6 JA
NU
ARY
202
0
www.amvicsystem.com
BUILD TO A HIGHER STANDARD
501 McNicoll Avenue Toronto, ON, CA, M2H 2E2
Toll Free: 1 (877) 470-9991 • Fax: (416) 759-7402
PRODUCT DATA SHEET THERMOQUIETPR
O02
87
Thermal Acoustic Underlay
SOUND ATTENUATION
Amvic Advantage
• Includes a built-in lip and tape for fast and easy joint connections.
• Rolls out flat and straight for easy large installs.
• Can be used under electric mesh radiant heat systems or in conjunction with low profile radiant PEX pipe lock-down panels.
• Composite construction with flame retardant additive.
• Does not promote growth of mold and mildew.
• Acts a thermal break, reducing heat flow across the assembly.
• Metalized film surface acts as a vapor barrier with lip and tape for full continuity.
• Can be installed in ceilings and walls for additional sound attenuation.
Thermoquiet is an acoustic floor underlay which provides acoustic and thermal properties. It can be used for both residential and commercial applications under various finished flooring including, but not limited to, carpet, engineered or solid hardwood, vinyl plank, tile and laminate flooring.
Thermoquiet can be installed using single or double face glue, double sided carpet tape, stapled or floated over wood or concrete surfaces. Its optimized multi-layer construction including dual density foam providing superior comfort and durability.
www.amvicsystem.com
BUILD TO A HIGHER STANDARD
PRO
0287
PRODUCT DATA SHEET THERMOQUIET
Applications• Above residential wood subfloor• Below residential wood floor
joists (basement ceiling)• Low profile retrofit for basement
concrete floor• Main and second floor low
profile hydronic applications• Residential walls and home
theatre applications• Multi-story wood residential
with self-leveling cement floors• Partition/demising walls in
stacked townhouses and multi-story wood residential
• Multi-unit residential buildings with concrete floors
• Commercial walls, floors and ceilings in offices
Installation Details• Wood surface: staple every 4’
(1219mm) on center to stabilize and stretch.
• Concrete surface: glue or double side tape every 4’ (1219mm) on center to stabilize and stretch.
• Remove all folds and wrinkles when stabilizing. Do not overlap layers.
• Thermoquiet is installed with the metalized side facing down.
• Product not to be used above radiant floor heating.
Planks
Planks can be floated, nail or glue down. Solid hardwood is not suitable for basement applications.
Tile
Requires use of adhesive mortar (thinset cement), 3/4” (19mm) trowel with a minimum of 1/2” (13mm) clear mortar.
Carpet
Stretch in or glue down (direct or double glue down).
Physical Properties TableReduction of Impact Sound1
Thermal Resistance2
Roll Length
Roll Area Coverage
Roll Weight
CaseWeight
Gaylord/Pallet Weight
TQ100B35 ∆IIC 20 0.67 F.ft2.hr/Btu
(0.12 m2K/W)
25.0ft
(7.62m)
100ft2
(9.29m2)
4.5lb
(2.04kg)
9 → 55lb
9 → (24.95kg)
36 → 250lb
36 → (113kg)
TQ250B35 ∆IIC 20 0.67 F.ft2.hr/Btu
(0.12 m2K/W)
62.5ft
(19.05m)
250ft2
(23.22m2)
12lb
(5.44kg)
4 → 62lb
4 → (28.12kg)
16 → 270lb
16 → (122kg)
TQ500B35 ∆IIC 20 0.67 F.ft2.hr/Btu
(0.12 m2K/W)
125ft
(38.10m)
500ft2
(46.45m2)
24lb
(10.89kg)
6 → 225lb
6 → (102kg)Thermoquiet is 10/64” (4mm) thick by 48” (1291mm) wide. 1 As tested for ASTM E2179, 6” (152mm) concrete slab floor - ceiling assembly2 As tested for ASTM C518
See Thermoquiet Installation Guide for detailed installation instructions.