FLEXI SOFTTHE MODULAR SAFETY CONTROLLER THAT CLEVERLY INCORPORATES ADVANTAGES
Safety controllers
PR
OD
UC
T I
NF
OR
MA
TIO
N
2
Since 2008, Flexi Soft has been one of the best-selling safety controllers in the area of industrial safety. It is conveniently and freely programmable with software, easy to use, and it can be expan-ded in a variety of ways with modular additions. What makes Flexi Soft more clever is also where
solution for many machines. It has already proved itself on the market more than 50,000 times – and in the broadest range of applications. Flexible in the service of industry. Soft on the company budget.
Today’s Flexi Soft is smarter than ever before thanks to technology such as Flexi Line, a cost-optimized solution for practically unlimited networking between modular machines. Or Flexi Loop,
diagnostics. And it is just as safe to say that design engineers around the world are excited by this solution.
Flexi Soft is a safe bet not only for a large number of systems and machines, but also for various industries. Why is that? Because Flexi Soft is an intelligent solution that networks mo-dular machines. For instance, the masterful technical innovati-on is ideal for protecting hazardous points around presses and
the packaging and electronics industries. Decentralized safety
from Flexi Soft. And, last but not least, it is impossible to ima-gine networking the overlapping safety functions of modular machines – and their integration into standardized system controllers – without Flexi Soft.
Electronics and solar Logistics PackagingMachine building
In many industries, Flexi Soft is the best proof that safety does
a modular safety controller that grows in line with the increa-sing complexity of the applicationSafe and especially straightforward networking without
machine concepts
human–machine interaction minimize downtime
– ESPECIALLY FOR CONTROLLERS
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
3
Contents
Introduction/Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Flexi Soft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Flexi Soft system solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Flexi Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Flexi Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Drive Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Complete solutions from SICK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
4
-
all the components needed by modern safety systems. And, put simply, modular is smarter.
• Main modules with or without safe networking • Expansion modules ‘Standard’ and ‘Safety’ • Gateways into all common bus systems • Motion Control modules
Intelligent advantages secure a modular portfolio.
A cleverer way to go online! Flexi Line networks
• -ty controllers across a wide area without any addressing
• -missioning with no additional hardware
•optimized data transfer
•concept
A smarter way to connect in series! Flexi Loop saves
• Flexi Loop is the answer when it comes to cascading safety switches and sensors within a machine in a way that both reduces cost and supports diagnostics (in accordance with Performance Level e)
• Compatible with sensors from all manufacturers • Transmission of detailed diagnostic information • Includes integrated standard input and output as well as a
sensor power supply • A perfect solution for packaging machines and production
systems in the electronics and solar components industries
Independent thinkers monitor drives safely.
• Perfect integration of safety applications with drive technology
• • Open to all common motor feedback systems and encoders •
numerous drive safety functions
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
5
… AND MORE SOPHISTICATION IN PRACTICE
Thanks to its modular hardware platform, the controller can grow module by module as a given task evolves. This means that Flexi Soft can be perfectly adapted to different applica-tions, saving effort and unnecessary, expensive inputs.
• Optimal granularity avoids unnecessary inputs and outputs • Integration with up to two gateways and twelve expansion
modules • Connection for as many as 296 safety sensors via Flexi Loop • Ability to network up to 32 safety controllers
•and integrated simulation mode
• Large number of logic blocks for each Flexi Soft station in
•together with detailed wiring assistance
10 Minutes to Green with Flexi Soft Designer –
• Flexi Soft gateways support the simple connection of Flexi Soft to all common automation systems
• Rapid troubleshooting with easy access to error and status information for all Flexi Soft modules, including EFI devices
• Remote diagnostics via TCP/IP gateways reduces service call-outs and system downtime
• Up to two different gateways can be used for each Flexi Soft station
enables safe communication with electro-sensitive protective devices. EFI also provides a continuous diagnostic capability.
• • • Operating mode changeover • Analysis of diagnostic signals
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
1 6
Flexi Soft SAFETY CONTROLLERS
Product description
Flexi Soft safety controller from SICK. The Flexi Soft concept offers a whole range of main modules, expansion modules, Motion Control modules, and gateways that can be used to create a
safety application. It is the ideal choice for safeguarding against hazardous points in presses and laser cutting systems used in machine building
in the packaging industry, which uses machines with a large number of doors
-sures. In applications like these, Flexi Soft keeps the amount of wiring used to a minimum. Flexi Soft also makes it possible to network overlapping safety functions in modular machines – and integrate these into the standardized system controllers. The license-free Flexi
offers intuitive programming, rapid com-missioning, and continuous monitoring.
-mented in multiple languages with just one click.
At a glance• Expansion modules, Motion Control
modules, and gateways for all com-
• system plug
• Safe networking of up to 32 Flexi Soft stations
• Integration of sensor cascade• -
operation, plausibility check, simula-tion mode, wiring diagram, parts list, documentation, and data recorder
• optimized safety application solution
• modular structure that is in line with
an ideal level of granularity•
featuring comprehensive functions enables continuous monitoring of the
• -
provides documentation and a wiring diagram
• Safety logic is easy to create thanks
blocks• The main module’s diagnostics inter-
facility in the system plug enable rapid commissioning, component replacement, and troubleshooting, resulting in minimum downtimes
Additional information
Detailed technical data . . . . . . . . . . .17
Ordering information . . . . . . . . . . . . .25
Dimensional drawings . . . . . . . . . . . 26
Accessories. . . . . . . . . . . . . . . . . . . . 28
�� www.mysick.com/en/Flexi_Soft
For more information, just enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples and much more.
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
1 7
SAFETY CONTROLLERS Flexi Soft
Detailed technical data
General data
System construction Modular
System plug 1
Main module 1
Gateways 0 ... 2
Expansion modules 0 ... 12 1)
Relay modules 0 ... 8 2)
Module interconnection Internal bus (FLEXBUS+)
Via software
Flexi Soft Designer
Fieldbus/industrial network CANopen, EtherCAT, EtherNet/IP, MODBUS TCP, PROFIBUS DP, PROFINET, DeviceNet
Via gateway
1) Each Motion Control module connected reduces the possible number of other expansion modules by two.2) Up to 8 UE410-2RO relay output modules and/or 4 UE410-4RO relay output modules (meaning a max. of 16 safe relay outputs).
Main modules
Safety-related parameters
FX3-CPU0 FX3-CPU1 FX3-CPU2 FX3-CPU3
SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category 4 (EN ISO 13849-1)
PL e (EN ISO 13849-1)
1.07 x 10-9 (EN ISO 13849)
1.69 x 10-9 (EN ISO 13849) 1.69 x 10-9 (EN ISO 13849)
0.4 x 10-9 (EN ISO 13849) 1)
TM20 years (EN ISO 13849)
1) Applies for a main module FX3-CPU3 that is used exclusively for routing information via Flexi Line.
Functions
FX3-CPU0 FX3-CPU1 FX3-CPU2 FX3-CPU3
Restart interlock
�
�
– �
Flexi Link – �
Flexi Line – �
– �
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
1 8
Flexi Soft SAFETY CONTROLLERS
Interfaces
FX3-CPU0 FX3-CPU1 FX3-CPU2 FX3-CPU3
System connection System plug FX3-MPL000001 System plug FX3-MPL100001
Connection type
System plug Screw-type terminals
EFI connection – Spring terminals
Flexi Line connection – Spring terminals
Number of EFI interfaces 0 2
RS-232 RS-232, USB
Electrical data
Protection class III (EN 61140)
PELV or SELV 1)
s24 V DC (16.8 V DC ... 30 V DC)
Internal power consumption
II (EN 61131-2)
1) The current of the power supply that powers the main unit must be limited to a maximum of 4 A, either through the power supply itself or a fuse.
Mechanical data
FX3-CPU0 FX3-CPU1 FX3-CPU2 FX3-CPU3
22.5 mm x 96.5 mm x 120.6 mm
111 g (± 5 %) 119 g (± 5 %) 133 g (± 5 %)
Ambient data
Terminals IP 20 (EN 60529)
Housing IP 40 (EN 60529)
–25 °C ... +55 °C
–25 °C ... +70 °C
10 % ... 95 %, non-condensing
EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity)
Class A (EN 61000-6-2, EN 55011)
1 g, 5 Hz ... 150 Hz (EN 60068-2-6)
3 g RMS, 10 Hz ... 500 Hz (EN 60068-2-64)
Continuous shock 10 g, 16 ms (EN 60068-2-27)
Single shock 30 g, 11 ms (EN 60068-2-27)
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
1 9
SAFETY CONTROLLERS Flexi Soft
Gateways
Interfaces
FX0-GENT
FX0- FX0-GPNT
FX0-GETC
FX0-GPRO
FX0-GCAN
FX0-
Fieldbus/industrial network EtherNet/IP MODBUS TCP
PROFINET EtherCAT PROFIBUS DP
CANopen DeviceNet
Integrated device
3-port layer-2 managed switch with Auto-MDI-X for automatic detection of crossed Ethernet cable
–
Connection type 2 x female connector, RJ-45 1 x female connector, D-Sub, 9-pin
1 x female connector, Open Style, 5-pin
Baud rate – MBaud
–
10 Mbit/s (10Base-T)
100 Mbit/s (100Base-TX)
(autosensing)
kbit/s 1)
kbit/s 1)
kbit/s 1)
1) Depending on cable length.
Electrical data
FX0-GENT
FX0- FX0-GPNT
FX0-GETC
FX0-GPRO
FX0-GCAN
FX0-
Protection class III (EN 61140)
Via FLEXBUS+
Internal power consumption 1) 1) 1)
1) Via FLEXBUS+.
Mechanical data
FX0-GENT
FX0- FX0-GPNT
FX0-GETC
FX0-GPRO
FX0-GCAN
FX0-
22.5 mm x 96.5 mm x 120.6 mm 22.5 mm x 96.5 mm x 131 mm
125 g (± 10 %) 150 g (± 10 %)
Ambient data
Terminals IP 20 (EN 60529)
Housing IP 40 (EN 60529)
–25 °C ... +55 °C
–25 °C ... +70 °C
10 % ... 95 %, non-condensing
EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity)
Class A (EN 61000-6-2, EN 55011)
5 g, 10 Hz ... 500 Hz (EN 60068-2-6)
Continuous shock 10 g, 16 ms (EN 60068-2-27)
Single shock 30 g, 11 ms (EN 60068-2-27)
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
2 0
Flexi Soft SAFETY CONTROLLERS
Expansion modules – I/O modules
Safety-related parameters
FX3-XTIO FX0-STIO
SIL3 (IEC 61508)
SILCL3 (EN 62061)
–
Category 4 (EN ISO 13849-1) –
PL e (EN ISO 13849-1) –
4.8 x 10-9 (EN ISO 13849) 1)
0.9 x 10-9 (EN ISO 13849) 2)
0.4 x 10-9 (EN ISO 13849)
–
TM20 years (EN ISO 13849)
1) For single channel outputs.2) For dual channel outputs.
Functions
FX3-XTIO FX0-STIO
Flexi Loop-compatible � –
� –
Fast shut-off time 8 ms –
Interfaces
FX3-XTIO FX0-STIO
Number of safety inputs 8 (I1 – I8) 0
Number of non-safe inputs 0 6-8 (I1 – I6, IY7, IY8) 1)
2 (X1, X2) 8 (X1 – X8) 2 (XY1, XY2) 0
Number of safe outputs 4 (Q1 – Q4) 0
Number of non-safe outputs 0 4-6 (XY1, XY2, Y3 – Y6) 2)
6-8 (Y1 – Y6, IY7, IY8) 1)
Connection type Spring terminals
1) The FX0-STIO has 6 non-safe standard inputs and outputs. In addition the connections IY7 and IY8 can be used both as a standard input and as a standard output.2) In addition the test outputs XY1 and XY2 can be used as further standard outputs.
Electrical data
FX3-XTIO FX0-STIO
Protection class III (EN 61140)
Internal logic Via FLEXBUS+
Test signal outputs Via FLEXBUS+ –
Safe outputs Via A1, A2 –
Non-safe outputs – Via A1, A2
Internal power consumption 1) 1) 1) 2)
1) Via FLEXBUS+, without current on test signal outputs.2) Via FLEXBUS+.
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
2 1
SAFETY CONTROLLERS Flexi Soft
Power supply terminals
FX3-XTIO FX0-STIO
Terminals A1, A2 – A1, A2
PELV or SELV 1) – PELV or SELV 1)
24 V DC (16.8 V DC ... 30 V DC)
– 24 V DC (16.8 V DC ... 30 V DC)
Input current –
1) The current of the power supply that powers the module must be limited to a maximum of 4 A, either through the power supply itself or a fuse.
Safe inputs
FX3-XTIO FX0-STIO
Terminals I1 – I8 –
HIGH 13 V DC ... 30 V DC –
LOW –5 V DC ... 5 V DC –
Input current
HIGH 2.4 mA ... 3.8 mA –
LOW –2.5 mA ... 2.1 mA –
Non-safe inputs
FX3-XTIO FX0-STIO
Terminals – I1 – I6, IY7, IY8
HIGH – 13 V DC ... 30 V DC
LOW – –5 V DC ... 5 V DC
Input current
HIGH – 2.4 mA ... 3.8 mA
LOW – –2.5 mA ... 2.1 mA
FX3-XTIO FX0-STIO
Terminals X1, X2 X1 – X8 XY1, XY2 –
Type of output PNP semiconductors, short-circuit protected –
2 (X1, X2) 2 (X1/X3/X5/X7, X2/X4/X6/X8)
2 (XY1, XY2) –
15 V DC ... 30 V DC –
Output current 1) –
–
Pulse duration –
1) At each of the two test signal generators. This means that a maximum of 8 testable sensor cascades per module with max. 30 mA each are possible.
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
2 2
Flexi Soft SAFETY CONTROLLERS
Safe outputs
FX3-XTIO FX0-STIO
Terminals Q1 – Q4 –
Type of output PNP semiconductors, short-circuit pro-tected, cross-circuit monitoring
–
16 V DC ... 30 V DC –
Output current –
Load capacity –
Non-safe outputs
FX3-XTIO FX0-STIO
Terminals – XY1, XY2, Y3 – Y6 Y1 – Y6, IY7, IY8
Type of output – PNP semiconductors, short-circuit protected
– 16 V DC ... 30 V DC
Output current
XY1, XY2 – –
Y3 – Y6 – –
Y1 – Y6 –
IY7, IY8 –
Mechanical data
FX3-XTIO FX0-STIO
22.5 mm x 96.5 mm x 120.6 mm
164 g (± 5 %) 139 g (± 5 %)
Ambient data
Terminals IP 20 (EN 60529)
Housing IP 40 (EN 60529)
–25 °C ... +55 °C
–25 °C ... +70 °C
10 % ... 95 %, non-condensing
EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity)
Class A (EN 61000-6-2, EN 55011)
1 g, 5 Hz ... 150 Hz (EN 60068-2-6)
3 g RMS, 10 Hz ... 500 Hz (EN 60068-2-64)
Continuous shock 10 g, 16 ms (EN 60068-2-27)
Single shock 30 g, 11 ms (EN 60068-2-27)
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
2 3
SAFETY CONTROLLERS Flexi Soft
Expansion modules – Motion Control modules
Find detailed technical data on page 36.
Safe sensor cascade Flexi Loop
Find detailed technical data on page 30.
Relay modules
Safety-related parameters
SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category 4 (EN ISO 13849-1)
PL e (EN ISO 13849-1)
Interfaces
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Number of control inputs 1 (B1) 2 (B1, B2) 1 (B1, B2)
Number of enable current contacts 2 (13/14, 23/24) 4 (13/14, 23/24, 33/34, 43/44)
2 (13/14, 23/24)
1 (Y14) 2 (Y14, Y24) 0
1 (Y1/Y2) 2 (Y1/Y2, Y3/Y4) 1 (Y1/Y2)
Connection type Spring terminals Plug-in screw-type terminals
Electrical data
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Via FLEXBUS+ Via B1, B2
Internal power consumption
II (EN 61131-2)
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Terminals B1 B1, B2
24 V DC (18 V DC ... 30 V DC) 24 V DC (16.8 V DC ... 27.6 V DC)
Enable current contacts
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Terminals 13/14, 23/24 13/14, 23/24, 33/34, 43/44
13/14, 23/24
Type of output Potential-free NO contacts, positively guided
5 V AC/DC ... 253 V AC/DC 10 V AC/DC ... 250 V AC/DC
10 mA ... 6 A
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Terminals Y14 Y14, Y24 –
Type of output NO contact, connected to internal 24 V DC, positively guided, current-limited
–
24 V DC (16 V DC ... 30 V DC) –
Output current –
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
2 4
Flexi Soft SAFETY CONTROLLERS
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Terminals Y1/Y2 Y1/Y2, Y3/Y4 Y1/Y2
Type of output Potential-free NC contacts, positively guided
5 V AC/DC ... 253 V AC/DC 0.1 V AC/DC ... 60 V AC/DC
10 mA ... 6 A 1 mA ... 300 mA
Mechanical data
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
22.5 mm x 96.5 mm x 120.6 mm 17.8 mm x 105.5 mm x 70.8 mm
160 g (± 5 %) 186 g (± 5 %) 91 g (± 5 %)
Ambient data
UE410-2RO4 UE410-4RO4 UE10-2FG3 UE12-2FG3
Terminals IP 20 (EN 60529)
Housing IP 40 (EN 60529)
–25 °C ... +55 °C 0 °C ... +55 °C
–25 °C ... +70 °C –25 °C ... +75 °C
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
2 5
SAFETY CONTROLLERS Flexi Soft
Ordering information
Main modules
Number of EFI interfaces
Flexi Link Automatic Flexi Line Type Part no.
0 – – – FX3-CPU000000 1043783
2 �
– – FX3-CPU130002 1043784
�
– FX3-CPU230002 1058999
� FX3-CPU320002 1059305
Gateways
Fieldbus/industrial network Type Part no.
EtherNet/IP FX0-GENT00000 1044072
MODBUS TCP FX0-GMOD00000 1044073
PROFINET FX0-GPNT00000 1044074
EtherCAT FX0-GETC00000 1051432
PROFIBUS DP FX0-GPRO00000 1044075
CANopen FX0-GCAN00000 1044076
DeviceNet FX0-GDEV00000 1044077
Expansion modules – I/O modules
Flexi Loop-compatible
Number of safe inputs
Number of non-safe
inputs
Number of
outputs
Number of safe outputs
Number of non-safe outputs
Type Part no.
� 8 0
2 4 0 FX3-XTIO84002 1044125
8 0 0 FX3-XTDI80002 1044124
2 0 4-6 FX3-XTDS84002 1061777
– 0 6-8 0 0 6-8 FX0-STIO68002 1061778
Expansion modules – Motion Control modules
Type Part no.
Flexi Soft Drive Monitor FX3-MOC00000 1062344
Safe sensor cascade Flexi Loop
Flexi Loop node for safety sensors with dual-channel OSSD outputs
Connection type Number of non-safe inputs Number of non-safe outputs Type Part no.
Female connector M12, 5-pin 1 0 FLN-OSSD1000105 1061709
Female connector M12, 8-pin 1 1 FLN-OSSD1100108 1061710
Connection type Number of non-safe inputs Number of non-safe outputs Type Part no.
Female connector M12, 5-pin 0 0 FLN-EMSS0000105 1061711
Female connector M12, 8-pin 1 1 FLN-EMSS1100108 1061712
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
2 6
Flexi Soft SAFETY CONTROLLERS
Flexi Loop power supply module
Type Part no.
The power supply module is used to connect a power supply with 24 V DC, for the electrical isolation and for overcurrent shutdown.
FLA-PWRI00001 1061715
Flexi Loop terminator module
Type Part no.
The terminator is used to terminate the safe sensor cascade on the last Flexi Loop node. FLT-TERM00001 1061716
Relay modules
Number of enable current contacts contacts
Number of contactor Type Part no.
2 1 1 UE410-2RO4 6032677
4 2 2 UE410-4RO4 6032676
2 0 1UE10-2FG3D0 1043916
UE12-2FG3D0 1043918
Dimensional drawings (Dimensions in mm (inch))
FX3-CPU0, FX3-CPU1, FX3-CPU2, FX3-CPU3
����������
����������
��������
����������
��
���
����
�
��
��
����������
������������
������
����������
���
�����������
����������
���������
�����������
��
��
��
���
���
���
FX3-XTIO, FX3-XTDI, FX3-XTDS, FX0-STIO, UE410-2RO4, UE410-4RO4
����������
�����������
��
���
���
���
��
��
����������
����������
��������
����������
����������
�����������
�����������
�����������
���������
�� �
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
2 7
SAFETY CONTROLLERS Flexi Soft
FX0-GENT, FX0-GMOD, FX0-GPNT, FX0-GETC
��������
��������
���������
��
� �
��
��
��
�� ��
���
���
��
���
����������
���������
����������
��
��
��
��
��
��
FX0-GPRO, FX0-GCAN, FX0-GDEV
��������
��������
���������
��
�� ��
�
��
��
��
��
����������
��
���
��
�
��
���
��
�
������������
�������������
�������������
�������������
�������������
UE10-2FG3, UE12-2FG3
���������
����������
��
���
��
��
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K 8012805/2014-01-23
Subject to change without notice
2 8
Flexi Soft SAFETY CONTROLLERS
Accessories
Plug connectors and cables
System plugs
Specialty Type Part no.
without EFI-compatible devices
For FX3-CPU0 and FX3-CPU1 FX3-MPL000001 1043700
including EFI-compatible devices via For FX3-CPU2 and FX3-CPU3 FX3-MPL100001 1047162
Connecting cable (male connector-open)
Type Part no.
Connector, M8, 4-pin, angled Open conductor heads 3 m Connection cable 6036342
Connection cable (male-female connector)
Type Part no.
Connector, M8, 4-pin, straight
Female connector, D-Sub, 9-pin, straight
2 m DSL-8D04G02M025KM1 6021195
10 m DSL-8D04G10M025KM1 2027649
Connection cable (male connector-male connector)
Type Part no.
Connector, M8, 4-pin, straight
Connector, USB-A, straight
2 m DSL-8U04G02M025KM1 6034574
10 m DSL-8U04G10M025KM1 6034575
Connector, USB-A, straight
Connector, Mini-USB, straight
3 m Connection cable 6042517
Cable (open-open)
Items supplied Type Part no.
Open conductor heads Open conductor heads By the meter
Flexi Link cable 6034249
EFI connecting cable 6029448
Male connector (ready to assemble)
Connection type Permitted cross-section Type Part no.
Terminal connector, 4-pin
Screw-type terminal connector
2045891
Spring terminal connector
2045890
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
s e n s : C o n t r o l – S A F E C O N T R O L S O L U T I O N S | S I C K8012805/2014-01-23
Subject to change without notice
2 9
SAFETY CONTROLLERS Flexi Soft
Adapters/distributors
Other adapters/distributors
Type Part no.
Diode module, for the connection of multiple short-circuiting switching mats (up to 4) DM8-A4K 6026142
Power supply units/power cord connectors
Output current Type Part no.
100 V AC ... 240 V AC 24 V DC
Power supply 7028789
Power supply 7028790
Muting accessories
Connection type Type Part no.
Illustration may differ
LED muting lamp, inclusive mounting kit,
inclusive connection cableCable with connector M12
2 m Indicator lamp 2019909
10 m Indicator lamp 2019910
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T