6
product NEW No, NPPDF7-01E Digital Pressure Gauge GPD Compact body Dust and water proof : IP65 Pressure value is shown on easily viewable digital display. A power saving mode is included. Battery life is about 3 years. Visible indication of battery change time Rich option parts Body size : Width 30 mm and height 30 mm IP65 can be maintained by operation with a tube in air release port. (See page 4) Easy to check by reading the value on the display. One touch to indicate pressure value. The battery life is expected when pressure value displayed at 5 times a day basis. Battery level indicator blinks to notify when battery level becomes low. With a flat-blade screwdriver (width 1.4mm), battery can be easily replaced. Battery level indicator Panel adapter set Upright bracket Wall bracket Type : ACPG-31-P1 (a+b), ACPG-31-P2 (a+b+c) Type : ACPG-31-B1 Type : ACPG-31-B2 a. Front panel adapter b. Back panel adapter c. Front protective cover

product Digital Pressure Gauge - PISCOen.pisco.co.jp/media/book_en/NPPDF7-01E.pdfproduct NEW No, NPPDF7-01E Digital Pressure Gauge GPD Compact body Dust and water proof : IP65 Pressure

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

product

NEWNo, NPPDF7-01E

Digital Pressure GaugeGPD

Compact body Dust and water proof : IP65

Pressure value is shown on easily viewable digital display.

A power saving mode is included. Battery life is about 3 years.

Visible indication of battery change time

Rich option parts

Body size : Width 30 mm and height 30 mm IP65 can be maintained by operation with a tube in air release port. (See page 4)

Easy to check by reading the value on the display.

One touch to indicate pressure value. The battery life is expected when pressure value displayed at 5 times a day basis.

Battery level indicator blinks to notify when battery level becomes low.With a flat-blade screwdriver (width 1.4mm), battery can be easily replaced.

Battery level indicator

■Panel adapter set■Upright bracket■Wall bracket

Type : ACPG-31-P1 (a+b), ACPG-31-P2 (a+b+c)

Type : ACPG-31-B1 Type : ACPG-31-B2

a. Front panel adapter

b. Back panel adapter

c. Front protective cover

2

2013 NEW PRODUCTS

(1).Pressure gauge(2).Specification

Code DSpecification Digital indication(3).Output spec.

Code V No codeSpecification Negative pressure (-101 ~ 0kPa) Positive pressure (0.000 ~ 1.000MPa)(4).Connection type & size

Code 01Type &

sizeOuter dia.: Taper male thread R1/8

Inner dia. : Metric female thread M5×0.8

(1).ModelACPG-31:Digital Pressure Gauge Accessories

(2).Accessory typesCode B1 B2 P1 P2

Type Bracket(Wall bracket and 2 pcs. of M3x5 male thread)

Bracket(Upright bracket and 2 pcs. of M3x5 male thread)

Panel adaptor set without front protective cover(Front panel adaptor and Back panel adaptor)

Panel adaptor set with front protective cover(Front protective cover, Front panel adaptor and Back panel adaptor)

GP(1)

ACPG-31(1)

D(2)

B1(2)

V(3)

01(4)

━━

Model GPD-V-01 (For negative pressure) GPD-01 (For positive pressure)Rated pressure range -101~0kPa 0.000~1.000MPaPressure display range -101~10kPa(*3) -0.100~1.000MPa(*1, *2)Proof pressure 300kPa 1.5MPaFluid type Air, Non-corrosive/non-inflammable gasesBattery CR2032 Lithium battery (*5)Battery life Approximately 3 years (5 times indication /day)Min. battery level monitor IncludedReplacement of batteries PossibleIndication time length 60 sec. after pushing the buttonSampling rate 2Hz (2 times/sec)Repeatability ≦±1% F.S. ±1 digit ≦±0.2% F.S. ±1 digitLCD display 7 segment display, 3.5 digitIndication accuracy ±2%F.S. ±1digit or less (Ambient temp. : 25±3ºC)Protective structure IP65(*4)Ambient temperature limits At operation: 0~50ºC , At storage : -10~60ºC (No dew condensation and no freezing)Ambient humidity limits At operation and storage : 35~85%RH (No dew condensation)Vibration resistance Total amplitude is 1.5mm or 100m/s2, 10Hz~55Hz~10Hz for 1min., 2 hours each direction of X, Y, and ZShock resistance 100m/s2 3 times each direction of X, Y, and ZTemprature characteristics ±2%F.S. of detected pressure (at 25ºC)*1. Figure 1 & 2 show indications when negative pressure is applied on GPD-01.*2. The range from -0.1to 0Mpa is beyond guaranteed range of indication accuracy for GPD-01.*3. The range from 0 to 10kPa is beyond guaranteed range of indication accuracy for GPD-01.*4. Make sure to use with a tube inserted in the air release port (Figure 3) to maintain IP65.*5. Use of a designated battery, otherwise it may cause fire or an electric shock.*6. No calibration is included in after-sales service.

Digital Pressure Gauge

Digital Pressure Gauge Accessories

Figure 1 Figure 3

Air release port

Tube

Figure 2

Specif ication

Model designation (Example)

Model designation (Example)

3022.515.5

6

21.8 20

20

37

Hex.12R1/8

309

2-M3x0.5

M5x0.8Depth : 7

29.520

4-ø4

1.613

20

206

12.4

45

4.2

20 31

5

■Front panel adapter ■Panel cutout dimension

■Back panel adapter

Panel thickness : 0.5~4.5mm

+0-0.4434.4 □31

3330.2

34.4

33 30.2

■Front protective cover

■Front panel adapter

■Back panel adapter

■Panel cutout dimension34.4 8.5

4

34.4

34.4

3330.2

34.4

33 30.2

Panel thickness : 0.5~4.5mm

+0-0.4□31

29.5 20

45

1.6

2020

20

20

12 5

4.2

4-ø4

3

Digital Pressure Gauge

GPD-V-01 Negative pressure type

GPD-01 Positive pressure type

Unit : mm

Model designation Weight(g)

GPD-V-01 37GPD-01 37

ACPG-31-B1 Wall bracket

ACPG-31-P1 Panel adaptor set ACPG-31-P2 Panel adaptor set with front protective cover

ACPG-31-B2 Upright bracket

Unit : mm

Model designation Weight(g)

ACPG-31-B1 10

Unit : mm

Model designation Weight(g)

ACPG-31-P1 4

Unit : mm

Model designation Weight(g)

ACPG-31-P2 5

Unit : mm

Model designation Weight(g)

ACPG-31-B2 12

●Digital Pressure Gauge Accessories

Outer dimension

No pushing the button for 60 sec. or 120 sec.

4

2013 NEW PRODUCTS

[ How to attach accessories ]

[ Panel indication spec. ]

[ Zero point adjustment mode ]

Push button for 2 to 5 sec. at measurement mode

Release the button

* Make sure to set pressure supply port status of exhaust to air before adjust zero point.

After indication of " ", release button.

●How to attach a bracket ●Measurement mode

●Measurement mode

●Zero point adjustment mode

●How to attach a panel adapter set

Wall bracket(ACPB-31-B1)

Upright bracket(ACPB-31-B2)

ACPB-31-P1ACPB-31-P2

Battery level

BracketGaugebody

Pressure gauge

Back panel adaptor

Front panel adaptorFront protective cover

Gaugebody

M3x0.5 Male thread(Accessary)

M3x0.5 Male thread(Accessary)

Bracket

Pressure indication

Button

GPD-V-01(For negative pressure)

GPD-01(For positive pressure)

[ Power saving mode ]

[ Instruction to maintain IP65. ]

1.When button is not pushed for 60 sec., the mode will be switched to the power saving automatically.

2.Pushing button at measuring mode can extend display time length to 120 sec.

1.Insert a tube ( outer dia. ø4mm, inner dia. dia., ø2.5mm) in the air release port to maintain IP65.

2.Select tube length to meet user's required environment.

Measurement mode Power saving mode

Tube

Air release port

[ Indication of error ]Error name Indication Description Treatment

Residual pressure error

More than ±3%F. S. residual pressure is detected when adjusting zero point.

Return the impressed pressure to atmospheric pressure level and try to adjust zero point again.

Operation pressure error

Impressed pressure is over maximum limit of rated pressure range. Adjust impressed pressure within rated

pressure range.Impressed pressure is less than minimum limit of rated pressure range.

Battery level error Battery level is less than 2.4V. Replace batteries.

Operation procedures & Function description

Less than 2 mm

5

Digital Pressure Gauge

[ Battery replacement procedures ]

1.When battery level becomes low, battery level indicator blinks.

*1.Pay attention not to get foreign particles and fluff inside.*2.Zero point returns to the factory default value after replacement of batteries.

7.Finally, set the back panel and battery replacement is completed.

6.Check the battery polarity and insert a new battery.

5.Using a stick-like tool with ø less than 2mm to take out the old battery.

4.Pull out the back panel.

3. Insert the flat-blade screwdriver in the side of the back panel to release the notch completely.Do the same thing on the other side and release the notch.

2. Insert a flat-blade screwdriver (size 1.4mm x 3mm) in the slot on back panel and turn it by 90 degree to release the notch.

: 1. This product must not be used in gas or liquid where a corrosive substance is dissolved.

2. Never use this product beyond the specification range. Using it beyond the specification range causes troubles, damage, and significant decrease in battery life.

3. This product is not designed to be explosion-proof. Do not use it in the environment where corrosive or explosive gas exists.

Warning

: 1. When handling this product, do not drop it, hit it or give strong shock to it. The inside of the product may get damaged while there seems to be no damage by appearance.

2. Do not use the product where oil drop may fall. Besides, if there is a possibility that water or dust may get inside of the body from air release port, insert a tube in the air release port and extend it enough so that the other side can be placed at a safe place where no water fall is expected. In this procedure, make sure not to bent the tube or close its end.

3. When using this product, an air filter should come just before it.

4. Make sure to use this product with the air release port in the status of exhaust to air.

Cautions

Detailed Safety Instructions

2013 NEW PRODUCTS

● The specifications are subject to change without advance notice. 2013.12.PDF

OVERSEAS MARKETING DEPARTMENT3884-1 MINAMIMINOWA, KAMIINA, NAGANO-PREF., 399-4588 JAPANTEL : +81-(0)265-76-7751  FAX : +81(0)265-76-3305URL : en.pisco.co.jp/   E-mail : [email protected]