample flow rate
+ 4 analog inputs
+ 2 analog outputs
TSI Product Overview
6x10 Remote with Pump
21
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
+ Monitor viable particulate levels in real-time
+ Takes place of traditional active air sampling methods
+ Test, monitor and certify cleanroom environments (clean zones) for pharmaceuticals
+ 6 channels
+ 0.5 – 25µm particle detection
+ 1.0 CFM (28.3 L/min) sample flow rate
TSI Product Overview
9510-BD BioTrak
22
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
TSI Product Overview
FMS
23
Facility Monitoring Software
+ Monitoring software suite
+ Database
+ Hot standby failover
+ Device integration (multiple manufacturers supported)
+ Highly scalable
+ Fully GAMP compliant
+ Enables 21CFR Part 11 compliance
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
24
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
TSI Product Overview
Model number system
9 3 1 0
Model
9 – portable
7 – remote
6 – remote with pump
Smallest particle
channel
1 – 0.1µm
2 – 0.2µm
3 – 0.3µm
5 – 0.5µm
Sample Flow Rate
01 – 0.1 CFM (2.83L/min)
10 – 1.0 CFM (28.3L/min)
50 – 1.77 CFM (50L/min)
00 – 3.53 CFM (100L/min)
Exceptions
03 – 9303 Handheld
06 – 9306 Handheld
25
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
TSI Product Overview
Model number system
7 2 0 1
Model
9 – portable
7 – remote
6 – remote with pump
Smallest particle
channel
1 – 0.1µm
2 – 0.2µm
3 – 0.3µm
5 – 0.5µm
Sample Flow Rate
01 – 0.1 CFM (2.83L/min)
10 – 1.0 CFM (28.3L/min)
50 – 1.77 CFM (50L/min)
00 – 3.53 CFM (100L/min)
26
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
TSI Product Overview
Model number system
9 5 0 0
Model
9 – portable
7 – remote
6 – remote with pump
Smallest particle
channel
1 – 0.1µm
2 – 0.2µm
3 – 0.3µm
5 – 0.5µm
Sample Flow Rate
01 – 0.1 CFM (2.83L/min)
10 – 1.0 CFM (28.3L/min)
50 – 1.77 CFM (50L/min)
00 – 3.53 CFM (100L/min)
27
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
TSI Product Overview
Model number system
9 3 0 6
Model
9 – Handheld
Smallest particle
channel
3 – 0.3µm
# of Channels
03 – 3 channels
06 – 6 channels
28
10/20/2016 © TSI Incorporated
TSI CONFIDENTIAL
Conclusion
29
TSI has handheld, portable and remote instruments
Model numbers give sample flow rate and minimum particle size
You can win with TSI products