1
www.jinkosolar.com TYPEPV-JK03M ISO9001:2008ISO14001:2004OHSAS18001 certified factory. TUV Rheinland, UL certified products Engineering Drawing Technical Parameters Front Back Back Front The company reserves the final right for explanation on any of the information presented hereby. PV-JK03M_rev2016 <0.5 mΩ Overvoltage Category Pollution Degree Protection Class Electrical Characteristics Rated Voltage 1000VDC / 1500VDC (UL) Rated Impulse Voltage Rated Insulation Voltage 12000V / 16000V 6000V / 8000V Test Voltage 6KV / 8KV (50H,1min) Rated Current (IEC 85) 20A (UL) Contact Resistance Other Characteristics UL94 5VA(UL) From -40 to +85 100 UL1703 & UL6703 Flame Class Ambient Temperature Wire cross section area or cross section range Operating Cycles Reference Standard Upper limit Temperature 100 2 Class II Mechanical Characteristics CAT III Insulation Material IP Rating Cable Type Dimensions Female Dimensions Male Bendings Radius Termination and Connection Conducter Material PPE + PA IP67 63.30mm*17.46mm ≥ 4 * Cable OD Crimped Connection 66.10mm*19.80mm Copper,tin plated 66.10 63.30 19.80 17.46 Model of PV Connector: PV-JK03M 1.00-1.50 1.00-1.50 Product Datasheet of connector 12AWG / 10AWG 1*4.0mm²;1*6.0mm² * 1500V Avaliable

Product Datasheet Model of PV Connector: PV-JK03M of connector · Model of PV Connector: PV-JK03M 1.00-1.50 1.00-1.50 Product Datasheet of connector 12AWG / 10AWG 1*4.0mm²;1*6.0mm²

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Datasheet Model of PV Connector: PV-JK03M of connector · Model of PV Connector: PV-JK03M 1.00-1.50 1.00-1.50 Product Datasheet of connector 12AWG / 10AWG 1*4.0mm²;1*6.0mm²

www.jinkosolar.com

TYPE:PV-JK03M

ISO9001:2008、ISO14001:2004、OHSAS18001certified factory.TUV Rheinland, UL certified products

Engineering Drawing Technical Parameters

Front Back Back Front

The company reserves the final right for explanation on any of the information presented hereby. PV-JK03M _rev2016

<0.5 mΩ

Overvoltage Category

Pollution Degree

Protection Class

Electrical Characteristics Rated Vol tage 1000VDC / 1500VDC (UL)

Rated Impulse Vol tage

Rated Insulat ion Vol tage

12000V / 16000V

6000V / 8000V

Test Vol tage 6KV / 8KV (50Hz,1min)

Rated Current (IEC 85℃) 20A (UL)

Contact Resistance

Other Characteristics

UL94 5VA(UL)

From -40℃ to +85℃

100

UL1703 & UL6703

Flame Class

Ambient Temperature

Wire cross sect ion area or crosssect ion range

Operat ing Cycles

Reference Standard

Upper l imi t Temperature 100℃

2

Class I I

Mechanical Characteristics

CAT I I I

Insulation Material

IP Rating

Cable Type

Dimensions Female

Dimensions Male

Bendings Radius

Termination and Connection

Conducter Material

PPE + PA

IP67

63.30mm*17.46mm

≥ 4 * Cable OD

Crimped Connection

66.10mm*19.80mm

Copper,tin plated

66.10 63.30

19.8

0

17.4

6

Model of PV Connector: PV-JK03M

1.00-1.50

1.00-1.50

Product Datasheet of connector

12AWG / 10AWG

1*4.0mm²;1*6.0mm²

* 1500V Avaliable