1
PRODUCT DATASHEET KEV HEATSHRINK GLOVES / BOOTS Catalogue Pre Shrink After Shrink Wall Thickness No. Fingers Dimensions (mm) Dimensions (mm) Pre Shrink (mm) A B C D A1 B1 C1 D1 (mm) 2 OUTLETS KEV2/1 2 30 14 70 15 12 4.5 93 23 2.2 KEV2/3 2 60 25 - 34 23 7.5 118 29 3.2 3 OUTLETS KEV320 3 38 14 75 15 16 4.5 110 35 2.2 KEV330 3 60 25 160 53 25 8 165 50 3.7 KEV335 3 80 35 180 60 38 11 185 55 4.3 KEV340 3 110 46 205 70 50 17.5 250 65 3.8 4 OUTLETS KEV410 4 28 9 - 17 9 1.8 78 - 2.0 KEV420 4 40 14 84 15 15 3.5 105 26 2.4 KEV430 4 55 20 140 32 21 5 150 40 3.5 KEV440 4 75 28 158 34 26 7 175 45 3.7 KEV445 4 82 30 190 36 37 9 190 60 3 KEV450 4 90 32 175 38 37 9 190 60 3.7 KEV455 4 102 38 190 40 47 12 198 58 3 KEV460 4 130 52 175 40 52 15 240 75 3.7 KEV Heatshrink Gloves (boots) are used to seal and waterproof cable terminations, by sealing the insulated conductors to the cable jacket. They have a hot melt glue liner which melts while the glove is shrinking and creates a strong bond between the glove and the cable. • Quick and simple installation of waterproof termination • High resistance to tearing and high tensile strength • Resistant to decay, chemicals and corrosion To select a glove, measure the outside diameter of the cable and order the next size up by checking dimension ‘A’ in the accompanying table. To install the glove, ensure that the insulation of the cable and conductor are clean and grease free, and roughen with emery paper for a good glue bond. Shrink the glove from the middle out with a heatgun or soft yellow gas flame until adhesive extrudes. Avoid local overheating during shrinkage process. 2 WAY KEV 2/1-2/3 A-A 1 3 WAY KEV 3/1-340 B 1 B A-A 1 4 WAY KEV 410-450 A-A 1 C-C B 1 B B 1 B D-D1 C-C1 D-D1 C-C1 D-D1 2 WAY KEV 2/1-2/3 A-A 1 3 WAY KEV 3/1-340 B 1 B 4 WAY KEV 410-450 A-A 1 C-C1 B 1 B B 1 B D-D1 C-C1 D-D1 C-C1 D-D1 2 WAY KEV 2/1-2/3 A-A 1 3 WAY KEV 3/1-340 B 1 B 4 WAY KEV 410-450 A-A 1 C-C1 B 1 B B 1 B D-D1 C-C1 D-D1 C-C1 D-D1 Technical Data Conformant Standards DIN: VDE: IEC Material Modified cross-linked polyolefin Continuous Operating Temp -40°C to +110°C Shrinkage Temp Tensile Strength Ultimate Elongation Longitudinal Shrinkage Breakdown Voltage Volume Resistivity Water Absorption Flammability UV Resistance Heat Shock Starts 105°C, completed 125°C 12 MPa (ASTM D 2671) 200% min 10% 16 kV/mm wall thickness 1.0 x 10 14 ohm cm minimum 0.5% Do not use KEV in flame prone areas Passed - ISO 1408 225°C for 4 hours

PRODUCT DATASHEET - CABAC€¦ · kev2/1 2 30 14 70 15 12 4.5 93 23 2.2 kev2/3 2 60 25 -34 23 7.5 118 29 3.2 3 outlets kev320 3 38 14 75 15 16 4.5 110 35 2.2 kev330 3 60 25 160 53

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRODUCT DATASHEET - CABAC€¦ · kev2/1 2 30 14 70 15 12 4.5 93 23 2.2 kev2/3 2 60 25 -34 23 7.5 118 29 3.2 3 outlets kev320 3 38 14 75 15 16 4.5 110 35 2.2 kev330 3 60 25 160 53

PRODUCT DATASHEET

KEV HEATSHRINK GLOVES / BOOTS

Catalogue Pre Shrink After Shrink Wall Thickness No. Fingers Dimensions (mm) Dimensions (mm) Pre Shrink

(mm) A B C D A1 B1 C1 D1 (mm)2 OUTLETS KEV2/1 2 30 14 70 15 12 4.5 93 23 2.2KEV2/3 2 60 25 - 34 23 7.5 118 29 3.2

3 OUTLETSKEV320 3 38 14 75 15 16 4.5 110 35 2.2KEV330 3 60 25 160 53 25 8 165 50 3.7KEV335 3 80 35 180 60 38 11 185 55 4.3KEV340 3 110 46 205 70 50 17.5 250 65 3.8

4 OUTLETSKEV410 4 28 9 - 17 9 1.8 78 - 2.0KEV420 4 40 14 84 15 15 3.5 105 26 2.4KEV430 4 55 20 140 32 21 5 150 40 3.5KEV440 4 75 28 158 34 26 7 175 45 3.7KEV445 4 82 30 190 36 37 9 190 60 3KEV450 4 90 32 175 38 37 9 190 60 3.7KEV455 4 102 38 190 40 47 12 198 58 3KEV460 4 130 52 175 40 52 15 240 75 3.7

KEV Heatshrink Gloves (boots) are used to seal and waterproof cable terminations, by sealing the insulated conductors to the cable jacket. They have a hot melt glue liner which melts while the glove is shrinking and creates a strong bond between the glove and the cable.

• Quick and simple installation of waterproof termination

• High resistance to tearing and high tensile strength

• Resistant to decay, chemicals and corrosion

To select a glove, measure the outside diameter of the cable and order the next size up by checking dimension ‘A’ in the accompanying table.

To install the glove, ensure that the insulation of the cable and conductor are clean and grease free, and roughen with emery paper for a good glue bond. Shrink the glove from the middle out with a heatgun or soft yellow gas flame until adhesive extrudes. Avoid local overheating during shrinkage process.

2 WAYKEV 2/1-2/3

A-A1

3 WAYKEV 3/1-340

B1BA-A1

4 WAYKEV 410-450

A-A1

C-C1

B1B

B1B

D-D1

C-C1D-D1

C-C1D-D1

2 WAYKEV 2/1-2/3

A-A1

3 WAYKEV 3/1-340

B1BA-A1

4 WAYKEV 410-450

A-A1

C-C1

B1B

B1B

D-D1

C-C1D-D1

C-C1D-D1

2 WAYKEV 2/1-2/3

A-A1

3 WAYKEV 3/1-340

B1BA-A1

4 WAYKEV 410-450

A-A1

C-C1

B1B

B1B

D-D1

C-C1D-D1

C-C1D-D1

Technical DataConformant Standards DIN: VDE: IECMaterial Modified cross-linked polyolefinContinuous Operating Temp -40°C to +110°CShrinkage Temp Tensile Strength Ultimate Elongation Longitudinal Shrinkage Breakdown Voltage Volume Resistivity Water Absorption Flammability UV Resistance Heat Shock

Starts 105°C, completed 125°C12 MPa(ASTM D 2671) 200% min10%16 kV/mm wall thickness1.0 x 1014 ohm cm minimum0.5%Do not use KEV in flame prone areas Passed - ISO 1408225°C for 4 hours