8.98 / 00073065 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003 - 0 Harlow, Essex CM20 2TT Coatesville, PA 19320 Fax (0661) 6003 - 607 Phone (01279) 63 55 33 Phone 610 - 380 - 8002 Telex 49 701 juf d Fax (01279) 63 52 62 800 - 554 JUMO email [email protected] Fax 610 - 380 - 8009 Data Sheet 20.2900 Page 1/21 Reference electrodes For use in pH measurement together with a glass electrode (e.g. 2G-2-U) For use in redox measurement together with a metal electrode (e.g. 2M-2-Pt) For use in pH measurement together with an antimony electrode (e.g. 2MP-2-Sb) Standard dimensions 120 x 12 mm (DIN 19 263) Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering Customized styles on request With ceramic diaphragm 1mm dia. Ag/AgCl conductive system in cartridge style Gel- or KCl-filled, free of silver ions Ex-stock standard electrode (can be supplied within 3 working days) Sales No. Type 20/00083865 2B-2-G Types 2B- Reference electrode Type of electrode head 1- cap N 2- cap N with thread Pg 13.5 Electrolyte G gel-filled operating temperature -5 to +990 o C pressure-resistant up to 10 bar KCl KCl-filled operating temperature -5 to +100 o C unpressurized applications Type designation for your order: 2B- Style notes: 2B-2-G cartridge ceramic diaphragm Product line 202902

Product line 202902 Reference electrodes - · PDF file8.98 / 00073065 M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany Data Sheet 20.2900 Page 3/21 Gel-filled pH combination electrodes

  • Upload
    vudieu

  • View
    228

  • Download
    2

Embed Size (px)

Citation preview

8.98 / 00073065

M. K. JuchheimGmbH & Co UK USA

Jumo Instrument Co. Ltd. Jumo Process Control Inc.36035 Fulda, Germany Temple Bank, Riverway 735 Fox ChasePhone (0661) 6003 - 0 Harlow, Essex CM20 2TT Coatesville, PA 19320Fax (0661) 6003 - 607 Phone (01279) 63 55 33 Phone 610 - 380 - 8002Telex 49 701 juf d Fax (01279) 63 52 62 800 - 554 JUMOemail [email protected] Fax 610 - 380 - 8009

Data Sheet 20.2900 Page 1/21

Reference electrodes❑ For use in pH measurement together with a glass electrode (e.g. 2G-2-U)❑ For use in redox measurement together with a metal electrode (e.g. 2M-2-Pt)❑ For use in pH measurement together with an antimony electrode (e.g. 2MP-2-Sb)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ With ceramic diaphragm 1mm dia.❑ Ag/AgCl conductive system in cartridge style❑ Gel- or KCl-filled, free of silver ions

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00083865 2B-2-G

Types

2B- Reference electrode

Type of electrode head1- cap N2- cap N with thread Pg 13.5

ElectrolyteG gel-filled operating temperature -5 to +990oC pressure-resistant up to 10 barKCl KCl-filled operating temperature -5 to +100oC unpressurized applications

Type designation for your order:

2B-

Style notes:

2B-2

-G

cartridge

ceramicdiaphragm

Product line 202902

8.98 / 00073065

Data Sheet 20.2900 Page 2/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

pH glass electrodes❑ For pH measurement together with a reference electrode (e.g. 2B-2-G)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00083302 2G-2-U

Types

2G- pH glass electrode

Type of electrode head1-2-

cap Ncap N with thread Pg 13.5

Membrane glassUC

HT

universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)glass C(fluoride-resistant up to 500 mg/I HF)

operating temp. 0 to +80oC, pH 0-11

high-temperature glass(also suitable for highly alkaline applications)

operating temp.- 0 to +130oC, pH 1-14

Type designation for your order:

2G-

2G-2

-U

spherical membrane

Style notes:

Product line 202901

8.98 / 00073065

Data Sheet 20.2900 Page 3/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Gel-filled pH combination electrodeswith glass shaft❑ Standard electrode for general pH measurement❑ Salt reservoir for longer operational life as standard❑ Versions with PTFE ring diaphragm are particularly suitable for hostile environment

e.g. sewage-treatment plants, oily and heavily contaminated media❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Integral Pt100 possible (version with cap SMEK threaded Pg 13.5)❑ Customized styles on request❑ Pressure-resistant up to 10 bar❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions❑ Special frost-resistant reference electrolyte on low-temperature electrode (3 x ceramic diaphragm is recommended)

Ex- stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00303348 2GE-1-G-U-120/00300151 2GE-2-G-U-120/00300169 2GE-2-G-HT-120/00321035 2GE-2-G-U-T

Types

2GE- Combination glass electrode

Type of electrode head1- cap N2-9-

cap N threaded Pg 13.5cap SMEK threaded Pg 13.5(on version with integral temperature sensor)

FillingG- gel-filled (filler closed with tubing )

Membrane glassU-HT-

K-C-

TT-

universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)high-temperature glass(suitable for highly alkaline applications)

operating temp.- 0 to +90oC, pH 0-14

rounded glass for rounded membrane operating temp. -5 to +80oC, pH 0-12 (14)glass C(fluoride-reistant up to 500mg/I HF)

operating temp. 0 to +80oC, pH 0-11

low-temperature glass operating temp.-30 to +30oC, pH 0-11Diaphragm1 1 x ceramic diaphragm, 1 mm dia.3 3 x ceramic diaphragm, 1 mm dia.T PTFE ring diaphragm

Type designation for your order:

2GE- G-

2GE

-2-G

-U-1

Style notes:

spherical membrane

PTFEring diaphragm

ceramicdiaphragm

rounded membrane

ceramicdiaphragm

spherical membrane

Product line 202903

8.98 / 00073065

Data Sheet 20.2900 Page 4/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Gel-filled sealed pH combination electrodeswith glass shaft❑ Standard electrode for general pH measurement❑ Versions with PTFE ring diaphragm are particularly suitable for hostile environment

e.g. sewage-treatment plants, oily and heavily contaminated media.❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Integral Pt100 possible (version with cap SMEK threaded Pg 13.5)❑ Customized styles on request❑ Pressure-resistant up to 0.5 bar❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00300147 2GE-1-GV-U-120/00300148 2GE-2-GV-U-1

Types

2GE- Combination glass electrode

Type of electrode head1- cap N2-9-

cap N threaded Pg 13.5cap SMEK threaded Pg 13.5(only on version with integral temperature sensor)

FillingGV- gel-sealed

Membrane glassU- universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)HT- high-temperature glass

(suitable for highly alkaline applications)operating temp. -0 to +90oC, pH 0-14

K- rounded glass (for rounded membrane) operating temp. -5 to +80oC, pH 0-12 (14)C- glass C

(fluoride-resistant up to 500mg /l HF)operating temp.- 0 to +80oC, pH 0-11

Diaphragm1 1 x ceramic diaphragm, 1 mm dia.T PTFE ring diaphragm

Type designation for your order:

2GE- GV-

2GE

-2-G

V-U

-1

Style notes:

spherical membrane

PTFEring diaphragm

ceramicdiaphragm

rounded membrane

ceramicdiaphragm

spherical membrane

Product line 202903

8.98 / 00073065

Data Sheet 20.2900 Page 5/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Gel-filled, sealed pH combination electrodeswith plastic shaft❑ Standard electrode for general pH measurement❑ Fracture-resistant shaft material made of high-quality plastic which is resistant to acidic and caustic solutions❑ In 2-chamber version suitable for media which poison the reference system, e.g. heavy metals❑ KCI reservoir as standard, for longer operational life (on Doka version)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Integral Pt100 possible (version cap SMEK threaded Pg 13.5)❑ Customized styles on request❑ Pressure-resistant up to 10 bar❑ With glass silk diaphragm ❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00303398 2GEP-2-GV-Doka-U-S

Types:

2GEP- Combination glass electrode with plastic shaft

Type of electrode head1- cap N2-9-

cap N threaded Pg 13.5cap SMEK Pg 13.5(only on version with integrated temperatur sensor)

FillingGV- gel-sealedGV-Doka- gel-sealed in 2-chamber version

Membrane glassU- universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)HT- high-temperature glass

(suitable for highly alkaline applications)operating temp.- 0 to +80oC, pH 0-14

C- glass C(fluoride-resistant up to 500mg/l HF)

operating temp. -0 to +80oC, pH 0-11

Protective basketS with protective basketO without protective basket

Type designation for your order:

2GEP-

2GE

P-2

-GV

-U-0

spherical membrane

glass silk

Style notes:

diaphragm

without protective basket

Product line 202903

spherical membrane

glass silkdiaphragm

with protective basket

8.98 / 00073065

Data Sheet 20.2900 Page 6/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

KCl-filled pH combination electrodeswith glass shaft❑ Standard electrode for general pH measurement❑ Version with HT-membrane glass usable up to 130oC❑ Possibility of re-filling liquid KCI via the filler on the shaft,

via the tubing nipple or the pressure head❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 0.5 bar❑ Pressure-resistant up to 10 bar on version 2GE-2-D-... and when suitably pressurized❑ Ag/AgCl conductive system in cartridge style❑ KCl filling free of silver ions

Available accessory:Pressure head Type 2991-0-0025Sales No. 20/00315791

Types

2GE- Combination glass electrode

Type of electrode head1- cap N1-Pg- cap N, nipple and thread Pg 13.5 cemented on2-D- cap N threaded Pg 13.5,

prepared for measurements with Type 2991-0-0025 pressure head (also see page 7)

FillingKCl- KCl filling

Membrane glassU- universal glass (standard) operating temp. -5 to +080oC, pH 0-12 (14)HT- high-temperature glass

(suitable for highly alkaline applications)operating temp.- 0 to +130oC, pH 0-14

K- rounded glass (for rounded membrane) operating temp. -5 to +080oC, pH 0-12 (14)C- glass C

(fluoride-resistant up to 500mg/l HF)operating temp.- 0 to +080oC, pH 0-11

CM- insertion version operating temp. -5 to +080oC, pH 0-12 (14)DS- glass DS (suitable for steam

sterilisation, sterile media)operating temp. 0 to +135oC, pH 1-14

Diaphragm1 1 x ceramic diaphragm, 1 mm dia.2 2 x ceramic diaphragm

(standard on insertion version), 1 mm dia.T PTFE ring diaphragm (for gel filling and glass shaft only)Schliff ground diaphragm

Type designation for your order:

2GE- KCl-

2GE

-1-P

g-K

CL-

HT

-1

roundeddiaphragmring diaphragm

Style notes:

ceramicdiaphragmceramic

PTFEspherical

grounddiaphragm

Product line 202903

spherical

insertionversion

spherical

diaphragmceramic

membrane membrane membrane membrane

8.98 / 00073065

Data Sheet 20.2900 Page 7/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

sealing cap

Electrodeswith tubing nipple

Electrodes

nipplefor topping up

diaphragmring diaphragm

Style notes:

ceramicdiaphragmceramic

PTFE

with mountedpressure head

thread Pgcemented on

tubeconnection(pressurization,connection of a KClreservoir, etc.)

pressure head

Electrode,preparedforpressure head

spherical rounded membrane spherical membrane

grounddiaphragm

e.g.2GE-2-D-KCl-U-1

spherical membrane

electrolyte

membrane

pressure headType 2991-0-0025

8.98 / 00073065

Data Sheet 20.2900 Page 8/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

pH combination electrodeswith attached cable connection❑ Standard electrode for general pH measurement❑ Version with CM membrane glass

(insertion electrode) suitable for pH measurementsin semi-solid media (earth, meat, fruit etc.)spear tip 6 mm dia.

❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting length (e.g. 160 x 12 mm, 225 x 12 mm)

have to be specified in plain text when ordering❑ Customized styles on request

Types

Combination glass electrode2GE- with glass shaft2GEP- with plastic shaft

Type of electrode head3- rubber cap for 3 mm cable diameter, black4- plastic cap for 3mm cable diameter, black

FillingG- gel filling (filler closed with tubing)GV- gel-sealedKCl- KCl filling (filler closed with tubing)

Membrane glassU- universal glass (standard) Einsatz-Temperatur -5...+080oC, pH 0-12 (14)HT- high-temperature glass

(also for highly alkaline applications)Einsatz-Temperatur -5...+130oC, pH 1-14(bei Gel-Füllung -5...+080oC)

K- rounded glass (for rounded membrane) Einsatz-Temperatur -5...+080oC, pH 0-12 (14)C- glass C

(fluoride-resistant up to 500mg /l HF)Einsatz-Temperatur -5...+080oC, pH 0-12 (14)

CM- insertion version Einsatz-Temperatur -5...+080oC, pH 0-12 (14)

Diaphragm1- 1 x ceramic diaphragm, 1 mm dia.

(only with Type 2GE-...)2- 2 x ceramic diaphragm (standard on insertion version)T- PTFE ring diaphragm (only with gel filling and glass shaft)Schliff- ground diaphragmGS- glass silk diaphragm (Type 2GEP-... only)

Cable length. . . . specified in metres

Plug connectionohne no plugBNC with BNC plugDIN with DIN plugLemo with Lemosa plug

Type designation for your order:

spher.membrane

diaphragm

Style notes:

diaphragmceramic

spher.membrane

grounddiaphragm

Product line 202903

2GE

-3-K

Cl-

CM

-2-B

NC

diaphragmceramic

insertionversion

ring diaphragmPTFE

spher.membraneroundedmembrane

spher.membrane

glass silkdiaphragm

+ prot. basket

8.98 / 00073065

Data Sheet 20.2900 Page 9/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Metal electrodes for redox measurement❑ In conjunction with a reference electrode (e.g. 2B-2-G) for redox measurement❑ Active platinum element (pin or rounded tip)

for use in e.g. chromate reduction, nitrite oxidation, swimming pool monitoring❑ Active gold element (available only as pin)

for use in e.g. cyanide oxidation❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar

Types

2M- Metal electrode

Type of electrode head1- cap N2- cap N threaded Pg 13.5

ActiveelementPt platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +130oCPtK platinum tip 5.5 mm dia. operating temp. -10 to +130oCAu gold pin 1 mm dia. length = 8 mm operating temp. -10 to +130oC

Type designation for your order:

2M-

2M-1

-PtK

Au- or Pt-pin

Style notes:

Pt-tip

Product line 202904

8.98 / 00073065

Data Sheet 20.2900 Page 10/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Gel-filled metal combination electrodeswith glass shaft for redox measurement❑ Standard electrode with active platinum element for redox measurement

e.g. for chromate reduction, nitrite oxidation, swimming pool monitoring❑ Standard electrode with active gold element for redox measurement

e.g. for cyanide oxidation❑ General laboratory measurements❑ With salt reservoir as standard for longer operational life❑ Versions with PTFE ring diaphragm particularly suitable for hostile environments,

such as sewage-treatment plants, oily and heavily polluted media❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar (version GV pressure-resistant up to 0.5 bar)❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00300394 2ME-1-G-PtK-120/00300397 2ME-2-G-PtK-1

Types

2ME- Metal combination electrode

Type of electrode head1- cap N2- cap N threaded Pg 13.5

FillingG- gel filling (filler closed with tubing)GV- gel filling sealed

ActiveelementPt- platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +90oCPtK- platinum tip 5.5 mm dia. operating temp. -10 to +90oCAu- gold pin 1 mm dia. length = 8 mm operating temp. -10 to +90oC

Diaphragm1 1 x ceramic diaphragm 1 mm dia.T PTFE ring diaphragm (only with gel filling and glass shaft)

Type designation for your order:

2ME-

Styles notes:

2ME

-2-G

-PtK

-1

Au- or Pt-pin Pt-tip

ceramic diaphragmceramic diaphragm

ringdiaphragm

Pt-tip

Product line 202905

PTFE

8.98 / 00073065

Data Sheet 20.2900 Page 11/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Gel-filled, sealed metal combination electrodeswith plastic shaft for redox measurement❑ Standard electrode with active platinum element for redox measurement

e.g. for chromate reduction, nitrite oxidation, swimming pool monitoring❑ Standard electrode with active gold element for redox measurement

e.g. for cyanide oxidation❑ Fracture-resistant shaft material of high-quality plastic, resistant against acidic and caustic solutions❑ In 2-chamber version suitable for media which poison the reference system

e.g. heavy metals, sulfur compounds etc.❑ KCI reservoir as standard for longer life (on Doka version)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plan text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar❑ With glass silk diaphragm❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00084009 2MEP-2-GV-Doka-Pt-O20/00084011 2MEP-2-GV-Doka-PtK-O

Types

2MEP- Metal combination electrode with plastic shaft

Type of electrode head1-2-

cap N cap N threaded Pg 13.5

FillingGV- gel-sealedGV-Doka- gel-sealed in 2-chamber version

ActiveelementPt- platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +90oCPtK- platinum tip 5.5 mm dia. operating temp. -10 to +90oCAu- gold pin 1 mm dia. length = 8 mm operating temp. -10 to +90oC

Protective basketO without protective

basket

Type designation for your order:

2MEP- O

Style notes:

2ME

P-2

-GV

-PtK

-0

glass silkdiaphragm

Pt-or Au-pin

glass silkdiaphragm

Pt-tip

Product line 202905

8.98 / 00073065

Data Sheet 20.2900 Page 12/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Metal combination electrodeswith attached cable connection❑ Standard electrode for general redox measurement❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm)

have to be specified in plain text when ordering❑ Customized styles on request

Types

Metal combination electrode2ME- with glass shaft2MEP- with plastic shaft

Type of electrode head3- rubber cap for cable dia. 3 and 5 mm, black

(also 3 mm in white)4- plastic cap for cable dia. 3 and 5 mm, black

FillingG- gel filling (filler closed with tubing)GV- gel-sealedKCl- KCl filling (filler closed with tubing)

ActiveelementPt- platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +90oCPtK- platinum cap 5.5 mm dia. operating temp. -10 to +90oCAu- gold pin 1 mm dia. length= 8 mm operating temp. -10 to +90oC

Diaphragm1- 1 x ceramic diaphragm, 1 mm dia.

(with plastic shaft, diaphragm material: glass fibre)T- PTFE ring diaphragm (only with gel filling and glass shaft)GS- glass silk diaphragm (Type 2MEP-... only)

Cable length. . . . specified in metres

Plug connectionohne without plugBNC with BNC plugDIN with DIN plugLemo mit Lemosa plug

Type designation for your order:

Product line 202905

2ME

P-3

-GV

-PtK

-GS

-BN

C

Styles notes:

glass silkdiaphragm

Pt-or Au-pin

glass silkdiaphragm

Pt-tipAu- or Pt-pin

ceramic

Pt-tip

ceramicringdiaphragm

Pt-tip

PTFE

diaphragm diaphragm

8.98 / 00073065

Data Sheet 20.2900 Page 13/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Style notes:

Twin metal electrodesfor redox measurement❑ For use in e.g. titration and amperometric redox potential measurements❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Operating temperatures up to 130oC❑ Pressure-resistant up to 10 bar

Types

2MD- Twin metal electrode

Type of electrode head1- cap N2- cap N threaded Pg 13.5

ActiveelementPt-Au platinum pin and gold pin 1 mm dia. length 8 mmPt-Pt platinum pin and

platinum pin1 mm dia. length 8 mm

Type designation for your order:

2MD-

2MD

-2-P

t-A

u

Pt-Au orPt-Pt pin

Product line 202906

8.98 / 00073065

Data Sheet 20.2900 Page 14/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Style notes:

Metal electrode for pH measurement (antimony electrode)❑ In conjunction with a reference electrode (e.g. 2B-2-G)

and an electrolyte bridge for pH measurement, e.g. in media containing hydrofluoric acid❑ NOTE: transmitter must have an antimony input

(e.g. 2P1-transmitter to Data Sheet 20.2770 with extra Code /40)❑ Fracture-resistant high-quality plastic shaft material, resistant to acidic and caustic solutions❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar

Types

2MP- Metal electrode for pH measurement with plastic shaft

Type of electrode head2- cap N threaded Pg 13.5

ActiveelementSb antimony operating temp. -10 to +80oC

Type designation for your order:

2MP- 2- Sb

2MP

-2-S

b

antimonycylinder

Product line 202904

8.98 / 00073065

Data Sheet 20.2900 Page 15/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Diaphragm tubes❑ For constructing an electrolyte bridge❑ Diaphragm tubes are used in conjuction with a pH glass electrode in a suitable fitting

(e.g. 2TA-PP-63 to Data Sheet 20.2810) for pH measurement in critical media.They form the diaphragm of a reference electrode in the measurement medium which is inside a separate vessel(e.g. KCl reservoir). This prevents the poisoning of the reference system.In addition, the blocking of the diaphragm (due to the larger surface) is delayed in time.

❑ Applications: emulsions, varnish, paint, photochemicals, liquids which poison the reference system,media containing sulfide, part-aqueous and non-aqueous media miscible or immiscible in water.

❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Customized styles on request.❑ Pressure-resistant to 6 bar when using a pressure-resistant KCl reservoir❑ With PTFE diaphragm 5 mm dia.❑ Supplied together with 3 spare PTFE diaphragms❑ With tubing clamp fitting

for connecting a connection tube of 6 x 1.5 mm cross-section to the KCl reservoir

Available accessory

Sales No.20/00304567 10 spare PTFE diaphragms

Types

2908- Diaphragm tubes

Shaft material16 PP temperature -10 to +080oC26 PVDF temperature -10 to +135oC

Type designation for your order:

2908-

2908

-16

connecting cablee.g. 2992-2(5)-0

immersionfitting2TA-PP-63-3/52

transmitter/controllere.g. 262501(Data Sheet 20.2501) e.g.

liquidKClfillingKCl

reservoir

diaphragm tubee.g. 2908-16

ref.electrodee.g. 2B-2-G

e.g. glass,metal orantimonyelectrode

connecting cablee.g. 2992-2(5)-0

transmitter/controllere.g. 262501(Data Sheet 20.2501)

pH coaxial cablee.g. 2992-2(5)-0

diaphragm tubee.g. 2908-16

flow-through fitting2DA-G½-PP(Data Sheet 20.2810)

KCI

(for wallmounting)

e.g.liquidKClfilling

ref.electrodee.g. 2B-2-G

tubing

reservoir

Construction example: Flow-through measurement Construction example: Measurement in vessel

Product line 202908

glass electrodee.g. 2G-2-HT(or antimony electrode)

8.98 / 00073065

Data Sheet 20.2900 Page 16/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Glass conductivity cells❑ For conductivy measurements in acqueous solutions❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Cell constant: K = 1 +/- 10%❑ Integral Pt100 possible (version with cap SMEK threaded Pg 13.5)❑ Pressure-resistant to 10 bar

Types

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00303396 2LF-2-Pt

2LF- Conductivity cell

Type of electrode head1- cap N2-9-

cap N threaded Pg 13.5cap SMEK threaded Pg 13.5(only on version with integrated Pt100)

ActiveelementPt platinum platinised operating temp. -10 to +160oC max. range 0—100mS/cmPtU platinum unplatinised operating temp. -10 to +160oC max. range 0—001mS/cm

Type designation for your order:

2LF-

2LF

-2-P

t

Product line 202907

8.98 / 00073065

Data Sheet 20.2900 Page 17/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Compensation thermometers❑ For temperature measurement and automatic temperature compensation in pH and conductivity measurement❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Sensor to DIN 43 760 Class B (Pt100)❑ Pressure-resistant to 10 bar❑ Time constant: T0.5 = 0.8sec; T0.9 = 4sec (Pt100)❑ Customized styles on request❑ Operating temperature -10 to +135oC

Ex-stock standard electrode(can be supplied within 3 working days)

Sales No. Type20/00300443 2K-2

2K- Compensation thermometer

Type of electrode head01 cap N; Pt10002 cap N threaded Pg 13.5; Pt10011 cap N; Pt100021 cap N threaded Pg 13.5; Pt100003 twin Pt100; attached cable 3 m; Pg 13.5 cemented on

Type designation for your order:

2K-

2K-2

attached cableL = 3m

Type 2K-3

Type L Ø

2K-115 4.5-0.5

2K-2

2K-1124 2.8-0.5

2K-21

2K-3 22 4.5-0.5

Product line 202920

8.98 / 00073065

Data Sheet 20.2900 Page 18/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Connection cables and plugs for electrodes

Ex-stock standard cables(can be supplied within 3 working days)

Sales No. Type20/00082672 2992-2(3)-020/00082673 2992-2(5)-020/00082674 2992-2(8)-020/00085976 2992-2(100)-0

Instrument plug(can be supplied within 3 working days)

Sales No. Type20/00058082 2990-00-1 plug to DIN 19 262 for 5 mm cable dia.20/00058327 2990-00-21 BNC plug, 3 mm cable dia.20/00059253 2990-00-22 BNC plug, 5 mm cable dia.20/00064222 2990-00-23 BNC angle plug, 5 mm cable dia.20/00082463 2990-00-3 banana plug, red20/00082464 2990-00-3 banana plug, black20/00061202 2990-00-4 plug N, 5 mm20/00057350 2991-00-0 cable socket N, 5 mm

For pH / redox and conductivity measurementCable end 12990- no plug connection2992- cable socket Type N, rotating2994- cable socket Type SMEK

Cable type01 low-noise coaxial cable diameter: 3 mm, black temperature -25 to +170oC02 low-noise coaxial cable diameter: 5 mm, black temperature -25 to +170oC03 low-noise coaxial cable diameter: 3 mm, black temperature -20 to +130oC04 low-noise coaxial cable diameter: 5 mm, black temperature -20 to +130oC05 stranded wire temperature -20 to +170oC06 stranded wire temperature -50 to +180oC07 low-noise coaxial cable 2 x copper screen (triax cable)

diameter: 5 mm, black temperature -25 to +170oC08 special cable, 2-core, screened (for conductivity)

diameter: 5 mm, grey temperature -05 to +180oC09 special cable, 4-core, screened (for conductivity)

diameter: 5 mm, grey temperature -05 to +180oC10 coaxial cable (SMEK) + 3 stranded wires and screen

diameter: 5.5 mm, black temperature -05 to +180oC

Cable length( . . . ) specify cable length in metres (e.g. 1 = 1 m cable)

Cable end 2-00 no plug connection-01 plug to DIN 19 262-21 BNC plug for 3 mm cable dia.-22 BNC plug for 5 mm cable dia.-23 BNC angle plug for 5 mm cable dia.-03 banana plug-04 plug N for 5 mm cable dia.-06 AMP plug 6.3 mm-07 5-pole diode plug-08 angle connector for 2EL6- (for cables 8 and 9 only)-09 Lemosa plug for 3 mm cable dia.-13 Shieldkon connector with 2AMP plug 6.3 mm

(for 5 mm coaxial cable dia. only)-14 Cinch plug

Type designation for your order:

( . . . )

2992-2(...)-0

Sta

ndar

d c

able

pH

/red

ox

Product line 202990

8.98 / 00073065

Data Sheet 20.2900 Page 19/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

1- cap N

Type of electrode head

2- cap N threaded Pg13.5

3- attached cable with rubber cap

4- attached cable with plastic cap

9- SMEK cap (multi-pole connector))

(compatible with most other caps S8 or GSA)

(compatible with most other caps e.g. S7)

with Pg13.5 thread

Material Noryl

Material Perbunan

Electrodeconnectionheads

Connection cables and plugs for electrodes

no plug connection -6 AMP plug6.3 mm-0

-1 -75-polediode plug

-21

-22

-8angle plugfor 2EL6-(for cables 8 and 9 only)

-23-9 Lemosa plug

for 3 mmcable dia.

-3

-13Banana plug

-4 -14Plug N for5 mm cable dia.

Cinch plug

Cable socket Type N, 2992-..., rotating (can be fitted in factory only)

instrument plug to

BNC plug for

BNC plug for

3 mm cable dia.

5 mm cable dia.

BNC angle plug for5 mm cable dia.

Shieldkonconnector with AMP plug 6.3mm(for 5 mm coaxial cable dia. only)

DIN 19 262

8.98 / 00073065

Data Sheet 20.2900 Page 20/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Buffer solutions to DIN 19 267❑ Technical buffer solutions to DIN 19 267 are used for calibrating pH electrodes

and have proved very successful, particularly for use in industry and industrial laboratories,because they are relatively unaffected by dilution (high buffering capacity).

❑ The effect of the temperature on the pH values of the buffer solution is shown in the tableon the bottle label.The accuracy is ± 0.02 pH units

❑ The buffer solutions indicate the batch no. and the max. recommended use-by date.❑ The bottle tops are coloured, for identification.

Sales No. Description20/00309747 250 ml buffer solution pH 03.07 to DIN 19267 at 20oC20/00344977 250 ml buffer solution pH 04.00 to DIN 19267 at 20oC20/00301070 250 ml buffer solution pH 04.65 to DIN 19267 at 20oC20/00301071 250 ml buffer solution pH 06.80 to DIN 19267 at 20oC20/00338371 250 ml buffer solution pH 07.00 to DIN 19267 at 20oC20/00301072 250 ml buffer solution pH 09.27 to DIN 19267 at 20oC20/00345027 250 ml buffer solution pH 10.00 to DIN 19267 at 20oC

20/00301073 250 ml redox-potential test solution +468mV (at 25oC)

Minimum ordering quantity: 5 units

Cleaners

Sales No. Description20/00307586 250 ml diaphragm cleaner (thiourea solution)20/00307114 250 ml electrode cleaner (pepsin hydrochloric acid solution, protein remover)

Minimum ordering quantity: 5 units

Auxiliary electrolytes

Sales No. Description20/00306215 250 ml 3-molar KCl solution without AgCl (free of silver ions)20/00307585 250 ml 3-molar KCl solution with AgCl (for electrodes with wire conductor in the reference system)

Minimum ordering quantity: 5 units

Conductivity test-solutions

Sales No. Description20/00346056 250 ml KCl 0.01 mol/l001.41 mS/cm20/00346058 250 ml KCl 0.10 mol/l012.88 mS/cm20/00346060 250 ml KCl 1.00 mol/l111.80 mS/cm

Minimum ordering quantity: 5 units

Product line 202950

8.98 / 00073065

Data Sheet 20.2900 Page 21/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany

Simulators❑ Simulators are connected to the transmitter in place of an electrode or measuring cell,

to test connection cables and/or transmitters/controllers (installation test, commissioning etc).❑ Simulation of conductive 2-electrode measuring cells (2H-SLF-1).❑ 2 temperatures, switchable to check temperature compensation (2H-SLF-1).

pH simulatorType 2H-SpH-1Range0—14pH,with selector switch in 1pH stepsOutput signal+414mV to 0 to -414mV,in 59mV steps,corresponding to 0—14pHCalibration accuracy±1% of selected pH valueReference temperature25oCOutput resistance1kOhm (direct) or 1000MOhm (1000M),depending on switch positionSupply 9V block battery (included in delivery)integrated battery check

Conductivity simulator (conductive)Type 2H-SLF-1

Simulation rangewith cell constant C =0.01 to 10.0:conductivity in steps from 2mS/cm to800mS/cm (switchable, see table)

Possible simulations

R / C 0.01 0.1 1.0 3.0 10.0

12.5 V 800 mS 8 mS 80 mS 240 mS 800 mS

25 V 400 mS 4 mS 40 mS 120 mS 400 mS

50 V 200 mS 2 mS 20 mS 60 mS 200 mS

125 V 80 mS 800 mS 8 mS 24 mS 80 mS

250 V 40 mS 400 mS 4 mS 12 mS 40 mS

500 V 20 mS 200 mS 2 mS 6 mS 20 mS

1200 V 8 mS 80 mS 800 mS 2,4 mS 8 mS

2500 V 4 mS 40 mS 400 mS 1,2 mS 4 mS

5000 V 2 mS 20 mS 200 mS 600 mS 2 mS

12.5 kV 800 nS 8 mS 80 mS 240 mS 800 mS

25 kV 400 nS 4 mS 40 mS 120 mS 400 mS

50 kV 200 nS 2 mS 20 mS 60 mS 200 mS

125 kV 80 nS 800 nS 8 mS 24 mS 80 mS

250 kV 40 nS 400 nS 4 mS 12 mS 40 mS

• V 0 0 0 0 0

1000MOhm circuitto check installed pH connection cables for faultsConnectionBNC socket and socket for separate reference electrodePermitted ambient temperature range0 to 50oCCasealuminiumSize70 x 120 x 45 mm

Available connection cablesSales No. Description20/00082906 22-2(1,1)-22,

adapter cable (Fig. 2)BNC/BNC, length 1.1 m

20/00082908 22-2(1,1)-4,adapter cable (Fig. 1)BNC/N plug, length 1.1 m

Calibration accuracy±1% of selected resistancePt100 simulation:25 °C and 75 °C ±1 °Cin 2- wire and 3-wire circuitPermitted ambient temperature0 to 50 °CCasealuminiumSize70 x 120 x 45 mmConnection5-pole diode socket

Available connection cablesSales No. Description20/00082901 7-9(1,1)-0

adapter cable (Fig. 4)diode plug/bare tailslength 1.10 m

20/00082902 7-9(1,1)-6adapter cable (Fig. 3)diode plug/AMP plug6.3 mm, length 1.10 m

(Fig. 1) (Fig. 2)

(Fig. 3) (Fig. 4)

Product line 202711

Product line 202712